Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 214; FPC2019-0259; PermitPrint Date: 12/16/2021 Job Address: 2525 EL CAMINO REAL, #214, Permit Type: FIRE-Construction Commercial Parcel #: 1563020900 Valuation: $281,525.03 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: PERMIT REPORT (r,city of Carlsbad CARLSBAD, CA 92008-1208 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0259 Status: Closed - Finaled Applied: 11/14/2019 Issued: 12/03/2019 Finaled Close Out: 02/12/2020 Inspector: Final Inspection: Project Title: Description: SEPHORA - FIRE ALARM TI (ADDRESSABLE, 18 DEVICES) Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov fPc2oLcl // Johnson Controls 3568 Ruffin Road, South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Product Submittal Project: Sephora The Shoppes at Carlsbad 2525 El Camino Real Suite 214 Carlsbad, CA 92008 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.danieIscici.com 11/11/2019 REV.#: 0 PROJECT Johnson Controls 3568 Ruffin Road, South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci. corn Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4009-9601 Nac Repeater 7300-0026:0375 2 4098-9755 Duct Detector 3240-0026:0241 2 2098-9806 Remote Test Switch 7300-0026:0150 3 4090-9010 Relay 1AM 7300-0026:0311 3 49V0-APPLC Strobe 7125-0026:0373 6 49SV-APPLC Speaker Strobe 7125-0026:0384 1 49SVH-APPLC Speaker Strobe 7125-0026:0384 Business Information 11/11/2019 REV.#: 0 PROJECT £LSimplEx UL, ULC, CSFM Listed; FM, NYC Fire Dept Approved* IiUiI4.1 4009 IDNAC Repeaters provide enhanced power delivery to TrueAlert/TrueAlert ES addressable notification appliances controlled by IDNAC SLCs: Output voltage in alarm is maintained by an efficient switching regulator at 29 VDC during both AC input and battery backup conditions allowing strobes to operate at lower current With lower current strobes and regulated output voltage, wiring distance can be extended 2 to 3 times that of conventional notification, appliance loading can be increased, or smaller wire gauge can be used, all resulting in installation savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions 4009 IDNAC Repeaters receive an IDNAC SLC input and provide a repeated 3 A SLC output to extend SLC distance and power: Appliance control and address limit remains with the host IDNAC control panel. Repeater status is communicated to the control panel for system diagnostics and also locally indicated Repeater output extends supervisory capacity by up to 139 additional unit loads or 3 A Input SLC connection can be Class B or Class A Repeater output can be a Class A loop or a Class B output with internal connections for up to four (4) T-tapped output branches (Class A output requires 4009-9814 Class A Adapter) Operation requires one IDNAC SLC address; Repeaters can be connected as one in series, or up to five (5) in parallel AC power input is 120 VAC or 220-240 VAC, 50/60 Hz, auto-select An on-board battery charger is provided with low AC battery disconnect selectable per Repeater (required for ULC listed applications) Operation is compatible with TrueAlert ES and TrueAlert addressable notification appliances and accessories Available with platinum or red cabinet Listed to UL 864 and ULC S527 Multiple wiring options are available: Wiring options include Class B multiple branch (up to 4) output, Class A loop extension, and Class A riser to Class B branches or a Class A loop output When the Repeater is part of a Class A loop from the IDNAC SLC source panel, up to twice the distance for the loop is available; (Class A loop repeating requires 4009-9814 Class A Adapter) This product has been approved by the California State Fine Marshal (CSFM pursuant lvWon 13144.1 xl the California Health and Safety Code See CSFM UsIng 1165 0026:0378 for allowable values and/or cvedtivev concerning material presented in Iris document. NYC Fire Dept COA #6151. Additional listings may be appicabte; contact your local Simplex product suppter for the latest status Usings and approvals under Sippdea Time Recorder Co.are the property of Tyca Fire Protective Products. Additional fstings may be applicable; contact your local Simplex product supplier for the latest status. Ustings and approvals under Simplex Time Recorder Co. are the prop" of Tyco Fire Protective Products. TrueAlert Addressable Notification 4009 IDNAC Repeater; Power and Distance Extender FINN , Extended distance and current "RI Repeated IDNAC SLC 4009 IDNAC Repeater Simplex Fire Alarm Control Panel with IDNAC SLC (4100ES shown for reference) F ping — j IDNAC SLC 4009 IDNAC Repeater Extends Distance and Current of IDNAC SLC Iiui *wLIfôTiI1iTJiJ Class A Adapter 4009-9814: Required when extending a Class A loop or to provide a Class A local loop SLC output Operation provides short circuit isolation between input and output