Loading...
HomeMy WebLinkAbout749 MAGNOLIA AVE; ; FPR2019-0004; Permit(_City of Carlsbad Print Date: 12/14/2021 Job Address: 749 MAGNOLIA AVE. CARI.SBAD, CA 92008-3061 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: 2042804402 Track #: Valuation: $0.00 Lot # Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2019-0004 Status: Closed - Finaled Applied: 01/10/2019 Issued: 03/19/2019 Finaled Close Out: 12/14/2021 Inspector Final Inspection: Project Title: Description: TMS HIGHLAND INVESTMENTS LLC -NEW SPRINKLER MONITORING FOR BLDGS A, B, & C Applicant: FPContractor: BAY ALARM COMPANY BAY ALARM COMPANY DAN ANDERSON 8205 RONSON RD, #STE F 8205 RONSON RD, # STE F SAN DIEGO, CA 92111-2014 SAN DIEGO, CA 92111-2014 (858) 586-3803 (618) 718-0186 FEE AMOUNT FIRE Sprinkler Monitoring $383.00 - Total Fees: $383.00 Total Payments To Date: $383.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I I I I 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 FfK2-()19 -0004 PROTECTED PREMISE TMS HIGHLAND INVESTMENTS LLC BLDG A 749 MAGNOLIA AVE CARLSBAD, CA 92008 MONITORING COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-470-1000 California Alarm Operating License Number: ACO28 I I I EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 92111 1(800)470-1000 Contractor License # 880138 I I I I 1 DMP.COM 0 0 0 0 0 0 @DMPALARMS XR150F(/XR55OF( FAR FEATURES Up to 562 two-wire smoke detector or fire initiating zones on XR550F( Up to 142 two-wire smoke detector or fire initiating zones on XR150FC Up to .5 Amps 12 VDC smoke and auxiliary output with OV( protection Up to .1 Amps 12 VDC supervised bell output Up to 506 fully programmable Form C relays Serial 3 Digital Dialer or (ID reporting to multiple receivers Eight communication paths between the panel and central station Built-in remote or on-site firmware upgrade capability 12,000 event buffer French, Spanish and English menus available Multiple onboard status LEDs Up to 100 output schedules to control relays and panel outputs 32 individual reporting areas with common areas Built-in 32-character LED annunciator on panel door Output groups deliver maximum functionality with easy programming Onboard Network Onboard 10/100 autosensing Ethernet or Wi-Fi connection Customizable check-in time and retry time Suitable for multi-site applications DMP.COM 0 0 0 0 0 0 @DMPALARMS XR150FC AND XR550FC FIRE PANELS The XR150DFC and XR550DFC provide basic fire monitoring for any single site application. The XR150DNFC and XR550DNFC panels provide all the same basic fire monitoring as the XR150DFC and XR550DFC, enhanced by the onboard Ethernet connection that allows the use of Network MonitoringTM. Both panels come fully assembled from the factory with the following components: Control Panel The XR150FC and XR550FC Series addressable fire panels provide complete system control for local NAC operation. Additionally, DACT, NET, or Cell communication to the central station are provided. The microprocessor-based panel also provides input for Class A zone expansion, conventional and addressable smoke detectors, pull stations, and heat detectors. Keypad Annunciator The Fire Command Center mounted in the door offers a 32-character full text LCD readout that displays system events and menu prompts, making it efficient and easy to use. Transformer and Enclosure The 16 VAC, 56 VA wire-in transformer is factory installed and features a built-in PTC for power circuit protection. FLEXIBLE COMMUNICATION The XR150/XR550 Series of commercial fire panels has transitioned from dialer-focused communications to a true network and cellular communications approach by providing stronger, multi-layered panel communications that ensure a constant link between the panel and central station. The unique DMP Serial 3 format supports 16 or 32-character users, zone and area names to decrease the central station response time and limit dependence on automation literal tables for message conversion. REMOTE ANNUNCIATOR Install up to eight 630F remote annunciators to meet the requirements of virtually any installation. NETWORK OR CELLULAR COMMUNICATION Built-in 10/100 auto-sensing Ethernet connection enhances both standard and encrypted line security options. Both UDP and TCP are supported. The network option can be used as the primary or backup path to the digital diaIe or cellular option. The XR150FC and XR550FC Series panels may be used with the 263 Series Cellular Communicators as the primary path (no backup required) for commercial fire installations. The check-in and fail time settings are programmed for five minutes. As the backup path, the 263 communicator provides the security of a communication link that continues to function, even when landlines are cut or compromised. The communicators can be used as a stand-alone communicator without the need for a backup. This interface works over a variety of carriers in the USA and Canada. EIGHT COMMUNICATION PATHS Configure up to eight communication paths between the panel and central station. Each path has its own panel communication programming parameters, and can be identified as either primary or backup. This enables installers to configure a reliable communication link, offering greater confidence that the panel will always be connected to the central station. COMMUNICATION FUNCTION DIAGNOSTICS The enhanced diagnostic menu enables technicians to check network and cellular communication status, cell signal strength, and e-mail status from the keypad. 