Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 214; FPC2017-0201; PermitCARLSBAD, CA 92008-1208 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check 4*: Plan Check U: Print Date: 12/16/2021 Job Address: 2525 EL CAMINO REAL, #214, Permit Type: FIRE-Construction Commercial Parcel #: 1563020900 Valuation: $388,870.11 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2017-0201 Status: Closed - Finaled Applied: 07/20/2017 Issued: 08/10/2017 Finaled Close Out: 02/02/2021 Inspector: Final Inspection: PERMIT REPORT Cr'city of Carlsbad Project Title: Description: AMERICAN EAGLE OUTFITTERS -SPRINKLER TI 7-100 HEADS (96 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ALEXIS CASSIDY 1341 DISTRIBUTION WAY, 4* STE 14 1341 DISTRIBUTION WAY, U STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov f?cloil-oozoi 01TAW FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 17515 AMERICAN EAGLE OUTFITTERS 2525 El Camino Real Carlsbad, CA 92008 FPC20I 7-0201 2525 EL CAMINO REAL UNIT2I4 p. PILE COpy V3801 and V3802 FireLock® V38, K5.6 Models V3801, V3802 Adjustable Concealed Standard Spray Standard and Quick Response Approvals/Listings: c®use" L _PC B LISTED 0832 104-la/02 See Victaulic Publication 1001 for more details. Product Description: This concealed, designer style sprinkler allows up to 1/2713 mm adjustment to accommodate concealment needs. The 'standard' design provides a consistent hemispherical spray pattern. The separate two-piece mounting cup/cover plate allows easy installation and testing prior to ceiling installation. It also permits removal of suspended ceiling panels without system shutdown. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. Coverage: For coverage area and sprinkler placement, refer to NFPA 13 or applicable standards. 4tauIcr 40.50 Technical Specifications: Models: V3801, V3802 Style: Adjustable concealed, ordinary hazard, light hazard Nominal Orifice Size: 1/2/13 mm K-Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: 1/2/15 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa Temperature Rating: See chart on page 3. 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 100. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 40.50 2558 Rev. 0 Updated 07/2014 © 2014 victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Material Specifications: Accessories: Deflector: Bronze per UNS C22000 Installation Wrench: Cover Plate: Fusible solder El Concealed: V38-4 or V38-5 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: El Standard: 5,0 mm 11 Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Stainless steel per UNS S30100 Seal: Teflon2 tape Frame: Die cast brass 65-30 Pins: Stainless steel per UNS S30400 Cup: Cold rolled steel, zinc chrome plated Cover/Escutcheon: Brass per UNS C26000 Lodgement Spring: Stainless steel per UNS S30200 Protective Cap: Polyethylene Sprinkler Finishes: El Plain Brass (only) Cover Finishes: El Chrome Plated El White Painted3 El Flat Black Painted3 LI Custom Painted3 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 2 \,l'(taUIiC victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Approval/Listings: Approvals/Listings Model V3801 V3802 Orifice Size (inches) 1/2" 1/2" Orifice Size (mm) 13 13 Nominal K Factor Imperial 5.6 5.6 Nominal K Factor SI.4 8.1 8.1 Response Standard 5mm bulb Quick4 3mm bulb Deflector Type Concealed Pendent Concealed Pendent Adjustment Approved Temperature Ratings F°/C° V3801 V3802 135°F/570C 1351F/571C cULus 155°F/68°C 1551F/681C 1750F/79°C 175°F/79°C 2001F/931C 2000F/930C 1550F/68°C4 FM5 NONE 175°F/79°C4 200°F/93°C4 1350F/570C 135°F/570C NYC/MEA5 #62-99-E 1550F/680C 1551F/680C 1750F/791C 175°F/790C 2000F/931C 2000F/930C 135°F/57°C 135°F/570C CSFM5 #7690-0531:112 155°F/68°C 155°F/68°C 1750F/790C 1750F/791C 2000F/930C 2001F/931C 1550F/68C Sprinkler/1 38F/59C Cover 155F/68°C Sprinkler/1 380F/59°C Cover LPCB 175F/79C Sprinkler/1 65°F/74C Cover 1750F/79°C Sprinkler/i 650F/74°C Cover 200°F/930C Sprinkler/165°F/740C Cover 200F/93°C Sprinkler/] 65F/74C Cover 135°F/570C 1351F/571C 155°F/68°C 1550F/680C VNIIPO . 1751F/790C 1751F/790C 200°F/930C 200°F/930C 2861F/1410C 2860F/1410C CCCf ZSTDY NONE 155°F/68°C For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Recognized by FM as standard response only. Note: Listings and Approvals as of printing. All are approved open. 40.50 2558 Rev. 0 updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 A—C—ta—ulicr 2/51 mm W/13 mm 1-1 11— Maximum Extension victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Dimensions: Models V3801, V3802 (drawings not to scale) 2/68 mm Max. Hole E2 in. Hole m 2%f6"/59 mm II II Typical Ceiling Tile Finished Surface Minimum Extension Distribution Patterns: Models V3801, V3802 K5.6 standard concealed pendent distribution patterns - trajectory TftE - * - \44 .. 'S - 4 4 • --,-\-i\I4-- ! 4 -- \ \44 10,.. 3.0 m 8' 2.4 m 6' 1.8 m 4' 1.2 m 2' 0.6 m 0 2' 4' 6' 8' 10' 12' 14' 0.6 m 1.2 m 1.8 m 2.4 m 3.0 m 3.7 m 4.3 m 7ps1 __. 15p51 30 psi 48 kPa 103 kPa 207 kPa NOTES 1 Data shown is approximate and can vary due to differences in installation 2 These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock automatic sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. 40.50 2558 Rev. 0 Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 4 -11, victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 Ratings: All glass bulbs are rated for temperatures from -670F!-550C to those shown in table below. Sprinkler Sprinkler - V3801, V3802 Cover - V38 Temperature - °F/°C Temperature - OFIOC Nominal Maximum Ambient Nominal Maximum Ambient Temperature Victaulic Part Temperature Temperature Victaulic Part Temperature Temperature Classification Identification Rating Allowed Glass Bulb Color Identification Rating Allowed Ordinary A 135°F/570C 100°F/38°C Orange A6 1358 100 57 57 Ordinary C 155°F/68°C 100°F/38°C Red D 7 165 150 74 65 Intermediate E 175°F/790C 150°F1650C Yellow Intermediate F 200°F193°C 150°F/651C Green High J 286°F/141°C 225°F/107°C Blue Extra High 8 K 360°F/1 82°C 300°F/149°C Purple - M Open - No Bulb 6 A For use with Standard or Quick Response Concealed Sprinkler 135°F/57°C or 155°F/68°C. D For use with Standard or Quick Response Concealed Sprinkler 175FI79°C or 200°F1930C. 8 138F/59°C per LPCB Note: Custom Finish - Customer to provide paint specification, allow 4- 6 weeks for samples. Available Wrenches: Sprinkler Type Recessed Concealed Pendent - V3801 V3802 V38-4 or V38-5 40.50 2558 Rev. 0 Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 ___________ victaulic.com I Sprinkler I FireLock® I K5.6, V38 I Publication 40.50 A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. IN I* Installation Note Reference should always be made to the I-lOU Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in PDF format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and Zero-Flex are registered trademarks of Victaulic Company. 