HomeMy WebLinkAbout2510 EL CAMINO REAL; ; FPC2020-0173; Permit47 ity of PERMIT REPORT Carlsbad Print Date: 11/10/2020 Permit No: FPC2020-0173 Job Address: 2510 EL CAMINO REAL, CARLSBAD, CA 92008-1273 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 1670305000 Track #: Applied: 10/05/2020 Valuation: $145,343.75 Lot #: Issued: 10/29/2020 Occupancy Group: Project #: Finaled Close Out: 11/10/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: CVS -SPRINKLER TI (11 HEADS) Applicant: FPContractor: O SUPPRESSION INC CJ SUPPRESSION INC ROBIN MOYER 205 LEWIS CT 205 LEWIS CT CORONA, CA 92882-1812 CORONA, CA 92882-1812 (951) 735-5560 (951) 735-5560 FEE AMOUNT FIRE'NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FM Approved and Fully Listed Sprinkler Pipe SCHEDULE 10 SPECIFICATIONS Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, NOMINAL NOMINAL C-UL and FM Listed. NPS NOM 00 NOM ID WALL WEIGHT UL PIECES In. mm in. mm In. mm Ibs./ft. kg/rn CRR Lift Approvals and Specifications Both products meet or exceed 1'/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 the following standards: 11/2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 ASTM A135, Type E, Grade A (Schedule 10) 2 2.375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 ASTM A795, Type E, Grade A (Schedule 40) 2½ 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 NFPA13 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 Manufacturing Protocols Schdule 10 and Schedule 40 are subjected 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 to the toughest possible testing protocols to 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 ensure the highest quality and long-lasting performance. 6 6.625 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 Finishes and Coatings - All Wheatland black steel fire sprinkler pipe Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. up to 6' receives a proprietary mill coating to Threaded Schedule 40 steel pipe Is used as the benchmark (value of 7.0). ensure a clean, corrosion-resistant surface that I coatings. outperforms and outlasts standard lacquer This coating allows the pipe to be SCHEDULE 40 SPECIFICATIONS easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in NOMINAL NOMINAL black, or with hot-dip galvanizing, to meet NPS NOM OD NOM ID WALL WEIGHT UL PIECES FM/UL requirements for dry systems that meet In. mm In. mm In. mm Ibs./ft. kg/rn CRR Lift the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is 1 1.315 33.4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 also UL Listed. 1¼ 1.660 42.2 1.380 35.1 .140 3,56 2.27 3.39 1.00 51 Product Marking 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 Each length of Wheatland fire sprinkler pipe is continuously stenciled to show 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 . 30 the manufacturer, type of pipe, grade, size Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category ViZY. and length. Barcoding is acceptable as a The CRR Is ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). supplementary identification method. @ C @ APPROVED PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: 0 BLACK 0 HOT-DIP GALVANIZED C 2-020 -otS Wheatland Tube ./MC STEEL GROUP tqCJ30 Contacts Worldwide www.tyco-fire.com Series TYB - 2.8,1 5.6., and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage S S General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers described in herein are standard response, standard coverage, decora- tive 5 mm glass bulb-type spray sprin- klers. They are designed for use in light, ordinary, or extra-hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The TY-B Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjust- ment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 8 it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. The Series TY-B 2.8, 5.6, and 8.0 K-fac- tor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contract