12,000 EVENT MEMORY Allows the user to view the last 10,000 door accesses or 2,000 system events that occurred over the past 45 days. FIRE ZONE PROGRAMMING Program zones for fire, fire verify, fire retard, presignal, cross zoning, or fire supervisory. This flexibility allows the ability to match individual zone characteristics to the needs of any area in the fire installation. ZONE EXPANSION The XR150FC and XR550FC provide up to 574 zones, programmable for a variety of fire applications. The system provides Class B 12 VDC powered zones, two on board and four on the 715 Module, plus eight panel burglary zones. Up to 64 zones are available on 16 keypad addresses, and up to 100 zones are available on each built-in LX-Bus using expansion modules. FIRE VERIFY This is used primarily for smoke detector circuits to verify the existence of an actual fire condition. When a Fire Verify zone initiates an alarm, the panel performs a Sensor Reset. If any Fire Verify zone initiates an alarm within 120 seconds after the reset, an alarm is indicated. If an alarm is initiated after another 120 seconds, the cycle is repeated. NOTIFICATION CIRCUIT EXPANSION Easily add NAC outputs to the XR150FC/ XR55OFC system. Up to three Class B modules can be mounted within the FACP. Model 865 or 866 Class B NAC Modules may be combined with a power supply to provide additional 4 Amp NAC outputs. Use an 867 on the SLC Loop to further expand NAC circuits. FIRE DRILL AND ONE-MAN WALK TEST Users can test fire notification bells using the Fire Drill feature. A special code is also available for installers to test the system. The One-Man Walk test allows a single technician to check the panel response to fire, burglary, panic, and supervisory zones. BUILT-IN PROGRAMMER AND DIAGNOSTICS No programming device is required, enabling installers and service technicians to fully program the system and run diagnostics from any DMP LCD keypad. Check the electrical state of zones, find individual zone numbers, check the LX- Bus for missing, overlapping and/or extra zones, and much more, all from any DMP LCD keypad. FLASH UPDATABLE The XR150FC and XR55OFC panels accept software updates using Remote Link' software. This makes it easy to perform the flash update remotely any time new panel feature updates release. 1 I FIRE PANELS I OUTPUTS The XR150FC and XR550FC allow the use of two SPDT relay outputs and four open collector outputs, which may be activated by zone or system events, by schedule, through the User Menu, or when a card is presented. Output Groups allow multiple outputs to activate with a single event and/or can be assigned to a particular user profile. OUTPUT SCHEDULES Achieve maximum system flexibility with 100 programmable schedules that simplify planning and operations. Control any contact-activated device with schedules that automatically regulate relays and switched-ground outputs. STATUS LIST To provide maximum system flexibility, fire zones may be programmed to display at a specific keypad. In this manner, all fire zones can be monitored in one location, and other zones can be programmed to display and be monitored at different keypad locations. REMOTE LINK The Remote Link programming software takes advantage of the easy-to-use simplicity of Microsoft WindowsT°. The XR150FC and XR550FC panels include an interface connection for installers to use to connect a laptop computer. COMMERCIAL WIRELESS FIRE DEVICES The list of DMP wireless devices that have earned the UL Commercial Fire Listing include: 1103 Universal Transmitter: Two-input transmitter typically used in commercial burglary door or window applications. 1100R Wireless Repeater: Extends the communication range of DMP receivers, enabling physically larger, more reliable wireless security systems. 1100X Wireless Receiver: The 1100X Receiver supports up to 500 transmitters and satisfies all wireless applications. 1100XH High Power Wireless Receiver: Provides additional transmit and receive amplification for improved performance at greater distance or in harsh building environments. Commercial Smoke Detectors: The 1164 includes synchronized sounders, and a tamper switch. The 1164N5 is for applications with existing sounder/ notification devices. 1183 Wireless Heat Detector: The 1183 Series is a reliable, ceiling-mount heat sensor available in two versions. The 1183-135F responds if the temperature exceeds 135°. The 1183-135R adds a rate-of-rise feature that responds if the temperature increases by 15°F per minute or more. 1184 Carbon Monoxide Detector: The 1184 Carbon Monoxide Detector is the ideal choice for difficult-to- wire locations, applications where room aesthetics are critical, or where hazardous materials are present. The sensor provides an early alert of potentially harmful levels of carbon monoxide in residential or commercial installations. In addition, it also transmits trouble, tamper, and low-battery messages to the panel. 1 I I I " 0 Mini-Horn Motor Bell J ±1 Strobe Horn Strobe 11 Sync Module Sync Module 1183-135R 1103-W Wireless Rate of Rise Universal Transmitter Heat Detector 2L) 1164-W Commercial Listed Smoke Detector - with Sychronized Sounder 850S Manual Fire Alarm Pull Station 1100XH-W -- 1184-W Wireless Carbon Monoxide Detector 1103-W Universal Transmitter 1 630F I Remote Annxnicator I 711 715-8 or 715-16 Zone Expansion Module Zone Expansion Module I 1 FIRE PANELS Keypads 630F LCD Remote Fire Command Expansion Modules 710 Bus Splitter/Repeater 711 Single Zone Expansion 714 4-zone Class Expansion 714-8 8-zone Class-B Expansion 714-16 16-zone Class-B Expansion 115 4-zone 2-wire Smoke Expansion 715-8 8-zone 2-wire Smoke Expansion 715-16 16-zone 2-wire Smoke Expansion 716 Output Expansion, 4 Form C relays, 4 Open Collector Outputs 717 Graphic Annunciator: 20 Open Collector Outputs Cellular Communicators 263C COMA Cellular Communicator 263H HSPA+ Cellular Communicator 263HCAN HSPA Cellular Communicator Canada 263L1E-V LIE Communicator for Verizon 263L1E-A LIE AT&T (Coming Soon) Auxiliary Modules 860 Relay Output Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module 867 LX-Bus Notification Circuit Module 869 Style D Class A Initiating Circuit Module 893A Dual Phone Line Module Power Supplies 505-12/LX 5 Amps @12 VDC 505-12L 5 Amps @12 VDC 505-12A 5 Amps @12 VDC Pull Stations 850 Series Pull Stations Smoke/Heat Detectors 2W-BLX Conventional Smoke 2WT-BLX Conventional Smoke/Heat Accessories 270 Network Transient Suppressor 277 Commercial Fire Buzzer Module 300 Four-wire Harness 303 Silence/Reset Push Button 305 Plug-in Output Relay 306 Tamper Harness 301-S Screw-On Tamper Switch 3012 Clip-On Tamper Switch 335 Intrusion Siren 370 Lightning Suppressor 374 Surge Voltage Suppressor 381-2 18' Coax Extension 431 Output Harness 861 Power Distribution Module Central Station Receivers SCS-1R Network Enabled Receiver compatible with central station receivers that accept Standard CID, DD, or DMP Serial 3 messaging SCS-VR Virtual Receiver Software only solution that runs on a server for network IP and cellular communications DMP Wireless 1100X Receiver 1100XH High-Power Receiver hOUR Repeater 1103 Universal Transmitter, External