Loading...
HomeMy WebLinkAbout1959 PALOMAR OAKS WAY; 300; FPC2018-0363; PermitPERMIT REPORT tr3ity of Carlsbad Print Date: 12/16/2021 Job Address: 1959 PALOMAR OAKS WAY, # 300, Permit Type: FIRE-Construction Commercial Parcel #: 2130922600 Valuation: $727,834.99 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: LABYRINTH -SPRINKLER TI (134 HEADS) CARLSBAD, CA 92011-1310 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0363 Status: Closed - Finaled Applied: 11/05/2018 Issued: 11/27/2018 Finaled Close Out: 02/04/2021 Inspector: Final Inspection: Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, #244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $654.00 Total Fees: $654.00 Total Payments To Date: $0.00 Balance Due: $654.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 0 C 0 T-(DQ N N LO 's)-- 0 CO C C TrFeP >.- C,,' CO035 0<' MATERIAL DATA SUBMITTAL CNI )a) U. Labyrinth 1959 Palomar Oaks Way *300 Carlsbad, CA 92009 Page * Description Manufacturer 1-2 Pipe Allied Dyna-Thread Pipe - 3-10 Fittings Tyco Ductile Iron Fittings 11-12 Mechanical Tee Tyco Fig 40-5 Strap Tee 13-19 Sprinkler Reliable F1FR56 Sprinkler 20-23 Sprinkler Reliable G5-56 Sprinkler 24 Hanger Afcon Fig. 300 Ring Hanger 25 Hanger Afcon Fig 655 All Thread Rod 26-27 Attachment Sammy Wood Vertical Mount Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 DynamThread 0 S Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Comparison to L.W.T. Pipes S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (9 <~> @ Listed Approved Listed With its increased strength and lighter weight, Dyria-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyria-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40fDyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. Wt. Wt, (H20 Filled) Pcs/ Wtil.itt (21') Wtjtltt (24') WI/lilt (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1051 11/4, 1.408 1.870 2,54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114. 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 dhed 16100 S. Lathrop• Harvey, IL 60426 tqco/FlowControl ') 11350 Norcom Rd. • Philadelphia, PA 19154 TUBE& CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna Threadn S Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=l .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch40 is specified. Stamp Here S Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTMA 135, Grade and is in compliance with NFPA-13. All sizes of Super 40fDyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal I.D. WI. WI. (H20 Riled) Pcsl Wt/Lift (21') Wtil.lft (24*) WIll-lU (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 105 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 1h/2 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 1034 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured Us L with Exterior galvanized coating. BLT is (@ 9 manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: 5 Engineer: Specification Reference: System Type: Locations: Comments: S3-4 S tqC0 Fire & Building IProducts Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 S Pipe Fittings NPT Threaded, Ductile Iron General Description The TycoO Series 800 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there Is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties, ax- cress or implied, including warranties of merchantability and fitness for a particular curcose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. tregistered trademark of E. I. du Pont de Nemours and Company or Its affiliates. TFPI7IO Page 2of 10 TFPI7I0 Nominal Pipe Figure 813 Size ANSI A Approx. Inches Inches Weight Part DN (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 0N15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 0N25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 0N50 (57,1) (0,70) 2-1/2 2.69 2.70 86782 0N65 (68,3) (1,22) 0 01 _ B" FIGURE 811 FIGURE 813 900 ELBOW 450 ELBOW TABLE I NOMINAL DIMENSIONS FIGURES 811 & 813 Figure 811 B Approx. A B Inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 86204 1.94 1.00 (39,6) (1,49) (49,3) (25,4) TFPI7IO Page 3 of 10 FIGURE 812 90° REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. Number DN (mm) (mm) (mm) (mm) (kg) 3/4x1/2 1.19 1.19 0.63 0.63 0.33 86342 DN20x15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 DN25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x314 1.38 1.44 0.69 0.88 0.53 86211 DN25 x 20 (35,1) (36,6) (17,5) (22,4) (0,24) 1-1/4x1/2 1.31 1.50 0.63 0.94 0.64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-1/4 