the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Numbers (SIN) TY1151 ... Upright 2.81K, 1/2 in. NPT TY1251 . . .Pendent 2.8K, 1/2 in. NPT TY3151 ... Upright 5.6K, 1/2 in. NPT TY3251 . . .Pendent 5.61K, 1/2 in. NPT TY4151 ... Upright 8.0K, 3/4 in. NPT 1Y4251 . . .Pendent 8.01K, 3/4 in. NPT TY4851 ... Upright 8.0K, 1/2 in. NPT TY4951 . . .Pendent 8.0K, 1/2 in. NPT JULY 2018 Technical Data Approvals UL and C-UL Listed FM, LPCB, VdS, and NYC Approved Refer to Table A for complete approval infor- mation, including corrosion-resistant status. Maximum Working Pressure Refer to Table B Discharge Coefficient K=2.8 GPM/psi/2 (40,3 LPM/bar") K=5.6 GPM/psi/2 (80,6 LPM/bar") K=8.0 GPM/psi/2 (115,2 LPM/bar½) Temperature Ratings Refer to Table A Finishes Sprinkler: Refer to Table C Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly. . Beryllium Nickel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector .........................Copper Bushing (K=2.8) ....................Bronze TFPI5I 7/16' (11,1 mm) NOMINAL MAKE-IN 2-3/16 (55,6 mm) 1/2' NPT** I WRENCH FLATS CEILING PLATE SEATING SURFACE 2-1/4' (57,2 mm) 1-9/16' (39,7 mm) TFP15I Page 2 of 8 1 - Frame 5 - Compression 2 - Button Screw 3 - Sealing 6 - Deflector* Assembly 7 - Bushing 1 4 - Bulb jj3 2 * Temperature rating is indicated on Deflector. 4 Ii 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. UPRIGHT PENDENT CROSS SECTION FIGURE 1 SERIES TV-B UPRIGHT (TVII51) AND PENDENT (TV1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE 1 - Frame 3 - Sealing 5 - Compression 2 - Button Assembly Screw 4 - Bulb 6 - Deflector* * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on ESCUTCHEON Deflector, special request. PLATE SEATING SURFACE 7L/2 I NOMINAL 7/16' _6 11,1 mm) mm) 2-3/16" MA1E-lN (55,6 mm) fl 1/2 NPT** I WRENCH STYLE 10 -.--- 2-7/8' (73,0 mm) DIA. -.--] FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION ALL FINISHES EXCEPT POLY-STAINLESS WRENCH 1/2' ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated \ SURFACE 4 - Bulb 6 - Deflector* on Deflector. 2-3/16' (55,6 mm) /2' (38,1 mm) IA STYLE 10 2-7/8' (73,0 mm) D RECESSED PENDENT ESCUTCHEON RECESSED PENDENT CROSS SECTION POLY-STAINLESS FINISH ONLY UPRIGHT FIGURE 2 SERIES TV-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE I] 2-7/8" (73,0 mm) DIA. RECESSED PENDENT CROSS SECTION CEILING PLATE SEATING SURFACE /j nm) I 7/16" (11,1 mm) NOMINAL MAKE-IN , 2-3/16" (55,6 mm) 1/2" NPT** I WRENCH FLATS S TFPI5I Page 3 of 8 1 - Frame 3 - Sealing 5 - Compression ESCUTCHEON 2 - Button Assembly Screw PLATE SEATING 4 - Bulb 6 - Deflector* SURFACE 1/2 1 _ _ _1-I ' (12,7 mm) I MAKE-IN FY 2-1/4 (58,7 mm) 1-9/16' NOMINAL 2-5/16' (39,7 mm) I - (57,2mm) 3/4' NPT** f WRENCH STYLE 40 - 2-7/8' (73,0 mm) DIA. FLATS RECESSED UPRIGHT PENDENT ESCUTCHEON RECESSED PENDENT ALL FINISHES EXCEPT POLY-STAINLESS * Temperature rating ** Pipe thread connections per is indicated on ISO 7-1 can be provided on Deflector. special request. CROSS SECTION S UPRIGHT WRENCH 3/4" ESCUTCHEON 1 - Frame 3 - Sealing 5 - Compression *Temperature FLATS NPT PLATE SEATING 2 - Button Assembly Screw rating indicated 1/2" NOMINAL 2J16. (58,7 mm) (12,7 mm) SURFACE 4 - Bulb 6 - Deflector* on Deflector. MAKE-IN I 1 2-1/4' 1-9/16 (57,2 mm) (39,7 mm) I STYLE 40 RECESSED PENDENT ESCUTCHEON POLY-STAINLESS FINISH ONLY FIGURE 3 SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE 1 - Frame 5 - Compression 1 2 - Button Screw 3 - Sealing 6 - Deflector* r 3 Assembly 4 - Bulb * Temperature rating is indicated on Deflector. 4--- 5 ** Pipe thread connections per ISO 7-1 can be 6* provided on special request. UPRIGHT PENDENT CROSS SECTION FIGURE 4 SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE 0 TFPI5I Page 4 of 8 S 2-7/8 DIA. 5/8±1/4' (73,0 mm) 3/4(19,1 mm) I (15,9±6,4 mm) 2-1/4 DIA. I 1/4' (6,4 mm) FACE OF - (57,2 mm) MOUNTING SPRINKLER PLATE 1/8" (3,2 mm) FITTING _r?