Loading...
HomeMy WebLinkAbout2016 PALOMAR AIRPORT RD; ; FPC2017-0057; PermitPrint Date: 12/16/2021 Job Address: 2016 PALOMAR AIRPORT RD, Permit Type: FIRE-Construction Commercial Parcel #: 2130201800 Valuation: $19,766.75 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: PERMIT REPORT 4L(7city of Carlsbad CARLSBAD, CA 92011-4400 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2017-0057 Status: Closed - Finaled Applied: 03/01/2017 Issued: 03/01/2017 Finaled Close Out: 02/03/2021 Inspector: Final Inspection: Project Title: Description: QUALCOMM PMR.B -SPRINKLER 11<100 HEADS (6) CONFERENCE ROOM ON 2ND FLOOR FPContractor: TITAN FIRE PROTECTION INC 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 6 heads or less $121.00 Total Fees: $121.00 Total Payments To Date: $121.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov f-TC-20 001 ~---~ A CIITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 17-161 QUALCOM PMR.B CONFERENCE RM. T.I. 2016 PALOMAR AIRPORT RD. CARLSBAD, CA 92008 FireLock® V27, K5.6 JtauIicr Models V2703, V2707, V2704, V2708 40.10 Standard Spray Technical Specifications: Upright, Pendent and Recessed Pendent Standard and Quick Response Models: V2703, V2704, V2707, V2708 Style: Pendent Upright or Recessed Pendent Nominal Orifice Size: 1/2713 mm 'i K Factor: 5.61mp./8.1S.I.' 1 Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) V2703/V2704 V2707/V2708 V2707/V2708 • 250 psi/1725 kPa (UL) Upright Pendent Recessed Pendent Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Approvals/Listings: Mm. Operating Pressure: C ®uS <&> LPCB 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I41 /19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 02014 Victaulic Company. All rights reserved. 1 uctauliC victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS 051000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: 11 Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: LII Plain Brass El Chrome plated White painted3 El Black painted3 El Custom painted3 El Proprietary Nickel Teflon2 coating3 El VC-250 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 JtauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor 5.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings P/C" 135°F/57°C 135°F/57°C 1350F/570C 1350F/570C 1350F/57°C 1550F/68°C 1550F/68°C 1550F/680C 1550F/680C 155°F/68°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68"C 200°F/93°C 200°F/930C 200°F/930C 200°F/930C 200°F/930C 175°F/79°C 286°F/1410C 286°F/1410C 286°F/1410C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 1350F/570C 135°F/57°C 135"F/57°C 135°F/570C 1550F/68°C 1550F/680C 135°F/57° C 155 °F/68°C 155°F/68°C 135°F/570C FM 175°F/79°C 175°F/79°C 155°F/68°C 1750F/79°C 1750F/790C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/1410C 286°F/1410C 200°F/930C 286°F/141°C 2860F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57"C 135°F/57°C 1550F/680C 155°F/68°C 155°F/68°C 1550F/68°C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 1750F/790C 1750F/790C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/930C 200°F/93°C 175°F/79"C 286°F/1410C 286°F/1410C 2860F/141°C 286°F/141°C 286°F/1410C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 1350F/570C 135°F/57°C 135°F/57°C 1350F/57°C 155°F/68°C 155°F/68°C 155°F/680C 155°F/68°C 1550F/680C 135°F/57°C CSFM 7690-0531:112 1750F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/1410C 286°F/1410C 286°F/141°C 2860F/1410C 200°F/93°C 360°F/182°C 360°F/1820C 135°F/57°C 1550F/68°C 1350F/570C LPCB 175°F/79 °C None None 155"F/68°C None None 200°F/930C 175°F/79°C 286°F/141°C 200°F/93°C 135°F/57°C 1350F/570C 135°F/570C 1350F/570C 155°F/68°C 155°F/68°C 135°F/57°C 1550F/68°C 155°F/680C 135°F/57°C VNI IPO 175°F/79°C 1750F/79°C 155°F/680C 175°F/79"C 175°F/79°C 1550F/680C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/1410C 200°F/930C 286°F/141°C 286°F/1410C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/680C 155°F/68°C None 1550F/68°C 155°F/680C None 200°F/93°C 200°F/930C 200°F/93°C 200°F/930C 135°F/57°C 155°F/68°C VdS 175°F/79 °C None None 175°F/79°C None None 200°F/930C 286°F/141"C 360°F/1820C 135°F/57°C 155°F/68°C CE 175°F/79°C None None 1750F/79"C None None 200°F/93°C 200°F/930C 286°F/1410C 360"F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with /2" adjustment escutcheon only - quick response Note Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 3 '/tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: 2 60 60 Standard Pendent - Standard Upright - V2707. V2708 V2703, V2704 2W/60 mm Max. Hole 2/5l mm Mm. Hole 17 mm Typical CeilingTile 1;.;'.c7j a // 30 1EIC/ -Finished Surface 30nm 43 mrr MAXIMUM RECESS 2A/ 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/60 mm Max. Hole 2751 mm Min. Hole Typical Ceiling Tile 24mm 4 \—Finished Surface T _24 m __ MAXIMUM RECESS 215A/ 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Vlctaulic Company. All rights reserved. victaulic.com 4 \4taulicr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns — Trajectory —Z. - ,t.% 't,4fl -- - - - - - - -- * ILIIIIIIIi1'L± 2' 4' 10, 12' 14' 0.6,,, 1,2,,, 1.8,1, 2.4,, 3.enl 3.70, 4,30,1 Models V2703, V2704 K5.6 Standard Upright Distribution Patterns -Trajectory 2' 4' 6' 8' 10' 12' 14' 16' 0.6,0 1.2,,, 1.8,,, 2.40, 3.0,0 37, 4,3,0 4.9m NOTES: Data shown is approximate and can vary due to differences in installation, These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties, All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. j updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 4tauIic LI 10, 30 8' 2.4,,, 6 I.E. 4, 12fl, 2' O.61n 8' 2.4m 6' I.B. 4, I.2rn 2' 0.6,1, a 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - oFtoC Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F1571C 100°F/38°C Orange Ordinary C 155°F168°C 100°F/38°C Red Intermediate E 175°F/79°C 150°F165°C Yellow Intermediate F 2000F/93°C 150°F/65°C Green High J 286°F/1410C 2250F8/107°C Blue Extra High K 360°F/182°C 300°F/149°C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707,V2708Pendent / / V2707, V2708 Recessed Pendent / - V2703, V2704 Upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: WE 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our websito at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installatioe/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. it A—c—ta—ulicr victaulic.com 6 FireLock® Escutcheons Victaulic FireLock Escutcheons are intended for use with Victaulic FireLock V24, V27, V29, V33, V34 and V36 recessed, flush, and extended pendent sprinklers. They are intended for use only with Victaulic FireLock sprinklers. Agency Approvals and Listings for Victaulic FireLock sprinklers require the use of Victaulic FireLock escutcheons exclusively. FireLock escutcheons are not Listed or Approved