x 3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-114x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2 x 3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40 x 20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 x 1 1.63 1.81 0.88 1.13 0.99 86215 DN40 x 25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-112x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40x32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x3/4 1.63 1.94 0.88 1.38 1.39 86217 DN50 x 20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65 x 50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 (D 0 TFPI7I0 Page 5of 10 'fl FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING Nominal Pipe TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 Size A B Approx. A B ANSI Inches Inches Inches Weight Part Inches Inches DN (mm) (mm) Lbs. Number (mm) (mm) (kg) 1/2 1.13 0.56 0.33 86340 1.38 0.31 DNI5 (28,7) (14,2) (0115) (35,1) (1,9) 3/4 1.31 0.75 0.50 86341 1.63 0.56 DN20 (33,3) (19,0) (0,23) (41,4) (14,0) 1 1.50 0.81 0.85 86230 1.75 0.38 0N25 (38,1) (20,6) (0,38) (44,4) (9,7) 1-1/4 1.75 1.06 1.30 86231 2.00 0.56 DN32 (44,4) (26,9) (0,59) (5018) (14,0) 1-1/2 1.94 1.19 1.63 86232 2.19 0.75 IDN40 (49,3) (30,2) (0,74) (55,6) (19,0) 2 2.25 1.50 2.63 86233 2.63 1.13 0N50 (57,1) (3811) (1,19) (66,8) (28,7) 2-1/2 2.69 1.56 4.55 86234 3.00 0.75 DN65 (68,3) (39,6) (2,06) (76,2) (19,0) Approx. Weight Part Lbs. Number (kg) 0.18 72779 (0,08) 0.26 72778 (0,11) 0.44 72755 (0120) 0.54 72754 (0,24) 0.71 72753 (0,32) 1.15 72752 (0,52) 2.29 12758 (1,04) 0 TFPI7I0 Page 6of1O U S Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 A B C D E F ANSI Inches Inches Inches Inches Inches Inches Inches Weight Part DN Lbs. (mm) (mm) (mm) (mm) (mm) (mm) Number (kg) 1-1/2x1-1/4x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 DN40x32x15 (36,6) (33,3) (42,9) (17,5) (16,0) (28,7) (0,47) 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (38,1) (36,6) (44.5) (19,0) (19,0) (30,1) (0,50) 1-1/2x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 0.6.259 DN40x32x25 (41,4) (39.7) (46,0) (22,4) (22,4) (28,7) (0,59) 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40x32x50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88) 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40x40x15 (36.6) (36,6) (42,9) (17,5) (17,5) (28.7) (0.52) 1-1/2x1-1/2x314 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (381) (44,4) (19,0) (19,0) (30,1) (0.56) 1-112x1-112x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 0N40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2x1-1/2x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 DN40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) (0,68) 1-1/2x1-1/2x2 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN40 x 40 x 50 (55,5) (50,8) (36,6) (36,6) (31,7) 2 xl x 2 t2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DNSO x 25 x 50 (50,8) (57,2) (38,1) (33,3) (38,1) (0.99) 2x1-114x2 2.13 2.25 1.50 1.44 1.50 2.3186267 DN50x32x50 (54,1) (57,2) (38,1) (36,6) (38.1) (1,05) 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN50 x 40 x 15 (47.8) (19,0) (17.5) (33,3) (0,68) 2x 1-112x314 1.63 1.94 0.88 0.75 1.38 1.61 86269 DN50 x 40 x 20 (41,4)1) (49,3) (22,4) (19.0) (35,0) (0,73) 2x1-112x1 1.75 2.00 1.00 0.88 1.31 1.65 86270 DN50 x 40 x 25 (44,5)) (50,8) (25.4) (22,4) (33,3) (0,75) 2x1-1/2x1-1/2 2.06 2.19 1.31 1.19 1.44 2.03 86272 DN50 x 40 x 40 (38,1)V366) (52.4)2) (55,5) (33,3) (30,2) (36,6) (0,92) 2x1-1/2x2 2.25 2.50 1.50 1.44 1.50 2.37 86273 DN50x40x50 (57,1)5) (63,5) (38,1) (36,6) (38,1) (1.07) 2x2x1/2 1.50 0 1.88 0.75 0.75 1.31 1.50 86222 DN50x50x15 (38,1)1)(47,8) (19,0) (19,0) (33,3) (0.68) 2x2x314 1.63 3 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) ) (49,3) (22,4) (22.4) (35,0) (0,76) 2x2x 1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 0N50 x 50 x 25 (44,5) (44.5) (50,8) (25,4) (25,4) (33,3) (0,86) 2x2x1-114 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28,7) (36.6) (0,93) 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55.6) (31,8) (31,8L (38,1) (0,96) 2 x 2 x 2-1/2 2.63 2.63 2.38 1.75 1.88 1.44 3,67 86227 0N50 x 50 x 65 (66.8) (66.8) (60,5) (44,5) (47.8) (36.6) (1,66) 2-1/2 x 2 x 3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65x50x20 (44,5) (41,4) (58,7) (15,9) (22,4) 1 (44,5) 1 (1,01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 S Page 8 of 10 TFPI7IO 11TT'!, j flhlll FIGURE 820 CAP FIGURE 830 BRASS SEAT UNION FIGURE 719 PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Part Inches Inches Weight Part Inches Weight Part DN (mm) Lbs. Number (mm) (mm) Lbs. Number (mm) Lbs. Number (kg) (kg) (kg) 1/2 0.88 0.15 72776 1.88 0.81 0.47 86207 0.94 0.10 86292 DN15 (22,4) (0,06) (47,8) (20,6) (0,21) (23,9) (0,04) 3/4 1.00 0.22 72777 2.00 0.94 0.66 86275 1.13 0.18 86293 DN20 (25,4) (0.10) (50,8) (23,9) (0,30) (28,7) (0.08) 1 1.18 0.33 72824 2.19 0.81 1.08 86276 1.25 0.28 86294 DN25 (30,0) (0,15) (55,6) (20.6) (0,49) (31,7) (0,13) 1-1/4 0N32 1.31 (33,3) 0.54 (0,24) 72756 2.50 (63,5) 1.06 (26,9) 1.54 (0,70) 86277 1.38 (35,1) 0.50 (0,23) 86295 1-1/2 DN40 1.38 (35,1) 0.68 (0,31) 72822 2.63 (66,8) 1.19 (30,2) 2.03 (0,92) 86278 1.44 (36,6) 0.70 (0,32) 86296 2 0N50 1.50 (38,1) 0.96 (0,43) 72823 3.13 (79,5) 1.63 (41,4) 3.15 (1,43) 86279 1.50 (381) 0.90 (0,41) 86297 2-1/2 1.75 1.80 72825 - - - - - - - DN65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 S TFPI7I0 Page 9of 10 S IAJ I _ FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx. ANSI Inches Inches Weight Part Inches Weight Part Inches Inches Weight Part DN (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 1/2x1/2 1.50 0.20 72751 - - - - - - - DN15 x 15 (36,1) (0,09) 112x1/2 2.00 0.27 72980 - - - - - - - DN15 x 15 (50,8) (0,12) 3/4x3/4 1.50 0.22 72981 - - - - - - - DN20x20 (38,1) (0,10) 3/4 x 3/4 2.00 0.31 73982 - - - - - - - DN20 x 20 (50,8) (0,14) 3/4 x 1/2 1.75 0.69 0.38 86772 DN20 x 15 - - - (43,2) (17,5) (0,17) 1 x 1/2 1.06 0.22 72726 1.69 0.50 0.38 86228 DN25x 15 - - - (26,9) (0,10) (42,9) (12,7) (0,17) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 DN25x20 - - (26,9) (0,08) (43,2) (12,7) (0,24) 1-1/4x1 - - 1.19 0.31 72763 - - - - DN32x25 (30,2) (0,14) 1-1/2x1 - - 1.25 0.53 72757 - - - - DN40 x 25 (31,7) (0,24) 1-1/2x1-1/4 - - 1.25 0.35 72764 - - - - DN40x32 (31,7) (0,10) 2x1 - - 1.38 0.75 72759 - - - - DNSO x 25 (35,1) (0,34) 2 x 1-1/4 - - - 1.38 0.69 72761 - - - - DN50x32 (35,1) (0,31) 2x1-1/2 - --j 1.38 0.62 72775 - - - - DN50 x 40 (35,1) (0,28) tqC0 Fire & Building IlProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap S General Description Usting/Approval InIormaton The Figure40-5 Strap isaneconomicalalternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las withtheapplica ble standards of the National Fire Protection Association, in addition to the standards of anyotherauthorities ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershou/dbe contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Page 1 of 2 Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet 1FP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "E" EPOM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutihe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be Immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. September 2004 Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated byownershipwfthlyco Fire Products orfor products and components which have been subject to misuse, improperinstallation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any otherAuthorkiesHaving Jurisdiction. Materials found by Tyco Are Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Are Products neither assumes, nor authorizes any person to assumefor, any other obligation inconnectionwifh the sale of products or parts of products. Tyco Fire Productsshallnotberesponsibleforsprinklersystem designerrorsorinaccurateorincompletelnfonnation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCOFIREPRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGO&V WARR4NT(ISM4OEWLIEUOt ANYANO ALL OTHER WARR4NI9S EXPRESS OR (B TFPI72O Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg. 11/4 X /2° 2.00 1.50 3.50 1.20 1/ie 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/4" X3/4" 2.00 1.50 3.50 1.20 1/I6 0.88 50.8 38.1 88.9 30.5 30.2 0.4 1/4°X i 2.31 1.68 3.50 1.20 1/i 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/20 X 1/2I 2.12 1.62 3.50 1.32 1/16 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2 3/40 2.12 1.62 3.50 1.32 1/16 0.88 53.8 41.1 88.9 1 33.5 30.2 0.4 11/20 X 14 2.43 1.80 3.50 1.32 1/i 1.13 61.7 45.7 88.9 33.5 30.2 0.5 20x'/2' 2.36 1.86 3.74 -_95.0 1.55 1/i 0.88 59.9 47.2 39.4 30.2 0.4 2"X3/40 2.36 1.86 3.74 1.55 1/i 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" P 2.67 2.04 3.74 1.55 1/t 6 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2" X 1/20 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2" X3/4° 2.61 2.11 4.25 1.80 1/I6 0.99 ________ 66.3 53.6 108.0 45,7 30.2 0.4 2'/2' x i' 2.92 2.29 4.25 1 1.80 1/16 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 11/40 X V. 8 1V20 X 1" 6 20 x 1' 6 21/20 x 1 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2012 TFP1 720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. 