Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; ; FPC2017-0304; Permit4 of PERMIT REPORT ity Carlsbad Print Date: 12/16/2021 Permit No: FPC2017-0304 Job Address: 2525 EL CAMINO REAL, # 100, CARLSBAD, CA 92008-1204 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: Track #: Applied: 10/23/2017 Valuation: $0.00 Lot #: Issued: 11/02/2017 Occupancy Group: Project #: Finaled Close Out: 02/02/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: MALL MANAGMENT OFFICE -SPRINKLER TI 7-100 (20) Applicant: FPContractor: VFS FIRE & SECURITY SERVICES VFS FIRE AND SECURITY SERVICES SALVADOR JASSO 501 W SOUTHERN AVE 501 W SOUTHERN AVE ORANGE, CA 92865-3217 ORANGE, CA 92865-3217 (714) 778-6070 (714) 919-8351 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ffC-?-,c)i4-D3o4- FIRE & SECURITY SERVICES VFS FIRE AND SECURITY 501 W. SOUTHERN AVE. ORANGE, CA 92865 714 778 6070 Job Name : THE SHOPPES AT CARLSBAD Building FP-2 Location 2525 EL CAMINO REAL CARLSBAD CA 92008 System : SYS-10 AREA 1 Contract : 173212 Data File SYSTEM 10 T.I.WXF Computer Programs by Hydratec Inc. Revision: 50.52.1 VFS FIRE AND SECURITY Page 1 THE SHOPPES AT CARLSBAD Date 05-10-2017 HYDRAULIC CALCULATIONS for Project name: MALL MANAGENENT OFFICE Location: 2525 EL CAMINO REAL CARLSBAD CA 92008 Drawing no: FP-2 Date: 10/23/17 Design Remote area number: SYS-1 0 AREA 1 Remote area location: 1 Occupancy classification: L.H / OH-2 Density: .10 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 225 - SqFt Type of sprinklers calculated: GL 5601 K=5.6 Q/R 155 No. of sprinklers calculated: 18 In-rack demand: 0 - GPM Hose streams: 250 - GPM Total water required (including hose streams): 0 - GPM @ 0 - Psi Type of system: WET Volume of dry or preaction system: -Gal Water supply information Date: 04-05-2017 Location: MARRON RD. WEST OF PLAZA DRIVE (WESTFIELD PLAZA) Source: HYDRANT NUMBER; H60994 Name of contractor: VFS Fire & Security Services Address: 501 W. Southern Ave. / Orange, CA 92865 / Phone number: (714)778-6090 Name of designer: SAL JASSO Authority having jurisdiction: Notes: (Include peaking information or gridded systems here.) -10% FROM PRESSURES -10% WAS DEDUCTED FROM EXISTING STATIC AND RESIDUAL PRESSURES Computer Programs by Hydratec Inc. Revision: 50.52.1 Water Supply Curve C VFS FIRE AND SECURITY Page 2 THE SHOPPES AT CARLSBAD Date 05-10-2017 City Water Supply: Demand: Cl - Static Pressure : 82.8 Dl - Elevation : -1.480 C2 - Residual Pressure: 37.8 D2 - System Flow .439.862 C2 - Residual Flow : 6050 D2 - System Pressure : 42.296 Hose ( Demand) : 250 - D3 - System Demand : 689.862 Safety Margin : 39.694 150 140 130 p120 R0 E10° 90 : C1 Sou U 70 R 60 E 50- 40 ::r!:: 20 10 7591500 2250 3000 3750 4500 5250 6000 6750 FLOW (N - 1.85 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram VFS FIRE AND SECURITY Page 3 THE SHOPPES AT CARLSBAD Date 05-10-2017 - 26 HDI<- DRPI 0 H02<- DRP2 0 HD3<- DRP3 24.8 100<-. 1 1 I 24.8 22. 101 <- 2 24.5 1024- 3 22 103<- 3 1- I 46.5 104<- 3A 23.6 105<- 5 22.5 1064- 6 I I 22.5 107<- 7 1- 45.8 23. 108<-- 8 24.3 109<- 10 23.5 111<- 12 t I 23.5 23. 112<- 13 I 46.8 24. 212<- 130 1 I 71.7 24. 213<- 131 26.5 113<- 15 26.6 114<- 17 28.2 115<- 19 28.4 116<- 21 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Diagram VFS FIRE AND SECURITY Page 4 THE SHOPPES AT CARLSBAD Date 05-10-2017 24.8 1 <-2 <-4 47.7 46.5 3 <-3A<-4 69.3 23.6 5 (-9 22.5 69.5 6 <-7 <-8 <-9 45.8 24.3 10 <- 14 23.5 71.7 12 <-13 <-130<-- 131<- 14 46.8 95.9 26.5 15<- 16 1- 356.8 26. 17 <- 18 1- I 383.3 28. 19 <-20 1' 411.5 28. 21 <- 22 117 330.3 356.8 411.5 439.9 439.9 439.9 439.9 4 <-9 <-14 <_14A<- 16 <-18 <-20 <-22 <-23 <-24 <--BRS4- TRS<- 8R52- UG <- UGI<- CON 210.1 330.3 383.3 439.9 439.9 439.9 439.9 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 VFS FIRE AND SECURITY Page 5 THE SHOPPES AT CARLSBAD Date 05-10-2017 SUPPLY ANAL YSIS Node at Source Static Pressure Residual Pressure Flow Available Pressure Total Demand Required Pressure CON 82.8 37.8 6050.0 81.99 689.86 42.296 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes HD1 9.0 5.6 21.56 26.0 HD2 9.0 0.0 HD3 9.0 0.0 100 9.0 5.6 19.56 24.77 101 9.0 5.6 16.78 22.94 102 9.0 5.6 19.11 24.48 103 9.0 5.6 15.47 22.03 104 9.0 5.6 16.6 22.81 105 9.0 5.6 17.73 23.58 106 9.0 5.6 16.14 22.5 107 9.0 5.6 17.25 23.26 108 9.0 5.6 17.99 23.75 109 9.0 5.6 18.78 24.27 111 9.0 5.6 17.66 23.53 112 9.0 5.6 17.27 23.27 212 9.0 5.6 19.79 24.91 213 9.0 5.6 18.69 24.21 113 9.0 5.6 22.31 26.45 114 9.0 5.6 22.49 26.56 115 9.0 5.6 25.3 28.16 116 9.0 5.6 25.68 28.38 1 9.0 22.07 2 9.0 23.2 3 9.0 21.11 3A 9.0 22.56 5 9.0 24.41 6 9.0 22.12 7 9.0 23.76 8 9.0 25.35 10 9.0 26.64 12 9.0 24.77 13 9.0 25.13 130 9.0 25.57 131 9.0 25.62 15 9.0 32.3 17 9.0 33.25 19 9.0 33.86 21 9.0 36.08 4 9.0 24.49 9 9.0 26.17 14 9.0 26:94 14A 9.0 31.46 Computer Programs by Hydratec Inc. Revision: 50.52.1 Flow Summary - NFPA 2007 VFS FIRE AND SECURITY Page 6 THE SHOPPES AT CARLSBAD Date 05-10-2017 NODE ANALYSIS (cont.) Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes 16 9.0 32.75 18 9.0 33.65 20 9.0 34.53 22 9.0 36.19 23 9.0 39.92 24 12.417 41.4 BRS1 12.417 41.5 TRS 25.417 36.0 BRS2 17.417 39.7 UG 12.417 41.91 UG1 12.417 42.28 CON 12.417 42.3 250.0 Computer Programs by Hydratec Inc. Revision: 50.52.1 EOD VFS FIRE AND SECURITY Page 7 THE SHOPPES AT CARLSBAD Date 05-10-2017 Node 1 Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf HD1 9 5.60 26.00 1 2E 4.0 2.000 120 21.556 to T 5.0 9.000 0.0 DRP1 9 26.0 1.049 0.0 11.000 0.2115 2.326 Vel = 9.65 0.0 DRP1 26.00 23.882 K Factor= 5.32 HD2 9 .0 0.0 1 0.0 4.000 0.0 to 0.0 0.0 .0 DRP2 9 0.0 1.049 0.0 4.000 0 0.0 Vel = 0 0.0 DRP2 0.0 0.0 K Factor = 0 HD3 9 .0 0.0 1 0.0 10.000 0.0 to 0.0 0.0 .0 DRP3 9 0.0 1.049 0.0 10.000 0 0.0 VeI= 0 0.0 - DRP3 0.0 0.0 K Factor 0 100 9 5.60 24.77 1 E 2.0 6.000 120 19.559 to T 5.0 7.000 0.0 1 9 24.77 1.049 0.0 13.000 0.1933 2.513 Vel = 9.20 0.0 1 24.77 22.072 K Factor = 5.27 101 9 5.60 22.94 1 4E 8.0 25.250 120 16.783 to T 5.0 13.000 0.0 2 9 22.94 1.049 0.0 38.250 0.1677 6.416 Vel = 8.52 0.0 2 22.94 23.199 K Factor = 4.76 102 9 5.60 24.48 1 0.0 10.583 120 19.109 to 0.0 0.0 0.0 3 9 24.48 1.049 0.0 10.583 0.1891 2.001 Vel = 9.09 0.0 3 24.48 21.110 K Factor = 5.33 103 9 5.60 22.03 1 4E 8.0 23.250 120 15.471 to T 5.0 13.000 0.0. 3 9 22.03 1.049 0.0 36.250 0.1556 5.639 Vel = 8.18 0.0 3 22.03 21.110 KFactor= 4.79 104 9 5.60 22.81 1 4E 8.0 22.917 120 16.595 to T 5.0 13.000 0.0 3A 9 22.81 1.049 0.0 35.917 0.1660 5.962 Vel = 8.47 0.0 3A 22.81 22.557 K Factor = 4.80 105 9 5.60 23.58 1 4E 8.0 24.875 120 17.726 to T 5.0 13.000 0.0 5 9 . 23.58 1.049 0.0 37.875 0.1764 6.683 Vel = 8.75 0.0 5 23.58 24.409 K Factor = 4.77 106 9 5.60 22.50 1 4E 8.0 23.958 120 16.143 to T 5.0 13.000 0.0 6 9 225 1.049 0.0 36.958 0.1618 5.981 Vel = 8.35 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 8 THE SHOPPES AT CARLSBAD Date 05-10-2017 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ****** Notes Node2 EIev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 0.0 6 22.50 22.124 KFactor= 4.78 107 9 5.60 23.26 1 4E 8.0 24.792 120 17.252 to T 5.0 13.000 0.0 7 9 23.26 1.049 0.0 37.792 0.1721 6.503 Vel = 8.63 0.0 7 23.26 23.755 K Factor = 4.77 108 9 5.60 23.75 1 4E 8.0 28.125 120 17.994 to T 5.0 13.000 0.0 8 9 23.75 1.049 0.0 41.125 0.1789 7.357 Vel = 8.82 0.0 8 23.75 25.351 K Factor= 4.72 109 9 5.60 24.27 1 4E 8.0 29.208 120 18.780 to T 5.0 13.000 0.0 10 9 24.27 1.049 0.0 42.208 0.1861 7.856 Vel = 9.01 0.0 10 24.27 26.636 K Factor= 4.70 111 9 5.60 23.53 1 4E 8.0 27.458 120 17.658 to T 5.0 13.000 0.0 12 9 23.53 1.049 0.0 40.458 0.1758 7.113 .Vel = 8.73 0.0 12 23.53 24.771 K Factor = 4.73 112 9 5.60 23.27 1 5E 10.0 30.667 120 17.269 to T 5.0 15.000 0.0 13 9 23.27 1.049 0.0 45.667 0.1722 7.865 Vel = 8.64 0.0 13 23.27 25.134 K Factor = 4.64 212 9 5.60 24.91 1 E 2.0 22.583 120 19.794 to T 5.0 7.000 0.0 130 9 24.91 1.049 0.0 29.583 0.1954 5.780 Vel = 9.25 0.0 130 24.91 25.574 K Factor = 4.93 213 9 5.60 24.21 1 3E 6.0 26.458 120 18.685 to T 5.0 11.000 0.0 131 9 24.21 1.049 0.0 37.458 0.1852 6.939 Vel = 8.99 0.0 131 24.21 25.624 KFactor= 4.78 113 9 5.60 26.45 1 5E 10.0 30.792 120 22.309 to T 5.0 15.000 0.0 15 9 26.45 1.049 0.0 45.792 0.2182 9.994 Vel = 9.82 0.0 15 26.45 32.303 KFactort 4.65 114 9 5.60 26.56 1 6E 12.0 31.917 120 22.491 to T 5.0 17.000 0.0 17 9 26.56 1.049 0.0 48.917 0.2199 10.757 Vel = 9.86 0.0 17 26.56 33.248 K Factor= 4.61 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 9 THE SHOPPES AT CARLSBAD Date 05-10-2017 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt, Act Eqv. Ln. Total Pf/Ft Pf 115 9 5.60 28.16 1 2E 4.0 25.917 120 25.296 to T 5.0 9.000 0.0 19 9 28.16 1.049 0.0 34.917 0.2452 8.560 Vel = 10.45 0.0 19 28.16 33.856 K Factor = 4.84 116 9 5.60 28.38 1 2E 4.0 27.833 120 25.679 to 2T 10.0 14.000 0.0 21 9 28.38 1.049 0.0 41.833 0.2486 10.399 Vel = 10.54. 