HomeMy WebLinkAbout6250 EL CAMINO REAL; ; AS080067; PermitCity of Carlsbad Sprinkler Permit uI-1iI:I'I,I4 6250 EL CAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 2131100100 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 4/28/2008 Approved: 4/29/2008 Issued: 4/29/2008 Inspector: Project Title: TRI CITY WELLNESS BLDG. A THREE FIRE SPRINKLER INSPECTIONS @ $65/EA Applicant: MILLENNIUM FIRE PROTECTION SUITE F 101 COPPERWOODWY OCEANSIDE, CA 760-722-2722 Owner: ECR CORPORATE CENTER LP C/O MONICA R BROWNING 5600 AVENIDA ENCINAS #100 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 195 0 195 0 73flfbm-j-05 Oflflfl U Feb 12 2008 5:23PM MILLENNIUM FIRE PROTECTIO 7807222730 P.2 . . MILLENNIUM FIRE PROTECTION CORP. FLOW TEST DATA ADDRESS: 6250 El Camino Real, Carlsbad, CA DATE: February 2no 2008 TIME: 10:12 am STATIC: 92 psi RESIDUAL: 85 psi OUTLET SIZE: 2.5" PITO: 90 psi OBSERVED FLOW: 1450 gpm CALCULATED FLOW 00- 20 psi: 5112 gpm 101 Copperwood Way Suite F Oceanside, CA 92058 Phone (760) 722-2722 Fax (760) 722-2730 License# C16-869040 k,b 12 2008 5:23PM MILLENNIUM FIRE PROTECTIO 7607222730 Flow Test Record Test Hydrant Location In Ci h4 wvtcc (2 CoMo (( Hydrant ID No. Size Main (311 Static ............. 12. Residual........... Pressure Drop I (PDI 1).....K factor for POt 1 2-0-(o FlowHydrant(s) Hydrant 1 location St _V-EM_4_TM' &&,rAeri Hydrant 2 location'_l- rai Hydrant 3 location KI N Hydrant 1 Pitot 4 W1 PSI GPM: 4/ pp.. Size of Orifice__________ Hydrant 2 PitotØDPSI GPM: I50 Size of Orifice 2.6 Hydrant 3 Pitot _PSI GPM: v , Size ofOrifice.________ Total: 1I40 (Q) Calculated test' and flow data - Q _PD2k =Q2 PDPk Static: ..................... ci2 Desired Residual.......20 Pressure Drop (PD 2)1t1__________________________________K factor PD 2: 1 0.07 x 10,01 divided by '2-. Qa equals 5 )0r.) GPM at 20 psi residual Qi P02k POlk .Q2 Comments: Test conducted for: Conducted by:DOL 1*'- (Dvr Date: 2-(aOB Time: JO(ZaM P.1 ASoVDc+ M MILLENNIUM FIRE PROTECTION CRP 101 COPPERWOOD WAY SUITE F OCEANS IDE, CA 92058 760-722-2722 Job Name TRI-CITY WELLNESS CENTER Building : A Location 6250 EL CAMINO REAL, CARLSBAD, CA System : I Contract : 08-001 Data File BLDG A.wxl APPRovABnTP /X/ , --4 . CARLSBADIFERV DEPARTMIFEEN Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Page 1 TRI-CITY WELLNESS CENTER Date 021908 Hydraulic Design Information Sheet Name - TEl-CITY WELLNESS COMPLEX Date - 02-21-08 Location - 6250 EL CANINO REAL, CARLSBAD, CA Building - A System No. - 1 Contractor - MILLENNIUM FIRE PROTECTION Contract No. - 08-001 Calculated By - RDH Drawing No. - 1 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - VARIES Occupancy - FITNESS CENTER S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 C ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 C ) NFPA 231C C ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make TYCO D Area Per Sprinkler - 225.00 ( ) Dry Model TY3231 E Elevation at Highest Outlet - 32 C ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155° G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 332.32 Press Required - 76.41 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 02-02-08 Cap. - T Time of Test - 10:12AM Rated Cap.- Elev.- E Static Press - 92 0 Press - R Residual Press - 85 Elev. - Well Flow - 1450 Proof Flow S Elevation - 0 U P Location - TOWN GARDEN AND EL CAMINO REAL - P L Source of Information - MILLENNIUM FIRE PROTECTION AND CARLSBAD FIRE DEP. Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack N Single Row Conven. Pallet C C Auto. Storage Encap. SR Double Row Slave Pallet C ) Solid Shelf Non T A Mult. Row Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Page 2 TRI-CITY WELLNESS CENTER Date 021908 City Water Supply: Demand: Cl - Static Pressure : 92 Dl - Elevation : 10.827 C2 - Residual Pressure: 85 D2 - System Flow : 332.323 02 - Residual Flow : 1450 D2 - S~Adj stem Pressure : 76.408 Hose City) Hose Demand) D3 - System Demand : 432.323 Safety Margin : 14.846 150 140 130 p120 R110 E10° - Ci S 90 - C2 S80 ip-lbrcenll Under - U70 7in R6° E5° 40 30 20 10 - .. _____ .... .. 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N ' 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram MILLENNIUM FIRE PROTECTION CRP TRI-CITY WELLNESS CENTER 113,4 64.7 27.3 73.6 BI - B1.l- Bil -4 B12- 8134- B144- A114- Al 1' 113.4 18.5 73.6 1- I 113.4 1 73.6 I 82 33.1 63.4 10.2 B2 - B2.1-4 B22- B234- B244- A3 A2.14- 42 82 15.1 104.2 I 195.4 I 23.9 40.8 B3 - B3.14- --- -- --- - ------------ 44 4- 43 1 23.9 I 171.4 19.3 17 14,6 B44-B4.14-A5-A6 --- -- ----- -B5.1_B5 19.3 14.6 14.6 B5 9.4 7 B6 - B6.14- 47 -- B7.l4- B7 9.4 t 7 1 7 87 19.4 88---- ---- ----- -+A4--A5 36.2 22.7 89 -A9 1' I 1311.8 200.5 I 25%) BO - 40 t I 105.9 332.3 432.3 I A BO4 UGI4- HOSE TEST I 332.3 26.7 BA4-AA 79.2 26.4 26.4. BB - BB.IE- --- - -------------- ABlE- 48 1 26.4 I I 52.8 j 52.8 I 26 26.1. BC - BC.IE- --- - ------------ --- - AC.lE- AC 26 I I 26.8 1 26.8 I 26.8 26.4 BD - BD.IE- --- -- - --- - AD.IE- AD 26,8 Page 3 Date 021908 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 4 - TRICITY WELLNESS CENTER Date 021908 Fitting Legend Abbrev. Name % % 1 1% 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90StandardElbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T 90 Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD MILrLENNIJM FIRE PROTECTION CRP Page 5 TRI-CITY WELLNESS CENTER Date 021908 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. D001 31.67 5.6 16.14 na 22.5 0.1 225 7.0 D002 25.0 K = K @ EQ01 19.6 na 22.68 D003 25.0 K = K @ EQ01 19.29 na 22.5 D004 25.0 K = K @ EQ01 19.6 na 22.68 D005 25.0 K = K @ EQ01 21.77 na 23.9 D006 25.0 K = K @ EQ01 21.1 na 23.53 D007 25.0 K=K@EQ01 21.15 na 23.56 A6 32.0 35.53 na 822P 25.0 22.29 na B22U 32.0 5.6 19.96 na 25.02 0.1 225 7.0 B23P 25.0 21.61 na B23U 32.0 5.6 19.35 na 24.63 0.1 225 7.0 B24P 25.0 21.65 na B24U 32.0 5.6 19.5 na 24.73 0.1 225 7.0 A4 32.0 36.52 na A5 32.0 35.59 na B3.1 32.0 33.14 na B4 31.67 34.14 na B4.1 32.0 34.19 na B5.1 32.0 34.8 na B6 31.67 35.36 na B6.1 32.0 35.26 na A7 32.0 35.52 na B7.1 32.0 35.71 na BC 31.67 43.07 na BC.1 32.0 43.27 na AC.1 32.0 49.78 na BB 31.67 42.96 na 1313.1 32.0 43.17 na AB.1 32.0 49.87 na BA 31.66 42.73 na BliP 25.0 22.14 na B11U 32.0 5.6 19.68 na 24.84 0.1 225 7.0 B12P 25.0 20.07 na B12U 32.0 5.6 17.57 na 23.47 0.1 225 7.0 B13P 25.0 19.76 na B13U 32.0 5.6 17.36 na 23.33 0.1 225 7.0 B14P 25.0 20.07 na B14U 32.0 5.6 17.8 na 23.63 0.1 225 7.0 B2 31.67 32.17 na B2.1 32.0 29.14 na B22 32.0 23.66 na B23 32.0 22.95 na B24 32.0 23.11 na A3 32.0 37.25 na A2.1 32.0 40.92 na B8 31.66 40.85 na B9 31.66 41.69 na BO 31.66 42.31 na B 31.67 31.77 na B3 31.67 33.27 na B5 31.67 34.83 na B7 31.67 35.88 na BD 31.67 43.18 na BD.1 32.0 43.22 na AD.1 32.0 49.73 na AD 31.67 50.24 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard MILLENNIUM FIRE PROTECTION CRP Page 6 TRI-CITY WELLNESS CENTER Date 021908 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. AC 31.67 50.27 na AB 31.67 50.37 na AA 31.66 50.61 na B1.1 32.0 26.37 na Bil 32.0 23.35 na B12 32.0 20.89 na B13 32.0 20.64 na B14 32.0 21.14 na A1.1 32.0 42.87 na Al 31.66 45.38 na A2 31.67 45.56 na A8 31.66 46.85 na A9 31.66 47.93 na AO 31.66 49.28 na A 31.66 52.3 na BORA 0.0 71.67 na UG1 0.0 75.34 na HOSE 0.0 75.39 na 100.0 TEST 0.0 76.41 na The maximum velocity is 19.63 and it occurs in the pipe between nodes Bi and B1.1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 7 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 22.50 1.08 0.0 43.000 16.143 K Factor 5.60 to 120 0.0 0.0 -2.889 EQ01 22.5 0.1404 0.0 43.000 6.038 Vel = 7.88 0.0 22.50 19.292 K Factor= 5.12 D001 23.82 1.08 1E 2.305 1.000 16.143 K Factor@ node EQ01 to 120 0.0 2.305 0.0 BlIP 23.82 1.8145 0.0 3.305 5.997 Vel = 8.34 0.0 23.82 22.140 K Factor = 5.06 D002 22.68 1.08 1E 2.305 1.000 19.596 K Factor@ node EQ01 to 120 0.0 2.305 0.0 B12P 22.68 0.1422 0.0 3.305 0.470 Vel = 7.94 0.0 22.68 20.066 K Factor = 5.06 D003 22.50 1.08 1E 2.305 1.000 19.292 K Factor@ node EQ01 to 120 0.0 2.305 0.0 B13P 22.5 0.1404 0.0 3.305 0.464 Vel = 7.88 0.0 22.50 19.756 K Factor = 5.06 D004 22.68 1.08 1E 2.305 1.000 19.596 K Factor@ node EQ01 to 120 0.0 2.305 0.0 B14P 22.68 0.1425 0.0 3.305 0.471 Vel = 7.94 0.0 22.68 20.067 K Factor = 5.06 D005 23.90 1.08 1 E 2.305 1.000 21.770 K Factor @ node EQ01 to 120 0.0 2.305 0.0 B22P 23.9 0.1570 0.0 3.305 0.519 Vel = 8.37 0.0 23.90 22.289 K Factor = 5.06 D006 23.53 1.08 1E 2.305 1.000 21.104 K Factor @ node EQ01 to 120 0.0 2.305 0.0 B23P 23.53 0.1525 0.0 3.305 0.504 Vel = 8.24 0.0 23.53 21.608 K Factor = 5.06 D007 23.56 1.08 1E 2.305 1.000 21.146 K Factor @ node EQ01 to 120 0.0 2.305 0.0 B24P 23.56 0.1528 0.0 3.305 0.505 Vel = 8.25 0.0 23.56 21.651 K Factor = 5.06 *P6 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 8 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn A6 -2.41 2.203 3E 20.458 34.210 35.527 to 120 2T 27.277 47.735 0.0 A7 -2.41 -0.0001 0.0 81.945 -0.006 Vet = 0.20 0.0 -2.41 35.521 K Factor= -0.40 *P-9 B22P 23.90 1.08 1E 2.305 2.170 22.289 to 120 0.0 2.305 -3.032 B22U 23.9 0.1571 0.0 4.475 0.703 Vel = 8.37 B22U 25.02 1.08 iT 5.762 0.500 19.960 K Factor 5.60 to 120 0.0 5.762 0.0 B22 48.92 0.5909 0.0 6.262 3.700 Vet = 17.13 0.0 -- 48.92 23.660 K Factor= 10.06 *P12 B23P 23.53 1.08 1 2.305 2.780 21.608 to 120 0.0 2.305 -3.032 B23U 23.53 0.1526 0.0 5.085 0.776 Vel = 8.24 B23U 24.64 1.08 IT 5.762 0.500 19.352 K Factor = 5.60 to 120 0.0 5.762 0.0 B23 48.17 0.5741 0.0 6.262 3.595 Vel = 16.87 0.0 48.17 22.947 KFactor= 10.06 *P15 B24P 23.56 1.08 1E 2.305 3.470 21.651 to 120 0.0 2.305 -3.032 B24U 23.56 0.1529 0.0 5.775 0.883 Vel = 8.25 B24U 24.73 1.08 1 5.762 0.500 19.502 K Factor = 5.60 to 120 0.0 5.762 0.0 B24 48.29 0.5767 0.0 6.262 3.611 Vel = 16.91 0.0 48.29 23.113 K Factor = 10.04 *P1 8 A4 40.80 2.203 1E 6.819 21.640 36.518 to 120 2T 27.277 34.096 0.0 A3 40.8 0.0131 0.0 55.736 0.731 Vet = 3.43 0.0 40.80 37.249 KFactor = 6.69 *P2i A5 36.25 2.203 1 6.819 53.520 35.595 to 120 2T 27.277 34.096 0.0 A4 36.25 0.0105 0.0 87.616 0.923 Vet = 3.05 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 9 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Fe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn A4 -60.20 1.536 2E 10.108 109.140 36.518 to 120 0.0 10.108 0.0 B3.1 -23.95 -0.0284 0.0 119.248 -3.381 Vel = 4.15 B3.1 0.0 1.536 0.0 0.330 33.137 to 120 0.0 0.0 0.143 B3 -23.95 -0.0303 0.0 0.330 -0.010 Vel = 4.15 0.0 -23.95 33.270 KFactor= -4.15 *P24 B4 19.26 1.536 IT 10.108 0.330 34.135 to 120 0.0 10.108 -0.143 B4.1 19.26 0.0190 0.0 10.438 0.198 Vel = 3.33 B4.1 0.0 1.536 1E 5.054 58.960 34.190 to 120 IT 10.108 15.162 0.0 A5 19.26 0.0190 0.0 74.122 1.405 Vel = 3.33 A5 -36.24 2.203 IT 13.639 12.520 35.595 to 120 0.0 13.639 0.0 A6 -16.98 -0.0026 0.0 26.159 -0.068 Vel = 1.43 A6 2.41 1.536 1E 5.054 58.960 35.527 to 120 0.0 5.054 0.0 B5.1 -14.57 -0.0113 0.0 64.014 -0.724 Vel = 2.52 B5.1 0.0 1.536 IT 10.108 0.330 34.803 to 120 0.0 10.108 0.143 B5 -14.57 -0.0113 0.0 10.438 -0.118 Vel = 2.52 0.0 - -14.57 34.828 K Factor= -2.47 *P27 66 9.36 1.536 IT 10.108 0.330 35.356 to 120 0.0 10.108 -0.143 B6.1 - 9.36 0.0050 0.0 10.438 0.052 Vet = 1.62 B6.1 0.0 1.536 1E 5.054 36.240 35.265 to 120 IT 10.108 15.162 0.0 A7 9.36 0.0050 0.0 51.402 0.256 Vet = 1.62 A7 -2.41 1.536 IE 5.054 49.240 35.521 to 120 IT 10.108 15.162 0.0 B7.1 6.95 0.0029 0.0 64.402 0.186 Vet = 1.20 67.1 0.0 1.536 IT 10.108 0.330 35.707 to 120 0.0 10.108 0.143 B7 6.95 0.0029 0.0 10.438 0.030 Vet = 1.20 0.0 6.95 35.880 K Factor = 1.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 10 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *P30 BC 26.01 1.536 IT 10.108 0.330 43.065 to 120 0.0 10.108 -0.143 BC.1 26.01 0.0331 0.0 10.438 0.345 Vel = 4.50 BC.1 0.0 1.536 2T 20.216 176.820 43.267 to 120 0.0 20.216 0.0 AC.1 26.01 0.0330 0.0 197.036 6.511 Vel = 4.50 AC.1 0.0 1.536 IT 10.108 0.330 49.778 to 120 . 0.0 10.108 0.143 AC 26.01 0.0331 0.0 10.438 0.345 Vel = 4.50 0.0 26.01 50.266 K Factor= 3.67 *p.33 BB 26.42 1.536 IT 10.108 0.330 42.960 to 120 0.0 10.108 -0.143 BB.1 26.42 0.0340 0.0 10.438 0.355 Vel = 4.57 BB.1 0.0 1.536 2T 20.216 176.820 43.172 to 120 0.0 20.216 0.0 AB.1 26.42 0.0340 0.0 197.036 6.701 VeI= 4.57 AB.1 0.0 1.536 IT 10.108 0.330 49.873 to 120 0.0 10.108 0.143 AB 26.42 0.0340 0.0 10.438 0.355 Vel = 4.57 0.0 26.42 50.371 K Factor= 3.72 *P36 BA 26.72 1.536 2T 20.216 186.820 42.726 to 120 4E 20.216 40.432 0.0 AA 26.72 0.0347 0.0 227.252 7.888 Vel = 4.63 0.0 26.72 50.614 K Factor= 3.76 *p39 BlIP 23.82 1.08 IE 2.305 1.380 22.140 to 120 0.0 2.305 -3.032 B11U 23.82 0.1560 0.0 3.685 0.575 Vel = 8.34 B1IU 24.85 1.08 IT 5.762 0.500 19.683 K Factor = 5.60 to 120 0.0 5.762 0.0 Bli 48.67 0.5851 0.0 6.262 3.664 Vel = 17.05 0.0 48.67 23.347 KFactor= 10.07 *P42 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIIM FIRE PROTECTION CRP Page 11 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn B12P 22.68 1.08 1E 2.305 1.420 20.066 to 120 0.0 2.305 -3.032 B12U 22.68 0.1428 0.0 3.725 0.532 Vet = 7.94 B12U 23.47 1.08 IT 5.762 0.500 17.566 K Factor= 5.60 to 120 0.0 5.762 0.0 B12 46.15 0.5302 0.0 6.262 3.320 Vel= 16.16 0.0 46.15 20.886 KFactor= 10.10 *p45 B13P 22.50 1.08 IE 2.305 2.240 19.756 to 120 0.0 2.305 -3.032 B13U 22.5 0.1406 0.0 4.545 0.639 Vet = 7.88 B13U 23.33 1.08 IT 5.762 0.500 17.363 K Factor= 5.60 to 120 0.0 5.762 0.0 B13 45.83 0.5236 0.0 6.262 3.279 Vet = 16.05 0.0 45.83 20.642 K Factor= 10.09 *P48 B14P 22.68 1.08 1 2.305 3.060 20.067 to 120 0.0 2.305 -3.032 B14U 22.68 0.1426 0.0 5.365 0.765 Vet = 7.94 B14U 23.62 1.08 IT 5.762 0.500 17.800 K Factor= 5.60 to 120 0.0 5.762 0.0 B14 46.3 0.5335 0.0 6.262 3.341 Vel = 16.22 0.0 46.30 21.141 KFactor= 10.07 *P-51 B2 -82.02 1.536 IT 10.108 0.330 32.169 to 120 0.0 10.108 -0.143 B2.1 -82.02 -0.2765 0.0 10.438 -2.886 Vet = 14.20 B2.1 0.0 1.536 1E 5.054 14.770 29.140 to 120 0.0 5.054 0.0 B22 -82.02 -0.2764 0.0 19.824 -5.480 Vet = 14.20 B22 48.92 1.536 0.0 13.820 23.660 to 120 0.0 0.0 0.0 B23 -33.1 -0.0516 0.0 13.820 -0.713 Vel = 5.73 B23 48.17 1.536 0.0 13.820 22.947 to 120 0.0 0.0 0.0 B24 15.07 0.0120 0.0 13.820 0.166 Vet = 2.61 B24 48.29 1.536 0.0 82.430 23.113 to 120 0.0 0.0 0.0 A3 63.36 0.1715 0.0 82.430 14.136 Vel= 10.97 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 12 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn A3 40.79 1.536 1E 5.054 3.490 37.249 to 120 0.0 5.054 0.0 A2.1 104.15 0.4301 0.0 8.544 3.675 Vel = 18.03 A2.1 0.0 1.536 IT 10.108 0.330 40.924 to 120 0.0 10.108 0.143 A2 104.15 0.4302 0.0 10.438 4.490 Vel = 18.03 0.0 104.15 45.557 KFactor= 15.43 *p54 B8 -19.40 1.536 4E 20.216 177.656 40.854 to 120 2T 20.216 40.432 -0.147 A4 -19.4 -0.0192 0.0 218.088 -4.189 Vel = 3.36 0.0 -19.40 36.518 K Factor= -3.21 *p57 B9 22.73 1.536 4E 20.216 201.970 41.689 to 120 2T 20.216 40.432 0.0 A9 22.73 0.0257 0.0 242.402 6.241 Vel = 3.94 0.0 22.73 47.930 K Factor = 3.28 *P60 BO 25.93 1.536 2T 20.216 191.980 42.311 to 120 0.0 20.216 0.0 AU 25.93 0.0328 0.0 212.196 6.969 Vel = 4.49 0.0 25.93 49.280 K Factor = 3.69 *P63 Bi 113.35 2.703 0.0 12.540 31.767 to 120 0.0 0.0 0.0 B2 113.35 0.0321 0.0 12.540 0.402 VeI= 6.34 B2 82.02 2.703 0.0 12.540 32.169 to 120 0.0 0.0 0.0 B3 195.37 0.0878 0.0 12.540 1.101 Vel = 10.92 B3 -23.95 2.703 0.0 12.540 33.270 to 120 0.0 0.0 0.0 B4 171.42 0.0690 0.0 12.540 0.865 Vel = 9.58 B4 -19.26 2.703 0.0 12.520 34.135 to 120 0.0 0.0 0.0 B5 152.16 0.0554 0.0 12.520 0.693 Vet = 8.51 B5 -14.58 2.703 0.0 11.500 34.828 to 120 0.0 0.0 0.0 B6 137.58 0.0459 0.0 11.500 0.528 Vel = 7.69 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 13 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIFt Eqv. Ln. Total Pf Pn B6 -9.36 2.703 0.0 13.000 35.356 to 120 0.0 0.0 0.0 B7 128.22 0.0403 0.0 13.000 0.524 Vet = 7.17 B7 6.95 2.703 4E 37.301 74.560 35.880 to 120 0.0 37.301 0.004 B8 135.17 0.0444 0.0 111.861 4.970 Vel= 7.56 B8 19.40 2.703 0.0 14.660 40.854 to 120 0.0 0.0 0.0 B9 154.57 0.0570 0.0 14.660 0.835 Vet = 8.64 B9 -22.73 2.703 0.0 14.660 41.689 to 120 0.0 0.0 0.0 BO 131.84 0.0424 0.0 14.660 0.622 Vet = 7.37 BO -25.93 2.703 0.0 14.660 42.311 to 120 0.0 0.0 0.0 BA 105.91 0.0283 0.0 14.660 0.415 Vet = 5.92 BA -26.71 2.703 0.0 14.430 42.726 to 120 0.0 0.0 -0.004 BB 79.2 0.0165 0.0 14.430 0.238 Vet = 4.43 BB -26.43 2.703 0.0 13.490 42.960 to 120 0.0 0.0 0.0 BC 52.77 0.0078 0.0 13.490 0.105 Vet = 2.95 BC -26.01 2.703 2T 37.301 13.500 43.065 to 120 0.0 37.301 0.0 BD 26.76 0.0022 0.0 50.801 0.113 Vet = 1.50 BD 0.0 1.536 1E 5.054 0.330 43.178 to 120 0.0 5.054 -0.143 BD.1 26.76 0.0347 0.0 5.384 0.187 Vet = 4.63 BD.1 0.0 1.536 IT 10.108 176.820 43.222 to 120 0.0 10.108 0.0 AD.1 26.76 0.0348 0.0 186.928 6.508 Vet = 4.63 AD.1 0.0 1.536 IT 10.108 0.330 49.730 to 120 0.0 10.108 0.143 AD 26.76 0.0348 0.0 10.438 0.363 Vet = 4.63 AD 0.0 2.703 0.0 13.500 50.236 to 120 0.0 0.0 0.0 AC 26.76 0.0022 0.0 13.500 0.030 Vet = 1.50 AC 26.01 2.703 0.0 13.500 50.266 to 120 0.0 0.0 0.0 AB 52.77 0.0078 0.0 13.500 0.105 Vet = 2.95 AB 26.43 2.703 0.0 14.430 50.371 to 120 0.0 0.0 0.004 AA 79.2 0.0166 0.0 14.430 0.239 Vet = 4.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 14 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn AA 26.71 2.703 2E 18.651 22.290 50.614 to 120 iT 18.651 37.302 0.0 A 105.91 0.0283 0.0 59.592 1.686 Vel = 5.92 0.0 105.91 52.300 K Factor = 14.64 *P66 Bi -113.35 1.536 iT 10.108 0.330 31.767 to 120 0.0 10.108 -0.143 B1.1 -113.35 -0.5031 0.0 10.438 -5.251 Vel = 19.63 B1.1 0.0 1.536 1E 5.054 0.960 26.373 to 120 0.0 5.054 0.0 Bli -113.35 -0.5032 0.0 6.014 -3.026 Vet = 19.63 Bli 48.66 1.536 0.0 13.810 23.347 to 120 0.0 0.0 0.0 B12 -64.69 -0.1782 0.0 13.810 -2.461 Vet = 11.20 B12 46.15 1.536 0.0 13.820 20.886 to 120 0.0 0.0 0.0 B13 -18.54 -0.0177 0.0 13.820 -0.244 Vel = 3.21 B13 45.83 1.536 0.0 13.820 20.642 to 120 0.0 0.0 0.0 B14 - 27.29 0.0361 0.0 13.820 0.499 Vet = 4.73 B14 46.31 1.536 iT 10.108 85.930 21.141 to 120 0.0 10.108 0.0 A1.1 73.6 0.2263 0.0 96.038 21.731 Vet = 12.74 A1.1 0.0 1.536 iT 10.108 0.330 42.872 to 120 0.0 10.108 0.147 Al 73.6 0.2263 0.0 10.438 2.362 Vel = 12.74 Al 0.0 2.703 0.0 12.540 45.381 to 120 0.0 0.0 -0.004 A2 73.6 0.0144 0.0 12.540 0.180 Vel= 4.12 A2 104.15 2.703 IE 9.325 8.130 45.557 to 120 0.0 9.325 0.004 A8 177.75 0.0738 0.0 17.455 1.288 Vel = 9.94 A8 0.0 2.703 0.0 14.660 46.849 to 120 0.0 0.0 0.0 A9 177.75 0.0737 0.0 14.660 1.081 Vet = 9.94 A9 22.73 2.703 0.0 14.660 47.930 to 120 0.0 0.0 0.0 AO 200.48 0.0921 0.0 14.660 1.350 Vet = 11.21 AO 25.93 2.703 iT 18.651 7.520 49.280 to 120 0.0 18.651 0.0 A 226.41 0.1154 0.0 26.171 3.020 VeI= 12.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 15 TRI-CITY WELLNESS CENTER Date 021908 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn A 105.91 3.314 3E 30.574 34.470 52.300 to 120 0.0 30.574 13.712 BORA 332.32 0.0870 0.0 65.044 5.658 Vet = 12.36 BORA 0.0 5.86 6E 107.359 115.000 71.670 to 150 1 38.342 145.701 2.736 * Fixed loss = 2.736 UG1 332.32 0.0036 iZaf 0.0 260.701 0.934 - Vel = 3.95 UG1 0.0 7.68 0.0 55.000 75.340 to 150 0.0 0.0 0.0 HOSE 332.32 0.0010 0.0 55.000 0.053 Vet = 2.30 HOSE 100.00 7.68 4E 90.221 515.000 75.393 Qa = 100 to 150 IT 43.857 134.078 0.0 TEST 432.32 0.0016 0.0 649.078 1.015 Vel = 2.99 0.0 432.32 - 76.408 KFactor= 49.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP 101 COPPERWOOD WAY SUITE F OCEANSIDE, CA 92058 760-722-2722 Job Name : TRI-CITY BUILDING B Building : B Location 6250 EL CAMINO REAL, CARLSBAD, CA System 1 Contract : 08-001 Data File : BLDG B.wxl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Page 1 TRI-CITY BUILDING B Date 022808 Hydraulic Design Information Sheet Name - TRI-CITY WELLNESS COMPLEX Date - 02-21-08 Location - 6250 EL C/AMINO REAL, CARLSBAD, CA Building - B System No. - 1 Contractor - MILLENNIUM FIRE PROTECTION Contract No. - 08-001 Calculated By - RDH Drawing No. - 1 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - VARIES Occupancy - MEDICAL OFFICE BUILDING S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make TYCO D Area Per Sprinkler - 225.00 ( ) Dry Model TY3131 E Elevation at Highest Outlet 32.500 ( ) Deluge Size 1/2' S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200° G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 207.9 Press Required - 63.74 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 02-02-08 Cap. - T Time of Test - 10:12/AM Rated Cap.- Elev.- E Static Press - 92 8 Press - R Residual Press - 85 Elev. - Well Flow - 1450 Proof Flow S Elevation - 0 U P Location - TOWN GARDEN AND EL C/AMINO REAL P L Source of Information - MILLENNIUM FIRE PROTECTION AND CARLSBAD FIRE DEP. Y C Commodity 0 Storage Ht. M Storage Method: M Single Row S P. ( ) Double Row TA Mult. Row 0 C R K Flue Spacing A Longitudinal G E Horizontal Barr Class Area Solid Piled % Conven. Pallet Slave Pallet Location Aisle W. Palletized % Rack Auto. Storage ( ) Encap. Solid Shelf ( ) Non Open Shelf Clearance:Storage to Ceiling Transverse s Pro Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Page 2 TRI-CITY BUILDING B Date 022808 City Water Supply: Demand: C1- Static Pressure : 92 Dl - Elevation : 14.076 C2 - Residual Pressure: 85 D2 - System Flow : 207.901 tem Pressure : 63.739 C2 - Residual Flow : 1450 D2 - SrSAd j Hose City) Hose Demand) D3 - System Demand : 307.901 Safety Margin : 27.862 150 140 130 p 120 R110 E 100 : S90 S80 ___ ______ ________ C2 - o Perceni Under u70 D: R6° E5° 40 30 20 10 - 4)4-- 200 400600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram MILLENNIUM FIRE PROTECTION CRP TRI-CITY BUILDING B 48.2 2.9 Cl -* 014-+ D13 -+D12+- Dl 1' 25.4 19. 48.2 I 42.4 39.3 6.9 C2 _ D24- D23- D22- D2 1' 16.1 301' 87.5 95.5 I 25.7 C3----------------- 1' t 113.3 I 94.6 I 21 I C4 --------- -..- -D4 1' 1' 134.3 I 73.6 17.7 I CS D5 1' 152 207.9 BORE UG2- TEST 307.9 Page 3 Date 022808 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 4 TRI-CITY BUILDING B Date 022808 Fitting Legend Abbrev. Name 1/2 % 1 1% 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 T 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD MILLENNIUM FIRE PROTECTION CRP Page 5 TRI-CITY BUILDING B Date 022808 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. D21 32.5 5.6 17.13 na 23.18 0.1 225 7.0 C2 32.5 23.49 na D24 32.5 5.6 17.11 na 23.17 0.1 225 7.0 D23 32.5 5.6 16.93 na 23.04 0.1 225 7.0 D22 32.5 5.6 16.97 na 23.07 0.1 225 7.0 C3 32.5 24.17 na D31 32.5 5.6 19.7 na 24.86 0.1 225 7.0 .C4 32.5 25.13 na 05 32.5 26.65 na D7 32.5 25.33 na D6 32.5 25.03 na Dl 32.5 16.85 na D12 32.5 5.6 16.14 na 22.5 0.1 225 7.0 D13 32.5 5.6 16.15 na 22.51 0.1 225 7.0 D14 32.5 5.6 16.57 na 22.8 0.1 225 7.0 Cl 32.5 23.26 na Dli 32.5 5.6 16.56 na 22.79 0.1 225 7.0 D2 32.5 17.43 na D3 32.5 20.04 na D4 32.5 22.29 na D5 32.5 23.92 na D8 32.5 25.61 na 08 32.5 26.99 na 07 32.5 27.15 na 06 32.5 27.44 na C 32.5 29.17 na BORB 0.0 59.86 na UG2 0.0 63.27 na 100.0 TEST 0.0 63.74 na The maximum velocity is 17.5 and it occurs in the pipe between nodes C and BORB Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 7 TRI-CITY BUILDING B Date 022808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C5 -17.65 1.536 3E 15.162 123.960 26.648 to 120 3T 30.324 45.486 0.0 D5 -17.65 -0.0161 0.0 169.446 -2.732 Vel = 3.06 0.0 -17.65 23.916 KFactor -3.61 *P24 D7 16.53 1.536 2T 20.216 107.240 25.325 to 120 0.0 20.216 0.0 C7 16.53 0.0143 0.0 127.456 1.820 Vet = 2.86 0.0 16.53 27.145 K Factor = 3.17 *P27 D6 19.27 1.536 2T 20.216 107.240 25.027 to 120 0.0 20.216 0.0 06 19.27 0.0190 0.0 127.456 2.417 Vel = 3.34 0.0 19.27 27.444 KFactor = 3.68 *P30 Dl -19.58 1.536 IT 10.108 25.976 16.848 to 120 0.0 10.108 0.0 D12 - -19.58 -0.0195 0.0 36.084 -0.705 Vet = 3.39 D12 22.50 1.536 0.0 13.370 16.143 K Factor= 5.60 to 120 0.0 0.0 0.0 D13 2.92 0.0006 0.0 13.370 0.008 Vet = 0.51 D13 22.51 1.536 0.0 13.370 16.151 K Factor= 5.60 to 120 0.0 0.0 0.0 D14 25.43 0.0316 0.0 13.370 0.423 Vet = 4.40 D14 22.80 1.536 iT 10.108 54.514 16.574 K Factor =5.60 to 120 0.0 10.108 0.0 Cl 48.23 0.1035 0.0 64.622 6.690 Vel = 8.35 Cl 0.0 2.203 0.0 12.660 23.264 to 120 0.0 0.0 0.0 02 48.23 . 