12 ,e General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions ((H-i 000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Concealed Horizontal Sidewall Pendent Bulletin 014 Rev. L liable Model Fl FR Series Quick Response Standard Spray C C Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall El Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types . Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schadenverhutung GmbH *NSF Certified to NSF/ANSi Standard 61 Annex G EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1 FR56, F1FR56LL, F1 FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models Fl FR56, Fl FR56LL, Fl FR42, Fl FR42LL, XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Conventional Recessed Pendent/Fl/F2 * Recessed PendentjFP XLH Recessed Pendent F1/F2 4) XLH Recessed Pendent FP S F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *p/n tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup 0 14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL0 K 5.6 Quick 1/2" NPT See See F1FR42 **F1FR42LL0) K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" Fl FRXLH Ratings" Table. F1FR28 K2.8 Low Lead Sprinklers available only with Temperature Rating 200°F/930C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDAAlloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape S 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor _______________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (131/2) 5.6 I 80 2.25' (57mm) 1.2,3,4,6 I 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 I RA14134 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA1421'14 RA141 1 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor ________________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Size US Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1,5 RA1415 7/16(11mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1,5 RA1410 (1) cULus listed corrosion resistant (Polyester coated) sprinkler. "DuPont Registered Trademark 91 4. Vertical Sidewall "DuPont Registered Trademark Sprinkler Type Deflector to Ceiling Distance (M n. - Max.) Upright 4" (102mm) - 12" (305mm) Pendent 4(102mm) - 12" (305mm) Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) I 1/2" NFl (R1/2) 2.8 40 2.25" (57mm) RA1411 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R1/2) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) 1 1/2" NPT (R1/2) 1 4.2 60 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions 70 (700705 0 /0 07077700 ,_-I IURN COLLAR 7010 PLOt FACE OF FIllING ID FACE OF CEILING 077007000 \\ I ' \ I flflCELtCW At77NE0LU7 RECESS ?T2704,,,ol AT WAIMUM RECESS JIBTIS~-] CE - AWOSIMOLT I II1EI IIWII L I III III till I I AT L700IMUM RECESS I f l'I flJ (Ar WNIMW RECESS - fl I At 70077GM RECESS - 1-118T2&6-1 - AT 0/7077GM RECESS - I-5/0T41.3m,n1 IF Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Fl or F2 X I/PRODUCER 2 5/O' GM. [6& 7--1 - HOLE IN COILING 2 5/I6 00.. [570 CUP / PA CE OF FIllING PACE OP COILING OLMELODON A MAXIMUM 7-I/2T38,mJ JAT r 00707077 I4I27oo, AOIJLEL7MOII AT MAXIMUM RECESS - 9/t6TI4JLOm] AT MINIMUM RECESS - IT25.lo,R,J (82.6,RR CA ,J 1 Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 RA1485 23 15mm ½" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel FIFE (TeflonXI)* Plated - cULus listed corrosion Resistant FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = ("[25.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4(19mm] AT MINIMUM RECESS = 3/879.5mm] 2 1/4" HOLE OIA. [5 7.2mm] I" X 1/2" REDUCER F? ESCUTCHEON r002AT MAXIMUM RECESS 7-3/8[34.9mm] H 7 AT MINIMUM RECESS = 2-1/76752.4mm] V F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'r41.3mm1 AT MINIMUM RECESS 2-1/76752.4mm] I [3.2mm] Model Fl FR56 Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall Nominal K Factor Sprinkler Approval Organizations Sprinkler _________________ Height and Type of Approval Nominal Orifice Thread Size Identification US Metric Light Hazard Ordinary Numbers (SIN)Hazard ½" (15mm) ½" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 cULus Listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Electroless Nickel PTFE (TeflonB)* Plated - cULus listed Corrosion Resistant Horizontal Sidewall 15/16" DIA.JjJ4 2 27/32" 