_1i__ MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-B 3/4' (19,1 mm) FIGURE 5 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH 2-7/8" DIA. 5/8±1/4" - (73,0 mm) - 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF (57,2mm) MOUNTING SPRINKLER c ...) _- PLATE FITTING (3,2 mm) MOUNTING / SURFACE / / CLOSURE SERIES 1-5/16" (33,3 mm) TYB 13/16" (20,6 mm) FIGURE 6 SERIES TV-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH S Poly-Stainless Physical Characteristics Frame ............................Bronze Button ................L316 Stainless Steel* Bulb...............................Glass Compression Screw .....L316 Stainless Steel* Deflector ...................Copper/Bronze Sealing Assembly. Gold Plated Beryllium Nickel w/TEFLON *Type L316 stainless steel (UNS 31603) per ASTM A479/479M or ES EN 1008 WN1.4404. Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the Style 10 or 40 Recessed Escutcheon, as applicable, for recessed pendent installations. Installation The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum S S TFPI5I Page 5 of 8 K Sprinkler Type Temperature Rating Liquid Color Bulb ___________________________ Sprinkler Finish8 _____________ Natural Brass I Chrome Plated Polyesterc _____________ Poly-Stainless Lead Coated I Wax Coated I Wax-Over- I Lead Coated 135°F (57°C) Orange 2.8 1/2 in NPT Upright (TY1151) and Pendent (TY1251) 1, 2, 3 N/A N/Ad 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Figure 1 Blue 360°F(182°C) Mauve 1,2 135°F (57°C) Orange Upright (TY3151) 1,2,3,5 1,2,3,5 155°F (68°C) Red 175°F (79°C) Yellow 5.6 1/2 in. and Pendent (TY3251) Figure 2 1, 2, 3, 4, 5, 6, 7 1,2 Green 1,2,3,5 200°F (93°C) 286°F (141°C) Blue lb, 21b, 3b, 51b ib, 2b, 31b, 5b 360°F (182°C) Mauve I N/A NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY3251)a 1, 2, 3, 4, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 5 286°F(141°C) Blue 1,2 135°F (57°C) Orange 8.0 3/4 in. Upright (TY4151) and Pendent (TY4251) Figure 3 155°F (68°C) Red 1, 2, 3, 4, 5, 6, 7 1,2 1,2,5 1,2,3,5 __ 1,2,5 ___________ 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue ib, 2b, 3b, 5b lb, 2b, 5b 360°F (182°C) Mauve N/A NPT 135°F (57°C) Orange 155°F (68°C) Red Recessed Pendent (TY4251)a 1, 2, 3, 4, 5 1,2 N/A 175°F (79°C) Yellow 200°F (93°C) Green Figure 6 286°F (141°C) Blue 1,2 135°F (57°C) Orange 155°F (68°C) Red 8.0 1/2 in'NPT Upright (TY4851) and Pendent (TY4951) 1,2,3,4,5,6 N/A N/A 175°F (79°C) Yellow 200°F (93°C) Green 286°F (141°C) Blue Figure 4 360°F (182°C) Mauve NOTES Listed by underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by FM Global (FM Approvals). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03). Approved by the City of New York under MEA 354-01-E. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) Approved by the Loss Prevention Certification Board )LPCB Ref. No. 094a/05) Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers. Installed with Style 10(1/2 in. NPT) or Style 40(3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable 150°F (66°C) maximum ceiling temperature Frame and deflector only Not Applicable (N/A) TABLE A SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFPI5I Page 6 of 8 Sprinkler Finish K Type Natural Brass Chrome I Polyester' Lead I Wax I Wax-Over-Lead 1 Plated I Coated Coated Coated 2.8 Upright (TY1151) 1/2 in. and 175 psi (12,1 bar) N/A3 NPT Pendent (TY1251) Upright (TY3151) and 5.6 Pendent (TY3251) 250 psi (17,2 bar)2 1/2 in. or NPT 175 psi (12,1 bar) Recessed Pendent (TY3251) Upright (TY4151) and 175 psi (12,1 bar) 8.0 Pendent (TY4251) 3/4 in. NPT Recessed Pendent 175 psi (12,1 bar) I N/A (TY4251) I 8.0 Upright (TY4851) 1/2 in. and 175 psi (12,1 bar) NPT Pendent (TY4951) NOTES Frame and deflector only The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL), the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL), and the Approval by the City of New