HomeMy WebLinkAbout2525 EL CAMINO REAL; 206; FPC2019-0262; PermitPERMIT REPORT ((7c ity of Carlsbad Print Date: 12/16/2021 Permit No: FPC2019-0262 Job Address: 2525 EL CAMINO REAL, #206, CARLSBAD, CA 92008-1208 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563020900 Track #: Applied: 11/14/2019 Valuation: $207,992.72 Lot #: Issued: 08/13/2020 Occupancy Group: Project #: Finaled Close Out: 02/02/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: SHOE PALACE - FIRE ALARM TI (ADDRESSABLE, 18 DEVICES) Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov Fit ZoIg - O2l I Johnson Controls 3568 Ruffin Road, South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Product Submittal Project: Shoe Palace The Shoppes at Carlsbad 2525 El Camino Real Suite 206 Carlsbad, CA 92008 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.daniels(ãici.com 11/12/2019 REV.#: 0 PROJECT Johnson Controls 3568 Ruffin Road, South Johnson V San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4009-9601 Nac Repeater 7300-0026:0375 1 4098-9714 Smoke Sensor 7272-0026:0218 1 4098-9792 Detector Base 7300-0026:0217 1 4098-9755 Duct Detector 3240-0026:0241 1 2098-9806 Remote Test Switch 7300-0026:0150 2 4090-9010 Relay 1AM 7300-0026:0311 8 49V0-APPLC Strobe 7125-0026:0373 4 49S V-APPLC Speaker Strobe 7125-0026:0384 Business Information 11/12/2019 REV.#: 0 PROJECT Simplex UL, ULC, CSFM Listed; -too FM, NYC Fire Dept Approved* .11011 ne TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender 4009 IDNAC Repeaters provide enhanced power delivery to TrueAlert/TrueAlert ES addressable notification appliances controlled by IDNAC SLCs: Output voltage in alarm is maintained by an efficient switching regulator at 29 VDC during both AC input and battery backup conditions allowing strobes to operate at lower current With lower current strobes and regulated output voltage, wiring distance can be extended 2 to 3 times that of conventional notification, appliance loading can be increased, or smaller wire gauge can be used, all resulting in installation savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions 4009 IDNAC Repeaters receive an IDNAC SLC input and provide a repeated 3 A SLC output to extend SLC distance and power: Appliance control and address limit remains with the host IDNAC control panel. Repeater status is communicated to the control panel for system diagnostics and also locally indicated Repeater output extends supervisory capacity by up to 139 additional unit loads or 3 A Input SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B output with internal connections for up to four (4) T-tapped output branches (Class A output requires 4009-9814 Class A Adapter) Operation requires one IDNAC SLC address; Repeaters can be connected as one in series, or up to five (5) in parallel in AC power input is 120 VAC or 220-240 VAC, 50/60 Hz, auto-select An on-board battery charger is provided with low AC battery disconnect selectable per Repeater (required for ULC listed applications) Operation is compatible with TrueAlert ES and TrueAlert addressable notification appliances and accessories Available with platinum or red cabinet Listed to UL 864 and ULC S527 Multiple wiring options are available: Wiring options include Class B multiple branch (up to 4) output, Class A loop extension, and Class A riser to Class B branches or a Class A loop output When the Repeater is part of a Class A loop from the IDNAC SLC source panel, up to twice the distance for the loop is available; (Class A loop repeating requires 4009-9814 Class A Adapter) This product has been approved byte California Stale Fire Marshal (CSFM pursuant to Section 13144.1 01 the California Health and Safely Code. See CSFM Using 7165 0026:0378 for allowable values andlor cceiddces concerning material presented in this document IOYC Fee Dept COA 46151. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Wings and approvals under Sftpulee Time RcderCa are the properly of Tyco Fire Protection Products. Additional listings may be applicable; contact your local Sknplen product supplier for the latest status. Ustings and approvals under Simplex Time Recorder Co, are the properly of lyre Fire Protection Product '-_5uIi. Extended , distance and current Repeated IDNAC SLC 4009 IDNAC Repeater Simplex Fire Alarm Control Panel with IDNAC SLC (4100ES shown for reference) IDNAC SIC 4009 IDNAC Repeater Extends Distance and Current of IDNAC SLC I 1ui*i(Iii7iTIIJ7ilj Class A Adapter 4009-9814: Required when extending a Class A loop or to provide a Class A local loop SLC output Operation provides short circuit isolation between input and output terminals for improved IDNAC SLC survivability Built-in battery Charger Power supply charges up to 12.7 Ah batteries for in cabinet mounting and up to 25 Ah batteries with model 4009-9801 external battery cabinet Available auxiliary output: in A 200 mA, 29 VDC constant auxiliary output is available; operation is maintained during battery backup S4009-0004-5 6/2015 irnrrrrrnrn Repeating IDNAC SLCs. Simplex fire alarm control panels with IDNAC SLC outputs provide individual address and control of TrueAlert and TrueAlert ES addressable notification appliances. When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC, use of 4009 IDNAC Repeaters extends the IDNAC SLC with an additional 3 A of SLC current and up to 139 unit loads of additional supervisory capacity. With IDNAC SLCs, a constant 29 VDC source voltage is maintained in alarm, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. I I4fs4 1IT1 Three wiring configurations are available to provide a variety of system solutions: Class B branch extension, Class A loop extension, and Class A riser to Class B branch extension or Class A loop output. 