Contact 1164 Wireless Smoke Detector with Synchronized Sounder 1164N5-W Wireless Smoke Detector with No Sounder 1183-135F Heat Detector 1183-135R Heat Detector 1184 Carbon Monoxide Detector Computer Software Remote Link Programming Software Dealer Admin System Specifications Primary Power (included): 16 VAC 56 VA transformer Secondary Power: 12 VDC Battery Models: 365, 366,368 or 369 Output Rating: Bell Up to .7 Amps at 12 VDC Smoke and Auxiliary Up to .5 Amps at 12 VDC For installations, total be/I, smoke, and auxiliary cannot exceed 1.2 Amps using a 56 VA transformer. Current Draw: 180mA Enclosure: Material Cold-rolled steel (Red) Ordering Information XR1SODFC-R XR1SO Fire Control Panel XR15ODNFC-R XR150 Fire Control Panel with Network XRSSODFC-R XRSSO Fire Control Panel XR55ODNFC-R XR550 Fire Control Panel with Network Listings and Approvals California State Fire Marshal ((SFM) New York FDNY Refer to the XR150FC/XR55OFC Compliance Guide (LT-1330) and specific compliance listings for installation and programming requirements necessary to meet a particular approval. FCC Part 68 FCC Part 15 Underwriters Laboratories (UL) Listed ANSI/UL 864 Fire Protective Signaling For additional information, go to DMP.com/Compliance. 800.641.4282 I DMP.cnm 2500 N. Partnership Bind, Springfield, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global components 2018 Digital Monitoring Products, Inc. I 11-1311 118143 263LTE-V CELLULAR COMMUNICATOR Installation Guide H 0 IJr IL 00 0 Figure 1: 263LTE-V The 263 LTE-V Cellular Communicator provides a fully-supervised alarm communication path over the Verizon LTE network. The 263LTE-V installs on the panel inside the enclosure and is powered by the panel so no additional enclosure, power supply, or battery back-up is needed. Compatibility Control panel firmware should be updated to the following versions when installing a 263LTE-V: XT30/XT50 Series panels with Version 172 or higher XR150/XR550 Series panels with Version 172 or higher INSTALL THE 263LTE-V Caution: Touch grounded metal to discharge 7 static before handling the panel. Open the panel enclosure and remove all power from the panel. If needed, remove the panel from the enclosure to allow easier placement of the 263LTE-V. Insert the included standoff into the XT30/XT50 or XR150/XR550 Series panel standoff hole. For XT30/XT50 Series panels, align the 263LTE-V SMA antenna connector with the antenna hole in the top of the panel enclosure and secure it on the 12-pin cell module connector. See Figure 2. For XR150/XR550 Series panels, secure the 263LTE-V on the 12-pin cell module connector. See Figure 3. Allign the 263L1E-V standoff hole with the standoff already placed in the panel and snap it into place. Standoff and 9 Back of the Standoff Hole SMA Connector I 263L rE-V 3 1 0 0 - Figure 2: 263LTE-V on an XT30/XT50 Panel Back of the Standoff and Standoff Hole Figure 3: 263LTE-V on an XR150/XR550 Panel What is Included 263LTE-V Cellular Communicator 383LTE antenna PCB standoff 381-2 18" coax cable with brass washers and nut 2 CONNECT THE ANTENNA I Be sure to only use the included 363L1E antenna when installing the 263L1E-V. XT30/XTSO Series Panel I Connect the included LTE antenna to the 263L1E-V SMA connector. See Figure 4. XR150/XR550 Series Panel 1. Attach one end of the included coax cable to the 263LTE-V SMA connector. Position one washer onto the other end of the coax cable and push the threaded end through the antenna knockout hole. Position the second washer onto the threaded end that extends through the antenna knockout hole and secure the nut. Attach the included LIE antenna to the coax cable SMA connector. See Figure 5. I Note: As an alternative, the coax cable can be connected directly to the 263L1E-V SMA connector when the coax cable enters the enclosure via conduit. ,1 • — p•i a - .a • • -. LTE Antenna SMA Connector 9 II II IIlI IcoI, Figure 4: XT30/XT5O Series Panel LTE Antenna Coax Cable Antenna SMA Connector Knockout Hole X Fe Figure 5: XR150/XR550 Series Panel 3 ACTIVATE THE 263LTE-V Cellular service is required before you can use the 263L1E-V for signal transmission. The 263LTE-V comes ready for activation with SecureComTM Wireless, LLC. Use Remote Link TM the Dealer AdminTM site (DMPDealerAdmin.com), the Tech APPTM, or call DMP Customer Service (1-866-266-2826) to activate the 263LTE-V Remote Link Activation Navigate to Remote Link and select a panel. Select Program in the top menu and select Communications from the drop- down menu. Select Cellular Network as the Communication Type and click Activate. Select SIM as the SIM Type. Enter the SIM number found on the 263LTE-V label and click Activate. Select a Rate Plan for the 263L1E-V and click Activate. I Dealer Admin Activation Navigate to the Dealer Admin site (DMPDealerAdmin.com). Click Customers in the right-side menu and select a customer. I Click Add System. Enter a System Name. Select XTLplus from the System Type drop-down menu. I Select either Cellular or EASYconnect + Cell Backup in the Connection Type field. Enter the SIM number found on the 263 LTE-V label and click Get Status. Enter the Account Number. I Select a Rate Plan for the 263L1E-V. Click Activate Cellular Device. I Tech APP Activation Navigate to the Tech APP. Tap Find a Customer then search for a customer. I Tap Add a System. Enter a System Name. Scan or enter the Serial #. I Select XTLplus from the System Type drop-down menu. Select either Cellular or EASYconnect + Cell Backup in the Connection Type field. Enter the Account Number. I Enter the SIM Number found on the 263LTE-V label then tap Get SIM Status. Select a Rate Plan for the 263LTE-V. I Tap Activate Cellular Device. A TEST THE 263LTE-V L_j The panel provides a diagnostic function to test the communication integrity and cellular I signal strength of the 263L1E-V to the nearest tower for the cellular carrier. To use the diagnostic function, reset the panel, enter 2313 (DIAG), and press CMD. I Communication Status This option tests the individual components of cellular or wireless network communication. I l. Select CELL STATUS from the Diagnostic menu. Possible test results are shown in Table 1. 