Loading...
HomeMy WebLinkAbout1917 PALOMAR OAKS WAY; ; FA160047; Permit12/16/21, 4:07 PM FA160047 Permit Data City of Carlsbad Fire Alarm Permit Permit No: FA160047 1917 PALOMAR Job Address: OAKS WY Permit Type: FALARM Parcel No: 2120911900 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 8/29/2016 Approved: 9/6/2016 Issued: 9/6/2016 Inspector: Project Title: ARBOR SCENTIA T.I.: NEW STROE AND HORN STROBE DEVICES ON 2ND FLOOR Applicant: RED HAWK FIRE & SECURITY 920 SOUTH ANDREASEN DR SUITE 102 ESCONDIDO, CA 760-233-9787 Owner: WASATCH CORNERSTONE HOLDINGS L LC 595 S RIVERW000S PKWY #400 LOGAN UT Fees ($) Add'I Fees ($) Total ($)!Balance($) 314 0 314 j 0 1/1 FIRE ALARM SYSTEM SUBMITTAL For ARBOR SCENTIA CORNERSTONE CORPORATE CENTER 1917 PALOMAR OAKS WAY, SECOND FLOOR, CARLSBAD, CA 92008 Submitted By: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 P FA1 60047 1917 PALOMAR OAKS WY 20 PROJECT INFORMATION SHEET PERMIT NUMBER: INSTALLING CONTRACTOR: Red Hawk Fire & Security 920 South Andreasen Drive, Suite 102, Escondido, California 92029 Phone: (760) 233-9787 CONTRACTORS LICENSE: C-10/C-16 #713099,11/30/16 PROJECT MANAGER: John Stasukevich PROJECT NAME: ARBOR SCENTIA PROJECT ADDRESS: CORNERSTONE CORPORATE CENTER 1917 PALOMAR OAKS WAY, SUITE 200, CARLSBAD, CA 92008 SCOPE OF WORK: TENANT IMPROVEMENT S August 25, 2016 Re: Arbor Scentia Cornerstone Corporate Center 1917 Palomar Oaks Way, Suite 200, Carlsbad, CA 92008 Tenant Improvement Red Hawk Fire & Security is pleased to submit the following equipment for your approval. All equipment is U.L. approved and California State Fire Marshall listed. The building is 100% sprinklered. QTY. MODEL NO. DESCRIPTION C.S.F.M. 2 ZR-MC-CW Multi Candela Strobe, Ceiling Mount 7125-0067:0252 3 ZH-MC-CW Multi Candela Horn Strobe, Ceiling Mount 7125-0067:0248 Respectfully Submitted, RED HAWK FIRE & SECURITY 0 SIEMENS Data Sheet Fire Safety Products Notification Appliances ZH & ZR - Strobes, Horns, & Horn I Strobes I Application: Indoor L '1 • Fl$E ______ RTLI ZR&Z%t. 1iiëJ 1(Ies1 (for mounting) Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, the Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACP5), as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD-4TM NAC Extenders with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (Series 'ZH') - Ceiling-mount models feature field-selectable Candela settings of 1 5/30175195cd and 115/177cd - Wall-mount models feature field-selectable Candela settings of 15130/75/11 Ocd and 1 35/1 85cd - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce one (1) flash per second - "Special Applications" listed with Siemens panels - EZ Mount Universal Mounting Plate (Model ZB Series) —uses single plate for ceiling and wall mount installations - EZ Mount design—with separate base plate _provides ability to pre-wire the base and test the circuit wiring before the walls are covered - ®UL Listed & @ULC Listed, FM (#3028994) Approved; CSFM Approved (Series 'ZH': #71250067:0248 —> Fire Alarm Devices For The Hearing Impaired) CSFM Approved (Series 'ZR': #71250067:0252 —> Fire Alarm Devices For The Hearing Impaired) - ADA! NFPA compliant Specifications General - Audible/Visual notification appliances are listed for indoor use only - Appliances are listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) - Appliances use a universal back plate, which allows mounting to a single-gang, double-gang, 4-inch-square (10.2 cm.), 4"-octal (10.2 cm.), or a 3-1/2" (8.9 cm.) octal backbox - Two-wire configurations allows capability for directly connecting appliances to the mounting back plate - Continuity check will occur for entire NAC circuit prior to attaching any audible I visual-notification appliances - A cover fits over the mounting plate for protection to dust and other outside elements S . Cover is easily removed when the appliance is installed over the back plate - Removal of an appliance will result in a Trouble condition by the Siemens Fire Alarm Control Panel (FACP) 'Z' Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) . Strobes and Audible Strobe Combinations - Strobe appliances produce a minimum flash rate of 60 flashes per minute (one [1] flash per second) over the Regulated Input Voltage Range, and incorporate a Xenon flashtube enclosed in a rugged Lexan® lens - Strobes are available with two (2) or four (4) field-selectable settings in one (1) unit, and are rated - per ®UL 1971 - for up to: 15/30175/110cd for wall mounted 1 351185c for wall mounted 1 5130175195cd for ceiling mounted 11 5/1 