40.50 2558 Rev. 0 updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 J''ctauIic' FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response I V _'O ii V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 4tauIicf 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: C®US P ® S 11 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /41719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 © 2014 victaulic Company. All rights reserved. 1 X. Aic—taulic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS 051000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS 065100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated White painted3 LII Black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LI VC-250 155, 200, 286 SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 A-c-ta-ulicr victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: APPROVALS/LISTINGS Model _____________ _____________ V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F"/C° 135°F/57°C 135°F/57°C 155"F/68"C 155°F/68°C 135°F/57°C 135"F/57°C 135°F/57°C 135"F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68"C 155°F/68"C cULus 200"F/93°C 200°F/93°C 175°F/79"C 175°F/79"C 175°F/79°C 175°F/79"C 286"F/141"C 286°F/141°C 200°F/93"C 200°F/93"C 200"F/93°C 360°F/182°C 360°F/182"C 286"F/141°C 286°F/141"C 286°F/141°C 135°F/57°C 135"F/57°C 155°F/68°C 155"F/68°C 135"F/57°C 135°F/57°C 135"F/57"C 135°F/57°C FM 175°F/79°C 175"F/79"C 155"F/68°C 155°F/68"C 155"F/68°C 155"F/68°C 200°F/93"C 200"F/93°C 175"F/79"C 175°F/79°C 175"F/79"C 175°F/79°C 286°F/141"C 286°F/141°C 200°F/93°C 200°F/93°C 200"F/93°C 200°F/93"C 360°F/182"C 360°F/182"C 86°F/141"C 286"F/141°C 2"F/141°C 135"F/57"C 135°F/57°C 135°F/57"C 135°F/57"C 135°F/57°C 155"F/68°C 155°F/68°C 155"F/68°C 155°F/68"C 155°F/68°C 135°F/57°C NYC/MEA 62-99-E 175°F/79°C 175"F/79"C 175°F/79"C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93"C 2007/93°C 200°F/93°C 200"F/93"C 200°F/93°C 175°F/79°C 286°F/141°C 286"F/141°C 286°F/141"C 286°F/141°C 286"F/141°C 200°F/93°C 360°F/182°C 360°F/182"C 135°F/57"C 135°F/57"C 155°F/68°C 155°F/68°C 135"F/57°C 135"F/57°C 135°F/57"C 135°F/57°C 175"F/79"C 175°F/79"C 155°F/68°C 155"F/68°C 155°F/68°C 155°F/68°C CSFM 7690-0531:112 200°F/93"C 200"F/93°C 175°F/79"C 175°F/79°C 175"F/79°C 175"F/79"C 286°F/141°C 286"F/141"C 200°F/93°C 200"F/93"C 200°F/93°C 200°F/93"C 360°F/182°C 360"F/182"C 286°F/141"C 286°F/141°C 286"F/141"C 135"F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175"F/79"C 286°F/141°C 2007/93"C 135°F/57°C 135°F/57"C 135"F/57°C 135°F/57°C 155°F/68°C 155"F/68"C 135°F/57°C 155°F/68°C 155"F/68"C 135"F/57°C VNIIPO 175°F/79°C 175°F/79°C 155"F/68"C 175°F/79°C 175"F/79°C 155°F/68°C 200°F/93°C 200"F/93°C 175°F/79"C 200°F/93°C 200"F/93"C 175"F/79°C 286"F/141°C 286°F/141°C 200"F/93°C 286°F/141°C 286"F/141°C 200°F/93"C 360°F/182°C 360"F/182"C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68"C None 155°F/68"C 155°F/68°C None 200"F/93"C 200" F/93"C 200°F/93°C 200" F/93"C 135"F/57"C 155°F/68°C 175°F/79°C 155°F/68°C VdS 200°F/93°C None None 175"F/79°C None None 286"F/141"C 200°F/93°C 286°F/141°C 135°F/57"C 155°F/68°C 135°F/57°C 175°F/79"C 155"F/68°C CE 200°F/93°C None None 175°F/79°C None None 286"F/141°C 200°F/93"C 2867/141°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 3 '4LC 'tauiic I P6/ 37 mm 6C 1W! 2W! 41 mm 60 mm victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 mm Max. Hole 2751 mm Mm. Hole NMI 17 rnm Typical Ceiling Tile 30 crm 43 mm Fini5hed Surface MAXIMUM RECESS - 25167 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 24 mm ll Jall.flbw7? 37 mm J1L-L ) 5167 24 mm 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \/taUIiC victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory LJT - 2.4 - - 4 - - - - - t t 6' 4% 1.8rn t t 0 6 * - -t--'- o 3O 3 43 Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 3.0m! 8' 2.4rn 6' Is. 4. 1.2m 2' O.6n 7psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4' e' 0' 10' 12' 14' 16 O. 6n, l.2n 1.0n 2.4n 3Dm 3.7mn 4.3nm 4gm NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 5 .,j(tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - °FI°C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135°F157°C 100°F/38°C Orange Ordinary C 155°F/680C 100°F/38°C Red Intermediate E 175°F/79°C 150°F/65°C Yellow Intermediate F 200°F/93°C 150°F1650C Green High J 286°F/1410C 2251F 81107°C Blue Extra High 7 K 360°F1182°C 300°F/149°C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent V2707, V2708 Recessed Pendent V2703, V2704 upright WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For O minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610.559.3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 6 \041tauIic Bull Moose Tubes® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED <> APPROVED 1] A ONFM NFPA 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE 0.0. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 11/4 1.660 1.442 991 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 - 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 - 2 - 2.375 2.067 1.00 3.66 lbft 5.114 30 2.1/2* 2.875 2.468 1.00 - 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 ' 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 Onty available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas TX MasuW ON SL PJN000 TheE COMPANY 63017 Bull Moose Tube'sO Eddythread40® ADVANTAGES OF BULL MOOSE TUBE® EODVTHREAD 40® is a lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASIM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvani2ed to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAO 40® SPECIFICATIONS c®us LISTED NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR La/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 11/4 1650 11.418 100 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVED [;] AQ!F1A NFPX For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Ci3 t Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grande, 42 Dallas Dl Masuix OH euls Moose ,UBECO.MPA-JV 63017 Bull Moose Tubes® Eddylite® is a lightwall threadable pipe manufactured in NPS 1 through 2.Eddylite® is truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVED (;;] A ONFSA NFPA 6 ADVANTAGES OF BULL MOOSE TUBE® EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED - PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 r4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 'Corrosion Resistance Ratio per latest AL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO KenthVA Casa Grande, AZ Dallas IX Masury. OH BLLLMOOSE TUBE CCMPANV 63017 Bull Moose Tubes® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® is a specially engineered Certified to ASIM Al 35 and A795 Type E, Grade A. replacement for Schedule 10. FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD U® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR PER FT. WI. SIZE an opportunity for downsizing and further cost savings. 