0/A. [72.2mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER I WRENCH BOSS. Fl ESCUTCHEON 3/4(19mm] ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT I (1) 4-12" [101.6mm-304.8mm] CEILING TO DEFLECTOR RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [ID 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Note: For Recessed HSW Sprinklers use installation wrench GFR2. cULus permits use with Fl, F2 or FP escutcheons for "Light Hazard" only. While FM limits use for the same hazard with the F2 escutcheon only. Model Fl FR56 Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor Thread Size Model Temp. Rating Max. Ambient Temp Bulb Color Approvals Sprinkler Identification Number(SIN) US Metric Sprinkler Cover ½" (15mm) 5.6 80 ½" NPT F1 FR 135°F/570C 135°F/57°C 100°F/380C Orange 1 RA1414 ½" (15mm) 5.6 80 1 ½" NPT I F1 FR 155°F/680C 1350F/570C 100°F/380C Red 1, 4(1), 6 RA1414 ½" (15mm) 5.6 80 ½" NPT F1 FR 175°F/790C 165°F/740C 100°F/380C Yellow 1 RA1414 ½" (15mm) 5.6 80 ½" NPT F1 FR 200°F/930C 165°F/740C 150°F/65°C Green 1 RA1414 (1) For VdS only = 1550F/680C Norbulb and 1/2" [12,7mm] adjustment. Model Fl FR56LL Quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: Nominal Orifice "K" Factor I I Thread Size I Model I Temp. Rating Max. Ambient Bulb Color Approvals Sprinkler Identification us I I Metric Sprinkler I Cover Temp Number(SIN) ½" (15mm) 5.6 80 ½" NPT F1FR56LL 200°F/93°C 1650F/740C 150°F/650C Green 1,5 RA1414 "DuPont Registered Trademark 5. I" x 1/2" REDUCING TEE OR ELBOW S ET1 E 2 5/16" 0/A CUP I CEILING VER USTM COit3 5/I6" OJ SPRINKLER I" x 1/2" REDUCING TEE OR ELBOW —2 5/8' DIA. HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING _.._.._....TO FACE OF CEILING DIMENSION 15/16" 2 5/16" 0/A - CUP -_.. CEILING—A 5/16" MAX. COVER ADJUSTMENT COVER PLATE— ASSEMBLY 5/16" 0/A. SPRINKLER - 2 5/8" DIA. I-IDLE IN CEILING I 1/2 MAX. FACE OF FITTING ., TO FACE OF CEILING DIMENSION 3/4" CONCEALED, 1/2" ADJUSTMENT 07FGO CONCEALED, 5/16" ADJUSTMENT o,ni S S Figure 1 Installation Aid A protective cap is included for use during installation, Important: The F1FR56 Sprinkler with Model OCR cover plate is not an FM Approved combination, Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed, The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Quick Response Sprin- klers are to be installed as shown. The Model Fl or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Sprinklers. The use of any other recessed escutcheon will void all approvals and ne- gate all warranties. When installing Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Sprinklers, use the Model D Sprinkler Wrench, Use the Model GFR2 Wrench for install- ing F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent Sprinklers, Any other type of wrench may damage these sprinklers. NOTE: A leak tight ½" NPT (R112) sprinkler joint can be obtained with a torque of 8-18 ft-lbs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprinklers. The Models F1FR56/CCP & F1FR56LL/CCP Concealed Sprinkler use the 1/2" orifice, 1/2 NPT (R112), Model F1FR56 & F1FR56LL Pendent Sprinkler with a threaded Model CCP cup which is factory attached to the sprinklers. The Model F1FR56 Pndent is available in temperature rating of 135°F (57°C), 155°F (680C), 175°F (79°C) or 200°F (930C). The Model F1FR56LL Pendent is available only in a rating of 200°F (930C). The concealed sprinkler assemblies are com- pleted by the installation of the attractive low profile Model CCP push on cover plate assembly, rated 135°F (57°C) or 165°F (74°C) for the Fl FR56 and 165°F (74°C) for the FIFR56 LL. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded en- *DuPont Registered Trade Mark Figure 2 gagernent. A choice of two cover plate assemblies provide either 1/2" (13mm) or 5/8" (8mm) of cover adjustment, Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2/8" (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon* based thread sealant should be applied to the sprin- kler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be tak- en to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impedi- ment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other concealed cover plate/cup assembly with the Model F1FR56 Pendent Sprinkler or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifi- cally listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and in- stallation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrench- es