Loading...
HomeMy WebLinkAbout2519 PALOMAR AIRPORT RD; ; FA130070; Permit12/16/21, 4:03 PM FA130070 Permit Data City of Carlsbad Fire Alarm Permit 2519 PALOMAR Job Address: AIRPORT RD Permit Type: FALARM Parcel No: 2130201800 Lot #: 0 Permit No: FA130070 Status: PENDING Applied 10/21/2013 Approved: Reference No.: Issued: PC #: Inspector: Project Title: CYO PIZZA PCR13147 PROVIDE FIRE ALARMS FOR THE IMPROVED AREA AS SHOWN ON PLANS. NEW DEVICES SHALL BE CONNECTED TO THE EXISTING FIRE ALARM SYSTEM. OCCUPANCY TYPE A-2 RESTAURANT AREA 2,123 SF, FULLY SPRINKLED Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: COUNTY OF SAN DIEGO PUBLIC AGENCY Fees ($) Add Fees Total ($) Balance ($) 286 0 286 0 1/1 WEUISES FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS CYO PIZZA TENANT IMPROVEMENT 2519 Palomar Airport Road Suite 5-101 Carlsbad, CA FIRE ALARM SYSTEM MATERIAL DATA SHEETS FA130070 / DN-6061 6:B NOTI Fl ER Intelligent Modules ® by Honeywell General The Honeywell HFS(A) intelligent module products are designed to meet a wide range of applications. Each module is rigorously designed and tested for electromag- netic compatibility and environmental reliability. Modules are addressed with easy-to-use rotary code switches. HFS-MM(A) Mini Monitor Modules provide an interface to con- tact devices, such as waterflow switches, sprinkler valves, or pull stations. They are capable of Style B supervised wiring to the monitored device. In addition to transmitting the super- vised state of the monitored device (normal, open, or short), the full analog supervision measurement is sent back to the panel. This allows detection of impedance changes in the supervised loop to the monitored device. The HFS-MR(A) Relay Module contains two isolated sets of Form C contacts, which operate as a double-pole, double- throw switch. The module allows the control panel to switch these contacts on command. It mounts in a standard 4 in. x 4 in. x 21/8 in. junction box. Wiring terminals are easily accessi- ble for troubleshooting. Features UL and ETL listed to UL 864 ULC and ETL (Canada) listed to ULC S527 Analog communications Rotary address switches Low standby current Mounts in standard 4-in, junction box SEMS screws for easing wiring (HFS-MR(A) only) Panel controlled status LED (HFS-MR(A) only) Specifications GENERAL SPECIFICATIONS Operating Voltage: 15 to 32 VDC Communication Line Loop Impedance: 40 Ohm. max. Temperature Range: 32°F to 120°F (0° to 49°C) Relative Humidity: 10% to 93% noncondensing Shipping Weight: — HFS-MM(A): 1.2 oz (37 g) - HFS-MR(A): 6.3 oz (196 g) Dimensions: — HFS-MM(A): 2.7 in W x 1.7 in H x 0.5 in D — HFS-MR(A): 4.25 in W x 4.65 in H x 1.1 in D HFS-MM(A) ELECTRICAL SPECIFICATIONS Standby Current: 400 pA max @ 24 VDC (one communica- tion every 5 sec. with 47k EOL); 600 pA max @ 24 VDC (one communication every 5 sec. with IDC shorted) End-of-Line Resistance: 47 kOhm (included) HFS-MR(A) ELECTRICAL SPECIFICATIONS Standby Current: 300 pA max @ 24 VDC (one communica- tion every 5 sec. with LED enabled) a HFS-MM(A) HFS-MR(A) LED Current: 5.5 mA (with LED latched on) Relay Contact Ratings: 2.0 A @ 30 VDC resistive 0.3 A © 125 VAC inductive (PF=.35) Ordering Information HFS-MM(A): Mini Monitor Module HFS-MR(A): Relay Module Note: Use "A" versions for Canadian applications. Agency Listings UL/ULC Listed: S24843 ETL (US): 3196115CH1-001 ETL (Canada): 3196115CH1-002 CSFM: 7300-1130:278 DN-60616:B•06/15/2010— Page 1 of 2 16 NOTIFIER® and System Sensor® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I So ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. ENGINE(lN&MRNUFAC1URINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203)484-7161, FAX: (203)484-7118. www.notifier.com Page 2 of 2— DN-60616:13 • 06/15/2010 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION r. OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1130:0278 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Honeywell International lnc.95 East Algonquin Road, Building D, Des Plaines, IL 60017 Contact: Deo Supanavongs (847) 391-3223 Email: deo.supanavongs@honeywell.com DESIGN: Models HFS-MM Monitor Module and HFS-MR Relay Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Primary operating supply: HFS-MM 15-32 VDC, 600 uA HFS-MR 15-32 VDC, 6.5 mA INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as monitor module and relay module accessories for use with listee's