11/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 -- 3 3.500 3.334 1.00 - 3.361 7.144 19 - 4 4.500 4.310 1.00 - 4.968 11.290 19 - *Corrosion Resistance Ratio per latest LII Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED APPROVED no A-. ONFSA NFPA ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com - - Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Cam Grande, AZ Dallas, TX Masurp OH SLSL MOOse TUB500MPANY 63017 7 Bu' Moose Tubes® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBED ULTRA EDDY® a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 -, 1.660 1.546 - - 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 ' 2.375 2.261 1.00 1.604 3.344 37 * Pressfit is a Registered Trademark of Victautic Company of America "Corrosion Resistance Ratio per latest ui Directory Listing c®us LISTED APPROVER U;] ONFM NFPA 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masory OH 63017 le c®us LISTED <*> APPROVED NFPA NIPS (IN) 1 1-114 1-1/2 2 2-112 3 4 0.06) 1.315 1.660 1.900 2.375 LD.(in) 1.201 1.546 1.786 2.261 ULTRA EDDY" EWeii(lb/ft) 0.868 1.107 1.274 1.604 Water Filled Weight (lb/It) 1.359 1.920 2.360 3.344 C.R.R.2.17 1.40 1.11 1.00 -. 1.660 1.900 2.375 2875 3.500 4.500 10(m) 1530 1728 2.203 2.705 3.334 4310 F7ED-DY -70 . 1.222 1.844 2.330 2.809 3.361 4.968 Wa..igh(l 2.019 2.860 3.982 5.299 7.144 11.290 - CR0. . 1.98 3.44 2.78 1.66 1.00 1.00 0Dfl n) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 .0(m) 1.097 -1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE EmptyWeightOb/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 Water Filled Weight (lb/fl) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 CA.T - - 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1r 00 (in) 1.315 1.660 1.900 2.375 LOAn) - 1.137 1.482 1.712 2.177 EDDYLITE rnptyWeight(lb/ft) 1.260 1.617 1.967 2.617 Water Filled Weight (lb/It) 1.700 2364 2.965 4.230 PDD . C.R.R. 0.13 0.08 0.12 0.16 0.0(m) 1.295 1.650 1.900 2.375 LD./n. 1.083 1.418 1.645 2.123 EmptyWeight(lb/It) 1 461 2070 2547 3308 Water-FilledWeightflb/ft) 1.860 2.754 3.468 4.842 (.8.8. 1.00 1.00 1.00 1.00 00(m) 1.315 1.660 1.906 2.375 2.875 3.500 4500 - -- 1.049 1.380 1.610 2.067 2:4693.068 4.026 SCHEDULE 40 Empty Weight ljb/ftL. 1 680 2270 2720 3660 5.800 7.580 10.800 Water-Filled Weight (lb/ft) 2.055 2.918 . 3.6025.1147.875 10.783 . 16.316 1.00 1.00 1.0 1.00 1.00 For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U t 819 Clarkson Read Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury OH BIAS M009ETUSS COMPANY 63817 9 c®us LISTED APPROVER [;] AQ4!f4 NFPA 10 NPS PIPE TYPE WEIGHT PER FOOT PIECES PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE ULTRA EDDY® 1 0.868 91 1,659 1,896 1,975 SCHEDULE10 j 1410 91 2695 3,079 3,208 1 EDDYLITE® ' 1.260 91 2,408 2,752 2,867 :EDDYTHREAD4o® 1.461 70 2,148 2,454 2,557 5CHED1JLE40 1.680 70 2,470 2,822 2,940 'ULTRAEDDY®1 1.107 61 1,418 1,621 1,688 EDDY FLOW® 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2,760 1-1/4 EDDYLITE® 1.617 61 2,071 2,367 2,466 'EDDHREAD4O®' 2.070 51 2,217 2,534 2,639 SCHEDULE 40 - 2.270 51 2,431 2,778 2,894 ULTRA EDDY® 1.274 61 1,632 1,865 1,943 EDDYFEOW®1 1.844 61 2,362 2,700 2,812 SCHLDUE10 2.090 61 2,677 3,060 3,187 1-1/2 EDDYLITEr 1.967 61 2,520 2,880 3,000 E6DYTHREAD40' 2.547 44 2,353 2,690 2,802 SCI-IE66LE 43 2.720 44 2,513 2,872 2,992 ULTRA EDDY 1.604 37 1,246 1,424 1,484 EDDYFLOV 2.330 37 1,810 2,069 2,155 SCHEDULE 10 2.640 - 37 2,051 2,344 2,442 2 - EDDYUTE® 2.617 37 2,033 2,324 2,421 EDDYTHREAD4 3.308 30 2,084 2,382 2,481 SCHEDULE40 3.660 30 2,306 2,635 2,745 7 EDDY FLOW® 2.809 1,770 - 2,022 2,107 2-1/2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 L_SCHE1DUE40 5.800 3,654 4,176 4,350 EDDY FLOW 3.361 1,341 1,533 1,596 3 ',_ SCHEDULE 10 4.340 19 1,732 1,979 2,062 L_ SCHEDULE40 7.580 3,024 3,456 3,601 EDDY FLOW® 4.968 1,982 2,265 2,360 4 SCHEDIJLE1' 5.620 19 2,242 2,563 2,670 ji SCHEDULE 40 10.800 4,309 4,925 5,130 SCHEDULE 10 9.289 10 1 951 2 229 2 322 8 1 SCHEDULE1&T 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, AZ. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpii') lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 201!. 25ft. 30 ft. 35f1. 401t. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 13.00 . 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 440 360 309 258 40 40 40 40 36 32 30 28 26 25 ff 549 648 531 455 381 40 40 40 2423 809 40 37 34 31 29 28 26 1235 1012 867 726 40 40 40 2524 1544 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 11.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 312 250 205 175 147 40 40 40 T20 11/2 37 33 30 28 26 25 23 22 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED APPROVER 141 A Wr 0 NMA NFPA For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas. TX Masury, OH 63017 11 FireLock® Outlet-T ®<a> ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1'A through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the 00 of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300psi/2068kPa and VdS rated up to 16bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com \/(ctauIic viciuic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2005 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG 10.52_1 IRS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS II. •ir j. 8 MIA 1¼ 1/5 1 3A6 1.30 1 1.83 1.10 3.87 1 2.56 1 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 4 0.45 3/~ 1 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 279 98.3 65.0 0.50 1 1 3A6 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 1 316 38.6 1,42 55.4 j 1.95 27.9 1.22 98.3 4.08 65.0 2.55 0.54 1.2 11/2 ½ 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/4 13A6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 1/,6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 1 41.7 1.66 58.4 2.19 31.0 1.46 ' 103.6 4.60 65.0 2.56 0.59 1.3 2 ½ 50 15 30.2 42.2 55.6 37.1 1 116.8 65.0 0.59 3/4 13A6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 F + t + 1 1 I 1.88 2.54 1.46 4.60 . 2.56 1.5 25 30.2 131,6 ' 47.8 1.91 + 64.5 ' 2.44 37.1 1.71 116.8 5.40 65.0 , 2.56 0.68 1.6 21/2 x ½ 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 , , ~ 1 /,6 1.89 , 2.44 J 1.71 5.40 , 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 t + S 'F i 1 1 2.13 2.79 1.71 5.40 = 2.56 1.6 25 30.2 131,6 . 