are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PRO- TECTORS. C Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0c Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High " 141 286 225°F (107°C) Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus perms use with Fl F2 or F escutcheons for light hazard" only, while FM limits use for same hazard with F2 escutcheon only Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate' Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) 1 White Painted Special Application Finishes Sprinkler Escutcheon Cover plate 1) Electroless Nickel PTFE(TefIon )*(7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass (3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint26 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish appliesonlyto RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. *DuPont Registered Trademark 7. Model G5-80, Model G5-56, 0 Model G5-42, Model G5-28 C Quick Response Concealed Automatic Sprinkler LU Plain Cover Plate Bulletin 034 Rev. D ReI m ®R iabui UL Quick Response FM Standard Response Concealed Sprinkler With a 3/4 (19mm) Adjustment Features Cover plate attachment (Plain or Perforated) with 3/4" (19mm) assembly adjustment. Smooth aesthetic ceiling profile. Factory installed protective cap. Available in Chrome and White as Standard Finish- S S es. Special Application Finishes are also available. 5. Ordinary and Intermediate temperature rating. For additional Sprinklers refer to Bulletin 154 for Technical Specification and Approvals Approvals & Listings 1. Underwriters Laboratories Inc. and cULus - Quick Response G5-80, G5-56 - Light Hazard and Ordinary Hazard Occupancies G5-42 - Light Hazard Occupancies G5-28 - Light Hazard Occupancies 2, Factory Mutual Research Corp. (FM) - Standard Response (See Page 3) G5-56 & G5-28 only. See the most recent FM Global Property Loss Prevention Data Sheets for installation and use guidelines. Loss Prevention Council (LPCB, UK) - Standard Response G5-56 - Light Hazard and Ordinary Hazard Occupancies VdS Schadenverhutung GmbH - Standard Response EC-Certificate of Conformity 0832-CPD-2062 U.S. Patent number 6,554,077. Application The Reliable Model G5-80, G5-56, G5-42 and G5-28 are the most versatile quick response concealed sprinklers avail- able. It provides the best form of fire protection while offering an attractive appearance and 3/4" (19mm) of cover adjust- ment for ease of installation. The small diameter cover plate assembly is easily attached and blends into the ceiling, con- cealing the most dependable fire protection available, an au- tomatic sprinkler system. , ------------- ------------------ /1 Perforated Cover Plate The Model G5-80, G5-56, G5-42 and G5-28 are designed for use where aesthetic appearance is important. Offices, hos- pitals, motels and restaurants are but a few of the applications where it can be used. The Model G5-80, G5-56, G5-42 and G5-28 are UL Listed Quick Response Concealed sprinklers intended for use in accordance with NFPA 13, FM Approves the G5-56 and the G5-28 sprinkler as a standard response concealed sprinkler intended for use in accordance with FM Loss Prevention Data Sheet 2.0. Product Description The Reliable Model G5-80, G5-56, G5-42 and G5-28 uses a proven quick response fusible element in a standard style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate assembly. The threaded engagement provides 3/4" (19mm) of cover adjustment. The flat cover plate is attached to the skirt using either 135°F (57°C) or 165°F (74°C) ordinary tempera- ture classification solder. When the ceiling temperature rises, the solder holding the flat cover plate melts, the flat cover plate released thus expos- ing the sprinkler inside to the rising ambient temperature. The subsequent fusing of the element opens the waterway and causes the deflector to distribute the water. Any secure engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model FC Sprinkler Wrench UL Listing Category Sprinklers, Automatic and Open Quick Response Sprinkler UL Guide Number VN IV Installation Do not install the G5-80, G5-56, G5-42 and G5-28 in ceilings • which have positive pressure in the space above. Cut a 2 /8" inch (67mm) diameter hole is cut in the ceiling, the sprinkler is easily installed with the Model FC Wrench. The wrench has a socket drive which is inserted into the body of the sprinkler. When installing a sprinkler the wrench is first positioned into the sprinkler/cup assembly until the wrench socket engages the body of the sprinkler. The sprinkler is then tightened into the pipe fitting. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER! CUP ASSEMBLY. Install the cover plate by hand turning the cover in the clockwise direction until it is tight against the ceil- ing. A protective cap is provided to protect the drop-down sprinkler deflector from damage which could occur during construction before the cover plate is installed. The cap is factory installed inside the sprinkler cup. Remove cap to install sprinkler, then re- install cap until the cover plate is installed. Maintenance The Model G5-80, G5-56, G5-42 and G5-28 should be in- spected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, am- monia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in • any way. Concealed sprinklers cover plates can not be painted in the field, after installation or have any other coating applied other than the factory finish. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be main- tained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Sprinkler Model Nominal Orifice Flat Cover Plate Plain or Perforated Flat Cover Plate Assembly Finish Inlet Type Cover Plate Finishes(') Standard Finishes Chrome White Paint Special Application Finishest2 Bright Brass Finished Bronze Black Plating Black Paint Off White Satin Chrome Other finishes and colors are available on special order. Consult factory for details. Coverplate custom paint is semi-gloss, unless specified otherwise. For the perforated style cover- plate, consult factory for avail- ability on these and other cus- tom finishes. Maximum Working Pressure 175 psi (12 bar) 100% Factory tested Hydrostatically to 500 psi (34.5 bar) Temperature Rating I I Cover I I Max. Ambient Classification Sprinkler I Temp. Ordinary 1651F/741C 1351F/57°C i 100°F/380C Intermediate I 212°F/100°C I 165°F/74°C 150°F/66°C 2. C Technical Data Sprinkler Model Sprinkler Inlet Total Adjustment Nominal Orifice Nominal K Factor ______ Thread Approvals Sprinkler Identification (SIN) US Metric G5-80 Non Adjustable 3%"(19mm) 17/32"(l5mm) 8,0 115 3%" NPT(R3,4) 1 RA3412 G5-56 Non Adjustable 1 34"(19mm) 1 1/2"(l5mm) 1 5.6 80 ½" NPT(R½) 1,2,3,4,5 1 RA3415 G5-42 Non Adjustable 3,4"(l9mm) 7/16"(lOmm) 4,2 60 1/2" NPT(R½) 1 RA3413 G5-28 Non Adjustable 34" (19mm) /" (10mm) 2,8 40 1/2 NFl (R½) 1,2 RA341 1 For VdS Approval, temperature rating sprinkler 1650F174°c and cover plate 1350F/570C only! x 7/2" REDUCING TEE OR ELBOW I 1" 3/4" REDUCING TEE OR ELBOW G58O ONLY 2k" [58.42mm] 0/A CUP " [19.05mm] MAX. COVER ADJUSTMENT 1/4 [6.35 MIN TO CEILING J 1" [25.4mm] MAX. if DROPPED DEFLECTOR TO CEILING 8 L""J HOLE IN CEILING 7 2-1/4" [57. 15mm] MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION " [4.96mm] FLAT COVER PLATE ASSEMBLY " [84.21mm] D/A. LI C SPRINKLER COVER PLA TE: 3/4" [19. 05mm] ADJUSTMENT Notice FOR USE AS A REPLACEMENT OF MODEL G4A SPRINKLERS x 7/2W REDUCING TEE OR ELBOW -Iii--- - I RELIABLE P/N 6999997900 71 I xj BRASS NIPPLE EX7-. 2e [58.42mm] 0L4 CUP J. (79.05mm) M4X COVER ADJUS7MENT I 1/4 (6.JSm MIN. CEILING J 1 [25.4mm) MAX. DROPPED DEFLECTOR To CEILING 2k" (66.55mm) I HOLE IN CEILING 3-1/76 [77.72mm) MAX, FACE OF FiniNG IV FACE OF CEILING DIMENSION 2-1/4[57.15mm] MAX. FACE OF NIPPLE EXT. 70 FACE OF CEILING DIMENSION /" (4.96mm) (84.2 1mm) DL4. FLAT COVER PLATE -1 ASSEMBLY SPRINKLER aRFMM COVER PLATE: 3/4" [19.05mm] ADJUSTMENT Testing has shown that use of a "nipple extension" will not affect the listing of the sprinkler. For RETROFIT installations, per NFPA 13 (2010) section 8.15.19.4, "which allows the use of nipples as the same pipe thread size as the existing outlet when revamping existing systems". Do not exceed 8-18 ft-lbs of torque during installation. 3. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly S qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. 9 Recycled ® (800) 431-1588 Sales Offices Paper Reliabi (914) 829-2042 Corporate Offices C (800) 848-6051 Sales Fax Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 11/14 P/N 9999970421 RING HANGER I thru 4 inch pipe 112 and 3/4 inch pipe 5 thru 8 inch pipe SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 specification. FINISH - Mu. Galvanized and Stainless Steel. LISTING - UL in US and CANADA. APPROVAL - Factory Mutual Research. CONFORMS WITH: Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society ANSIfMSS-SP-58 (Type 10); install in accordance with ANSI/MSS- SP-69. MAXIMUM TEMPERATURE - 6500F. FUNCTION - For fire sprinkler and general piping purposes. Swivel nut permits hanger adjustment after installation. FEATURES - lthru4 inch: * Offset edge for EASY pipe insertion. 