York. Not Applicable (N/A) TABLE B SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE S torque of 10 to 20 lb-ft (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series TV-B Upright and Pendent Sprinklers Installation The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 7). For wax-coated sprinklers, use an 8 or 10 in. adjustable wrench. With reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, to the sprinkler wrench flats. Wax Coated Sprinklers When installing wax-coated sprinklers with an adjustable wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. Before wrench tightening the sprin- kler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 inch diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod in order to prevent the installer from being burned. S TFPI5I Page 7 of 8 S S Series TY-B Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 8). With reference to Figure 3 or 4, apply the W-Type 7 Recessed Sprin- kler wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Recessed Pendent Sprinkler and push the Closure over the Mount- ing Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. Refer to the Instal- lation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Automatic sprinkler are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. 9 1 I NATURAL BRASS POLY-STAINLESS GREY 2 ALUMINUM (RAL9007)1 POLYESTER PURE WHITE (RAL9010)2 POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005)3 POLYESTER 6 WAX COATED - 286°F (141°C) MAX 7 LEAD COATED - 8 WAX-OVER-LEAD 286°F (141°C) MAX 9 CHROME PLATED TFPI5I Page 8 of 8 P/N 57 — XXX - X - XXX I I I I I I SPRINKLER I I SIN I FINISH 135 135°F (57°C) 155 155°F (68°C) 175 175-F (79-C) 200 200°F (93°C) 286 286°F (141°C) 360 360-F (182-C) 000 T OPEN4 TEMPERATURE RATING 530 2.8K UPRIGHT (1/2 in. NPT) TY1151 531 2.8K PENDENT (1/2 in. NPT) TY1251 570 5.6K UPRIGHT (1/2 in. NPT) TY3151 571 5.6K PENDENT (1/2 in. NPT) TY3251 590 8.0K UPRIGHT (3/4 in. NPT) TY4151 591 8.0K PENDENT (3/4 in. NPT) TY4251 560 8.0K UPRIGHT (1/2 in. NPT) 1Y4851 561 8.0K PENDENT (1/2 in. NPT) TY4951 NOTES Only available on TY3151, TY3251, TY4151, and TY4251. Eastern Hemisphere sales Only. Available in only 8.0K, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems ("OPEN" indicates sprinkler assembly without glass bulb, button, and sealing assembly). TABLE C SERIES TV-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyCo-fire.Com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or Coating, P/N (Refer to Table C) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench- damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1- 286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F (141°C) sprinklers is the same as for 200°F(93°C) sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 2000F(93°C) sprinkler which is 150°F (66°C). S 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and other information shown were current an of document revision dale and are subject to change without notice. NATIONAL FIRE PROTECTION ASsOCIATION oad NFPA oro ,ogistorsd troderno,ks of National Foe ProSO or As—lotion TEFLON ISO r55i5t50d trademark of DuPont Johnson 010 Controls [SAMMYS® FOR WOOD WOOD -Appl ication Product Features -II Not less than 2" nominal width Wood Flooring No pre-drilling required. A A A l~ Not less than Nut Driver with an 18V cordless (depth or side Wood Joist n Quick to install using the Sammy :I 2) Reduces installation costs. Made in the U.S.A. Watch a video demonshaffon at . www.itwbuildex.com i- #14 Black Nut Driver Part # 8113910 i . #14 SW Red Nut Driver Part # 8114910 1/4' 8002957 1/4" 8003957 1/4" 8004957 3/8" 8007957 3/8" 8008957 JEL 3/8 8068925 3/8 8009925 3/8" 8010957 3/8" 8069925 3/8" 8011925 1/2' 8013925 1/2" 8014925 1/2" 8015925 GST 100 1/4 x 210 (7/16" OSB) 25 125 GST 200 1/4x2 1760 (Fir) 25 125 GST 300 1/4 x 3" 2060 (Fir) 25 125 GST 10 1/4x 1" 300 25 125 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 GST 20-SS 1/4x2" 1760 (Fir) 850 25 125 GST 25-380 3/8x2-112" 2113 (Fir) 1500 25 125 GST 30 1/4x3" 2060 (Fir) 1500 1475 - 25 125 GST 30-SS1/4x3" 2060 (Fir) 25 125 GST 40 1/4x4 2180 (Fir) 25 125 GST 2 -. 