111*1.41 F1W771I11TiJ Class B branch input wiring allows T-tapped connections to up to five (5) parallel connected 4009 IDNAC Repeaters. Each Repeater has on-board output terminal connections for up to four (4) output branch circuits, and additional branch circuits can be externally T-tapped as required. (Refer to diagram on page 3 for additional details.) Class A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be doubled. The Repeater communicates and repeats bi-directionally allowing Class A loop operation to be maintained in the event of an open circuit. This wiring connection requires use of the 4009-9814 Class A adapter. (Refer to diagram on page 4 for additional details.) Class A Riser to Class B Branches or Class A Loops. For applications requiring a combination of wiring types, a Class A riser can drive up to five (5) 4009 IDNAC Repeaters with each Repeater capable of driving either single or multiple Class B branch output(s) or a Class A loop output. In this wiring application, the Repeater does not repeat in the Class A riser loop, it is connected as an appliance with Class A in/out wiring. To create a Class A loop output, the Repeater must be equipped with a 4009-9814 Class A Adapter. (Refer to diagram on page 5 for additional details.) Product Selection Model* Cabinet Color Description [4009-96011BA) Platinum 4009 IDNAC Repeater with cabinet; provides a single 3 A IDNAC SLC output, 200 mA auxiliary 4009-9602(BA) Red power output, and battery charger; 120/240 VAC, 50/60 Hz input, auto-select * Add suffix BA to select 4009 IDNAC Repeaters assembled in the USA. Aftermarket Accessories (installed on-site, select per system requirements) Model I Description 4009-9814 Class A Adapter Module, mounts on repeater controller board; required for Class A output 2975-9813 Platinum semi-flush box trim 1 /16 (37 mm) wide, four corners and trim pieces for top, bottom, and sides; (will 2975-9812 I Red semi-flush box trim need to be cut to fit 4009 IDNAC Repeater cabinet) External Accessories (select per system requirements) Model I Description I Comments 4905-9929 1 Remote TrueAlert Communications Isolator I Refer to data sheet S4905-0001 for details 4009-9801 External Battery Cabinet for 25 Ah batteries 16 %" W x 13 '/2" H x 5%" D (413 mm x 343 mm x 146 mm); refer to data sheet S2081-0006 for details Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation) Model Description Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires 4009-9801 External Battery Cabinet 2081-9274 10 Ah Battery, 12 VDC 1 2081-9287 F25 Ah Battery, 12 VDC 2081-9288 112.7 Ah Battery, 12 VDC fi S4009-0004-5 6/2015 4009 IDNAC Repeaters (5 maximum) IDNAC SLC input Class B IDNAC SIC Class B wiring can be T-tapped Class B Branch Extensions IDNAC SLC output I> Class B IDNAC SIC Class B IDNAC SIC 11 Simplex Fire Alarm Control Panel with IDNAC SIC (4IOOES shown for reference) Wirnig Notes I Up to five (5)4009 IDNAC Repeaters can be wired in parallel as shown on this diagram. IDNAC SIC comn'unications can be repeated only once between the source and the addressable appliance. The 4009 IDNAC Repeater extends distance and current of the input IDNAC SIC; it requires one address and consumes four (4) unit loads. Class B IDNAC SIC FRA Class B IDNAC SIC [W?ring Reference, Class B Input with Class B Branch Circuit Outputs -. Each 4009 IDNAC Repeater has duplicate output teminals rated for two wires each, allowing up to four (4) Class B branch circuit T-taps to be made in the cabinet; additional T-taps may be made in external wiring junction cabinets or boxes ISE -L(~ ETW~( f-07- PINK k- ~Rll Class B IDNAC SIC Branch Circuits 3 S4009-0004-5 6/2015 Wiring Reference, ClassA Loop Extension Class A IDNAC SLC Loop with 4009 IDNAC Repeater Extending Loop Range and Power 4009 IDNAC Repeater Requires optional 4009-9814 Class A Adapter Module set for Loop mode 1- Class A loop secondary direction - - - - - flr [ (3fl_ 101119 - Class A loop primary direction - I I I I I I 7-7—E ,,, --- J PINK Fine ping © Class A loop secondary direction Simplex Fire Alarm Control Panel with IDNAC SLC; lequies optional Dual Class A IDNAC Isolator (DCAl), refer to individual panel documentation for details (4IOOES with EPS shown for reference) Notes: Only one 4009 IDNAC Repeater can be wired in a Class A loop. (IDNAC SLC communications can be repeated only once between the source and the addressable appliance) The 4009 IDNAC Repeater extends distance and current of the Class A IDNAC SLC loop; it requires one address and consumes four (4) unit loads. Under normal operating conditions (no open circuit wiring), appliances I through 4 are powered by the Panel Power Supply and appliances 5 through 9 are powered from the 4009 IDNAC Repealer - 4- Under open circuit conditions, an open circuit in the panel side of the primary path will result in the Panel Power Supply powering appliances 5 through 9 and the 4009 IDNAC Repeater will receive IDNAC SLC input from the return path and then power appliances I through 4, or as many as remain connected. S4009-0004-5 612015 16-1/4 (413 10-29/32(277 [iring Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs Simplex Fire Alarm Control Panel with IDNAC SLC; requires optional Dual Class A IDNAC Isolator (DCAI), refer to individual panel documentation for details (4I00ES with EPS shown for reference) Requires optional 4009-9814 Class A Adapter Module set for Branch Mode to create a local Class loop circuit output Class A Loop Extension IDNAC SLC input Class Loop 4-i 4009 IDNAC Repeaters Class B Branch Extension --- L------- IDNAC SLC shown as a Class A Riser with each IDNAC Repeater wired inlout (not T-tapped); IN only t (2) are shown, maximum is five (5) Wiring detail reference (repeaters - } are wired same as appliances) 4009 IDNAC Repeater Mounting and Module Placement Reference L_ Cabinet depth (105 mm) Door (16nml)thk 0 \ \ (343 mm) Eoned cabinet dimension for - semi-lush mount 1 (4 mm). Knockouts for screw 1-3tr(35 mm) wlh or nail mounting holes semi-lush trim 12' (305 mm) ~B~attery ~in dotted line) no conduit entry s area, 12.7 Ali maximum I ! 