terminals for improved IDNAC SLC survivability Built-in battery Charger Power supply charges up to 12.7 Ah batteries for in cabinet mounting and up to 25 Ah batteries with model 4009-9801 external battery cabinet Available auxiliary output: A 200 mA, 29 VDC constant auxiliary output is available; operation is maintained during battery backup S4009-0004-5 6/2015 irnrrri Repeating IDNAC SLCs. Simplex fire alarm control panels with IDNAC SLC outputs provide individual address and control of TrueAlert and TrueAlert ES addressable notification appliances. When an IDNAC SLC reaches the current limit or the distance limit of the source IDNAC SLC, use of 4009 IDNAC Repeaters extends the IDNAC SLC with an additional 3 A of SLC current and up to 139 unit loads of additional supervisory capacity. With IDNAC SLCs, a constant 29 VDC source voltage is maintained in alarm, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. MM= Three wiring configurations are available to provide a variety of system solutions: Class B branch extension, Class A loop extension, and Class A riser to Class B branch extension or Class A loop output. I Y(IYIllJTiJJ Class B branch input wiring allows T-tapped connections to up to five (5) parallel connected 4009 IDNAC Repeaters. Each Repeater has on-board output terminal connections for up to four (4) output branch circuits, and additional branch circuits can be externally T-tapped as required. (Refer to diagram on page 3 for additional details.) Class A loop extensions use a single 4009 IDNAC Repeater to extend the current and distance of a single Class A loop allowing the loop distance to be doubled. The Repeater communicates and repeats bi-directionally allowing Class A loop operation to be maintained in the event of an open circuit. This wiring connection requires use of the 4009-9814 Class A adapter. (Refer to diagram on page 4 for additional details.) Class A Riser to Class B Branches or Class A Loops. For applications requiring a combination of wiring types, a Class A riser can drive up to five (5) 4009 IDNAC Repeaters with each Repeater capable of driving either single or multiple Class B branch output(s) or a Class A loop output. In this wiring application, the Repeater does not repeat in the Class A riser loop, it is connected as an appliance with Class A in/out wiring. To create a Class A loop output, the Repeater must be equipped with a 4009-9814 Class A Adapter. (Refer to diagram on page 5 for additional details.) Product Selection Model* Cabinet Color Description (4009-9601JBA) Platinum 4009 IDNAC Repeater with cabinet; provides a single 3 A IDNAC SLC output, 200 mA auxiliary 4009-9602(BA) Red power output, and battery charger; 120/240 VAC, 50/60 Hz input, auto-select * Add suffix BA to select 4009 IDNAC Repeaters assembled in the USA. Aftermarket Accessories (installed on-site, select per system requirements) Model I Description 4009-9814 Class A Adapter Module, mounts on repeater controller board; required for Class A output 2975-9813 Platinum semi-flush box trim Ii /i " (37 mm) wide, four corners and trim pieces for top, bottom, and sides; (will 2975-9812 Red semi-flush box trim need to be cut to fit 4009 IDNAC Repeater cabinet) External Accessories (select per system requirements) Model I Description Comments 4905-9929 1 Remote TrueAlert Communications Isolator I Refer to data sheet S4905-0001 for details 4009-9801 External Battery Cabinet for 25 Ah batteries 16 %" W x 13 ¼" H x 53/4' D (413 mm x 343 mm x 146 mm); refer to data sheet S2081-0006 for details Battery Selection (select battery size per system requirements; two batteries are required for 24 VDC operation) Model Description Model Description 2081-9272 6.2 Ah Battery, 12 VDC 2081-9275 18 Ah Battery, 12 VDC Requires 4009-9801 External Battery Cabinet 2081-9274 10 Ah Battery, 12 VDC 2081-9287 25 Ah Battery, 12 VDC 2081-9288 112.7 Ah Battery, 12 VDC 11 I S4009-0004-5 6/2015 Wiring Reference, Class B Input with Class B Branch Circuit Outputs IDNAC SLC input 4009 IDNAC Repeatei (5 maximum) Class B Branch Extensions IDNAC SLC output Class B IDNAC SIC Class B IDNAC SIC Class B wring can be - Sãuplex Fire Alarm Control Panel with IDNAC SIC (4IOOES shown for reference) Class B IDNAC SIC g Notes: I Up to five (5)4009 IDNAC Repeaters can be wired in parallel as shown on this dlagram IDNAC SIC comniirications can be repeated only once between the source and the addressable appliance. The 4009 IDNAC Repeater extends distance and current of the input IDNAC SIC; it requires one address and consumes four (4) unit loads. Class B IDNAC SIC tit PIIHII ~Rg Class B IDNAC SIC Each 4009 IDNAC Repeater has duplicate output teminals rated for two wires each, allowing upto foiz (4) Class B branch circuit T-taps to be made in the cth1e1 additional T4aps may be made in external wiring junction