HomeMy WebLinkAbout2011 PALOMAR AIRPORT RD; ; FA160074; Permit12/16/21, 3:33 PM - FA160074 Permit Data City of Carlsbad Fire Alarm Permit 2011 PALOMAR Job Address: AIRPORT RD Permit Type: FALARM Parcel No: 2130612600 Lot #: 0 Permit No: FA160074 Status: ISSUED Applied 10/27/2016 Approved: 10/27/2016 Reference No.: Issued: 10/27/2016 PC #: Inspector: Project Title: FA160074 INSTALL A CELLUALAR COMMUNIATOR AT THE FACU FOR CENTRAL STATION MONITORING. THERE ARE NO CHANGES TO THE EXISTING FIRE ALARM SYSTEM. Applicant: Owner: BAY ALARM COMPANY P T CARLSBAD ASSOCIATES DAN ANDERSON C/O GENERAL PROP MGNT 8205 RONSON RD, ST F 9285 DOWDY DR #101 SAN DIEGO, CA 92111 SAN DIEGO CA 618-718-0186 Fees ($) TAdd'l Fees ($) r Total ($) J Balance(s) 314 0 314 0 1/1 8205 Ronson Rd. Ste F San Diego, CA 92111 (800) 470-1000 Contractor License # 880138 I. PROTECTED PREMISE Palomar Triad Building 2011 Palomar Airport Rd. Carlsbad, Ca 92009 H. MONITORING COMPANY Bay Alarm Company 5130 Commercial Circle Concord, CA 94520 800-470-1000 California Alarm Operating License Number: ACO28 Ill. EQUIPMENT SUPPLIER & INSTALLER 8205 Ronson Road, Suite F San Diego, CA 921111(800)470-1000 Contractor License # 880138 FA1 60074 2011 PALOMAR AIRPORT RD Honeywell IPGSM-4G Single or Dual Path Commercial Fire Communicator General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel (FACP) that has a built-in dialer. This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panels Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has the ability to route messages using AlarmNet-1 and 800 PLUS services, providing true redundancy and multipath message delivery. Alternative communication methods are critical in the market- place due to VoIP (Voice over IP), migration from POTS (Plain Old Telephone Service) and growth of digital radio networks. The IPGSM-4G's single path communications solution allows one technology to be used (either IP or cellular) to provide the appropriate connectivity to a central station. For added reliabil- ity, our exclusive dual path solution allows both technologies (IP and cellular) to be used together for maximum survivability or for local jurisdiction requirements that specify a dual tech- nology system. The IPGSM-4G is designed to operate over the most common cellular networks including 2G, 3G and 4G. Its multi-GSM plat- form technology automatically chooses the best available cel- lular signal in the area based on signal strength and seamlessly self-adjusts to maintain critical life safety communi- cation. In addition, it connects to any type of customer pro- vided Ethernet 10/100 base network connection (LAN or WAN), DSL model or cable modem. Our selectable reporting path feature allows the radio to be configured for a single or dual path solution as well as the appropriate supervision inter- vals based on NFPA 72 requirements. (See diagram below for selectable paths and supervision timing intervals.) Selectable Path Description Supervision Times 2010 GSM Single Path (cellular only) 5 minutes 2010 IP Single Path (IP only) 5 minutes 2010 IF & GSM Dual Path (IP and cellular) 24 hours 2013 GSM Single Path (cellular only) 1 hour 2013 IP Single Path (IP only) 1 hour 2013 IF & GSM Dual Path (IF and cellular) 6 hours Features Saves the cost of two dedicated phone lines. Single or dual path communications. (Can communicate to central station using cellular technology, internet or both. Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Multi-GSM platform compatibility for 2G, 3G and 4G net- works. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) GPRS (2G). Selectable reporting paths and supervision intervals to meet NFPA 72, chapter 26 requirements. (Compliant with NFPA 722010 and 2013 supervision requirements.) Works over any type of customer provided Ethernet 10/100 based network connection (LAN or WAN), DSL modem or cable modem. Data transmits over standard contact-ID protocol but is secured with the industry's advanced encryption standard (AES 256 bit). Supports both dynamic (DHCP) or Public and Private Static IP addressing. Built-In Power Supply module: On board charging circuit design accommodates back-up battery. Includes primary power and battery supervision. Diagnostic LEDs: Signal strength and status indicators. Reliable connection: IP and GSM connection tested every day. QOS: Quality of Service diagnostics via AlarmNet conveys vital communicator information including when message was received, signal strength, and message path used. 7720P Hand-held programmer for easy setup. Operation When an event occurs, the Fire Alarm Control Panel goes off hook to dial the central station. The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire panel with a dial tone. When the fire panel detects the dial tone, it begins dialing the central station. After the dialing is completed, the Dialer Capture Module returns a handshake to the fire panel. The fire panel then sends the contact ID reports to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the IPGSM communications module. When all the reports are sent, the fire panel goes on-hook. The IPGSM communica- tions module then transmits the messages to the central sta- tion either over the GSM network or the Internet (dependent on configuration). Easy to Program The IPGSM-4G communicator can be pre-programmed using the 7720P programmer to enter all central-station information. This is saved to the IPGSM-4G communicator panel memory. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the AlarmNet receiver. .For most installations, the only required parameters are: Primary City ID (two digits) obtained from your monitoring station. Primary Central Station ID (two digits) obtained from your monitoring station. Primary Subscriber ID (four digits) obtained from your mon- itoring station. Communication Module's MAC ID, and MAC CRC number located on outside of box, and inside of the module. All of these parameters are assigned by the monitoring station. NOTE: Some assembly is required. See Installation and Setup Guide #800-12454 for full details. Fire Communicator Capability The IPGSM-4G is compatible with fire panels that use the Contact ID communications format as described in the SIA DC-05 standard. AlarmNet Honeywell's AlarmNet has been the nationwide leader in alarm communications technology since 1986. A reliable alter- native for the transmission of alarm signals, our radio network provides extensive coverage in the United States and Canada. AlarmNet Network Control center processes signals from pow- erful servers in multiple locations equipped with 24/7 infra- structure support. The AlarmNet network consist of redundant hardware servers, hot back-up databases and generators with battery back-up at all locations to ensure continuity of service. Signals from Alarm-Net are transmitted to the central station's receivers using multiple communications paths consisting of the Internet, radio network or toll-free POTS service. Installation Requirements UL COMPLIANCE To meet UL864/NFPA, ensure the following: IPGSM-4G must be installed in accordance with NFPA (National Fire Protection Association) standards 70 and 72. IPGSM-43 must be mounted in the same room and within 20 feet of the fire panel. IPGSM-4G, and all equipment used for the IP connection (such as the router, hub, modem, etc.) shall be listed, must be powered from an un-switched branch circuit, and be pro- vided with appropriate standby power. IPGSM-4G must use the 7AH battery (not supplied) to pro- vide 24-hour backup capability. Electrical Specifications Transformer: - Primary 120 VAC, 60Hz, 0.5A. - Secondary: 18VDC, 50VA. Battery: - One 12 V 7.0 AH lead-acid battery (not supplied). - Battery charging current: 1 Amp maximum. - Battery discharge current: Standby 230mA, Active 950mA. Cabinet Specifications Dimensions: 14.875' H x 12.75" W x 3.0' D (37.8 cm H x 32.4 cm W x 7.6 cm D). Color: Red. Shipping Specifications Weight: 5.3 lbs. (6.94 kg). Dimensions: 15.625 H x 13.79" W x 9.25° D (39.7 cm H x 34.9 cm W x 23.9 cm D) Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93%* 2% RH (non condensing at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic com- ponents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15 - 270C/60 - 80°F. Product Line Information IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- cator Panel. Includes red cabinet with Ademco key and lock, wall outlet box, Dialer Capture Module, IGSM Communications Module, antenna & mounting adapter, PowerBoosti power supply, LED display board, transformer, manual, & required screws, cables, etc. Antenna Kits GSM-ANT3DB25KT: 25 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 25' RF cable. GSM-ANT3DB50KT: 50 ft. antenna kit. Includes GSM-ANT3DB, WA7626-CA adapter cable, and a 50' RF cable. Antenna External Hardware GSM-ANT3DB: 3db gain external/remote antenna. WA7626-CA: SNA to N Adapter. 7626-50HC: 50 ft. antenna cable, low loss. 7626-25HC: 25 ft. antenna cable, low loss. NOTE: The GSM-ANT3DB and the WA 7626-CA are both required for installing an external antenna along with the necessary cable needed (7626-50HC: 50 ft. or 7626-25HC: 25 ft.) Other Accessories 7720P: IPGSM-4G hand held programmer. HPTCOVER: Plug in transformer box for IPGSM communicator. BAT-1270: Battery 12 Volts, 7 AH, sealed. Agency Listings and Approvals The listings and approvals below apply to the basic IPGSM-4G communicator panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S789. CSFM: 7300-1645:0199. FDNY: COA #6150. Page 2 of 3— DH-60769:C • 4/28/14 www.honeywelI.