Loading...
HomeMy WebLinkAbout2051 PALOMAR AIRPORT RD; 110; FPC2018-0283; PermitPERMIT REPORT Cr'city of Carlsbad CARLSBAD, CA 92011-1462 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0283 Status: Closed - Finaled Applied: 08/27/2018 Issued: 10/02/2018 Finaled Close Out: 02/03/2021 Inspector: Final Inspection: Print Date: 12/16/2021 Job Address: 2051 PALOMAR AIRPORT RD, # 110, Permit Type: FIRE-Construction Commercial Parcel #: 2130503900 Valuation: $511,610.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: INDEX (IDEX) HEALTH & SCIENCE -SPRINKLER TI (16 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ffc~019 --(VS 3 . TfirZ ecc. MATERIAL DATA SUBMITTAL IDEX Health & Science 2051 Palomar Airport Road - Suite 105 Carlsbad, CA 92011 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Reliable F 1 FR56 Sprinkler 20-23 Sprinkler Reliable G556 Sprinkler 24-29 Sprinkler Reliable F156 Sprinkler 30 Hanger Afcon Fig. 300 Ring Hanger 31 Hanger Afcon Fig 655 All Thread Rod 32-33 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 . tfpjohnc©gmail.com DynamThreade Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of 5ch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. S Dyna-Thread's inside diameter is up to 3,6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 401Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40lDyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40lDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. WI. (H20 Filled) Pc Wt/Lift (21') Wt,Uft (24') WI/Lift (25') In; mm In; mm Lbs/Fl; Kg/m Lbs/A; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1 Ys' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 two/Flow control (') died 16100 S. Lathrop Harvey, IL 60426 11350 Norcom Rd. Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: (800) 882-5543 Fax 708-339-1806 Submittal Data Sheet Dyna-Thread . Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "AM". Specifications NPS Nominal I.D. WI. Wt. (1120 fIled) Pcs/ Will (21') WtIUft (24') WIJUft (25' In; inni In; mm Lbs/F!; Kg/rn Lbs/F!; Kg/rn Lift Lbs; Kg tbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1056 1¼' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1½' 1.639 2.290 3,22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February I, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as () <(> () are Dyna Thread and Super 40. XL is manufactured with Exterior galvanized coating. BIT is Listed Approved Listed manufactured with Black lacquer coating. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: 2 S3-4 S tqC0 /Fire & Building / )Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tyco° Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings: 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI 131.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly Installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty Is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and In no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a particular ouroose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. t registered trademark of E. I. du Pont do Nemours and Company or its affiliates. TFPI7IO Page 2of 10 TFP1710 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 DN15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 DN25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44.5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2,25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 DN65 (68,3) (1,22) 0 S S FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW 0.64 Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19.0) (0,18) (25.4) (11,2) 0.81 86200 1.13 0.81 (20,6) (0.29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0156) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0.79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 TFPI7IO Page 3of 10 FIGURE 812 900 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Inches Inches Inches Inches Inches Weight Lbs. Part Number DN (mm) (mm) (mm) (mm) (kg) 314x112 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (302) (16,0) (16,0) (0,15) 1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 0N25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x3/4 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 86213 0N32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-114x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0.35) 1-1/2x3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-1/2x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40 x 32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50 x 20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DNSO x 25 (44,4) (52,3) (50,8) (33,3) (0,72) 2x1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DNSO x 40 (50,8) (55,6) (31,8) (36,6) (0.76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 S TFPI7I0 Page 5of 10 Nominal Pipe Size A Approx. ANSI Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.18 72779 DN15 (28,7) (0,08) 3/4 1.31 0.26 72778 DN20 (33,3) (Oil) 1 1.50 0.44 72755 0N25 (38,1) (0120) 1-1/4 1.75 0.54 72754 DN32 (44,4) (0,24) 1-1/2 1.94 0.71 72753 0N40 (49,3) (0,32) 2 2.25 1.15 72752 DN50 (57,1) (0,52) ___ 2-1/2 2.69 2.29 72758 DN65 (68,3) (19,0)_________ 0 01 S f II_ Al FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 B Approx. A B inches Weight Part inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.33 86340 1.38 0.31 (14,2) (0,15) (35,1) (79) 0.75 0.50 86341 1.63 0.56 (19,0) (0,23) (41,4) (14,0) 0.81 0.85 86230 1.75 0.38 (20,6) (0,38) (44,4) (9,7) 1.06 1.30 86231 2.00 0.56 (26,9) (0,59) (50,8) (14,0) 1.19 1.63 86232 2.19 0.75 (30,2) (0,74) (55,6) (19,0) 1.50 2.63 86233 2.63 1.13 (38,1) (1,19) (66,8) (28,7) 1.56 4.55 86234 3.00 0.75 (39,6) (2,06) (76,2) TFPI7I0 Page 6of 10 0 S Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815' A B C D E F Approx. ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN Lbs. Number (mm) (mm) (mm) (mm) (mm) (mm) (kg) 1-1/2x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 0N40 x 32 x 15 (36,6) (33,3) (42,9) (17.5) 1 (16,0) (28,7) (0,47) 1-1/2 x 1-1/4 x 3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 0N40 x 32 x 20 (38,1) (36.6) (44.5) (19,0) (19.0) (30,1) (0,50) 1-1/2x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 DN40 x 32 x 25 (41.4) (39.7) (46.0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 0N40 x 32 x 50 (55.6) (54.1) (50,8) (36.6) (36.6) (57,1) (0,88) 1-1/2x 1-1/2x 1/2 1.44 144 1.69 0.69 0.69 1.13 1.14 86261 DN40 x 40 x 15 (36,6) (36,6) (42,9) (17.5) (17,5) (28,7) (0.52) 1-112x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19.0) (19,0) (30,1) 1-1/2x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40 x 40 x 25 (41,2) (41,2) (46.0) (22,4) (22,4) (28.7) (0,62) 1-1/2x1-112x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27.0) (27,0) (30,1) 1-1/2x1-112x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 0N40 x 40 x 50 (55,5) (55,5) (50.8) (36,6) (36,6) (31,7) (0.91) 2x1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DN50 x 25 x 50 (57.2) (50.8) (57,2) (38.1) (33.3) (38.1) (0.99) 2x1-1/4x2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 86267 DN50 x 32 x 50 (57.2) (54.1) (57,2) (38.1) (36.6) (38.1) (1.05) 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (38,1) (36,6) (47.8) (19,0) (17.5) (33.3) (0,68) 2 x 1-1/2 x 3/4 1.63 1.50 1.94 0.88 0.75 138 1.61 86269 DN50 x 40 x 20 (41,4) (38,1) (49,3) (22.4) (19.0) (35,0) (0,73) 2x1-1/2x1 1.75 1.63 2.00 1.00 0.88 1.31 1.65 86270 DN50x40x25 (44,5) (41.4) (50.8) (25.4) (22,4) (33.3) (0.75) 2 x 1-1/2 x 1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 DN50 x 40 x 40 (52,4) (49,2) (55,5) (33,3) (30,2) (36.6) (0.92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50 x 40 x 50 (57.1) (55.5) (63,5) (38,1) (36,8) (38.1) (1.07) 2 x 2 x 1/2 1.50 1.50 1.88 0.75 0.75 1.31 1.50 86222 0N50 x 50 x 15 (38,1) (38,1) (47.8) (19,0) (19,0) (33.3) (0,68) 2x2x3/4 1.63 1.63 1.94 0.88 0,88 1.38 1.67 88223 DM50 x 50 x 20 (41.4) (41,4) (49.3) (22,4) (22,4) (35.0) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 DNSO x 50 x 25 (44.5) (44.5) (50.8) (25,4) (25.4) (33.3) (0.86) 2x2x1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47.8) (47.8) (54,1) (28.7) (28.7) (36.6) (0.93) 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55.6) 1 (31,8) (31.8) (38,1) (0.96) 2 x 2 x 2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3.67 86227 DNSO x 50 x 65 (68,8) (66,8) (60.5) (44.5) (47,8) (36.6) (1.66) 2-1/2 x 2 x 3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65x50x20 (44,5) (41,4) (58,7) (15,9) (22,4) (44,5) (1.01) 1 _ TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO 1FTiJ FIGURE 820 FIGURE FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part ON (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Number (kg) (kg) 112 0,88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0110) (5018) (23,9) (0,30) (28,7) (0,08) 1 1,18 033 72824 2.19 0.81 1.08 88276 1.25 0.28 86294 0N25 (30,0) (0,15) (55,6) (20.6) (0,49) (31,7) (0,13) 1-1/4 1.31 0.54 72758 2.50 1.06 1.54 86277 1.38 0.50 86295 0N32 (33,3) (0124) (63,5) (26,9) (0,70) (35,1) (0,23) 1-1/2 1.38 0.68 72822 2.63 1.19 2.03 86278 1.44 0.70 86296 0N40 (35,1) (0,31) (66,8) (30,2) (0,92) (36,6) (0,32) 2 1.50 0.96 72823 3.13 1.63 3.15 86279 1.50 0.90 86297 0N50 (38,1) (0143) (79,5) (41,4) (1,43) (38,1) (0,41) 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 0 S IA _ Lt U FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING 73982 Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - DN15 x 15 (38,1) (0,09) 112 x 1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4 x 3/4 1.50 0.22 72981 - - - - - - - DN20 x 20 (3811) (0110) 3/4 x 3/4 2.00 0.31 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4x1/2 - - - - - - 1.75 0.69 0.38 86772 DN20 x 15 (43,2) (17,5) (017) 1 x1/2 - - - 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25 x 15 (26,9) (0110) (42,9) (12,7) (0,17) 1 x3/4 - - 1.06 0.18 72762 1.75 0,50 0.53 86229 0N25 x 20 (26,9) (0,08) (43,2) (12,7) (0,24) 1-114x1 - 1.19 0.31 72763 - - - - 0N32 x 25 (30,2) (0,14) 1-1/2x1 - - - 1.25 0.53 72757 - - - - DN40 x 25 (31,7) (0124) 1-1/2x1-114 - 1.25 0.35 72764 - - - - DN40 x 32 (31,7) (0110) 2x1 - - 1.38 0.75 72759 - - - - DNSO x 25 (35,1) (0,34) 2 x 1-1/4 1.38 0.69 72761 - - - - DN50 x 32 (35,1) (0131) 