0 / Optional Semi-Flush Trim K -,. Shaded Area is Non-power Iimted - I-WIW we (30 mm). 3 (9.5mm) thk WI surface reforence for semi-lush mount 5 S4009-0004-5 6/2015 4009 IDNAC Repeater Specifications Input Ratings Voltage Range 120 VAC, 50/60 Hz, or 220/230/240 VAC, 50/60 Hz, +10%, -15%, auto-select Input Ratings 120 VAC Current 2.5A 220/230/240 VAC Current 1.25 A Panel IDNAC Appliances Auxiliary Load 70 mA 0.8 mA each Output current (voltage is from battery) Standby Currents 24 VDC Requirements ___________________________________ for Battery Calculations 4.5 A maximum with 3 A IDNAC SLC load 1.37 x output current Alarm Currents 96 mA and 200 mAAuxiliary output load (actual (voltage converter is on alarm current depends on connected and when in Alarm) activated appliances and devices) 17 VDC minimum IDNAC Input Ratings I address, 4 unit loads Output Ratings IDNAC SLC Output 3 A maximum @ 29 VDC for Special Application appliances Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances Each repeater uses four unit loads on the EPS it receives power from and supports up to 139 additional unit loads. Most appliances are I unit load; Multi-Tone appliances are 2 unit loads; Repeaters and Isolators are 4 unit loads. Refer to individual appliance IDNAC Repeater Loading and SLC and device specifications for unit load requirements and rated SLC loading Address Usage specifications. Each repeater uses one IDNAC SLC device address - the IDNAC Repeater does not increase the IDNAC channel device address capacity. Refer to the Host IDNAC SLC specifications for the device address capacity specifications on the IDNAC channel. Current 200 mA maximum Auxiliary Output Voltage 29 VDC nominal with AC present or when Repeater is on battery standby and in Alarm 24 VDC nominal when on battery standby and not in Alarm IDNAC SLC Wiring Specifications (refer to installation instructions for more information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with "T-Taps"_ for _class _B_wiring 10,000 ft (3048 m Maximum wire length to any appliance 4000 ft (1219 m) Wiring Connections Terminal blocks for 18 to 12 AWG Repeater Status Indicators Green AC Power LED On with AC present, off during brownout or no AC condition Red Communications LED (COMM) Blinks when Repeater is communicating with the host control panel 4 LEDs provide up to 16 different trouble status indications; an on-board trouble scroll Yellow System Status LEDs button allows review should multiple troubles occur 4009-9814 Class A Adapter Module Option (required for Class A loop extension or for Class A output) 3 A maximum @ 29 VDC for Special Application appliances IDNAC SLC Output Voltage Two connections, Port A and Port B, function varies by application (loop extension or local loop), Port A and Port B are isolated from each other Status LEDs Two yellow trouble LED indicators, one per Port Environmental and Technical Publications Reference Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range Up to 93% RH at 90° F (32° C) Installation 4009 IDNAC Repeater 579-1019 Instructions Class A Adaoter Module 579-1080 TYCO, S1MPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strict ly prohibited Tyco Fire Protection Products• Westminster, MA •01441-0001 USA S4009-0004-5 6/2015 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: RATING: INSTALLATION MARKING: APPROVAL: 7300-0026:0375 Page 1 of 1 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com Models 4009-9601 4009-9601 BA, 4009-9602 and 4009-9602 BA IDNAC repeaters. Model 4009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. 120V/240V In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model number, electrical rating and UL label. Listed as an accessory for use with listee's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. 04-23-13 gt . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Simplex UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* I11Ii(4-1 TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simple)& products: 4007ES, 4010, 40IOES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-5529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:2l7 for allowable values and/or conditions concerning material presented in this document. Acceptec for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings ant approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. TrueAlarm Analog Sensing TrueAlarm Analog Sensors - Photoelectric and Heat; Standard Bases and Accessories 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. S4098-0019-23 8/2017 TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Fii i1.] LS]1rT1 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) ALARM 93 Simplex Ocrrintinn TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. liviounting rceiererlue - - Electrical Box Requirements: (boxes are by others) Without r gra in the box: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep 4" octagonal 0r4" square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference- 6 c 1-1/2" (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 2098-9737 Supervised Relay 4098-9822 Relay (mounts (mounts in base electrical box or in base electrical box) remotely) FR.Ia~ySi,e -1I2" X (3.75 in 3)(64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32~~r (1 in3 )(60.4 mm X 31.8 mm X 8.6 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. ii 6-3/8" (162 mm) 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and 4" square flush box 4-7/8" (124 mm) 15/16" TI (24 mm) U TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 S4098-0019-23 8/2017 TI 2-3/8' (60 mm) TrueAlarm Sensors Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. I UL & ULC I FM Spacing, Either Fixed 135° F1190° F' 60ftx60ft 20ftx20 fit (6.1 m) for fixed (57.2°C! 88° C) (18.3 m) temperature only; RTI = Quick 50ftx50ft(15.2 m) for fixed 155° F 40 ft x 40 ft temperature with either (68° C) (12.2 m) rate-of-rise selection; IRTI = Ultra Fast Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. The 4098-9734 sensor provides an additional 190° F (88° C) set point. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. Refer to specflc panels for availability. 'Note: 190° F (88° C) ratings apply only to the 4098-9734 sensor Smoke Sensors: Photoelectric technology sensing 3600 smoke entry for optimum response 0 Built-in insect screens I4098-9714 PhntnIcrtri Sne TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. fki 4-7/8° (124 mm) I "N LED status indicator 2-1/8° (54 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 and 4098-9734 Heat nnr TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. 4098-9733 Heat Sensor with Base LED status in 1111111 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. VTTi IF1ITFT1 :li Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. S4098-0019-23 8/2017 TrueAlarm Analog Sensing Product Selection Chart TrueAlarm.Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model* Color Description Compatibility Mounting Requirements 49-8-9"9 White Standard Sensor Base No options 4" octagonal 0r4" square box, 1-1/2" mm. depth; or single gang box, 2" 4098-9776 Black mm. depth 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or 2098-9808 Remote Alarm Indicator or 4" octagonal or 4" square box 4098-9789 IND White Unsupervised Relay 4098-9822 Unsupervised Relay Note: Box depth requirements 4098-9775 Black depend on total wire count and wire size, refer to accessories 4-Wire Sensor Supervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9791"" White Base with connections for LED list below for reference. Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible 2-Wire Sensor Supervised Relay 4098-9860 Supervised Remote Relay with the 2120 CDT 2098-9808 Remote Alarm Indicator or 4098_9780** White Base with connections for LED Indicator or Unsupervised Relay 4098-9822 Unsupervised Relay lrueAlarm Sensors Model* I Description 4098-9714 IND White Photoelectric Smoke Sensor 4098-9774 Black 4098-9733 White Heat Sensor 4098-9734 White I Hiah Temoerature Heat Sensor TrueAlarm Sensor/Base Accessories Compatibility Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Mounting Requirements Refer to base requirements Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base For use with 4098-9791 base Remote Mounting requires 4" octagonal or electrical box 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal box, 2- Supervised Relay, mounts remote or in base 4098-9860 electrical box For use with 4098-9780 base 1/8" deep with 1-1/2" extension ring 2098-9808 Remote Red LED Alarm Indicator on single gang Bases 4098-9789, 4098-9791, and 4098- Single gang box, 1-1/2" minimum depth stainless steel plate 9780 4098-9822 Unsupervised Relay, tracks base LED status; Bases 4098-9789, 4098-9791, and 4098- 4" octagonal box. 2-1/8" deep with 1-1/2" Note: Mounts only in base electrical box 9780 extension ring Required for surface or semi-flush mounted 4" 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, square box and for surface mounted 4098-9791, and 4098-9780 4" octagonal box * Note: Model numbers ending in IND are assembled in India. General Operating Specifications Communications and Sensor Supervisory Power lDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32" to 100" F (0" to 38° C) with 4098-9733 Heat Sensor Operating Temperature with 4098-9714 Smoke Sensor Range With 4098-9734 Heat Sensor 32" to 122" F (0° to 50" C) 15" to 122" F (-9" to 50" C) 32° to 150" F (0" to 66" C) Storage Temperature Range 0" F to 140" F (-18" C to 60" C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/mm (0-1220 rn/mm) Housing Color I Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 iA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power I Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 118-32 VDC (nominal 24 VDC) Supervisory Current I Supplied from communications Alarm Current 113 mA from separate 24 VDC supply SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). U.Simplex Westminster, MA • 01441-0001 USA S4098-0019-23 8/2017 www.simplex-fire.com 0 2017 Johnson Controls. All rights reserved All specfications and other information shown were current as of document revision dale and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0217 Page 1 of 1 CATEGORY: 7300--FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098*9775, *.9776 *..9777 -9780,-9780E, -9789, -9789E, 9789TSP, -9789TTP, -9791, -9791E, -9791TSP, 9791TTP,-9792, -9792E, -9792T5P, 9792T1P, -9793, -9793E, -9793TSP, -97931TP,-9796, -9796TSP, -97961TP; G5A4098-9780, -9792, -9793, and -9796 smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Models 4098-9775, -9776, -9777, -9780,-9780E, -9789, -9789E, 9789T5P, -9789TTP, -9791, -9791E, -9791T5P, 979111P,-9792, -9792E, -9792T5P, 9792TTP, -9793, -9793E, -9793T5P, -9793TTP; GSA4098-9780, -9792 and -9793 are intended for use with: Models 4098-9714 and G5A4098-9714 photoelectric smoke detectors (CSFM Listing No. 7272-0026:0218); Model 4098-9717 ionization smoke detector (CSFM Listing No. 7271-0026:0231); and Models 4098-9733, G5A4098-9733, 4098-9734 and GSA4098-9734 heat detectors (CSFM Listing No. 7270-0026:0216). Models 4098-9796, -9796T5P, -9796TTP, GSA4098-9796 are only intended for use with Models 4098-9754 or G5A4098-9754 photoelectric smoke detector (CSFM Listing No.7272-0026:0218). These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 2002 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. Refer to listee's Installation Instruction Manual for details. *Rev. 02-08-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0026:0218 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9714, -9774, -9714T5P, -9714TTP, -9754 -9754TSP, -9754TTP; G5A4098-9714, and -9754 analog photoelectric type smoke detectors. Models 4098-9754, -9779, -9754T5P, -9754TTP; G5A4098-9754 analog photoelectric type smoke detectors employ an integral supplemental heat sensor (135°F fixed temperature and 120°F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with listee's separately listed compatible fire alarm control units. Units are intended for use with smoke detector bases Models 4098-9789, -9789TSP, -9789TTP, -9791, -9791T5P, -9775, -9776, -9777, -9791TTP, -9792, -9792T5P, 9792TTP, -9793, 9793T5P, -9793TTP; 05A4098-9792, and -9793 (CSFM Listing No. 7300-0026:0217); *4098....9794 -9794T5P,-9794TTP (CSFM Listing No. 7300-0026:0500). Models 4098-9714, -9714T5P and -971411P are listed for use with Models 4098-9750-9751 -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:0220) and Models 4098-9755, -9755T5P and -975511P duct detector units (CSFM Listing No. 3240-0026:0241). Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. *Rev 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division £Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control 17-M IM Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetTM or MAPNET He, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNetIMAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: . TilL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Duct Sensor Housing, Front and Bottom View 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station irnrrrri Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. Trr.F1l ill iii.] g5j SN IT1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5155,468; 5,173,683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; 0383,407; 0388,352; 0392,573; 4,796,025. S4098-0030-5 3/2007 klTiiiii1i.]g.IJ .xi iIYL7II7i7iJ Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) MR. rrinnq TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. ITT Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. IFireAlarm1Control 1l1Tfl IFeature14 Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control .C_.. rsT rs1r' ._........ tor ON, Orr, or overriuc I liii.] &fl ii FflI Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4020, 4100, 4100U, and 4120. Also 2120 CDT if configured either IDNet or MAPNET II communications (no relay output) for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 Relay output is for up to 15 total 4098-9843 end-of-line resistor harness; includes one 4098-9843 relay Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, 4098-9755 Test Station with keyswitch and red LED status indicator 4098-9756 3" H x 2" W x 2" D (turning switch to "TEST" initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 40989756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; (1 m) of device being connect up to 15 wiring is 18 AWG (0.82 mm2 ) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kf, 1/2 W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 12098-9799 1 2" (51 mm) longer than duct width S4098-0030-5 3/2007 IBM r ji -11IN41:41:4 IN I NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 11-3/8" (289 mm).- FExhaust tube access hole 1 4098-9714 Smoke sensor, mounted in special interface base (supplied) Metal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole 6-3/4" (171 mm) amp1ing tube access hole Yellow LED, relay control trouble indicator (4098-9756 only) nsensor ofduc screws Mount as shown (preferred) or with electronics area located to Lthasketea sensor areal the LEFT or UP ONLY 3-3/8" (86 mm) — (21 mm) 13/16" Sampling tube, ordered Test ports (2) provided and for aerosol injection] [parately per duct width for measuring airflow Exhaust tube (supplied) Duct wall End View with Duct and Tubes 118" Round duct outline' Duct 1...48" Square duct outline1 [(minimum diameter) J (minimum width) J j It s S Sampling tub: keyed for proper hole alignment I with holes facing into airflow (template is I provided for proper tube installation) I 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA72 (38 mm) 1-3/16" (30 mm) 3 S4098-0030-5 3/2007 I Ijt 12] ]iI1ITTh (:] ]iI.(i Exhaust Sensor Damper OK _.Return Exhaust •LZIII 'J Air Do not locate sensor here Return air damper Fresh Supply air Air Filter " Sensor Do not locate bank OK sensor here Bend or other obstruction E111T Return ai" 9 minimum widths 6 Duct inlet ,/ 6 Duct widths minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. LSpecu!ications General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black base with clear cover Remote Status/Alarm LED 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation IDNet or MAPNET II communications, auto-select, one address per housing; Data Communications provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 15 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894)10 kQ, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 15 mA @ 24 VDC, up to 15 maximum per re 7 A at 0.35 PF @28 VDC & 120 VAC Relay Contacts 250jA@5VDC control output Location Distance 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72 7)co, Simplex, the Simplex logo, TrueAlarm, IDNet, and MAPNETII are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). ®SuiPIex Tyco Safety Products Westrninster• Westminster, MA • 0 144 1-0001 • USA S4098-0030-5 3/2007 www.tycosafetyproducts-usa-wm.com © 2007 Tyco Safety Products Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 701 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9755, *40989755TSp *40989755TTp 4098-9756, *40989756TSp *4098..9756TTp 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 -4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexlo0 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division £LSim pIEX UL, ULC, CSFM Listed; FM Approved* I1i 114-1 Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 I1/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 l'i*- iIit1i1 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Model Description (4090-9öi) 8 A Relay IAM Optional Trim Plates and Adapter Model Description 4090-9801 I For semi-flush I Trim plate, galvanized I mounted box I steel, with LED viewing I For surface I window; includes 4090-9802 mounted box mounting screws 4090-9813 Adapter plate to fit (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4Ya"Hx4"Wx1 %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 18 A Relay lAM Mounting Information 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate I © © I © © - —Add supplied label t" lima I W WIN IAvERnssaENT•I cover on-site if controlling IAvnssepir.it .l 4-9/16" 120 or 240 VAC 4-5/16" (116 mm) (109mm) Light pipe for LED viewing © •© © © — 4-9/16" (116 mm) No -5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. S.SiMPIEX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4090-0015-1 11/2014 www.simplex-flre.