0.0 21 28.38 36.078 K Factor = 4.72 1 9 24.77 1 0.0 5.833 120 22.072 to 0.0 0.0 0.0 2 9 24.77 1.049 0.0 5.833 0.1932 1.127 Vel = 9.20 2 9 22.94 1.5 T 8.0 8.000 120 23.199 to 0.0 8.000 0.0 4 9 47.71 1.61 0.0 16.000 0.0807 1.291 VeI= 7.52 0.0 4 47.71 24.490 K Factor= 9.64 3 9 46.51 1.25 0.0 8.875 120 21.110 to 0.0 0.0 0.0 3A 9 46.51 1.38 . 0.0 8.875 0.1630 1.447 Vel = 9.98 3A 9 . 22.81 1.5 T 8.0 4.000 120 22.557 to 0.0 8.000 0.0 4 9 69.32 1.61 0.0 12.000 0.1611 1.933 VeI= 10.92 0.0 4 69.32 24.490 K Factor = 14.01 5 9 23.58 1 T 5.0 5.000 120 .24.409 to . 0.0 5.000 0.0 9 9 23.58 .1.049 0.0 10.000 0.1765 1.765 Vel = 8.75 0.0 9 23.58 26.174 K Factor= 4.61 6 9 22.50 1 0.0 10.083 120 22.124 to 0.0 0.0 0.0 7 9 22.5 1.049' 0.0 10.083 0.1618 1.631 Vel = 8.35 7 9 23.26 1.25 0.0 10.083 120 23.755 to 0.0 0.0 0.0 8 9 45.76 1.38 0.0 10.083 0.1583 1.596 Vel = 9.82 8 9 23.75 1.5 0.0 5.083 120 25.351 to 0.0 0.0 0.0 9 9 69.51 1.61 0.0 5.083 0.1619 0.823 Vel = 10.95 0.0 9 69.51 26.174 K Factor = 13.59 10 9 24.27 1.5. T 8.0 5.000 120 26.636 to 0.0 8.000 0.0 14 9 24.27 1.61 0.0 13.000 0.0232 0.301 Vel = 3.82 0.0 14 24.27 26.937 K Factor = 4.68 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 10 THE SHOPPES AT CARLSBAD Date 05-10-2017 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqv. Ln. Total Pf/Ft Pf 12 9 23.53 1.5 E 4.0 12.625 120 24.771 to 0.0 4.000 0.0 13 9 23.53 1.61 0.0 16.625 0.0218 0.363 Vet = 3.71 13 9 23.27 2 T 10.0 9.083 120 25.134 to 0.0 10.000 0.0 130 9 46.8 2.067 0.0 19.083 0.0231 0.440 Vet = 4.47 130 9 24.92 2 0.0 1.000 120 25.574 to 0.0 0.0 0.0 131 9 71.72 2.067 0.0 1.000 0.0500 0.050 Vet = 6.86 131 9 24.20 2 T 10.0 5.083 120 25.624 to 0.0 10.000 0.0 14 9 95.92 2.067 0.0 15.083 0.0871 1.313 Vet = 9.17 0.0 14 95.92 26.937 K Factor= 18.48 15 9 26.45 1.25 T 6.0 1.833 120 32.303 to 0.0 . 6.000 0.0 16 9 26.45 1.38 0.0 7.833 0.0574 0.450 Vet = 5.67 0.0 16 26.45 32.753 K Factor = 4.62 17 9 26.56 1.25 T 6.0 1.000 120 33.248 to 0.0 6000 0.0 18 9 26.56 1.38 0.0 7.000 0.0579 0.405 Vet = 5.70 0.0 18 2656 33.653 K Factor = 4.58 19 9 28.16 1.25 T 6.0 4.417 120 33.856 to 0.0 6.000 0.0 20 9 28.16 1.38 0.0 10.417 0.0644 0.671 Vel= 6.04 0.0 20 - 28.16 34.527 K Factor= 4.79 21 9 28.38 2 T 10.0 2.750 120 36.078 to 0.0 10.000 0.0 22 9 28.38 2.067 0.0 12.750 0.0091 0.116 Vet = 2.71 0.0 22 28.38 36.194 K Factor= 4.72 4 9 117.03 2.5 4E 32.948 10.750 120 24.490 to 0.0 32.948 0.0 9 . 9 117.03 2.635 0.0 43.698 0.0385 1.684 Vet = 6.89 9 9 93.09 2.5 0.0 6.708 120 26.174 to 0.0 0.0 0.0 14 9 210.12 2.635 0.0 6.708 0.1137 0.763 Vet = 12.36 14 9 120.19 2.5 E 8.237 9.000 120 26.937 to 0.0 8.237 0.0 14A 9 330.31 2.635 0.0 17.237 0.2627 4.528 Vet = 19.43 14A 9 0.0 3 E 9.408 4.417 120 31.465 to 0.0 9.408 0.0 16 9 330.31 3.26 0.0 . 13.825 0.0932 1.288 Vet = 12.70 16 9 26.45 3 0.0 8.375 120 32.753 to 0.0 0.0 0.0 18 9 356.76 3.26 0.0 8.375 0.1075 0.900 Vel = 13.71 Computer Programs by Hydratec Inc. Revision: 50.52.1 Final Calculations - Hazen-Williams VFS FIRE AND SECURITY Page 11 THE SHOPPES AT CARLSBAD Date 05-10-2017 Nodel Elevl K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 EIev2 Fact Qt Act Eqv. Ln. Total PfIFt Pf 18 9 26.56 3 0.0 7.125 120 33.653 to 0.0 0.0 0.0 20 9 383.32 3.26 0.0 7.125 0.1227 0.874 Vel 14.73 20 9 28.16 3 0.0 11.917 120 34.527 to 0.0 0.0 0.0 22 9 411.48 3.26 0.0 11.917 0.1399 1.667 Vel 15.82 22 9 28.38 3 T 20.159 3.375 120 36.194 to 0.0 20.159 0.0 23 9 439.86 3.26 0.0 23.534 0.1583 3.725 Vel 16.91 23 9 0.0 4 T 26.334 42.583 120 39.919 to 0.0 26.334 -1.480 24 12.417 439.86 4.26 0.0 68.917 0.0430 2.965 Vel = 9.90 24 12.417 0.0 8 2E 42.282 14.583 120 41.404 to 0.0 42.282 0.0 BRS1 12.417 439.86 8.249 0.0 56.865 0.0017 0.097 Vel = 2.64 BRS1 12.417 0.0 8 E 21.141 13.000 120 41.501 to T 41.108 62.249 -5.630 TRS 25.417 439.86 8.249 0.0 75.249 0.0017 0.130 Vel = 2.64 TRS 25.417 0.0 8 B 14.094 8.000 120 36.001 to S . 