2. Select YES to continue through the remaining component tests or select NO to I stop testing and return to CELL STATUS. Confirmed Faulty MODEM OPERATING NO MODEM FOUND I IDENTIFIED NO SIM CARD TOWER DETECTED NO TOWER REGISTERED NOT REGISTERED I CONNECT ERROR CONNECT SUCCESS NOT ACTIVATED I CELL PATH GOOD NO ACK RECEIVED Table 1: Cell Status Test Results I I 1 FCC INFORMATION This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and this device must accept any interference received, including interference that may cause undesired operation. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm (7.874 in.) from all persons. It must not be located or operated in conjunction with any other antenna or transmitter. Changes or modifications made by the user and not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to - part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver i connected. Consult the dealer or an experienced radio/TV technician for help. Industry Canada Information This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions: This device may not cause interference, and this device must accept any interference, including interference that may cause undesired operation of the device. Le present apparell est con forme aux CNR d'/ndustrie Canada app//cables aux apparel/s radio exempts de licence. L'exploitation est autorisëe aux deux conditions suivantes: l'apparei/ ne doit pas produire de brouillage, et l'utilisateur de l'appareil doit accepter tout brouillage radioé/ectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement. This system has been evaluated for RF Exposure per RSS-102 and is in compliance with the limits specified by Health Canada Safety Code 6. The system must be installed at a minimum separation distance from the antenna to a general bystander of 7.87 inches (20 cm) to maintain compliance with the General Population limits. L'exposition aux radiofrequences de ce système a étd éva/uee se/on la norme RSS-102 et est jugee con forme aux limites établies par /e Code de sécurité 6 de Sante Canada. Le système dolt étre insta/lé a une distance minima/e de 787 pouces (20 cm) séparant /'antenne dune personne prCsente en con formité avec les limites permises d'exposition du grand public. 263LTE-V CELLULAR COMMUNICATOR Specifications Primary Power 12VDC from panel Current Draw Standby 14mA Alarm 14mA (46mA peak transmitting) Accessories 381-2 18" Coax Cable 381-12 12' Coax Extension 381-25 25' Coax Extension 383LTE Dual Band Antenna (included) 386 Antenna Mounting Bracket Compatibility XT30/XT50 Series Version 172 or higher XR150/XR550 Series Version 172 or higher Certifications FCC Part 15: RI7ME910C1NV Industry Canada: 5131A-ME910C1NV Underwriters Laboratory (UL) Listed ANSI/UL 294 Access Control System Units ANSI/UL 636 Holdup Alarm Units and System Accessory ANSI/UL 1023 Household Burglar ANSI/UL 1076 Proprietary Burglar ANSI/UL 1610 Central Station Burglar ANSI/UL 1635 Digital Burglar ANSI/UL 985 Household Fire Warning ANSI/UL 864 Fire Protective Signaling 9th Edition ANSI/UL 365 Police Sta. Connected Burg Alarm Units & Systems ANSI/UL 609 Local Burg Alarm Units & Systems Specifications CellCom-LTE-V Primary Power Nominal 12VDC Current Draw 12VDC: Standby 55 mA Alarm 102 mA (Cellular Communication) CellComZ-LTE-V Primary Power Nominal 12VDC Current Draw 12VDC: Standby 107 mA Alarm 155 mA (Cellular Communication) CellComF-LTE-V Primary Power Nominal 12VDC or 24VDC Current Draw 12VDC: Standby 55 mA Alarm 102 mA (Cellular Communication) Current Draw at 24VDC: Standby 28 mA Alarm 49 mA (Cellular Communication) Dimensions and Color Housing Dimensions 5.5"W x 3.75"L x 1"H Housing Color CeltCom-LTE-V, CellComZ-LTE-V: White CellComF-LTE-V: Red Certifications Cellular FCC Part 15: MIVCNNO301 CellCom-LTE-V FCC Part 15 ID: CCKPCO163 (Telit modem) IC: 5251A-PC0163 (TeUt modem) Underwriters Laboratory (UL) Listed ANSI/UL 1610 Central Station Burglar (Cellular) ANSI/UL 1023 Household Burglar ANSI/UL 985 Household Fire Warning (CID Capture) Cel lComF-LTE-V Underwriters Laboratory (UL) Listed ANSI/UL 864 Commercial Fire Protective Signaling Systems (CID Capture) 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 DMP.COM 0 0 0 0 0 0 @DMPALARMS FEATURES Plug-and-play installation and activation of add-on communication modules Direct reporting to any DMP central station receiver with no relaying or intermediary retransmission of alarm signals Power from panel with low current draw for long standby battery life Fully supervised to ensure communication Can be equipped with local or remote antenna Check signal strength indication at the keypad Supports the DMP Virtual Keypad TI app XR550E provides privacy for your data with DMP encryption technology XR150FC/XR550FC with 263 Series communicators have FDNY approval for network or cell primary communication DMP Adaptive Technology1M switches communication paths while maintaining supervision if the current path becomes unavailable on the XR Series'TM panels Digital Cellular Communicators CELLULAR COMMUNICATORS PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and cost savings. For commercial fire applications, the 263H/263LTE can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Your cellular communicator can also be a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones, Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGYTM If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The check-in frequency and programming for a backup path adapt to the check-in programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit P data packets directly from the panel's processor over the HSPA+ or LTE wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP central station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom WireleSSTI from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, are ready to use the SecureCom service. VIRTUAL KEYPAD TM APP The DMP app provides users with the ability to access a number of system functions remotely via a cellular or Internet connection. As a dealer, the app provides the opportunity to brand it using your company logo. VIRTUALKEYPAD.COMTM Users can access their security system via Internet connection on a tablet or computer. Customers log into Virtual Keypad.com with their login and system user code. 263H/263LTE CELLULAR COMMUNICATORS For existing XT/XR Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263H/263LTE allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over their respective HSPA+ or LTE networks. It provides a fully supervised alarm communication path over the network. The 263H/263LTE is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply, or battery backup is needed.-Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263LTE does not include a SIM card and is activated with the ICCID number. All modules are ready for activation with SecureCom Wireless. 265H126511E CELLULAR COMMUNICATORS XTLpIus Series panel users can plug in the 265H or 265L1E cellular communicators to quickly and easily incorporate cellular communications. In the panel plastic, it requires no additional enclosures, power supplies, batteries, cabling, or conduit connections. The 265H contains HSPA+ technology, and the 265LTE contains LTE technology. Both do not include a SIM card and are activated with the ICCID number. All modules are ready for activation with SecureCom Wireless. Specifications Primary Power 12VDC from panel Current Draw (263H) Standby 24mA Alarm 28mA Current Draw (263L1E) Standby 14mA Alarm 14mA Current Draw (265H/265L1E) Standby 13mA Alarm 13mA Ordering Information 263H HSPA+ Cellular Communicator, XT/XR Series 263L1E-V LIE Cellular Communicator, XT/XR Series 265H HSPA+ Cellular Communicator, XlLplus 26511E-V LIE Cellular Communicator, )ClLplus Accessories 381-2 18" Coax Extension 381-12 12' Coax Extension 381-25 25' Coax Extension 383 Dual Band Antenna 383L1E Dual Band Antenna LIE 386 Wall Mount Antenna Bracket 387-2 2dB Attack Enclosure Antenna 387-4 4' SMA to N Extension Cable 387-8 8' SMA to N Extension Cable 387-25 SMA ION CABLE, 25F1, LMR195 387-50 SMA ION CABLE, 50F1, LMR195 388-1 3dB Fiberglass Antenna w/bracket 388-3 3dB MEG Antenna Certifications California State Fire Marshal (CSFM) New York City (FDNY COA #6167) Underwriters Laboratories (UL) Underwriters Laboratories Canada (ULC) For additional information, visit www.DMP.com and select Compliance. 800.641.4282 I DMP.com 2500 N. Partnership Bled, Springfield, MO 65803 Designed, Engineered 8 Manufactured in Springfield, MO using U.S. & global components © 2018 Digital Monitoring Products, Inc. I 11-1021 118213 DMP.COM 0 0 0 0 0 0 @DMPALARMS FEATURES Plug-and-play installation and activation of add-on communication modules Direct reporting to any DMP central station receiver with no relaying or intermediary retransmission of alarm signals Power from panel with low current draw for long standby battery life Fully supervised to ensure communication Can be equipped with local or remote antenna (heck signal strength indication at the keypad Supports the DMP Virtual Keypad TI app XR550E provides privacy for your data with DMP encryption technology XR150FC/XR550FC with 263 Series communicators have FDNY approval for network or cell primary communication DMP Adaptive Technologytm switches communication paths while maintaining supervision if the current path becomes unavailable on the XR Series1M panels Digital Cellular Communicators Specifications Primary Power 12VDC from panel Current Draw (263H) Standby 24mA Alarm 28mA Current Draw (263L1E) Standby 14mA Alarm 14mA Current Draw (265H/265L1E) Standby 13mA Alarm 13mA Ordering Information 263H HSPA+ Cellular Communicator, XT/XR Series 263L1E-V LIE Cellular Communicator, XT/XR Series 265H HSPA Cellular Communicator, XTLplus 26511E-V LIE Cellular Communicator, XlLplus Accessories 381-2 18" Coax Extension 381-12 12' Coax Extension 381-25 25' Coax Extension 383 Dual Band Antenna 383L1E Dual Band Antenna LIE 386 Wall Mount Antenna Bracket 381-2 2dB Attack Enclosure Antenna 387-4 4' SMA to N Extension Cable 387-8 8' SMA to N Extension Cable 387-25 SMA ION CABLE, 25F1, LMR195 387-50 SMA ION CABLE, 50F1, 1MR195 388-1 3dB Fiberglass Antenna w/bracket 388-3 3dB MEG Antenna Certifications California State Fire Marshal ((SFM) New York City (FDNY COA #6167) Underwriters Laboratories (UL) Underwriters Laboratories Canada (ULC) For additional information, visit www.DMP.com and select Compliance. 800.641.4282 I DMP.com 2500 N. Partnership Blvd, Springfield, MO 65803 Designed, Engineered & Manufactured in Springfield, MO using U.S. & global components ® 2018 Digital Monitoring Products, Inc. I LT-1027 118213 I -7 I CELLULAR COMMUNICATORS I PRIMARY OR BACKUP PATH Configure your DMP digital cellular communicator as the primary path, providing installation flexibility and cost savings. For commercial fire applications, the 263H/263LTE can be used as a stand- alone communicator without the need for a backup. Cellular is the right choice for locations not easily reached by phone or land lines, or where there are concerns that physical communication links might be tampered with. Your cellular communicator can also be a backup communication path, providing the security of a communication link that continues to function, even when land lines are cut or compromised. FULLY SUPERVISED You're kept fully informed of system status. The unit sends full reporting messages including Zones, Areas, and Users, with all names and details included. Full supervision ensures that the cellular communication path is intact and functional. ADAPTIVE TECHNOLOGrM If the primary communication path is compromised or becomes unavailable, Adaptive Technology almost instantly switches to a designated backup path. Where multiple backups are available, communications can be programmed to switch to another path as necessary. The check-in frequency and programming for a backup path adapt to the check-in programming of the primary path. When the primary path becomes available, normal communications are restored. Adaptive Technology provides additional confidence in the integrity of your system, while protecting you from unexpected cellular service charges. DIRECT DATA TRANSMISSION The digital cellular communicators transmit IP data packets directly from the panel's processor over the HSPA+ or LTE wireless data network. All of the messages that are capable of being sent by the control panel are received directly by the DMP central station receiver. There are no intermediary servers or network operation centers, and no retransmission or reinterpretation of the information. Direct reporting means faster response, with no concerns about signals not being properly relayed or intermediate communication links failing. CELLULAR SERVICE FLEXIBILITY