1/4o 2" 1760 (Fir) 25 125 GST 2.5-380 3/8 x 2-1/2" 2113 (Fir) 25 125 GST 3 1/4 x 3" 2275 (Fir) 25 125 %W -MmADE ImN"U.S7, V SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. MINf41IL1TASi Not less than 2" nominal width (1-1/2') up to 3-1/2' pipe; not less than 3" 2-1/21 nominal width 4" & 5" pipe 4 Minimum 2-112" from bottom for branch lines. Minimum 3" from bot- tom for main lines. Exception: This requirement shall not apply to 2" or thicker nailing strips resting on top of steel beams. No pre-drilling required. Quick to install using the Sammy Floor 7oist Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. Watch a vide demonstration at - www.itwbuildex.com . Q a #14 SW Red Nut Driver Part #8114910 k:r.u.]uM.1uINT ' 114 8019957 SWG 200 3/8 8020957 SWG 10 C 3/8 8021957 SWG 20 3/8 8073925 SWG 20 SS 3/8" 8022925 SWG 25-380 - 3/8' 8023925 SWG 30 - May require pre-drilling: consult joist msnutacturer. 114x2" 1725 (Fir) 1/4x 1 622 (Fr) 1/402 1725 (Fir) 1/4x2 1725 (Fir) 3/80 2-1/2" 2249 (Fir) 1/403" 1884 (Fir) 25 125 300 25 125 1050 25 125 850 25 125 1500 25 125 . 25 125 SAMMYS S WIVEL :! HE' '.J;1WOOD Swivel AppUcation Application Product Features distortion of threaded rod. IT Eliminates HAMM #14 Black -Approvals rt Model Screw JFh10 Ultimate UL Test Load FM Test Min Box Case Nut Driver -i: ''s' 3/8" 8139957 SH-GST20 1/402" 1257 (Fir) 1050 1475 25 125 Part #8113910 1903 Din,. Lumber I 3/8"' 8269957 SH-GST/CST 20 5/16x1-3/4" 1406 @ 45off vertical 1500 850 @45 25 125 J Dim. Lumber I 903 Dim. Lumber 1/2" 8303957 SH-GST/CST 2.0 5/16 x 1-3/4" 1406 @ 45"off vertical 25 125 L Dim. Lumber #14 SH Orange May require pre-drilling; conouit)oist manufacturer. Nut Driver Part # 8273910 S Victaulic® FireLockTM Outlet-I A taui.cr Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 -2 1/2"/DN32—DN65 Threaded Outlet Sizes: 1/2"/DN15, 347DN20, and 17DN25 NOTE IGS Grooved 1'/DN25 Outlets available for this product. See publication 10,54. Maximum Working Pressure 300 psi/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS .... NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location I J Spec Section Paragraph . Submitted By Date Approved Date victaulic.com 10.52 3355 Rev H Updated 06/2018 0 2018 Victaulic Company. All rights reserved. 1 4tauIiice victaulic.com 3.0 SPECIFICATIONS - MATERIAL Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade 65-45-15, is available upon special request. Housing Coating: (specify choice) LI Orange enamel (North America, Latin America, Asia Pacific). LI Red enamel (Europe). LI Optional: Contact Victaulic with your requirements for other coatings. Gasket': LI Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40T/-40°C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible, Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: LI Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). S 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 2 \4taulicr victaulic.com 4.0 DIMENSIONS S Style 922 Style 922 Size Bolt/Nut Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W Y Z (Each) inches inches inches inches inches inches inches inches lb DN mm - mm mm mm mm mm mm kg 1¼ 1/2 1.660 0.840 1.30 1.83 1.10 3.87 2.56 1 DN32 42.4 21.3 2 x 1 33 47 28 98 65 0.5 1.28 1.83 1.10 3.87 2.56 1 3/4 1.050 DN20 26.9 2 X 1 33 47 28 98 65 0.5 1.52 2.18 1.10 3.87 2.56 1 1 1.315 DN25 2 Xl 39 55 28 98 65 0.5 1½ 1/2 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 2 x1 36 50 31 104 65 0.5 1.40 1.95 1.22 4.08 2.56 1 3/4 1.050 DN20 26.9 2 X 1 36 50 31 104 65 0.5 1.64 2.30 1.22 4.08 2.56 1 1 1.315 DN25 33.72 x 1 42 58 31 104 65 0.6 2 1/2 1 2.375 0.840 1.66 2.19 1.46 4.60 2.56 1 50 DN15J 60.3 21.3 2 x1 42 56 