52.853 129.196 3.465 BRS2 17.417 439.86 8.249 E 21.141 137.196 0.0017 0.236 Vel = 2.64 T 41.108 BRS2 17.417 0.0 8 E 21.141 5.000 120 39.702 to 0.0 21.141 2.166 UG 12.417 439.86 8.249 0.0 26.141 0.0017 0.044 Vel = 2.64 UG 12.417 0.0 8 4E 84.564 131.000 120 41.912 to 0.0 84.564 0.0 UG1 12.417 439.86 8.249 0.0 215.564 0.0017 0.371 Vel = 2.64 UG1 12.417 0.0 8 0.0 10.000 140 42.283 to 0.0 0.0 0.0 CON 12.417 439.86 8.27 0.0 10.000 0.0013 0.013 Vel = 2.63 250.00 Qa = 250.00 CON 689.86 42.296 KFactor = 106.07 Computer Programs by Hydratec Inc. Revision: 50.52.1 Fittings Used Summary VFS FIRE AND SECURITY Page 12 THE SHOPPES AT CARLSBAD Date 05-10-2017 Fitting Legend Abbrev. Name /z % 1 11/4 11/z 2 2'/ 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Unit Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.52.1 QUICK RESPONSE UPRIGHT CONVENTIONAL / QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL SIDEWALL I \ A. FIRE. SPRINKLER CORPORATION QUICK RESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT e PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule ex- ceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depend- ing upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. *Temperature Ratings - 1350F (57T), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) *Water Working Pressure Rating -175 psi (12 Bars) oFactory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass *Bulb seat - copper • Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODIN AVAILABLE SPRINKLER N.F.P.A. MAXIMUM CLASSIFICATION TEMPERATURES BULB COLOR CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C168°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4077AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX989-846-9231 MAY 2011 A-20 BULLETIN GL5615, REV. #7 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT. PENDENT. VERTICAL SIDEWALL HORIZONTAL SIDEWALL * CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4 (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2 NPT 2 1/4 (5.7 cm) Bright Chrome Satin Chrome 2 5.6 (80 metric) 1/2 NPT 2 1/4" (5.7 cm) White Polyester 7.8 (111 metric) 1/2 NPT 2 1/4" (5.7cm) Black Polyester 2.3 8.1 (116 metric) 3/4 NPT 2 7/16" (6.2 cm) Lead Coated 2,3 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F cULus F. M. LPC CE NYC - DOB MEA MODEL FACTOR 57°C 68°C 79°C 93°C 141°C 101-92-E GL2815 2.8 X X X X X X - - - X GL4215 4.2 X X X X X X --- - -- X UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8° X X X X X X -- - - X GL8118 8.1 X X X X X X X X X X GL2801 2.8 X X X X X X -- - .- X GL4201 4.2 X X X X X X -- - - X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8* X X X X X X X - - X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X x - -- -- SIDEWALLt GL8133 8.1 X X X X X X - - -- GL2826 2.8 X X X X X X - - X HORIZONTAL GL4226 4.2 X X X X X X - . --- -- X SIDEWALL § GL5626 5.6 X X X X X X X - -- X GL8127 8.1 X X X X X X - - - -- CONVENTIONAL GL5624 5.6 X X X X X (OLD STYLE) GL8125 8.1 X X X X X - - X X -- ORDERING INFORMATION SPECIFY Quantity • Model Number • Style Orifice • Thread Sizes • Temperature Finishes desired Quantity - Wrenches - P/N 325390 (1/2°); P/N 312366 (L.O.) FIRE SPRINKLER CORPORATION "1/2" NPT t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4° TO 6". GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufac- tured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com MAY 2011 PRINTED U.S.A. BULLETIN GL5615, REV. #7 VicFlexTM Sprinkler Fittings JtauI c Series AH1, AH2 and AH4 Braided Flexible Hose Assemblies 10.85 Approvals/Listings: c®uS LPCB LISTED G412024 1041-01 See Victaulic Publication 10.01 for more details. Product Description: VicFlex sprinkler fittings provide sprinkler installation on suspended ceiling grids, wood or metal stud/joist or hat furring channel hard-lid ceilings utilizing a flexible, stainless steel hose and steel bracket assembly. Refer to the Installation Manual for all applicable ASTM ceiling material and installation standards. System Components Hoses: Series AH1 Braided Hose Series AH2 Braided Hose Series AH4 Braided Hose Assembly lengths: 31, 36, 48, 60, 72/790, 914, 1220, 1525, 1830mm. Note: length includes branch-line nipple and 5.757140mm straight reducer. Sprinkler Reducers: ½ and %715 and 20 mm sprinkler connections and 5.757140mm, 9/230mm, 137330mm straight lengths and short, long 900 elbows. Note: The short 900 elbow is typically used with concealed sprinklers while the long 900 elbow is typically used in the installation of recessed pendent sprinklers. Branch Connections: 1/25mm NPT or BSPT branch line nipples for attaching to rigid pipe. 3/a720mm NPT or BSPT available for VdS. Brackets: Style AB1 for suspended and hard-lid ceilings, allows installation before ceiling tiles in place Style AB2 for hard-lid ceilings, allows for vertical sprinkler adjustment Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style AB7 for suspended ceilings and hard-lid ceilings Style AB7 Adjustable for suspended and hard-lid ceilings Style AB8 for hard-lid ceilings (regionally available) Style A139 for hard-lid ceilings with hat furring channel grid systems Style AB1O for Armstrong® TechZone" ceilings victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic company. All rights reserved. 