With SecureCom Wireless from DMP, you have a one-stop resource for both hardware and cellular service. DMP digital cellular communicators, whether selected as original equipment in a new panel or added to an existing panel via an expansion card, are ready to use the SecureCom service. VIRTUAL KEYPAD TM APP The DMP app provides users with the ability to access a number of system functions remotely via a cellular or Internet connection. As a dealer, the app provides the opportunity to brand it using your company logo. VIRTUALKEYPAD.COM°° Users can access their security system via Internet connection on a tablet or computer. Customers log into VirtualKeypad.com with their login and system user code. 263H/263LTE CELLULAR COMMUNICATORS For existing XT/XR Series panels not originally configured with cellular communications, the 263 Series expansion cards let you add cellular capabilities. The 263H/263LTE allows alarm messages to be communicated to an SCS-1R or SCS-VR Receiver over their respective HSPA+ or LIE networks. It provides a fully supervised alarm communication path over the network. The 263H/263LTE is installed in the panel enclosure and powered by the panel so no additional enclosure, power supply, or battery backup is needed. Plug-and-play installation makes upgrading your panel quick and easy. The 263H includes a SIM card. The 263L1E does not include a SIM card and is activated with the ICCID number. All modules are ready for activation with SecureCom Wireless. 265H/265LTE CELLULAR COMMUNICATORS XTLplus Series panel users can plug in the 265H or 265LTE cellular communicators to quickly and easily incorporate cellular communications. In the panel plastic, it requires no additional enclosures, power supplies, batteries, cabling, or conduit connections. The 265H contains HSPA+ technology, and the 265LTE contains LIE technology. Both do not include a SIM card and are activated with the ICCID number. All modules are ready for activation with SecureCom Wireless. Ii I I I F I 0 5Lrc L!' SECURITY -- - - I SIGNAUNG Simple Expansion Solutions Expand your DMP Command Processor panel options with a wide array of expansion modules. Add supervised Class B burglary zones. Connect non-powered burglary or fire type devices for intrusion, gtassbreak, and motion detection. Add 12 VDC zones for addressable 2-wire smoke detectors with 715 moduels. -7- I* Ij1 1I)IT1 I1[trn LI!JlII* III I.jiIiIjJi Td 141 I)]III ZONE EXPANSION MODULE FEATURES Provides Class B zones for burglary and fire Compatible with DMP Command Processor Panels that allow zone expansion Suitable for mounting near protection devices Connect devices using 4-wire bus Easily mount attractive cases on wall or 3-gang box Compatible with all panel zone types Easy connection to 4-wire keypad or LX-Bus Proven design ensures stability and performance Data LED on zone expander indicates good panel communication Durable and attractive plastic or metal housing Low current draw Can be powered from panel or auxiliary power supply rE rrnncrn FE S I USE ON THE DMP LX-BUSTM The modules can be used on the LX-Bus of DMP Command Processorw Panels. The modules connect to the 4-wire bus and use only one zone address. To assign an additional zone expander use the next available zone address. CONNECT TO KEYPAD BUS You can also use the modules as an addressed device on the keypad data bus of DMP Command Processor panels. Simply set the module to an available keypad address and connect the wiring to the appropriate screw terminals. SIMPLE ADDRESSING Address the 711, 714, 714-8, 714-16, 715, 715-8, 715-16, and 725 modules by setting two on-board rotary switches with a small screwdriver. The 712-8 uses slide dip switches. EASY INSTALLATION Zone Expansion Modules are mounted in a decorative plastic housing suitable for installing outside the panel enclosure, such as on walls or single gang boxes. After all wiring connections are made, the cover snaps on to form tight-fitting protection against incidental contact or tampering. 714-8, 714-16, 715-8, and 715-16 Zone Expanders are housed in a rugged, 20-gauge, cold-rolled steel enclosure. You may also mount the 708, 710, 710F, and 725 modules inside a DMP enclosure using the 3-hole configuration and the provided standoffs. The 712-8 only mounts using the 3-hole configuration and provided standoffs. 708 BUS EXTENDER MODULES The 708 Bus Extender Modules allow you to increase the length of wire used to run an LX-Bus or keypad bus by a maximum of 4,000 feet, while providing immunity to noise on the wires. The 708 Bus Extenders are received from the factory as a pair of modules that connect between the panel and LX-Bus or keypad bus devices. Use the 708 Modules for applications that include running wire over long distances, through noisy environments, or where the bus is bundled with other wires, such as telephone company wire. The 708 Extender can be used on all DMP panels. 708 FEATURES Extends Keypad Bus or LX-Bus by 4000 feet with one pair of modules Connects to an auxiliary power supply for added power Uses existing wire: No need to run additional wire Allows twisted pair and/or shielded wire between the 708 modules 710!710F BUS SPLITTER! REPEATER MODULES The 710 and 7101 Bus Splitter/Repeater Modules allow you to expand the typical LX-Bus or Keypad bus installation both in the number of devices and the length of the wire used. Each 710/710F Module provides three bus connections each up to 2,500 feet. When using multiple modules, the total distance of all circuits can be an incredible 15,000 feet! -- 710 As a splitter, the 710 provides superior mechanical wire connecting capability for up to three additional 12 VDC LX-Bus or keypad bus circuits. This makes the 710 module an excellent junction box when terminating multiple LX-Bus/keypad bus runs at one location. As a repeater, the 710 module can be installed at the end of an LX-Bus or keypad bus circuit to allow an additional circuit to be added, thus increasing the total wire length. 710F As well as providing all of the functions of the 710 listed above, the 710F also allows you to use the 725 Zone Expander to expand the number of 24 VDC zones. The 7101 Bus Splitter/Repeater allows the connection of a 24 VDC power supply to the 725 to power smoke detectors and isolate the 24 Volt source from the panel. Therefore, the 7101 must be used when using the 725 Zone Expander. 