1 thru 8 inch: * Full length knurl on swivel nut for better grip. UNIQUE FEATURES 1 thru3 inch: * UL listed to accept AFCON #310 Surge Restrainer. * Swivel nut Retained in ring to keep the assembly intact prior to installation. Removed easily if needed. * UL listed for use on CPVC pipe. ORDERING - Part # and pipe size. Index IMPERIAL MAX REC. LOAD LBS. METRIC* PIPE ROD PIPE ROD 1/2 3/8 400 10 400 20 10 1 318 400 25 10 1 114 3/8 400 32 10 3/8 400 0 10 2 3/8 400 50 10 21/2 3/8 600 65 10 3/8 600 80 10 3112 600 10 4 1000 100 __ S 1250 125 12 6 1250 12 8 2 1250 1501 200 * Order Part #300m Note: 1/2' Ring Hanger not <FM> approved F~ S 655 ALL THREADED ROD CUT TO LENGTH ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 NOTE; maximum Temperature: 750°F SIZE - 3/8 thru 7/8 inch rod in 1 inch increments. MATERIAL - Carbon Steel. FINISH - Plain, Electro-Galvanized and Stainless Steel. ORDERING - Part #, rod diameter, rod length and finish. 2/00 E5 Will] IIT (Veilical iTflTi Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Box Qty Weight Case (per 100) Qty 20 GST.750 3/4 1/4 100 4.75 1000 21 CST 100 1 1/4 100 5.00 1000 22 CST 200 2 1/4 100 6.50 1000 23 GST300 1 3 1/4 100 1 7.50 1000 24 IGST600 1 6 1 1/4 1 50 1 9.00 500 S WOOD - Sammys i #14 (Item #100-black) Sammys 1/4', 3/8" rod WOOD - 3/8" Rod &'7TI?1L.I lT1T1Th Use #14 Nut Driver (Item #100) Approvals Item # Model Shk Lgth Shk Dia FMTest Load, lb. ULlest Load lb. UL/FMActual Pipe Size Pullout Box Qty 10 GST.75 3/4 1/4 564#-6Ply 100 NFPA 11 GST10 1 1/4 210# - 7/16 OSB 100 6704 - 3/4" Ply IUL.FMNlPA 12 CST 20 2 1/4 9404 850# 3/4-2 1/2 17604-Fir 100 UL-NFPA * 27 CST 25-380 21/2 3/8 15004 4 21134-Fir 50 UL-FM-NFPA 13 CST30 3 1/4 14754 1500# 3/4-4 20604 -Fir 100 NFPA 403 GST40 4 1/4 2180# - Fir 50 NFPA 1 14 IGST60 1 6 1 1/4 1 1 2230# - Fir 50 #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod WlIl] riiRod(Veifical Use #14SW Nut Driver (Item #101) Item # Model Shk Lgth Shk Dia Actual Pullout Box Qty Weight (per 100) Case Qty 8 CST 2 2 1/4 1760# - Fir 50 7.00 500 * 06 CST 2.5-380 21/2 3/8 21134-Fir 50 10.00 500 15 IGST3 1 3 1 1/4 1 2275# - Fir 1 50 10.50 500 16 JGST4 1 4 1 1/4 1 2180#-Fir 1 50 1 10.60 1 500 17 ICST6 1 6 1 1/4 1 22304- Fir 1 50 1 10.95 1 500 Not less than 2" nominal width (11/2") TJI Joist/ Truss Consult truss manufacturer for recommended installation point. *pre_drilling may be required :3 for items #27 and #06. Tools available on page 9. 03 5- q Wood Joist S ( Double Sheetrock Ceiling Minimum 2" imbedment into base material for NFPA 13 compliance For vertical use. Install in center oflowerface. per NFPA1 L 26 Page 4 Note: Screws must be installed with appropriate nut driver to comply with warranty WOOD —Sidewinders IWlIS] VLIRodrum mIk11ITrrITh 'Use #I4SW Nut Driver (Item #101) Item# Model ShkLgth ShkDia I Actual I I Shear/Pullout I Box Qty Weight (per 100) ICase Qty 4016 SWG 100 1 1/4 I 100 7.50 I 1000 300 SWC 200 2 1/4 17254 - Fir 100 8.00 1000 IWlIS] IYItIITrI(11mizonta ll1 ITITITi Use #14SW Nut Driver (Item #101) Approvals Item# Model Shk Lgth Shk Dia IL Test Load lb. UIIFM Pipe Size ActualBox Shear/Pullout Qty Weight (per 100) 18 SWG 10 1 1/4 100 6.00 UL•NFPA 19 SWG2O 2 1/4 1250# 3 1725# -Fir 100 7.00 UL•NFPA * 26 SWG25-380 21/2 3/8 15004 4 2249# -Fir 50 10.25 - 25 ISWC,30 1 3 1 1/4 1 1 1 50 1 8.50 S #I4SW (Item #101-red) Sidewinders & Sammys 1/2" rod o. Prestressed Concrete C2 -j Page 5 Not less than 2" nominal width (11/2") up to 31/2" pipe; not less than 3" nominal width 4 & 5" pipe FloorJoist r ' TJI Joist! Truss Consult truss manufacturer for recommended installation point. *pre_drilling may be required for item #26. Tools available on page 9. II3 Minimum 2 112" from bottom for branch lines. Minimum 3" from bottom for main lines. Exception: I This requirement shall not apply to 2" or thicker nailing strips resting SHEETROCK -Toggle on top of steel beams. :1 i (II r(Verticalu miii Use #14 Nut Driver (Item #100) Item # Model Shk Lgth Shk Dia Actual Pullout Box Q, Weight Case Qty (per 100) 71 SST 300 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock #14 (Item #100-black) Sammys 1/4", 3/8" rod C I1fl D I tII r1k (VerticalMount) Use #14 Nut Driver (Item #100) Item# Model Shk Lgth1 Shk Dia Actual Pullout Pkg Qty Weight Case Qty (per 100) 70 ISST 30 3 1/4 450# Lath & Plaster 50 12.00 500 404# 2 Layers 5/8 Rock Note: Screws must be installed with appropriate nut driver to comply with warranty