1 ictauIic victau!ic.corn I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Technical Specifications: Material Specifications: Maximum Working Temperature: 225°F/107°C Maximum Working Pressure: 200 psi/1375 kPa (FM Approval) 175 psi/1206 kPa (cULus Listed -Series AH1 and AH2 only) 1600 kPa/232 psi (VdS/LPCB Approved) Connections: To branch line (inlet) via 1/25.4 mm NPT or BSPT male thread OR To branch line (inlet) via 3/4'720 mm BSPT male thread (VdS only) To sprinkler head (outlet) via ½' or 3/4'715 mm or 20 mm NPT or BSPT female thread Minimum Bend Radius: 7/178 mm (FM Approval) 2/51 mm (cULus Listed - Series AH2 only) 3/76.2 mm (cULus Listed - Series AH1 only) 3/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors: FM (½'YlSmm reducer) K5.6/8,1 (SI.) (34'720mm reducer) K14.0/20,2 (S.I.) cULus (1/2'715mm reducer) K8.0/11,5 (SI.) (1/4'720mm reducer) K14.0/20,2 (SI.) VdS/LPCB (1/2715mm reducer) K5.6/8,1 (SI.) (3/4'720mm reducer) K8.0/11,5 (SI.) Series AH1 Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc Plated Reducers (½ or 3/4'): Carbon Steel, Zinc-Plated Series AH2 Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc Plated Reducers (½ or /4"): Carbon Steel, Zinc-Plated Series AH4 Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: EPDM per ASTM 02000 Isolation Ring: N/A Nut and Nipple: Carbon Steel, Zinc-Plated Reducers (½ or /4"): Carbon Steel, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated 10.85 5839 Rev W updated 01/2015 © 2015 Victaulic company. All rights reserved. victa.orn 2 Ata_ulic~ vic.taulic corn I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 cus FRICTION LOSS DATA: ( LISTED -Series AH2 Braided Hose with Straight 5.75 Reducers -Style AB1 and AB10 Brackets Series AH2 Hose Maximum Length of Equivalent Length Number of Stainless Steel of 1/33.7mm 900 Bends at 2/51mm Flexible Hose Outlet Size Sch. 40 Pipe (C=120) Bend Radius inches inches/type feet/meters ht 31 9 4 3/4"/Strai9ht ..................................... ..........ff/4.-. .................................................................................... 17/5.2 4 /Strai9T 21/64 1/4 /Straight 23/7.0 1/2" _/StraiL 32/9.8 8 48 37/11.3 ............................................10 60 .............................................. ~"/Strai9ht ..................................................... .10 ...I.!.9.bt_.................. 1A._ 72 ight ~/Stra 12 - 53/16.2 12 Series AH2 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 20/51mm center line bend radius Length of Stainless Steel Flexible Outlet 1 2 3 4 5 6 . 7 8 9 10 11 12 Hose Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches ½" 8.5/2.6 11.0/3.4 13.0/4.0 1 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A 31 3% 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A N.A N4 N.A l 135/41 160/49 180/55 190/58 210/64 NA NA NA NA NA NA NA ~" ½" 14.0/4.3 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 21.0/6.4 N.A N.A N.A 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A N.A N.A N.A N.A 48 . ~" 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 t 30.0/9.1 37.0/11.3 N.A N.A I N.A N.A ½" 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 L37.0/11.3142.0/12.8144.0/13.4 46.0/14.01 N.A N.A 60 3/4' 23.0/7.0 24.0/7.3 1 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6'42.0/12.8 44.0/13.4 46.0/140 N.A N.A 1V" 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 142.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 72 32.0!9.8 32.5/9.9 35.0/10.7 ......./10.8 40.i2. 40.5/12... 2PL5.2 5..0/15.5 52.... Note: Values for use with 5.75 straight reducers How to use this Design Guide: 1 For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of.bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. 2 It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. U 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic Company. All rights reserved. victaulic.corn 3 \/ltaulic victau!ic.corn I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 ccvs FRICTION LOSS DATA: -Series AM Braided Hose with Straight 5.75" Reducers LISTED -Style AB1 and AB10 Brackets Series AH1 Hose Maximum Length of Equivalent Length Number of Stainless Steel of 1/33.7mm 900 Bends at 3/76.2mm Flexible Hose I Outlet Size Sch. 40 Pipe (C=120) Bend Radius inches inches/type feet/meters ½/Straight .. 