0.0179 0.0 12.660 0.227 Vet = 4.06 02 39.31 2.203 0.0 12.660 23.491 to 120 0.0 0.0 0.0 03 87.54 0.0538 0.0 12.660 0.681 Vet = 7.37 03 25.74 2.203 0.0 11.080 24.172 to 120 0.0 0.0 0.0 C4 113.28 0.0868 0.0 11.080 0.962 Vet = 9.53 04 21.03 2.203 0.0 12.740 25.134 to 120 0.0 0.0 0.0 C5 134.31 0.1188 0.0 12.740 1.514 Vet = 11.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIUM FIRE PROTECTION CRP Page 8 TRI-CITY BUILDING B Date 022808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C5 17.65 2.203 iT 13.639 3.250 26.648 to 120 0.0 13.639 0.0 C 151.96 0.1494 0.0 16.889 2.524 Vel = 12.79 0.0 151.96 29.172 KFactor= 28.13 *33 Dii 22.79 1.536 iT 10.108 1.060 16.559 K Factor= 5.60 to 120 0.0 10.108 0.0 Dl 22.79 0.0259 0.0 11.168 0.289 Vel = 3.95 Dl 19.57 1.728 0.0 12.660 16.848 to 120 0.0 0.0 0.0 D2 42.36 0.0459 0.0 12.660 0.581 Vel = 5.80 D2 53.15 1.728 0.0 12.660 17.429 to 120 0.0 0.0 0.0 D3 95.51 0.2065 0.0 12.660 2.614 Vel = 13.07 D3 -0.88 1.728 0.0 11.080 20.043 to 120 0.0 0.0 0.0 D4 94.63 0.2030 0.0 11.080 2.249 Vel = 12.95 D4 -21.04 1.728 0.0 12.740 22.292 to 120 0.0 0.0 0.0 05 73.59 0.1275 0.0 12.740 1.624 Vel = 10.07 D5 -17.65 1.728 0.0 14.470 23.916 to 120 0.0 0.0 0.0 D6 55.94 0.0768 0.0 14.470 1.111 VeI= 7.65 D6 -19.27 1.728 0.0 8.500 25.027 to 120 0.0 0.0 0.0 D7 36.67 0.0351 0.0 8.500 0.298 Vel = 5.02 D7 -16.53 1.728 ii 11.29 13.580 25.325 to 120 0.0 11.290 0.0 D8 20.14 0.0116 0.0 24.870 0.289 Vel = 2.76 D8 0.0 1.728 iT 11.29 107.240 25.614 to 120 0.0 11.290 0.0 08 20.14 0.0116 0.0 118.530 1.374 Vel = 2.76 C8 0.0 1.728 0.0 13.580 26.988 to 120 0.0 0.0 0.0 C7 20.14 0.0116 0.0 13.580 0.157 Vel = 2.76 C7 16.53 1.728 0.0 8.500 27.145 to 120 0.0 0.0 0.0 C6 36.67 0.0352 0.0 8.500 0.299 Vel = 5.02 C6 19.27 1.728 iT 11.29 11.220 27.444 to 120 0.0 11.290 0.0 C 55.94 0.0768 0.0 22.510 1.728 Vel = 7.65 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 6 TRI-CITY BUILDING B Date 022808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt PfIFt Eqv. Ln. Total Pt Pn *P6 021 23.18 1.536 iT 10.108 1.060 17.131 K Factor = 5.60 to 120 0.0 10.108 0.0 D2 23.18 0.0267 0.0 11.168 0.298 VeI= 4.01 0.0 23.18 17.429 K Factor = 5.55 *P-9 C2 -39.31 1.536 iT 10.108 79.846 23.491 to 120 0.0 10.108 0.0 D24 -39.31 -0.0709 0.0 89.954 -6.379 Vel = 6.81 D24 23.17 1.536 0.0 13.370 17.112 K Factor = 5.60 to 120 0.0 0.0 0.0 D23 -16.14 -0.0137 0.0 13.370-0.183 Vet = 2.79 D23 23.04 1.536 0.0 13.370 16.929 K Factor =5.60 to 120 0.0 0.0 0.0 022 6.9 0.0028 0.0 13.370 0.038 Vel = 1.19 D22 23.07 1.536 IT 10.108 0.644 16.967 K Factor =5.60 to 120 0.0 10.108 0.0 D2 29.97 0.0430 0.0 10.752 0.462 Vet = 5.19 0.0 29.97 17.429 K Factor = 7.18 *P12 C3 -25.74 1.536 2T 20.216 107.240 24.172 to 120 0.0 20.216 0.0 D3 -25.74 -0.0324 0.0 127.456 -4.129 Vel = 4.46 0.0 -25.74 20.043 K Factor= -5.75 *P15 031 24.86 1.536 iT 10.108 1.060 19.704 K Factor 5.60 to 120 0.0 10.108 0.0 D3 24.86 0.0304 0.0 11.168 0.339 Vel = 4.30 0.0 24.86 20.043 K Factor = 5.55 *P18 04 -21.03 1.536 2T 20.216 107.240 25.134 to 120 0.0 20.216 0.0 04 -21.03 -00223 0.0 127.456 -2.842 Vet = 3.64 0.0 -21.03 22.292 KFactor= -4.45 *P2i Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Standard MILLENNIU*M FIRE PROTECTION CRP Page 9 TRI-CITY BUILDING B Date 022808 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn C 151.96 2.203 3E 20.458 41.820 29.172 - to 120 0.0 20.458 14.076 BORB 207.9 0.2668 0.0 62.278 16.616 Vel = 17.50 BORB 0.0 5.86 6E 107.359 170.000 59.864 to 150 iZaf 0.0 107.359 2.984 * Fixed loss = 2.984 UG2 207.9 0.0015 0.0 277.359 0.418 VeI= 2.47 UG2 100.00 7.68 3E 67.666 500.000 63.266 Qa = 100 to 150 0.0 67.666 0.0 TEST 307.9 0.0008 0.0 567.666 0.473 Vel = 2.13 0.0 307.90 63.739 K Factor = 38.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP 101 COPPERW000 WAY SUITE F OCEANSIDE, CA 92058 760-722-2722 Job Name : TRI-CITY BLDGA Fl Building : A Location : 6250 EL CAMINO REAL, CARLSBAD, CA System 1 Contract : 08-001 Data File : BLDG A 1FL.wxl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 MILLENNIUM FIRE PROTECTION CRP Page 1 TRI-CITY BLDGA Fl Date 040208 Hydraulic Design Information Sheet Name - TRI-CITY WELLNESS COMPLEX Date - 02-21-08 Location - 6250 EL CANINO REAL, CARLSBAD, CA Building - A System No. - 1 Contractor - MILLENNIUM FIRE PROTECTION Contract No. - 08-001 Calculated By - RDH Drawing No. - 1 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - VARIES Occupancy - FITNESS CENTER S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E N Area of Sprinkler Operation - 922.5 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make TYCO D Area Per Sprinkler - 400.00 ( ) Dry Model TY4232 B Elevation at Highest Outlet - 11 ( ) Deluge Size 3/4" S Hose Allowance - Inside - ( ) Preaction K-Factor 8.0 I Rack Sprinkler Allowance - ( ) Other Ternp.Rat.1550 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 201.63 Press Required - 78.77 Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 02-02-08 Cap. - T Time of Test - 10:12AM Rated Cap.- Elev.- E Static Press - 92 @ Press - R Residual Press - 85 Elev. - Well Flow - 1450 Proof Flow S Elevation - 0 U P Location - TOWN GARDEN AND EL CAMINO REAL P L Source of Information - MILLENNIUM FIRE PROTECTION AND CARLSBAD FIRE DEP. Y C Commodity Class Location 0 Storage Ht. Area Aisle W. N Storage Method: Solid Piled % Palletized % Rack N Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. SR Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non TA Nult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse 0 E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve (C) MILLENNIUM FIRE PROTECTION CRP Page 2 TRI-CITY BLDGA Fl Date 040208 City Water Supply Demand: 'Cl - Static Pressure : 92 Dl - Elevation : 4.331 C2 - Residual Pressure: 85 D2 - System Flow : 201.628 e Pessure : 78.768 02 - Residual Flow : 1450 D2 - S~A"djrCit~rl) ) Hose Hose Deman : 100 D3 - System Demand : 301.628 Safety Margin : 12.849 150 140 - 130 - P 120 R11° E 100 S 90 ----------- - - C2 —e----------___ S80 ercen Under u70 3 R6° E5° 40 30 20 10 .,.... .. . 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram MILLENNIUM FIRE PROTECTION CRP TRI.-CITY BLDGA Fl 5.1 F6 -* E5 1' 14.8 I 23.5 F5 - F41 201.6 301.6 B0P44 UG1- HOS TEST 201.6 Page 3 Date 040208 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary MILLENNIUM FIRE PROTECTION CRP Page 4 TRI-CITY BLDGA Fl Date 040208 - Fitting Legend Abbrev. Name 1/z 1 11/4 1½ 2 2½ 3 31/2 4 5 6 8 10 12 14 16 18 20 24- E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 1 90' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD MILLENNIUM FIRE PROTECTION CRP Page 5 TRI-CITY BLDGA Fl Date 040208 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 0.1 400 25.0 0.1 400 25.0 D201 14.0 8 25.0 na 40.0 D202 14.0 8 25.0 na 40.0 ED1P 11.0 K= K@ EQ01 46.5 na 40.17 F7 13.583 61.8 na F6 13.583 62.02 na F5 13.583 62.36 na F4 13.583 63.19 na F3 13.583 63.29 na E6 13.583 61.75 na F41 13.583 63.14 na E8 13.583 60.1 na E9 13.583 59.84 na EQ 13.583 59.34 na EE2 10.0 K = K @ EQ01 47.61 na 40.64 ED 13.583 54.89 na ED1 13.583 48.0 na ED2P 11.0 K = K @ EQ01 46.27 na 40.07 ED2 13.583 46.34 na EC 13.583 55.1 na EC2P 10.0 K= K@ EQ01 46.11 na 40.0 EC2 13.583 46.88 na EB 13.583 57.05 na EA 13.583 58.63 na EE 13.583 54.74 na E7 13.583 61.62 na E5 13.583 61.88 na E4 13.583 62.01 na E3 13.583 62.08 na E2 13.583 62.11 na El 13.583 62.14 na Fl 13.583 65.16 na F2 13.583 65.17 na F8 13.583 65.5 na F9 13.583 65.77 na FO 13.583 66.26 na EEl 10.0 K = K @ EQ02 49.31 na 40.75 FE 13.583 47.76 na FD 13.583 48.0 na FC 13.583 48.53 na FBi 13.583 50.05 na FB 13.583 67.31 na FA 13.583 67.37 na F 13.583 67.65 na 1FRA 0.0 74.0 na BORA 0.0 74.86 na UG1 0.0 78.23 na HOSE 0.0 78.25 na 100.0 TEST 0.0 78.77 na The maximum velocity is 14.91 and it occurs in the pipe between nodes ED1P and ED1 Computer Programs by Hydratec Inc. Route 111 Windham N. H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 6 TRI-CITY BLDGA Fl Date 040208 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D201 40.00 1.049 1E 2.0 43.000 25.000 K Factor = 8.00 to 120 0.0 2.000 0.0 EQ01 40.0 0.4691 0.0 45.000 21.111 Vel = 14.85 0.0 40.00 46.111 K Factor = 5.89 D202 40.00 1.049 1 5.0 43.000 25.000 K Factor= 8.00 to 120 0.0 5.000 0.0 EQ02 40.0 0.4691 0.0 48.000 22.518 Vel = 14.85 0.0 40.00 47.518 KFactor= 5.80 *P6 ED1P 40.17 1.049 1 5.0 0.540 46.504 K Factor@ node EQOI to 120 0.0 5.000 -1.119 ED1 40.17 0.4727 0.0 5.540 2.619 Vel = 14.91 0.0 - 40.17 48.004 KFactor= 5.80 *P-9 F7 -5.89 1.442 1 3.716 45.580 61.801 to 120 2T 14.864 18.580 0.0 E7 -5.89 -0.0029 0.0 64.160 -0.184 Vel = 1.16 0.0 -5.89 61.617 KFactor= -0.75 *P12 F6 -5.09 1.442 2T 14.864 50.500 62.022 to 120 0.0 14.864 0.0 E5 -5.09 -0.0022 0.0 65.364 -0.144 Vel = 1.00 0.0 -5.09 61.878 KFactor -0.65 *P15 F5 -8.76 1.442 iT 7.432 50.540 62.359 to 120 0.0 7.432 0.0 E4 -8.76 -0.0060 0.0 57.972 -0.348 Vel = 1.72 0.0 -8.76 62.011 K Factor = -1.11 *P18 F4 -13.91 1.442 2T 14.864 64.080 63.193 to 120 0.0 14.864 0.0 E3 -13.91 -0.0141 0.0 78.944 -1.115 Vel= 2.73 0.0 -13.91 62.078 KFactor= -1.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 7 TRI-CITY BLDGA Fl Date 040208 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn *P21 F3 -14.39 1.442 2T 14.864 64.080 63.292 to 120 0.0 14.864 0.0 E2 -14.39 -0.0150 0.0 78.944 -1.185 Vet = 2.83 0.0 -14.39 62.107 K Factor -1.83 *P24 E6 3.78 1.442 iT 7.432 35.200 61.747 to 120 0.0 7.432 0.0 F7 3.78 0.0013 0.0 42.632 0.054 Vel = 0.74 F7 5.88 1.442 IE 3.716 26.910 61.801 to 120 0.0 3.716 0.0 F6 9.66 0.0072 0.0 30.626 0.221 Vet = 1.90 F6 5.10 1.442 IT 7.432 14.000 62.022 to 120 0.0 7.432 0.0 F5 14.76 0.0157 0.0 21.432 0.337 Vel = 2.90 F5 8.76 1.442 iT 7.432 13.580 62.359 to 120 0.0 7.432 0.0 F41 23.52 0.0373 0.0 21.012 0.783 Vel = 4.62 F41 0.0 2.157 0.0 9.660 63.142 to 120 0.0 0.0 0.0 F4 23.52 0.0053 0.0 9.660 0.051 Vel = 2.07 F4 13.91 2.157 0.0 8.000 63.193 to 120 0.0 0.0 0.0 F3 37.43 0.0124 0.0 8.000 0.099 Vet = 3.29 F3 14.39 2.157 1 6.153 64.540 63.292 to 120 IT 12.307 18.460 0.0 F2 51.82 0.0226 0.0 83.000 1.878 Vet = 4.55 0.0 51.82 65.170 K Factor = 6.42 *P27 E8 19.50 1.442 2T 14.864 189.830 60.103 to 120 0.0 14.864 0.0 F8 19.5 0.0264 0.0 204.694 5.398 Vet = 3.83 0.0 19.50 65.501 K Factor = 2.41 *P30 E9 20.53 1.442 2T 14.864 189.700 59.837 to 120 0.0 14.864 0.0 F9 20.53 0.0290 0.0 204.564 5.931 Vet = 4.03 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 8 TRI-CITY BLDGA Fl Date 040208 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 20.53 65.768 K Factor = 2.53 *p33 EO 21.11 1.442 4E 14.864 196.750 59.343 to 120 2T 14.864 29.728 0.0 FO 21.11 0.0305 0.0 226.478 6.918 Vel = 4.15 0.0 21.11 66.261 K Factor = 2.59 *P36 EE2 40.64 1.38 IT 6.0 7.370 47.608 K Factor @ node EQ01 to 120 0.0 6.000 -1.552 FE 40.64 0.1271 0.0 13.370 1.699 Vel = 8.72 0.0 40.64 47.755 K Factor = 5.88 *p39 ED -41.84 1.442 IT 7.432 56.120 54.885 to 120 0.0 7.432 0.0 ED1 -41.84 -0.1083 0.0 63.552 -6.881 Vel = 8.22 ED1 40.17 1.442 IT 7.432 12.620 48.004 to 120 0.0 7.432 0.0 FD -1.67 -0.0003 0.0 20.052 -0.006 Vel = 0.33 0.0 -1.67 47.998 K Factor = -0.24 *P42 ED2P 40.07 1.049 1E 2.0 0.540 46.267 K Factor @ node EQ01 to 120 0.0 2.000 -1.119 ED2 40.07 0.4709 0.0 2.540 1.196 Vel = 14.88 ED2 0.0 1.38 1T 6.0 7.370 46.344 to 120 0.0 6.000 0.0 FD 40.07 0.1237 0.0 13.370 1.654 Vel = 8.60 0.0 40.07 47.998 K Factor = 5.78 *p45 EC -35.18 1.442 2T 14.864 68.750 55.098 to 120 0.0 14.864 0.0 FC -35.18 -0.0785 0.0 83.614 -6.567 Vel = 6.91 0.0 -35.18 48.531 K Factor -5.05 *P48 EC2P 40.00 1.049 1E 2.0 2.950 46.111 K Factor @ node EQ01 to 120 0.0 2.000 -1.552 EC2 40.0 0.4691 0.0 4.950 2.322 Vel = 14.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 9 TRI-CITY BLDGA Fl Date 040208 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EC2 0.0 1.38 iT 6.0 7.370 46.881 to 120 0.0 6.000 0.0 FC 40.0 0.1234 0.0 13.370 1.650 Vel = 8.58 0.0 40.00 48.531 K Factor = 5.74 *P51 EB -37.25 1.442 1 3.716 69.120 57.055 to 120 iT 7.432 11.148 0.0 FBi -37.25 -0.0873 0.0 80.268 -7.010 Vel = 7.32 0.0 -37.25 50.045 K Factor= -5.27 *p54 EA 23.66 1.442 3E 11.148 198.250 58.630 to 120 3T 22.296 33.444 0.0 FA 23.66 0.0377 0.0 231.694 8.738 Vel = 4.65 0.0 23.66 67.368 K Factor = 2.88 *p..57 EE 40.32 2.635 iT 16.474 11.000 54.738 to 120 0.0 16.474 0.0 ED 40.32 0.0054 0.0 27.474 0.147 Vel = 2.37 ED 41.84 2.635 0.0 10.660 54.885 to 120 0.0 0.0 0.0 EC 82.16 0.0200 0.0 10.660 0.213 Vel = 4.83 EC 35.18 2.635 2E 16.474 17.580 55.098 to 120 iT 16.474 32.948 0.0 EB 117.34 0.0387 0.0 50.528 1.957 Vel = 6.90 EB 37.25 2.635 iT 16.474 7.950 57.055 to 120 0.0 16.474 0.0 EA 154.59 0.0645 0.0 24.424 1.575 VeI= 9.10 EA -23.66 2.635 0.0 15.040 58.630 to 120 0.0 0.0 0.0 EO 130.93 0.0474 0.0 15.040 0.713 Vel = 7.70 EO -21.11 2.635 0.0 14.410 59.343 to 120 0.0 0.0 0.0 E9 109.82 0.0343 0.0 14.410 0.494 Vel = 6.46 E9 -20.53 2.635 0.0 11.410 59.837 to 120 0.0 0.0 0.0 E8 89.29 0.0233 0.0 11.410 0.266 Vel = 5.25 E8 -19.50 2.635 2E 16.474 85.750 60.103 to 120 0.0 16.474 0.0 E7 69.79 0.0148 0.0 102.224 1.514 Vel = 4.11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MILLENNIUM FIRE PROTECTION CRP Page 10 TRI-CITY BLDGA Fl Date 040208 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn E7 -5.89 2.635 0.0 10.370 61.617 to 120 0.0 0.0 0.0 E6 63.9 0.0125 0.0 10.370 0.130 Vel = 3.76 E6 -3.78 2.635 0.0 11.620 61.747 to 120 0.0 0.0 0.0 E5 60.12 0.0113 0.0 11.620 0.131 Vel = 3.54 E5 -5.09 2.635 0.0 14.000 61.878 to 120 0.0 0.0 0.0 E4 55.03 0.0095 0.0 14.000 0.133 Vel = 3.24 E4 -8.76 2.635 0.0 9.660 62.011 to 120 0.0 0.0 0.0 E3 46.27 0.0069 0.0 9.660 0.067 Vel = 2.72 E3 -13.91 2.635 0.0 7.950 62.078 to 120 0.0 0.0 0.0 E2 32.36 0.0036 0.0 7.950 0.029 Vel = 1.90 E2 -14.39 2.635 iT 16.474 8.040 62.107 to 120 0.0 16.474 0.0 El 17.97 0.0012 0.0 24.514 0.029 Vel = 1.06 El 0.0 1.442 IT 7.432 126.080 62.136 to 120 0.0 7.432 0.0 Fl 17.97 0.0227 0.0 133.512 3.028 Vel = 3.53 Fl 0.0 2.635 0.0 5.500 65.164 to 120 0.0 0.0 0.0 F2 17.97 0.0011 0.0 5.500 0.006 Vel= 1.06 F2 51.82 2.635 1E 8.237 14.120 65.170 to 120 0.0 8.237 0.0 F8 69.79 0.0148 0.0 22.357 0.331 Vel= 4.11 F8 19.50 2.635 0.0 11.410 65.501 to 120 0.0 0.0 0.0 F9 89.29 0.0234 0.0 11.410 0.267 Vel = 5.25 F9 20.53 2.635 0.0 14.410 65.768 to 120 0.0 0.0 0.0 FO 109.82 0.0342 0.0 14.410 0.493 Vel = 6.46 FO 21.11 2.635 IT 16.474 12.830 66.261 to 120 0.0 16.474 0.0 F 130.93 0.0474 0.0 29.304 1.390 Vel = 7.70 0.0 130.93 67.651 KFactor= 15.92 *P60 EE -40.32 1.442 2E 7.432 61.660 54.738 to 120 0.0 7.432 1.552 EEl -40.32 -0.1011 0.0 69.092 -6.984 Vel= 7.92 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams MtLtENNI1iM FIRE PROTECTION CRP Page 11 TRI-CITY BLDGA Fl Date 040208 Hyd. Ref. Qa Dia. "C" Fitting or Pipe Ftng's Pt Pt Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn EEl 40.75 1.442 iT 7.432 12.620 49.306 K Factor @ node EQ02 to 120 0.0 7.432 -1.552 FE 0.43 0.0 0.0 20.052 0.001 VeI = 008 __ FE 40.64 2.157 0.0 16.540 47.755 to 120 0.0 0.0 0.0 FD 41.07 0.0147 0.0 16.540 0.243 Vet = 3.61 FD 38.40 2.157 0.0 10.660 47.998 to 120 0.0 0.0 0.0 FC 79.47 0.0500 0.0 10.660 0.533 Vet = 6.98 FC 4.82 2.157 IT 12.307 14.910 48.531 to 120 0.0 12.307 0.0 FBi 84.29 0.0556 0.0 27.217 1.514 Vet = 7.40 FBi -37.26 1.442 IT 7.432 121.000 50.045 to 120 0.0 7.432 0.0 FB 47.03 0.1344 0.0 128.432 17.264 Vet = 9.24 FB 0.0 2.635 0.0 8.290 67.309 to 120 0.0 0.0 0.0 FA 47.03 0.0071 0.0 8.290 0.059 Vet = 2.77 FA 23.67 2.635 iT 16.474 2.200 67.368 to 120 0.0 16.474 0.0 F 70.7 0.0152 0.0 18.674 0.283 Vet = 4.16 F 130.93 3.26 1E 9.408 3.040 67.651 to 120 0.0 9.408 5.883 1FRA 201.63 0.0374 0.0 12.448 0.465 Vet = 7.75 1FRA 0.0 3.26 1E 9.408 13.580 73.999 to 120 0.0 9.408 0.0 BORA 201.63 0.0374 0.0 22.988 0.859 Vet = 7.75 BORA 0.0 5.86 6E 107.359 115.000 74.858 to 150 iT 38.342 145.701 2.996 * Fixed toss = 2.996 UGI 201.63 0.0014 iZaf 0.0 260.701 0.371 Vet = 2.40 UGI 0.0 7.68 0.0 55.000 78.225 to 150 0.0 0.0 0.0 HOSE 201.63 0.0004 0.0 55.000 0.021 Vet = 1.40 HOSE 100.00 7.68 4E 90.221 515.000 78.246 Qa = 100 to 150 iT 43.857 134.078 0.0 TEST 301.63 0.0008 0.0 649.078 0.522 Vet = 2.09 0.0 301.63 78.768 KFactor= 33.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ES-A-3000SS Series 3000SS A AMES Double Check Detector Assemblies Sizes: 21/2 - 12" (65— 300mm) 3000SS Features Patented Cam Check Assembly valve -i provides low head loss f Short lay length is ideally suited for ' I retrofit installations - Stainless Steel body is half the weight of competitive designs reducing installation and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Series 3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to grooved style coupling for ease of maintenance prevent the reverse flow of fire protection system substances, i.e., glycerin wetting No special tools required for servicing agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water supply. Compact construction allows for smaller vaults and enclosures Furnished with %" x %" bronze meter Specifications (gpm or cfm) A Double Check Detector Assembly shall be installed on fire protection systems when Detects underground leaks and connected to a potable water supply. Degree of hazard present is determined by the unauthorized water use local authority having jurisdiction. The main valve body shall be manufactured from Maybe installed horizontal or vertical 300 Series stainless steel to provide corrosion resistance, 100% lead free through the "flow up" position waterway. The double check detector assembly consists of two independently operating, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass Available Models assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check Suffix including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam-check LG - less shutoff valves includes a stainless steel cam arm and spring, rubber faced disc and a replaceable osv - ULJFM outside stem and yoke seat. There shall be no brass or bronze parts used within the cam-check valve resilient seated gate valves assembly. The check valve seats shall be of molded thermoplastic construction. The "OSY FxG - flanged inlet gate connection and use of seat screws as a retention method is prohibited. All internal parts shall be grooved outlet gate connection accessible through a single cover on the valve assembly. The valve cover shall be held Qy GxF -grooved inlet gate connection in place through the use of a single grooved style two-bolt coupling. The bypass line and flanged outlet gate connec- shall be hydraulically sized to accurately measure low flow. The bypass line shall con- tion sist of a meter, a small diameter double check assembly with test cocks and isolation "OSY GxG - grooved inlet gate connection and valves. The bypass line double check valve shall have a single access cover, two grooved outlet gate connection independently operating modular poppet check valves, and top mounted test cocks. CFM - cubic feet per minute The assembly shall be an Ames 3000SS. GPM - gallons per minute meter Available with grooved NRS gate valves - Materials consult factory" All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless Post indicator plate and operating nut steel, Check assembly: Noryl® Flange dimension in accordance with AWINA Class D. available - consult factory* Noryim is a registered trademark of General Electric Company. "Consult factory for dimensions Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. www.amesfirewater.com L A Pressure - Temperature TeriiperatureRange: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 175psi (12.06 bar) Capacity Flow curves as tested by Underwriters Laboratory per UL 1469, 1996. * Rated flow **UL Tested u_u u_. Md7. m! u• u_ a• ._. '*UL 3" (80mm) * ** kPa psi aui 0 25 50 103 50 200 250 300 350 400 450 500 550 600 gpm 95 190 300 570 700 950 1140 1300 1520 1710 1900 20902260 1pm 05 fps 4.6 mps 4JDII11Th_ Standards AWWA C51092, UL 1469 Approvals For 12 approvals consult factory. FM (a Approved C®US 1048 (sizes 2V2' -10", (OSY Only) OSY Only) kPa psi 6" (150 nn) 103 15 83 12 62 9 __L4HH 21 3 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 gpm 380 760 1140 1520 1900 2260 2660 3040 3420 3800 4160 4560 4940 5320 0708 1pm so 10 15 fps 1.5 3 4.6 lips kPa psi 8" (200mm) ** 83 11 2 62 9 41 6 Th 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 gpm 950 1900 2850 3800 .6750 5700 . 6050 7600 8550 9500 1pm 5 10 15 fps 1.5 3 4.6 raps kPa psi 10" (250mm) * ** 103 15 03 12 62 2 41 41 6 21 3 0 250 509 750 1000 1250 1500 1750 2000 2250 2500 3000 3500 gpm 950 1900 2050 3600 4750 5700 0650 7600 8550 9500 11400 13300 1pm 5 10 fps .9 3 mps kPa psi 12" (300mm) 110 16 97 14 83 17 60 10 55 8 41 0 24 4 14 2 0 500 1 030 500 2000 2500 3000 3500 4000 4500 gpm 1900 3800 5700 7600 9500 11400 13300 10200 17100 1pm 5 10 fps 1.3 3 mps SIZE (ON)_________________DIMENSIONS rlt0i41i1 lI4I51I1,i. TE in. mm A in. mm C (OSY) in. mm in. 0 mm 5 in. mm L in. mm P in, mm wlGateo lb. kg. w/o Gatos lb. kg. 21/2 65 37 965 16/8 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/2 114 10 250 22 559 141/2 368 240 109 73 33 6 150 481/2 1232 30Vo 765 5°/2 140 15 381 271/2 699 151/2 394 390 177 120 54 8 200 52/2 1334 373/4 959 1 6/4 171 15 381 291/2 749 181/2 464 572 259 180 82 10 250 551/2 1410 453/4 1162 1 8 200 15 381 291/2 749 191/2 495 774 351 190 86 12 300 571/2 1461 53Vs 1349 1 91/7 241 15 381 29V2 749 21 533 1044 474 1 220 100 AL A M E S FIRE& WATSR WORKS IMPORTANT: Inquire with governing authorities for local installation requirements. rn.r. nan a E1!JUU1 I A Division of Watts Regulator Company www.amesfirewater.com I CERTIFIED 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-3000SS 0513 ©Ames Co. 2005 MILLENNIUM FIRE PROTECTION CORP. x File Edit Print File 1iRl CITY WELLNESS CENTER.I HYDRANT GAGE_[ DIAM COEFF PIlOT FLOW Location 1 Town harden and El Camino Real 1 1 250 082: 900: 1450 Tested By rEisbad F D and Millennium Fire Remarks flid Newland and John Forsyth Date [iTh8 - Time 10 12am I Test Hydr 1 Elevation Static 92 flesid 85 . Flow 1450 6aae 25 Test Date 90 80 70 go Fi 50 40 30 20 10 0 20 0 Pi @ 5036 GPIR 16002400 3200 4000 4800 5600 6400 7200 ipu'" 8800 FLOW TEST DATA ADDRESS: 6250 El Camino Real, Carlsbad, CA DATE: February 2 I 2008 TIME: 10:12 am STATIC: 92 psi RESIDUAL: 85 psi OUTLET SIZE: 2.5" PITO: 90 psi OBSERVED FLOW: 1450 gpm CALCULATED FLOW A 20 psi: 5112 gpm 101 Copperwood Way Suite F Oceanside, CA 92058 Phone (760) 722-2722 Fax (760) 722-2730 License# C16-869040 Dyna-Flow® High Strength Steel Pipe The original high-strength IightwalI sprinkler pipe with hydraulics superior to Schedule-10. Dyna-Flow pipe is the "original" high- strength lightwall sprinkler pipe. Dyna- Flow has outstanding hydraulic capabilities and is recognized as the most popular alternative to Schedule-10 pipe. Lightweight, easy to cut and easy to handle for installation. Dyna-Flow is a valuable addition to any fire protection system. With an inside diameter of up to 11% larger than Schedule-40 and up to 7% larger than Schedule-10, Dyna-Flow pipe hydraulics are exceptional. Larger I.D.s enable Dyna-Flow, and related components, to be down-sized within the system, thus increasing the potential for job cost savings. For complete Hazen- Williams charts, refer to "Dyna-Flow Hydraulic Data Tables." NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ Wt/Lilt (21') Wt/Lift (24') Wt/lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1" 1.191 0.830 1.31 91 1,586 1,812 1,888 25 30.3 1.2 1.95 91 719 822 856 11/4" 1.536 1.059 1.87 61 1,356 1,550 1,615 32 39.0 1.6 2.78 61 615 703 733 11/2 1.728 1.667 2.71 61 2,135 2,440 2,542 40 43.9 2.5 4.03 61 968 1107 1153 2 2,203 2.104 3.79 37 1,634 1,868 1,946 50 56.0 3.1 5.64 37 741 847 883 21/2" 2.703 2.564 5.10 30 1,615 1,846 1,923 65 68.7 3.8 7.59 30 733 837 872 3 3.314 3.387 7.18 19 1,351 1,544 1,608 80 84.2 5.0 10.69 19 613 700 729 4' 4.310 4.473 10.86 19 1,784 2,039 2,124 90 109.5 6.7 16.16 19 809 925 963 Dyna-Flow products are coated with an environmentally approved and specially formulated modified-acrylic or water-based coating. This durable coating is paintable. The black coating acts as an excellent primer and is resistant to weathering and U.V. degradation from outdoor storage. Metallurgical properties provide excellent fabrication characteristics for end prep finishes, welding and roll grooving. There is no special process or equipment needed for fabrication and installation. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. Dyna-Flow/Super Flo pipe is manufac- tured to meet ASTM A-795 Type E, Grade A and is in compliance with NFPA-13 and NFPA-14. All sizes of Dyna Flow/Super Flo are UL Listed, FM Approved and ULC Listed. @ <~> 9 Listed Approved Listed Dyna-Flow/Super Ho is UL/ULC Listed for use with roll grooved, plain-end couplings, and welded joints for wet, dry, preaction and deluge systems. It is FM Approved for roll grooved, plain-end, and welded joints for wet systems. Refer to appropriate documentation for up-to-date listing and approval information. Dyna- Flow/Super Ho is now available "hot- dip" galvanized and has been specifically approved by FM for dry systems uses. Lightweight and easy to install, resulting in more efficient use of your freight and labor dollars. Provides stability needed to comply with standard hanger spacing (15 ft O.C.) per NFPA. Available in Standard lengths for your convenience, or can be ordered in custom lengths upon approval. Fast cutting and welding, as well as ea y roll grooving and end preparation. Available in Factory roll grooved form for quicker shop turnaround. Clean, durable mill coating provides longer "shelf life" and acts as an excellent primer for custom paint applications. tLICI3 a vital part of your world Ia 16100 S. Lathrop • Harvey, IL 60426 Customer Service: Pv- ciIiie 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S2 -3 DynamThread 0 Full Line Sch-40 Replacement Dyna-Thread9 offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. @ <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyn a-Thread is approved for standard hanger spacing (15 ft. can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A- 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/1)yna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). NPS Nominal I.D. WI. Wt. (H20 Filled) Pcs/ WI/Lift (21') Wt/Lift (24') Wt/Lift (25') In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft Kg/rn Lilt Lbs; Kg Lbs; Kg Lbs; Kg ill 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11/i 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 tqco c:;: cfIiecJ 16100 S. Lathrop . Harvey, IL 60426 Customer Service: 11350 Norcom Rd. . Philadelphia, PA 19154 (800) 8825543 a vital part of your world TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 tqGG Fire, & Building lProduc Is Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Grooved Fittings General Description - See Fire Protection LPcB Submittal Sheet for Pressure Rating and Listing/Approval U0 L Information The grooved fittings provide an economical and efficient method of changing direction, adding an outlet, reducing, or capping grooved piping systems. Grooved fittings are available in durable ductile iron or fabricated steel as indicated. Note: Figure 510S and 519S fittings are special short radius fittings with smaller center to end dimensions than standard grooved fittings. Depending on the size and coupling used, there may be interferences at the bolt pads that require repositioning of the coupling orientation. The use of flange adapters is not recommended with Figures 510S and 519S fittings. Contact Tyco Fire Products for details. WARNING The Fittings described herein must be installed and maintainedin compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinklermanufacturershouldbe contacted with any questions. Technical Data Approvals: UL, FM, ULC, VdS, and LPCB; Note: See Fire Protection Submittal Sheet for exact Listing / Approval information. Material: Cast: Figures: 201 210, 219,250,260, 501, 510, 519, 51 ODE, 501S, 510S and 519S - Ductile iron conforming to ASTM A-536, Grade 65-45-12 Fabricated Steel: Figures 391, 392, 393, 312, 313, 321, 327, 341 and 350- Carbon Steel. (Sizes 11/4" - 6' are Schedule 40); (Sizes 8'- 12" are Schedule 30), conforming to ASTM A-53 Grade B Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, wall thickness, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the oginaI Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Productsorfor prod ucts and components which have been subject tomisuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/orthe standards of any otherAuthorities Having Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, anyotherobligation in connection with the sale of products or parts of products. Tyco Fire ProductsshallnotberesponsibleforspnkIersyStem design errors orinaccu rate orincomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCO Fl RE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU MY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 6 September 2004 TFPI 810 Figure 210 EtsEl Figure 260 260 Figure 219 Friction Resistance* (Expressed as Equivalent Straight Pipe) Elbow Two Size 90° 45° Branch Run Feet Feet Feet Feet Inches mm Meters Meters Meters Meters 11/4 1.9 1.0 4.8 1.9 42.4 0.6 0.3 1.5 0.6 11/2 2.3 1.2 5.8 2.3 48.3 0.7 0.4 1.8 0.7 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 2/2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 4.1 2.1 10.3 4.1 76.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1,5 6.5 3.3 16.3 6.5 108.0 2.0 1.0 j 5.0 2.0 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 8.0 4.0 20.0 8.0 133.0, 2.4 1.2 6.1 2.4 8.0 4.1 20.0 8.0 139.7a,n 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 1 2.5 1.3 6.3 2.5 9.5 4.8 23.8 9.5 159.0-1 2.9 1.4 7.2 2.9 9.5 4.8 23.8 9.5 165.1mm 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 13.1 6.6 32.8 13.1 216.3=,4.0 2.0 10.0 4.0 8 13.1 6.6 32.8 13.1 219.1 4.0 2.0 10.0 4.0 10 16.5 8.3 41.3 16.5 273.0 5.0 2.5 12.6 5.0 12 19.9 9.9 49.7 19.9 323.4 6.1 3.0 15.1 6.1 Figure 201 Figure 210 Figure 219 Figure 260 45° Elbow 90° Elbow Tee En Cap C to E Appx. Wt. Cto Appx. Wt. C to E Appx. Wt. E to E Appx. Wt. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. mm Kg. 1.75 0.9 2.75 1.0 2.75 1.4 0.88 0.4 1 1/4° 44.5 0.4 69.9 0.5 69.9 0.6 22.4 0.2 1.75 1.1 2.75 1.2 2,75 1.8 0.88 0.6 44.5 0.5 69.9 0.5 69.9 0.8 22.4 0.3 2.00 1.8 • 2.0 2.7 0.9 2° 50.8 0.8 82.6 0.9 82.6 1.2 22.4 0.4 2.25 2.2 3.0 5.8 ö 0.9 21 /2" 57.2 1.0 95.3 1.4 95.3 2.6 22.4 0.4 2.25 2.2 3.75 3.0 3.75 5.8 0.94 1.1 76.1 mm 57.2 1.0 95.3 1.4 95.3 2.6 23.9 0.5 2.50 3.5 4.25 4.5 4.25 7.0 0.88 1.1 63.5 1.6 108.0 2.0 108.0 3.2 22.4 0.5 2.88 5.5 'T? 8.5 4.75 11.5 - 108.0mm 70 2.5 120.7 3.9 120.7 5.2 3.00 5.2 • 8.5 5.00 11.8 1.00 2.6 76.2 2.4 127.0 3.9 127.0 5.4 25.4 1.2 3.25 7.7 5.25 11.3 5.25 10.6 - 133.0mm 82.6 3.5 133.4 5.1 133.4 4.8 - 7.7 11.3 15.3 4.7 139.7mm 82.6 3.5 139.7 5.1 139.7 6.9 23.4 2.1 3.25 8.5 5.50 13.5 5.50 17.0 1.00 5.0 5.1 82.6 3.9 139.7 6.1 139.7 7.7 25.4 2.3 3.50 12.0 6.00 14.6 6.00 13.9 159.0mm 88.9 5.4 152.4 6.6 152,4 6.3 - 3.50 12.0 6.50 18.5 26.0 1.00 7.5 165.1 mm 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 3.50 12.0 6.50 18.5 6.50 26.0 1.00 7.5 6° 88.9 5.4 165.1 8.4 165.1 11.8 25.4 3.4 4.25 23.0 7 36.5 7.75 45.0 - 216.3mm 108.0 10.4 196.9 16.6 196.9 20.4 - - 23.0 36.5 T7 45.0 T1 12.8 81. 108.0 10.4 196.9 16.6 196.9 20.4 30.2 5.8 4.75 31.0 9.00 60.0 9.00 72.1 T 20.0 10 120.7 14,1 228.6 272 228.6 32.7 31.8 9.1 5.25 40.0 Thöö 67.0 10.00 92.5 1.25 36.0 12° 1334 18.1 254.0 30.4 254.0 42.0 31.8 16.3 -Available with tapped plugs, Contact Tyco Fire & Building Products. to Figure 201 Page 2 of 6 TFP 1810 jLI I411111111 '1 4.i'W Ei:jT.IS For reducing tees and branches, use the value that is corresponding to the branch size. Example: for 8 x 8 5 2' tee, the branch value 2' is 8.0 feet. Friction resistance for all elbows and tees except Figures 510S and 519S. Figure 501S Friction Resistance 501S, 510S & 5195 (Expressed as Equivalent Straight Pipe) Elbow The 900 451 Branch Run Size Feet Feet Feet Feet Inches MM Meters Meters Meters Meters 2 3.2 1.6 8.0 3.2 60.3 1.0 0.5 2.5 1.0 21/2 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 76.1 010 4.1 2.1 10.3 4.1 1.2 0.6 3.1 1.2 3 4.9 2.4 12.2 4.9 88.9 1.5 0.7 3.7 1.5 4 6.5 3.3 16.3 6.5 114.3 2.0 1.0 5.0 2.0 13970101 8.0 4.1 20.0 8.0 2.4 1.3 6.1 2.4 5 8.2 4.1 20.5 8.2 141.3 2.5 1.3 6.3 2.5 165 1fllfll 9.5 4.8 23.8 9.5 2.9 1.4 7.2 2.9 6 9.9 5.0 24.8 9.9 168.3 3.0 1.5 7.6 3.0 8 13.1 6.6 32.8 13.1 I 219.1 1 40 2.0 1 10.0 4.0 Page 3of6 TFP1810 Figures 501, 510, 519 and 51 ODE '-C to E Figure 510 i-Cia cci', Figure 519 + I C to 2 4fOE Figure 51 ODE Figure 501 Figure 501 Figure 510 Figure 519 Figure 51 ODE 45° Elbow 90° Elbow Tee 900 Drain Elbow C to E Appx. WI. C to E Appx. WI. C to E Appx. WI. C to E A B Appx. Wt. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Inches Inches Inches Lbs. Size mm Kg. mm Kg. mm Kg. mm mm mm Kg. 1.75 0.9 2.75 1.0 2.75 1.4 1/4 44.5 0.4 69.9 0.5 69.9 0.6 - - - 1.75 1.1 2.75 1.2 2.75 1.8 1/2 44.5 0.5 69.9 0.5 69.9 0.8 - - - 2.00 1.8 3.25 2.0 3.25 2.7 2 50.8 0.8 82.6 0.9 82.6 1.2 - 2.25 2.2 3.75 3.0 3.75 5.8 3.75 2.00 2.75 2.7 2 /2 57.2 1.0 95.3 1.4 95.3 2.6 95.3 50.8 69.9 1.2 2.50 3.5 4.25 4.5 4.25 7.0 4.25 2.34 2.75 3.7 63.5 1.6 108.0 2.0 108.0 3.2 108.0 59.4 69.9 1.7 3.00 5.2 5.00 8.5 5.00 11.8 5.00 2.85 2.75 7.0 76.2 2.4 127.0 3.9 127.0 54 127.0 72.4 69.9 3.2 3.25 8.5 5.50 13.5 5.50 17.0 5.50 3.38 2.75 13.0 51, 82.6 3.9 139.7 6.1 139.7 7.7 139.7 85.9 69.9 5.9 3.50 12.0 6.50 18.5 6.50 26.0 6.50 3.92 2.75 13.4 6 88.9 5.4 165.1 8.4 165.1 11.8 165.1 99.6 69.9 6.1 4.25 23.0 7.75 36.5 7.75 45.0 7.75 4.95 2.75 26.3 8° 108.0 10.4 196.9 16.6 196.9 20.4 196.9 125,7 69.9 11.9 Figures 501S, 51 OS and 5195 I-CE Figure 51 OS' Figure 519S* Figure 501S 1 Figure 510S Figure 5195 45° Elbow 90° Elbow Tee Appx WI. Appx. Wt. CtoE Appx. WI. Nominal Inches Lbs. Inches Lbs. Inches Lbs. Size mm Kg. mm Kg. mm Kg. 2.00 1.8 1.5 2.1 2° 50.8 0.8 69.9 0.7 69.9 1.0 2.25 2.2 3.00 2.2 3.00 3.0 21/2 57.2 1.0 76.2 1.0 76.2 1.4 2.25 2.2 3.00 2.3 355 3.1 76.1001 57.2 1.0 76.2 1.0 76.2 1.4 2,50 3.5 3.38 3.0 3.38 4.1 311 63.5 1.6 85.9 1.3 85.9 1.9 3.00 5.2 4.00 5.6 4.00 7.7 40 76.2 2.4 101.6 2.6 101.6 3.5 377 7.7 4.88 8.6 4,88 12.0 139.7001 82.6 3.5 124.0 3.9 1 124.0 5.4 3.25 8.5 8.8 12.0 511 82.6 3.9 124.0 3.9 124.0 5.4 TU 12.0 11.00 5 15.0 165.10101 88.9 5.4 139.7 5.0 139.7 6.8 12.0 T5 11.2 15.2 6° 88.9 5.4 139.7 5.1 139.7 6.9 4.25 23.0 23.4 31.2 8° 108 10.4 174.8 10.6 174.8 14.2 *Note: Figure 510S and 519S fittings are special seen raslon fittings WitS smarier center to one urmenurono than standard groaned fittings. Depending on the size and coupling used, there may be interferences at the butt pads which requires repositioning of the coupling orientation. The use of flange adaptors is not recommended with Figures hiltS and 519S fittings. Contact Tyco Fire Products for details. Pi )e Nominal Dimensions Net 0. D. Takeout Center to End Size Outlet D I. A B C Inches NPT* Inches Inches Inches Inches Lbs. Inches m m mm mm m m Kg. 1.25 1.75 1.89 0.77 1/ 2 31.8 44.5 48.0 0.3 11/2 2/4 1.900 1.25 1.75 1.89 0.77 48.3 31.8 44.5 48.0 0.3 1.37 2.00 2.02 0.88 1 34.8 50.8 51.3 0.4 1.25 1.75 1.89 0.92 1/2 31.8 44.5 48.0 0.4 3/4 1.25 1.75 1.89 0.92 2 2.375 60.3 31.8 44.5 48.0 0.4 1.37 2.00 2.02 1.06 1 34.8 50.8 51.3 0.5 1.47 1.97 1.89 1.28 1/2 373 50.0 48.0 0.6 2.875 1.47 1.97 1.89 1.28 21/2 .3/4 73.0 37.3 50.0 48.0 0.6 1.37 2.00 2.02 1.50 1 34.8 50.8 51.3 0.7 f L Page 4 of 6 TFP181O Figures 250 and 350 Concentric Reducer - Groove x Groove Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Nominal E to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. Inches mm Kg. *2 x 1½ 2.50 63.5 1.0 0.5 *1397 x 3.50 88.9 4.2 1.9 *6 X 4.00 101.6 5.8 2.6 2.50 1.3 3.50 4.4 5.00 12.2 *2 X 11/2 63.5 0.6 *1397 X 88.9 2.0 8 X 2 1270 5.5 *21/. x 2 2.50 63.5 1.2 0.5 5 x 1/ 3.50 86.9 4.6 2.1 8 x 21/2 5.00 127.0 12.1 5.5 *76.1- X 1½ 2.50 63.5 1.5 07 5 x2 3.50 88.9 4.6 2.1 8 x 3 5.00 127.0 12.0 5.5 2.50 1.6 3.50 4.5 5.00 11.9 *76.1mm x 2 63.5 0.8 5 X 2'/ 88.9 2.0 8 x 4 127.0 5.4 2.50 1.3 3.50 4.4 5.00 11.3 3x 1½ 63.5 0.6 5x3 88.9 2.0 8x5 127.0 5.1 2.50 1.3 3.50 4.5 5.00 10.8 3 x 1½ 63.5 0.6 *5 x ' 88.9 2.0 8 x 6 127.0 4.9 2.50 1.3 4.00 5.5 6.00 21.9 3 x 2 63.5 0.6 165.1 x 101.6 2.5 lOx 152.4 10.0 *3 X 2½ 3.00 76.2 1.5 0.7 *165.1mm X 4.00 101.6 6.0 2.7 lOx 5 6.00 152.4 21.6 9.8 3.00 2.0 4.00 5.6 6.00 21.1 *3 x 76.1mm 76.2 0.9 *1651x1397 101.6 2.5 10 x 6 152.4 9.6 4 xl 1/4 3.00 76.2 2.2 1.0 *6 x 2 4.00 101.6 6.0 2.7 10 x 8 6.00 152.4 19.5 8.9 3.00 2.3 4.00 6.0 7.00 28.0 4 x 1½ 76.2 1.0 6 x 2½ 101.6 2.7 12 x 177.8 12.7 3.00 2.3 4.00 6.0 7.00 30.0 *4 x 2 76.2 1.0 '6x76.1- 101.6 2.7 12 x 6 177.8 13.6 3.00 2.3 4.00 6.0 7.00 28.0 *4 x 2½ 76.2 1.0 6 x 3 101.6 2.7 12 x 8 177,8 12.7 3.00 3.2 4.00 5.9 7.00 33.0 *4 x 76.1 mm 76.2 1.5 *6 X 101.6 2.7 12 X 10 177.8 1 15.0 3.00 2.6 4.00 6.3 x 76.2 1.2 *6 x 101.6 2.9 Note: Sizes marked with an asterisk () are only available in Figure 250 Cast. Sizes without an asterisk are only available in Figure 350 Fabricated. M Figure 250 Cast -E to E-1 Figure 350 Fabricated Sizes 3" to 6" to -D- Figure 350 Fabricated Sizes 8" to 12" Patented ISO-7 threaded outlets are available upon request. Figures 391, Figure 312 Figure 313 392 and 393 Adapter Nipples 22/20 Elbow 111/40 Elbow E to E Appx. Wt. C to E Appx. Wt. C to E Appx. Wt. Nominal Inches Lbs. Inches Lbs, Inches Lbs. Size mm Kg. mm Kg. mm Kg. 4.00 0.8 1.75 0.4 1.38 0.4 11/4" 101.6 0.4 44.5 0.2 35.1 0.2 4.00 0.9 1.75 0.5 1.38 0.5 1h/2' 101.6 0.4 44.5 0.2 35.1 0.2 4.00 1.2 1.88 0.6 1.38 0.6 2° 101.6 0.5 47.8 0.3 35.1 0.3 4.00 1.9 2.00 0.7 1.50 1.1 21/2 101.6 0.9 50.8 0.3 38.1 0.5 4.00 2.5 2.25 1,4 1.50 1.2 101.6 1.1 57.2 0.6 38.1 0.5 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.8 1.1 1.0 6.00 7.4 44.5 51 2.88 4.1 aoo 3.3 152.4 3.4 73.2 1.9 50.8 1.5 6.00 9.5 3.13 5.6 aoo 4.6 6" 152.4 4.3 79.5 2.5 50.8 2.1 6.00 14.2 3.88 11.1 2.00 8.7 8' 152.4 6.4 98.6 5.0 50.8 3.9 8.00 27.0 4.38 14.0 2.13 9.1 10" 203.2 12.2 11.3 6.4 54.1 4.1 8.00 33.0 4.88 22.0 225 16.7 12" 203.2 15.0 124.0 10.0 572 7.6 F'- C to E -ø Figure 391 391 C to C Figure 392 -Efill- - Figure 393 Figure 312 C to C to E Figure 313 C to &E Figure 327 Figure 341 Cross 150 lbs. Flange Adapter C to E Appx. Wt. E to E Appx. Wt. Nominal riches Lbs. Inches Lbs. Size mm kg. mm kg. 2.75 2.0 4.00 2.8 11/4 69.6 0.9 101.6 1.3 2.75 2.2 4.00 3.2 11/2" 69.9 2.0 101.6 1.5 3.25 2.7 4.0 5.2 2" 82.6 1.2 101.6 2.4 3.75 5.0 4.00 8.0 21/2 953 2.3 101.6 3.6 4.25 7.1 4.00 10.2 108.0 3.2 101.6 4.6 5.00 11.9 6.00 17.2 127.0 5.4 152.4 7.8 5.50 17.1 6.00 21.4 5.1 139.7 7.8 152.4 9.7 6.50 27.5 6.00 26.0 6" 165.1 12.5 152.4 11.8 7.75 47.0 6.00 38.4 8" 196.9 21.3 152.4 174 9.00 68.0 8.00 65.0 10 228.6 30.8 203.2 29.5 10.00 107.0 8.00 91.0 12" 254.0 48.5 203.2 41.3 Figure 327 I. EtoE Figure 341 Page 5of6 TFP1810 Figures 391, 3925 3935 312 and 313 Figures 327 and 341 L___ CtoE - .] Figure 321 Page 6 of 6 TFP181O Figure 321 Reducing Tee Nominal C to E Appx. Wt. Nominal C to E Appx. Wt. Size Inches Lbs. Size Inches Lbs. Inches mm Kg. Inches mm Kg. 11/2 X 1½ x 1 3.25 82.6 2.0 0.9 6 x 6 x 4 6.50 165.1 26.6 12.1 2 x 2 11 3.25 82.6 2.7 1.2 6x6x5 6.50 165.1 27.0 12.2 21/k x 21/2 3.75 95.3 4.2 1.9 8x8x2 7.75 196.9 36.2 16.4 21/2 x 21/2 x 1112 95.3 3.75 4.2 1.9 8x8x3 7.75 196.9 36.5 16,6 21/2 x21/.,x2 3.75 95.3 4.3 2.0 8x8x4 7.75 196.9 36.6 16.6 3x3x1½ 4.25 108.0 1 5.3 2.4 8x8x5 775 196.9 36.8 16.7 3x3x2 4.25 108.0 5.5 2.5 8x8x6 ____________ 7.75 196.9 37.0 16.8 3x 3 x 21/'2 4.25 108.0 5.8 2.6 10x 10x2 9.00 228.6 57.1 25.9 4 x 4 x 11A 5.00 127.0 9.8 4.4 lOx 10x3 9.00 228.6 57.4 26.0 4x4x1112. 5.00 127.0 9.9 4.5 10x 10x4 9.00 228.6 57.6 26.1 4x4x2 5.00 127.0 10.1 4.6 10 10x5 9.00 228.6 57.8 26.2 4x4x2½ 5.00 127.0 10.3 4.7 lOx 10x6 9.00 228.6 58.0 26.3 4x4x3 5.00 127.0 10.5 4.8 10x 10x8 9.00 228.6 58.4 26.5 5 x 5 x 2 5.50 14.5 12 x 12 x 3 10.00 80.2 139.7 6.6 254.0 36.4 5x5x2½ 5.50 14.8 12x 12x4 10.00 80.5 139.7 6.7 254.0 36.5 5x5x3 5.50 15.2 12x12x5 10.00 80.7 139.7 6.9 254.0 36.6 X 5 x 4 5.50 15.8 12 x 12 x 6 10.00 80.9 139.7 7.2 254.0 36.7 6x6x2 6.50 26.5 12x12x8 10.00 91.4 165.1 11.9 254.0 41.5 6 x 6 x 21/2 6.50 26.5 12 x 12 x 10 10.00 91.8 165.1 12.0 254.0 41.6 6x6x3 6.50 26.5 165.1 12.0 General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions , 9001, (IH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 General Description S See Fire Protection Submittal Sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI 1316.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/2" - 21/2 Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. rA Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. 171 Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 -2- Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 V/8 /16 86206 0.24 240 3/4 1I16 3/4 86205 0.40 120 1 11/2 13/16 86200 0.64 70 11/4 1/4 1 11/16 86201 0.95 40 1V2 1 '5/16 13/16 86202 1.24 30 2 21/4 11/2 86203 174 20 21/2 2'1/16 1/16 86204 3.28 10 Figure 815 Reducing Tee L- I- D-1 1-7 TIL Figure 812 90° Reducing Elbow a, - I Size Inches A Inches B Inches C Inches 0 Inches Part Number Weight Lbs. Box Oty. /4xV2 1/16 1I16 5/ 5/ 86342 0.33 160 1 x Y2 11/4 13/8 /18 13/16 86210 0.44 110 1 x 3/4 13/s 1/16 11/16 7/ 86211 0.53 90 1V4 X 1/3 1/16 11/2 5/ 15/16 86212 0.64 75 11/4 X3/4 1/16 1/s 3/4 11/16 86213 0.75 60 1 '/4 x 1 15l16 111/16 7J 1 86214 0.77 55 11/2 x 3/4 1 /2 1/4 3/4 1/16 86221 0.95 45 11/2 X1 1 15/s 113/16 7/ 1 /s 86215 0.99 40 11/2X 11/4 1 3/16 17/8 1 V 1/16 86216 1.14 35 2 x 3/4 1/8 1 '5/16 /8 1/e 86217 1.39 30 2x 1 1/4 21/16 2 15/is 86218 1.58 25 2X 1/2 2 2/16 11/4 1/16 86220 1.67 20 2'/2 x 2 2/s 25/s 1/4 1/s 86262 3.01 15 Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 7/ 3/ 86780 0.22 250 3/4 1 7/16 86781 0.33 150 1 1 11/8 13/is 86280 0.48 90 1/4 15/16 5/ 86281 0.73 50 11/2 1/16 11/16 86282 0.93 35 2 i"/is 15/16 86283 1.55 18 2V2 1 '/16 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 11/6 s/16 86340 0.33 150 3/4 1/16 3/4 86341 0.50 90 1 11/2 13/16 86230 0.85 60 11/4 1/4 1/16 86231 1.30 35 1/2 1 /16 13/16 86232 1.63 24 2 21/4 1/2 86233 2.63 12 21/2 211/16 19/16 86234 4.55 8 Se Inches A Inches B Inches C Inches D Inches E Inches I F Inches I Part Number Wt. Lbs. Box W. 3/4X3/4X 1/2 13/16 13/16 11/4 5/ '/8 1 11/16 186235 0.46 95 3/4X3/4 X1 17/16 i'/is 1/s 7/ 7/ Wis 86755 0.68 65 1x1/2x1 11/2 1/s 1/2 13/16 i3/15 13/is 86236 0.70 55 1 X3/4X/2 11/4 1/16 1/8 6/16 5/8 1 13/16 86756 0.631 80 1 X 3/4 X 1/4 1/8 15/16 1/16 11/16 3/4 7/e 8 757 0.681 65 1 x3/X 1 11/2 i'/is 11/2 13/1s 7/5 13/16 86237 0.771 55 lxi X1/2 1/4 11/4 1/6 s/is /l6 13/16 86238 0.66 65 lxi X3/4 is/s 1/8 1/10 11/i6 11/16 7/ 86239 0.73 60 lxi xlV4 111/16 11/16 1/1e 1 1 7/ 86240 0.97 45 lxi x 11/2 113/16 Vs/is 15/s 11/8 11/8 7/ 186241 1.14 35 11/4x1 X1/2 115/16 11/4 19/16 5/ 9/16 1 186242 0.81 50 1/4X1 x3/4 17/ 16 13/s 1/8 3/4 11/16 P/is 186243 0.90 50 11/4x1 X 15/16 1/2 111/16 7/ 13/16 1 186244 1.03 45 1/4X1 x1V4 l/4 111/16 i/4 11/16 1 V/is 186245 1.10 40 11/4 x1x1'/2 1/8 1 '/16 113/16 1/16 V/s 1 V1 186246 1.43 30 11/4 x11/4 x1/2 1/6 1/8 1/16 "/is 11/16 1 1 186247 0.87 45 11/4x11/4X3/4 1/I6 1/16 15/8 3/4 3/4 1/16 186248 0.96 45 V/4x11/4x1 19/16 19/16 111/16 7/ 7/ 1 86249 1.10 40 11/4xli/4x11/2 17/8 17/8 113/16 113/16 13/16 11/16 86250 1.50 30 11/4x11/4x2 21/s 21/8 2 17 /16 17/ 16 P/s 86251 2.00 24 11/2 X1 XV2 17/ 16 15/16 111/16 11/16 5/ V/s 86252 0.97 40 1V2x1 x3/4 11/2 13/8 1/4 3/4 11/I6 1 13/16 186253 1.141 40 11/2x1 X 15/8 11/2 113/16 7/ 13/16 1 V/s 186254 1.14 30 11/2x1 x11/2 115/16 113/16 115/16 13/16 V/s 1 is/is 186255 1.52 30 11/2X11/4X1/2 17/16 1/16 111/16 1 11/16 5/ 1 1'/s 186257 1.03 40 11/2x1V4x3/4 1/2 i/is 1/4 3/4 3/4 13/16 86258 1.10 40 11/2x11/4 x1 15/8 1/16 11/16 7/ 7/ V/s 86259 1.31 30 11/2x11/4 x2 2/16 21/e 2 1/16 17/1e 11/4 86260 1.94 20 11/2x11/2 x1/2 1/i6 1/16 1hl/16 11/16 11/16 V/s 86261 1.14 35 1V2x1 /2x3/4 11/2 11/2 1/4 3/4 3/4 1/is 86262 1.23 35 11/2x11/2x1 15/s 15/s 113/is 7/ 7/ 11/8 186263 1.38 30 11/2x11/2x11/4 113/16 113/16 1/8 V/is V/is 13/16 186264 1.50 30 11/2x11/2x2 23/16 23/16 2 17/16 1/16 11/4 86265 2.00 20 2x1 x2 21/4 2 21/4 11/2 15/16 11/2 86266 2.18 15 2X11/4X2 21/4 21/8 21/4 1/2 17/16 11/2 86267 2.31 15 2x11/2x1/2 11/2 17/16 1/8 3/4 11/16 15/16 186268 1.50 30 2x1'/2x3/4 15/s 11/2 115/is 7/ 3/4 13/8 186269 1.61 25 2XP/2X1 1/4 15/s 2 1 7/ lb/is 186270 1.65 20 2x11/2x11/2 2V16 Vs/is 23/16 1/16 13/16 17/16 86272 2.03 20 2x1'/2x2 21/4 23/16 21/4 1/2 17/ 16 1/2 86273 2.37 15 2x2x1/2 11/2 11/2 17/8 3/4 3/4 15/16 86222 1.50 30 2X2x3/4 1/s 1/s 15/is 7/ 7/ 13/8 86223 1.67 20 2x2x1 1/4 13/s 2 1 1 15/16 86224 1.91 20 2X2X11/4 17/s 1/8 21/8 11/6 V/s 17/16 86225 2.05 20 2x2x11/2 2 2 23/16 11/4 11/4 11/2 86226 2.11 15 2X2X21/2 25/8 25/s 2/8 1/4 1/e 17/16 86227 3.67 10 21/2 X2x3/4 1 1/4 1 1/s 25/is 5/ 7/ 1/4 86274 2.22 15 Figure 811 90° Elbow Figure 813 45° Elbow Figure 814 Tee Size Inches A Inches B Inches Part Number Weight I Lbs. Box Oty. 3/4 x 1/2 1/4 "/16 86772 0.38 240 1 X 1/2 1/,e 1/2 86228 0.38 200 1 x 3/4 1/4 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/2 x 1V2 V/2 1 72751 0.20 300 1/2 x 2 2 72980 0.27 250 3/4 x 11/2 11/2 72981 0.22 250 3/4 x 2 2 72982 1 0.31 12001 Figure 816 Reducing Coupling Figure 719 Cast Iron Plug Figure 817 Cross Figure 827 Hex Bushing Size Inches A Inches B Inches C Inches D Inches Part Number Weight Lbs. Box Oty. 1 1'/x 11/2 '/16 13/16 86284 0.97 45 1V4 1/4 1/4 11/16 11/16 86285 1.59 25 11/2 115/16 115/16 1 3A6 13/16 86286 1.89 20 2 21/4 21/4 11/2 11/2 86287 2.93 10 11/4 X 1V4X 1 X 1 1/16 1 /16 1 7/ 86289 1.25 30 11/2 X 11/2 x 1 x 1 113/16 1/s 11/16 115/16 86322 1.48 24 2 x 2 x 1 x 2 1/4 11/4 1/16 86291 2.64 10 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1 X V2 1'/16 72726 0.22 280 1 x 3/4 11/16 72762 0.18 280 11/4 x1 1/16 72763 0.31 150 1V2 X 1 '/4 72757 0.53 100 11/2X11/4 1114 72764 0.35 100 2 x 1 13/e 72759 0.75 80 2 x 11/4 1/8 72761 0.69 80 2 x 11/2 13/8 72775 0.62 80 Figure 818 E3 k Straight Coupling Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Qty. 1/2 1/8 5A6 72779 j1/ 0.18 360 3/4 1/s 9/,5 72778 13/8 0.26 200 1 1/4 3/ 72755 1ll/16 0.44 110 11/4 2 9/16 72754 2 0.54 75 1V2 2/16 3/4 72753 2V4 0.71 60 2 2Is U/8 72752 2/4 1.15 30 21/2 3 3/4 72758 33/s 2.29 18 Figure 830 _____________ Brass Seat Union Size Inches A Inches B Inches Part Number Weight Lbs. Box Qty. 1/2 1 1/8 1 13/16 86207 0.47 110 3/4 2 's/i6 86275 0.66 80 1 2/6 '/16 86276 1.08 50 11/4 21/2 11/16 86277 1.54 35 11/2 2/s 1 /16 86278 2.03 25 2 31/8 15/e 86279 3.15 18 Figure 820 Cap 1-7 IHIJ Size Inches A I Inches Part Number Weight Lbs. Box Oty. 1/2 7/ 72776 0.15 500 3/4 1 72777 0.22 300 1 1/1e 72824 0.33 180 11/4 1/,6 72756 0.54 110 11/2 1/s 72822 0.68 80 2 11/2 72823 0.96 45 2V2 1/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Qty. 1/x 15/is 86292 0.10 500 3/4 11/8 86293 0.18 300 1 11/4 86294 0.28 200 11/4 is/8 86295 0.50 110 1'/x 1/,s 86296 0.70 80 2 11/2 86297 0.90 45 -3- Street Elbows Size Inches A Inches B Inches C Inches Part Number I Weight lbs. Box Oty. 1 X 1/2 1V2 3/4 3 42003 0.70 80 1 X 1 1V2 3/4 3 42002 0.90 60 California Tees C L L Size Inches A Inches B Inches C Inches I D Inches Part Number Weight lbs. Box Q. 1 x 1/2 x 1 11/2 /8 3 3A 42000 0.95 50 1 X 1 X 1 11/2 3/4 3 3/4 42001 0.95 45 NILimited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OFANYAND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that . . I . . pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify any ' piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified . o 1 to be compatible for the specific application. tqco/F/ow Control/ Tyco Fire Printed U.S.A. 10-01 Products tLICO Fire & Sal/cling Iprodtw-.