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current at ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *40909010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5S!mplEx TrueAlert ES Addressable Notification Appliances UL, ULC, CSFM Listed; FM Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Approved* Description Ceiling Mount Addressable Visible (VIO) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC Signaling Line Circuit (SLC). V/O notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process. Features Individually addressed Visible Only (VIO) notification appliances Multi-candela LED strobe available in low (15, 30 75 and 110 cd) and high (110, 135 and 185 cd) range candela models. Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators. Advanced addressable notification controlled bylDNACSLCs. IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current Electrical test point access by removing the cover Strobe intensity can be programmed from the control panel or the device Wiring supervision to each appliance allows T-tapped connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID, custom label, type, and candela setting Magnet test diagnostics assist checkout and testing of appliances and wiring Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Synchronized strobe operation on its IDNAC channel. LED Indicator and Magnet Test feature: Indicator LED indicates magnet test acknowledgment, 3 digit IDNAC address, and candela rating Indicator LED can be configured to blink every polling cycle to indicate appliance supervision When the controller is in diagnostic mode, the magnet test pulses the Indicator LED to indicate appliance address and can be set to also briefly flash the strobe LEDs Mechanical design features Rugged, high impact, flame retardant thermoplastic housing in red and white colors Various covers and lettering options available - Red with white letters or white with red letters Covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts on 4" square or single gang USA electrical boxes. Adapter plate required for mounting on single gang electrical boxes. Optional wire guards Weatherproof back boxes are required for surface mounting. Figure 1: Indoor Ceiling Mount Strobe Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. TrueAlert ES Diagnostics Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Magnet Test In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (ISIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. *Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. AC49VOC-0001 Rev. 12 3/2019 Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Installation Reference Address dip switch Set device address before fixing cover in place. Candela flag setting -.. Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set the flag to the desired candela rating. Appliance with cover (front) Mount to4"X4"XI-1/2" electrical box using 8-32 screws , Note: ceiling mount only Wiring terminals for strobe connections accept #12-18 AWG wires Appliance (rear) Use slotted screwdriver here to remove cover IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When class B wiring is used, wiring can be T-tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1: ceiling Mount Addressable Visual Only V/O Appliances Model* Lens color Description Installation Instructions 49v0-AppLC-BA Clear 49voH-ApPLc 49VoH-APPLc-BA VO appliance only. Select cover separately. 579-1227 49voH-APPLcA Amber 49V0H-APPLCB Blue 49v0H-APPLc6 Green 579-1280 49V0H-APPLcR Red Table 2: Surface/WP back boxes Model Color Description Installation instructions 49WPBB-VOcR Red Surface/WP back box in red 579-1270 49WPBB-vocvv White Surface/WP back box in white Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. Page 2 Ac49VOC-0001 Rev. 12 3/2019 Simpkx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Table 3: Adapter plates Model Description Installation Instructions - NO Ceiling Mount Adapter Plate. Required for 49V0-APCS mounting on a single gang electrical box. 5791227 Table 4: VIO Covers (Required when ordering APPLC models) Model* Color Wording 49V0C-CRALT 49voC-cRBF Red ALERT FEU /FIRE 49voC-CRFEu FEU 49V0C-CRF FIRE 49V0C-CRS 49V0C-CRBAA 1-J(/ALERT 49V0C-CRBCF */FlRE 49V0C-CRBAF '-/FlRE 49V0C-CK Black Blank 49V0C-CWALT White - ALERT 49V0C-CWBF FEU/FIRE 49V0C-CWFEU 49V0C-CWF ç ------ FEU FIRE 49V0C-CWBAA ,iW(/ALERT */FlRE 49V0C-CWBCF 49V0C-CWBAF - j.