cabinets or boxes 1-4 PIRO -WL Class B IDNAC SIC Branch Circuits 17-tapped-Wirin 3 S4009-0004-5 6/2015 Wiring Reference, Class A Loop Extension Class A IDNAC SLC Loop with 4009 IDNAC Repeater Extending Loop Range and Power 4009 IDNAC Repeater Requires optional 4009-9814 Class A Adapter Module set for Loop mode <1- Class A loop secondary direction - - Class A loop primary direction Flag HI*F!JHII Class A loop secondary direction Simplex Fire Alarm Control Panel with IDNAC SLC; requires oplional Dual Class A IDNAC Isolator (DCAl), refer to individual panel documentation for details (4IOOES with EPS shown for reference) Notes: Only one 4009 IDNAC Repeater can be wired in a Class A loop. (IDNAC SLC communications can be repeated only once between the source and the addressable appliance.) The 4009 IDNAC Repeater extends distance and current of the Class A IDNAC SLC loop; it requires one address and consumes four (4) unit loads. Under normal operating conditions (no open circuit wiring), appliances I through 4 are powered by the Panel Power Supply and appliances 5 through 9 are powered from the 4009 IDNAC Repeater. Under open circuit conditions, an open circuit in the panel side of the primary path will result in the Panel Power Supply powering appliances 5 through 9 and the 4009 IDNAC Repeaterwill receive IDNAC SLC input from the return path and then power appliances 1 through 4, or as many as remain connected. S4009-0004-5 6/2015 Lwinng Reference, Class A Riser Input with Class A Loop and Class B Branch Outputs Simplex Fire Alarm Control Panel with IDNAC SLC; requires optional Dual Class A IDNAC Isolator (OCAI), refer to individual panel documentation for details (4I00ES with EPS shown for reference) Requires optional 4009-9814 Class AAdapter Module set for Branch Mode to create a local Class A loop circuit output Class A Loop Extension IDNAC SLC input Class A Loop rT IL LTJ =FIRN 4009 IDNAC Repeaters "--- 1- Class B Branch Extension 5L IDNAC SLC shown as a Class A Riser with each IDNAC Repeater wired in(out (not T-tapped); IN only t (2) are shown, maximum is five (5) Wring detail reference (repeaters - } are wired same as appliances) 4009 IDNAC Repeater Mounting and Module Placement Reference L_ Cabinet depth -ø ['4-1I8 (105 mm) Done; 5V (16usm)thdc I (277 E,q,esed cabinet dimension for sem14is1i mount r (25.4 mm), 1-8 (35 mm) with semi-lush him 0 \ - \\ (343 mm) Knockouts for screw or nail mounting holes ---------------------------------------- I I I I I S : 12(305mm) I I Battery location (dotted line) no conduit entry H,, or wiring in this area, 12.7 Ate maximum ! 0 / Opticx Semi-Flush Trim Kit -ø. Shaded Area is Non-power limited - 1-Y16 wkle (30mm). 8 (9.5 mm) thick Wall surce refeince for semi-flush mount 5 S4009-0004-5 6/2015 4009 IDNAC Repeater Specifications Input Ratings Voltage Range 120 VAC, 50/60 Hz, 01220/230/240 VAC, 50/60 Hz, +10%, -15%, auto-select Input Ratings 120 VAC Current 2.5A 220/230/240 VAC Current 1.25 A Panel IDNAC Appliances Auxiliary Load 70 mA 0.8 mA each Output current Standby Currents 24 VDC Requirements ___________________________________ is from battery) (voltage for Battery Calculations 4.5 A maximum with 3 A IDNAC SLC load 1.37 x output current Alarm Currents 96 mA and 200 mAAuxiliary output load (actual (voltage converter is on alarm current depends on connected and when in Alarm) activated appliances _and _devices) 17 VDC minimum IDNAC Input Ratings I address, 4 unit loads Output Ratings IDNAC SLC Output 3 A maximum @ 29 VDC for Special Application appliances Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances Each repeater uses four unit loads on the EPS it receives power from and supports up to 139 additional unit loads. Most appliances are I unit load; Multi-Tone appliances are 2 unit loads; Repeaters and Isolators are 4 unit loads. Refer to individual appliance IDNAC Repeater Loading and SLC and device specifications for unit load requirements and rated SLC loading Address Usage specifications. Each repeater uses one IDNAC SLC device address - the IDNAC Repeater does not increase the IDNAC channel device address capacity. Refer to the Host IDNAC SLC specifications for the device address capacity specifications on the IDNAC channel. Current 200 mA maximum Auxiliary Output Voltage g 29 VDC nominal with AC present or when Repeater is on battery standby and in Alarm 24 VDC nominal when on battery standby and not in Alarm IDNAC SLC Wiring Specifications (refer to installation instructions for more information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with "1-Taps"_ for class B_wiring 10,000 ft (3048 m) Maximum wire length to any appliance 4000 ft (1219 m) Wiring Connections Terminal blocks for 18 to 12 AWG Repeater Status Indicators Green AC Power LED On with AC present, off during brownout or no AC condition