-Is Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented General Description uipcB --- See Fire Protection FM Submittal Sheet for Pressure Rating and Listing/Approval Information The Figure 772 Rigid Coupling provides rigid joint by firmly gripping along the circumference of the pipe grooves. Rigid couplings are preferred for dry pipe and freezer applications. Figure 772 Rigid Couplings are a proven dependable method of joining pipe and are an economical alternative to welding, threading or using flanges. It is capable of pressures upto 500 psig (3447 kPa) depending on pipe size and wallthickness when used in fire protection services. Rigid Couplings are recommended for diy pipe and freezer applications. WARNING The Figure 772 Rigid Coupling described herein must beinstalledand maintainedin compliance with thisdocument,aswellas with theappllcablestandards oftheNationalFireProtectionAssociation, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershouldbe contacted withanyquestions. Technical Data Figure: 772 Sizes: 1%"-12' Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing/ Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psV758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) Grade "A" EPDMA violet color code ambientto +150°F (+66°C) forfire protection systems. Not recommended for hot water systems. Tr-seal (Grade "E" EPDM), green colorcode for use in dry pipe or freezer systems. Prelubricated (Grade "A" EPDMA) (See Data Sheet TFP1 895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "E"EPDMTni-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractororproduct manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Art i1!T.i III F74t1.ii Products manufactured by Tyco Fire Products are warranted solelyto the original Buyerforten (10) years againstdetectsinmaterialandworkmanshipwtienpaid forand properly installed and maintained under normal useandservice. Thiswarrantywillexpireten (10)years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured bycompaniesnotaffiliatedbyownership withTycoFire Products orforproductsandcomponents which havebeensubjectto misuse, impropeninsta]lation, corrosion, orwhich have notbeen installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person toassumefor it, any otherobligationin connection with the sale of products or parts of products. Tyco Are Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO ARE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDERPNYOTHERLEGALThEORY,FORINCIDEI\ffAL INDIRECT, SPECIALORCONSEOUENI1ALD/WIAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHEThERTYCO FIRE PRODUCTS WAS INFORMED ABOUTThE POSSIBILITY OFSUCH DAMAGES, AND IN NO EVENT SHALL TYCO ARE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 11 of 2 July 2004 TFPI85O Page 2of 2 - TFP1850 Figure 772 Grooved Coupling Pipe Max.*t Max.t Max.t Nominal Dimensions Net End Gap Pressure End Load Bolt Wt. 0. D. A B C Size Inches Inches psi Lbs. Inches Inches Inches Lbs. MM mm kPa N mm mm mm Di a. X g.Kq 11/4 1.660 0.06 300 649 2.75 4.38 1.81 3/8" x 21/4 1.0 42.4 1.5 2,068 2,887 69.9 111.3 46.0 M10x57 0.5 11/2" 1.900 0.08 500 1,417 3.00 4.62 1.81 %"x214" 1.0 48.3 2.0 3,447 6,303 76.2 117.3 46.0 M10x57 0.5 2" 2.375 0.13 500 2,214 3.41 5.12 1.88 %" x 21/4" 1.5 60.3 3.3 3,447 9,848 86.6 130.0 47.8 M10x57 0.7 21/2" 2.875 0.13 500 3,244 3.91 5.63 1.88 %" X21/4" 2.5 73.0 3.3 3,447 14,430 99.3 143.0 47.8 M10x57 1.1 76.1 mm 3.000 0.13 300 2,120 4.19 5.72 2.00 M10x57 2.6 76.1 3.3 2,068 9,430 106.4 1453 50.8 1.2 30 3.500 0.13 500 4,808 4.63 6.25 1.88 /8" x 21/4" 2.6 88.9 3.3 3,447 21,387 1176 1588 47.8 M10x57 1.2 4.500 0.19 500 7,948 5.81 7.50 1.97 3/a" x 21/4" 3.5 114.3 4.8 3,447 35,353 1476 190.5 50.0 M10x57 1.6 139.7mm 5.500 0.19 300 7,127 7.02 9.72 2.06 M16 x 83 7.5 139.7 4.8 2,068 31,701 178.3 249 52.3 3.4 5.563 0.19 300 7,288 7.09 9.71 2.04 5/6" x 31/4" 7.5 141,3 4.8 2,068 32,417 180.1 246.6 51.8 M16x83 3.4 165.1 mm 6.500 0.19 300 9,950 8.09 10.53 2.13 M16x83 7.6 165.1 4.8 2,068 44,258 2055 267.5 54.1 3.4 6" 6.625 0.19 400 13,782 8.09 10.53 2.13 %" x 3/" 7.6 168.3 4.8 2,758 61,302 205.5 2675 54.1 M16 x 83 3.4 8" 8.625 0.19 450 26,278 10.56 13.56 2.62 3/4" x 43/4 18.0 219.1 4.8 3,103 116,885 268.2 344.4 66.5 M20x121 8.2 101, 10.750 0.13 250 22,679 12.84 16.41 2.62 1" x 61/2" 24.6 273.0 3.3 1,724 100,876 326. 1 416.8 66.5 M24 x 165 11.2 12" 1 12.750 0.13 250 31,903 15.41 18,841 2.62 1 lx 61/2' 42.0 323.9 3.3 1,724 141,905 391.4 478.5 66.5 1 M24x 165 19.1 Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. Gold color coded metric bolt sizes are available upon request. Max End Gap is for cut grooved standard weight pipe. Values for roll grooved pipe will be ½ that of cut grooved. Figure 772 Rigid Couplings have an Anti-Rotation Feature of "gripping teeth" along the coupling keys in sizes 11/4" - 4", which make the Figure 772 perfectly suited for "arm over" installations where the likelihood of rotation is greatest. This feature may eliminate the need of extra hangers to support the arm over due to increased rigidity and gripping force saving time and cost. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (lH-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. tijo &e & &.illc//rig liprodtict,5 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 705 Flexible Coupling General Description [LPcB]: UL cj See Fire Protection Submittal Sheet for M Pressure Rating and Listing/Approval Information The Figure 705 Flexible Coupling is capable of pressures up to 300 psig (2068 kPa) depending on pipe size and wall thickness when used in fire protection services. It provides a dependable method of joining pipe and is suitable for use in a variety of applications. Rigid Couplings are recommended for dry pipe and freezer applications. WARNING The Figure 705 Flexible Coupling described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any otherauthorities ha ving jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershou/dbe contacted with any questions. Technical Data Figure: 705 Sizes: 11/4" - 12" Approvals: UL, FM, ULC, VdS, and LPCB; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: 'Non-lead orange paint Fire brigade red (optional) non-lead paint 'Hot dipped galvanized conforming to ASTM A-153 Bolt/Nuts: Track Head Bolts - conforming to ASTM A-183, Zinc Plated, (Mm. Tensile = 110,000 psi/758,422 kPa) Metric - conforming to ASTM F568M Gasket: (specify when ordering) Grade "A" EPDMA violet color code ambientto +150°F (+66°C) forfire protection systems. Not recommended for hot water systems. Tr-seal (Grade "E" EPDM), green colorcode. Prelubricated (Grade 'A" EPDMA) (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "A" EPDMA, Prelubricated (Grade "A" EPDMA) or Grade "E" EPDM Tr-Seal, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in matedal and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products orfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), anWorthe standards ofany otherAuthodties Having Jurisdiction. Materials found byTyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assu meforit, any otherobligation in connectionwith the sale of products or parts of products. Tyco Fire Products shall not beresponsibleforspdnklersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENTSHALL1YCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 2 July 2004 TFPI820 Page 20f2 TFP1820 Figure 705 Grooved Coupling Pipe Max. *4 End Gap Max.t Pressure Max.t End load Nominal Dimensions Deflection t Bolt Size** Net Wt. 0. D. A B C 'Per Inches! Size Inches Inches psi Lbs. Inches Inches Inches Coupling Foot Dia.xLg. Lbs. mm mm kPa N mm mm mm mm/rn Kg. 1.660 0.13 300 649 2.56 4.19 1.81 4° 19 0.90 I8 x 2114 1.5 11/4 424 3.3 2,068 2,887 65.0 106.4 46.0 75.0 MIO x 57 0.7 1.900 0.13 300 850 2.75 4.44 1.81 3046 0.79 Ie" X2V4' T 1½" 48.3 3.3 2,068 3,781 69.9 112.8 46.0 65.8 M10x57 0.7 2.375 0.13 300 1,328 3.25 4.88 1.88 30 1 0.63 3/e°X2V4' 1.7 2" 60.3 3.3 2,068 5,907 82.6 124,0 47.8 52.5 M10x57 0.8 2.875 0.13 300 1,947 3.69 5.50 1.88 0.52 3/8 X2V4' 2.0 2½' 73.0 3.3 2,068 8,660 93.7 139.7 47.8 2° 29 43.3 - M10 x 57 0.9 76,1mm 3.000 0.13 300 2,120 4.00 5.75 1.88 2°-23' 0.50 M12x76 3.1 76.1 3.3 2,068 9,430 101.6 146.1 47.8 41.7 1.4 3.500 0.13 300 2,885 4.38 6.50 1.88 2° - ' 0.43 1/2',x 3° 3.0 88.9 3.3 2,068 12,832 111.3 165.1 47.8 35.8 M12 x 76 1.4 108.0mm 4.250 0.25 300 4,256 5.50 7.50 2.06 3022 0.70 M12 X 76 4.2 108.0 6.4 2,068 18,931 139.7 190.5 52.3 58.3 1.9 4.500 0.25 300 4,769 5.69 7.75 2.06 - °11 ' 0.67 1/2" x 3' 4.0 114.3 6.4 2,068 21,213 144.5 196.9 52.3 55.8 M12 76 1.8 133.0mm 5.250 0.25 300 6,494 6.56 9.50 2.06 2° -44' 0.56 M16 x 83 3.3 7.2 133.0 6.4 2,068 28,885 166.6 241.3 52.3 467 139.7mm 5.500 0.25 300 7,127 6.81 9.75 2.06 2° 36' 0.56 M16x83 3.3 7.2 139.7 6.4 2,068 31,701 173.0 247.7 52.3 46.7 5.1 5.563 0.25 300 7,288 6.88 9.75 2.06 2°-35' 0.54 /" x 3V4" 7.0 141.3 6.4 2,068 32,417 174.8 247.7 52.3 45.0 M16x83 3.2 159.0mm 6.250 0.25 300 9,204 7,56 10L31 2.06 2° 17' 0.48 M16 X 83 3.4 159.0 6.4 2,068 40,939 192.0 261.9 52.3 400 165.1mm 6.500 0.25 300 9,950 7.75 10.69 2.06 2° - 12' 0.46 M16 x 83 7.1 165.1 6.4 2,068 44,258 196.9 271.5 52.3 38.3 3.2 6" 6.625 0.25 300 10,336 7.94 10.69 2.06 2° -10'37.5 0.45 5/8" x 31/4" 7.1 168.3 6.4 2,068 45,975 201.7 271.5 52.3 M16x83 3.2 216.3mm 8.500 0.25 300 17,024 10.07 13.50 2.31 1° - 40' 0.35 M20 X 121 12.4 216.3 6.4 2,068 75,723 255.8 342.9 58.7 29.2 5.6 8.625 0.25 300 17,519 10.19 13.56 2.50 1°-40' 0.35 3/4"X4314' 14.5 8" 219.1 6.4 2,068 77,925 258.8 344.4 63.5 29.2 M20 121 6.6 10.750 0.25 250 22,679 12.69 16.38 2.63 1° -20' 0.28 1° X6V2' 28.0 10 273.0 6.4 1,724 100,876 322.3 416.1 66.8 23.3 M24 165 12.7 12.750 0.25 250 31,903 14.94 18.88 2.63 1° -7' 0.23 1"X6V2" 36.5 12" 323.9 6.4 1,724 141,905 379.5 479.6 66.8 19.2 M24 165 16.6 * Maximum available gap between pipe ends. Minimum gap = 0. t Maximum pressure and end load are total from all loads based on standard weight steel pipe. Pressure ratings and end loads may differ on other pipe materials and/or wall thickness. Contact Tyco Fire Products for details. See Fire Protection Equipment Submittal Sheet for Listing and Approval pressure ratings. ** Gold color coded metric bolt sizes are available upon request. Max End Gap and Deflection is for cut grooved standard weight pipe. Values for roll grooved pipe will be ½ that of cut grooved. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation \ 9001 instructions (11-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. A A = Total Hose Length, including Reducing Fitting and Special Shoulder Nipple 9 0 0 0 0 9 0 0 r, PS MIKE", - SUpplyNet .:FPSJ f. Technical Features Sizes Available :38" (965mm) and 58" (1473mm) long. 1" Inlet. '12," /3 or 3/4" outlet. Temperature Data : Maximum temperature : 300°F (149°C) Pressure Data: - Maximum Working Pressure: 200 PSI I 14kgf/cm2 - Test Pressure: 1000 PSI / 70.3kgf/c1112 (burst) Connections: - Inlet: 1" NPT male thread or DN25 BSP male thread. - Outlet: 1/2 NPT female thread or 3/4" NPT female thread IMPORTANT TECHNICAL NOTES: Minimum bend radius: 3" (76 mm) Maximum number of bends per hose: 3 Friction Loss Data : - Equivalent Length of DN25/1" Steel Pipe C@ (including 2 bends) (VEND - FPSJ 1000 = 34 ft. (10.4 meters) - FPSJ1500 = 43 ft. (13.1 meters) Flexible Sprinkler Connection - FPSJ Physical Data Nominal Size Inlet Hose Length Outlet Sprinkler Weight Reference inch metric Connection A (inch/mm) Connection (lbs/kg) /2 NPT FPSJ1000-50 1 2.5 / 1.13 38.0/965 3/4' NPT FPSJ1000-75 2.6 / 1.18 1,, NPT /2 NPT FPSJ1500-50 2.8/ 1.27 1 58.0/ - 3/4" NPT FPSJ1500-75 2.9/ 1.32 1" DN25 __________ '/2" NPT _ FPSJ1000B-50 2.5/1.13 38.01 965 3/4" NPT FPSJ1000B-75 2.6/ 1.18 1" BSP /S "NPT FPSJ1500B-50 2.8/1.27 580 / 14 3/4" NPT FPSJ1500B-75 1 2.9/1.32 Flexible Sprinkler Connection - FPSJ Materials List lte Description Material Specifications 1 1 Flexible Hose Corrugated Stainless Steel AISI 316L / AlSI 304 2 SlipNut Brass C3771 BC 3 ReducingFitting(Outlet) GalvanizedSteel SPPS 4 5 6 7 Special Shoulder Nipple (Inlet) Galvanized Steel Reducing Nipple Clamp & Bolt .Galvanized Ste& Bracket ChpAssernbly#1 GalvaruzedStee..SS.41 SprinklerSupportandCrossBarAssembly GalvanizedSteel SPPS SS4. SS4I 8 j BracketandClipAssembly#2 GalvanizedSteel _SS41 Worldwide Fire Protection Flexible Sprinkler Connections I FPSJ www.vikingcorp.com L......_ .. . .............................................. .. - ................ . .. ..... Manufactured br 'Jibing ScppiyNnt by Paradise induatiy Ltd. Refer In M,nuiactiirers datasheet specifications subject to change without notice LIN FPSJ. Installation Instructions Step 1: Insure the proper size hole has been cut into the ceiling tile at specified location. Install the special shoulder nipple into the line tee using the NPT threaded end. Make sure that the arrow and shoulder of the nipple are both pointing toward the direction of the sprinkler. Apply a non-hardening thread compound or Teflon tape to the male threads of the nipple. Make up the nipple with a pipe wrench for a leak-tight connection. Step 2: Install the appropriate frame style sprinkler head to the special reducer fitting on the flexible sprinkler connection. (Note: Flush and Concealed sprinklers cannot be installed before the assembly is installed into the sprinkler support.) Apply a non-hardening thread compound or Teflon tape to the male threads of the sprinkler. Tighten the sprinkler to the special reducer end of the flexible sprinkler reducer with the appropriate sprinkler head wrench. Hand tighten slip nut to reducer. Step 3: Connect the flexible sprinkler connection to the shoulder nipple - check for shoulder and arrow direction. Do not use any joint compound or thread compound on the fine threads of the shoulder nipple. Tighten the slip nut on the flexible connection to the shoulder nipple by hand (see cautions). The nipple and flexible connection are designed to seal in this fashion. Connect the sprinkler connection to the special reducer Cautions: - Slip Nut must be tightened by hand. Excessive force can damage the 0-ring. - Repeated bending of one portion of flexible connection before installation may cause breakage or loss of resisting. pressure. - Special shoulder nipple is composed of stainless hose and must not fitting by hand. Do not over tighten! Step 4: Attach the bracket and clip assembly, along with the sprinkler support and cross bar to the ceiling grid by hand using wing bolts provided. (Note: Bracket and Clip Assembly #6 is intended for use with pendent and recessed pendent frame style sprinklers. Bracket and Clip Assembly #8 is intended for use with Flush and Concealed style sprinklers.) Do not fully tighten wing bolts on the bracket and clip assembly until the sprinkler support is centered over the hole in the ceiling tile. Step 5: Install the flexible sprinkler connection assembly including the frame style sprinkler into the sprinkler support and adjust the assembly until the proper sprinkler location below the ceiling is obtained. Tighten the wing bolt in the sprinkler support and recheck wing bolts on the bracket and clip assembly for tightness. For Flush and Concealed sprinklers, do not install the sprinkler until after the drop has been inserted into the sprinkler support. Step 6 : Test the system for leaks per the Hydrostatic Test Procedure in the applicable Edition of NFPA 13. Note : This product is designed to be installed in accordance with recognized installation standards, such as NFPA 13 be used as a ground for welding. - When connecting the flexible connection assembly to the sprinkler piping, connect the nipple to the 0-ring first; then connect it to the sprinkler reducer. - For use in heated areas only. 9 9 0 0 Worldwide Fire Protection Flexible Sprinkler Connections / FPSJ www.vikingcorp.com Mann,Iactt,red for V.kjng bupplyNet by Prrodtor. Industry Ltd. Refer to Man,itacture.Cr datasheet. Speci&ationc subject to change ui,hnttt enricO. 1-301 -w Threaded T-301-W NPTx NPT 115 lb. WWP Bronze Angle Valves ncification Fire Protection Valve • Screw-in Bonnet • Integral Seat • Renewable Disc Resistant 175 PSI/12.1 Bar Non-Shock Cold Water CONFORMS TO MSS SP-80 • LJL/ULC LISTED* MATERIAL LIST PART SPECIFICATION Handwheel Nut 300 Series Stainless Steel Identification Plate Aluminum Handwheel Aluminum Commercial Alloy C38000 Stem Silicon Bronze ASTM B 371 Alloy C69430 Packing Gland Bronze ASTM B 62/ ASTM B 16t/ ASTM B 584 Alloy C84400 Packing Nut Bronze ASTM B 62/ ASTM B 584 Alloy C84400/ASTM B 16 Packing Non Asbestos Aramid Fibers w/Graphite Bonnet Bronze ASTM B 62 Alloy C83600 Disc Holder Nut Bronze ASTM B 62 Alloy C83600 Disc Holder Bronze ASTM B 62 Alloy C83600 Seat Disc EPDM Rubber (W) TFE(Y) Seat Disc Nut Bronze ASTM B 62t/ ASTM 896 Alloy C65100 w/SS washer Body Bronze ASTM B 62/13 584 Alloy C83600 * 21/2 and 3' size only. Not on 2' DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size A B H Weight Box Master In. mm. In. mm. In. mm. In. mm. Lbs. Kg. Qty. Ctn. (Hy. 11/4 32 2.19 56 6.13 156 2.19 56 3.71 1.69 1 10 11/2 40 2.38 60 7.19 183 2.38 60 5.54 2.52 1 10 2 50 2.25 57 7.25 184 2.25 57 6.72 3.05 1 10 "21/2 65 3.19 81 10.56 268 3.19 81 16.13 7.33 1 2 "3 80 3.88 86 11.13 283 3.88 86 21.72 9.87 1 2 UL/IJLC Listed for sizes for trim and drain use 11/4', 11N", 2" -- Sizes 21/2" and 3" supplied as 1-311-V with TEE seat disc. E NIBCO INC. WORLD HEADQUARTERS • 1516 MIDDLEOURY ST. • ELKHART, IN 46516.4740 • USA • PH: 1.800.2340227 TECH SERVICES PH: 1.888.446.4226 • FAX: 1.800.234.0557 • INTERNATIONAL OFFICE PH: +1.574.295.3221 • FAX: +1.574.295.3455 www.nibco.com 175 lb. WWP Bronze Globe Valves <'ncjfication Fire Protection Valve • Threaded Ends • Rubber Disc • Screw Over Bonnet 175 PSI/12.1 Bar Non-Shock Cold Water UL LISTED* MATERIAL LIST PART SPECIFICATION Handwheel Aluminum Handwheel Screw Carbon Steel Stainless Steel (1) Stem Bronze ASTM B 584 Alloy C84400 or ASTM B 505 Alloy C84400 Packing Nut Bronze ASTM B 584 Alloy C83600 or ASTM B 16 Packing Graphite Impregnated (Non Asbestos( Bonnet Bronze ASTM B 584 Alloy C84400 Body Bronze ASTM 8 584 Alloy C84400 Seat Disc EPDM Rubber Seat Screw Stainless Steel Pack Washer Sheet Brass KT-65-UL Threaded KT-65-UL NPTx NPT DIMENSIONS-WEIGHTS-QUANTITIES Dimensions Size A B Weight Box Master In. mm. In. mm. In. mm. Lbs. Kg. Uty, Ctn. Qty. 1/4 8 2.00 50 2.75 70 .48 .22 10 100 3/a 10 2.00 50 2.75 70 .45 .20 10 100 1/2 15 2.28 58 3,12 79 .68 .31 10 60 3/4 20 2.28 58 3.12 79 .74 .34 10 60 1 25 3.12 79 4.50 114 1.68 .76 5 25 "UI Listed for Trim and Drain use - sizes Ili% -YV".I Size 1/4" and IN supplied as Ifl.65 (9 NIBCO INC. WORLD HEADQUARTERS • 1516 MIDOLERURY ST. • ELKHART, IN 46516-4740 • USA • PH; 1.800.234.0227 TECH SERVICES PH; 1.888.446.4226 • FAX; 1,800.234.0557 • INTERNATIONAL OFFICE PH; +1.574.295.3221 • FAX; +1.574.295.3455 w.nibcc.com UNITED BRASS WORKS, INC. 714 S. Main St., Randleman, NC 27317 133 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com Isogofli tEiiTEHEfl cari Model 76 Gauge Test Valve 300 WOG @ 180 'Max 100% Pressure Tested Screwed Ends MATERIAL LIST NO. DESCRIPTION I MATERIAL Screw Stainless Steel 2 Hand Wheel Aluminum 3 Packing Nut Brass 4 0-Ring Nitrite 5 Washer Brass 6 Stem Brass 7 Body Bronze Size A 1.750 B 1.734 C 2.469 Ship Wgt. (lbs.) 0.34 Qty. Per Ctn. 25 Underwriters Laboratory listed and Factory Mutual approved Corrosion-resistant ABS case Heat-resistant polycarbonate push-in window Patented PowerFleXTM movement with polyester segment True Zero TM indication, a unique safety feature Ashcroft® fire protection sprinkler gauges are Underwriters Laboratory listed and Factory Mutual approved for fire protection sprinkler service. The case material on Type 1005P, XUL gauges is ABS. The 0-300 psi pressure range is used on "wet" systems where water is available to the sprinkler heads. The 0-80 retard to 250 psi pressure range is used on dry systems where the lines are filled with air pressure until system activation. The patented PowerFlex move- ment with polyester segment is designed to provide unequalled shock and vibration resistance resulting in superior performance and extended gauge life. 150 20 l0 90 210 - 240 30 2/0 V30, '- True Zero indication, a standard feature on these gauges, reduces the potential risk of installing a dam- aged gauge on your equipment. 1 10 1 1 : T Type no.: 1005P, XUL Operating Customized dials Accuracy: ASME B 40.1 Grade B temperature: —40°F to 150°F Other UL listed ranges on application (±3-2-3/0 of span) Connection: 1/4 NPT lower Size: 31/2" Ranges: 0-300 psi (water) Case: ABS (Polycarbonate blend) 0-80 retard to 250 psi (air) Ring: None UL 393 Listed, UL of Canada Listed and FM approved. Window: Polycarbonate, push-in Equivalent (single or dual Dial: Black figures on white back- scale) metric scales are ground available _______________ Pointer: Black, aluminum LISTED Bourdon tube: "C" shaped bronze Movement: Patented PowerF/ex FM with polyester segment . Socket: e Brass LOO1F0RTHESEAC40CY Restrictor: None Select: 35 W 1005 P H 021 XUL 300# Dial Size: 31/ Patented PowerFIexTM Movement Case Type Number: 1005 Case Type Material: ABS Socket Material: Brass Connection Size/Location: 1A NPT lower UL listed, FM approved Range: 300 psi Consult factory for guidance in product selection Phone (203) 385-0217, Fax (203) 385-0602 or visit our web site at www.ashcroft.com Instruments The AGF Manufacturing Inc. Model 1011A TESTAIIDRAIN matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system, with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves (see reverse). The Model 1011A TESTANDRAIN is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses, and is 300 PSI rated. Available in a full range of sizes from 3/4" /4 to 2' NPT and BSPT, with all specifiable orifice sizes 3/8", /ie", ½", 17/32", /8" (ELO), 34" (ESFR), and K25 as required by NFPA 13, 2007 Edition (see reverse). The included ULJFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the difficult problem of providing the relief valve with a convenient drainage-piping outlet. Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent unintentional alarm activation. NOTE: It is important to rote that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. - - . . ... . ... TC DRJ 4. IIII 1jIp MATERALt Handle: Steel Stem: Rod Brass Ball: C.P. Brass Body: Bronze Valve Seat: Impregnated Teflona Indicator Plate: Steel Relief Valve: Bronze Bypass Fittings: Brass Bypass Tubing: Nylobraid UL and ULC Listed: (EX4019 & EX4533) FM Approved NYC-BSA No. 720-87-SM H J LL *L 9 ED Orifice Size Available: 3/8", 7A6', 1/2 , 17/32, ELO (5/")*, ESFR (3/4")*, & K25** SIZE A B C D E F G H 3/4" 79/i&' 1½" 23/16 35/8 33/8 113/16 49A6' 63i" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 1 7A6' 11/2 " 23/16" 3/8" 33/8" 113A6" 49/16" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715/16 111/16" 29/16 41/4 35," 115/16 59/16 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 11/2 815/16" 113/i& 31/4" 51/16" 3/8" 25/8 81/4 107/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2" 815/io" 113/16 31/4 51/16 37/8 2/8' 81/4" 10/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) * Available on 11/4" to 2" size units only ** Available on 11/2" and 2" size units only From the 2007 Edition of NFPA 13 Chapter 8.16.2.4.1" Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.1 6.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterf low alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3" A relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve AGF Manufacturing Inc. Job Name:____________________________ 100 Quaker Lane, Malvern, PA 19355 T. 610-240-4900 / F: 610-240-4906 Architect:____________________________________ E-mail: info@testandrain.com Engineer: www.testandrain.com Contractor: tLICJ3 /Fire & Building / Products Technical Services: Tel: (800)381-9312/ Fax: (800) 791-5500 Series TY-FRB - 2.8, 4.2, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pendent Sprinklers described in this data sheet are quick response - standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TYII3I - Upright 2.8K, 1 12"NPT TY1231 - Pendent 2.8K, 112"NPT TY2131 - Upright 4.2K, 112"NPT TY2231 - Pendent 4.2K, 1/2"NPT TY3131 - Upright 5.6K, 1/2'NPT TY3231 - Pendent 5.6K, 112"NPT TY4131 - Upright 8.0K, 314"NPT TY4231 - Pendent 8.01K, 3/4"NPT Page 1 of 10 APRIL, 2006 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 7/16(11,1 mm) NOMINAL MAKE-IN 1/2" ** NPT 6* 'Page k of 10 TFPI7I ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING 1/2" ** NOMINAL SURFACE MAKE-IN 2-1/4" NPT (57,2 mm) 1-9/16" SSPDEFLECTOR* L (39,7 mm) STYLE 10or20 RECESSED SSU* ESCUTCHEON DEFLECTOR (11,1mm) I NOMINAL I I 7/16" MAKE-IN 2-3/16" WRENCH (55,6 mm) / FLATS 1/2" NPT** I 2-7/8' (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5 - Compression 7- Bushing orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 1 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT T_ 2-3/16" (55,6 mm) STYLE 10 0r20 RECESSED SSU* ESCUTCHEON DEFLECTOR / 7/16" ENCH (11,1 mm) I [tx!zii \ NOMINAL I E-IN 2-3/16" _______ (55,6 mm) _w I FLATS 1/2" NPT** SSP DEFLECTOR* H— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3- Sealing 4 - Bulb 6- Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP11 Page 3 of 10 ESCUTCHEON 7/16" (11,1 mm) STYLE 10 0120 PLATE SEATING ,, ** NOMINAL RECESSED SSU SURFACE NPT MAKE-IN ESCUTCHEON DEFLECTOR (55, mm) NOMINAL (1 11 1 NOM NAL 1-1/2" LS I 17,16J SSP DEFLECTOR* FLATS 3 2-7/8(73,0 mm) DIA. 1/2' NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 3 QUICK RESPONSE SERIES TV-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6K-FACTOR, 1/2 INCH NPT ESCUTCHEON 1/2(12,7mm) STYLE 30 0r40 PLATE SEATING ** NOMINAL RECESSED SSU* SURFACE MAKE-IN ESCUTCHEON NPT DEFLECTOR 1/2" 6* 2-5/16 (12,7 mm) ____________ NOMINAL (58,7 mm) HHI _ MAKE-IN 2 1 1-9/16" WRENCH (52mm) 3 FLATS (39,7 mm) SSP DEFLECTOR* 2-7/8 (73,0 mm) DIA. 3/4 NPT** PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3 - Sealing 4- Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT Page 4 of 10 TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME PLATED I WHITE*** POLYESTER 2.8 PENDENT (TY1231) and UPRIGHT (TYII3I) 1357/57°C Orange 1,23,5 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 286°F/141°C Blue 1/2 NPT RECESSED PENDENT (TY1231)* Figure 5 135°F/57°C Orange 1, 2, 5 155°F/68°C Red 175F/79°C Yellow 200°F193°C Green RECESSED PENDENT (TY1231)** Figure 6 155°F/68°C 175°F/79°C 135°F157°C AGreen 200°F/93C 4.2 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY2131) 135°F157°C Orange 1,2 155°F168°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT (TY2231)* Figure 7 135F/57C Orange 155°F168°C Red 175F/79°C Yellow 200°F/93C Green RECESSED PENDENT (TY2231)** Figure 8 135°F/57°C Orange 155°F/68*C Red 175°F179°C Yellow 200°F193°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. * Installed with Style 10(1/2" NPT) or Style 40 (3/4' NPT) 3/4 Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/ps1112 (40,3 LPM/ba1112) K = 4.2 GPM/psi112 (60,5 LPM/bar112) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame ............Bronze Button ........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ..............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. -I— TFPI'71 Page 5 of 10 SPRINKLER FINISH (See Note 8) K TYPE TEMP. BULB LIQUID NATURAL BRASS I CHROME I PLATED IPOLYESTER WHITE' LEAD COATED 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2,34,5,6,7 1,2,3,5 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286F/141°C Blue 1/2" NPT RECESSED PENDENT (TY3231)* Figure 9 135°F/57°C Orange 1,2,4,5 N/A 155°F168°C Red 175°F/79°C Yellow 200°F193°C Green RECESSED PENDENT (1Y3231)** Figure 10 135°F/57°C Orange 1,2,3,4,5 I I I I 1,2,4,5 I Green N/A 155°F/68°C Red 175°F/79°C Yellow 200F/93°C 8.0 PENDENT (TY4231) and UPRIGHT (TY4131) 135°F/57°C Orange 1,2, 3,4, 5, 6,7 1,2,5 155°F/68°C Red 175°F/79°C Yellow 2007/93°C Green 286F/141°C Blue 3/4,' NPT RECESSED PENDENT (TY4231)* Figure 11 135°F/57°C Green 1, 2, 4, 5 N/A 155F/68°C Orange 175°F/79°C Red 200F/93°C Yellow RECESSED PENDENT (TY4231)** Figure 12 135°F/57°C Orange 1,2,3,4,5 N/A 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4' NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. *** Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS Page 6 of 10 TFPI7I SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD PLATED IBRASS POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 1/2 RECESSED PENDENT NPT (TY323) PENDENT (1Y4231) and 4.2 UPRIGHT (TY4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (TY3131) OR 1/2 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY323) (SEE NOTE 1) N/A PENDENT (1Y4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) 3/4,, RECESSED PENDENT NPT (TY4231) N/A NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135"F/57"C to 3/32 inch (2,4 mm) for the 286"F/141C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendent sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 13). With reference to Figures 1, 2, 3, and 4, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench fiats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 14). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench fiats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP11 - 2-7/8 DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4(6,4 mm) I FACE OF MOUNTING SPRINKLE PLATE FITTING R _________ (3,2 mm) MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 13/16(20,6 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE FITTING 118" (3,2 mm) MOUNTING I SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 3/4" (19,1 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Page 7 of 10 - 2-7/8" DIA. 1/2±1/8" (73,0 mm) 112" (12,7 mm) r (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4mm) FACE OF qR 572 MOUNTING I SPRINKLE -PLATE FITTING 1 (32m MOUNTIN SURFACE I CLOSURE SERIES (33,3 mm) TY-FRB 1-1/16" (27,0 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) [ (12,7±3,2 mm) 2-1/4" DIA. 1/4(6,4mm) FACE OF MOUNTING (57,2 mm) I I FITTING 1/8" I (32m_j SPRINKLER PLATE MOUNTING 7 SURFACE SERIES 1-1/4(31,8 mm)1 CLOSURE TYFRB 1" (25,4 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects,' otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random 'Page 8 of 10 - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) 3/4" (19,1 mm) (15,9±6,4 mm) - 2-1/4" DIA. 1/4(6,4mm) I FACE OF 57,2 mm) MOUNTING SPRINKLER PLATE FITTING 1/8" (3,2 mm) ow MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) I CLOSURE TYFRB 3/4" (19,1 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4(19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4(6,4mm) I FACE OF (57,2 mm) MOUNTING PLATE SPRINKLER FITTING I __________________ ___________ _ ___________ (32 m_j __ _ _j MOUNTING CLOSURE SERIES SURFACE ________________ TY-FRB 13/16(20,6mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT TFPI7I - 2-7/8" DIA. 1/2±1/8" 1/2(12,7 mm) (73,0 mm) (12,7±3,2 mm) 2-1/4" DIA. 114" (6,4 mm) SPRINKLER 1/7- PL ATE FACE OF 572 mm) MOUNTING /8" FITTING (32mm) MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TYFRB 1" (25,4 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 1/2±1/8" (73,0 mm) 1/2" (12,7 mm) (12,7±3,2 mm) 2-1/4" DIA, 1/4" (6,4 mm) (57,2 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 1181, / (3.2 mm) PH:, 1-5/16" (33,3 mm) 1-1/16" (27,0 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT I \ - MOUNTING SURFACE CLOSURE SERIES TY-FRB sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 13 W-TYPE 6 SPRINKLER WRENCH tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP111 Page 9 of 10 P/N 57-XXX-X-XXX I L MODEUSIN 330 2.8K UPRIGHT (1/2"NPT)l TY1131 331 2.8K PENDENT (1/2'NPT) TY1231 340 4.2K UPRIGHT (1/2'NPT) TY2131 341 4.2K PENDENT (1/2'NPT) TY2231 370 5.6K UPRIGHT (1/2'NPT) TY3131 371 5.6K PENDENT (1/2"NPT) TY3231 390 8.0K UPRIGHT (3/4"NPT) TY4131 391 8.0K PENDENT (314'NPT) TY4231 I I I SPRINKLER L 135 1 NATURAL BRASS 4 WHITE POLYESTER 3 WHITE (RAL9010)* 9 CHROME PLATED 7 LEAD COATED I 155 175 200 286 TEMPERATUR RATING 155°F168°C 175*F/790C 200°F/93°C 286°F/141°C * Eastern Hemisphere sales only. TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify*) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. tLICU /Fire & Building / )Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB - 56 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 5.6 K-Factor, Horizontal and Vertical Sidewall Sprin- klers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commercial occupan- cies such as banks, hotels, shopping malls, etc. They are designed for in- stallation along a wall or the side of a beam and just beneath a smooth ceil- ing. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desir- able. The recessed version of the Series TY-FRB Horizontal Sidewall Sprinkler is intended for use in areas with a finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjust- ment from the flush sidewall position, or a two-piece Style 20 Recessed Es- cutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush sidewall position. The adjust- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail: to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 ment provided by the Recessed Es- cutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TY3331 - Horizontal TY3431 - Vertical APRIL, 2006 Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete ap- proval information including corrosion resistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K = 5.6 GPM/p5i112 (80,6 LPM/bar112) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table A. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. TFPI76 Page 2 of 6 TFPI76 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB LIQUID NATURAL I BRASS CHROME PLATED WHITE*** POLYESTER LEAD COATED 5.6 1/2" HORIZ. SIDEWALL (TY3331) 135°F/57°C Orange 1,2,3,4,9,10 __________ 1,2,3,9 1,2,3,9 155°F/68°C Red 175°F/79°C Yellow 200F/93°C Green 286°F/141°C Blue NPT RECESSED HORIZ. SIDEWALL (1Y3331)* Figure 3 135°F/57°C Orange 1,2,4,9,10 1, 2,9 N/A 155F/68°C Red 175°F/79°C Yellow 200°F/93°C Green RECESSED HORIZ. SIDEWALL (TY3331)** Figure 4 135°F/57°C Orange 1,2,3,4,9 N/A 155°F/68C Red 175°F/79C Yellow 200F/93°C Green 5.6 1/2" NPT - VERTICAL SIDEWALL (TY3431) Installed Pendent or Upright 135°F/57°C Orange 5,6,7,8,9 5,6,7,9 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green 1286*F/141'Cl Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Listed by Underwriters Laboratories Inc. for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4t0 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Listed by Underwriters Laboratories for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06 & 007a/04) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) 3/4" Total Adjustment Recessed Escutcheon. ** Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon. Frame and deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORA TORY LISTINGS AND APPROVALS Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze HSW Deflector ........Bronze VSW Deflector ........Copper Patents U.S.A. 5,610,263 Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. * Temperature rating is DEFLECT( indicated on deflector or HAT adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. 7/16' (11,1 mm) NOMINAL MAKE-IN - 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) STYLE ESCUTCHEON 10 or 20 RECESSED 2-7/8"2-7/8" DIA. JJ (73,0 mm) 9/16" (14,3 mm) 1-13/16" 46,0 mm) CENTERLINE OF SPRINKLER WATERWAY WRENCH 1/2" ** FLATS NPT 1 - Frame Button Sealing Assembly Bulb 5 - Compression Screw 6 - Deflector ESCUTCHEON PLATE SEATING SURFACE TFPIV6 Page 3 of 6 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD BRASS PLATED POLYESTER I COATED - HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3331) OR 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) RECESSED HORIZ. SIDEWALL (1Y3331) NIA 5.6 1/2' (SEE NOTE 1) NPT VERTICAL SIDEWALL (TY3431) 175 PSI (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B, MAXIMUM WORKING PRESSURE Design Criteria The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers are in- tended for fire protection systems de- signed in accordance with the stand- ard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the re- quirements of NFPA 13, and FM Ap- proval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE 7/16" Page 4 of 6 TFPI 76 Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286F/141C temperature ratings. A leak tight 1/2 inch NPTsprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. Higher levels of torque may distort the sprinkler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the follow- ing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of water- way perpendicular to the back wall and parallel to the ceiling. The word 'TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2, the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series TY-FRB Recessed Hori- zontal Sidewall Sprinklers must be installed in accordance with the follow- ing instructions. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. ESCUTCHEON PLATE SEATING SURFACE NPT 2-3/16" (55,6 mm) f J11i__f•Jzf 1-1/2" I I WRENCI (38,1 mm) I K A I FLATS SHOWN PENDENT 1 - Frame 3-Sealing 2 - Button Assembly Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 20 Clo- sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling SHOWN CROSS UPRIGHT SECTION 4-Bulb 6- Deflector 5 - Compression 7- Ejection Spring Screw Care and Maintenance The Series TY-BFR Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion IiI1 Temperature rating is indicated on deflector or adjacent to orifice seat on frame. **Pipe thread connections per ISO 7/1 can be provided on special request. FIGURE 2 5.6 K-FACTOR QUICK ESPONSE SERIES TY-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS TFPITB Page 5 of 6 - 5/8±1/4 (15,9±6,4 mm) MOUNTING FACE OF SURFACE _ SPRINKLER FITTING CLOSURE 2-7/8 DIA. (73,0 mm) SERIES DIA. mm) MOUNTING PLATE 1/8 (3,2 mm) 1-1/4" (31,8 mm) 3/4(19,1 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) FIGURE 3 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON --1 - 1/2±1/8" I (12,7±3,2 mm) MOUNTING FACE OF SURFACE _- SPRINKLER FITTING CLOSURE 2-7/8" DIA. (73,0 mm) SERIES 2-1/4' DIA. (57,2 mm) MOUNTING PLATE 1/8' (3,2 mm) 1-1/4" (31,8 mm) 1/2(12,7mm) 1" (25,4 mm) 1/4" (6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON AA" NCH RECESS (END USED FOR 112 NPT MODELS) FIGURE 5 W-TYPE 6 SPRINKLER WRENCH WRENCH -- RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH must be replaced Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the 'Page '6 of 6 TFPI76 PIN 57-XXX-X-XXX I MODEL/SIN 378 HORIZONTAL SIDEWALL TY3331 375 VERTICAL SIDEWALL TY3431 I L SPRINKLER I 135 155 175 200 286 TEMPERAIUb RATING 1 NATURAL BRASS 135°F/57°C 4 WHITE POLYESTER 155°F/68°C 3 WHITE RAL9010 175°F 179°C 9 CHROME PLATED 200°F/93°C 7 LEAD COATED 286°F/141°C TABLE C * Eastern Hemisphere sales only. PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness fora par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Horizontal Sidewall or Vertical Sidewall) Sprinkler with (specify type of finish or coating), P/N (specify from Table C). Recessed Escutcheon: Specify: Style (10 or 20) Recessed Escutcheon with (specify*) finish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 tqCI7 /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series EC-8 - 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description The Series EC-8 Extended Coverage Pendent Sprinklers are decorative glass bulb sprinklers designed for use in light hazard occupancies. They are intended for use in automatic sprinkler systems designed in accordance with standard installation rules (e.g., NFPA 13) for a maximum coverage area of 400 ft2 (37,2 m2), as compared to the maximum coverage area of 225 ft2 (20,6 m2) for standard coverage sprin- klers used in light hazard occupancies. The recessed version of the EC-8, in- tended for use in areas with a finished ceiling, uses either the two-piece Style 30 or 40 Recessed Escutcheon. The Style 30 Recessed Escutcheon pro- vides up to 1/2 inch (12,7 mm) of total adjustment from the flush pendent po- sition, whereas, the Style 40 provides 3/4 inch (19,1 mm) of vertical adjust- ment from the flush pendent position. The adjustment provided by the Re- cessed Escutcheons reduces the ac- curacy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-8 Extended Coverage Sprinklers described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the per- formance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number 1Y4232 - Pendent, 8.01K TY4232 is a redesignation for C4232 JANUARY, 2005 Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 3/4 inch NPT Discharge Coefficients K = 8.0 GPM/ps1112 (115,2 LPM/bar112) TFP223 Page2 of 6 TFP223 Components: 3/4 ** ESCUTCHEON PLATE 1 - Frame I NPT SEATING SURFACE 2 - Button 3 Sealing Assembly 2 ] 5 - Compression 2-1/8 Screw 3 —fhJ)lt1,JØ1 I (54,0 mm) 6 -Deflector* 1/2" * Temperature rating is 4 (12,7 mm) NOMINAL 1-7/16 indicated on Deflector. MAKE-IN / (36,5 mm) ** Pipe thread connections per ISO -- - ........ 7/1 can be provided * 6 on special request. FIGURE 1 SERIES EC-8 (TY4232) EXTENDED COVERAGE PENDENT SPRINKLERS SPRINKLER FINISH (See Note 4) HAZARD TYPE TEMP. BULB NATURAL I CHROME LIQUID BRASS PLATED FWH LYESTER LIGHT PENDENT 135°F/57°C Orange Refer to Table B for UL and C-UL 1,2,3,5 155°F/68°C Red ________________ REC. PENDENT 135°F/57°C Orange Sensitivity Rating and Refer to Table C for FM W/ Style 30 Esc. 1,2,3,5 155°F/68°C Red ________________ REC. PENDENT 135°F/57°C Orange Sensitivity Rating WI Style 40 Esc. 1, 2, 5 155°F/68°C Red NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Approved by Factory Mutual Research Corporation (FM). Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Approved by the City of New York under MEA 113-04-E. *Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS (Refer to the Design Criteria Section) Temperature Ratings 135°F/57°C and 155°F/68°C Finish Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, and Brass Plated Physical Characteristics Frame .............Bronze Button .............Bronze Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ........Glass (3 mm dia.) Compression Screw ......... .......Bronze Deflector ............Brass t Registered trademark of DuPont Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The Series EC-8 Extended Coverage Pendent Sprinklers must only be in- stalled in accordance with the applica- ble UL and C-UL Listing or FM Ap- proval requirements as indicated below. Only the Style 30 or 40 Re- cessed Escutcheon is to be used for recessed installation, as applicable (Ref. Table A, B, and C). UL and C-UL Listing Requirements The Series EC-8 Sprinklers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and haz- ard group for all of the sprinklers in the design area. With respect to heat sensitivity, the Series EC-8 Sprinklers can be used with unobstructed construction con- sisting of flat, smooth ceilings (in- cluding bar joists) with a maximum pitch of one in six as defined and permitted by NFPA 13. The minimum allowable spacing be- Page 3 of 6 TFP23 135°F 155°F AREA STYLE 16x16 Pendent OR OR 16 x 16 Style 30 Recessed OR OR 16 x 16 Style 40 Recessed OR OR 18 x 18 Pendent OR OR 18 x 18 Style 30 Recessed OR SR 18 x 18 Style 40 Recessed OR SR 20x20 Pendent OR SR 20 x 20 Style 30 Recessed OR SR 20 x 20 Style 40 Recessed SR SR OR: Quick Response SR: Standard Response N/A: Not Applicable TABLES SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 135°F 155°F AREA STYLE 16 x 16 Pendent OR OR 16 x 16 Style 30 Recessed OR N/A 16 x 16 Style 40 Recessed N/A N/A 18 x 18 Pendent OR OR 18 x 18 Style 30 Recessed OR N/A 18 x 18 Style 30 Recessed N/A N/A 20x20 Pendent OR OR 20 x 20 Style 30 Recessed OR N/A 20 x 20 Style 40 Recessed N/A N/A OR: Quick Response SR: Standard Response N/A: Not Applicable TABLE C SENSITIVITY RATING FOR FM APPROVAL OF SERIES EC-8 SPRINKLERS Installation The Series EC-8 Sprinklers must be installed in accordance with the follow- ing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.Ibs. (13.4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leak- age or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment of an Escutcheon Plate by under- or over-tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position. Step 2. After installing the Style 30 or 40 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads, and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten pendent sprin- klers using only the W-Type 3 (End A) Sprinkler Wrench. Wrench tighten the recessed pendent sprinklers using only the W-Type 4 Sprinkler Wrench. The wrench recess of the applicable sprinkler wrench (Ref. Figure 4 and 5) is to be applied to the sprinkler wrench flats (Ref. Figure 1). tween the Series EC-8 Sprinklers, to prevent cold soldering, is 8 feet (2,4 m). 