for use with any sprinklers other than Victaulic FireLock sprinklers. FireLock escutcheons are available in various finishes to meet many design requirements and are intended only for use with Victaulic sprinklers. Please reference the 1-40 Installation Manual before installing any product. NOTE: The V33 and V36 escutcheons are offered as part of a pre-assembled sprinkler product and are not available for individual purchase. V29 EXTENDED V29 FLUSH ESCUTCHEON ESCUTCHEON V27 AND V34 RECESSED V27 AND V34 FLUSH ESCUTCHEON ESCUTCHEON TECHNICAL SPECIFICATIONS: Material: Cold Rolled Steel Optional Materials: Brass Stainless Steel Finishes: Chrome White Custom NOTE: All Nickel Teflon* sprinklers must use stainless steel escutcheons. Stainless steel and brass options are available painted black, white or custom. See current Price List for complete offering. For expansion plate information, please refer to submittal publication 40.84. * Teflon is a registered trademark of Dupont Corporation. JOB OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Date Approved www.victaulic.com viclAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED RE V_B \htauIic 40.88_i FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLER ACCESSORIES FireLock® Escutcheons FOR RECESSED OR FLUSH SPRINKLER INSTALLATION (029/16"/ 2°III65.10 mm 65.10 mm ½/ 15.91 mm 12.70 mm V29 EXTENDED ESCUTCHEON V29 FLUSH ESCUTCHEON @ 73.03 mm P211/16771.37 mm 3.1m lWor OI:'/ WI Adjostment to ~ or ½J19.o5 28.580120.64mm 12.70 mm or 12.70 mm V27 AND V34 RECESSED ESCUTCHEON V27 AND 834 FLUSH ESCUTCHEON * NOTE: THIS ESCUTCHEON CAN READJUSTED TO RECESS ½ OR 3W112.70 OR 19.05 MM www.victauIic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02011 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 40.88_B /tauIicr REV _B Escutcheons FOR RECESSED OR FLUSH SPRINKLER INSTALLATION WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 2/2011 VICTAULIC IS A REGISTERED TRADEMARK OF VIcTAULIc COMPANY. © 2011 VICTAULIC COMPANY. ALL RIGHTS RESERVED, 40.88 6321 REV B A-C_tau-lid 40.88 Bull Moose Tube's" Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVED (;j Af NFPA 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE SIZE (IN) 0.0. (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 1.315 1,097 15.27 1.41 lbs/ft 1.820 - 91 1 1/4 1 660 1.442 991 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2375 2157 627 2641bu/ft 4223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3500 3.260 354 4341bs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft ll.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 r -1-1/4 1.660 1.380 1.00 Z27 lbs/ft -________2.918 51 1-1/2 1.900 1.610 1.00 272 lbs/ft 3602 44 2 2.375 2.067 1.00 366 lbs/ft 5.114 30 2-1/2* 2.875 2.468 1 00 580 lbs/ft 7.875 30 3 3.500 3068 100 758 lbs/ft 10.783 19 4 4.500 4.026 100 10801bs/ft 16.316 19 'Only available in Casa Grande, AZ "Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas Dl Masory OH e,ocenucv 63017 Bu" Moose Tube'sO Eddythread40® ADVANTAGES OF BULL MOOSE TUBES EODVTHREAD 40® is lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. 1 Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E. Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EODYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 100 3.308 4.942 30 *corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVER For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 8824666 salesAPbullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grande, AZ Dallas,D( Masury, OH 63017 5 M NFPA STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the 00 of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Date Approved www.victaulic.com vIcTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_G \4taulicr 10.52_i IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 E-1-1. * II L!h Nomi inchne al Size smm Ho e Diwnele, Dimensions - inches/millimeters Appr x. Weight Each 114 1/2 1146 1 130 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3,4 .-t .- 1 3A 1.28 1.83 1.10 3.87 1 2.56 1.1 20 30.2 32.5 46.5 27.9 1 98.3 65.0 0.50 1- 1 1 3M 1.52 2.18 1.10 I 3.87 2.56 1.2 25 30.2 41 1 38.6 1.42 55.4 1.95 27.9 1.22 98.3 1 4.08 65.0 - 2.56 0.54 1.2 114 x½ 40 15 30.2 36.1 j 49.5 31.0..4 103.6 65.0 0.54 3% 13/16 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 _35.6 49.5 31.0 103.6 L65 0.54 4 1 13A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 1A6 41.7 1.66 58.4 2.19 31.0 1.46 103.6 4.60 65.0 2.56 0.59 1.3 2 x ½ 50 15 30.2 + 42.2 55.6 37.1 116.8 65.0 0.59 34 1 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 L± 13A6 1.91 2.44 1.71 37.1 4.116.8 5.40 65.0 2.56 0+68 1.6 21/2 1h 65 15 30.2 48.5 62.0 43.4 J 137.2 65.0 0.73 3/4 1146 1.89 2.44 1.71 5.40 2.56 1.6 20 9L_.._9 62.0 1 1/ 1 2.13 2.79 1.71 5,40 2.56 1.6 25 30.2 541 1/6 F 1.91 2.44 70,943.4 1.71 4137.2 5.50 65.0 2.56 0.73 1.6 1/2 76.1 mm X s 30.2 48.5 620 43.4 .1 1 ._+ 0.73 3/4 1 3A6 1.89 2.44 1.71 5.50 2.56 1.6 20 &J 1 2 7 4 0.73 1 13A6 4 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 1 54.1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-T STYLE 922 I' Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com vICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 \4taulicr - REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com \JtauIic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 AtauIic vicTAuLic IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2009 vlclAuuc COMPANY. ALL RIGHTS RESERVED. 10.52 Juctile Iron Threaded Fittint II - SMITH.COGPER® INTERNATIONAL Ductile Iron Threaded fittings Specifications I branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP C®LJS Ductile iron castings conform to ASTM A536 - LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B 1.20. Independent lab ver.fication that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temeratnre Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -2C to 100 500 150 - 500 200 480 250 - 460 300 440 420 350 400 400 450 - 380 500 :360 550 - 340 600 - 320 300 650 COUS <~> APPROVED LISTED Fig. 35E3-90° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 - 35E 3006 131 70 140 03 1 35E3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 - 35E3020 1.94 18 36 1.1 2 2.25 10 - 20 1.8 2-1/2 35E 3024 1 2.70 4 8 3.2 Size in Part Number A in B in Packing Weight lb Inner I Master 3/4x1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x112 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 - 60 0.6 1-1/2x3/4 351RE3014006 1.52 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 351RE3014012 1.82 1.88 - 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 36 1.0 - 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 21/2x11/2 35RE3024014 216 251 6 12 22 2-1/2x2 35RE3024020 2.39 2.60 6 1 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number _______ A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F 3006 0.98 80 160 0.3 1 35F3010 1.13 40 80 0.5 1-1/4 - 35F3012 1.29 25 50 40 0.7 1-1/2 35F3014 1.44 20 1.0 2 35F3020 1.69 10 20 1.6 2-1/2 35F3024 1.95 4 8 2.7 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 - 0.5 1 35T 3010 1.50 25 50 0.7 1-1/4 - 35T3012 1.75_ 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 3020 _35T 2.25 6 12 - 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com Size in Part Number A in B in C in Packing _ Weight lb Inner Master 3/4x1/2 35R13006004 1.20 1.20 1.22 60 120 0.4 lx 1/2 35R13010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 50 0.6 0.6 1 x3/4 35R13010006 1.38 1.38 1.45 25 1 x3/4x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 0.7 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 1-1/4x 1/2 35R13012004 1.34 1.34 1.53 20 40 0.8 1-1/4x112x1-1/4 35RT3012004012 1.75 1.53 1.75 25 15 50 30 0.9 0 1-1/4 x3/4 35R13012006 1.45 1.45 1.62 1-1/4x3/4x1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 30 50 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 25 1.0 1-1/4x 1 x 1/2 358T3012010004 1.34 1.26 1.53 0.7 1-1/4x1x314 35RT3012010006 1.45 1.38 1.63 20 40 0.8 - 1-1/4 x1x1 35R13012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35R13014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35RT3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35R13014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 - 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x 1/2 35RT3014012004 1.41 1.34 1.66 16 - 32 0.9 10 11/2x1 1/4x3/4 35RT3014012006 152 145 175 16 32 1-1/2x1-1/4x1 35RT3014012010 765 1.58 1.80 16 32 1.1 11/2x 1-1/4 x 1-1/4 35RT3014012012 1.82 175 1 88 14 28 1.3 1-1/2x 1-114x 1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x 1/2 2x3/4 35RT3020004 1.49 1.49 1.88 10 20 1.5 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7-- 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 1.9 2x1-1/4 35RT3020012 -1.90 1.90 2.10 8 16 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 351RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 2x1-1/2x1 35R13020014006 1.60 1.52 1.97 10 20 1.4 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-114 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 1 35RT3020014014 2.02 1.94 2.16 _8_ 16 1.8 T41I C I COUS A~P.OVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number ____ A in B in C in Packing Weight lb Inner Master 3/4x 1 35B13006010 1.45 1.45 1.37 30 - 60 40 0.6 lx 1-1/4 35BT3010012 1.67 1.67 1.58 20 0.9 1 x 1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-112 35BT3012010014 1.88 1.80 1.82 15 30 1.2.- 1-1/4 x 1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 l-1/4x2 35B13012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 359T3014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 358T3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL" • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Fig. 35CP3 - Straight Coupling with Ribs c®uS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 - 35 70 0.5 1-1/2 35CP3014 2.19 25 50 30 0.7 2 35CP3020 - 2.62 15 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1x1/2 35HB3010004 1.06 180 360 0.2 1x3/4 35H83010006 1.06 180 360 0.1 1-1/4x1 11!2i... 35HB3012010 1.19 90 180 0.2 35HB3014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 75 150 0.3 2 x 1 - 35HB3020010 1.38 40 80 .2L. 2x1-1/4 35HB3020012 1.38 40 80 0.6 2x1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 - 700 0.1 1 - 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 - 1.50 45 90 0.6 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 - 2x1(nothex)35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number _____________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-f4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 9 www.smithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 200 400 - Oi 1 35C3010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 1 70 140 0.4 1-1/2 35C 3014 1.33 50 100 - 0.5 0.8 - 2 35C 3020 1.45 25 50 2-1/2 35C3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Fig. 35X 3- Cross c®uS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 1.50 20 40 0.9 1-1/4 35X3012 -.1.75 12 24 1.4 - 1-1/2 - 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 1 6 12 1 2.8 Fig. 35R13 - Reducing Cross I Size I in I Part Number I I A I i in I B I I in I Packing I Weight I I I lb I I I Inner I Master I 1-1/4x1 35RX3012010 1.67 I 1.58 15 I 30I1.2 I1-1/2 x 1 135RX3014010 1.80 I 1.65 12 I 24 l----- 2x 1 1 35RX3020010 2.02 I 1.73 8 I 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner I Master 3/8 -- 35BC3003 - 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL0 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 AtSTEPS- & 1EE1} STML/TlONSTEPS 1"jiit!:, Insert the appropriate nut driver into a 3/8" or 1/2 portable drill. Insert the SAMMYS0 into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, boll stock. (The 1/2" requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, slop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel _ N?OIGON3RE I Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4' 3/8' 112", or metric all thread rod or bolt stock. (#I4SW red nut driver used with 112" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw L1 TkT Using an SOS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drilO, and insert the #I4SW (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. flPJIiINlilIlAllIIlI1lFliEI SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. o. KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Mm. effective embedment h in. Allowable load Ultimate load Tension lb Shear lb4'5 Tension lb Shear lb45 1/4-20 UNC 1-3/8 1 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensioni configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 25 - Surge Restrainer C® US LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave 9 Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Dimensions Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSRPD Approved C&L us LISTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICEIMANUFACTURING FACILITY • 1375 SAMPSON AVE.. CORONA, CA 92879 • PH: 951,737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200F Fig. 200 Fig. 200S Fin 200 - I'M mline" Adiustable Rand Hannr (Conner R-Line Fin. R17flNF ®TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. / Fig. 200-1 to 200-2 Fig. 200-21/2 to 200-8 Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. ff Fig. 200C 1r. Part No. 200-1/2 Pipe 1/2 Size (15) Rod Size /8-16 ' 31/8 11 (5.0) 200-/4 3/4 (20) /8"-16 31/8° (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /811-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200_11/4 11/4" (32) /8"-16 33/4 (94.0) 2/8" (73.0) 13 (5.9) 200_11/2 