54.1 1.91 70.9 , 2.44 43.4 1.71 137.2 5.50 65.0 2.56 0.73 1.6 ½ 76.1 mm K 15 30.2 48.5 ' 62.0 43.4 139.7 65.0 0. - 73 3/4 131,6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 ' 43.4 139.7 65.0 0.73 1 1/,6 , 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 434 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. uctaulic 10.52_2 REVG IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com '\J(tauIc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the I-lOU Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 iCtaUlic VICTAULIC Is A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2000 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 11A11.Iii (1Lsi IflTJitiiIi IiiIiip bMITH COOPER INTERNATIONAL Ductile Iron Threaded Fittings Specifications i branded duct•i,e iron threaded fittings are UL Listed and FM Approved at 300 psi Rated to 306 WSP C Ductile iron castin U0 L us gs conform tc AITM A536 LISTED Fitting dirnensicns conform to. ASME B1&3 Bushings and plugs conform to ASME B 16.14 FM Fittings are :00% air :ested APPROVED NPT threads on all ñttings coniorm to ASME BL2O. 1 Independent lab verca:ion that ftttbgs meet applicable chemical & pbisical properties Manufacturing I acilit:s are ISO 00:208 and ISO 14001 Temperature Dere F working Pressure. 1onshok pLG 300# Class Threaded Fitlins -2):: 100 500 15C 2CC 480 250 460 440 420 - 400 400 450 . 360 550 340 500 320 ________ 550 300 c®uS APPROVED Fig. 35E3-90° Elbow LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35E 3004 35E 3006 1.13 100 200 0.2 131 70 140 03 1 - 1-1/4 35E 3010 35E3012 35E3014 35E 3020 35E 3024 1.50 - 40 80 0.5 1.75 25 50 0.8 1-1/2 2 2-1/2 1.94 18 36 20 8 1.1 2.25 2.70 10 4 1.8 3.2 - IA Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner I Master 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 - 1 x 1/2 1 x3/4 35RE3010004 1 26 1 36 70 50 35 140 100 04 35RE3010006 1.38 1.45 0.4 0.5 1-1/4 x 1/2 35RE3012004 1.34 1.53 70 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 60 0.6 0.7 1-1/4x1 35RE3012010 1,58 1.67 30 1-1/2x1/2 1-1/2x3/4 35RE3014004 1.52 1.75 30 60 50 0.6 0.7 35RE3014006 1.52 1.75 25 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 11/4 35RE3014012 1.82 1.88 18 36 36 10 2 x 1/2 35RE3020004 1.60 1.97 18 1.0 2 x 3/4 2 x 1 2x1-1/4 - 35RE3020006 1.60 1.73 1.90 1.97 18 16 12 36 32 24 1.0 1.2 1.3 35RE3020010 35RE3020012 2.02 2.10 2x1-1/2 35RE3020014 35RE3024014 I 2.02 2.16 10 20 1.5 2-1/2x_1-1/2 2.16 2.51 6 12 2.2 35RE3024020 __2-1/2x2 2.39 2.60 6 12 2.5 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 1 1-1/4 35F 3006 35F3010 35F 3012 098 1.13 80 40 160 80 03 0.5 0.7 1.29 25 50 40 20 1-1/2 35F 3014 35F 3020 1.44 1.69 20 10 1.0 1.6 2 2-1/2 35F 3024 1.95 4 8 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 35T 3006 1.31 30 60 0.5 1 351 3010 1.50 25 50 20 0.7 1-1/4 35T 3012 1__75 10 11 1-1/2 3513014 1.94 10 20 1.5 2 2-1/2 35T 3020 35T 3024 2.25 2.70 6 4 12 8 2.4 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com C&US <~> APPROVED Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 1x1/2 1x1/2x1 1 x3/4 i x 3/4x3/4 1x3/4x1 35RT3006004 35R13010004 35R13010004010 1.20 1.20 1.22 1.36 60 120 60 60 50 70 50 40 50 30 40 30 50 0.4 0.6 0.6 0.6 0.6 -0.7- 0.8 0.9 0.9 1.0 10 0.7 1.26 1.50 1.38 1.38 1.50 1.34 1.26 1.36 30 30 25 35 25 20 25 15 20 15 25 1.50 1.45 1.45 1.50 1.53 1.75 1.62 35RT3010006 35RT3010006006 35813010006010 1.38 1.31 1.45 1.34 1.53 1.45 1-1/4 x 1/2 35R13012004 1-1/4x1/2x1-1/4 1-1/4x3/4 35RT3012004012 35RT3012006 1.75 1.45 I-1/4x3/4x1-1/4 1-1/4 x 1 1-1/4xlxl/2 35RT3012006012 35RT3012010 35RT3012010004 1.75 158 1.62 158 1.75 167 1.53 1.34 1.26 1-1/4x1x3/4 1-1 /4xlxi 1-1!4x1x1-1/4 1-1/2x1/2 1-1/2x 1/2x 1-1/4 1-1/2x 1/2x 1-1/2 1-1/2x3/4 1-1/2x3/4x1-1/4 35813012010006 20 35R130110 010 1.45 1.38 1.50 1.63 1.69 1.75 20 20 15 16 24 12 16 20 18 12 20 16 16 12 40 40 30 32 48 24 32 40 36 0.8 0.9 - 1.0 1 .58 35813012010012 35RT3014004 35R13014004012 35R13014004014 35R13014006 358T3014006012 1.75 1.69 1.41 1.81 1.94 1.52 1.41 1.56 1.66 1.66 1.88 1.94 1.0 1.1 1.2 1.1 1.1 1.2 1.2 0.8 0.9 1.0 1.2 1.3 1.4 0.9 1.0 1.1 1.3 1.4 1.5 1.6 1.7 1.9 1.9 2.0 2.1 1.3 1.4 1.5 17 1.8 1.52 1.75 1.88 1.94 1.94 1.66 1.75 1-1/2x3/4x1-1/2 1-1/2x1 1-1/2xlx1/2 1-112x1x3/4 35813014006014 35RT3014010 35R13014010004 1.94 1.65 1.65 1.25 1.44 1.50 1.67 1.80 1.69 1.75 24 40 32 32 24 24 24 32 - 32 32 28 28 20 20 16 16 16 16 16 20 20 16 16 16 1.44 35813014010006 35RT3014010010 358T3014010012 1.50 1.65 1.82 1-1/2x lxi 1-1/2xlxl-1/4 1.80 1.88 1-1/2x1x1-1/2 1-1/2x 1-1/4 1-1/2x1-1/4 x1/2 l-l/2x1-1/4x314 1-1/2x1-1/4x1 35RT3014010014 35R13014012 35RT3014012004 1.94 1.82 1.41 1.80 1.82 1.34 1.94 1.88 1.66 12 12 16 35RT3014012006 35RT3014012010 1.52 1.65 1.82 1.45 1.58 1.75 1.88 1.75 1.80 1.88 1.94 1.88 16 16 14 14 10 10 8 8 8 8 8 10 10 8 8 8 1-1/2x1-1/4x1-l/4 1-1/2x1-1/4x1-1/2 2x1/2 2x 3/4 2x 1 - 35R13014012012 35R13014012014 35R13020004 35R13020006 35RT3020010 1.94 1.49 1.60 1.49 1.60 1.97 1.73 2.25 1.73 2.02 2x1 x2 2x1-1/4 2x1-1/4x2 2x1-1/2 2x1-1/2x1/2 358T3020010020 2.02 2.25 35R13020012 358T3020012020 35RT3020014 1.90 1.90 2.10 2.25 2.16 2.25 2.10 2.02 2.02 35RT3020014004 1.49 1.41 1.88 2x1-1/2x3/4 2x1-1/2x1 2x1 1/2x1 1/4 2x1-1/2x1-1/2 35R130200106 40 35R13020014010 1.60 1.73 1.52 1.97 2.02 1.65 35R13020014012 35RT3020014014 190 182 1.94 210 2.16 2.02 I UL !iIUI! Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x 1 x 1-1/4 1 x 1-1/2 1-1/4x1x1-1/2 35613006010 35 _BT 3010012 1.45 1.67 1.80 1.45 1.67 1.37 1.58 1.65 1.82 30 20 15 15 60 40 30 30 30 0.6 0.9 1.0 1.2 1.3 1.6 1.8 1.8 35BT3010014 35813012010014 1.80 1.88 1.88 1.80 1-1/4x1-1/2 1-1/4x2 1-1!2x1-1/4x2 l-1/2x2 35B13012014 1.88 1.82 15 10 10 8 35B13012020 2.10 2.16 2.10 2.10 1.90 20 20 16 35BT3014012020 2.02 35BT3014020 2.16 2.16 2.02 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 2.06 40 80 0.6 2 x 1 (not hex) 35RC3020010 2.81 20 40 1.0 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 35HB3010004 1.06 180 360 360 0.2 1 x 3/4 1-1/4x1 1-1/2x1 1-1/2x1-1/4 35HB3010006 35HB3012010 35HB3014010 35HB3014012 35H83020010 1.06 1.19 1.25 1.25 1.38 180 0.1 90 75 75 40 40 40 180 150 150 80 80 80 0.2 0.4 0.3 0.6 2 x 1 2 x 1-1/4 35H83020012 1 35HB3020014 1.38 1.38 0.6 0.6 2x1-1/2 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 35SP3004 35SP3006 35SP3010 35SP3012 0.94 600 350 1200 700 400 200 160 90 0.07 0.1 0.1 0.3 0.4 0.6 1.12 1.25 200 1-1/4 1-1 /2 2 1.37 100 35 SP3014 35SP3020 1.44 80 1.50 45 ~Srget000do ZINC 4,_ c®uS <e> APPROVED Fig. 3503 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 350P3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 - 2 35CP3020 2.62 30 1.2 15 2-1/2 35CF3024 3.00 9 18 2.2 I . Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 1-1/2 2 35U 3010 35U 3012 35U 3014 35U 3020 2.19 20 15 40 30 20 12 1.0 1.2 1.7 2,50 2.62 10 6 12 2.4 - 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com B B 0 Mw . ) .