2x1-1/2 - - - 1.38 0.62 72775 - - - - DNSO x 40 (35,1) (0,28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 TFPI7I0 Page 9of1O 0 Housing: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating 'Zinc electroplated conforming to ASTM B-633, Type lii Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel-conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPOM green color code. (See Data Sheet TFP1895 for aid in selecting Listing/Approval iniormation proper gasket) General Description S tLIC01Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap S The Figure40-5 Strap is an economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with lull lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as wallas with theapplicab/e standards of the National File Protection Association, in addition to the standards of any otherauthorities having jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershou!dbecontacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing / Approval information. Page 1 of 2 Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity,flgure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner Is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicablestandards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Are Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid brand properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Are Products. No warranty is given for products or components manufactured by companies not affiliated by ownership wlthTyco Are Products orfor products and components which have been subject to misuse, im proper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Are Products' sole option. Tyco Are Products neither assumes, nor authorizes any person to assumeforit,anyotherobllgationlnconnectionwfth the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibleforsprinklersystem designerrorsorinaccurateorincompleteinformation supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCOFIREPRODUCTSWASINFORMEO ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. (B TFPI 720 Pipe Nominal Dimensions Hole Net A B C 0 Size Size Wt. Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 1V4" X 1/20 2.00 1.50 3.50 1.20 1/i 0.84 50.8 38.1 88.9 30.5 30.2 0.4 1/4° x 3/40 2.00 1.50 3.50 1.20 1/I6 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4"X 10 2.31 1.68 3.50 1.20 1/i r, 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X 1/2k 2.12 1.62 3.50 1.32 1/16 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2°X3/4" 2.12 1.62 3.50 1.32 13/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/20 X 1 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2" x 'I? 2.36 1.86 3.74 1.55 13'i6 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2° x 3/40 2.36 1.86 3.74 1.55 13'16 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2°x 10 2.67 2.04 3.74 1.55 13A6 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2 ff K 1/20 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2' X3/4° 2.61 2.11 4.25 0.99 66.3 53.6 108.0 450.2 0.4 2V2° 2.92 2.29 4.25 :45.70.2 1.80±13/16 1.8/i& 1.21 74.2 58.2 108.0 1 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1V4"X V 8 11/2"X 1" 6 2"x 1" 6 2V?x 10 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP1 720 Figure 40.5 Strap S The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:12) General Notes: It is the Designer's responsibility to select products suitable for the Intended service and to ensure IS that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (IH.1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Bulletin 014 Rev. L R hilabl Model Fl FR Series Quick Response Standard Spray cri C 0 Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall 111 Model Fl FR56 Recessed Sprinkler Types Standard Pendent/Fl/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH 'NSF Certified to NSF/ANSI Standard 61 Annex G EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1 475) Upright Pendent Vertical Sidewall Recessed Horizontal Sidewall XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models Fl FR56, Fl FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR56, Fl FR56LL, Horizontal Sidewall 1: / : .. .--. I.. Concealed Pendent Conventional - *'~Uu Recessed PendentiF1iF2 Recessed PendentiFP XLH Recessed Pendent F1/F2 /I L "I ~, ~ XLH Recessed Pendent FP Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest • published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 1] O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL(1) K5.6 Quick 1/2" NPT See See F1FR42 **F1 FR42LL 1) K 4.2 Response (R1/2) 175 PSI 7 PSI 'Temperature 'Finish Table" F1FRXLH Ratings" Table. F1FR28 K2.8 "Low Lead Sprinklers available only with Temperature Rating 200°F/930C Material Data: Frame Deflector Load Screw *pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 GM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. S Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3, 4, 6 RA1425))2))3X4) RA14140X2))3X4) 7/16(10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA14230X4) I RA14134' 3/8(10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA1421(lX4) RA14114 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 J RA14753> cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant S Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number Sp (SIN) Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2"(15mm)" 1 1/2" NPT (R1/2) 5.6 1 80 1 2.25" (57mm) 1 1,5 RA1415 7/16(11mm) 1/2" NPT (R1/2) ]_4.2 60 2.25" (57mm) 1,5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. 