77cd for ceiling mounted - Strobes operate over an extended temperature range of 32°F to 120°F (0°C to 490C), and be listed for maximum humidity of 95% RH - Strobe inputs are polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Siemens FACP Audible and Audible I Strobe Combinations - Horns and horn I strobes are listed for Indoor use under ®UL Standard 464 - Horns are able to produce continuous synchronized output or a Temporal Code-3 synchronized output - Horns have at least two (2) sound-level settings of 90 and 95 dBA Synchronization Modules - The strobe portion, when synchronization is required, is compatible with the Siemens DSC sync modules; the Siemens 50-point, 252-point and 504-point S addressable FACPs, as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD-4 TM NAC Extenders with built-in sync protocol - The strobes will not drift out of synchronization at any time during operation - Audibles and strobes are able to synchronize on a two-wire circuit with the capability to silence the audible, if required - Strobes revert to a non-synchronized flash-rate, if the sync module or power supply should fail to operate (i.e. - contacts remain closed) - All notification appliances are listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their "Regulated Input Voltage Range" > Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on ®UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93°h (1 2%) Series ZH horns are listed under ®UL Standard 464 for audible signal appliances (Indoor use only) Mounting Diagram 4.85 - i.- I. S6 -! - - H - SIEMENS Industry, Inc. (Shown In Inches) Building Technologies Division Mounting Diagram -OPTIONAL SECURING SCREWS slut SCREWDrM2-..-J Installation With the provided pan head screws, install mounting plate to a: - single-gang; - double-gang; -4" (10.2 cm.) square; -4" (10.2 c., octagon backbox Connect the field wiring. 3.) Address wires back into bachbox. Place dust cover over mounting plate to protect the terminals while performing the wiring-continuity check. Remove dust cover before snapping or installing the appliance onto the mounting plate Technical Data Removal -r- )gpodant: Device only has one (1)mounting orientation. Match the top of the base to the top of the device. 1.) if it is desired to further secure the device to the base, then use the two (2) optional screws which are provided in the shipment. To install, punch out the screw holes located at the top and bottom of the device. 8.) To remove the appliance, push a small, flat-bladed screwdriver into the side opening. The screwdriver must clear the snap release opening by 1/4 '(0.64cm.), in order for the appliance's snap to disengage. Iiupori.ani: Do not pry off the housing with a screw driver. ZH Horn: Wall and Ceiling Mount Operating Voltage (Special Application) Per ®UL 464 Input Voltage Low* High* 7DC 16.0-33.OVDC 0.018 0.044 FWR 16.0-33.OVRMS 0.045 0.075 * Current draw is the tame for the Continuous Horn, Code 3 . Horn, and March Time settings ZH Horn I Strobe Series: Wall Mount S Current Ratings (AMPS) MAXIMUM RMS Current- with jgh dBA Setting Input Voltage 15cd 30cd I 75cd ll0cd 135cdf 185cd DC 116.0-33.OVDC 0.078 0.113 10.19510.25910.3711 0.506 FWR 16.0-33.0VRMS0.141 0.200 10.30210.40610.52110.722 Current Ratings (AMPs) MAXIMUM RMS Current- with Low dBA Setting Input Voltage j 15cd 30cd I 75cd 95cd 11 35c I 185cd DC 1 16.0- 33.OVDC 0.070 10.107 10.188 0246 10.29010.39110.497 324 10.455 FWR 116.0-33.OVRMSI 0.123 10.179 10.699 ZR Strobe Series: Wall Mount Current Ratings (AMPs) Strobe Setting - (Cd) Input Voltage 15cd I 30cd I 75cd llOcd 135cd 185cd DC 16.0-33.OVDC 10.06410.09810.17510.2331-o-.-318][0-445 FWR 16.0-33.0VRMS0.108 0.164 0.268 0.368 0.482 0.684 Current Ratings (AMPs) Strobe Setting - (Cd) Input Voltage 1 001 30cd I 75cd I 95cd 111 5c I 177cd DC 116.0-33.0VDC 11M70601 0.111 0.200 0.264 0.318 10.445 FWR 16.0-33.OVRMS 0.117 0.180 0.297 0.398 0.482 0.684 tfiIULC Directional Characteristics -3 dBA 35 degrees left; 40 degrees right .6 dBA 55 degrees left; 65 degrees right SIEMENS Industry, Inc. Building Technologies Division Current Ratings (AMPs) MAXIMUM RMS Current- with High dBA Setting Input Voltage t5td 30cd (Z5tt}95cd 115cd 177cd DC 16.0-33.OVDC 0.131 22-10.29210.37110.506 FWR 16.0 - 33.OVRMS 0.14910.21610.33110.4361 0.5211 0722 Current Ratings (AMPS) MAXIMUM RMS Current- with Low dBA Setting Input Voltage 15cd 30cd 75cd 95cd ll5cd 177cd DC 16.0-33.OVDC 0.075 10.12110.213 0.277 0.324 10.455 FWR 116.0-33.OVRMS 0.131 0.195 10.319 0.421 0.497 10.699 ZH