-1-- - Size in Part Number ________ A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 35C 3006 0.97 1.16 200 110 400 220 0.1 0.2 1 35C 3010 1-1/4 35C 3012 1.28 70 140 0.4 35C3014 - 1.33 1-1/2 50 100 0.5 2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BCS - Beam Clamp III C@Ul <e>. APPROVED A A Fig. 35X 3- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 - 1.50 20 40 0.9 1-1/4 35X3012 12 24 1.4 1.75 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2.8 Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight I lb Inner I Master 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.? 1-1/2x1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1.73 8 16 2.0 Fig. 35C 3- Cap Size in Part Number A in IPacking Weight lb I Inner I Master 3/8 35BC3003 0.75 100 200 0.3 1/2 35BC3004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX(323)890-4456 • www.smithcooper.com 114 [INSTALLATION STEPS - ZOMINTO WOOD & STEEL: I [INSTALLATION STEPS -I !]Jt INTO WOOD & STEEL Insert the appropriate nut driver into a 318" or 112" portable drill. Insert the SAMMYS" into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position Push the face of the nut driver tight to the member Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4' 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque t020 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel. INSTALLATION STEPS !LjjIiNjINTO CONCRETE] Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4' 3/8", 1t2' or metric all thread rod or bolt stock. (#I4SW red nut driver used with 112" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw [INSTALLATION STEPS -Oi o11ibINTO CONCRETE: Using an SDS 250 carbide lip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammerl rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW (red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact'drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SING screw is ready to receive 1/4", 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum.RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener M1i1iIMlIJlEilRili1lI1H1 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique Spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMY FOR STEEL 1 r.Td,pre- reqtilred 61 ling Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. 'Made in the U.S.A. Wat a video demoost,atioo at wwwitwbuiidex.com #14 Black Nut Driver Part # 8113910 1/4" 8024957 DSTR 100 * 1/4-20 xl" TEKS 3 1510 (20 ga.) .036-20 ga 3/16" 25 125 1/4 8025957 DST 100 1/4-14 x V TEKS3 446 (20 ga.) .036%20 ga 3/16 25 125 1/4 8026957 DST 150 1/414x1 1/2 TEKS3 970 (16 ga.) .036"-20 ga 3/16 25 125 1/4 8027957 DST 200 1/4-14 s 2 TEKS 3 446 (20 ga) .036-20 ga 3/16 25 125 1/4' 8030957 TEK 500 - 12-24 x 1-1/2' TEKS 5 3125 (3/16') .188"-3/16" 1/2" 25 125 3/8 8038957 DSTR 1 114-20 xl TEKS 3 1510 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125 €" 3/8" 8037957 DSTR 1-1/2 * 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060-16 ga. 1/2' 25 125 O 3/8 8039957 DSTR 516 5/16-18 xl 1/4 TEKS 3 2200 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125 3/8" 8040957 DST 10 1/4-14 xl" TEKS 3 446 (20 ga.) .036-20 ga 3/16" 25 125 970 (16ga.) 3/8' 8077925 DST 10-SS 1/4-14 x TEKS 3 446 (20 ga.) 970 (16 ga.) .036-20 ga 3/16' 25 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2" TEKS 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8078925 DST 15-SS l/4-14x1-1/2" TEKS 3 446 (2004.) .036"-20 ga 3/16" 25 125 3/8' 8042957 DST 20 l/4-14x2" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8' 8043957 DST 25 1/4-14 x 2-1/2" TEKS 3 446 (20 .036"-20 ga 3/16' 25 125 3/8' 8044957 DST 30 1/4-14 x 3" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 tt).497 DST 516 xl1R1Rol-1!4"TEKS 3 100 111"1 Inns 1475 125"-1/8" /16" 7 19 ENO L 'CO' 3/8 8046957 TEK 50 1224 x1-1 /2 TEKS5 3125 (3/16) 1500 1475 .259'-1/4' 1/2 25 125 1/2" 8031925 DST 2.0 1/4-14 x 2"TEKS 3 446 (20g3.) .188"-3/16' 970 (16 ga 1/4" 25 125 L _ 1/2" 8033925 DSTR 1.0' 1/4-20 xl" TEKS 3 1510 (20 ga.) .036-20 ga 3/16" 25 125 1/2 8034925 DSTR 516 5/16-18 x 1/4 TEKS 3 2220 (20 ga) .036'-20 ga 3/16 25 125 1/2' 8035925 DST 5.16 5/16-1851-1/4' TEKS 3 1500 (3/16") .125'-1/8" 3/16" 25 125 #14 SW Red 1/2" 8036925 TEK 5.0 12-24x1-1/2"TEKS5 3125 (3/16") - .188-3/16" 1/2" 25 125 Nut Driver Part #8114910 "Includes retaining nut oilS SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides each time. When the face of the driver comes into contact with the material you are installing into, continue drilling a fast and safe installation until nut driver spins eoee us tree. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. Allows 17° deflection from vertical. Made in the U.S.A. Watch a video demov,ohalionat www.itwbulldex.com 2AHHT,Zt 0 ggj'flL'.I!L'JI fl'A'I'fl'tH'IL't• Made with Teks® self-drilling fasteners - no pre-drilling required. o Installs into steel range from 20 gauge - 1/2" thicknesses. - - - ril 11119 A standard screwgun with a depth sensitive nosepiece should be used to pie- required install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. wITh qJ7Z I Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Wat havideodemonst Ii vat Made in the U.S.A. www.itwbuildex.com oil= — 1/4 8047957 SWD 100 114-14 x TEKS 3 1477 (16 ga) .060"-1 6 ga 3/16 25 125 1/4 8049957 SWDR 100 * 1/4-20 x TEKS 3 1900 (20 ga.) .036-20 ga 3/16 25 125 3/8 8050957 SWD 10 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060"-16 ga 3/16' 25 125 3/8 8080925 SWD 10-SS 1/4-14 x 1" TEKS 3 1477 (16 ga.) .060'-16ga 3/16 25 125 3/8' 8051957 SWD 15 1/4-14 x 1-1/2' TEKS 3 1477 (16 ga.) .060"-16 ga 3/16 25 125 3/8 8052957 SWO 20 1/4-14 x 2" TEKS 3 1477 (16 ga.) .06016 ga 3/16 25 125 3/8" 8053957 SWD 516 5/16-18 x 1-1/4" TEKS 3 2480 (20 ga.) .036"-20 ga 3/16" 25 125 3/8' 8055957 SWDR1 1/4-20 x TEKS 3 - 1900 (20 ga) 1500 1475 .036-20 ga 3/16' 25 125 #14 SW Red rf€' 3/8 8054957 SWDR 1-1/2 * 12-24 x 1-1/2 TEKS 5 2375 (3/16') 1500 1475 .188"-3/16" 1/2" 25 125 Nut Driver - -'€' 3/8" 8056957 SWDR 516* 5/16-18x1-114 TEKS3 2480 (26 ga.) 1500 - 1475 .036"-20 ga 3/16 25 125 Part# 8114910 3/8' 8057957 SWT 15 12-24 x 1-1/2' TEKS 5 2375(3/16') .188"-3/16" 1/2' 25 125 "Includes retaining nut 410 Rod Part Screw, Approvals Size Number Model Descriptions UI-- #14 Black Nut Driver IS° 3/8" 8137957 SHDSTR1* Part # 8113910 L 318" 8268957 SH-TEK 50 12-24x1-3/4' TEKS 5 ! 