Red Communications LED (COMM) Blinks when Repeater is communicating with the host control panel Yellow System Status LEDs 4 LEDs provide up to 16 different trouble status indications; an on-board trouble scroll button allows review should multiple troubles occur 4009-9814 Class A Adapter Module Option (required for Class A loop extension or for Class A output) 3 A maximum @ 29 VDC for Special Application appliances IDNAC SLC Output Voltage Two connections, Port A and Port B, function varies by application (loop extension or local loop), Port A and Port B are isolated from each other Status LEDs Two yellow trouble LED indicators, one per Port Environmental and Technical Publications Reference Operating Temperature 32° to 120° F (0° to 49° C) Operating Humidity Range Up to 93% RH at 90° F (32° C) Installation 4009 IDNAC Repeater 579-1019 Instructions Class A Adapter Module 579-1080 TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Tyco Fire Protection Products• Westminster, MA • 01441-0001 - USA S4009-0004-5 6/2015 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0375 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4009-9601, 4009-9601 BA, 4009-9602 and 4009-9602 BA IDNAC repeaters. Model 4009-9814 Class A Adapter card. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 120V/240V INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an accessory for use with listee's separately listed compatible fire alarm control units. Authority having jurisdiction should be consulted prior to installation. 04-23-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division £®Simplex lrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved; Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via IDNetTM or MAPNET il®, 2-wire communicationst Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet/MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listlig 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster, Duct Sensor Housing, Front and Bottom View 0 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station irnrrrti Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. lTT ii iiiii .i.i .ii r*iT1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Please not that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and lONet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; D383,407; 0388,352; D392,573; 4,796,025. S4098-0030-5 3/2007 I]trTyIIrnaJ Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. IlMiiiI!fTli7i11W. TflIItui*i . Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control I u11iI(.]&sIS U I tor UIN, urr, or overriue Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4020, 4100, 4100U, and 4120. Also 2120 CDT if configured either IDNet or MAPNET II communications (no relay output) for MAPNET II, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 Relay output is for up to 15 total 4098-9843 end-of-line resistor harness; includes one 4098-9843 relay Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, 4098-9755 Test Station with keyswitch and red LED status indicator 4098-9756 3" H x 2" W x 2" D (turning switch to "TEST" initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; connect (1 m) of device being up to 15 wiring is 18 AWG (0.82 mm2 ) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 k, 1/2W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2" (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 1 2" (51 mm) longer than duct width S4098-0030-5 3/2007 ZMERM? MR NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. II 11-3/8" (289 mrn)-J I Exhaust tube access hole 1 4098-9714 Smoke sensor, mounted in special interface base (supplied) -i Metal plate with dual holes for 3/4 (19 mm) conduit, plug supplied for unused hole j 30001100 •© I o o ono 00 ow LED, relay control trouble indicator (4098-9756 only) 0 Red sensorl status LEDJ Side of duct}_... © gtermiii) netic test area) \ ---4 I sensor Mount as shown (preferred) o area ].......... with electronics area located to the LEFT or UP ONLY 3-3/8" (86 mm) (21 mm) 13/16" —.—j Test ports (2) provided Sampling tube, ordered for measung airflow separately per duct width and for aerosol injection Exhaust tube (supplied) Duct wall 6-3/4 (171 mm) access hole screws End View with Duct and Tubes ) J Duct housing 7 [18 Round duct outline (minimum diameter ' —I [haust tube 8" Square duct outline1 (minimum width) with holes f (template is - - •j I' - Sampling tub: keyed for proper acing into airflow hole alignme provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 —T : vw (38 mm) 1-3/16' (30 mm) 3 S4098-0030-5 3/2007 I.irri Exhaust Sensor 7 Damper OK Exhaust -LIIII JJ _Return Air Do not locate sensor here Return air damper Fresh Supply air Air Filter " Sensor Do not locate sensor here bank OK Bend or obstruction Return 6 Duct Duct widths ~p L :.