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot coverall specific applications or anticipate all requirements. All specifications are subject to change without notice. ©2014 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell 12 Clintonville Road 1(877) HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywelI.com www.honeywellpower.com DH-60769:C April 2014 Made in the U.S.A. Iso 9001 ® U.S. Registered Trademark 2014 Honeywell International Inc. 111111111111111119 A Page 3of 3 QUALITY SYSTEMS Honeywell Honeywell Honeywell Life Safety 12 Clintonville Road Northford, CT 06472 IPGSM-4G Commercial Fire Communicator After completing the setup installation using IPGSM-4G Installation and Setup Guide #800-12454 7/12 Rev. B, perform the following steps for inspection and testing a unit: Inspection and testing: lnitial/Reacceptance/ Semiannually A. Visual inspections: Antenna secured and connected to the iGSM Communications Module LED Display board secured Dialer Capture Module with Telco 1 and Telco 2 cables installed from Fire Alarm Control Panel iGSM Communications Module secured, Ethernet cable installed PowerBoosti secured, verified Earth Ground Ferrite Filter installed Transformer, 18 VAC secured Battery (7Ah) shall be inspected for corrosion and leakage Confirm all wiring terminals and connectors are tight Confirm all wiring secured with cable ties Ensure the cabinet door lock is installed and functioning B. Quiescent Operation Checks: Refer to Setup Guide for location of LEDs 1) AC ON (Green) viewed from outside door or bottom LED on the LED Display board 2) iGSM Communications Module, Ethernet cable installed Green Status LED - off Yellow Status LED - flashing Red Status LED - off Signal Strength LEDs - one red, two yellow, and at least one green lit solid Green Ethernet LED - on 3) PowerBoosti Green AC LED - on Green Active LED - flashing 4) Dialer Capture Module Green LED - on Red LED - flashing IPGSM-4G Inspection and Test Page 1/2 03/22/2013 C. Test System on Secondary Power (Battery) Notify the central station that a test will be conducted. Disconnect Transformer, 18 VAC Verify PowerBoosti AC LED OFF Close and lock the cabinet cover Activate an Alarm event from the Fire Alarm Control Panel Restore the Alarm event Activate an Supervisory event from the Fire Alarm Control Panel Restore the Supervisory event Activate an Trouble event from the Fire Alarm Control Panel Restore the Trouble event Restore AC power (Transformer) Call central station to confirm receipt of the above events D. Test System on Primary Power Notify the central station that a test will be conducted. Verify Transformer, 18 VAC connected Verify PowerBoosti AC LED ON Close and lock the cabinet cover Activate an Alarm event from the Fire Alarm Control Panel Restore the Alarm event Activate an Supervisory event from the Fire Alarm Control Panel Restore the Supervisory event Activate an Trouble event from the Fire Alarm Control Panel Restore the Trouble event Call central station to confirm receipt of the above events E. Test Battery Failure and Radio Fault Supervision Notify the central station that a test will be conducted. Disconnect battery Verify PowerBoosti AC LED ON Close and lock the cabinet cover Wait 60 seconds Verify Low Battery LED is lit Fire Alarm Control Panel should indicate Telco line 2 fault within 200 seconds Disconnect Telco line I from the panel Fire Alarm Control Panel should indicate Telco line 1 fault within 200 seconds Reconnect Telco line 1 Reconnect battery Verify Low Battery LED is off Call central station to confirm receipt of Telco 2 fault and restore F. IP/GSM mode 24 hour daily Test report event 1) Call central station for confirmation of the 24 hour daily test report event IPGSM-4G Inspection and Test Page 2/2 03/22/2013 a - CUSTOM DOCUMENT ENCLOSURE - 1, SYSTEM [0 Modified Mier BW-1 06R for Bay Alarm nCUIE 12"W x 12"H x 4"D Durable Red Texture Powder-Coat "SYSTEM RECORD DOCUMENTS" graphic printed in white, on two lines, on the door Rugged construction & 10.5-inch, one-piece, piano hinge for added strength Key holes for quick and easy mounting 1/4-Turn Thumb-Latch installed, as well as holes in place for bolting the door shut. Will also work with Mier's cam locks 1 TIm RECaRD Two electrical knockouts on left side, right side, and back as well as one electrical knockout on top and on bottom Additional customization of this enclosure, or assistance in designing a new model, including color and/or graphics, is available by calling or emailing Mier Products,lnc. LW _____ 800-473-0213 1 infoQmierproducts.com I www.mierproducts.com CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1645:0199 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@Honeywell.com DESIGN: Models iPGSM-COM, iPGSM-DP, iPGSM-4G and *IGSMCFP4G Internet and Digital Cellular Fire Communicators. Units are suitable for residential and commercial applications. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a control unit accessory for use with separately listed compatible commercial and residential fire alarm control units. *Model IGSMCFP4G is intended for use with specific Honeywell Security control units that employ the ECP bus. Refer to listee's installation Instruction Manual for details. NOTE: Burglary and other non-fire functions were not examined. iPGSM-COM, iPGSM-DP formerly listed in 7300-1645:0183. *Rev 07-01-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division