31 . - - -.- - 3/4"/Strigh! ..................................................s........ L22____ 4.L___ - 36 ... ............................ 1/2"/Straight 78/23.8 4 48 .5?/15.8 .55/16..,8 80/24.4 _______Straih 88/26.8 4 60 90/27.4 ........................................ 4 .... ............ VS __. 1 5 ........ .......- . ................ 72 3/4 . .1L34._ Series AH1 AH1 Braided Hose Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 3/75mm center line bend radius Length of I Stainless. Steel Flexible Outlet 1 2 3 4 5 Hose Size Bend Bends Bends Bends, Bends inches inches 1/2'. 32 42 52 N.A N.A 31 3/4 33 44 55 N.A N.A ½ 33 43 53 63 N.A 36 3/4 36 46 56 66 N.A ½ 46 57 68 78 N.A 48 ~W 51 60 71 1 80 N.A ½ 56 67 77 88 N.A 60 3/4 58 69 80 90 N.A ½' 69 79 ' 91 102 112 72 3/4 73 84 95 106 118 Note: Values for use with 5.75 straight reducers. How to use this Design Guide: 1 For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. 2 It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 10.85 5839 Rev W Updated 0112015 © 2015 Victaulic Company. All rights reserved. victa.u!ic.co.m 4 ________ victau..c.corn I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 FRICTION LOSS DATA: -Series AH1, AH2 and AH4 Braided Hose -Various brackets specific to hose - --- --- ------ Series AH1 Hose - ------ Series AH2 Hose Series AH4 Hose For use with Style AB1, AB2, For use with Style AB1, AB2, AB4, AB7, A87 Adj., AB8, AB9 AB4, A137, AB7 Adj., AB8, AB9 For use with Style AB1, AB7, AB8, and AB10 VicFlex Brackets and AB10 VicFlex Brackets and AB9 VicFlex Brackets Length of Maximum Maximum Maximum Stainless Equivalent i Number of Equivalent Number Equivalent Number Steel Length of 1 900 Bends at Length of of 900 Bends at I Length of I of 90° Bends at Flexible Sprinkler I Outlet 1/33.7mm 1 77178mm Bend 1/33.7mm 7/178mm 1/33.7mm i 7/178mm Hose* K-Factor Size Sch. 40 Pipe Radius Sch. 40 Pipe Bend Radius I Sch. 40 Pipe Bend Radius inches mperial/S.l.1 inches/type feet/meters feet/meters feet/meters ½fai 53.8/16.4 23.5/7.1 31 5.6/8.1 2 2 2 21.7/6.6 ½°/90 Elbow 53.8/16.4 23/7.0 36 56/81 • X '.1t....- 2 27.8/8.5 — 0 1 2 --- 2 ½°/90 Elbow 63.1/19.2 27.7/8.4 1 29.8/9.0 1/2"/Straight 87.9/26.8 38.2/11.6 j 27.5/8.3 48 56/81 29.2/8.9 ½0/9O Elbow 85.8/26.1 37.4/11.4 112.2/34.1 42.4/12.9 _19____4 4 60 56/8 1 37.2/11.3 ½°/90 Elbow 108.4/33.0 43/13.1 ..Yi7.!a..9ht .6 -- 46.6/.4.2 5./ 72 • 56/81 ½°/90 Elbow 131.1/39.9 48.5/14.7 4 47.5/14.5 31 8.0/11.5 2 23/4"/90* Elbow t—%-------- 2 Stri 55.6/16.9 25.0/7.6 21.7/6.6 36 80/11 5 /4°/90 Elbow 57.5/17.5 2 2 2 22.4/6.8 24.6/7.5 3.5/.°• 48 80/11 5 °/4"/90 Elbow 81.7/24.9 3 34.7/10.6 3 3 22.2/6.7 60 8.0/11.5 i4VStrai9h..10.1/33.5 _.1?: 4 4 /4°/90 Elbow 105.9/32.2 1 40.1/122 28.9/8.8 72 8 0/11 5 1/4"/Straight 137.3/41.8 43.5/13.2 38.8/11.8 45.2/13.7 /°/9O° Elbow 130.2/39.7 39.4/12.0 31 11.2/16.1 3 /4"/Straight 2 2 2 4"/90 Elbow .......45.5/13.8 47.1/14.3 18/5.5 19.9/6.1 ..Y19b ----- ........- 2 ------' 2 36 112/161 1/4"/90 Elbow 57.5/17.5 2 22.1/6.7 24.2/7.4 48 11.2/16 82.7/25.2 32.9/10.0 28.5/8.7 32.1/9.8 /4"/90 Elbow 82.8/25.2 60 112/161 1/33.2 36..811.2 rn.. 5 1 4 L 4 /4"/90 Elbow 108.1/32.9 37.1/11.3 30.3/9.2 72 112/161 9t ..._P3/4 L12.3 4 4 /4°/90 Elbow 133.4/40.6 41.9/12.7 38.6/11.7 31 140/202 3/4 /Strai3L 44.3/13.5 2 14.9/4.5 2 16.3/5.0 2 15.5/4.72 ~°/90 Elbow 46.4/14.1 19.9/6.1 I .iSi/S!ait!t 55.5/16.9 19.4/5.9 21.8/6.7 36 140/202 '/4°/9O 2 2 2 24.2/7.4 Elbow .LI3._ 56.7/17.3 19.6/5.9 48 14.0/20.2 Elbow 3 L... 3 %'/90 Elbow 82.1/25.0 29.5/8.9 29.9/9.1 .60 .0/2a2 3 ___ J/StraiL 137.9/42.0 37.5/11.4 41.5/12.6 72 14.0/20.2 I..........................................................................38./....................................................... 