4. The Series EC-8 Sprinklers are to be installed in accordance with all other requirements of NFPA 13 for ex- tended coverage pendent sprin- klers. FM Approval Requirements The Series EC-8 Extended Coverage Sprinklers are to be installed in ac- cordance with the applicable Factory Mutual Loss Prevention Data Sheet. Information provided in the FM Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spacing, and deflector-to ceiling distance. Page '4 of 6 DESCRIPTION AREA GPM PSI TV4232 (K=8.0) PENDENT 16 x 16 26 10.6 18x18 33 17.0 20x20 40 25.0 itt. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm = 3.785 1pm 1 psi = 0.06895 bar 1 gpmlft2 = 40.74 mm/mm TABLED FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-8 SPRINKLERS 2-7/8" DIA. - 1/2±1/8' (73,0 mm) 1/2" (12,7 .mm).. (12,7±3,2 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) 1/811 FITTING (3,2 mm) MOUNTING SPRINKLER w MOUNTING CLOS / / PLATE 1-1/4" (31,8 mm) 1" (25,4 mm) FIGURE 2 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON - 2-7/8" DIA. 9/16±1/4' (73.0 mm) 3/4(19,1 mm) (14,3±6,4 mm) 2-1/4' DIA. 1/4' (6,4 mm) FACE OF (57.2 mm) SPRINKLER c- 1/8' FITTING (3,2 mm) MOUNTING TING MOUNURFACE PLATE . CLOSURE 1-5/16" (33,3 mm)_ 13/16" (20,6 mm) FIGURE 3 SERIES EC-8 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON TFP223 "FITTING SIDE" TOWARDS SPRINKLER FITTING / WRENCH RECESS (END FIGURE 4 W-TYPE 3 SPRINKLER WRENCH WRENCH RECESS - WRENCH LUGS FIGURE 5 W-TYPE 4 RECESSED SPRINKLER WRENCH Care and Maintenance The Series EC-8 Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authorities and all personnel who may be affected by this action must be no- tified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to TFP223 Page 5 of 6 corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the. sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES .EXPRESS DR r.JIg;(.3JfJA'Ii'i!h1M Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Refer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: TY4232, (specify temperature rating), Extended Coverage Pendent Sprinkler with (specify finish), P/N (specify). 135FJ57C Natural Brass .............PSN 50-801-1-135 White Coated .............PSN 50-801-4-135 White (RAL9O1O).. ......... PSN 50-801-3-135 Chrome Plated .............SN 50-801-9-135 155F/68°C Natural Brass ... .......... PSN 50-801-1-155 White Coated .............PSN 50-801-4-155 White (RAL9O1O) ........... PSN 50-801-3-155 Chrome Plated ............PSN 50-801-9-155 *Eastern Hemisphere sales only. Recessed Escutcheon: Specify: Style (30 or 40) Recessed Escutcheon with (specify finish), P/N (specify). Style 30 Recessed Escutcheon Chrome Plated ............PSN 56-705-9-011 White Color Coated ........PSN 56-705-4-011 White (RAL9O1O). .......... PSN 56-705-3-011 Brass Plated ..............PSN 56-705-2-011 Style 40 Recessed Escutcheon Chrome Plated ............PSN 56-700-9-010 White Color Coated ........PSN 56-700-4-010 White (RAL9O1O). .......... PSN 56-700-3-010 Brass Plated ..............PSN 56-700-2-010 Eastern Hemisphere sales only. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1 -001 Specify; W-Type 4 Recessed Sprinkler Wrench, P/N 56-875-4-001 tqCJ3 /Fire & Building I Products Technical Services: Tel: (800)381-9312/ Fax: (800) 791-5500 Model GI & G4 Sprinkler Guards Model GI/SI & G4/S3 Guards with Shields Series TY-B, TY-FRB, TY-L, and TY-FRL Sprinklers General Description The Model 31 & 34 Sprinkler Guards (Ref. Figure 1) are designed for use with specific types of Series TY-B, TY- FRB, TY-L, and TY-FRL Sprinklers that may be located in areas that make them susceptible to mechanical or physical damage. Table A provides compatibility details. The Model G1/S1 & G4/S3 Sprinkler Guards with Shields (Ref. Figure 2), in addition to providing protection from mechanical or physical damage, shields the sprinkler from water spray of higher elevation sprinklers (e.g., rack storage sprinkler installations). When the G1/S1 and 34/S3 are used with the Series TY-B, TY-FRB, TYL, and TY-FRL Sprinklers shown in Table A, the assemblies form Upright Inter- mediate Level Sprinklers intended for use in fire sprinkler systems designed in accordance with the standard instal- lation rules recognized by the applica- ble Listing agency (i.e., UL Listing is based on NFPA requirements). The 31 and G4 are a redesignation for the Gem F938 & F937, and the 31/S1 & 34/S3 are a redesignation for the Gem F938/Q-76 and F937/Q-75. WARNINGS The Model 31 8 G4 Sprinkler Guards and Gi/SI & G4/S3 Sprinkler Guards with Shields described herein must be installed and maintained in compli- ance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the integ- rity of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted relative to any questions. Technical Data Approvals UL and C-UL Listed. FM Approved. (Refer to Table A) Finishes Red Painted and Zinc Chromate Physical Characteristics Welded assembly fabricated from carbon steel Design Criteria In accordance with the requirements of the NFPA, sprinkler guards shall be listed. Guards are only listed for use with specified sprinklers; therefore, the 31, G4, G1/S1, and 34/S3 must only be used with the Series TY-B, TY-FRB, TY-L, and TY-FRL Sprinklers shown in Table A. Installation The Models 31, G4, G1/S1, and G4/S3 are to be installed as follows: Step 1. The Gi, G4, 31/S1, or G4/S3 is to be mounted on the sprinkler after the sprinkler has been installed in ac- cordance with its applicable technical data sheet. Step 2. With the Clips loose, first spread the two halves of the Sprinkler Guard just enough to pass by the sprinkler deflector from the side. Then, once again spread the two halves of the Sprinkler Guard just enough to pass over the sprinkler "thread relief" or "wrenching area", as applicable, portion of the sprinkler. (Refer to Table A, as well as Figures 1 and 2.) Step 3. With the Sprinkler Guard posi- tioned on the "thread relief" or "wrenching area" portion of the sprinkler, as applicable, engage the Clips and then slide the Clips until they GI . G4 GIISI Page 1 of 4 DECEMBER, 2003 TFP780 Page of 4 TFP78O SERIES SPRINKLER TFP SIN GEM SIN STAR SIN SPRINKLER TYPE SPRINKLER K-FACTOR MOUNTING LOCATION GUARD MODEL (APPROVALS) GUARD WITH SHIELD MODEL (APPROVALS) TY1151 G7530 - Upright 2.8 Thread Relief Gi (1) N/A TY1251 G7531 - Pendant 2.8 Thread Relief G1 (1) N/A TY3151 G7570 - Upright 5.6 Thread Relief Gi (1,2) G1/S1 (I) TY3251 TY4851 G7571 G7560 - Pendent Upright 5.6 8.0(1/2'_NPT) Thread Relief Thread Relief Gi (1,2) GI (1,2) N/A N/A TYB TY4951 G7561 - Pendant 8.0 (1/2' NPT) Thread Relief GI (1,2) N/A TY4151 G7590 - Upright 8.0 (3/4 NPT) Thread Relief Cl (1,2) Cl/Si (1) TY4251 G7591 - Pendant 8.0 (3/4' NPT) Thread Relief Gi (1, 2) N/A TY3351 G7578 - HSW 5.6 Thread Relief G4 (1) N/A TY3451 G7575 - VSW 5.6 Thread Relief G4 (1) N/A TY1131 G7330 Upright 2.8 Thread Relief G (1) N/A TV-i 231 G7331 - Pendant 2.8 Thread Relief Cl (1) N/A TY3131 TY3231 G7370 G7371 - - Upright Pendant 5.6 5.6 Thread Relief Thread Relief G1 (1,2) Cl (1,2) Cl/Si (1) N/A TY-FRB TY4131 G7390 - Upright 8.0 (3/4' NPT) Thread Relief Gi (1,2) Cl/Si (1) TY4231 G7391 - Pendent 8.0 (3/4' NPT) Thread Relief G (1) N/A TY3331 G7378 - HSW 5.6 Thread Relief G4 (1) N/A TV3431 G7375 - VSW 5.6 Thread Relief G4 (1) N/A TY3111 C3111 S1800 Upright 5.6 Wrench Area Cl (2) & G4 (1) G4/S3 (1) TY3211 G3112 S1801 Pendent 5.6 Wrench Area Cl (2) & G4(1) N/A TY3311 G3113 S1803 HSW 5.6 Wrench Area - N/A TY-L TY4811 - S1805 Upright 8.0(1/2 NPT) Wrench Area G4 (1,2) G4/53(1) TY4911 - S1806 Pendant 8.0 (1/2 NPT) Wrench Area G4 (1) N/A TY4111 G3101 S1810 Upright 8.0 (3/4' NPT) Wrench Area G4 (1,2) G4/S3(1) TY4211 G3102 S1811 Pendent 8.0 (3/4 NPT) Wrench Area G4 (1) N/A TY1121 TY1221 G8973 C8971 S1879 S1880 Upright Pendant 2.8 2.8 Wrench Area Wrench Area C4(1) G4 (1) N/A N/A TY-FRL TY3121 TY3221 G8974 G8972 S1864 S1865 Upright Pendant 5.6 5.6 Wrench Area Wrench Area G4 (1, 2) G4(1) G4/53 (1) N/A TY3321 G8946 S1878 HSW 5.6 Wrench Area G4 (1) N/A TY4121 G8174 S1866 I Upright 8.0 (3/4' NPT) Wrench Area G4 (1,2) G4/53 (1) TY4221 I G8172 S1867 I Pendant 1 8.0(3/4 NPT) Wrench Area G4 (1) N/A APPROVALS & NOTES: Listed by Underwriters Laboratories Inc. Approved by Factory Mutual Research Corporation, N/A Not Applicable for noted sprinkler. - No SIN, Listing or Approval TABLE A -LABORATORY LISTINGS AND APPROVALS seat against the Base to complete the installation as shown in Figures 1 and 2. To help assist with the sliding of the Clips the Guard Installation Tool may be used as shown in Figure 3. In addi- tion, pliers can be used to facilitate the final seating of the Clips. NOTES The Clips must seat against the Base in order to be considered fully seated and in order to complete the installa- tion. The G1,G4, Gi/Si, and G4/S3 may be located in any position relative to the sprinkler frame arms. Shown with Series TY-FRL Sprinkler WARD CLIP IGAGED) BAR SPRINKLER WRENCH AREA ENGAGED BY BASE PLATE BASE PLATE 7 3-7/16" (87,3 mm) BAR WARD CLIP IGAGED) Page 3 of 4 2-7/8" DIA. (73,0 mm) Model G4 Guard Model Gi Guard Shown with Series TY-FRB Sprinkler 7 3-1/2" (88,9 mm) BASE 2-7/8" DIA PLATE (3 mm) \ SPRINKLER \ THREAD RELIEF ENGAGED BY BASE PLATE ?4 I. IVIUUi ua. U With Model Si Shield Shown with Series TV-B Sprinkler Shown with Series TY-L Sprinkler Model G4 Guard With Model S3 Shield 2-7/8' DIA. (73,0 mm) GUARD CLIP BAR 3AR SHIELD IlTH REW 5HIELD /ITH REW 2-3/8" (60,3 mm L (ENGAGED) B/ P LA I SPRINKLER WRENCH AREA ENGAGED BY BASE PLATE UARD CLIP (ENGAGED) TFP78O SPRINKLER THREAD RELIEF ENGAGED BY / BASE PLATE / 2-7/8" DIA. BASE (73,0 mm) PLATE FIGURE 1 MODEL Gi AND G4 SPRINKLER GUARDS - DIMENSIONS 4' DIA. 4-3/4" DIA. (101,6 mm) (120,7 mm) FIGURE 2 MODEL G1/S1 AND G4/S3 SPRINKLER GUARDS WITH SHIELDS - DIMENSIONS Care and Maintenance The Models Gi, G4, G1/S1, and G4/S3 do not require any regularly scheduled maintenance; however, proper installation of the Sprinkler Guards should be verified during the annual visual inspection of the sprin- klers. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire Products. No war- ranty is given for products or FIRST FIRST CLIP FULLY LIP FULLY ENGAGED BAR SLOT CLIP INSTALLATION TOOL (SHIPPED WITH GUARDS) Page4 of 4 WITH SPRINKLER PROPERLY INSTALLED, CAREFULLY SPREAD BASE PLATES APART AND FIT ONTO SPRINKLER AT APPROPRIATE MOUNTING LOCATION PER TABLE A AND FIGURES 1 or 2 BASE PLATE CLI ADJ MODEL G1 GUARD& SERIES TY-FRB PENDENT SPRINKLER SHOWN SWIVEL CLIPS OVER ADJACENT BARS AND SLIDE TOWARD BASE PLATES UNTIL SNUG TFP7BO CLIP INSTALLATION TOOL SECOND / CLIP CLIP FULLY / ENGAGED CLIP INSTALLATION TOOL - •--- -CLIP -- / - APLIER MAY BE WITH INSTALLATION TOOL APPLIED OVER USED ADJACENT BARS, PRESS SECOND CLIP TOWARD BASE PLATES UNTIL FULLY ENGAGED MODEL G4 GUARD WITH MODEL S3 SHIELD & SERIES TY-L UPRIGHT SPRINKLER SHOWN components manufactured by compa- nies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products sole option. Tyco Fire Products neither as- sumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CON- TRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THE- ORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, RE- GARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LI- ABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR FIGURE 3 INSTALLATION PROCEDURE IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FIT- NESS FOR A PARTICULAR PUR- POSE. Ordering Procedure Contact your local distributor for avail- ability. Gi Sprinkler Guard: Specify: Model Gi Sprinkler Guard having a (specify) finish, P/N (specify). Red Painted ..............P/N 56-938-1-001 Zinc Chromate ............P/N 56-938-9-001 G4 Sprinkler Guard: Specify: Model G4 Sprinkler Guard having a (specify) finish, P/N (specify). Red Painted ..............P/N 56-937-1-001 Zinc Chromate ............P/N 56-937-9-001 G1/S1 Guard with Shield: Specify: Model 31/S1 Sprinkler Guard with Shield having a (specify) finish, P/N (specify). Red Painted ..............P/N 56-938-1-066 Zinc Chromate ............P/N 56-938-9-066 G4/S3 Guard with Shield: Specify: Model G4/53 Sprinkler Guard with Shield having a (specify) finish, P/N (specify). Red Painted. . ............ P/N 56-937-1-066 Zinc Chromate ............P/N 56-937-9-066 Additonal* Clip Installation Tool: Specify: Clip Installation Tool for 31 & G4 Sprinkler Guards, P/N (56-000-8-597). * The Clip Installation Tool is included with orders in original cartons. TYCO FIRE PRODUCTS, 451 North Cannon Avenue. Lansdale, Pennsylvania 19446 Sprinkler Escutcheonw401 Manufactured by: Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Product LiDescription The Central Two-Piece Adjustable Sprinkler Escutcheon is designed to enhance the appearance of pendent sprinklers when installed below ceilings. The escutcheon provides a decorative closure of the annular space between the sprinkler and the ceiling. The Two-Piece Adjustable Sprinkler Escutcheon is of a telescoping type design that provides for 2' of field adjustment, thereby assuring a good fit against the ceiling. It is available in two thread sizes and three standard finishes. Additional special finishes are available upon request which require additional ordering time and a special paint charge. Technical Data Model: 401 Style: Two-Piece Adjustable Escutcheon Size: 1/2" (12.7 mm) or Y4"(19.1 mm) N.P.T. Standard Finishes: Brass, Chrome and White Depth: Minimum: 1%" (47.6 mm) Maximum: 31/8 ' (79.4 mm) Diameter: Cup: 21/4" dia. (57.15mm) Skirt: 3W dia. '88.9 mm) Weight: 2.8 OZ. (79.4 grams) rA Installation The Two-Piece Adjustable Sprinkler Escutcheon is held in the proper position by being sandwiched be- tween the face of the reducing coupling and the wrench boss on the sprinkler. Installation Sequence: Step 3. Hand tighten the sprinkler and cup into the reducing coupling on the drop nipple. Step 4. Wrench tighten the sprinkler to the recommended torque using the proper Central Sprinkler Wrench. Step 5. After the eiling is in place, align the escutchen skirt with the sprinkler and press it up and over the escutcheon cup until the outer edge of the skirt meets the ceiling surface. Step 1. The face of the reducing coupling on the drop nipple should be a nominal 21/4 (±W) below the finished ceiling surface. Step 2. Prior to installation of the sprinkler, turn the escutcheon cup onto the sprinkler threads. Cross Section - Two-Piece Sprinkler Escutcheon - 401 fl Ordering Information Ordering Information: When placing an order, indicate the full product name. Please specify the model, size and quantity. Availability and Service: Central sprinklers, valves, accessories, and other products are available throughout the U.S. and Canada; and internationally through a network of Central Sprinkler distribution centers. You may write directly to Central Sprinkler Company or call (215) 362- 0700 for the distributor nearest you. Guarantee: Central Sprinkler Company will repair and/or replace any products found to be defective in material or workmanship within a period of one year from the date of shipment. Please refer to the current Price List for further details of the warranty. Conversion Table: 1 inch = 25.400 mm Conversions are approximate. CENTRAL _-MMMMMM11 Central Sprinkler Company 451 North cannon Avenue, Lansdale, PA 19446 © 1992 Central Sprinkler Company Phone (215) 362-0700 401.1 Printed in U.S.A. FAX (215) 362-5385 Technical Data Model: Sprinkler Head Cabinet Style: 3, 6 or 12 head Standard Finish: Red enamel Mfgr. Source: Non-domestic Capacity: 3 sprinkler heads 6 sprinkler heads 12 sprinkler heads 3, 6 & 12 Head Sprinkler Head Cabinet Dimensions: 3 head - 5" high x 7W long x 2%" deep 6 head - 5" high x 14" long x 31,4 deep 12 head -5" high x 141/4" long x 5" deep Weight: 3 head - 1.5 lbs. 6 head - 2.3 lbs. l2 head -4lbs. Sprinkler Head Cabinet Central Sprinkler Company 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 DProduct Description Central Sprinkler Head Cabinets are constructed of a metal enclosure with a hinged cover designed to provide on-site storage of an emergency supply of sprinkler heads and a sprinkler head wrench. NFPA 13 requires a representative number of each type of sprinkler head used in a sprinkler system to be stored in a cabinet on-site to allow for immediate removal and replacement of sprinklers which may have operated or become damaged. Central Sprinkler Head Cabinets are manufactured of heavy gauge steel with knock-outs to accommodate either 1/2 or %" N.P.T. threaded sprinkler heads and are painted an attractive red enamel. They are available in three (3), six (6) or twelve (12) head capacity. No. 28-6.0 PFCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 901/020 SWAY BRACE FITTING - MODEL E Part #077 SIZE - Sprinkler systems pipe: 1" thru 8" Steel Schedule 7 thru 40. SIZE - Sway brace assembly pipe: Steel 1" and 1 1/4' Schedule 40 MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTINGS Sus EX 2625 Listed only for use with other AFCON bracing products. OSHPD pending, PATENT - No. 3,570,794 FUNCTION - Per NFPA 13. Sway brace fitting of a lateral sway brace assembly. To form a 4-way, arrange adjacent lateral sway braces. INSTALLATION - Per NFPA. 13. Place Model E over pipe to be braced. Insert brace pipe through MODEL "E" under channel bracket, leaving 1" minimum extension beyond. Tighten hex nuts until gage spring lays flat or torque to 65 in-lbs. ASSEMBLY - Per NFPA 13. Combine with AFCON 70 series structure sway brace fitting and pipe brace element forming a complete sway brace. FEATURES * UL Horizontal Load Ratings for all sizes Sch. 10 thru 40 = 2015# * T.JL Horizontal Load Ratings for 1" thru 4" Sch. 7 = 655# * UL Horizontal Load Ratings for 6" Sch. 7 = I500# * Visual inspection, proper installation when gage spring lays flat. ORDERING - Part #, pipe size to be braced, brace pipe size and finish. Specific .41eC0N products are exclusively designed to be compatible ONLY with other .4PCONproducts including ports and fasteners, resulting to a listed swan brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER. AFCON will NOT warrant against the failure of its products when used in combination with otherprodstcts, parts or systems not manufactured or sold by ,4PCOPs .4 ICON shall NOT' he liable under any circumstances whatsoever for any direct or indirect, incidental or consequential dontuges of any kind, trelodung but not limited to loss of business or profit, when non-AFCONproductv have been, on are used. 11/06 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING (~) - L9, , " ~ SIZE - I and 1 1/4 inch bracing pipe. Use in combination with I thru 8 inch AFCON sway brace assemblies. MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - 203A-EX2625 Listed only for use with other AFCON bracing products. OSHPD OPA-0601 See Website. FUNCTION - Structure attachment fitting of a sway brace assembly, consisting additionally of AFCON 001 thru 040 sway brace fitting and brace element forming a complete sway brace assembly. INSTALLATION - Per NFPA- 13 . Listed for use with NFPA fastener tables. For installation on H-beam or steel web joist see AFCON 085 thru 088 sway brace adapters. ASSEMBLY - Insert brace pipe into fitting against the pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * UL Horizontal Load Rating: 2015#, All Sizes * Swivel design allows attachment at any angle. * Visual inspection, proper installation when set bolt head contacts bracket. * 17/32" Fastener hole, larger hole available.- Consult factory. ORDERING - Part //, pipe size and finish. Specific .4FCOA'praducts are exclusively designed to be compatible ONLY with other APCONpraducts including parts and fasteners, resulting in a listed sway brace, restrainer nr hanger assembly. Be advised the following wurrunty restriction will apply. DISCLAIMER- .4FCONwill NOT warrant against the failure of ins products when used in combination with other products, parts nrsystetns not inanuluetutod or sold by AFCON. AFCON shall NOT he liable tinder any circumstances whatsoever for tiny direct or indirect, incidental or consequential durnoges of any html, including but not limited to loss of business or profit, when non-AFCON products have been. or tire used. 2/07 : P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER WIDE FLANGE I I-BEAM IIIIIIIlIIIIlll SIZE RANGE - 1/2" Rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and H.D.G. LISTINGS - cus EX 2625, EX 2551 Listed only for use with other AFON bracing products. OSHPD pending, PATENT - No. 6,334,285 FUNCTION - Sway brace adapter used to attach anAFCON sway brace assembly to a wide flange or I-Beam steel structural member. To provide a point of connection when drilling is not allowed or impractical. Also can be used to attach to a steel web joist with a formed top chord. (See Drawing) INSTALLATION - Per NFPA-13. Per drawing, insert 1/2' x 1 1/4" attachment bolt into 086 bracket. Install 1/2' threaded studs thru both brackets and engage on steel flange. Assemble nuts on studs and tighten. install nuts finger tight, then additionally tighten 1/I turn or torque to 40ft. Lbs. Attach AFCOJV sway brace assembly on 1/2' bolt. On steel web joist with formed top chord install within 6" of the panel points. * 1/2" threaded studs and fasteners furnished by customer. FEATURES * UL load ratings at 30° thru 900 horizontal: Perpendicular to beam - 20154 Parallel to beam - 1265# * Universal, any flange width having thickness of 1/4" thru 1 1/4". * Studs capture head of bolt, providing hold hack. * Alternative to center loading hean'i clamp. * UL listed hanger attachment for 8" pipe. ORDERING - Part # and finish. L -5peciticAFCON products are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the follosring warranty restriction will apply. DISCLAIMER .'IFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold byAFcO's'. .4F(.'OIY shall NOT he liable under any circumstances- whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when uoaAFCON products have been, or are used. 7,06 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www.Afcon.org 410 SWAY BRACE FITTING Partdd 077-... rt# 078 SIZE - 1 thru 8 inch pipe. MATERIAL - Carbon Steel or S.S. (Type 304). FINISH - Plain, E.G., and H.D.G. LISTINGS - *us EX 2625, EX 2551 Listed only for use with other AFON bracing products. OSHPD pending. FUNCTION - Pipe attachment component of a longitudinal or 4-way sway brace, consisting additionally of AFCON 70 series attachment end, AFCON8O series adapter as required and brace pipe element forming a complete sway brace assembly. INSTALLATION - Per NFPA-13. Assemble 410 over pipe to be braced, install 70 series attachment end on outside of clamp ears and tighten bolts to minimum required torque of 40 ft.lbs. 078 is the preferred assembly component for use with the 410- see drawing. FEATURES * UL Horizontal Load Rating: 1-3 pipe size = 5004 4-8 pipe size = 2015# * Made with 1/2" bolts to conform with sway brace fittings. ORDERING - Part #, pipe size and finish. Speeifte.4FCON products am exclusively designed to be compatible ONLY with atlterAFCOf' prod utn including parts and fasteners. resulting ma hated sway brace, restrainer or hunger assembly. Be advised the following warranty restriction will apply. O1SCLAMEI1 - .4FCON will NOT warrant against tite failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFcON. A ICON shall NOT he liable under any circumstances whatsoever fur any direct or indirect, incidental or consequential dannages of any kind, including but not hunted to loss of business or profit, when non-AFCON products have been, nr are used, 9/06 Size Range - Secures 3/8' thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Size Range - Secures 3/8 thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. IT Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 -All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750'F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1/2 - 11630 10370 510 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92879 • Ph 951.737.5599 • Fax; 951.7370330 Customer Service • 800.786.5266 www.toko.com Fig. 200 — "Trim line" Adjustable Band Hanger Size Range - 1/2' thru 8' pipe Material - Carbon Steel, Mil. Galvanized to G90 specifications Function - For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (272" thru 8' Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals - Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CFVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Maximum Temperature - 650° F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOTM Fig. 200 WON. Order By - Figure number and pipe size Dimensions • Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm 3'IB 2f,/e 400 11 3/4 3/8 8mm or 10mm 31/8 2'/2 400 11 1 3/8 8mm or 10mm 33/,, 25/,, 400 12 11/4 3/8 8mm or 10mm 33/4 2/,, 400 13 1'/2 3/8 8mm or 10mm 3/,, 2/,, 400 14 2 3/8 8mm or 10mm 41I2 3 400 15 2'/2 3/8 10mm 5/,, 4/B 600 - 27 3 3/8 10mm 5/,, 4 600 29 31/2 3/8 10mm 73/,, 51/4 600 34 4 3/8 10mm 73/,, 5 1000 35 5 1/2 12mm 9V,, 6'14 1250 66 6 1/2 12mm 101/,, 53/4 1250 73 8 1/2 12mm 13'18 8I., 1250 136 Office/Manufacturing Facility • 1375 Sampson Ave. • Corona, CA 92079 • Ph: 951.737.5599 • Fax; 951.737.0330 I Customer Service • 800.786.5266 www.tolco.com 4.38 HDI & HD-L Drop-In Anchor 43.8.1 Product Description 4.3E1.2 Mt4IDE C)fli * Ti),I HDiLIDrcr ao a • I-a xoanoaar' 4.o 3 1dcnicl 4 8 4 hoi or r Product Features . Guide Specif ications HDI . Expansion Anchor ETaa', a. a t'C'a'a .If:n tool ama I a rnalche4 to:ranco sosiom AS:M O(' T La' IF a: La 0 Ha' Li0a a :aco en :1q'coaa —'4 ''r-' U -41 03' Installation a P : '-s 1 : F od _r c Lp r)'aa., flcr' 't fl SCOIO. 