11/2' (40) /8-16 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2" (50) /811-16 41/2" (114.3) 3 (76.3) 15 (6.9) 200-2/2 21/2" (65) /8"-16 5/8" (142.9) 41/8' (104.7) 27 (12.3) 200-3 3" (75) /811-16 5/8' (149.1) 4" (101.6) 29 (13.3) 200_3112 31/2" (90) 1 3/8"-16 7/e (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8" (187.3) 5' (127.0) 35 (16.0) 200-5 5" (125) 1/2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. PPI COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61 -G FBC6 SYStEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gl drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 © 2012 Fire Protection Products, Inc. FPPI°, LubeFit'° are registered trademarks of Fire Protection Products, Inc. FGGIBM/CZ, Blaze-Master", FlowGuard Gold° and Corzan5 are registered trademarks of Noveon IP Holdings Corp. Nu LA 0 MADE IN U.S.A. F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FBC5. SYSTEM COMPATiBlE *FBC' System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been 'made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com WW © 2012 Fire Protection Products, Inc. FPPt, LubeRtll are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMastere, FlowGuard Gold" and Corzan' are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. F P P I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. Thread Fit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. -I © 2013 Fire Protection Products, Inc. FPP1, ThreedFit5 are registered trademarks of Fire Protection Products, Inc. LA MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke F.RCVX1 SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. PERMIT REPORT C('City of Carlsbad Print Date: 12/16/2021 Permit No: FPC2017-0073 Job Address: 2016 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-4400 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2130201800 Track #: Applied: 03/16/2017 Valuation: $19,766.75 Lot #: Issued: 04/11/2017 Occupancy Group: Project #: Finaled Close Out: 02/03/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: QUALCOMM CONFERENCE ROOM -FIRE ALARM TI FPContractor: COSCO FIRE PROTECTION INC 1075 W LAMBERT RD BREA, CA 92821-2944 (858) 444-2000 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Tpczon--CO~3 . ......s.cosco 'S..... Fire Protection San Diego Branch Office 4990 Greencraig Lane San Diego, CA 92131 (858) 444-2000 fax: 444-2056 State License No: C-16 & C-10-5 77621 www.coscofire.com MATERIAL SUBMITTAL Date: 3/16/2017 QUALCOMM SAN*PMR*B 2016 PALOMAR AIRPORT ROAD CARLSBAD, CA. 92008 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted By: TD Los Angeles • San Francisco • Orange • Fresno 0 San Diego • Seattle U L Applicant ID No: 257057-001 Service Center No I Expires: 31-MAR-2017 CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: LAKE FOREST, CA Alarm Service Comoanv: 1257057-001 ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 Service Center: 1257057-001 ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 25341 COMMERCENTRE DR LAKE FOREST CA 92630 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN Listing Category BP10307 - I CRZM Monitoring Stations, National Industrial Security S8126-1 UUFX (Signal and Fire Alarm Equipment and Servtces) (Protective Signaling Services) Central Station \ r ***THIS CERTIFICATE EXPIRES ON 31-MAR-2017 / "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" U L 8 [ Applicant ID No: 257057-001 I Service Center No 2 I Expires: 31-MAR-2017 I CERTIFICATE OF COMPLIANCE THIS IS TO CERTIFY that the Alarm Service Company indicated below is included by Underwriters Laboratories Inc. (UL) in its Product Directories as eligible to use the UL Listing Mark in connection with Certificated Alarm Systems. The only evidence of compliance with UL's requirements is the issuance of a UL Certificate for the Alarm System and the Certificate is current under UL's Certificate Verification Service. This Certificate does not apply in any way to the communication channel between the protected property and any facility that monitors signals from the protected property unless the use of a UL listed or Classified Alarm Transport Company is specified on the Certificate. Listed Service From: IRVING, TX (IRVING) Alarm Service Company: (100234-872) ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 8860 N MACARTHUR BLVD IRVING TX 75063-7598 Service Center: (100234-872) ADVANCED PROTECTION INDUSTRIES INC, DBA NATIONAL MONITORING CENTER 8860 N MACARTHUR BLVD IRVING TX 75063-7598 The Alarm Service Company is Listed in the following Certificate Service Categories: File - Vol No. CCN ListingCateqory S8126-3 UUFX [Signal and Fire Alarm Equipment and Services) (Protective Signaling Services)CentraIStation 3 "*THIS CERTIFICATE EXPIRES ON 31-MAR-2017 "LOOK FOR THE UL ALARM SYSTEM CERTIFICATE" SILENT . KNIGHT by Honeywell lntelliKnight®5808 Single Loop Addressable Fire Alarm Control System The convenience of an addressable fire alarm control panel in a cost-effective easy to use package. lntelliKnight Model 5808 is a 127 point class leading single loop addressable fire alarm control/communicator system. 5808 provides you with the revolutionary value and performance of addressable sensing technology combined with exclusive, built-in digital communication, distributed intelligent power, easy to use interface. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Silent Knight. For more information about the lntelliKnight system, or to locate your nearest source, please call 1-800-328-0103. Description The basic 5808 system can be enhanced by adding modules such as 5860 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), and 5496 intelligent power module. 5808 supports SD or 5K protocol devices. 5808 also features a powerful built-in dual line fire communicator that allows for reporting of all system activity to a remote monitoring location. • Features Built-in support for up to 99 SK detectors and 99 SK modules. Built in support for 127 SD devices. Up to 125 zones and 125 output groups. Uses standard wire—no shielded or twisted pair required Built-in digital communicator. Central station reporting by point or by zone Supports Class B (Style 4) and Class A (Style 6 or 7) configuration for SLC. Distributed, intelligent power. Drift compensation. 