1/4"/9O...bow .............32.8/40.4 FM Notes: Series AH1, AH2 and AH4 have been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 5 X.Ac_ta_ulic~ VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 FRICTION LOSS DATA: L1 FRICTION LOSS DATA: -Series AH2 Braided Hose -Style AB1 Bracket Vt.) -Series AH1, AH2 and AH4 Braided Hose -Style AB1, AB2, AB4, AB7, AB7 Adj., AB8, AB9, and AB10 Brackets Series AH1 Hose Series AH2 Hose Equivalent Length of Equivalent Length of steel pipe according to steel pipe according to steel EN 10255 ON 20 EN 10255 ON 25 (26,9 x 2,65) and (33,7 x 3,25) and Length of Stainless Outlet relating to a flow relating to a flow Steel Flexible Hose Size velocity of 5 m/s velocity of 5 m/s mm/inches mm/inches type meters/feet meters/feet 790/31 4.0/12.9 5.5/18.0 20mmI/4/Straight 9156 6.4/21.0 .6A/21.O 1220/48 6.1/20.0 8.5/27.9 .. .. t!Y.bt 1525/60 15mm / '/z'/ Straigt!t 7.6/25.0 10.7/35.1 1830/72 .................m/3/4 _1 TLtra.hL /Strai9ht .......................................................................................................................................................................................................................... 9.2/30.0 12.8/42.0 VdS Ceiling Manufacturers List ABI, AB2, AB7, AB1O AB419 AB8 1. AMF 2. Armstrong No specific approval 1. Hilti 3. Chicago Metallic 2. Knauf 4. Dipling 3. Lafarge 5. Durlum 4. Lindner 6. Geipel 5. Rigips 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn Series AH4 Hose Equivalent Length of pipe according to EN 10255 ON 25 Maximum Number (33,7 x 3,25) and of 900 Bends at relating to a flow 3/76.2mm Bend velocity of 5 m/s Radius meters/feet 5.5/18.0 3 8.5/27.9 3 . ....................................................................... 10.7/35.1 4 12.8/42.0 4 Series AH2 Hose Equivalent Length of steel pipe Length of . according to Maximum Stainless EN 10255 ON 20 Number of Steel (26,9 x 2,65) and 900 Bends at Flexible Outlet relating to a flow 3/76.2mm Hose Size velocity of 5 m/s Bend Radius mm/inches mm/inches/type meters/feet 790/31 Straight 12.65/41.5 2 15m1,L5t.. 915/36 2Omm/~ 14.8/48.6 3 15rnnjStaiht 1220/48 1Tmmiia /Straight 15/49.2 3 1525/60 ...in1L.11~LS~t!9b. 15.3/50.2 3 /4/ Straight _ 1830/72 r m..111/X21.!..tr19 rpm.......L.Sti9ht 17.5/57.4 .................................................................................. 3 Series AH2 Hose Equivalent Length of steel pipe Length of 1. according to EN Maximum Stainless 10255 ON 25 Number of Steel (33,7 x 3,25) and 900 Bends at Flexible Outlet relating to a flow 3/76.2mm Hose Size velocity of 5 m/s Bend Radius mm/inches i mm/inches/type meters/feet 11 5m / ½°/ 900 Elbow 790/31 14.4/47.2 2 i20mm/3/4 /90 Elbow 915/36 pmm/1°/9p.Elbow Elbow 14.3/46.9 3 [15wnI.. . 1220/48 ....L._1 9 I20mm/4 /90 Elbow 15.3/50.2 3 1/19/ 1525/60. l20mm/1/4 /90 Elbow 16.0/52.5 3 1830/72 15mm / 11/90° Elbow 17.1/56.1 3 20 mm/1/4"/ 90 Elbow 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic company. All rights reserved. vita.ulic.com 6 ICtaUhc victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Product Details - Series AH1 Braided Hose A 1IEI1I1F ________________ 4 B Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31/790 25.25 31/790 36/915 31.25 36/915 48/1220 42.25 48/1220 60/1525 54.25 60/1525 72/1830 66.25 72/1830 Series AH2 Braided Hose Series AH4 Braided Hose Item Description 1 Flexible Hose 2 Isolation Ring (Series AH1 and AH2 only) Gasket 4 Nut 5 Branch Line Nipple 6 Braid 7 Collar/Weld Fitting - 8_ Sleeve (AH2 Only) Standard 5.75/140 mm straight reducer Optional 9.0/229 mm straight reducer 13.0/330 mm straight reducer 2.62/ 2.62/ —1 66.5 mm - 66.5 mm 12m 160.0 mm Short 900 elbow reducer Long 900 elbow reducer Note: The Short 900 elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of rebessed pendent sprinklers. 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic company. All rights reserved. victaulic.com 7 J'taUtIC vctaulic.corn VicFlex Sprinkler Fittings I AH1 AH2 AH4 Publication 10.85 VicFlex Brackets Style AB1 Suspended Ceilings Hard-Lid Ceilings (FM Only) Item i Description ) 24"/610mm or 48"/1219mm Square Bar* 2 Patented 1-Bee2 Center Bracket 3 End Bracket *Both sizes FM/VdS/LPCB approved, cuLus listed Style AB2 Hard-Lid Ceilings Item Description or 4871219mm Square Bar 2 Patent-Pendin9 adjustable center bracket 3 I End Bracket *Both sizes FM/VdS approved. Note: tf /4mm hex key required for adjustment Style AB4 Hard-Lid Ceilings with Hat furring channel grid system Item I Description 1 I 2476iOmmor48712i9rnrnSquareBar* 2 - - Patent-Pending adjustableCenterbracket 3 End Bracket for Nat Furring Channel *Both sizes FM/VdS approved. Note: ttf / 4mm hex key required for adjustment 10.85 5839 Rev W updated 01/2015 © 2015 Victaulic company. All rights reserved. viçta.U..c.c.om 8 &ct9UIiC v.ctau!ic.com .VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 VcFIex Brackets Style AB7 Suspended Ceilings Hard-Lid Ceilings Item i Description 1)2Y61Omrnor48712i9mmSquareBar* 2 1 Patented 