-/FIRE Table 5: Wire Guards Model Description 49WG-VOCR VO Ceiling Mount Red Wire Guard 49WGBB-VOCR VO Ceiling Mount Wire Guard Back Box Note: * (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6: Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Appliance Voltage Voltage lDesign Reference 4100ES with EPS+or EPS Power Supply S4100-0100 4009 rDNAc Repeater 540090004 .IDNAC SLC 29VDC 23VDC 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 (regulated) (with 6 VDC drop) 4100ES Constant Supervision and Signal Cards Page 3 AC49VOC-0001 Rev. 12 3/2019 SimpIEx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 TrueAlert ES V/O LEGACY Compatibility Reference Table 7: Compatibility Reference Compatible Controller Data Sheet Reference lController Output Available Strobe Intensity Appliance Voltage Minimum 4100ES or 4100U with 54100-0031 TrueAlert Power Supply S4100-0037 IrueAlert Addressable SLC 15, 30, 75, and 110 cd 17 voc 4009 TIPS, Remote TruRert 17 VDC Power Supply* S4009-0003 TrueAlert Addressable Controller (40091) Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 7 VDC to 31 VDC, Special Application Candela Setting 15 c 30cd 75 c 110 c 17 VDC RMS Current Ratings, with horn on continuousat high setting, 73 mA 114 mA 210 mA 269 mA use when connected to TrueAlertAddressable SLCs per above * For connection to legacy fire panel models Simplex 4009T and 4100/TPS. High candela (49V0H) appliances are not compatible with Simplex models 40091 and TPS, see the fire panel compatibility charts. Ceiling Mount yb Specifications Table 8: Specifications Specification Rating Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two Connections wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC. lDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Table 9: Percentage of rated light output at room temperature Angle On-Axis Vertical, Below Axis HorizontaL Left/Right of Axis 0o ~450 ASO 900 UL required output 100% 45% 25% 45% 25% Typical output 327% 1134% 183% 1129% 47% Table 10: Appliance Specifications © 2019 Johnson controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. Simplex, and the product names listed in this material are marks and/or registered marks, unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). AC49VOC-0001 Rev. 12 3/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7125-0026:0373 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimpIex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Model 49AVTrue Alert ES addressable horn/strobes with suffixes WRF, WRF-BA, WJF, WNF-BA, *WRS WRS-BA, WNS-BA, *WRQ, WRQ-BA and APPLW. Model 49AVTrue Alert ES addressable horn/strobe covers with suffixes WRFIRE,WNFlRE, WRS,W\NS, WRALT, WNALT, WRFEU, WNFEU, WRBLNG, and WWBLNG. Model 49VOTrue Alert ES addressable strobes with suffixes WRF, WRF-BA, WNF, WtNF-BA, *wRS WRS-BA, *5 WNS-BA, *\p WRA-BA, *\A \MNA-BA, *\fQ *WRQ ,WRQ-BA, and *\/Q Model 49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, NWFIRE, WRS, \PWSIS, WRALT, \MNALT, WRFEU, WNFEU, WRBLNG, and WNBLNG. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 17-31 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a wall mount horn/strobe or strobe for indoor use only. Models require the use of the 4009-9401 TrueAlert NAC extender (CSFM Listing No. 7300-0026:214) or 4100-5120, -5121, -5122 True Alert Power Supples*or 4100-5311, -5313, -5325, 53-27 Extended Power Supplies (CSFM Listing No. 7165-0026:251) *0r4010..9601 -9602, -9603, -9604, -9606, 9701, -9702, 9722 Control Units (CSFM No. 7165-0026:369) or 4007-9201, -9202 Control Units (CSFM No. 7165-0026:378). Refer to listee's Installation Instruction Manual for details. *Rev 09-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5SimpIEx TrueAlert Addressable Notification Appliances UL, ULC Listed; FM Approved Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Introduction Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from the Simplex Fire Alarm Control Unit IDNAC Signaling Line Circuit (SLC). Audio is supplied from a separate compatible Simplex Fire Alarm Control Unit audio NAC. Wiring supervision is electronically monitored allowing audio and IDNAC wiring to be T-tapped for Class B wiring, reducing wiring costs and wiring distances. Installation on standard 4 inch square 2 1/8 inch deep USA electrical boxes for flush installations (provided by others) or surface/WP backboxes (order below) for surface or WP installations. Appliances are available in 400 -4000 Hz and 200- 10000 Hz high fidelity models. Separate appliance and cover selection greatly simplifies the ordering and installation process. Model numbers ending in -BA are assembled in the USA. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-0001. Figure 1: ceiling Mount Addressable SpeakerNisible Notification Appliance Ceiling Mount Addressable Speaker Product Selection Table 1: ceiling Mount Addressable Speaker SN Appliances Model Description Installation Instructions l9Sv-APP SN appliance only. Select cover and surface/WP box (if 579-1203 49SV-APPLC-BA required) separately. Table 2: High Fidelity Appliances Model Description Installation instructions High Fidelity SN appliance 49HFV-APPLC only. Select cover and 49HFV-APPLC-BA surface/WP box (if required) i5791203 separately. Table 3: High Candela Appliances Model Description Installation instructions High Candela SN appliance 49SVH-APPLC-BA only. Select cover and 9SVH-APPL weatherproof box (if required) 579-1203 separately. Table 4: High Fidelity High Candela Appliances Description instructions i.High Fidelity High Candela 49HFVH-APPLC SN Appliance Only. Select 49HFVH-APPLC-BA cover and surface/WP box (if required) separately. High Fidelity High Candela SN 49HH-APLCA-BA Appliance with amber colored 579-1203 lens. Select cover and surface/ WP box (if required) separately. High Fidelity High Candela S/ 49HR'H-APLCB-BA V Appliance with blue colored Hens. Select cover and surface/ WP box (if required) separately. Table 5: SN Covers (Required when ordering APPLC models) SKU Color Wording 49SVC-CRALT Red ALERT 49SVC-CWALT White 495VC-CRBA 49SVC.CWBA Red 479SVC-CRBC .T'ife Red .j/FlRE '' /FIRE ALARM 49SVC-CWBC White 49SVC-CRBF Red FEU/FIRE FEU 49SVC-CWBF 49SVC SVC 49-CWFEU White Red - .... White 49SVC-CRFIRE Red HIRE 495 VC-C WFI RE White 49SVC-CRS Red Simplex logo only 49SVC-CWS White 149SVC-CK - Black INO logo or lettering * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under simplex Time Recorder co. S49SVC-0001 Rev. 7 10/2018 Simplex Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Weatherproof Product Selection Table 6: Weatherproof Ceiling Mount Addressable SN Appliances SKU Description iinstallation