1 1/2" 8270957 SH-TEK 5.0 12-24x1-3/4" TEKS 5 #14 SH Orange L Nut Driver Part #8273910 'Does not comply with ROHS requirements /Includes retaining nut 2368(1/2" steel Vertical) 1306(45" off Vertical) 1500 (Vertical) 4" 3/16" 1/2" 25 125 2281 (3/16° HSS) 850(45' off Vertical) 2-1/2" 1585 (3/16" HSS 45" off Vertical) 2368 (1/2° steel Vertical) 1306(45" off Vertical) 3/16" 1/2" 25 125 2281 (3/16" HSS) 1585(3/16" HSS 45" off Vertical) 1/4-20 Xl" TEKS3 3220 (3/16") 1500 1475 .035" 3/16" 25 125 H " SAlViflhlY K-PRESS Installs into Metal Deck, Purl/n, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or pudin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. god ~yl~l UM~Jfe~Nt ,' r'65`miwi PM,Test K —Min a ox ENN-b-7611 Fu , ~eadT(Ii) 4 01 ty T3 Caw Appticahor ERTIC1OUNT Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. €.wavh a video demonst,ation a! www.itwbuildex.com 4 'S' 3/8" 8153922 XP 35 Sammy X-Press 35 318" 8150922 XP 20 Sammy X-Preso 20 1146 (22 ga) 185 )Luminaire) 250 (Luminaire) .027" .056" .125" 25 125 Metal Deck 850(2W Pipe) .027" 940 (2" Pipe) .029" 1146 122 ga) 185 ILuminaire) 250 )Luminaire) .027" .056" 1475 (4" Pipe) .104" .125" 25 125 Metal Deck 283 (Conduit & Cable) .029" 1500)4" Pipe) .060" 1783 116 ga) 185 )Luminaire) .029 940 )2" Pipe) .029" .125" 25 125 Pudin 250 )Luminaire) .056" 1475 (4" Pipe) .104" 416 (Conduit & Cable) .059" - - -- - Pre-Pour Structural C000rete@ 3000 psi - Metal Deck (Pre-Pour) 1146 (22 ga) 850 12/a Pipe) 25 125 Metal Deck Pout-Pour Range If LWC!5 35 PCF )lbslft') - . - .._.... )Post-Pour) 1/4" 8181922 XP 200 Sammy X-Press 200 4.. 42 3/8" 8150922 XP 20 Sammy X-Press 20 Pre-Pour Structural Concrete @3000 psi Post-Pour Range U LWO:5 35 PCF fibs! ft'I The SidewinderX-Press expands to provide "Less jobsite material needed. horizontal attachment in: - . - 16 ga - 3/16" steel - puns, tubular steel, • No retaining nut required. - Installs in seconds with Sammy X-Press It® Too), "Provides design flexibility. saving time & installation costs. "Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof (SWXP) deck, tubular steel, or vapor barrier fabric. Walcl, a video denr000tation at ..,i www.itwbulldex.com 1250 (3W Pipe) 3/8" 8293957 SVVXP35 Sidewinder 1798 (16X-Press 35 ga) 80 )Luminaire) .059" .125" 25 125 Podia 416 (Condoit & Cable) - O $AOEINOSAY for çen1e or roof ptches The Swivel X-Press allows you Less jobsite material needed. to hang plumb in extreme roof pitches: - 89" in z-purlin No retaining nut required. - 45" in metal deck for 12/12 pitch Provides design flexibility. Installs in seconds with Sammy X-Press It5 Tool, saving time & installation costs. Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof ..Warcho,ideodmonst,a5o,i\ deck, tubular steel, or vapor baffler fabric. www.itwbuildex.comJ 750(2" Pipe) 3/8' 8294922 SXP 20 Swivel 61(2g: 170 Vertical lLuminairet .029' 635 Pipe( 25 .125' 125 Metal Deck X-Press 20 829 (45' Off VerQ 80@ 45" (Luminaire) (2' .029' 283 Vertical (Conduit & Cable) 233 @ 45" (Conduit & Cable) 1250 (3-1/2' Pipe( S' 3/8' 8295922 SXP Swivel 1675 (16 ga 250 Vertical (Luminaire) .059' .029" .125" 25 125 Pudin X-Press35 1558 (9" Off Vert) 500 Vertical (Conduit & Cable) 635 (2' Pipet - 333 @ 89" (Conduit & Cable( 1/7 8272957 SXP 2.0 Swivel 1061 (22 ga Vert) .027" .125" 25 125 Metal Deak x-Press o 1/2' 8271957 SXP 3.5 Swivel X-Press35 1675 (16 ga Vert) 1558(89" Off Vert) .860' .125" 25 125 Pudin j r I - ' \: . I 'The Sammy X-Press expands to provide I V direct vertical attachment in: 1. / I ..i• . - - metal deck (22-16 gauge) I \ -z-purlin(18-l6gauge) 'Made in the U.S.A. 16 8194910 - UXPIT" Universal X-Press It Tool 8152910 XPDB 25/64 Drill Bit "Toot Includes: Sleeve, Bit Receiver, Hue Wrench, and 25184" Drill Bit APPROVALS 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/7 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST25-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-1/2"- 4"" 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3""" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" 1 8038957 DSTR 1 3/8" Vertical 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" Vertical - 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" - Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDF. 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK5O 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 4" 1475 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4 1475 8294922 SXP 2) 3/8" Vertical or up 1045" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical orupto89" 3-1/2" 1250 .06C" 2" 635 .029" 8293957 SWXP35 3/8" Hotizontal 3-1/2" 1250 .060" (SAMMYS FOR CONCRETE PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Hotizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000p5i 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC 35 PCF (lbs/It3) 185 .027" 8150922 XP 20 3/8" Vertical 250 .035" 185 .027" 8153922 XP 35 3/8" Vertical 250 .035" 185 .027" 8181922 XP 200 1/4" Vertical 250 .035" Vertical 170 .027" 8294922 SXP 20 3/8" 45" 80 .027" Vertical 250 .060" 8295922 SXP 35 3/8" . 90" 80 .060" 8293957 SWXP 35 3/8" Hotizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXF 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXF 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Hotizontal 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4316- Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Complies w/ NEC Standards 1Sheet Steel tGauges Gauge No. 22ga. 20ga. 18ga. 16ga. 14ga. 112ga. 1I8" 3116" 114" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" SWG 25-3e0 Maximum pipe size in composite wood joist allowed by UL is 3-l/T UL compliance with NEC Standards. SWG 25-380 Maximum pipe size in wood ember or joist allowed by UL is " UL and FM tests were performed in compliance with NFPA 13 Standards. ""5WC 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" SWG 20 Maximum sine size in wood ember or ioiot allowed be UL is 3' Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pie-drilling NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com omi Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products wwrapwx Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/ADorovals KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 33.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACl 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor AVPRffB Indeoendent code evaluation IBC®/ IRC®2015 IBC®/ IRC®2012 IBC®/ IRC®2009 IBC®/ IRC 2006 L3•37. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 33.