712-8 ZONE EXPANSION MODULE Expand your system at an affordable price! You can connect non-powered burglary devices to DMP Command Processor panels using the 712-8 Module. The 712-8 Module is compatible with many intrusion contacts, glassbreak detectors, motion detectors, and intrusion detectors. 712-8 FEATURES Eight grounded, addressable burglary zones Set jumper for LX-Bus or Keypad bus operation Compatible with all DMP Command Processor panels Expand systems by daisy chaining a second 712-8 Easily address using dip switches Snaps into panel enclosure using 3-hole pattern Separate zone 1K End-of-Line resistors included ZONE PROGRAMMING I Program the zone on the modules with any of the panel's available zone types for use in burglary applications including I Arming type zones when used with keyswitches. The expansion zones are programmable I for annunciation on DMP keypads connected to the panel. Each zone can also be individually programmed to report alarms, troubles, and restorals to remote DMP SCS-1R Receivers. 1 7141715 ZONE EXPANDERS The 714 contains four Class B burglary zones and is suitable for use with burglary and fire devices that are normally opened or normally closed. Individual zones are supervised with 1k Ohm EOL resistors and can be programmed with any burglary or fire zone type. The 715 contains four Class B powered zones and is suitable for use with 12 VDC, 2-wire smoke detectors and non-powered fire or burglary devices. Individual zones on the 715 are supervised with a 3.3k Ohm EOL resistor and can be programmed with any burglary or fire zone type. OPTIONAL ACCESSORIES The standard wiring harness can be replaced with the optional 7181 Plug-in Screw Terminal. The enclosure can also accommodate the 7191 Terminal Boards for the 714 or the 7201 Terminal Boards for the 715, which pass through the wiring of the panel's LX-Bus. 1K EOL resistors are included with the 719T and 3.3K resistors are included with the 7201. 7141715 FEATURES Four protection zones on each module Comes with 12-conductor wire harness Optional 12-position screw terminal 714-8,714-16,715-8, AND 715-16 DESCRIPTION The expanders are housed in a Model 340 locking metal enclosure suitable for mounting in a remote location. Each expander provides screw terminal strips for zone inputs and data bus connections, a two position jumper to designate connection to the keypad bus or the LX-Bus, and an LED to indicate communication with the panel. Separate zone End-of-Line resistors are included with each expander. 714-81714-16 EXPANDERS The 714-8 Expander contains 8 Class B zones. The 714-16 Expander contains 16 Class B zones. Both are suitable for use with normally open or normally closed burglary and fire devices. Individual zones are supervised with a 1k Ohm EOL resistor and can be programmed as any zone type. 715-8/715-16 EXPANDERS The 715-8 Expander contains 8 Class B powered zones. The 715-16 Expander contains 16 Class B powered zones. Both are suitable for use with 12 VDC 2-wire devices, such as smoke detectors or with non-powered fire or burglary devices. Individual zones are supervised with a 3.3k Ohm EOL resistor and can be programmed as any zone type. 714-8,714-16,71 S-8, AND 715-16 FEATURES 8 or 16 protection zones per expander Durable metal enclosure housing with lock and key Individual screw terminals accommodate 14 to 22 gauge wire for easy connection Suitable for mounting in a remote location 725 24 VDC EXPANSION MODULE The 725 provides four 24 VDC powered zones that enable you to connect 2-wire smoke detectors to the XRSOO Series, XR2500F, XR200, and XR200-485 Command Processor Panels. As a result, the 725 provides you the flexibility to retrofit a 24 Volt system without the need to run more wire or change to 12 Volt smoke detectors. 725 FEATURES Provides four 24 VDC zones Sensor reset performed through panel relay or 716 Output Expander Powered from 24 VDC power supply Supervised operation 24 Volt surge protection from 710F Provides ability to use 24 VDC 2-wire smoke detectors Easily mounted in 3-hole pattern ill DESCRIPTION The 711 Zone Expansion Module connects to the panel's 4-wire keypad bus or LX-Bus and are set to an address that determines the reporting zone number. The 711 provides one Class B zone for the connection of detection devices. 711 FEATURES Single-zone expander Rugged screw terminals accommodate 14 to 22 AWG Board fits in Radionics POPIT housing Easy rotary switch addressing 1 ' ZONE EXPANSION MODULE COMPARISON CHART Refer to the chart below for a comparison of the features for each DMP Zone Expansion Module. Module Address Number of Zones 3-HolePlastic Case Operating Voltage Compatible Panels 708 N/A N/A Yes Yes 12 VDC All DMP I 710 N/A N/A Yes Yes 12 VDC 710F N/A N/A Yes Yes 12 VDC 712-8 Dip Switch 8 Yes No 12 VDC XT Series, XR100/XR500 Series, XR2500F 12 VDC 711 Rotary 1 No Yes 12 VDC 714 Rotary 4 Class B No Yes 12 VDC 714-8 Rotary 8 Class B No Metal Enclosure 12 VDC 714-16 Rotary 16 Class B No Metal Enclosure 12 VDC 715 Rotary 4 Class B No Yes 12 VDC 715-8 Rotary 8 Class B No Metal Enclosure 12 VDC 715-16 Rotary 16 Class B No Metal Enclosure 725 Rotary 4 24 VDC Class B No Yes 24 VDC XR500 Series, XR2500F NODULE SPECIFICATIONS 7141715 SPECIFICATIONS 708 SPECIFICATIONS (NONE UL) Operating Voltage 8.8 to 15.0 VDC Operating Voltage 8.8 to 15.0 VDC Operating Current Operating Current 20mA Per Pair 714 Average 7mA + 1.6mA per zone Dimensions 4.5" X 2.75" X 1.75" Alarm 7mA + 2mA per zone Maximum Distance 4,000 feet between the two 715 Average 7mA + 4mA per zone + 0.1 per 2-wire smoke 708 Modules Alarm 7mA + 58mA per shorted zone + 0.1 per 71 0/71 OF SPECIFICATIONS 2-wire smoke + 30mA per smoke in alarm Operating Voltage 8.8 to 15.0 VDC Dimensions 4.5" X 2.75" X 1.75" Operating Current 7I48, 714-16, 71 58, AND 71 5-16 SPECIFICATIONS 710 30mA Operating Voltage 8.8 to 15.0 VDC 710F 40mA Operating Current Dimensions 4.5" X 2.75" X 1.75" 714-8/16 Distance 2,500 feet (one module), Average 20mA + 1.6mA per zone 15,000 feet maximum Alarm 20mA + 2mA per zone 711 SPECIFICATIONS 715-8/16 Operating Voltage 8.8 to 15.0 VDC Average 20mA + 4mA per zone + 0.1 per 2-wire smoke Operating Current Alarm 20mA + 58mA per shorted zone + 0.1 per Average 11 mA + 1 .6mA per active zone 