— minimum -i widths minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. Specifications General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black base with clear cover Remote Status/Alarm LED 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation I IDNet or MAPNET II communications, auto-select, one address per housing; Data Communications provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 115 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 kI), 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current 115 mA @24 VDC, up to 15 maximum per relay control output Relay Contacts 7 A at 0.35 PF @28 VDC & 120 VAC 250,iA@ SVDC Location Distance I 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device I being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueAlarm, JDNet, and MAPNETJJ are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster• Westminster, MA • 01441-0001 • USA S4098-0030-5 3/2007 .Simplex www.tycosafetyproducts-usa-wm.com © 2007 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9755, *40989755Tsp *40989755TTp 4098-9756, *4098..97561sp *4098.9756TTp 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/min INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID cASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexlOo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators for use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division £L5implEx UL, ULC, CSFM Listed; FM Approved* I11!M_ Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 l'/16" / square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 I'i*i.i F1tti1 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. IM. I;f1 Model Description d90-901) 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 I For semi-flush I Trim plate, galvanized I mounted box I steel, with LED viewing For surface window; includes 4090-9802 mounted box mounting screws 4090-9813 I Adapter plate to fit 4 11Ae" (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listinç 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM jo !Ifl ! II (i 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) cific.itie I I Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type I Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings - Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4WHx4"Wx1 %"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © 11 F © © Add supplied label wARmr I AvERlissacirl cover on-site if control Em MI UK WEIN ling IAVER'nSSaENT:an U MR Im MR 4-9/16" 120 or 240 VAC 4-5/16 (116 mm) (109mm) Light pipe for LED viewing © © © © 4-9/16" (116 mm) II 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. fl.SiMpirX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4090-0015-1 11/2014 www.simp!ex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *4090.9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt i This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 0 SimplEx TrueAlert ES Addressable Notification Appliances UL, ULC, CSFM Listed; FM Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Approved Description Ceiling Mount Addressable Visible (VIO) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC Signaling Line circuit (SLc). V/C notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process. Features Individually addressed Visible Only (1/0) notification appliances Multi-candela LED strobe available in low (15, 30 75 and 110 cd) and high (110, 135 and 185 cd) range candela models. Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators. Advanced addressable notification controlled by IDNACSLCs. IDNAC SLCs provide regulated 29 VDC allowing horns to operate with lower current Electrical test point access by removing the cover Strobe intensity can be programmed from the control panel or the device Wiring supervision to each appliance allows T-tapped connections for Class B circuits to simplify wiring (class A circuits require in/out wiring) Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID, custom label, type, and candela setting Magnet test diagnostics assist checkout and testing of appliances and wiring compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Synchronized strobe operation on its IDNAC channel. LED Indicator and Magnet Test feature: Indicator LED indicates magnet test acknowledgment, 3 digit IDNAC address, and candela rating Indicator LED can be configured to blink every polling cycle to indicate appliance supervision When the controller is in diagnostic mode, the magnet test pulses the Indicator LED to indicate appliance address and can be set to also briefly flash the strobe LEDs Mechanical design features Rugged, high impact, flame retardant thermoplastic housing in red and white colors Various covers and lettering options available - Red with white letters or white with red letters covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts on 4" square or single gang USA electrical boxes. Adapter plate required for mounting on single gang electrical boxes. Optional wire guards Weatherproof back boxes are required for surface mounting. Figure 1: Indoor Ceiling Mount Strobe Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BocA, ICBO, or SBccI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. TrueAlert ES Diagnostics Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Magnet Test In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test lDcs, NAcs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. *Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. AC49vOC-0001 Rev. 12 3/2019 Appliance with cover (front) Appliance (rear) Wiring terminals for strobe connections accept #12-18 AWG wires' Simplex Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Installation Reference Address dip switch Set device address before fixing cover in place. Candela flag setting Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set the flag to the desired candela rating. Use slotted screwdriver here to remove cover IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire Circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When class B wiring is used, wiring can be T-tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1: ceiling Mount Addressable Visual Only V/O Appliances Model* Lens color Description Installation Instructions 49VO-APPt 49vO-ApPLc-BA ______ .... -- Clear 49V0H-APPLC-BA VO appliance only. Select cover separately. 579-1227 49V0H-APPLcA Amber 49V0H-APPLCB Blue 49vOH-APPLcG Green -1 7 280 49V0H-APPLcR Red Table 2: Surface/WP back boxes Model Color Description Installation instructions 49WPBB-VOCR Red SurfacetvvP back box in red 79-1270 49WP88-VOCW White Surface/WP back box in white Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. - Page 2 AC49VOC-0001 Rev. 123/2019 Simplex Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Table 3: Adapter plates Model Description Installation Instructions 49V0-APCS 10 Ceiling Mount Adapter Plate. Required for mounting on a single gang electrical box. Table 4: V/O Covers (Required when ordering APPLC models) Model* 49vOC-CRALT 49V0C-CRBF Color Black Wording ALERT FEU/FIRE 49V0C-CRFEU FEU 49V0C-CRF Red . FIRE Simplex logo only 49V0C-CRBAA 49V0C-CRBCF LL(/ALERT */FIRE 49V0C-CRBAF -- 49V0C-CK j.-/FlRE Blank 49V0C-CWALT White ALERT 49V0C-CWBF FEU/FIRE 49V0C-CWFEU FEU FIRE Simplex logo only 49V0C-CWF 49V0C-CWBAA 49V0C-CWBCF LL)/ALERT */FIRE 49V0C-CWBAF j.-/FlRE Table 5: Wire Guards Model Description 49WG-VOCR VO Ceiling Mount Red Wire Guard 49WGBB-VOCR VO Ceiling Mount Wire Guard Back Box Note: * (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6: Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage iDesign Reference - 4100ES with EPS+ or EPS Power Supply S4100-0100 i 4009 IDNACRepeater - ................- ------------------------- ... ............. . 94009-0004 .IDNAC SLC S4100-0034 29 VDC 23 VDC (regulated) (with 6 VDC drop) 4100ES Flex 35, 50, and 100 Amplifiers - ---- Page 3 AC49VOC-0001 Rev. 12 3/2019 Simplex Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 TrueAlert ES V/0 LEGACY Compatibility Reference Table 7: Compatibility Reference Compatible Controller Data Sheet Reference Appliance Voltage Controller Output Available Strobe Intensity Minimum 4100ESor4100Uwith I S4100-0031 TrueAlert Power Supply 4009 TPS, Remote TrueAlert 17 VDC Power Supply _ S4100-0037 j TrueAlert Addressable SLC 15, 30, 75, and 110 cd 17 VDC TrueAlert Addressable Controller (40091) S4009 0003 I Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 117 VDC to 31 VDC, Special Application Candela Setting 15 cd 30 cd 75 cd 110 cd 17 VDC RMS Current Ratings, with horn on continuousat high setting, 173 m 14 m 210 mA ~269 mA use when connected to TrueAlertAddressable SLCs per above * For connection to legacy fire panel models Simplex 40091 and 4100/TPS. High candela (49V0H) appliances are not compatible with Simplex models 4009T and TPS, see the fire panel compatibility charts. Ceiling Mount V/0 Specifications Table 8: Specifications Specification Rating Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two Connections wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Table 9: Percentage of rated light output at room temperature Angle -- On-Axis ............................ Vertical, Below Axis Horizontal, Left/Right of Axis ___ 450 900 :450 900 UL required output 100% 45% 25% 45% 25% Typical output 327% 134% 83% 129% 47% Table 10: Appliance Specifications © 2019 Johnson controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). AC49VOC-0001 Rev. 12 3/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0 FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0373 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Model 49AVTrue Alert ES addressable horn/strobes with suffixes WRF, WRF-BA, W\NF, \MNF-BA, *wRS WRS-BA, WVS-BA, *WRQ WRQ-BA and APPLW. Model 49AVTrue Alert ES addressable horn/strobe covers with suffixes WRFIREWVFlRE, WRS,WtNS, WRALT, WWALT, WRFEU, \MNFEU, WRBLNG, and WNBLNG. Model 49VOTrue Alert ES addressable strobes with suffixes WRF, WRF-BA, WvVF, WWF-BA, *wRS WRS-BA, *\5 WNS-BA, *WRA, WRA-BA, *WA WWA-BA, *\fQ *\fQ ,WRQ-BA, and *\fQ Model 49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, WNFIRE, WRS, M.NS, WRALT, WNALT, WRFEU, WNFEU, WRBLNG, and WNBLNG. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 17-31 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a wall mount horn/strobe or strobe for indoor use only. Models require the use of the 4009-9401 lrueAlert NAC extender (CSFM Listing No. 7300-0026:214) or 4100-5120, -5121 -5122 True Alert Power Supples*or 4100-5311, -5313, -5325, 53-27 Extended Power Supplies (CSFM Listing No. 7165-0026:251) *or 4010-9601, -9602, -9603, -9604, -9606, 9701, -9702, 9722 Control Units (CSFM No. 7165-0026:369) or 4007-9201, -9202 Control Units (CSFM No. 7165-0026:378). Refer to listee's Installation Instruction Manual for details. *Rev 09-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SimplEx TrueAlert Addressable Notification Appliances UL, ULC Listed; FM Approved Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Introduction Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from the Simplex Fire Alarm control Unit IDNAC Signaling Line circuit (SLC). Audio is supplied from a separate compatible Simplex Fire Alarm control Unit audio NAc. Wiring supervision is electronically monitored allowing audio and IDNAC wiring to be I-tapped for class B wiring, reducing wiring costs and wiring distances. Installation on standard 4 inch square 2 1/8 inch deep USA electrical boxes for flush installations (provided by others) or surfaceNVP backboxes (order below) for surface or WP installations. Appliances are available in 400-4000 Hz and 200- 10000 Hz high fidelity models. Separate appliance and cover selection greatly simplifies the ordering and installation process. Model numbers ending in -BA are assembled in the USA. separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-0001. Figure 1: ceiling Mount Addressable SpeakerNisible Notification Appliance Ceiling Mount Addressable Speaker Product Selection Table 1: ceiling Mount Addressable Speaker SN Appliances Model Description Installation Instructions 9SV-AP SN appliance only. Select cover and surface/WP box (if 579-1203 49Sv-ApPLc-BA required) separately. Table 2: High Fidelity Appliances Model Description Installation instructions 49HFv-APPLc High Fidelity SN appliance only. Select cover and 5791203 49HFv-AppLc-BA surface/WP box (if required) separately. Table 3: High Candela Appliances Model Description installation instructions - High Candela SN appliance 49SvH-AppLc-BA only. Select cover and 49SVH-APPLO weatherproof box (if required) 579-1203 separately. Table 4: High Fidelity High Candela Appliances Description instructions SN Appliance Only. Select -BA lcover and surface/WP box (if i,required) separately. Appliance with amber colored 49H FVH-APLCA-BA 579-1203 liens. Select cover and surface/ wp box (if required) separately. IHigh Fidelity High Candela 5/ IV Appliance with blue colored 49HFvH-ApLcB-BA lens. Select cover and surface! WP box (if required) separately. Tables: SN Covers (Required when ordering APPLC models) SKU Wording 49Svc-cRALT Red ALERT 49SVC-CWALI White 4§M-C' Red 49SVC-CWBA ---....-.--.. j,'-!FlRE 49Svc-cRBc Red '' /FIRE ALARM 49SVC-CWBC White 49Svc-CRBF Red EU/FIRE 49Svc-cWBF White 49SVC-CRFEU Red FEU 49SVC-CWFEU White 49Svc-cRFlRE Red FIRE 495vc-cwFlRE White 49SVC-CRS Red Simplex logo only 495VC-CWS White 49SvC-cK Black INo logo or lettering * Additional listings may be applicable; contact your local simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. S49Svc-0001 Rev. 7 10/2018 5impIEx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Weatherproof Product Selection Table 6: Weatherproof Ceiling Mount Addressable SN Appliances KU Description Installation instructions gSVH-APPLC-O SN Appliance Only. Select cover and surface/WP 1579-1241 9SVH-APPLC-CO (Canada only) box separately Table 7: SN Covers (Required when ordering APPLC-O models) SKU iColor Wording 49SVC-CRALT-0 .---JRed --.-. I ALERT 49SVC-CWALT-0 White 49SVC-CRBA-0 IRed ---.