4. Vertical Sidewall *DuPont Registered Trademark Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4(102mm) - 12(305mm) Pendent 4" (102mm) - 12" (305mm) S Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(l) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16' (10mm) 1/2" NPT (R1/2) 4.2 60 2.2511 (57mm) RA1413 3/8" (10mm) I 1/2" NPT(Rl/2) 2.8 40 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler 1 Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) us Metric 1/2(15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) 1 1/2" NPT(R1/2) 1 4.2 60 1 2.25" (57mm) RA1410 " Refer to escutcheon data table for approvals & dimensions 10 l/AREDEEE IlJRNcXUAR I--------- HOE lENT I , FACE OF fillWE FACE OF r sl AT MEEMLA) RECESS - l725.WE3 _______________ Ar MXAWM RECESS - J/879.5N,nj _____ /F2ESf101SSXIA AT MWWM RECESS - 3/AT19m,n1 ALWSIMENr FR AT MWLALIM RECESS - J/179S.SS,J 1/27127,,,.,,) I 4 r wu RECESS - 7/8722.2mm) - I/Ar MINIMUM RECESS - I-S/8741.J,m,,) 12 £NIUITANU'X I AT LAFOIMUM RECESS -l/8T28.Um,J AT MLRAAAM RECESS - 1-5/8741.3mm) a 2,/lE 0(4 - tRAUMA Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Fl or F2 I_I 1 X 1/2' REDUCER 2 518 0(4. 166-7-1 HO Il LE IN CEILiNG - Clip CEILiNG 4 FACE OF FIllNG I L - IV FACE CEILiNG I OF 2 -M' DwfhwoAf AT MAXIMUM RECESS - t—l/2738mm3 J AT MINIMUM RECESS I125.4m,n) AT m) MUM RECESS - 9/18729/167".J..] Tl2.7m . MINIMUM RECESS - l725,Am,) .1 1/4' 0(4. (82.6mm) Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) 1/2"(15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2,3 RA1 485)2)(3) 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant S S Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model 0 Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal Orifice Thread Size Nominal K Factor _________________ Sprinkler Height Approval Organizations and Type of Approval Sprinkler Identification Numbers (SIN) US Metric Light Hazard Ordinary O I Hazard ½" (15mm) 1/2" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1435(lX2)(3) " cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant FACE OF F/TONG TO FACE OF CEILING DIMENSION Ft ESCUTCHEON AT MAXIMUM RECESS 1725.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT M4X/MUM RECESS = 3/4779mm] AT MINIMUM RECESS 3/879.5mm] 2 1/4" HOLE 0/A. [57.2mm] I" X 1/2" REDUCER Fl ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mm3 AT MINIMUM RECESS = 2- 1/16752.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8741.3mm] AT MINIMUM RECESS = 2-1/76752.4mm] Horizontal Sidewall ro I l5/l6D(4.)l 4-12 [492mm] 2 27/32" 014. [IO1.6mm-304.8mm] CEILING TO [72.2mm] DEFLECTOR TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS Fl ESCUTCHEON I 3/4T, m] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT RECESSED HSW W/fl OR F2 ESCUTCHEON (I) FM APPROVED FOR 4" - 6" (701.6MM - 752.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½" (15mm) 5.6 80 ½" NPT F1FR 1350F/570C 1350F1570C 100°F1380C Orange 1 RA1414 ½" (15mm) 5.6 80 1 ½" NPT I F1FR 1550F/680C 1350F/570C 100°F/380C Red 1, 4(1), 6 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 175°F1790C 1650F/740C 1000F/380C Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1FR 2000F/930C 1650F174°C 150°F/650C Green 1 RA1414 (11 For VdS only = 155°F/68°C Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model AOl Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor I I Thread Size Model I Temp. Rating Max. A 'Ambient Bulb Color Approvals pp Sprinkler Identification us I Metric Sprinkler I Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/930C 1650FR4°C 150°F/650C Green 1,5 RA1414 *DuPont Registered Trademark 5. 1' x 1/2" REDUCING TEE OR ELBOW I" x 1/2 REDUCING TEE OR ELBOW " 2 5/16" 0/A - CUP CEILING .4-2 5/8" 014. -H HOLE IN CEILING I 1 1/2" MAX. 1 FACE OF FITTING TO FACE OF CEILING DIMENSION 2 5/8" 0/A. 2 5/16" 0/A - CUP - '1 - HOLE IN CEILING 1 1/2 MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION COVER ADJUSTMENT 15/16" 1/2" MAX. COVER PLATE - ASSEMBLY L3 5/16" 0/A. SPRINKLER CONCEALED. 1 /2" ADJUSTMENT 5/16" MAX . ..J 3/4" COVER ADJUSTMENT L 3 COVER PTE— "0IA. ASSEMBLY SPRINKLER CONCEALED, 5/16" ADJUSTMENT one,oz Figure 1 Installation Aid A protective cap is included for use during installation. Important: The F1FR56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model O Sprinkler Wrench. Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models Fl FR56/CCP & Fl FR56LL/CCP Concealed Sprinkler use the ½" orifice, ½" NPT (R1/2), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model COP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (570C), 155°F (680C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (930C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model COP push on cover plate assembly, rated 135°F (57°C) or • 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the F1FR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark 6. Figure 2 gagement. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8(8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RO1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RO1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model Fl FR56 Pendent Sprinkler or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. [7: Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 1 141 1 286 1 225°F (107°C) Blue (I) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for light hazard" only, while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate( Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4X5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate1) Electroless Nickel PTFE(Teflon )*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint()((') Black Paint Off White Off White (2X6) Off White Satin Chrome Chrome Dull Chrome Dull " Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish appliesonto RA1425, RA1414 and RA1475. (1) cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark Bulletin 034 Rev. D ReJ1ab___e@k Model G5-80, Model G5-56, Model G542, Model G5-28 Quick Response Concealed Automatic Sprinkler w CD 2, 0 c) CD S UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4 (19mm) Adjustment Features Cover plate attachment (Plain or Perforated) with 3%" (19mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in Chrome and White as Standard Finish- es. Special Application Finishes are also available. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28 - Light Hazard Occupancies 2. Factory Mutual Research corp. (FM) - Standard Response (See Page 3) G5-56 & G5-28 only. See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. 3. Loss Prevention council (LPcB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies VdS Schadenverhutung GmbH - Standard Response EC-Certificate of conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4' (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. Plain Cover Plate Perforated cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13. FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is property located below the ceiling. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VN IV Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings which have positive pressure in the space above. Cut a 2/8" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe flthng. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER! CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids, Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied ther than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Plain or Perforated Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes(') Standard Finishes Chrome White Paint Special Application Finishes(2) Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. coverplate custom paint is semi-gloss, unless specified otherwise. For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating Classification Sprinkler Cover Max. Ambient Plate Temp. Ordinary 1650F/740c 1350F/570C 100°FI380c Intermediate 212°F/1000C 1650F174°C 150°F/660c S 2. S Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor _______ Thread Approvals pp Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 3/4" (19mm) 17/32' (15mm) 8.0 115 3/4" NPT (R3A) 1 RA3412 G5-56 Non Adjustable 34"(19mm) 1 1/2"(15mm) 1 5.6 80 1 ½' NPT (R½) 1 1,2,3,4,5 1 RA3415 G5-42 I Non Adjustable 3/4" (19mm) /l6" (10mm) 4.2 60 ½" NPT (R½) 1 1 1 RA3413 G5-28 I Non Adjustable 347(19mm) 3/3 (10mm) 1 2.8 40 ½" NPT (R½) 1 1,2 1 RA3411 For VdS Approval, temperature rating sprinkler 1650F/740c and cover plate 135°F/570C only! x 1/2" REDUCING 1" 3/4" REDUCING TEE OR ELBOW I TEE OR ELBOW t(G580 ONLY oil JL oo.Dm,T,J 5" [58.42mm] 014 HOLE IN CEILING CUP ------ J - [19.05mm] MAX COVER ADJUSTMENT \ \ \ \ \ \ 1/4 [6.35mm] MIN TO CEILING J 1 [25 4mm] MAX DROPPED DEFLECTOR TO CEILING 2-1/4" (57.15mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION - [4.96mm] FLAT COVER PLATE ASSEMBLY ." [84.2 1mm] 014. [I S SPRINKLER 0_34FW 16 COVER PLATE: 3/4" [19.05mm] ADJUSTMENT notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS I" x 1/2" REDUCING TEE OR ELBOW ------f ------f ----H---- RELIABLE P/N 6999991900 " X " BRASS NIPPLE (.58.42mm) 014 CUP -_. " (19.05mm) MAX. COI'ER ADJUSThIENT I 1/4" (6.35m MIN. mCLINGJ 7" (25.4mm) MAX. DROPPED DEFLECTOR TO CEILING 2" [66.55mm] HOLE IN CEILING 3-1/16" [77.72mm] MAX, FACE OF FITTING TO FACE OF CEILING DIMENSION 2-1/4" (57.15mm) MAX. FACE OF NIPPLE EX1 TO FACE OF CEILING DIMENSION '—CEILING RAT COR PLATE t8 2im _____ \ (4.96mm) ASSEMBLY SPRINKLER COVER PLATE: 3/4" [19.05mm] ADJUSTMENT Testing has shown that use of a 'nipple extension" will not affect the listing of the sprinkler. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers .1 Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled ® (800) 431-1588 Sales Offices 0 Paper Reliable (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11114 P/N 9999970421 Bulletin 013 Rev. L e Rc ® Models Fl Series Standard Response inble Standard Spray 0 () psi S S Model F156 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F156 Recessed Sprinkler Types Pendent/Fl/F2/FP Horizontal Sidewall Model F142, F1XLH & F128 Sprinkler Types Standard Upright Standard Pendent Model F142, F1XLH & F128 Recessed Sprinkler Types Pendent/F1/F2/FP Approval Organizations Underwriters Laboratories Inc. and certified for Canada (cULus) Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH EC Certificate: 0786-CPD-40237 (RA1314) 0786-CPD-40253 (RA1 325) 0786-CPD-40254 (RA1 375) UL Listing Category Sprinklers, Automatic & Open (VNlV) Product Description The F156, F142, F1XLH & F128 Series Glass Bulb Sprinkler combines the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. Whether installed on exposed piping or in an office ceil- ing, it is functional and attractive. Beautifully versatile is the description for the Reliable Models F156, F142, F1XLH & F128 Series Recessed glass bulb sprinkler. Recessing the F156, F142, F1XLH & F128 Series enhances its already low profile decorative appearance, and facilitates a rapid and perfect installa- tion. The recessed escutcheon of the Models F156, F142, F1XLH & F128 are highly adjustable. The two piece con- struction makes field installation a very easy and rapid task. This also allows ceiling panels to later be removed without shutting down the fire protection system, thus fa- cilitating maintenance of above ceiling services. Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/171j172 Recessed Recessed XLH Upright Horizontal Sidewall Pendent/FP XLH Pendent Pendent F1/F2 XLH Recessed Pendent FP The F156, F142, F1XLH & F128 Series Automatic Sprin- kler utilizes a 5.0 mm frangible glass bulb. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid phase and in the vapor phase. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distribute the discharging water. The F156, F142, F1XLH & F128 Series Sprinkler tem- perature rating is identified by the color of the glass bulb capsule as well as frame color where applicable. Ll Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Pin tie S (XLH Only) Deflector Load Screw Washer Bulb Frame Cup S O13FG'04 Model F142, F1XLH Upright Technical data: Models Discharge Coefficient Response Thread Max. Working Mm. Working Temperature Finish inish Size Pressure Pressure F156 K5.6 1/2" NPT See See F142 F1XLH K4.2 Standard (R1/2) 175 PSI 7PS1 'Temperature "Finish Table" Ratings" Table F128 K2.8 Material Data: Frame Deflector Load Screw Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or or coated with PTFE Adhesive Glass CDA Alloy 510 CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape Model F156, Upright, Pendent & Conventional Sprinklers Model F142, F1XLH & F128 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval Organization Sprinkler Identification Number (SIN) US I Metric Upright I Pendent Standard -Upright (SSU) and nendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 80 12.25" (57mm) 1,2, 3, 4,5 RA 1 325(2X3)(5X6) 1 RA1314(2X36) 7/16" (10mm) 1/2" NPT (R112) 4.2 60 112.25" (57mm) 1 RA132326' I RA13136 3/8 (10mm) 1/2" NPT (R1/2) 2.8 40 j 2.25" (57mm) 1 RA1321(2R8) I RA13116 Conventional-Install in Upright or Pendent Position 15mm (1) I 1/2" NPT (R1/2) I 5.6 1 80 1 57mm I 3, , 5 1 RA13755 Refer to Bulletin 024 for Special Response Sprinklers (F1S5-56) cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM Approved sprinkler. (4) Polyester coated LPCB & VdS approved sprinkler RA-1325, RA1314 & RA-1375. (6) Electroless Nickel PTFE (Teflon)* Plated - UL listed Corrosion Resistant Upright Pendent Convenlional Model F156, F142, F1XLH & F128 Recessed Pendent Sprinklers0 S Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2(15mm) 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) RA13142> 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA13132> 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA13112 Refer to escutcheon data table for approvals & dimensions Electroless Nickel PTFE (Teflon)" Plated - cULus listed Corrosion Resistant S 2 ,/4 hUE 994 — — r -1 E ,'tRtOh08Y — —FACE 10 Ma CSL'00ON AT -, AT MACMUM 890405 J,J79.5,n,J L - - - VAF MANMIM RECESS 3/4V9,) AOJJSTUO/F I I r M/IWM()M RECESS - P )/ATWROMUMRECESS A 4/kR/MUM RECESS ;/8722.2m,,,) - ?-5/874.JmmJ I AT 4449194/k RECESS I AT 988/MUM RECESS - RECESSED PENDENT win OR F2 ESCUTCHEON '5FF/OR/AN WT FM AFP800 MON Ft ESCUICEESM Model F156, F142, F1XLH & F128 Fl or F2 *DuPont Registered Trademark 11 25//OEM. 166./MI,,1— - Sir REDUCER HOLE IN CE/C/NC / ( / FACE OF POUND CUP 5/i/O 5/4. [58.7n3 - CEXING I SO FACE OF CESUNO I DIMENSION AT 4440/MUM RECESS -1-1/2738-1 - AT MINIMUM RECESS - 1725.4,nm) AT MUM RECESS . 9/16714.3,rn,,1 ADJUSTMENT ____ 3 _____________ AT U/MM//U RECESS - [82.0,,,,,] RECESSED PENDENT W/FP ESCUTCHEON UI/MONO FUPRINKLER NOT EtA APPROVED WITH FR ESCUTCHEON Model F156, F142, F1XLH & F128 FP 3. Model F156 Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy OU. S. Patent No. 6,374,920 Sprinkler Type Deflector to Ceiling Distance (Mm. - Max.) Upright 4" (102mm) - 12(305mm) Pendent 4(102mm) - 12" (305mm) Installation Data: Vertical Sidewall Nominal Orifice Thread Size Nominal K Factor Sprinkler Height Approval (1) Organizations Sprinkler Identification us I Metric Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 8.0 2.25" (57mm) 1, 2, 3 RA1385(1X2)(3X4) 11)LPC Approval is pendent only, 57°C through 141°C ratings. 