1-Bee Center Bracket 1 3 1 End Bracket 'Both sizes FM/VdS approved. Style AB7 Adjustable Suspended Ceilings Hard-Lid Ceilings Item Description 2 Patented I -Bee" Center Bracket End Bracket (adjustable) 'Both sizes FM and VDS approved. Style AB8 Hard-Lid Ceilings Item I Description L11700mm or 1400mm Square Bar 2 Patented 1-Bee2 Center Bracket 1 3 End Bracket (adjustable) 'Both sizes FM/VdS approved Style AB9 Hard-Lid ceilings with Hat furring channel grid, system Description 1 j 24/610mm or 48/1219mm Square Bark 2 I Patented 1-Bee Center Bracket i End Bracket for Hat Furrina Channel 'Both sizes FM/VdS approved Style AB1O Suspended ceilings Armstrong® TechZone" ----..-.---.--..- Item Description 1 671 52m Square Bar 2 1 Patented 1-Bee2 Center Bracket I 3 End Bracket *FM/VdS approved, cULus listed. 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic company. All rights reserved. victa.u!içc.orn 9 Ac—tauljc Hose Clearance Chart Dimension inches/mm Minimum Bend 2/50 1 3/80 1 4/100 5/125 6/150 7/175 Radius T" Minimum A 10.75/273 11.75/298.512.75/324 13.75/349 14.75/375 1 15.75/400 am 17/4. Typicel ne M. victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Braided Hose Assembly Suspended Ceiling Grid with Recessed Sprinkler - Clearances above ceiling tile at various center-line bend radii on Center V707 'AI19 MM MAX. RECESS V2707 34/l9mm Max. Recess Suspended Ceiling Grid with 90°Elbow (Long) Sloe AB I Hose Clearance Chart i see ien 113m. 8/200 1/016 rnm E Ice rile Note: Style A131 and Series AH2 figures shown. TypI 'grid (. gZJjJ Variations of ceiling grids, sprinkler heads, brackets, ica and hoses are permitted but may result in clearance Seenore 247610 nnnn ceiling face differences from the figures above. °r 4871219 mm an Center V2707 3/4 /l9mm Max. Recess 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic company. All rights reserved. viçta.U..c.corn 10 __________ victaulic.com I VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Series AQB Braided Hose Assembly Suspended Ceiling Grid with Hat Furring Channel Hose Clearance Chart Dimension inches/mm Minimum Bend Radius °R° 2/50 3/80 4/100 5/125 6/150 7/175 Minimum "A" 10.3/262 11.3/287 j 12.3/313 13.3/338 14.3/363.5! 15.3/389 \R See Chart See Chart Note V2708 1/2712.7mm Max. Recess Suspended Ceiling Grid with 9000bow (Short) Hose Clearance Chart inches! I Dimension j mm A Mi 8/200 Note: Style AB9 and Series AH2 figures shown. Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. iii 'e' 0A V3802 1/2712.7mm Max. Recess 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic Company. All rights reserved. victa.u!ic.c.om 11 Ar--taul.c victau!ic.comI VicFlex Sprinkler Fittings I AH1 I AH2 I AH4 I Publication 10.85 Flexible Hose In-Plane Bend Characteristics ONE BEND TWO BENDS 2X Minimum bend radius 2X Minimum Minimum bend radius I'bend radius Minimum I bend radius 90. L\L OR OR Minirr bend nimum rd radius Minimum I bend radius I. Minimum bend radius Minimum bend radius Note: For out-of-plane (three-dimensional) bends care must be taken to avoid imparting torsional stress on the hose Model Number Correlation AquaFlexa Designation VicFlex -- Designation Series AH4 Outlet Series AQB Series AFB Hose Size Hose i Hose Assembly inches - Assembly Assembly ½ AQB31HLD AFB31HLD - AH431 3/4 AQB31TLD I AFB31TLD ½ AQB36HLD AFB36HLD Al-14-36 1/4 AQB36TLD AFB36TLD ½ AQB48HLD AFB48HLD AH4 -48 ~ AQB48TLD AFB48TLD ½ AQB60HLD AFB60HLD - A1-14 60 ~ AQB60TLD AFB60TLD ½ AQB72HLD AFB72HLD - AH4 72 3/4 AQB72TLD AFB72TLD -. .- -. - .- ........-. A WRNINi It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal inhiry and/or property damage. Installation . Note Reference should always be made to l-VICF1_EX-AB1-AB2-AB10, l-vlcFLEx-A84-AB9, This product shall be manufactured by Victaulic or to Victaulic specifications. All products l-v1cFLtx-A87, or l-VlcFLEX-A88 for the product you are installing. Handbooks are lobe installed in accordance with current Victaulic installation/assembly instructions. included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to change product specifications, designs and standard data, and are available in PDF format on our website at www.victaulic.com. equipment without entice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and VicFlex are registered trademarks of Victaulic company. 10.85 5839 Rev W Updated 01/2015 © 2015 Victaulic Company. All rights reserved. victaulic.com 12 X'A_Cta_U1iCr