instructions 495vH-ApPLC-0 SN Appliance Only. Select cover and surface/WP 49SvH-APPLC-Co (Canada only) 579-1241 box separately Table 7: SN Covers (Required when ordering APPLC-O models) SKU Color !Wording 49SVC-CRALT-0 1 Red ALERT 49SVC-CWALT-0 White 49SVC-CRBA-0 'Red j/FlRE 49SVC-CRBC-0 Red */FlRE ALARM 49SVC-CWBC-0 White - 49SVC-CRBF-O Red E U/Fl RE 49SVC-CWBF-0 TWhite 49SVC-CRFEU-0 Red EU 49SVC-CWFEU-0 White 49SVC-CRFIRE-0 Red 495VC-CWFIRE-O White -IRE 49SVC-CRS-0 I Red Simplex logo only 49SVC-CWS-0 ]White 49SVC-CK-0 jBlack Table 8: Surface/WP Back Boxes SKU Color Description Installation instructions 49WPBB-SVCR Red Surface/WP back box in Red 5791240 49WPBB-SVCW jVvhite Surface/WP back box in White Table 9: Wire Guards and Wire Guard Back Boxes SKU Description 49WGBB-SVCR-0 49wG-svwCR Wire Guard Back Box, Ceiling, Red, WP Wire Guard, Ceiling, Red Ceiling Mount SN Specifications Table 10: Appliance General Specifications Specification Rating Dimensions . 8 1/8" H x 71/8"W x 3" D (206mm x 180mm x 76mm) Environmental 132° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections 'Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out l,wiring. Use unshielded Twisted Pair (UTP) for IDNAC and audio wiring. Table 11: Speaker Audio Specifications Specification Rating Input Voltage i,25 or 70,7 Vrms Power Taps 11/4,1/2, 1, and 2W l400 to Frequency Response 4000 Hz (SN, SNH), 200 to 10000 Hz (H/F, General Signaling = 125 to 12 kHz Table 12: Speaker Output Ratings Wattage Tap Model ¼W SN H/F 1/2 W SN H/F 1 SN H/F 2W SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 179 176 83 80 86* 84 89* 87* Anechoic Chamber Test, per ULC-5541 (dBA)* 179 178 183 82 86* 85* 89* 88* Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Testing) lAttenuation Angle _.___]Attenuation Angle -3 dB 70° -6 dB 180° Page 2 S49SVC-0001 Rev. 7 10/2018 Simplex Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Table 13: Percentage of rated light A I ng e On-Axis !00 45° Vertical, Below Axis 90° Horizontal, Left/Right of Axis 451 900 UL required output 100% 45% 25% 45% 25% Typical output 327% - 134% 83% 129% l°'° Table 14: IDNAC SLC Specifications Specification Rating Typical Operating Voltage Range 123 VDC to 30 VDC, Special Application Appliance voltage design reference f23vDC (with 6VDC drop) SupervisoryRequirements 1 unit load (=0.8mA control unit current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max127SNappliancesperIDNACchannel Maximum of 127 addresses per SLC, 139 unit loads. See device and IDNAC SLC Loading 1compatible Fire Control unit Installation Instructions for circuit current load limits. UTP, unshielded twisted pair recommended IDNAC SLC Wiring Specifications (refer to control unit installation Maximum wire length allowed with 'T-Taps" for Class B wiring per SLC = instructions for more information) 10,000 _(3048m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Table 15: Current consumption** Candela Setting 15 c 0cd 75 c 110 Cd 135cd - 185 c 49SV and 49HF 59 mA 182 mA 145 mA 193 mA IN/A N/A models 495VH and 49HFVH ................-....—.-- ------- —....-...—...-j--.—.--...------ N/A N/A -.-.---.-..-...-...-...-.-....- N/A 259 mA 1281 mA 325 mA models Weatherproof SV IN/A appliances_______ N/A 320 mA 360 mA N/A 400 mA ** Measured at 23VuC on IDNAC Addressable SLC Speakers are for connection to compatible fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. Table 16: Equipment Compatibility References Compatible Equipment Data Sheet Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 4009 IDNAC Repeater S4009-0004 4T Flex 35 and 50 Watt Amplifiers 4100ES100Watt Amplifiers S4100-0034 I 4100ES Constant Supervision and Signal Cards Page 3 S49SVC-0001 Rev. 7 10/2018 simplex Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Ceiling Mount SN Installation Reference Appliance with cover (front) Appliance (rear) Mount to 4"X 4" X 2-1/8" Magnet test location electrical box using 8-32 I / cD2o 0 indicated by area that __-,. screws is not textured Note: Ceiling mount only id 00%00%G0000 0100 loot 0 00000 00 000 00 0 ::::a °ä%%%%%% \ II -- 1f1J -r11 -'-4i II 000000000000000000000•00 Appliance test points, I /1 %%°ggg:g audio circuit power taps, " 0!0 FM and address dip switch : %%%%%°00 %%%W80° 0 0 00000 00 000 0000000000 0 0000 \ 00000o00000 Set audio circuit power taps and \ ,' OO•.°0000O%0%%OO device address before fixing \ 008 © © cover in place. - - - = Wiring terminals for speaker Candela flag setting = : : : and strobe connections Set flag to FACP to control . accept 2 #12-18 AWG wires candela rating from an FACP - - - - - providing IDNAC notification. - - -. - To set candela manually, set the flag to the desired : " A candela rating. Use slotted screwdriver MCP here to remove cover. Figure 2: Installation reference © 2018 johnson controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). S49SV-0001 Rev. 7 10/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models: 49SV-APPLC,49HFV-APPLC,49SV-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,49SV-CWF,49HFV-CWF49SVH-CW F and 49HFVH-CWS True Aert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49svAppLw0 *49SVAPPLW0BA, *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com Contractor's License Detail for License # 986047 JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2021 This license is current and active. All information below should be reviewed. dO - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Contractors Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of QualifyLi Individual - - This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/20180 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC313943 Effective Date: 10/01/2018 Expire Date: 10/01/2020 Workers' Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses. 10/11/2019 REV.#: 0 PROJECT #: 480- Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com 10/11/2019 REV.#: 0 PROJECT #: 480-