12 cIJLus Listed corrosion resistant (Polyester coated) sprinkler. cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. (4) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed corrosion Resistant Model F156 Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench FACE OF FI77ING TO FACE OF CEILING DIMENSION F) ESCUTCHEON AT MAXIMUM RECESS 7725.4mm] AT MINIMUM RECESS 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4 779mm] AT MINIMUM RECESS = 3/879.5mm] r2 (/4" HOLE 0)4. [5;1.--1 7" x 1/2" REDUCER - I I5/160IA.)I [49.2mm] TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH ROSS. F) ESCUTCHEON AT MAXIMUM RECESS = 1-3/8734.9mm1 AT MINIMUM RECESS = 2- 7/76752.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS 1-5/8741,3mm] AT MINIMUM RECESS = 2-7/76752.4mm] t2ml (7) 4 "-12" -- [701.6mm-304.8mm] 32 DIA CEILING TO - - [72.2mm] DEFLECTOR Fl ESCUTCHEON 3/4779mm] ADJUSTMENT f2 ESCUTCHEON /2772.7mm] ADJUSTMENT RECESSED HSW Will OR 12 ESCUTCHEON (7) FM APPROVED FOR 4" - 8" [107.60M - 752.4MM] CEILING TO DEFLECTOR. Horizontal Sidewall Note: For Recessed HSW Sprinklers use installation wrench GFR2. FM and cULus permits use with Fl or F2 escutcheons for Installation Data:Horizontal Sidewall "Light Hazard" only. Nominal K Factor Sprinkler Height _________________ Approval Organizations Sprinkler Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN) Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63(67mm) 1.2 1 RA13350X2)(384) cULus Listed corrosion resistant (Polyester coated) sprinkler. cULus Listed & FM Approved corrosion resistant for lead, wax and wax over lead. W".) Polyester coated FM approved sprinkler. ) Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant *DuPont Registered Trademark 4. S S S Application Model F156, F142, F1XLH, F128 & Model F156, F142, F1XLH & Fl 28 Recessed sprinklers are used in fixed fire protection systems: Wet, Dry Deluge or Preaction. Care must exercised that the orifice size, temperature rating, deflector style and sprinkler type are in ac- cordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Junsdic- bon Installation. Installation Model F156, F142, F1XLH & F128 Series sprinklers are standard response sprinklers intended for installation as specified in NFPA 13. They must also be installed with the Model D Sprinkler Wrench specifically designed by Reliable for use with these sprinklers. The Model F156, F142, F1XLH & F128 Recessed Sprinklers are to be installed with a maximum recess of 34 inch (19mm). The Model Fl, F2, and FP Escutcheon illustrated are the only recessed escutcheon to be used with the Model F156, F142, F1XLH & F128 Recessed Sprinklers. The use of any other recessed escutcheon Will void all approvals and negate all warranties. When installing Model F156, F142, F1XLH & F128 Recessed Sprinklers use the Model GFR2 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Note: A leak tight ½" NFl (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. Glass bulb sprinklers have orange covers to protect the bulb dur- ing the installation process. REMOVE THIS PROTECTION ONLY AFTER THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED AND, WHEN APPLICABLE, THE ESCUTCHEONS HAVE BEEN INSTALLED. RASCO wrenches are designed to install sprinklers when covers are in place. Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating: - Specify when ordering - Model F156 Pendent Sprinkler Sprinkler Finish Escutcheon Finish (where applicable) Note: When Models F156, F142, F1XLH & F128 Recessed Sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Escutcheon Data (') (1) SIN: RA1335 - cULus and FM permits use with Fl or F2 escutcheons for light hazard only. *DuPont Registered Trademark Maintenance The Model F156, F142, F1XLH & Model F156, F142, F1X- LH & F128 Recessed Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluid. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause im- proper operation or non-operation. Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0C F Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High1> 141 286 225°F(107°C) Blue Extra High(') 182 360 300°F (149°C) Mauve Ultra High (1)(2) 1 260 500 475°F (246°C) Black (II Not available for recessed Sprinklers. (2) cULus listed for SIN RA1325 and RA1314 only. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34,5 bar) Finish') Standard Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome Polyester Coated (67)(9) White Painted Special ApDlfr'tIon Finishes Sprinkler Escutcheon Electroless Nickel PTFE(lèflon®)"3X10) Electroless Nickel PTFE (Tefion®)* Bright Brass2 Bright Brass Black Plated Black Plated Black Paint(3X9) Black Paint Off White 39 Off White Chrome Dull Chrome Dull Lead Plated(3X4)(8) Wax Coated(3X4)(5X8) Wax Over Lead)3)(4)(5X8) Other colors and finishes are available on special order. Consult factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. 