37 117 65 0.6 3/4 1.050 1.64 2.19 1.46 4.60 2.56 1 DN2O 26.9 2 x 1 42 56 37 117 65 0.6 1 1 1.315 1.88 2.54 1.46 4.60 2.56 2 0N25 2 x1 48 65 37 117 65 0.7 21/2 1/2 2.875 0.840 1.91 2.44 1.71 5.40 2.56 2 DN15 73.0 21.3 2 x1 49 62 1 43 137 65 0.7 1.89 2.44 1.71 5.40 2.56 2 3/4 1.050 DN20 26.9 2 X 1 48 62 1 43 137 65 0.7 2.13 2.79 1.71 5.40 2.56 2 1 1.315 DN25 2 xl 54 71 43 137 65 0.7 DN65 1/2 3.000 0.840 2 x1 1.91 2.44 1.71 5.50 2.56 2 DN15 76.1 21.3 49 i 62 43 140 65 0.7 1 1.89 2.44 1.71 5.50 2.56 2 3/4 1.050 DN20 26.9 2 j 48 62 43 140 65 0.7 2.13 1 2.79 1.71 5.50 2.56 2 1 1.315 DN25 2 X 1 54 1 71 1 43 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Rater to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 3 '\Jtauuac victaulic.com 5.0 PERFORMANCE Style 922 Equivalent Length of linch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120) Run Size x Outlet Size Threaded Grooved' inches feet feet DIN meters meters 1'/4 1 8.5 12.5 DN32 DN25 2.6 3.8 1½ 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DN50 DN25 2.6 3.8 21/2 1 8.5 12.5 0N25 2.6 3.8 1 8.5 12.5 0N65 0N25 2.6 3.8 Hazen-Williams coefficient of friction is 120. 1 FireLockTM Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm All Outlet Sizes ¼ 1 30 32 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4 'jtauiac F, victaulic.com 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi ON kPa i kPa kPa kPa kPa kPa 1 1/4 x 1/2 300 300 300 232 232 232 DN32XDN15 2068 2068 2068 1600 1600 1600 1 1/4 x 3/4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1 1/4X 1 300 300 300 232 1 232 232 DN32XDN25 2068 2068 2068 1600 1600 1600 1 1/2 x 1/2 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1 1/2 x '/4 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1 1/2 x 1 300 300 300 232 232 232 ON40XDN25 2068 2068 2068 1600 1600 1600 2x½ 300 300 300 232 232 232 DN50XDN15 2068 2068 2068 1600 i 1600 1600 2x3/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2 x 1 300 300 300 232 232 232 DN50XDN25 2068 2068 2068 1600 1600 1600 2½x½ 300 300 300 232 232 232 2068 2068 2068 1600 - 1600 1600 2½x1/4 300 300 300 232 i 232 232 2068 2068 2068 1600 1600 1600 2½x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 11 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN25 - - 2068 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information. 7.2 REFERENCE MATERIALS 05.01 Victaulic Seal Selection Guide 29.01; Victaulic Terms and Conditions of Sale -100: Installation Instructions 1-922 Installation Instructions FireLockry Outlet-T User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as lathe suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, adoice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victuolic specifications. All products to be installed is accordance with current Victaulic installation/assembly instructions. Victaulic reserves the rigirl to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be mode to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on Wechat. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its alliliated entities, in the U.S. arid/or other countries. 10.52 3355 Rev H Updated 06/2018 © 2018 Victaulic Company. All rights reserved. victaulic.com 4tauiicr F P P Description Manufactured from .020" white coated aluminum. All sign types are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NEPAl 3 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation directly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Installation Specifications Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the Material: .020" aluminum with sign on the area being identified. Since all of the above mentioned signs are removable plastic coating predrilled at all four corners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the appropriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to x 6" the base material. (The 9" x 7" Fire Alarm Bell sign must be drilled with a s/a" hole x 7" if it is to be attached directly to the bell gong.) 8.5" xli" 7" Round See current catalog for a full listing of all available signs. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. Fig. 200-21/2 to 200-8 0 10 10 0. Fig. 200 Part No. Pipe Size in. (mm) Rod Size in. A (mm) in. B (mm) Approx. Wt./100 lbs. (kg) 200-1/2 1/2' (15) /8'-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-I4 3/4' (20) /8°-16 31/8' (79.4) 21/2' (63.5) . . 111 (5.0) 200-1 1° (25) /8°-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200_1114 11/4" (32) /"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) /8"-16 3/8" (98.4) 2/8 (73.0) 14 (6.4) 200-2 2" (501 /8°-16 41/2" (114.3) 3' (76.3) 15 (6.9) 200-21/2 21/2' (65) 3/8 -16 5/8" (142.9) 41/8' (104.7) 21 (12.3) 200-3 3" (15) 3/8 -16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-31/2 31/2" (90) /8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 2004 4" (100) /8"-16 7/8" (187.3) 5" 1121.01 35 (16.0) 200-5 (125) 1/2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 (150) 1/2"13 101/8" (257.2) 6/4" 1171.41 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) S Fig. 200S Pipe Hangers Fig. 200 - "Trimline" Adjustable Band Hanger (B-Line Fig. B317ONF) ®TOLCO Fig. 200F - Trimline" Adjustable Band Hanger with Felt Lining (B-Line Fig. B311ONFF) ceus Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (B-Line Fig. B311ONFC) LISTED Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. / (21/2" )65mm) thru 8" (200mm)) Spring tension on nut holds it securely in " hanger before before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2' (15mm) thru 8" (200mm)) in the USA (UI) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4' (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications VAN-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel r.. materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size L Designed to meet or exceed requirements of Fig. 200C Fig. 200F All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Fire Protection Solutions 21 by E.TN Fig. 25 - Surge Restrainer Size Range: - One size fits 3/4 (20mm) thru 2 (40mm) pipe. Material: - Pre-Galvanized Steel Function: - Designed to be used in conjunction with Fig. 200 band hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals: - Underwriters Laboratories Listed only when used with band hanger Fig. 200, in the USA (UL) and Canada (cUL). Finish: Pre-Galvanized Order By: Figure number and band hanger, size from 3/4 (20mm) thru 2 (40mm). Patent #5,344,108 c®uS L:JJ LISTED S All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Threaded Accessories B3205 - Threaded Rod (right-hand threads - both ends) (TOLCO Fig. 103) B32051 - Threaded Rod (right & left hand threads) Size Range: 3/8 -16 thru 3-4 rod Material: Steel Function: Recommended for use as a hanger support in hanger assemblies. Rod is threaded on both ends with right hand threads of the length shown. Also available with left and right hand threads - specify Fig. B3205L when ordering. Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish ®TOLCO Specify Lengt TLize TL Standard Design Load Thread Size Thread Length TI 650°F (343°C) 750°F (399°C) Part No. A in. (mm) Lbs. )kN) Lbs. (kN) B3205-318 x 1 /8'-16 21/2 (63.5) 730 (3.25) 572 (2.54) B3205-1 /2 x 1 1/2'.13 21/2 (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x L /811-11 21/2 (63.5) 2160 (9.61) 1692 (7.52) B3205-314x 'L 3/4 -10 3 (76.2) 3230 (14.37) 2530 (11.25) B3205-71e x 'I, /8-9 31/2 (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. AIR - All Threaded Rod - 120" (3.05m) Lengths (TOLCO Fig. 100) Fig. 99 - All Threaded Rod Cut To Length Size Range: /8'-16 thru 11/2"-6 rod in 120" lengths or cut to length Material: Steel Maximum Temperature: 750°F (399°C) Finish: Plain or Electro-Galvanized. Contact B-Line for alternative finishes and materials. Order By: Figure number, rod