2-wire smoke + 30mA per smoke in alarm Alarm 11 m + 2mA per zone in alarm Enclosure 20-Gauge cold-rolled steel Zone Voltage 5 VDC (1.6mA across EOL) Dimensions 12.5" W x 11.5" H x 3.5" D Dimensions 4.5" X 2.75" X 1.75" 714-8/-16 Color Gray 715-8/-16 Color Red 712-8 SPECIFICATIONS LISTINGS AND APPROVALS Operating Voltage 8.8 to 15.0 VDC Refer to the appropriate panel programming and installation guide Current Draw 17mA + 1 .6mA per active zone for specific compliance listings for installation and programming 17mA + 2mA per zone in alarm requirements necessary to meet a particular approval. Dimensions 4.5" H x 2.5" W Underwriters Laboratories (UL) Listed 725 SPECIFICATIONS California State Fire Marshall (CSFM) Operating Voltage 24 VDC Nominal New York City MEA accepted (711, 714, 715 only) Average Current 8mA + 4mA per active zone Alarm Current 8mA + 4mA per active zone + 30mA per smoke in alarm For additional information, access www.dmp.com and select + 47mA per shorted device Compliance. EOL Resistor Model 316 6.8k EOL F __ L 1 2500 North Partnership Boulevard MP Dig .IMnflo.ngPrdt. [ I Springfield, Missouri 65803-8877 I I I I Li I I 1 El I [1 System Sensor's /3' series smoke detectors reares significant advancement in conventional detecti The /3 family is founded on three principles: instal, Photoelectric Smoke Detectors SYSTEM $ SENSOR® ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Installation ease. The il line redefines installation ease with its plug-in design.This allows an installer to pre-wire the bases included with the heads, The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors, To complete the installation, P heads plug in to the base with a simple Stop-Drop 'N Lock' action. Intelligence. j3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the j3 line to minimize nuisance alarms.Two-wire P detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the i3 protocol.This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent per-foot-obscuration. Instant inspection. The j3 series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on two-wire i3 detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Agency Listings & <~> 0 MEA MSFM LISTED APPROVED approved approved 0911 3011446 7272-1209.210 29001-E 2093 (_j. Smoke Detector Specifications Architectural/Engineering Specifications Smoke detector shall be a System Sensor P Series model number listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms, The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 8.5V - Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F—i 20°F (0°C-49°C); 2WT-B and 4WT-B: 32°F-1 00°F (0°C-37.8°C) Operating Humidity Range 01095% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.50/o/ft. nominal Input Terminals 14-22 AWG Mounting LED Modes LED Mode Green LED 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power Up Sequence for LED Indication Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No Wiring Alarm Current 2-wire 130 mA max. limited by control panel 2\NT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ IN 23mA @ 24V Accessories 2W-MDD2 2-wire loop test / maintenance module RI Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter "STEM Syster Secr. \ , IWI 3825 Ohio Avenue. St. Charles, IL 60174 Product specifications subject to dinaingewithout notIce.Visitsysternsensorcomfor SEIIISOR Phone: 800-SENSOR2. Fax: 630-377-6495 current product information, inducling the latest version of this dam she~t A CUSTOM DOCUMENT ENCLOSURE Modified Mier BW-1 06R for Bay Alarm 12"W x 12"H x 4"D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom SYSTIM REOID CLiEt Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling or emailing Mier Products,lnc. 800-473-0213 1 info@mierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY '& FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:0135 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Digital Monitoring Products2500 N. Partnership Blvd, Springfield, MO 65803 Contact: Brad Tucker (417) 831-9362 Fax (417) 831-1325 Email: btucker@dmp.com DESIGN: Models XR150, XR350 and XR550 combination fire and burglary alarm control units. Local, remote station, proprietary and central station services. Models may have a combination of the following suffixes: D (dialer), N (network), E (encryption) or FC (fire control). Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR150, XR350, XR550: Main Board 341, 349, 350, 350A, 352P 352X: Enclosures 352S: Battery Enclosure 630F: Supervised LCD Keypad 7070, 7070A, 7073, 7073A, 7170, 7170A, 7173, 7173A, 7570, 7570A, 7573, 7573A: LCD Keypads 325: Transformer Bracket 322, 323, 324, 324P, 327: Transformers 711, 714, 714-8, 714-16, 715, 715-8, 715-16: Zone Expanders Output Expander Annunciator Module 860 Relay Module 893A: Dual Phone Line Module 734, 734N: Wiegand Interface 710: Bus Splitter 270: Network Transient Suppression Module 277: Trouble Sounder 9060, 9063: Wireless Keypads 263C, 2631-1: Cellular Communicator *(May be used as the standalone primary communicator) *263LTE: Cellular Communicator (NOT for use with XR350) *(May be used as the standalone primary communicator) 865, 866, 867: Indicating Module 869: Initiating Module 303: Reset/Silence Switch 1100X, 1100XH: RF Wireless Receiver hOUR: Wireless Repeater 1103: Wireless Transmitter *Rev 03-07-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division I I I I Li Li I Listing No. 7165-1157:0135 Page 2 of 2 1135: Wireless Siren RATING: 120 VAC, 0.5 A, 60 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating and UL label. APPROVAL: Listed as combination fire and burglary alarm control units for use with separately listed electrically compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. NOTE: 1. The Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Burglary and other non-fire functions were not examined. *Rev 03-07-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 1 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 1 LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: VIadimir.KireyevhoneywelI.com DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-13 photoelectric type smoke detectors. Models 2W-13 and 2WT-B are 2-wire and model 4W-B and 4WT-13 are 4-wire detectors. Models 2WT-B and 4WT-13 employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division