and ZH-MC Series: Wall and Ceilinq Mount dBA Sound Output Description Volume Reverberant Per IJL 464 16.0 VDC 24.0 VDC 33.0 VDC Continuous Horn Low 77 81 83 High 83 87 90 Code 3 Horn 11 (or March Time)* Low 72 76 79 I High 79 82 86 dBA Sound Output Description Volume Reverberant Per fiWLC-5525-99 20.0 VDC 24.0 VDC 31.0 VDC Continuous Horn Low 88 90 91 High 93 95 96 Code 3 Horn (or March Time) Low 88 90 91 High 93 1 95 96 ** Available only in sync mode. Technical Data - (continued) Notes: 1. Strobes will produce 1 flash per second over the Input Voltage range. These horn/strobe models are ®UL Listed to operate over a Voltage Range Limit from 1 6.OVDC to 33.OVDC for 24VDC applications using filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage. All models are ®UL Listed for indoor ceiling use with a temperature range of +0°C to +49°C (+32°F to +120°F) and maximum humidity of 93% +1- 2% RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance when stored in original cartons, and is not subjected to either misuse or improper handling of shipment. Details for Ordering - (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Number Description Mounting UL Options* ULC FM CSFM ZH-R 500-636159 Z Horn: Red B,D,E,F,X V V V V ZH-W 500-636160 Z Horn: White B,D,E,F,X V V V V ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F,X V V V V ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F,X V V V V ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F,X V V V V ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela (Wall), White B,D,E,F,X V V V V ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F,X V V V V 500-636166 Z Horn: Multi Candela (Ceiling), White B,D,E,F,X V V V V ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F,X V V V V ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F,X V V V V ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F,X V V V V ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall), White B,D,E,F,X V V V V ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red V V V V ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White V V V V ZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red I V V V V 500-636174 Z Strobe: Multi Candela (Ceiling), White V V V V ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red V V V V ZR-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White I B,D,E,F,X I V V V V ZB-R 500-636193 Accessory - (Includes base, dust cover, mounting _screws _and _installation _sheet) V V V V Z8-W 500-636194 Accessory - (Includes base, dust cover, mounting screws and installation sheet) V V V V V = Listed /Approved * = Refer to data sheet #: 2585 for detailed mounting options Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road SIEMENS Industry, Inc. Florham Park, NJ 07932 East Oakville, Ontario August 2016 Building Technologies Division Tel: (973) 593-2600 (511) L6H 0H6 / Canada Supersedes sheet dated 6/2015 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 (Rev. 5) URL: www.usa.Siemens.com)Fire URL: www.Siemens.CA S STATE FIRE MARSHAL LISTING S SHEETS CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 57'0252 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.esteban@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. Models ST-MC-CW, ST-HMC-CW, ZR-MC-CR, ZR1tCC ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, llOcd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd S ZR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -w are wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: 9-1 O-2007mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct I?V, operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7d250.0:62:Q248 Page 1 of I CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: Evelyn Esteban (973) 593-6582 Fax (973) 593-6652 Email: evelyn.estebansiemens.com DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns / Strobes. Models NS-MC-CR, NS-MC-CW, NS-HMC-CR, NS-HMC-CW, ZH-MC-CR, C=OW ZH-HMC-CR, ZH-HMC-CW are horn / strobes for ceiling mount only. Suffix CR or CW are for ceiling and color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115 / 177 cd NS-MC, ZH-MC = 15/30/75/110 cd ZH-HMC, = 135/185 cd Flash Rate: 60 flashes / minute • INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as audible and audible /1 visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details Note: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation ) in accordance with NFPA 72, 2002 Edition. NOTE: 09-07-2007 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division