13 pre-programmed output cadences, (including ANSI- 3.41), and 4 programmable outputs. Notification circuits can be configured as 2 Class A (Style Z) or 4 Class B (Style Y), or auxiliary power for resettable, constant, or door holder power. Built-in annunciator with 80-character LCD display. RS-485 bus provides communication to system accessories. Built-in RS-232 and USB interface for programming via a PC. Upload or download programming, event history, or detector status via remote or direct connection. Improvements in SKSS deliver five times faster upload/downloads. Built-in synchronization for appliances from AMSECO, Gentex®, Faraday, System Sensor®, and Wheelock® One Form C trouble relay rated at 2.5A at 27.4 VDC and two Form C programmable relays rated at 2.5A at 27.4 VDC. (Model 5808, Plex-2 door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions. Integrated dead front panel protects operator from exposure to electrical components. The FACP enclosure features a Plexiglass® viewing window to protect annunciator. Acknowledge function allows operator to keep track of event status. Installation The 5800 can be surface or flush mounted. Compatibility The 5808 signal line circuit (SLC) supports multiple device types of the same protocol: SK SD You cannot mix SD and 5K SLC devices on a FACP. 5496 - .L, øIo45S3Pei,i I Ifl4Sf&OM)Ltjt ILJ r,n:, u,., ., .asnn. Sm,.:. ,tWOWj. 4Z2 nJin c*in,q m,.,mac l43 De.ar , I Specifications Electrical Primary AC: 120 VRMS at 50/60 Hz, 2.75A Total Accessory Load: 6A © 27.4 VDC Notification Power: 6A @ 27.4 VDC, power-limited Standby Current: ( 70 mA Alarm Current: 365 mA) Notification & Auxiliary Circuits: 3A @ 27.4 VDC per circuit, power- limited Battery Charging Capacity: 7.0-35 AH Battery Size: 18 A max. allowed in FACP. Larger capacity batteries can be housed in an RBB accessory cabinet Physical Flush Mount Dimensions: 14.5" W x 24.75' H x 3.5" D (36.8W x 62.9 H x 8.73 D cm) Overall Dimensions: 16" W x 26.4" H x 4.65" D (40.6Wx67 Hx11.8Dcm) Weight: 28 lbs. (12.8 kg) Color: Red Telephone Requirements: FCC Part 15 and Part 68 approved Type of Jack: RJ31X (two required) Approvals NFPA 13, NFPA 15, NFPA 16, NFPA 70, & NFPA 72: Central Station; Remote Signalling; Local Protective Signalling Systems; Auxiliary 5808 Protected Premises Unit; & Water Deluge Releasing Service. Suitable for automatic, manual, waterfiow, sprinkler supervisory (DACT non-coded) signalling services. UL Listed CSFM 7165-0559:0142; MEA 429-92-E Vol. XIV OSHPD (CA) OSP-0065-10 S-BUS Accessories 5860111 Remote Fire Annunciator Features the same 80 character backlit LCD display keypad and firefighter's key switch as the 5808. 5860 is gray and 5860R is red. 5496 Intelligent Power Module A 6 amp notification power expander that provides four additional power-limited notification appliance circuit outputs. 5880 LED/10 Module Features 40 LED outputs, 8 normally open dry contact inputs and one piezo output. 5865-3 and 5865-4 Remote LED Annunciator Features 30 programmable LED (15 red and 15 yellow) outputs and a piezo sounder. The 5865-4 adds a silence and reset switch to the package. 5824 Serial/Parallel Printer Interface Module Provides one parallel and one RS-232 serial port for connecting a printer to 5808. Use to print a real-time log of system events, detector status reports, and event history. 5883 Relay Board Features 10 general purpose Form C relays. Used with 5880 module. Miscellaneous Accessories 5660 Silent Knight Software Suite PC-base software for FACP programming. Upload and view panel account information, event history, and detector status. 5670 Silent Knight Software Suite End-user facility management software allows viewing of detector status and event history via modem or direct connection. Plex-2 Door Dead front cabinet door with clear window to limit access to the FACP. RBB Remote Battery Box Accessory Cabinet. Use if backup batteries are too large to fit into FACP cabinet. Dimensions: 16"W x 10" H x 6" D (406 mm W x 254 mm H x 152 mm D) SK-SCK Seismic Compliance Kit SD and 5K Devices See the specification sheets listed below for a complete listing of the SD and SK devices. 53624 SD Devices data sheet 53623 SK Devices data sheet IntelIiKnight & JumpStart are Registered Trademarks of Silent Knight Flexput is a Trademark of Silent Knight D This document is not intended to be used for installation purposes. We try to SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA 350386 Rev. L © 2013 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0142 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models *5808 *1FP100 Fire Alarm Control Units. Power limited, automatic, manual, local, remote station, central station, waterfiow, water releasing and sprinkler supervisory service. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: 5808, IFP-100 Control Units *01 FP-100BD Motherboard 7628 EOL Resistor 5860/5860R/RA-1000 Annunciator *0lFP100lA IFP-100 User Interface *0586315808 User Interface 5496 Power Module 5824 Serial/Parallel Interface RPS-1000 Power Expander/Supply 5865-3/5965-4 LED Annunciator . 5880 LED 10 Module 5883 Relay Interface Board SD500-ANM Addressable Notification Module SD500-LIM Line Isolation Module 5D505-61B Isolation Base SD-500 SDM Smoke Detector Module RA-100 Remote Annunciator 3158 Reverse Polarity Module 5220 Direct Connect Module *122740 *122723E Enclosures RATING: 120 VAC Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0559:0142 Page 2 of 2 .This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 0 Rev. 10-3-08 ma This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division • 0 SILENT KNIGHT by Honeywell Distributed Power Module you need maximum power In an emergency, Model 5495 The 5495 Distributed Power Module by Silent Knight is the most powerful and cost-effective power supply available today. It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor®,Gentex®, AMSECO®, Wheelock and Faraday - what you need to drive power- hungry components like ADA notification appliances. The 5495's advanced microprocessor design is years ahead of the competition. Its switch mode power supply design is up to 50% more efficient than competitive linear mode power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current systems without the costly investment in new components. For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent Knight today for more information at 1-800-328-0103. S Model 5495 Distributed Power Module The 5495 is a 6 amp notification power expander that provides its own AC power connection, battery charging circuit, and backup battery for use with fire and security controls such as the Silent Knight Model 5208 Fire Control /Communicator. The 5495 is the cost- effective solution for powering notification appliances required by the Americans with Disabilities Act (ADA). The 5495 has built-in ANSI cadence pattern, which can upgrade older control panels that lack cadence capability. Features UL Listed for 6 amps of notification power Power supply's advanced switch mode design reduces damaging heat and manages power up to 50% more efficiently than other systems Dip switches allow for easy reconfiguration 24 VDC filtered output voltage Four power-limited notification outputs; 2 Class A or 4 Class B, or 1 Class A and 2 Class