0. a0ttt of 00 0 (OntO taeal for pUt rUe 'ast'i a, 'h \I.tt ''eadec as o1 eaad LrtF . 4.38.2 Material Specifications }IDlHDlL,I- '8 IanHi):3 a .470 ,mr ac"n ca'ba" steel 'oioh s rtiateri 'a. 1n1 a n:oc ''tat' o •- . aoorutt000 14 ""ST I'* B t72o .3,.1 T" F",. Ili H ' t' L Li ICC-ES (International Code Council) L'B-20)a HDI ( COLA (City of Los Angeles) 4.3.8.3 Technical Data . 1-105030.. 'a 000C Na,, 31_73t 13.4 FM (Factory Mutual HDIIHDNL Specification Table HOPHDI-L HDI . . Poa'a Haai:oo Co'npc"s::a ta: .4,,, uOo' kln ":ta'-n a F 0 UL (Und' rs arriteLabratoncs) 4:. 723 Pta H'ann For. can.10 2-1.410 7 15 oF 10 Y' : a 211 10 13 11 10 I' ''tNt in F o-ia I " - 4-It I 22 77 50 Combined Shear and TLnsion Loadinu ttt/ ,L t.''Li',,4' Anchor S h- 2000 psi 13M 40O psi (278MPO 1 6000 psi 4 1 itPa) TensIon lb ikb Shear lb l Tension lb kl Shear lb . Tension lb 0 She3r lb 1101 HDl-L KOI 801-S 801 1101 L HOt 1401-L 1101 i 801-S 1101 HOt S 1/ 50i 4 59i 025 - Ii 17'. l2' 1 29 3 15 4'3 - .9 .. Carbon Steel HDl Ultimate Loads in Concrete Carbon Steel HDI Allowabie Loads in Lightweight Concrete and Lightweight Concrete over Met-it Deck', nniioIn. tnita in b 2 pn . 1 ftfl500l Instried lhrouqh St el Dour lip r Hu1 9rir11r 1: 6 ihrniqi Oil Deck Lmr HO 5iz LI i/I C cro Into aooa psi '-. Li VIL Car rain' lobi AI DO a '1 01 .51 (-an ntr 1 Thnscin. lb 90cr. Thn ion WI-. mi lb 0 La .0 0 0 174 mo -1 465 . 340 j 530 01 335 370 250 3/8 1 040 1 r 55fl 1010 500 — 1/211 9135 1 1700 1105 .1 1705 Ii2 ii 5/8 0 1465 283:i - 07 m 2075 - 1 l0U0' L a 101 ll -OlI6o + Stainless Steel HOt Allowable Loads in Concrete Anchpr sIze 4000 psi 'N0 MIF 6NO psi.: I 1111) Tension lb 'kSi Shear in IrS Tension lb S. Shear lb S' 53801 l -9 480 600 -1 711 740 ' 500 ml [ $880:- 2/6 . - 1040 1- 1230 . 1460 1230. OS Hl — 12 i Li 7/ SS 1101- iSo - 19-40 2760 I 2630 4510 2410 1770 2710 4510 SS8Ui-3 I 1. - a830 5580 5030 4 SaSO 1. Stainlcs Steel HO! IJitiniato LozWs in Concrete ------ Anchor size, 4000 pi 1 1 i 11)1) • Sm -Li 11 I lension lb Shear Ii I . mimi ii lb .60 ar Ii 00-101 1 I • -i 1930 2400 11 2O%) 2400 08 1101 - 3 -0t 5950 4,320 i900 Eli - 02 00 SSHDl5h (Lit I 73 5 0 7 10040 -' - 11040 491 181)40 hlIL/ 5630 15100 11040 18040 88801-34 00 0 J 15340 - 2232009.4, J 20130 •.. 22120 -- H.. - aOl - 4ci - oJ_. _..+.+.,. a. •. tn - I ,,,+) - :.mf." 5-',- - Lr kw.ik .Boit 3 Expansion Anchor 4.3.5.1 Product Descri ption r (KH3ts a Product Featutes .3 3 emanyor vcro, Much • L.: (ifl . f .3Ur0 . ar a rer: r0c00 a — .. : on win. rrr --ft ira an iri3' ft 3 3Eibft ti rtd enQars arcirci e:tron :ac cowny camon V% vM. V3HJC5 117 and rican YvAct SOC SC •. t1p rlvc ;rri cria3na 333 aJ-rui; - 3a05 C. nwmns . RaIsed r pr- c-ito :b.zrd daan2 I . . vors-an: Tb tn'rc.o -nci ftcancraris,abn c';--: . A ;- in ii' I L size iro ci ac -ritcr: cr a ci Nam C -a 1. for am, -. a2o -c -cl., -cit. iaOh r____ '- . 3 C- r-> 3flH liE ri jr- . t'a Ailci ccir race r-li'U U j nn"C (Ic; Ca Iliies af ter cC2C norms ric cmi, slruc..trit • C(II U'S '.Oci (ion hrmad El-- iimfI1C'ii (IC'- dr'J Iroi;; installation Guide Specifications I . . •.tv,- -j1 CMWEW. or WOW Tau I . Tcmciu a antr -'ci " n"nson r-ccio- a aria a'- ano ,r , cg a HM CW2 cia MWe Kwk Haci .3 supynJ ci t card a -2 a, cii. or. I''i we a-macig"I M wwwal WMANTIMT1ci W 09 1mar-. 3)-macc'— rica 2-A 1E2%3, 3c Icr-ri ''o-ci . ic ;-' ç 00 ioarr. ri Any ,iJSl't color Vanwo" to U II cr-n cc a 'a rI 3oi 3 a Me mamma 'C ' 3- ci 3 1, -ii a -on locH on rm_' -ima cam ifma'r-rerl ma r--,ai -mac' ci-: arc anm;ma Ttm at rr- 'cmi to in can:; 13'i; ICC <iEl'CcHI 00i)rma Li 0 :-t:.,- 'a Ltstcnpprovals - . .. ICC ES (international Code Council)r I EAT1385 Sc-mr calic reoccimmau a mar- 0 0 H/,. P (.0 33 3cr-ma rcoc:) cii a ,- anmani norifyinagn: Hr -I City of Los Angeles (CG) AS VA b 6.3 to a acm ama. II 0 Como" DWQ be Waml - ,. Uncm'avrr-aa Lnrcior-c nen no : ym . . . UL (Undeinters Laboratories) . . . - UL 203 Pioe Hanger Equpman for ci c- alma. Ic-diP rum- ';~reads I ml we Now 'cie solam if arc Services 3 - by, me hyne, TqlPn We iN to Ou Factory Mutual (FM) ownnnr curfTo,'r- - ii I ci 0 'Orns to 1 Mo;ro-Dade County 1 no ft rio ma, 001'C ' 1 anhy tom ar.. - 'cm'- - . ma Al"-'I 30i TIir. ci ............ c'a-'.-.e C=0mr-' a AVA a oc.ama........... Miii, Fracture 1 Anchor Diameter (in? Load (Ib 173 kwik Bolt 3 Expansion Anchor 4.35 4..35.2 Material Specifications Carbon steel with electroplated zinc $ftCcvr o Steel wi Bohr, Lc" TI BA,? 3Cr: Ron Couoi,rcl A: :on exj,iu di 3r .. ri 1 r,r: or- Id 'nrA r.r'd -ii'. At i'i Ion x 1' O'U 1 and .,.' ii" . hr.'., ' 0c3t c' AS1 7? 3? to m r mun thir ''nm : i:uc,nic'm 131 n 'V4iir 'u r.m' 3331 A IA', A' n.y- Ht Va" m'rn C-rUnt t'ur ro C"'flt C I Itt? Expansic;i,,, -c.'s '.',d,in rFr' 'i'ano c',r'c.I ft. 'n 't)of sloe. ocen: I ''t-Ila,m inclnter. ''r 'A 1'? "nh da'r'r 3 C-bC-re 37 I ii'" d'emerc 'u . * Al i VOL.1 V"SUUk B VI V Carbon steel with hot-dip galvanized coating o3s iri'ir tIC-IC C r:.nn rmoi "nm' "e ruin' nmi rim n 10Cr volt 153 Cuss C 143 m 'u-n AL V -' Iv CiL' Alr fl rA31 A Ut A to t r:ulre --ft' e' ASI di 1'1 1. ' .pr-r,. ii' '. dnn'trin''nqC-tl :,r'. rr:utciv'; Li 10:0 eta, flu Stainless steel . . . --"- - Anchor Mm, Fractme Dot tie.) Load rain, lIlt' '-n-B $oit iciort. ,n- oci,,:'i-J 'rot $17' 343 0'?'-: 510 'r,enohiom t?t:'.512171$.13'c.3'hm.'oel- . S Anchor Mm. Tensile Mn Yield Nuts m.ee; Diameter (in.) Strength tksi) Strengin )ko 'Si'n- 'ucot 1t' d-tn't ro lnmilo'uu cC- .- NA 13' -- S <pu'.uo;- .31ee.0 Icr 1131 :3.1 3 4 5'' 01' .. 11" ii' 'dii' •" "I 'ii 43. '7 lyle 30', C-dir ft IC-C ?,IO"tO3 Ii' T 1 COil' CIL'rrlilC'fl $131 '- 4 tt"t 313 IACttrft': I A Combined Shear and Tension Loading '4 LI I I m',- [D WIS Bolt Size in 1/4 . 4 3ti 1/i in 4 drpth . in 1-IM 2 3 1-5/8 2 1.2 3 1!2 2-1/4 3112 4-3,14 - I 1111 13/8 21/4, 31/4 2 27b 37/8 2314 1 51/4 C,irt'Sn. ft lb 4 20 40 Fl ,:" . . ft 0 6 20 411 ( I ft-lb 4 15 25 ------------ Min, b Details Bolt Size in dim ,Jrfl,,H m" it 34 t in 2 '1/4 4 5'1/ .3 4 4 3/it 1.1 4 1 !22 /1 0 i3 458 8 1/5 4 3-12 34/5 51f2 ' 7 16 Ij 114b 83 180 230 'I /t lb 83 i0 23,t ft lb Sb 120 - . F Kwik Bolt 3Expansi on Anchor 4.35 TabLe 2 Carbon Steê<wik Bolt 3 Allowable Loads in Norm -31-Weight Concrete AnOor Fmbedmen 2000 ps - 000 0 ps Diameter DPt1 1nsior Soon Jn u Sneir inion Sfieor Ton 0. I0.', Ib Ib5 300 363 430 550 1) 2 f 34': 755 795 /50 1155 910 1//Y 109 02t 100J 1 513 * 1 16:5 2 0 f 14 W 1437 1480 51"' 1530 1773 i95 21 5~1 I . • 1253 1043 1435 2310 11120 5735 1375 1/2 1930 ?lc8 3245 LOSo 31/2 3020W 332n 21 5. 3021 43/ 27802035 .3416 :s1fj 4970 2830 56 2960 3029 3398 4773 4896 • .. 4355' 5+ 48n5 '0866 + 32136 3092 1100 532o • 2175 4034 2125 43) 4753 071 721 0715 . I 314 • 5241 4200 . 520 6155 732n • * * 835 SOnO .185 7004 • .0 4030 7501j 457518140 8071 I 4133, * 9 53 71i7 134 7673 3370 0 1060 ,,-. . I OL :1. * . * ,•. . * * ** 4•35Kwik Bolt 3 Expansion Anchor Tabie 8 Carbon Steel Kwik Bolt 3 Allowoble Loads in Lightweight Coiicrct& Anchor 5nor Tristan Tension fcrfllon sar' Diameter U.sth f_2C0ps '))'. j 30C.0 psi 'P j 1iO0 .' e-.2DOO psi .14 :11/ :' 275 22 ' 400 * 2 95 i"O Th.. 45fl 318 154 ' 585 75 1° .l 1120 111 1.0 1160 152. 1754 1010 20 0 2260 26351. I 519 7 2-54 1560 18)s 2070 - 25ri0 2465 . 317.1 5' 5560 3/4 3-i'4 ' 620'. 22.0'. ' 25601 3635 o 141 Table 9 Stainless Steel Kwlk Bolt 3 Allowable Loads in Lightweight Concrete ,,3 Acibe Teflso'i Depth f-20O[)psi MH 3Cs0 nsi . Ii 'ifl'lt . 4. -. lb 10 ,', 356 045 2 510 1363 625 9' 1205'475 1345 12 2-1/4 01 950 ' 1155 3364 1350 . 535)i 5955' 147, ' 1r1"0 • , 1711 , 4 S ' 2390' , 2715 ' 513 ' . ' . ,, . . •,. . . . . . ..;. Thhle 10- Carbon Steel Kwik Bolt 3 Allowable Loads for anchor . installed at 1-3/4 in, Edge Distance in Normai-Weight Concrete . . I , J> 2000 psi' IAnctiv tOn Oei4 545,11 ' Oiiiclnr I Enbdmat . Tnslsn I>crpoiilicuinr Pr:aJti . . . lb ' Vj ['Ons In 0545 3, 93- 2 ' 1130 ' ' 500 4.7 't - ' 4555, S •'. b. . . . POT 'r'E D I J VANE TYPE WATERF'LOW The Symbol of Protection ALARM SWITCH WITH RETARD ... =.==_ .. . UL, ULC and CSFN'i Listed, FM and LPCBApprovcd, NYM.EA Accepted, CE Marked °. ... Service Pressure: Up to 450 PSI (31 BAR) Minimum Flow Rate forAlarm: 10 GPM (38 LPM) U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric. Rd., 1990 GENERA!.. INFORMATION The Model VSR-F is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8° (50mm thru 200mm). I.PC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also he used as a sectional waterfiow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. Maximum Surge: 18 FPS (5,5 m/s) Contact Ratings: Two sets ofSP.DI (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30 VDC Resistive Conduit Entrances: Two knockouts provided for 1/2 conduit Environmental Specifications: Suitable for indoor or outdoor use with lactory installed gasket and die-cast housing. NEMA 4/IP54 Rated Enclosure - use with appropriate conduit Fitting. Temperature Range: 40°F/120°F, 4,5°C/49°C Non-connsive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. SizesAvailable.: Steel Pipe schedules 10 thru 40, sizes 2° thru 8° BS 1387 pipe 50mm thru200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One ortwo family dwelling NFPA-13 D Residential occupancy up to four stories NI-'PA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 LNs1ALLvr1ON: See Fig.2 These devices may he mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of I 1/4" + 1/8" - 1/16" (33mm ±2mm). All other sizes require a hole with a diameter of 2" ±1/8" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (68 n-m) of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. - Potter Electric Signal Company . 2081 Craig Road, St. Louis, MO. 63146.4161 • Phone: 800-325-3936/Canada 888-882.1833 • www.pottersignal.com .....- ................. n PRINTED IN USA MKT. #8800001 - REV W PAGE) OF 2 MFG. #54007t1 . 7/02 IS POTTER - The Symbol of Protection FIG.,! FJG.2 SWITCH TERMINAL 1 VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD = CONNECTIONS OPTIONAL TAMPER SWITCH CLAMPING PLATE TERMINAL RETARD ADJUSTMENT: IU I.IIANUL TIME TURN (NOD (t.IIht.fS DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS, A 'B' SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY IS SET TO DO NOT LEAVE COVER OFF FOR EXTENDED PERIOD OF TIME TIGHTEN NUTS ALTERNATELY 10 AN EVENTUAL SOFT-LBS (68 n-M) OF TORQUE owns 911.i CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. TEl kiOrni I flPII I .inI R /,0 ,klr,rroTrn. PIPE SIZE HOLE SIZE to 2 1/2" 1 1/4" +1/8' -1/16" (50mm 10 65mm) (33mm ±2mm) to 8" 2" ±1/8" (80mm to 200mm) 50mm ±2mm) Cover Tamper (with cover in place) ~Tj DIRECTION OF WATERFLOW (EXT) RED (BiLl DWG. #761 -30 MOUNT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) o o A 10-25 6 20-40 C 35-55 0 50-70 t 60-90 FIG. 3 TYPICAL ELECTRICAL CONNECTIONS S srrs OF .NOIU,IALLY OPEN CONTACTS WATF.P.FLOW ZONE. ROLl FROM CLOSE ON ALARM ON FIRE PANEl. FIRE PANEl.. TI IX N.C. AND NO. MARKINGS ON POSITIVE DC TIIESWITCtIAREFOSANALARM ORIIOTAC CONDITION. BELL NtiIJATIVIi DC OR TIlE CONTACTS ARE REVERSED NEC (RAL AC WHEN THE DEVICE IS IN THE NORMAL CONDITION, tIWoSI( NOTES: The Model VSR-F has two switches, one can be used to operate a central station, proprietary or remote signaling unit, while the other contact is used to operate a local audible or visual annunciator. A condition of Ll'C Approval of this product is that the electrical entry must be sealed to exclude moisture. For supervised circuits see "Switch Terminal Connections" drawing and caution note (Fig. I). FIG. 4 To remove knockouts: Place screwdriver at edge of knockouts. not in the center. M. 1761-4 APPLICATION WARNING! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initialing device to discharge AFFF, deluge, or chemical suppression systems, TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions fbr testing the operation of the flow detection device on the system. application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm (38 Lpm) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must he tested ill accordance with the testing instructions. - - " - PRINTED IN USA MKT. #8800001 - REV W PAGE 2 01`2 MFG. 45400761 - 7/02 Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 660C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. SIZE INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENT (MAX) TYPICAL dB ATIOFT. (3m) (2) MINIMUM dB ATIOFT. (3m) )1) 6(150) 12VDC PB0126 1706012 .12A 85 76 8(200) 12VDC PBD128 1708012 12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6 (150) 24VDC PBD246 1706024 .06A 87 76 8 (200) 24VDC PB0248 1708024 .06A 91 79 10(250) 24VDC PBD2410 1710024 .06A 94 79 6 (150) 24VAC PBA246 1806024 17A 91 - 76 8(200) 24VAC P8A248 1808024 .17A 94 76 10 (250) 24VAC PBA24I0 1810024 17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10 (250) I20VAC PBAI2010 1810120 USA 99 85 P0 rTgz 'Z The Symbol of Protection 2EV PBA-AC & PBD-DC UL Listed, FM Approved Sizes Available: 6(150mm), 8(200mm) and 10" (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2t0 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurgiarAlarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Potter Electric Signal Company 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 www.pottersignal.Com PRINTED IN USA MKT. #8850001 - REV 0 PAGE 1 OF 2 MFG. #5400776- 12/01 BELLS 11J OT TER PBA-AC & PBD-DC The Symbol of Protection DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOF BACKBOX BOX HAS ONETHREADED 1/2 CONDUIT ENTRANCE - 10" " C)(250) 5 3/4 (146) (20 _J 15 0) (41) 2 11/16" DING. #776-1 (68) - Ob) 4 1/4" (108) DWG. #776-2 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS RED (OUT) WHITE (IN) WHITE (OUT) RED (IN) CGLIACK FROM CONTROL PANEL C.LACK -LINE OR OR ELL FROM CONTROL PANEL R PRECEDING BE PRECEDING BELL BLACIC (IN) _ CAUTION WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN NOTES: OBSERVE POLARITY TO RING D.C. BELLS, RED WIRES POSITIVE (+) BLACK WIRES NEGATIVE (-) CAUTION' WHEN ELECTRICAL SUPERVISION IS REOUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: I. WHEN USING A.C. BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2, END-OF-LINE RESISTOR IS NOT REQUIRED ON AC. BELLS, DWG. #776-3 INSTALLATION The bell should be mounted a minimum of 8 ft. (2,4m) from the floor or as close to the ceiling as possible. Removethegong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PRINTED IN USA MKT. #8850001- REV Q PAGE 2OF2 MFG. #5400776 - 12101 Asc&m-:~ Table of Contents OVERHEAD PIPE & FITTINGS TRI-CITY MEDICAL OFFICE BUILDING T.I. DynamThread 0 Full Line Sch-40 Replacement Dyna Threada offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for lire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (R <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Seh-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF". In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Mierobiologically Influenced corrosion (MTC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyha-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (1120 Filled) Pcs/ WI/Lift (21) WI/lift (24) WI/Lift (25) In; mm In; mm Lbs/Ft; Kg/rn Lbs/Ft; Kg/rn Lift Lb.s; Kg Lbs; Kg Lbs; Kg 1" 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 114 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 114 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2' 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 k 16100 S. Lathrop • Harvey, IL 60426 Customer Service: NCO n-T- dhed 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3 -3 Threaded Fittings Tyco Fire Products --- www.tyco-grooved.com EENTRAL 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA _______ Customer Service/Sales: Tel: (215) 362-0700 / Fax: (215) 362-5385 Grooved Piping Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 General Description (uJji" See Fire Protection Submittal sheet for pressure rating and Listing and Approval information Ductile Iron threaded fittings (with the exception of California Tees and Street Elbows) conform to ANSI B16.3. They are higher in strength and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties making up the fitting. This is accomplished by adding magnesium while the iron is being poured into it final cast shape. This provides an advantage-as the fittings are not as susceptible to leaks or cracking and they are also lighter than standard cast iron. Caution: Installers who have not used ductile iron threaded fittings before should be instructed that the fittings are stronger than the pipe and over- tightening the fitting can create leaks and cause damage to pipe threads. in general, there is about one-half turn difference between cast iron and ductile iron fittings. Apply Teflon tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If you are using an automatic make-on machine, please exercise caution in setting your machine to the proper parameters prior to tightening fittings onto the male pipe threads. Technical Data Figures: 811, 812, 813, 814, 815, 816, 817, 818, 820, 825, 827, 830, 719, California Tees, and Street Elbows Sizes: 1/2 - 21/2 ' Maximum Working Pressure: 800 Series, California Tees, and Street Elbows: 300 psi Figure 719: 250 psi Approvals: UL, and FM Note: See Fire Protection Submittal Sheet for exact Listing/Approval information. Manufacture Source: Imported Material: Ductile Iron, conforming to ANSI B16.3 (Note: Figure 719 Plugs are constructed of Cast Iron) Thread: N.P.T. r3 Installation Apply Teflon Tape or high quality pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. (See caution in first column) fl Ordering Procedure Ordering information: When placing an order, indicate the full product name. Please specify the quantity, figure number and size. Availability and Service: Grooved Piping Products, valves, accessories and other products are available throughout the U.S., Canada, and internationally, though a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. No. 21-3.0 Size Inches A Inches B Inches Part Number Weight Lbs. Box Sty. 1/2 11/8 '/16 86206 0.24 240 3/4 1I1 3/4 86205 0.40 120 1 11/2 13/16 86200 0.64 70 11/4 l/4 11/16 86201 0.95 40 11/2 116/16 l/,6 86202 1.24 30 2 21/4 11/2 86203 1.74 20 21/2 211/16 i/16 86204 3.28 10 Figure 81 5 -2- Figure 811 90' Elbow F A- Size Inches A Inches B Inches C Inches S Inches E Inches F Inches Part Number Wt. Lbs. I Box Sty. 3/4 X 3/4 X 1/2 1/16 1/16 11/4 /6 /8 11/16 86235 0.46 95 3/4 x 3I4X1 1/16 17/16 1/8 7/ 7/ 11/16 86755 0.68 65 1 x 1/2 xi 1V2 1/8 11/2 13/16 i3/16 13/75 86236 0.70 55 1X 3/4x 1/2 11/4 1/i6 1I8 /1e /8 13/16 86756 0.63 80 1 x 3/4 X 1/8 1/16 1/16 11/16 3/4 I8 86757 0.68 65 1 x 3/4 x 1 11/2 i'/is 11/2 13/1 I8 23/16 86237 0.77 55 lxi X112 1/4 11/4 1/ /16 9/16 13/16 86238 0.66 65 1x1x 3/4 la/a i/ 1/16 11/74 11/16 7/ 86239 0.73 60 1 X x 11/4 111/16 1 /16 1/i6 1 1 7J8 86240 0.97 45 1 X x 11/2 113/16 113/16 1/8 11/8 11/8 /8 86241 1.14 35 11/4 X x 1/2 115/16 11/4 1/i6 /8 9/16 1 86242 0.81 50 11/4 X1X 3/4 17/16 118 l/8 3/4 11/76 11/16 86243 0.901 50 11/4 X 1 xi 19/16 11/2 121/16 /6 13/16 1 86244 1.03 45 11/4 x1 X11/4 1/4 171/16 1/4 11/16 1 11/16 86245 1.10 40 11/4 X1 XlV2 1/6 113/16 113/16 is/is V/a 11/16 86246 1.43 30 11/4x 12/4X1/2 1/8 la/s 1/16 11/16 °/is 1 86247 0.87 45 11/4x11/4X3/1 li/is 17/ 16 i/8 3/4 3/4 11/16 86248 0.96 45 1114X1V4X1 19/16 i/16 111/16 7/ /8 1 86249 1.10 40 11/4X 174X 11/2 1/8 11/8 113/16 1 3/16 113/16 11/16 86250 1.50 30 11/4X 11/4 X2 21/6 21/6 2 17/16 1 /1 11/3 86251 2.00 24 11/2 x 1 XV2 17/ 16 1/i6 lU/is 11/16 /8 11/8 86252 0.97 40 11/2 x 1 X 3/4 11/2 1/8 l/4 3/4 11/16 1 13/ 16 86253 1.14 40 11/2 x 1 xi i/8 11/2 113/16 /8 13/16 V/a 86254 1 .14 30 11/2X1X11/2 115/16 113/16 1 5/16 la/is 1 /6 13/16 86255 1.52 30 11/2 xl 1/4 x 1/2 17/16 1 /16 111/16 11/16 5/ 11/3 86257 1.03 40 11/2X11/4X3/4 11/2 1/16 1/4 3/4 3/4 1/16 86258 1.10 40 11/2X 11/4x 1 1/8 1/16 113/16 /8 7/ 11/8 86259 1.31 30 11/2X 11/4x2 2/16 21/8 2 17/16 17/16 11/4 86260 1.94 20 11/2X 1'/2X'/2 1/i6 1/16 11'/16 11/16 11/16 11/8 86261 1 .141 35 11/2X1V2X3/4 11/2 11/2 1/4 3/4 3/4 is/is 86262 1.23 35 11/2x11/2x1 is/s la/s 113/16 7/ /8 V/a 86263 1.38 30 11/2 X 11/2x 11/4 113/16 113/16 1/8 11/16 11/16 13/ 16 86264 1.50 30 11/2X11/2x2 2/is 2 /16 2 17/ 16 17/16 11/4 86265 2.00 20 2x 1 x2 2V4 2 21/4 11/2 1a/16 11/2 86266 2.18 15 2 xi 1/4 x2 21/4 21/8 21/4 11/2 17 /16 11/2 86267 2.31 15 2 x11/2 X 1/2 11/2 17/16 V/a 3/4 11/16 1 s/i6 86268 1.50 30 2x 11/2 x3/4 1/8 11/2 115/16 7/ 3/4 la /a 86269 1.61 25 2 xl 1/2 X 1/4 1 '/B 2 1 7/ V/16 86270 1.65 20 2x 11/2x 11/2 21/16 111/16 2/16 i s/is 1 /s 17/ 16 86272 2.03 20 2 xi 1/2x2 21/4 2/16 21/4 11/2 17/16 11/2 86273 2.37 15 2X202 11/2 11/2 1i/8 3/4 3/4 15/i6 86222 1.50 30 2X2X3/4 is/a 11/8115/16 7/8 /8 13 86223 1.67 20 2 x 2 xl 1/4 1/4 2 1 1 1/i6 86224 1.91 20 2 x 2 x 11/4 17/8 1/6 21/6 11/8 11/6 1 '/16 86225 2.05 20 2x2x11/2 2 2 2/16 1 '/4 11/4 11/2 86226 2.11 15 2 x 2 x 21/2 2/a 2/6 2/8 1/4 17/, 17/,,i J86227 3.671 10 21/2 x 2 x 3/4 1/4 1/ 2/16 /8 7/s 1/4 186274 2.22 15 F7 Figure 1 900 Reducing Elbow Size Inches A Inches B Inches C Inches 0 Inches Part Number Weight Lbs. Box Sty. 3/4 x 1/2 1/1e l/i I8 5/ 86342 0.33 160 1 X 1/2 11/4 1/a 9/16 13/16 86210 0.44 110 1 x 3/4 1I8 1/16 11/16 7/ 86211 0.53 90 12/4 X 1/2 1/i6 11/2 /8 15/16 86212 0.64 75 11/4 X 3/4 1/16 1/8 3/4 11/16 86213 0.75 60 11/4 X 1/16 111/16 /8 1 86214 0.77 55 11/2 x 3/4 1 /2 1/4 3/4 