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter d bit in. 1/4 Nominal embedment hnø,c in. 1-5/8 2-1/2 Effective embedment het in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T Inst ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 Tcet is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size Table 2 - Hilti KWIK HUS-EZ I design strength with concrete/ pullout failure in uncracked concrete' 2,3,4,5 Nominal Nominal Tension - 4N5 Shear - On anchor embed. f'c = 2,500 psi f = 3,000 psi f', = 4,000 psi f' = 6,000 psi f' = 2,500 psi f = 3,000 psi 1' = 4,000 psi I', = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete/ pullout failure in cracked concrete' 2'3'4'5 Nominal Nominal Tension - N5 Shear - On anchor embed. f' = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f = 2,500 psi f = 3,000 psi f' = 4,000 psi f', = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in, in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, A. = 0.68: for all-lightweight, A. = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a5,els = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aN, = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear' Seismic shear' diameter thread diameter 4N in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 / UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension cpN 5 A N ft as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V,5 < 0-6(pAv c, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with a q 0.60 A,,5 55 as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Huh, Inc. (us) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.37 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear (Ito and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 uncracked concrete fAN f RN 'NV 'RV mV fRy Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h (mm) (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a fl/-a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 _______ 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 _______ _______ 0.70 0.63 0.68 0.88 n/a -- '' 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 1 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 7 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 0.98 5-1/2 (140) 0.83 0.72 0.93 6 (152)__ 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CO 10 (254) 0.89 CL 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6- Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .1. toward edge from edge factor in shear4 cracked concrete 'AN 'RN 1AV fRy 'RV fRy Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 1 0.80 0.43 n/a . n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 1 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 1 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 ______ 0.93 6 (152) 1.00 0.86 0.74 ______ 0.98 7 (178) 0.92 0.78 ______ 1.00 8 (203) 0.98 0.82 _______ 9(229) 0.86 _______10 1.00 (254) _______ _______ _______ _______ _______ 0.90 _______ M ________ (279) _______11 0.94 _______ 12 (305) 0.98 14 (356) _______ 1.00 ______ 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, IAV assumes an influence of a nearby edge. If no edge exists, then I AV 4 Concrete thickness reduction factor in shear, I NV assumes an influence of a nearby edge. If no edge exists, then f = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck1'2'3'4'5'6'7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - cpN Shear - V,, Tension - 4N ,, Shear - anchor thread embed. f'= 3,000 psi '= 4,000 psi f'0 = 3,000 psi f= 4,000 psi F= 3,000 psi f' = 4,000 psi f= 3,000 psi = 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) I lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) 1 (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soff it of cracked lightweight concrete over metal deck 1'23'4'5'6'7'8 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - 4N Shear - 4V,, Tension - 4N Shear - On anchor thread embed. f',= 3,000 psi f'= 4,000 psi f'= 3,000 psi f'= 4,000 psi r 3,000 psi f'= 4,000 psi f',= 3,000 psi '= 4,000 Ps diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / _____ 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 Min. 4-1/2 \__ \ Minimum 20 gauge steel deck Lower flute (ridge) KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2- Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm. 3/4" - Mm. 3,000 psi sand-lightweight "" "•- - or normal-weight concrete 1, - - - flute I J ' - Upper FAnchor • :'; (typical) - Mm. 12 (typical) Min. 1-1/4" - 1 Anchors maybe placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.37.3.2 Canadian Limit State design 3.3.7 Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile' Shear4 Shear diameter diameter N, V V eq in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile Ne , = ASON 4) f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with < A0 4 0.6 t,. R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with <Aw.v 4, 0.6 tt, R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. 1/4 d in. (mm) (64) Effective embedment2 h 01 in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h , in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness hmj in. 3-1/4 4-1/8 (mm) (83) (105) Critical edge distance c in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 (mm) (38) Minimum edge distance c,,. in. 1.50 In (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 I 2-7/8 (mm) (51) (73) Minimum specified ultimate strength futa psi 125,000 (N/mm2) (862) in 0.045 Effective tensile stress area A 6 (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3,370 Factored steel resistance in tension N D.6.1.2 (kN) (15.0) Factored steel resistance in shear V lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V q (kN) (1.5) lb 725 Factored steel resistance in shear V r D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete kc.cr - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 qJ0 - 1.0 D.6.2.6 Anchor category - - 3 1 1 D.5.3 (C) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (C) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete6 N pr,ucr lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete6 N lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 N pr,eq lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC.ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with GSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex D section D.2. For all design cases, 4J6 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete must be used. For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qJ0 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1 .4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2,3,4,5 Nominal __________ Tension - N Shear - V = 20 MPa f = 25 MPa f = 30 MPa f = 40 MPa f'c = 20 MPa f', = 25 MPa f, = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure 11-4 in cracked concrete 1,2,3,4,5 Nominal Tension - N, Shear - Vr __________ f'0 = 20 MPa f, = 25 MPa I = 30 MPa f = 40 MPa f' = 20 MPa f'c = 25 MPa I = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A a as follows: for sand-lightweight, k = 0.68; for all-lightweight, X. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - N,ses 0.75 See section 3.1.8.7 for additional information on seismic applications. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hitti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4r5,6,7 H Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N Shear - V Tension - Nr Shear - Vr anchor thread embed. f'c = 20 MPa f = 30 MPa I',, = 20 MPa f = 30 MPa f', = 20 MPa f'c = 30 MPa f'c = 20 MPa f = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck1'2'3'4 '6'7'8 H Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N ___________ r Shear - V ___________ __ Tension - N Shear - V anchor thread embed. IC = 20 MPa IC = 30 MPa IC = 20 MPa IC = 30 MPa I' = 20 MPa IC = 30 MPa IC = 20 MPa IC = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 4 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 / UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) See Section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). Tabular value is for lightweight concrete and no additional reduction factor is needed. No additional reduction factors for spacing or edge distance need to be applied. Comparison of the tabular values to the steel strength is not necessary. Tabular values control. Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0NCOIC = 0.75. For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - o, = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. )US) 1-800-879-8000 1 www.us.hilti.com I en espanoi 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels"2 Hanger rod size Mm. effective embedment h, in. Allowable load' Ultimate load Tension lb Shear lb45 Tension lb Shear lb4'5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete Adrnissible anchor location 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 11/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. 3.3.7J' Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13/ie 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13Ae 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved c@ us LISTED Seismic Restraints System Size Range - (Fig. 65 and Fig. 66) 3/8, 1/2 and 5/8 rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8' rod will support 1/2' thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951 .737.0330 II CUSTOMER SERVICE • 800.786.5266 www.tolco.com 1ILJ Fig. 25 - Surge Restrainer c®uS LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 fli COOPER B-Line Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved C@ us usre Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F WtJ100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11h 11630 10370 510 OFFICE/MANUFACTURING FACILITY• 1315 SAMPSON AVE.. CORONA, CA 92879 • PH: 951.7375599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 20021I2 to 200-8 Fig. 200 Fig. 2005 Ijx DIk ix.'a i Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c@ us USTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. / For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4 (20mm) thru 8 (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-1 71 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size 114 A 0 Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Fig. 200F ... 200_1/2 1/2" (15) /8"-16 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200-I4 3/4" (20) /811-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200_11/4 11/4" (32) I811-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-1I2 11/2" (40) /8"-16 3/8° (98.4) 2/8" (73.0) 14 (6.4) 200-2 (50) /811-16 41/2" (114.3) (76.3) 15 (6.9) 200_21/2 21/2" (65) /811-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5 /8" (149.1) 4° (101.6) 29 (13.3) 200_3112 31/2" (90) /8"-16 7I8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 (100) /8"-16 7 /8" (187.3) (127.0) 35 (16.0) 200-5 5" (125) 1/2"_13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"_13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1 1/2"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified I' .. - ••••.'•. . ••. COOPER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - - - - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily / installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) Fig. 200-1 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications VW/-H-171 E & A-A-1 192A Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, .- - Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. tç. ®TOLCtJ C(DUS USTED A Fig. 200-1/2. 200-/4 Fig. 200_2112 to 200-8 tI Rk." 200M8-1/2 1/2 (15) M8 31/8" (79.4) 2/8° (66.7) 11 1 (5.0) 200M10-1/2 1/2" (15) M10 31/8 (79.4) 2I8° (66.7) 11 (5.0) 200M8-3/4 3/4 (20) M8 31/8° (79.4) 21/2 (63.5) 11 (5.0) 200M10-3/4 3/4 (20) M10 31/8 (79.4) 21/2° (63.5) 11 (5.0) 200M8-1 1" (25) M8 33/8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1° (25) M10 3I8" (85.7) 2I8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4 (94.0) 2/8° (73.0) 13 (5.9) 200M10-11/4 11/4 (32) M10 33/4 (94.0) 2/81, (73.0) 13 (5.9) 200M8-1112 11/2° (40) M8 3/8° (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2° (40) M10 3/8" (98.4) 2/81, (73.0) 14 (6.4) 200M8-2 211 (50) M8 41/2 (114.3) 3" (76.3) 15 (6.9) 200M10-2 (50) M10 41/2 (114.3) (76.3) 15 (6.9) 200M-21/2 21/2 (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3° (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2 (90) M10 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (1 00) M10 7 /8° (187.3) 5" (127.0) 35 (16.0) 200M-5 (125) M12 91/8" (231.8) 61/4 (158.7) 66 (30.2) 200M-6 (150) M12 101/8" (257.2) 6/4° (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8' (333.4) 8/4° (222.2) 136 1 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified .,._'i' • _ COOPER B-Line 71 I1111 11111 0 0 I I Ex Aft""N- Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2°_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1l 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pro-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 200H-2-3/8 2 (50) /8"-16 4/16° (115.9) 3/32' (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2"_13 423/32 (119.8) 3/8° (85.7) 45 (20.4) 200H-21/2-3/8 21/2 (65) /"-16 5/16" (134.9) 323/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) /2"-13 515/32" (138.9) 3/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"_13 5/8" (148.1) 331/32' (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4' (100) 1/2"..13 71/32" (178.6) 419/32" (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified COOPER B-Line F PP I® Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61-G FOSK 8YS1tM cOMPAT1BI.E *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 WU © 2012 Fire Protection Products, Inc. FPPP, LubeFit® are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ', Blaze-Master°, FlowGuard Golds and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FOCK SYSTEM COMPAT!BLE *FBC' System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FP(+1800344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com LA MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPP1, LubeRtO are registered trademarks of Fire Protection Products, Inc. FBC'5, BIazeMaster, FlowGuard Golds and Corzan are registered trademarks of Noveon IP Holdings Corp. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. iJihiieaI F1iIJøUETBlTihiie:adLCUfti iirqiøi I F P P I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. um © 2013 Fire Protection Products, Inc. FPPI®, ThreadFif5 are registered trademarks of Fire Protection Products, Inc. LA MADE IN U.S.A.