B Additional continuous auxiliary output 3 amps per output circuit 2 inputs; 2 Class B or 2 Class A Ground fault detector/indicator Independent trouble relay AC loss delay option shuts off power to non-essential high-current accessories like magnetic door holders Built-in synchronization for appliances from System Senso,,Gentex®, AMSECO®, Wheelock and Faraday Stand alone operation Lightweight design adds to ease of installation and reduces shipping costs Operates with most polarized, UL Listed notification devices ANSI Cadence pattern output capability built-in Connection to Local Fire Control The 5495 may be connected to a local fire control which utilizes Class A or Class B type notification circuits operating between 9 and 32 VDC. The control panel's notification circuit is connected to one of the inputs on the 5495. The control panel's notification circuit end-of-line resistor is also connected across two terminals on the 5495, which provides supervision between the 5495 and the fire control panel. Polarized audible and/or visual notification devices are then connected to the 5495 signal circuits using the 4.7kc end-of-line resistors provided. Since the 5495 draws very little power from the control, it is possible to connect one 5495 to each notification circuit on the control panel and still provide full supervision of the notification circuits all the way back to the control panel. Model 5495 Distributed Power Module Approvals UL Listed MEA 429-92-E Vol XII CSFM 7300-0559:123 NFPA 72 OSHPD (CA) OSP-0065-10 (see accessories) PN 350395 Rev G © 2015 Honeywell International Inc. -4 Class B (Style Y) (1 Class A & 2 Class B) Amps per output circuit: 3.0 (6.0 amps total) Notification circuit output: Alarm Current (for typical voltages) drawn from main panel's notification appliance circuits. 12 VDC 6.5 mA 24 VDC One input circuit - 15 mA; Both input circuits -30 mA No. of inputs: 2 Input configuration: 2 Class B or 2 Class A Input voltage range: 9 - 32 VDC Battery charging capacity: 35.0 AH Ambient temp.: 32° to 120° F (0° to 49° C) Mechanical Dimensions: 12.25" W x 16" H x 3" D (30.88 cm W x 40.64 cm H x 7.62 D cm) Indicator Lights AC power on: Green Battery trouble: Yellow Ground fault: Yellow Aux trouble: Yellow Output troubles (1-4): Yellow Ordering Information 5495 Distributed Power Module Accessories: SK-SCK Seismic Compliance Kit op Model 5495 Distributed Power Module Model 5495 Block Diagram Signal Circuit Output Signal I Signal I Input Distributed Signal 2 Signal Circuit Output Signal 2 Power Input Module 5495 Signal 3 (Optional) Signal 4 120 VAC Aux. Power Trouble Output Local Fire Control (Alternative to notification circuit trouble.) Supervision The 5495 supervises a variety of functions including: Low AC power . Low battery condition Earth ground fault Auxiliary output power limit condition EOL supervision trouble or power limited condition at an output When a trouble condition occurs, the 5495 creates a trouble condition on the host control signal circuits to which it is connected. the 5495 still maintains the ability to be activated by the host control. In addition, the 5495 provides a Form C trouble relay output as an alternative to using the notification circuit trouble. Electrical Specification AC input: 120 VAC at 2 amps Output: 24 VDC at 6 amps Current: Standby 75 mA Alarm 205 mA Auxiliary power circuit: I Notification circuits: 4 Output configuration: 2 Class A (Style Z) D SILENT This document is not intended to be used for installation purposes. We try to S KNIGHT keep our product information up-to-date and accurate. We cannot cover all IN 1 specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-7161 Phone: (800) 328-0103, Fax: (203) 484-7118.For Technical Support, please call 800-446-6444. www.silentknight.com Assembled In America CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0559:0123 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SILENT KNIGHT SECURITY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models 5395, *5495 and *5499 Distributed Power Module (Indicating Circuit Expander). Unit is power-limited and consists of an enclosure, printed circuit board, terminal boards, end-of-line resistors and two 12VDC, 7Ah rechargeable batteries. The unit provides up to 4 indicating zones and 1 auxiliary output. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Input: 120 VAC, 2A, 60 hz Output: 24 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Unit must be able to provide 24 hour battery back-up as required per code. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as indicating circuit expanders for use with separately listed compatible indicating devices and polarized, 24 VDC, fire alarm control unit. Model 5495 and 5499 can generate a distinctive temporal pattern fire alarm signal as required per NFPA 72, 2002 Edition. If required, models 5395 must be use with fire alarm control unit or indicating signaling devices that can produce the temporal code pattern. Refer to listees Installation Manual for details. NOTE: *Rece 08-17-2006 jw V This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct . operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (SK-Photo (Base included) 0 D SILENT KNIGHT by Honeywell SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors The SK-Photo is a photoelectric smoke detector, the SK-Photo-T is a photoelectric smoke detector with thermal and SK-PhotoR is a photoelectric detector with remote test capability. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight lntelliKnight Fire Alarm Control Panels (FACPs). For more information about the lntelliKnight system, or to locate your nearest source, please call 800-328-0103. n Description SK-Photo and SK-Photo-T are plug-in type smoke sensors that combine a photoelectric sensing chamber with addressable analog communications. Point ID capability allows each detector's address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. SK-Photo and SK-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the SK-Photo-T, dual electronic thermistors add 135°F (57°C) thermal technology to maximize detection. The SK-PhotoR is a remote test capable detector for use with the DNRIDNRW duct smoke detector. (not included) Features Sleek, low-profile design Base included Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the SK-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 3600 visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA1 OOZ) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed FM Approved Specifications Physical Height: 2.0"(5.0 cm) Diameter: 4.1" (10.4 cm) installed in B501 base Electrical Operating Voltage: 15-32 VDC Standby Current: (300 pA@ 24 VDC Maximum Alarm Current:.5 rnA@ 24 VDC max (with LED on) Environmental Operating Temperature