separately listed compatible fire alarm control units. A 01-28-2010 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V%C operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division Nflormp EHUERFRnEl FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS CYO PIZZA TENANT IMPROVEMENT 2519 Palomar Airport Road Suite 5-101 Carlsbad, CA FIRE ALARM SYSTEM MATERIAL DATA SHEETS FA130070 HFS-MM(A) HFS-MR(A) DN-60616:B Intelligent Fl ER Modules ® by Honeywell - . I General The Honeywell HFS(A) intelligent module products are designed to meet a wide range of applications. Each module is rigorously designed and tested for electromag- netic compatibility and environmental reliability. Modules are addressed with easy-to-use rotary code switches. HFS-MM(A) Mini Monitor Modules provide an interface to con- tact devices, such as waterflow switches, sprinkler valves, or pull stations. They are capable of Style B supervised wiring to the monitored device. In addition to transmitting the super- vised state of the monitored device (normal, open, or short), the full analog supervision measurement is sent back to the panel. This allows detection of impedance changes in the supervised loop to the monitored device. The HFS-MR(A) Relay Module contains two isolated sets of Form C contacts, which operate as a double-pole, double- throw switch. The module allows the control panel to switch these contacts on command. It mounts in a standard 4 in. x 4 in. x 21/8 in. junction box. Wiring terminals are easily accessi- ble for troubleshooting. Features UL and ETL listed to UL 864 ULC and ETL (Canada) listed to ULC S527 Analog communications Rotary address switches Low standby current Mounts in standard 4-in. junction box SEMS screws for easing wiring (HFS-MR(A) only) Panel controlled status LED (HFS-MR(A) only) Specifications GENERAL SPECIFICATIONS Operating Voltage: 15 to 32 VDC Communication Line Loop Impedance: 40 Ohm. max. Temperature Range: 32°F to 120°F (0° to 49°C) Relative Humidity: 10% to 93% noncondensing Shipping Weight: - HFS-MM(A): 1.2 oz (37 g) - HFS-MR(A): 6.3 oz (196 g) Dimensions: - HFS-MM(A): 2.7 in W x 1.7 in H x 0.5 in D - HFS-MR(A): 4.25 in W x 4.65 in H x 1.1 in D HFS-MM(A) ELECTRICAL SPECIFICATIONS Standby Current: 400 .IA max @ 24 VDC (one communica- tion every 5 sec. with 47k EOL); 600 iiA max @ 24 VDC (one communication every 5 sec. with IDC shorted) End-of-Line Resistance: 47 kOhm (included) LED Current: 5.5 mA (with LED latched on) Relay Contact Ratings: 2.0 A @ 30 VDC resistive 0.3 A @ 125 VAC inductive (PF=.35) Ordering Information HFS-MM(A): Mini Monitor Module HFS-MR(A): Relay Module Note: Use "A" versions for Canadian applications. Agency Listings ULJULC Listed: S24843 ETL (US): 3196115CH1-001 ETL (Canada): 3196115CH1-002 CSFM: 7300-1130:278 HFS-MR(A) ELECTRICAL SPECIFICATIONS Standby Current: 300 .tA max @ 24 VDC (one communica- tion every 5 sec. with LED enabled) DN-60616:B.06/15/2010—Page 1 0t2 NOTIFIER® and System Sensol® are registered trademarks of Honeywell International Inc. ©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. --- This document is not intended to be used for installation purposes. ' so 9001 We try to keep our product information up-to-date and accurate. VVT dl We cannot cover all specific applications or anticipate all requirements. H®IN(ERtNC & MANUFACTURINS All specifications are subject to change without notice. DUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2— DN-60616:13 • 06/15/2010 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 4 LISTING SERVICE LISTING No. 7300-1130:0278 Page 1 of 1 CATEGORY: 7300-- FIRE ALARM CONTROL UNITACCESSORIES/MISC. DEVICES LISTEE: Honeywell International Inc.95 East Algonquin Road, Building D, Des Plaines, IL 60017 Contact: Deo Supanavongs (847) 391-3223 Email: deo.supanavongs©honeywell.com DESIGN: Models HFS-MM Monitor Module and HFS-MR Relay Module. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: Primary operating supply: HFS-MM 15-32 VDC, 600 uA HFS-MR 15-32 VDC, 6.5 mA INSTALLATION: In accordance with liste&s printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as monitor module and relay module accessories for use with listees separately listed compatible fire alarm control units. 01-28-2010fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2013 Listing Expires June 30, 2014 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division