------ ---- lWhite /Fl RE 49sVC-CRBC-O Red )A/FIRE ALARM 49SVC-CWBC-0 White 49SVC-CRBF-0 Red 49SVC-CW6F-5 White FEU/FIRE 49SVC-CRFEU-0 iRed - 495VC-CWFEU-0 White FEU 49SVC-CRFIRE-0 49SVC-CWFIRE-O Red -- White FIRE 49SVC-CRS-0 Fed Simplex logo only 495VC-CWS-O lWhite 49SVC-CK-0 Black Table 8: Surface/WP Back Boxes SKU Color Description Installation instructions 49WPBB-SVCR iRed Surface/WP back box in Red _____ 579-1240 49WPBB-SVCW lwhite Surface/WP back box in White Table 9: Wire Guards and Wire Guard Back Boxes SKU Description 49WGBB-SVCR-0 - 49WG-SWCR Wire Guard Back Box, Ceiling, Red, WP Wire Guard, Ceiling, Red Ceiling Mount SN Specifications Table 10: Appliance General Specifications Specification Rating Dimensions 8 1/8" H x 7 1/8" W x 3" D (206mm x 180mm x 76mm) Environmental 132o to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. Table 11: Speaker Audio Specifications pecification Rating nput voltage 125 or 70.7 Vrms lower 11,4,½,1, and 2W ___ i:400 to 4000 Hz ..SN requency Response H/F General Signaling = 125 to 12kHz Table 12: Speaker Output Ratings Wattage Tap 1/4 W 1/2 W 11W j2W Model •SN H/F $N H/F ,SN H/F SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 179 176 183 80 86* 84 189* 87* Anechoic Chamber Test, per ULC-5541 (dBA)* 179 78 183 182 86* 85* 189* 188- * Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per LJLC-5541 Anechoic Chamber Testing) Attenuation 1-3-n J70° Angle Attenuation Angle -6 dB 80° Page 2 S49SVC0001 Rev. 7 10/2018 SimpIx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Table 13: Percentage of rated light On-Axis Vertical, Below Axis Horizontal, Left/Right of Axis Angle 0° 45° 900 450 900 UL required output 1Th0% 25% 1f25% Typical output 1327% 134% 83% 129% Table 14: IDNAC SLC Specifications Specification Typical Operating Voltage Range 123 VDC to 30 VDC, Special Application Appliance voltage design reference 23VDC (with 6VDC drop) Supervisory Requirements 1 unit load (= 0.8 mA control unit current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max 127 SN appliances per IDNAC channel Maximum of 127 addresses per SLC, 139 unit loads. See device and IDNAC SLC Loading compatible Fire control Unit Installation Instructions for circuit current load limits. UTP, unshielded twisted pair recommended IDNAC SLC Wiring Specifications (refer to control unit installation Maximum wire length allowed with "T-Taps" for Class B wiring per SLC = instructions for more information) 10,0003 4m aximum wire length to any appliance = 4000 ft (1219 m). This can be [doubledto 8000ft (2438m) by using a 4009 IDNAC Repeater. Table IS: Current consumption** Candela Setting 15 c 130 c 75 c 11cd j5cd 185 c 49SV and 49HFV 59 mA 182mA 145 mA 193 mA N/A N/A models 49SVH and 49HH N/A N/A 259 mA mA models N/A 1281 325 mA Weatherproof SV N/A N/A 320 mA 360 mA N/A 400 mA appliances ** Measured at 23VDC on IDNAC Addressable SLC Speakers are for connection to compatible fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. Table 16: Equipment Compatibility References Compatible Equipment Data Sheet Reference 4100ES with EPS+ or EPS Power Supply 54100-0100 4009 IDNAC Repeater 54009-0004 4100ES Flex 35 and 50 Watt Amplifiers -- 4100ES 100 Watt Amplifiers 54100-0034 4100ES Constant Supervision and Signal Cards Page 3 S49SVC-0001 Rev. 7 10/2018 Mount to 4"X 4"X 2-1/8" Appliance (rear) electrical box using 8-32 screws - Note: Ceiling mount only la. © 5impIEx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Ceiling Mount SN Installation Reference Appliance with cover (front) Magnet test location G 0 indicated by area that o is not textured (0— 93 CO 10-000000 0 - I 000000000%00 00 0 00 00.0.0.00000.00%,0100 00 0 Appliance test points, I 1 0000 0000000 I audio circuit power taps, , / and address dip switch J 000, 00*0 Set audio circuit power taps and .' \0cfq0Q,0/ device address before fixing 00 00 00 cover inplace. Candela flag setting 1 1 1 tI1Wiring strobe terminals WNW Co. Set flag to FACP to control aker_( accept wires candela rating from an FACP : providing IDNAC notification. To set candela manually, set ,' 110 - the flag to the desired : 75 30 - canA ea rang. s Use slotted screwdriver cp , here to remove cover. Figure 2: Installation reference © 2018-Johnson controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NEPA). 549SV-0001 Rev. 7 10/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models: 49SV-APPLC,49HFV-APPLC,495V-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,495V-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49SVAPPLW0 *49SVAPPLW.0..BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com Contractor's License Detail for License # 986047 JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2021 This license is current and active. All information below should be reviewed. Classifications- CIO - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond of Qualifying Individual j This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/20180 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC313943 Effective Date: 10/01/2018 Expire Date: 10/01/2020 Workers' Compensation History Personnel listed on this license (current or disassociated) are listed on other licenses. I 10/11/2019 REV.#: 0 PROJECT #: 480-