SK-Photo: 321 - 120°F (0°C - 49°C) SK-Photo-T: 321 - 100°F (0°C - 38°C) Humidity: 10% —93% non-condensing Other Ratings SK-Photo-T Thermal: Fixed temperature set point 135°F (57°C) Velocity: 0 —4000 fpm (0 —20 m/sec) Installation The SK-Photo and SK-Photo-T plug into a compatible lntelliKnight-series detector base. The SK-PhotoR is a remote test capable detector head included within the DNR (W) duct smoke detector. Compatibility SK-Photo, and SK-Photo-T are compatible with the following detector bases: B21OLP 6" base (included) B501 2 wire base B224RB Relay base 13224131 Isolator base B200SR Sounder base The SK-Photo, SK-Photo-T, and SK- PhotoR are compatible with the following lntelliKnight FACPs: 5820XL 5820XL-EVS 5808 5700 5600 (Rev 2.0 or higher) Model SK-Photo, SK-Photo-T and SK-PhotoR Intelligent Photoelectric Smoke Sensors Engineering Specifications The contractor shall furnish and install where indicated on the plans, Intelligent photoelectric smoke sensors Silent Knight 5K-Photo or SK-Photo-T with thermal. The combination detector head, and twist-lock base, shall be UL listed and compatible with Silent Knight's lntelliKnight fire control panels. The base shall permit direct interchange with SK-Photo or SK-Photo-T. Base shall be the appropriate twist-lock base part number B21OLP (included). The PhotoR is a remote test capable detector for use with DNR(W) duct smoke detectors. (not included). The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SK-Photo shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. Wiring SK-Series Detector Mounting Bases D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all .specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.silentknight.com MADE IN AMERICA FORM# 350118 Rev E © 2013 Honeywell International Inc. fLURE 1. TERMINAL LAyOITh TAMPERPROOF BASE TERM NA C0127-00 fLURE 2. MOUKnKg DETECTOR TO BOX- SNAP ON DECORATIVE RING p4—SCREWS (NOT SUPPLIED) DETECTOR BASE I Th SYSTEM INSTALLATION AND MAINTENANCE INSTRUCTIONS SENSOR -1 3825 Ohio Avenue, St Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 02IOLP Plug-In Detector Base www.systemsensor.com Diameter: 6.1 inches (155 mm) Mounting: 4-inch (102 mm) square box with orwithout plaster ring; Minimum Depth- 1.5 inches (38 mm) 4-inch Octagon Box; Minimum Depth- 1.5inches(38mm) 3'/2-inchOctagonBox; Minimum Depth- 1.5mches(38 mm) Single Gang Box; Minimum Depth- 1.5 inches (38mm) Operating Temperature Range: Refer to applicable sensor Operating Temperature Range using the Base/Sensor Cross Reference Chart at http:\\www.systemsensor.com C BEfORE INSTAWN Please thoroughly read the system wiring and installation manuals, and man- ual System Smoke Detectors Application Guide, which provides detailed in- formation on detector spacing, placement, zoning, and special applications. Copies of these manuals are available from System Sensor or through a Sys- tem Sensor distributor. gENERAl. DESCRIPTION The B210LPisaplugin detector base intended for use ina2-wire intelligent sys- tem, with screw terminals provided for power (+ and-), and remote annuncia- tor connections. Communication takes place over the power (+ and-) lines. BASETERMINALS NO. FUNCTION Power (-), Remote Annunciator (-) Power (+) Remote Annunciator (+) MOUNTINg This detector base mounts directly to 3'/2- and 4-inch octagon boxes, 4-inch square boxes (with or without plaster rings) and single gang boxes. Tomount, remove the decorative ring by turning it in either direction to unhook the snaps, then separate the ring from the base. Install the base on the box using the screws supplied with the junction box and the appropriate mounting slots in the base. Place the decorative ring on the base and rotate it in either direction until it snaps into place (see Figure 2). INSTAUA1lON WIRINg gUIDELINES All wiring must be installed in compliance with all applicable local codes and any special requirements of the authority having jurisdiction, using the proper wire size. The conductors used to connect smoke detectors to control panels and accessory devices should be color-coded to reduce the likelihood of wiring errors. Improper connections can prevent a system from responding properlyinthe eventof afire. For signal wiring (the wiring between interconnected detectors), it is recom- mended that the wire be no smaller than AWG 18. However, the screws and clamping plate in the base can accommodate wire sizes up to AWG 12. The use of twisted pair wiring or shielded cable for the power (+ and-) loop is recommended to minimize the effects of electrical interference. If shielded cable is used, the shield connection to and from the detector must be continuous by using wire nuts, crimping, or soldering, as appropriate for a reliable connection. Make electrical connections by stripping about 3/8inch (10 mm) of insulation from the end of the wire (use strip gauge molded in base), sliding the bare end of the wire under the clamping plate, and tightening the clamping plate screw. Do not loop the wire under the clamping plate. The zone wiring of the detector base should be checked before the detector heads are installed in them. The wiring should be checked for continuity and polarity in the base, and dielectric tests should be performed. The base includes a label for recording the zone, address, and type of detector being installed. This information is important to set the address of the detector head that will later be plugged into the base and to verily the type required BOX (NOT SUPPLIED) for that location. CO 128-00 D250-01-00 1 156-0595-007R fIURE 3. TYPICAL WIRINg DIARAM fOR 2-WIRE LOOP: fIgURE 4*. ENABLINg ThE CAPABILITY: REMOTE CAUTION: DO NOT LOOP WIRE PLASTIC LEVER ANNUNCIATOR UNDER TERMINAL 1 OR 2. SUPERVISION OF CONNECTIONS. BREAK TAB AT DOTTED LINE BY TWISTING TOWARD CENTER OF BASE CO 130-00 ilIllI'C$IIIIIiIIJ_UJL - C0129-00 NOTE: Do NOT use the tamper-resistant capability if the XR2 or XR2B Re- movalToolwill be used. The Tamper Resistant Tab, in the Detector Mounting Bracket, can make the detector tamper-resistantby making it necessary to use a small screwdriveror similar tool to detach the detector from the base. To make the detector tamper-resistant, use needle-nose pliers to break the smaller tab at the scribed line on the tamper resistant tab. Figures 1 and 4A show the location of this tab on the detector mounting bracket. To remove the detector from the base after it has been made tamper resistant, remove the decorative ring by rotating it in either direction and pulling it away from the base. Then, insert a small screwdriver into the notch, as indicated in Figure 4B, and press the plastic lever toward the mounting surface before rotating the detector counterclockwise for removal. REMOTE ANNUNCIATOR, MODEL RA400Z Connect the remote annunciator between terminals 1 and 3 using the spade lug terminal included. The spade lug terminal is connected to the base termi- nal as shown in Figure 5. It is not acceptable for three stripped wires to be under the same wiring termi- nal unless they are separated byawasher or alug like the spade lug supplied with the model RA400Z. See Figure 5for installation. 