1/s 86221 0.95 45 11/2 X1 1/8 113/16 7/3 11/8 86215 0.99 40 11/2 X 11/4 113/16 1/8 11/8 86216 1.14 35 2 x 3/4 1I8 115/16 7/ 1/8 86217 1.39 30 2 x 1 1/4 21/16 2 1I16 86218 1.58 25 2 x 11/2 2 2/i6 1V4 1 /16 86220 1.67 20 21/2 x 2 2/8 2/8 11/4 1/8 86262 3.01 15 Size Inches A Inches B Inches Part Number Weight Lbs. Box Sty. 1/2 7/ 3/ 86780 0.22 250 3/4 1 /i6 86781 0.33 150 1 1 11/8 13/16 86280 0.48 90 11/4 1/is /8 86281 0.73 50 11/2 1/16 11/16 86282 0.93 35 2 111/16 15/16 86283 1.55 18 2/2 115/i6 1 86782 2.70 12 Size Inches A Inches B Inches Part Number Weight Lbs, Box Sty. 1/2 11/8 /16 86340 0.33 150 3/4 15l16 3/4 86341 0.50 90 1 11/2 13/16 86230 0.85 60 11/4 1/4 11/16 86231 1.30 35 11/2 125/16 13/ 16 86232 1.63 24 2 21/4 11/2 86233 2.63 12 21/2 211/16 1/1s 86234 4.55 8 Figure 813 450 Elbow Figure 814 Tee Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 1/ 72776 0.15 500 3/4 1 72777 0.22 300 1 1/16 72824 0.33 180 11/4 1/16 72756 0.54 110 11/2 1/s 72822 0.68 80 2 11/2 72823 0.96 45 21/2 1/4 72825 1.80 25 Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 15/16 86292 0.10 500 3/4 11/a 86293 0.18 300 1 11/4 86294 0.28 200 11/4 1/s 86295 0.50 110 1V2 1/l6 86296 0.70 80 2 11/2 86297 0.90 1 45 Figure 820 Cap r A Figure 719 Cast Iron Plug Size Inches A inches B Inches Part Number Weight Lbs. Box Oty. 3/4 x V2 l/4 11/16 86772 0.38 240 1 x 1/2 1uh/16 1/2 86228 0.38 200 1 X 3/4 114 1/2 86229 0.53 110 Figure 825 Extension Piece Size Inches A Inches Part Number Weight Lbs. Box Oty. 1/2 x 11/2 11/2 72751 0.20 300 1/2 X2 2 72980 0.27 250 3/4X 11/2 11/2 72981 0.22 250 3/4 x 2 2 72982 0.31 200 Figure 816 Reducing Coupling ri Figure 817 Cross Figure 827 Hex Bushing Size Inches A inches B Inches C Inches D Inches Part Number Weight Lbs. Box Oty. 1 11/2 11/2 13/16 13/16 86284 0.97 45 11/4 1/4 1/4 11/16 11/16 86285 1.59 25 11/2 115/16 115/16 1/1 1/16 86286 1.89 20 2 21/4 21/4 11/2 11/2 86287 2.93 10 11/4 x 11/4 x 1 x 1 111/16 19/16 1 /s 86289 1.25 30 11/2 X 11/2X 1 X 1 113/16 V/8 11/16 115/16 86322 1.48 24 2 x 2 x x 1 2 1/4 11/4 11/16 86291 2.64 10 Size Inches A Inches Part Number Weight Lbs. Box Oty. 1 x 1/2 11/16 72726 0.22 280 1 x 3/4 11/is 72762 0.18 280 11/4 X 1/1e 72763 0.31 150 11/2 x 1 11/4 72757 0.53 100 11/2X11/4 11/4 72764 0.35 100 2 x 1 13 /a 72759 0.75 80 2x 11/4 1/ 72761 0.69 80 -Tx 11/2 1 ~A 72775 0.62 80 Figure 818 B A Straight Coupling til Size Inches A Inches B Inches Part Number Wrench Weight Lbs. Box Oty. 1/2 V/8 IA6 72779 11/6 0.18 360 3/4 1/a /16 72778 1/s 0.26 200 1 1/4 3/ 72755 111/16 0.44 110 11/4 2 s/16 72754 2 0.54 75 11/2 2/16 3/ 72753 21/4 0.71 60 2 2/8 11/6 72752 2/a 1.15 30 21/2 3 3/4 72758 33/s 2.29 18 L11i Figure 830 [ I 1 A Brass Seat Union Li Size Inches A Inches B Inches Part Number Weight Lbs. Box Oty. 1/2 1/8 13/16 86207 0.47 110 3/ 2 15/16 86275 0.66 80 1 2/16 13/16 86276 1.08 50 11/4 21/2 11/16 86277 1.54 35 11/2 2/a 1/1 86278 2.03 25 2 31/8 1/ 86279 3.15 18 -3- Street Elbows Size Inches A Inches B Inches C Inches Part Number Weight lbs. Box Oty. 1 X 1/2 11/2 3/4 3 42003 0.70 80 1 X 1 11/2 3/4 3 42002 0.90 60 -q ----L4 California Tees LL Size Inches A Inches B Inches C Inches 0 Inches Part Number Weight lbs. Box Qty. 1 X 1/2 X 1 11/2 /8 3 3/4 42000 0.95 50 1 x 1 x 1 11/2 3/4 3 1 3/4 42001 0.95 45 I Limited Wanly Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by Tyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products or for products and components which have been subject to misuse, improper installation, corrosion or which have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire Products shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Never remove any piping component nor correct or modify ani piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. tqco/F/ow Control/ Tyco Fire Products Printed U.S A. 10-01 tLICL7. Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap General Description U L See Fire Protection Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Figure 40-5 Strap isan economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet, dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type III Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1 895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, type of gasket, Grade "E" EPDM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of the National Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment byTyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Productsorfor products and components which have been subject to misuse, improper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products' sole option. Tyco Fire Products neither assumes, nor authorizes any person to assumeforit, any other obligation in connectionwith the sale of products or parts of products. Tyco Fire Productsshall notbe responsible for spnnklersystem design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BLITNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHERTYCO FIRE PRODUCTSWAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALLTYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS MADE IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Page 1 of 2 September 2004 TFPI720 Pipe Nominal Dimensions Hole Net Size Size Wt. A B C D Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg- 1 '/4 x /0 2.00 1.50 3.50 1.20 1/16 0.84 50.8 38.1 88.9 30.5 30.2 0.4 11/4 X 3/0 2.00 1.50 3.50 1.20 13A6 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4 X V 2.31 1.68 3.50 1.20 13A6 1.13 58.7 42.7 88.9 30.5 30.2 0.5 11/2 x 1/20 2.12 1.62 3.50 1.32 13As 0.84 53.8 41.1 88.9 33.5 30.2 0.4 11/2 3/0 2.12 1.62 3.50 1.32 13A6 0.88 53.8 41.1 88.9 33.5 30.2 0.4 2.43 1.80 3.50 1.32 1/16 1.13 61.7 45.7 88.9 33.5 30.2 0.5 2" x 1/20 2.36 1.86 3.74 1.55 13A6 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2" X 3/4" 2.36 1.86 3.74 1.55 13A6 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2" x 1 2.67 2.04 314 1.55 13A6 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2' X 1/20 2.61 2.11 4.25 1.80 1/16 0.90 66.3 53.6 108.0 45.7 30.2 0.4 21/2 x 3/" 2.61 2.11 4.25 1.80 13A6 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2" X i 2.92 2.29 4.25 1.80 13A6 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 11/4 x 1" 8 11/20 x 1' 6 2"xl" 6 21/2 x 10 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (0=120) pipe. Page 2 of 2 TFP172O Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. General Notes: It is the Designer's responsibility to select products suitable for the intended service and to ensure that pressure ratings and performance data is not exceeded. Always read and understand the installation instructions (11-1-1000). Never remove any piping component or corrector modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Bulletin 136 Rev.O liableo Model Fl FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC. UK) NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-STD 167-1 Verband der Shhadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VNIV Patents: US Patent No. 6,374,920 Applies to Model FIFR Vertical Sidewall Sprinklers. Product Description Reliable Models Fl FR and Fl FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Model F1FR Model F1FR Recessed ,#,.,uick Response Sprinklers Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall Recessed Perideni HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must he exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-81N or other applicable standards. Quick response sprinklers and standard response sprinklers should not be intermixed. The Reliable Automatic Sprinkler Co., Inc. 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: K Factor SprinklerType Sprinkler Approval us M Height Organization F- .. . ............. . ...... ....... Standard.Uoriciht (8Sf it ond Pendnt (SSP) nfl.tnrR Mrkd to indir.Rtp PoUition Sprinkler Identification Number (SIN) SSU - ...............ssp...... (15mm) Standard Orifice with NPT(R)Thread - --- - - 56 - -------- -- 50 29 (56mm) 1234567 R3625W R3615 (20mm) Large Orifice with " NPT (R74)Tliread 8.0 115 2.3 (58mm) 1234,7,8 R3622W 83612 (17mm) Small Orifice with i" NFl (R)) Thread 4.2 60 2.2" (56mm) 1.2,8 133623 83613 i'(i0mrn)SmalIOriHcewith ........ ... 221 18 .._ .... .10.rn P.e ....2 6P........] 56m..4,6.7 ......................................P614 p00. D i9nal-Install in Upright Pendent ss.hs................................................................ 10mm Orifice XLH with R Thread 4.2 60 56mm --- R3674 15mm Standard Orifice with 4," NPT (R ) Thread 5.6 80 56mm 4,6,7 83675 - - ............................ Polyester coated uriht UL and ULC listed corrosion resistant. Upright Pendent Conventional Model F1 FR Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data: Nominal Thread K factor Sprinkler Approval Sprinkler Identification Orifice Size US Metric Height Organizations Number (SIN) p' (15mm) 4," NPT( ½) 5.6 80 2.2(56mm) 1,2,34,57.8 R3615 11? (20mm) " NPT (R3/4) 8.0 115 2.3" (58mm) 1.2,3,8 83612 3" (11mm) NPT (RV.,?) 4.2 60 2.2" (56mm) 1,2,8 R3613 " (10mm) ,çNPT (R½) 2.8 40 2.2 (56mm) 1,2,8 83611 10mm 4.2 60 56mm 4,7 83614 Heter to escutcheon data table for approvals and dimensions. 2 /4 1'JL/ LEA /2 ,.,,DO — I ...SEDUCER ?URN COLLAR 1,51/2 59/1 I- - .451 /19/ 'N/IL//I S/NC/I 1/6US .......... / FA F ..........................4........................................ I 227/324/1 !72.2 ,.,,1 31/ROLE (I) RE/FR TO Fl S FR (5F9/S//EON /9/2 EARLE FOR IFPRO///IUAND 2 52/9' £U/. [66.7m;,17 ...... 1/0,1 l's :202 NE 1-.. 2 5/16 -- ( 1-1 I -'- 7/22 11'E.fN/CEI;' 1, W1-1 S/N -- A /2/ FrI/NO ' iJ Eli TO T I. 2/3 '/'IEIIEWT ,,-" ....-........... --.--..—.. —-- /35.19019.4 07 12FF/IL TO £SCUTC,/IEO/1 DATA 54/ILL FOR APPRL2UIE1c 4/45/ D/I2FNSiONS. Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Thread K Factor Sprinkler Approval Id Sprinkler entification Orifice Size US f' Metric Height Organizations Number (SIN) - ½ V!' NP....)R½) 5.6 80 2,2 (56mm) 1.2.3,6,8 ..................................................... .......... A3685 15mm ...... .............- .......................................... ... .... ... . ................ . .......... . ... .. ... ................ ... ... ..... ½' N P T (RV:r) 1 5.6 , 80 2.2" (56mm) 41') LPC Approval is for Pendent position only. Orientation Deflector to Ceiling Dimension (Mm. - Max.) Upright 4' 12" (102mm 305m m) Pet ................................:..1?1ff...: .... PF...... ......... . Vertical Sidewall US Patent No. 6,374,920 Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: 1 Approval Organizations K Factor j and Type of Approval Sprinkler Nominal Thread Sprinkler Light Ordinary Identification Number (SIN) Metric Orifice Size us Length Hazard Hazard YI:L. N L.... m)25,8 ............L2,5,8 LIIII I NOTE: UL. ULC and MEA Listing permits use with Fl or F2 recessed escutcheon. A '' 'i 'I T .'..' H.! .'. .-. I Horizontal Sidewall 191 Installation Quick response sprinklers are intended for installation as specified in NFPA 13, FM Global Loss Prevention Data Sheet 2-8N or other applicable standards. Quick response sprin- klers and standard response sprinklers should not be inter- mixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprin- kler Wrench, When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Sprinkler Classification Temperature Max. Ambient Bulb Temp. Color Ordinary 135 1 1m°F(38'c) Orange Ordinary 68 155 100°F(38'c) Red Intermediate i 79 I '175 1,50-F (66-C) Yellow Intermediate 93 200 1 1501F (66"C) Green High 141 286 225"F (107-C) Blue Not available for recessed sprinklers. Escutcheon Data Escutcheon 'A" Face of Fitting Model Apprt,vls Dimension 1 to Ceiling or i WI 1)1;" Fl 124,8 Max Recess (38.1 mm) Min Recess Y ' (5mm - 24mm) ........ F2 34578 ' Max Recess (38.1mm) iA A6" 1,2,.,,, Min Recess (5mm-17mm) 24mm Push-on! —_ 1.2 Max Recessed 1/2"(38.lrnm) Thread-off 1.2 , Mm Recessed Ar 1"(25Amm) . Max No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tie vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should he maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes (1)(2) Standard Finishes Bronze Brass Chrome Plated Chrome Plated 0 White Polyester Coaled("' White Painted Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Ott White Oft White Satin chrome Satin Chrome Itt Other finishes and colors are available on special order. Consult the factory for details. 12t FM Approvals is limited to bronze and brass, chrome or black plated finishes only. 131 PP Push-on/Thread-off escutcheon. 141 UL and ULC listed corrosion resistance. SIN numbers: 83621, 83622, R3623, 83625. Note: For )2" orifice pendent FM approved white polyester coated and UL approved white polyester corrosion resistant sprinklers refer to Bulletin 014. Ordering Information Specify: 1. Sprinkler Model 2, Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in [his bulletin is la be installed in a r-ordarice v m(h 41he latest pertinent "tanda r et InC National Fire Frol Simon Assoc ia I on Factory 81 sal Research Gomporaimori, or ott-mr similar organizations and, also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and cislnibuted by Reliable have been protecting life arid property for over 8oyears, and are installed and serviced by the most highly ctm.,atitiecl and reputa- ble sprinkler contractors located throughout the United States, Canada arid foreign countries Manufactured by The Reliable Automatic Sprinkler Co., Inc. JCX Fireyded Rell able (800)431-1588 Sales Offices (914)829-2042 Corporate Offices (800)848-6051 Sales rax Revision lines. indicate updated or new data www.retrablespririkler.com Internet Address SC. Printed in USA 3/07 P/N5999570027 -4o RED HEAD® Submittal Information CONCRETEANCHtIRING SPECIALISTS Multi-Set Il® SPECIFIED FOR ANCHORAGE 11 INTO CONCRETE I Drop-In, shell-type anchors feature an internally threaded, all-steel shell with expansion cone insert and flush embedment lip. 'Anchors are manufactured from zinc-plated carbon steel, 18-8 stainless steel and 316 stainless steel. Anchors should be installed with carbide tipped hammer drill bits made in accordance to ANSI B212.15-1994 specifications. Anchors should be tested to ASTM E488 criteria and listed by ICC (formerly ICBO). Anchors should also be listed by the following agencies as required by the local building code: UL, FM, City of Los Angeles, California State Fire Marshal and Cal Trans. APPROVALS/LISTINGS Meets or exceeds U.S. Government G.S.A. Specification A-A-55614 Type 1 (Formerly GSA: FF-S-325 Group VIII) Underwriters Laboratories Factory Mutual City of Los Angeles - #RR2748 California State Fire Marshal Caltrans INSTALLATION STEPS ° •-.o To set anchor flush with surface: ct-0 Drill hole to required embedment (see Table on page 73) Clean hole with pressurized air. o • Drive anchor flush with surface of concrete. 4: :p:.o::o.:o 4. Expand anchor with setting tool provided :JJ : (see chart). Anchor is properly expanded :.a.0.; when shoulder of setting tool is flush with top of anchor. To set anchor below surface: Drill hole deeper than anchor length. Thread bolt into anchor. Hammer anchor into hole until bolt head is at desired depth. Remove bolt and set anchor with setting tool. Ultimate Tension and Shear Values (Lbs/kN) in Concrete* 11n.(mm) BOLT ANCHOR DIA. DIA, In. MIN. EMBEDMENT DEPTH In. (Mm) ANCHOR TYPE TENSION Lbs. (kN) _____________________ SHEAR Lbs. (kN) f'c = 2000 PSI (13.8MPa) Vic= 4000 P51 (27.6 Wall f'c = 6000 PSI (41.4MPa) f'c> 2000 PSI (13.8MPa) 1/4 (6.4) 3/8 (9.5) 1 (25.4) RM, RL or 5RM-18-8 S.S. or 1,680 (7.5) 2,360 (10,5) 2,980 (13.3) 1,080 (4.8) 3/8 (9.5) 1/2 (12.7) 1-5/8 (41.3) 2,980 (13.3) or CL-Carbon 3,800 (16.9) 6;240 (27.8) 3,160 (14.1) 1/2 (12.7) 5/8 (15.9) 2 (50.0) 3,300 (14,7) 5,840 (26.0) 8,300 (36.9) 4,580 (20.4) 5/8 (15.9) 7/8 (22.2) 2-1/2 (63.5) 5300 (24.5) SSRM-316 S.S. 8,640 (38.4) 11,020 (49.0) 7,440 (33.1) 3/4 (19.1) 1 (25.4) 3-3/16 (81.0) 8,280 (36.8) 9,480 (42.2) 12,260 (54.5) 10,480 (46.6) xiiowaoie varues are oaseu upon a', ,o I 5dlLlI actor. uiviue op 'flu, anowasie lodu values. For continuous extreme low temperature applications, use stainless steel. Combined Tension and Shear Loading-for Multi-Set Anchors Allowable loads for anchors subjected to combined shear and tension forces are determined by the following equation: (Ps/Pt)"3+ (/Vt)"° 151 Ps = Applied tension load Vs = Applied shear load Pt =Allowable tension load Vt =Allowable shear load irRed Head' 10/09 1-800-899-7890 44 www.itwredhead.com QRED HEAD CON Submittal Information CRETE ANCHORING SPECIALISTS 1t ( Ultimate Tension and Shear Values (LbslkN) in Lightweight Concrete* BOLT ANCHOR MINIMUM ANCHOR LIGHTWEIGHT CONCRETE LOWER FLUTE OF STEEL DECK WITH DIA. DIA. EMBEDMENT TYPE ft = 3000 P51(20.7 MPa) LIGHTWEIGHT CONCRETE FILL In. (mm) In. (mm) DEPTH fe =3000 PSI 20.7MPa) In. (mm) TENSION SHEAR TENSION SHEAR Lbs. (kN) Lbs. (AN) Lbs. )kN) Lbs. (IaN) 3/8 (9.5) 1/2 (12.7) 1-5/8 (39.7) RM, RL 2,035 (9.1) 1,895 (8.4) 3,340 (14.9) 4,420 (19.6) or CL-Carbon or 1/2 (12.7) 5/8 (15.9) 2 (50.8) SRM-18-8 s.s. or 2,740 (12.2) 2750 (12.2) 3,200 (14.2) 4,940 (22.0) 5/8 (15.9) 7/8 (22.2) 2-1/2 (63.5) SSRM-316 S.S. 4,240 (18.9) 4,465 (19.9) 5,960 (26.5) 5,840 (26.0) 3/4 (19,1) 1 (25.4) 3-3/16 (81,0) 5,330 (23.7) 6,290 (28.0) 8,180 (36.4) 9,120 (40.6) Allowable values are based upon a 4 t 1 safety factor. Divide by 4 for allowable load values. - Recommended Edge and Spacing Distance Requirements* BOLT DRILL BIT I EMBEDMENT ANCHOR EDGE DISTANCE MIN. EDGE SPACING MIN. ALLOWABLE DIA. SIZE DEPTH TYPE REQUIRED TO DISTANCE AT WHICH REQUIRED TO SPACING In. (mm) In. (mm) In. (mm) OBTAIN MAX. LOAD FACTOR APPLIED OBTAIN MAX. BETWEEN ANCHORS WORKING LOAD =80 FOR TENSION WORKING LOAD LOAD FACTOR APPLIED In. (mm) =70 FOR SHEAR In. (mm) =80 FOR TENSION In. (mm) =.55 FOR SHEAR In. (mm) 1/4 (6.4) 3/8 (9.5) 1 (25.4) R or SRM-18-8 5.5. 01 1-3/4 (4.4.5) 7/8 (22.2) 3-1/2 (88.9) 1-3/4 (44.5) 3/8 (9.5) 1/2 (12.7) 1-5/8 (41,3) or CL-Carbon 2-7/8 (73.0) 1-7/16 (36.5) 5-11/16 (144.5) 2-7/8 (73.0) 1/2 (12.7) 5/0 (15.9) 2 (50.8) ' 3-1/2 (88.9) 1-3/4 (44.5) 7 (177.8) 3-1/2 (88.9) 5/8 (15.9) 7/8 (22.2) 2-1/2 (63.5) 4-3/8 (111.1) 2-3/16 (55.6) 8-3/4 (222.3) 4-3/8 (111.1) SSRM-316 S.S. 3/4 (19.1) 1 (25.4) 3-3/16 (81.0) ________________________ 5-5/8 (142.9) 2-13/16 (71.4) 11-3/16 (284.2) 1 5-5/8 (142.9) Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Linear interpolation may be used for ivternsediate spacing and edge distances A _fj_. -jlj Ultimate Tension and Shear Values (LbslkN) for RX-series !Ji.1(3/4" and 1"Embedment)* BOLT DIA. DRILL BIT EMBEDMENT 2500 PSI (17.2 MPa) CONCRETE 4000 PSI (27.6 MPa) CONCRETE HOLLOWCORE In. (mm) SIZE In. (mm) TENSION SHEAR TENSION SHEAR TENSION SHEAR In. (mm) Lbs.(IaN) 2,295 00.2) Lbs. (IaN) Lbs. (IaN) Lbs. (kN) 2,401 (10.7) 3/8 (9.5/ 1/2 (12.7) 3/4 (19.1) 1,571 (7.0) 2,295 (10.2) 1,907 (8.8) 2,903 (12.9) 1,908 (8.5) 2,401 (10.7) 1/2 (12.7) 5/8 (15.9) 1 (25.4) 2,113 (9.4) 2,585 (11.5) 2,673 (11.9) 3,270 (14.5) 2,462 (11.0) 2,401 (10.7) ° The tabulated values are for 00 anchors installed at a minimum of 12 diameters an (enter and minimum edge distance of diameters for 100 percent anchor efficiency. Spacing and edge distance maybe reduced 106 diameters spacing and I diameter edge distance provided the values are reduced 50 percent. Linear Interpolation maybe used for intermediate spacings and edge margins. Allowable values are based upon a 4101 safety factor. Divide by 4 for allowable load values. pa - Anchoring Overhead in 3000 PSI AX Drop-(n Mnftr( Deck Installed to Lightweight Concrete On Metal Deck Lower Flute Upper Flute ANCHOR DRILL HOLE EMBEDMENT 3000PSI(20.7 MPa(CONCRETE DIAMETER In. (mm) ULTIMATE TENSION LOAD ) ALLOWABLE WORKING LOAD In. (mm) Lbs.(kN)I ALLOWABLE WORKING RX-38 Drop-In 1/2 (12.7) 3/4 (19.1) Upper Flute 1,410 (6.3) 353 (1.6) Lower Flute _1,206 (5.4) 301 (1.3) Allowable values are based upon a 410 1 safety factor. Divide by 4 for allowable load values, imRed Head' 10/09 1-800-899-7890 45 www.itwredhead.com P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - 3/8' and /2" rod. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTINGS - US 203-EX 2551 Approval guide - Pipe Hangers FUNCTION - Hanger assembly attachment to steel flange with thickness of less than 3/4". INSTALLATION Per NFPi\ 13 with set screw up or down. Torque - 3/8= 60 inch lbs. or 1/2= 125 inch lbs. in the absence of torque wrench, engage set bolt finger tight then additionally tighten 1/3 turn. FEATURES * Listings allow installation with set: screw up or clown - see drawings. Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back to prevent twisting on flange during installation. ORDERING - Part #, rod size and finish. 108 551 S.. 'S 300 S SSS SSo P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 Listed only for use with AFCON#300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel. CPVC, or copper pipe. Snap into locking position on swivel nut ofAFCON 4300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with .4FCOI'J#300 Ring Hanger. ORDERING - Part # and size. Sttccuf,c .tJ'COPV prorluicts are exclusively designed to be eonspatible ONLY with other .4PCON products including harts and fasreneru. rcsudring in a fst:d sway brace, restrainer it haunter assembly, lie advised ow Ire following warranty restruenion still apply. DISC LAISILIt-AF COIV will NOT warrant against the failure of its products when used in xnnhrn ntroo cvii scriber products, tarts or .cystetsus not ntautathucturenl or sold by .41''COV, AFCON altoS NO] he table under any eurcuuntsenuees whatsoever for any siiv5 in indirect, incidental or cuuiseu1uu;ntiiui daut iges si.uuus' Hunt. instating but not itnnted to loss of husunesn or profit. svlren nout.A hCOV products, have been, or ore used. 1/08 REC. LOAD LBS. METRIC' PIPE ROD 0IMPNERIALMAX 400 I 400 20 400 25 II 11/4 3/8 400 32 11/2 3/8 400 40 III 2 3/8 400 SO I/I 21/2 3/8 600 65 it) 3 3/8 6011 80 III 31/2 3/8 1 600 Ill 4 3/8 1 1000 100 10 5 1/2 1250 125 12 6 1/2 1250 /50 12 8 1/2 1250 200 0 'Oroer Part 11300m Note: 112 Ring Hanger not <FM> approved / inch pipe 5 thru 8 inch pipe FCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org KM I 1k[n: y4IeJ 3/4 thru 4 inch pipe LISTED FOR STEEL/CPVC SIZE - 1/2 thru 9 inch pipe. MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 2551 Approval guide - Pipe Hangers OSHPI) 0PA-0601 See Website. CONFORMS WITH: Federal Specification WW-i-1-171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION - Per NFPA 13, 13R, I3D and CPVC manufacturers instructions. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: \'eriI' that all assembly components are cleaned of any surface oil. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 5108 /Z Fg go, 0 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension 7- SIZE- One size fits both 3/8 and 1/2' rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: 1" L-dimension is measured from hanger rod center to the strap end. FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 P:./FCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 650 ALL THREADED ROD 10' -0' LENGTHS ROD MAX. REC. LOAD LBS. SIZE FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 1 4960 4420 11/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru I 1/2 inch rod in 10' - 0" lengths. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. ORDERING - Part #, rod diameter and finish. ED 3/00