size, length and finish Part No. - Size x Length ATR Fig. 99 Threads Per Inch Recommended Load Lbs. (kN) Approx. Wt./100 Ft. Lbs. (kg) AIR 1/4" x 120 99.1/4" x length 20 240 (1.07) 12 (5.44) AIR /8" x 120 99.3/8" x length 16 730 (3.24) 29 (13.15) AIR 1/2" x 120 99-1/2" x length 13 1350 (6.00) 53 (24.04) AIR 5/8" x 120 99_5/g" x length 11 2160 (9.60) 89 (40.37) AIR 3/4" X 120 99.3/4" x length 10 3230 (14.37) 123 (55.79) AIR /8" x 120 99-/8" x length 9 4480 (19.93) 170 (71.11) For larger sizes consult full line pipe hanger catalog All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Revised 4/28/2074 94 Fire Protection Solutions by [4j * I a' •• oll bs..± Y a•os..'i. ' *•' *•t iss*i• \ •S•OOS•SOSS••I •••• ••••osj •S• •SSØ•tisr. ••••••••••••• . g " '4•• • .. • . . . • - '\ '. '. •. (f L r :1 1 AWI L • . - -. - - I ri r E R fsi ^ -r I CIO rsi AM I, - - ----- - Building Connections That Last AUGUST 2014 -.- - - For the most current prockict/pricing information on Anvil products, please visit our website at www.anvilinticom - V) 1WIL IfSJTE LI Building Connections That Last The unmatcAed range of domestic and globaly-sourced products for fire protection piping systems offered by Anvil provides versatile and dependable performance for a wide range of applications. Anvil products are UL/ULC Listed and FM Approved. Anvil combines the latest technology, up-to date fire protection ratings, recognized manufacturing expertise and a trusted history that has made Anvil the go-to source for fire protection piping products. r 717 7 7,z_~ Anvil Cast Iron & Malleable Iron Threaded Fittings Manufactured in Columbia, PA USA, Anvil offers the most complete line of Cast Iron and Malleable Iron Threaded Fittings in the industry. Our versatile range of fittings is designed to provide connection options for different applications and environments. Cast Iron (Gray Iron) Threaded Fittings are manufactured in accordance with ASME/ANSI B14.4 and are UL/ULC listed and FM approved. Malleable Iron Fittings are manufactured in accordance with ASME/ANSI B 16.3 and Unions ASME/ANSI B 16.39 and are available in Class 150, Class 250, and Class 300 UL/ULC listed and FM approved. In both classes, all Elbows and Tees /8 and larger are 100% air tested at a minimum of 100 psi (6.9 bar). Cast Iron Flanged Fittings are manufactured in accordance with ASME B16.1 and are available in both Class 125 and Class 250. Anvil Steel Pipe Nipples & Steel Anvil offers a variety of Steel Pipe Nipples and Steel Pipe Couplings for the fire protection industry. S Anvil's Steel Pipe Nipples are manufactured in accordance with ASTM/ ANSI A 733 welded and seamless carbon steel pipe nipples. Materials include black and hot-dipped galvanized finishes. Anvil manufactures a wide range of stock pipe nipples in /a" diameter through 8" diameter close through 72' inch length in half-inch increments. We also offer Pipe Couplings standard nipple packs ranging from one each (close to 6) and standard six packs which offer multiple counts of each. Cartons are packed with handles for easy carrying. Steel Pipe Couplings are manufactured in accordance with ASTM specification A 865. Straight-tapped couplings range in size from 1/81? NPS through 2" NPS, while 21/2 NPS and larger are taper tapped. <E~~D SPF Ductile Iron & Cast Iron Threaded Fittings SPF Ductile Iron Threaded Fittings are UL/ ULC Listed and FM Approved for 500 psi service. These fittings provide a dependable threaded connection and are available in a range of styles and Ductile Iron conform to ANSI 2!II4LE ::: Iron Threaded Fittings are UL/ULC ' V Listed and FM Approved for 300 psi service. -- These fittings are available in a range of V * styles and specifications. All SPF Cast Iron V t.•; V Threaded Fittings dimensions conform to ANSI B16.4 requirements, and threads are c®us '3 NPT per ANSI/ASME 131.20.1. LISTED APPROVED www.anvilintl.com Fire Products 3