4B. REMOvINg ThE DETECTOR hEAD fROM ThE BASE- USE SMALL-BLADED SCREWDRIVER TO PUSH rr I C0130-OO fIgURE 5. CONNECTION TO REMOTE ANNUNCIATOR TERMINAL" WIRE WITH SPADE LUG C0116-00 I Please refer to Insert for the Umftatlons of Fire Alarm Systems I ThREE-YEAR MAUlED WARRANTY System Sensor warrants its enclosed smoke detector base to be free from defects in ma- terials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this smoke • detector base. No agent, representative, dealer, or employee of the Company has the au- thority to increase or alter the obligations or limitations of thisWarranty.The Company's obligation of this Warranty shall be limited to the repair or replacement of any part of the smoke detector base which is found to be defective in materials or workmanship under normal use and service during the threeyearperiod commencingwith thedateofmanu- facture. After phoning System Sensor's toll free number 800-SENSOR2 (736-7672) fora Return Authorization number, send defective units postage prepaid to: System Sensor, D250-Ol-OO Repair Department, RA #_, 382 5 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unreasonable use, modifications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss ordamage is caused by the Company's negligence orfauIt. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 156-0595-007R 02008 System Sensor CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0559:0149 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: SILENT KNIGHT 5ECUR1TY1985 Douglas Drive, MN10-212A, Golden Valley, MN 55422 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: Models IDP-PHOTO, lDPPHOTOR*, IDP-PHOTO-T, IDP-ACCLIMATE, 5K-PHOTO, SKPHOTOR*, SK-PHOTO-T and SK-ACCLIMATE photoelectric type smoke detectors. Model IDP-PHOTO-T employs a 1350F supplement integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as photoelectric type smoke detector for use with listee's separately listed compatible fire alarm control units and bases. All models are suitable for open areas and inside duct installations with air velocities between 0-4000 FPM. Models IDP-PHOTO and IDP-PHOTOR are approved for installations inside System sensor duct housing DNR (OSFM Listing No. • 3242-1653:209) and DNRW (OSFM Listing No. 32421653:210)*. Models SK-PHOTO and SK-PHOTOR are approved for installations inside Silent Knight SK-DUCT (OSFM Listing No. 3242-0559:162) and System Sensor DNRW(OSFM Listing No. 32421653:210)* NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires that smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0028:0206 *Rev. 02-01-10 fm * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct S V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR F Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert@ Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features . Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting 4,—.- Syst The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings S1GNALBIG MEA LISTED APPROVED S4011 (chimes, horn strobes, horns) 3023572 approved MEA452-05-E 7125.1653.186 (indoor strobes) 7125.1653:188 (horn strobes, chime strobes) S5512 (strobes) 7135-1653:189 (horns, chimes) SpectrAlert Advance Specifications Architect/Engineer Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuft'° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/RNR or regulated 24 DC/FWR1 Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal) or 16.5 to 33 V (24 V nominal) InputTerminat Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6L x 4.7W x 2.5"D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6L x 4.7W x 1.3"D (142 mm Lx 119 mm x 33 mm D) Wall-MountTnm Ring Dimensions (sold as a 5 pack) (TR-HS) 5.7L x 4.8W x 0.35"D (145 mm L x 122 mm W x 9 mm D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. F, S, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. • UL Current Draw Data uiu Strobe Current iiDraw ziiwiii IlJ.r:rTi7 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB 8-17.5 Volts 16-33 Volts DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMS), 2 -Wire Horn Strobe, Standard Candela (15-115 -Range cd) 8-17.5 Volts 16-33 Volts DC Input 15 15175 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low UL Max-.-Current Draw (mA DC Input 132 154 RMS), 2-Wire Horn Strobe, 16-33 Volts 135 150 177 80 High 185 Candela 90 105 Range (135-185 cd) FWR Input 161 184 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 Switch Volts Position Sound Pattern dB DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 8t Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 tSettings 7, 8, and 9 are not available on 2-wire horn strobes. I SpectrAlert Advance Dimensions T1 C Wall-mount horn strobes SpectrAlert Advance Ordering Information Wall Horn Strobes P2R 2-Wire Horn Strobe, Standard cd, Red P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain P2W 2-Wire Horn Strobe, Standard cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White P2WH-P 2-Wire Horn Strobe, High cd, White, Plain P4R 4-Wire Horn Strobe, Standard cd, Red P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Wall Strobes (cont.) SRH Strobe, High cd, Red SRH-P Strobe, High cd, Red, Plain SRH-SP Strobe, High cd, Red, "FUEGO" SW Strobe, Standard cd, White SW-P Strobe, Standard cd, White, Plain SWH Strobe, High cd, White SWH-P Strobe, High cd, White, Plain Horns HR Horn, Red HW Horn, White Accessories TR-HS Trim Ring, Wall, Red SBBR Indoor Surface Mount Back Box, Red SBBW Indoor Surface Mount Back Box, White Notes: All -P models have a plain housing (no "FIRE' marking on cover) All -SF models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. "STEM Ohio Avenue • St. Charles, IL 60174 02014 system sensor. to, current product information, including the latest version at this data sheet. SENSOR' Phone: 800-SENSOR2 • Fax: 630-377-6495 Prod of specifications subject to Change Without notice, Visit nysternsenoor.com www.systemsensor.com AVDO10201 • 1/14 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (630) 762-5025 Fax (630) 377-7245 Email: Vladimir. Kireyevhoneywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, 134RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..\BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes" can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "Corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ( operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division