Loading...
HomeMy WebLinkAbout2111 PALOMAR AIRPORT RD; ; AS140002; Permit12/16/21, 3:55 PM AS140002 Permit Data City of Carlsbad Sprinkler Permit 2111 PALOMAR Job Address: AIRPORT RD Permit Type: SPRINK Parcel No: 2130701400 Lot #: 0 Permit No: AS 140002 Status: ISSUED Applied 1/7/2014 Approved: 1/9/2014 Reference No.: Issued: 1/9/2014 PC #: Inspector: Project Title: HANSEN TI—RELOCATE EXISTING RECESSED STANDARD RESPONSE, STANDARD SPRAY RENDENT AT LOCATION SHOWN ON PLANS Applicant: TOTAL FIRE PROTECTION, INC. STE. 244 1611-AS. MELROSE DR. VISTA, CA 760-525-4329 Owner: REALTY ASSOCIATES FUND VII L P C/O TA ASSOCIATES REALTY 1301 DOVE ST #860 NEWPORT BEACH CA Fees ($) lAdd'IFees ($) Total ($)r Balance f 0 * 268 0 1/1 As ioo CONTRACTOR'S MATERIAL & TEST CERTIFICATE FOR A BOVEGROUND PIPING PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owners representative. All defects shall be corrected and system left in service before contractors personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME Date 1/21/14 Hansen PROPERTY ADDRESS 2111 PALOMAR AIRPORT ROAD. SUITE 200 PLANS ACCEPTED BY APPROVING AUTHORITY(S) NAMES Carlsbad Fire Department ADDRESS INSTALLATION CONFORMS TO ACCEPTED PLANS YES EQUIPMENT USED IS APPROVED D YES IF NO, EXPLAIN DEVIATIONS 0 NO 0 NO INSTRUCTIONS HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO LOCATION OF CONTROL VALVES AND CARE AND MAINTENANCE OF THIS NEW EQUIPMENT? IF NO, EXPLAIN 0 YES 0 NO HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: SYSTEM COMPONENTS INSTRUCTIONS 0 YES CARE AND MAINTENANCE INSTRUCTIONS 0 YES NFPA25 OYES 0 NO 0 NO 0 NO LOCATION OF SYSTEM SUPPLIES BUILDING: MAKE MODEL YEAR OF MANUFACTURE K FACTOR QUANTITY TEMPERATURE RATING co SPRINKLERS PIPE AND FITTINGS Type of Pipe: Schd. 40 and Lightwall Type of Fittings: Cast iron 125# and Grooved ALARM VALVE OR FLOW INDICATOR ALARM DEVICE MAXIMUM TIME TO OPERATE THRU TEST CONNECTION TYPE MAKE MODEL MIN. SEC. DRY PIPE OPERATING TEST DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. TIME TO TRIP THRU TEST CONNECTION* WATER PRESSURE AIR PRESSURE TRIP POINT AIR PRESSURE TIME WATER REACHED TEST OUTLE ALARM OPERATED PROPERLY MIN. SEC. PSI PSI PSI MIN. SEC. I YES NO Without Q.O.D. 0 0 With Q.O.D. 0 0 IF NO, EXPLAIN: MEASURED FROM TIME INSPECTOR'S TEST CONNECTION OPENED. (OVER) OPERATION 0 PNEUMATIC 0 ELECTRIC 0 HYDRAULIC PIPING SUPERVISED 0 YES 0 NO DETECTING MEDIA SUPERVISED 0 YES 0 NO DOES VALVE OPERATE FROM THE MANUAL TRIP AND/OR REMOTE CONTROL STATIONS 0 YES 0 NO IS THERE AN ACCESSIBLE FACILITY IN EACH CIRCUIT FOR TESTING IF NO, EXPLAIN DELUGE & PREACTION 0 YES 0 NO VALVES DOES EACH CIRCUIT OPERATE DOES EACH CIRCUIT OPERATE MAXIMUM TIME TO MAKE MODEL SUPERVISION LOSS ALARM? VALVE RELEASE? OPERATE RELEASE YES NO YES NO MIN. SEC. 0 0 0 0 HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bars) for two hours or 50 psi (3.4 bars) above static pressure in excess of 150 psi TEST (10.2 bars) for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. DESCRIPTION PNEUMATIC: Establish 40 psi (2.7 bars) air pressure and measure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop which shall not exceed 1-1/2 psi (0.1 bars) in 24 hours. ALL PIPING HYDROSTATICALLY TESTED AT 0 PSI FOR 2_ HRS. IF NO, STATE REASON: DRY PIPING PNEUMATICALLY TESTED 0 YES 0 NO EQUIPMENT OPERATES PROPERLY []YES 0 NO DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT ADDITIVES AND CORROSIVE CHEMICALS, SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR TESTING SYSTEMS OR STOPPING LEAKS? TESTS ZYES 0 NO DRAIN READING OF GAGE LOCATED NEAR WATER SUPPLY TEST RESIDUAL PRESSURE WITH VALVE IN TEST TEST I CONNECTION: PSI I CONNECTION OPEN WIDE PSI UNDERGROUND MAIN AND LEAD IN CONNECTIONS TO SYSTEM RISERS FLUSHED BEFORE CONNECTION MADE TO SPRINKLER PIPING OTHER EXPLAIN VERIFIED BY COPY OF THE U FORM NO. 85B 0 YES 0 NO FLUSHED BY INSTALLER OF UNDER- GROUND SPRINKLER PIPING []YES 0 NO BLANK NUMBER USED LOCATIONS: NUMBER REMOVED TESTING 0 GASKETS WELDED PIPING 0 YES 0 NO IF YES... DO YOU CERTIFY AS THE SPRINKLER CONTRACTOR THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS DI0.9, LEVEL AR-3? DYES 0 NO DO YOU CERTIFY THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN WELDING COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST AWS DI0.9, LEVEL AR-3? DYES 0 NO DO YOU CERTIFY THAT WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED? 0 YES 0 NO CUTOUTS DO YOU CERTIFY THAT YOU HAVE A CONTROL FEATURE TO ENSURE THAT ALL (DISCS) CUTOUTS (DISCS) ARE RETRIEVED? YES 0 NO HYDRAULIC NAME PLATE PROVIDED IF NO, EXPLAIN: DATA NAMEPLATE 0 YES 0 NO DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: REMARKS NAME OF SPRINKLER CONTRACTOR: TESTS WITNESSED BY FOR PROPERTY OWNER (SIGNED) TITLE DATE SIGNATURES I I F(nSPRINKLE CONT CT SIGNED) TITLE _. DAT i 'A FOA 110CAL FIRE MARSHAL (SIGNED) TITLE DATE FOR RESPONSIBLE MANAGING EMPLOYEE (SIGNED) TITLE DATE ADDITIONAL EXPLANATION AND NOTES (BACK)