200'F (93°C) maximum. UL and ULC listed only. 155°F to 200°F (68°C to 93°C) ratings only. )1)286°F(141°C) sprinklers may be coated for ambient conditions not exceeding 150°F (66°C). (6) cULus listed "corrosion resistant" applies to SIN Number RA1325 (Upright) RA1323 (upright), RA1321(Upright), RA1335 (HS\A, RA1385(VSt and RA1314 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request FM Approved finish as "Polyester Coated" applies to SIN number RA1314, RA1335 & RA1325 in standard black or white. FM Approved finish applies only to SIN number RA1335 & RA1 385. LPCB and vdSApproved finish applies only to RA1325, RA1314 and RA1375. cULus listed Corrosion Resistant applies to SIN RA1325 ,RA1314 ,RA1323, RA1313 ,RA1321, RA1311, RA1385 and RA1335 5. Reliable...For Complete Protection •Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers .. Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Electrical sprinkler alarm switches Identification signs Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by 1llbI Reliable Automatic Sprinkler Co., Inc. Ack Recycled (800) 431-1588 Sales Offices Paper (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 04/15 P/N 9999970299 IMPERIAL MAX REC. LOAD LBS. METRIC PIPE FROD PIPE ROD 1/2 3/8 400 10 3/4 3/8 400 20 10 1 318 1 400 25 10 11/4 3/8 1 400 32 10 11/2 318 400 40 10 2 3/8 400 1 50 10 21/2 3/8 600 65 10 3 3/8 600 80 10 31/2 1 3/8 600 10 ' 3/8 1000 100 10 5 1250 1 125 12 6 1/2 1250 150 12 8 1/2 1250 200 1 12 * Order Part #300m Note: 1/2" Ring Hanger not <FM> approved (B S 300 RING HANGER S <19> C(S)US l thru 4Inch pipe 112 and 314 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H- 17 1 (Type 10), Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 650°F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - I thru 4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON#310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index 02/01 S 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in linch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 ( D i #14 (Item #1 00-black) Sammys 1/4", 318" rod WOOD - Sammys WSII] I riim 1&VITIt1 II lITfl1Th 'tJse #14 Nut Driver (Item #100) Item 4 Model Shk Lgth Shk Din Box Qty Weight 0 Case Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 GST 100 1 1/4 100 5.00 1000 22 GST 200 2 1/4 100 650 1 1000 23 CST 300 3 1/4 1 100 7.50 1000 24 GST 600 6 1/4 1 50 9.00 500 r 4 ____ Model ________ iwr (Item #100) }Mlest Shk Lgth _____ Shk Din UIJFMtem _____ Load. lb. ULlest Load lb. Pipe Size Actual Pullout Box Qty 10 GST.75 3/4 1/4 564#-6 Ply 100 NFPA 11 GST 10 1 1/4 210# - 7/16 OSB 100 670# - 3/4" Ply UL•FM•NFPA 12 GST 20 2 1/4 9404 850# 3/4-2 1/2 17604-Fir 100 UL-NFPA * 27 GST 25-380 21/2 3/8 1500# 4 2113#-Fir 50 UL-FM-NFPA 13 GST 30 3 1/4 14751! 15004 3/4-4 20604-Fir 100 NFPA 403 GST 40 4 1/4 2180# - Fir 50 NFPA 14 GST 60 6 1/4 22304-Fir 50 ei #I4SW (Item #101-red) Sldewlndem& Sammys 1/2" rod q Wood Joist Not less than 2" nominal width (11/2") TJl Joist lTruss Of Consult buss manufacturer for recommended installation point *predrihing may be required for items #27 and #06 Tools available on page 9. S Double Sheetrock Ceiling Minimum 2" imbedment Into base material for NFPA 13 compliance For vertical use. Install in center of lowerface. UL Listings and CAD Drawings are available at www.SammySuperScrewcorn ] Note: Screws must be installed with appropriate nut driver to comply with warranty Prestressed Concrete Page 5 WOOD —Sidewinders a t #14SW (item #1 01-red) Sidewlnders& Sammys 1/2" rod lius]1111Imrllrlyyuuiim1rlTmTa Use #14SW Nut Driver (Item #101) Item # Model I Shk Lgth Shk Dia I Actual Shear/Pullout I Box ' I Weight I (per 100) I Case Qty I 4016 SWC100 1 1/4 I 100 7.50 I 1000 300 SWG200 2 1/4 17254-Fir 100 8.00 1000 !IIIM1k1'11TIfl I m ri.iiilfl 11 rmTim Use #14SW Nut Driver (Item #101) Approvals ltem# Model Shk Lgth Shk Dia UL Test Load lb. UIJFM Pipe Size ActualBox Shear/Pullout Qty Weight (per 100) is swcio 1 1/4 100 6.00 UL•NFPA 19 SWG2O 2 1/4 1250# 3 17254-Fir 100 7.00 UL.NFPA * 26 SWG25-380 1 21/2 1 3/8 15004 4 1 2249# -Fir 50 10.25 - 25 ISWC30 1 3 1 1/4 1 1 150 8.50 Not less than 2" nominal width (1112") up t03 112" pipe; not less than 3" nominal width 4" & 5" pipe FloorJolst r TJI Joist I Truss Consult truss manufacturer for recommended Installation point 5Pre..driiing may be required for item #26. Tools available on page 9. Installation per NFPA 13 Minimum 2 112" from bottom for branch lines. Minimum 3" from bottom for mainlines. Exception: I This requirement shall not apply to 2" or thicker nailing strips resting SHEETROCK -Toggle on top of steel beams. II I 1IIl vE Rod r&vTu1rmm. Be #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight Case Qty (per 100) 71 SST 300 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock #14 (item#100-black) Sammys 1/4", 318" rod 1(11 r&VIff1L mimi Nut Drier (Item #100) 7e#14 I Model Shk Lgth Shk Dia Actual Pullout Pkg Q Weight Case Qty ______(per 100) SST30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock Note: Screws must be installed with appropriate nut driver to comply with warranty