HomeMy WebLinkAbout2502 EL CAMINO REAL; ; FPC2019-0231; Permitity of Carlsbad Print Date: 01/13/2022 Job Address: 2502 EL CAM INO REAL, CARLSBAD, CA 92008-1201 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel 4: 1670305000 Track 4: Valuation: $765,089.50 Lot 4: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check if: Plan Check if: Permit No: FPC2019-0231 Status: Closed - Finaled Applied: 10/01/2019 Issued: 10/21/2019 Finaled Close Out: 11/21/2019 Inspector: Final Inspection: Project Title: Description: PLANET FITNESS -NEW ADDRESSABLE FIRE ALARM (48 DEVICES, 16,450 SQ. FT. EXISTING BLDG) Applicant: FPContractor: ALLIANCE ELECTRIC DE LA 0 ALLIANCE INC BRIAN PARTUSCH 1885W COMMONWEALTH AVE. 4 STE N 1885W COMMONWEALTH AVE, if STE N FULLERTON, CA 92833-3029 FULLERTON, CA 92833-3029 (714) 213-2726 (619)962-3900 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov DEVICE LEGEND DEVICE SYMBOL QTY. MANUFACTURER PART NO. DESCRIPTION CSFM 1 FIRELITE MS-9050UD FIRE ALARM CONTROL PANEL 7165-0075:0210 EIJ 1 FIRELITE FCPS-24F56 TO A, 120 VAC REMOTE CHARGER 7315-0076:0206 POWER SUPPLY -- 1 FIRELITE ANN-80 ANNUNCIATOR 7120-0075:0211 DACT --- 1 -,-- TELGUARD --- TG-7 CDMA ----- WIRELESS COMMERCIAL FIRE MMNQR 7300-1402:0109 -- WHITE, ADDRESSABLE I FIRELITE SD365/13300-6 PHOTOELECTRIC DETECTOR, 7272-0075:0502 STANDARD BASE B FIRELITE D355PL PHOTOELECTRIC LOW FLOW 3240-0075:0221 SMOKE DETECTOR HOUSING. NetU 3 SYSTEM SENSOR RA100Z REMOTE ANNUNCIATOR LED 7300-1653:0212 3 FIRELITE BG-12LX ALPUL STATION WITH INTERFACE 7150-0075:0184 MODULE _MOUNTED _INSIDE ADDRESSABLE DUAL MONITOR 2 FIRELITE MDF-300 MODULE W/ FLASHSCAN, 7300-0075:0185 2 SUPERVISES CLASS A OR CLASS I ----- '' ADDRESSABLE MONITOR MODULE 3 FIRELITE MMF-300 W/ FLASHSCAN, SUPERVISES 7300-0075:0185 CLASS AOR CLASS BOF DRY CONTACT_INPUT CONTAINING TWO ISOLATED SETS OF FORM-C CONTACTS, WHICH RM I FIRELITE CRF-300 OPERATE AS A DPDT SWITCH. 7300-0075:0185 MOUNTS DIRECTLY TO A 4.0" --- (10.16 CM.) BOX, SURFACE MOUNT NHESMB5OU. __ 7 SYSTEM SENSOR SCRL STROBE, RED 7300-1653:0173 16 SYSTEM SENSOR PC2RL 2-WIRE, HORN STROBE, RED 7125-1653:0504 ENAY 55&' CONVENTIONAL 2 GENERIC WATERFLOW CONTACT DEVICE SWITCH 02 2 GENERIC TAMPER SWITCH TAMPER SWITCH 2o1c PLANET FITNESS fpc -O2 i 2502 EL CAM INO REAL CARLSBAD, CA 92008 MANUFACTURER'S EQUIPMENT DATA SHEETS DF-52418:E1 • A1-20 MS-9050UD(E) Fire Alarm Control Panel with DACT General The Fire•Lite MS-9050UD(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. This compact, intelligent addressable control panel supports up to 50 addressable devices of any type of detectors and modules. With an exten- sive list of powerful features, the MS-9050UD programs just like Fire•Lite's larger products, yet fits into applications previously served only by conventional panels. The MS-9050UD's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the pub- lic switched telephone network. It also allows remote and local programming of the control panel using the PK-CD Upload/ Download utility. In addition, the control panel may be pro- grammed or interrogated off-site via the public switched tele- phone network. Any personal computer with Windows 95 or greater, and compatible modem with a speed of 14.4 kbps or faster and Fire•Lite Upload/Download software kit PK-CD, may serve as a Service Terminal. This allows download of the entire program or upload of the entire program, history file, walk-test data, current status and system voltages. The power supply and all electronics are contained on a single circuit board supported on a new quick install chassis and housed in a metal cabinet. Available accessories include local and remote upload/download software, remote annunciators, and reverse polarity/city box transmitter. (4XTMF) New options include a UL listed printer, PRN-6F and the new IPDACT Internet Monitoring module.The FireWatch Series inter- net monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two telephone lines. Although not required, the second- ary telephone line may be retained providing backup communi- cation over the public switched telephone line. NOTE: Unless otherwise specified, the term MS-9050UD is used in this data sheet to refer to both the MS-9050UD and the MS- 905OUDE FACPs. For MS-905OUDC, refer to DF-60445. Features Listed to UL Standard 864, 9th edition. Auto-program (learn mode) reduces installation time. Reports two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style Y (Class B) NAC circuits. Selectable strobe synchronization for System Sensor, Whee- lock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. (a Flre•LUTff arms by Honeywell Point trouble identification. Waterfiow selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- lation is excessive. One-person audible or silent walk test with walk-test log and printout. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point (NFPA 72 compliant). Up to eight ANN-BUS annunciators Remote Acknowledge, Alarm Silence, Reset and Drill via addressable modules or remote annunciator. Upload/Download (local or remote) of program and data via integral DACT. SLC COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 and 7 requirements. 50 addressable device capacity (any combination of address- able detectors and modules). Compatible with Fire•Lite's addressable devices (refer to SLC Wiring Manual). NOTIFICATION APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits can be configured for the following outputs: - Style Y (Class B) - Style Z (Class A) - Door Holder Service (cannot be used for notification appliances) - Aux Power Source (cannot be used for notification appliances) Silence Inhibit and Autosilence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 A total power for NACs. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and the ANN-BUS is 2.7 A. DF-52418:E1 • 1/27/12 - Page 1 of 4 PROGRAMMING AND SOFTWARE Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 20 software zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. OFFLINE PROGRAMMING: Create the entire program in your office using a Windows®-based software package(order programming kit PK-CD, containing PS-Tools, separately). Upload/download system programming locally. User interface LED INDICATORS AC Power (green) Fire Alarm (red) Supervisory (yellow) Trouble (yellow) Alarm Silenced signals (yellow) KEYPAD 16 key alpha-numeric pad Acknowledge/Step Alarm Silenced Drill (Manual Evacuate) Reset (lamp test) Product Line Information MS-9050UD(E): Combination DACT/Fire Alarm Control Panel with one SLC loop. Includes main circuit board with display, chassis with transformer, backbox with door, plastic bag contain- ing screws, cables, key, etc., manual. (For MS-905OUDC, refer to DF-60445.) PK-CD: Contains PS-Tools programming software for Win- dows®-based PC computer (cable not included). DP-51050: Optional dress panel for the MS-9050UD. TR-CE: Optional trim ring for semi-flush mounting. BB-2F: Optional cabinet for one or two modules. BB-6F: Optional cabinet for up to six modules mounted on CHS-6 chassis. BB-26: Battery backbox, holds up to two 25 AH batteries and CHG-75. BB-55F: Battery box, houses two 55 AH batteries CHS-6: Chassis, mounts up to six multi-modules in a BB-6F cabinet. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120F: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional BB-55F for mounting. BAT Series: Batteries, see data sheet DF-52397. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6F: UL listed compatible event printer. Uses tractor-fed paper. IPDACT, IPDACT-2/211.1111) Internet Monitoring Module: Mounts in bottom of enclosure with optional mounting kit (PN IPBRKT). Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- P2R Strobe Multi-Modules CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit Supervised Control Module MMF-302-6 Six-Zone Interface Module MMF-300-10 Ten-Input Monitor Module MS-9050UD ADDRESSABLE FIRE ALARM BG-12LX Addressable CONTROL PANEL Manual Pull Station Page 2 of 4— DF-52418:E1 • 1/27/12 net internet connection. Requires compatible Teldat Visoralarm Central Station Receiver. Can use DHCP or static IP. (See data sheet df-52424 for more information.) IPBRKT: Mounting kit for IPDACT-2/2UD in common enclosure. IPSPLT: Y-adaptor option allows connection of both panel dialer outputs to one IPDACT-2/2UD cable input. AC-TRMBLK: AC Terminal Block mounts to a metal bracket, in turn, mounts to the FACP chassis. Use AC-TRMBLK when wire nuts are not allowed for AC connections to the transformer. OPTIONAL MODULES 4XTMF Reverse Polarity Transmitter Module: Provides a supervised output for local energy municipal box transmitter, alarm and trouble. Includes a disable switch and disable trouble LED. ANN-SEC: Optional secondary ANN-BUS interface module. Note: Used only with firmware 3.0 or higher. COMPATIBLE ANNUNCIATORS ANN-80(-W): Remote LCD annunciator mimics the information displayed on the FACP LCD display. Recommended wire type is un-shielded. (Basic model is red; order -W version for white; see DF-52417.) ANN-I/O: LED Driver Module provides connections to a user supplied graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: Alarm, Trouble, and Supervisory. Ships with red enclo- sure. (See DF-60241.) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. Can be mounted inside the cabinet. (See DF-52431.) ANN-S/PC: Serial/Parallel Printer Gateway module provides a connection for a serial or parallel printer. (See DF-52429.) ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. CP355: Addressable low-profile ionization smoke detector. SD355: Addressable low-profile photoelectric smoke detector. SD355T: Addressable low-profile photoelectric smoke detector with thermal sensor. SD355R: Remote test capable addressable photoelectric smoke detector for use with DNR(W) duct detector housing. H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of- rise option. H355HT: Fast-response, low-profile heat detector that activates at 190°F/88°C. AD355: Low-profile, intelligent, "Adapt' multi-sensor detector (B350LP base included). BEAM355: Intelligent beam smoke detector. BEAM355S: Intelligent beam smoke detector with integral sen- sitivity test. D355PL: InnovairFIex low-flow non-relay duct-detector housing; includes SD355R. DNR: InnovairFIex low-flow non-relay duct-detector housing. (Order SD355R separately.) DNRW: InnovairFIex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight. (Order SD355R separately.) MMF-300: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0(10.16cm.) box. Includes plastic cover plate and end-of-line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. MDF-300: Dual Monitor Module. Same as MMF-300 except it provides two Style B (Class B) only lDCs. MMF-301: Miniature version of MMF-300. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. MMF-302A: Similar to MMF-300A. Addressable Monitor Module for one zone of conventional two-wire detectors. Requires reset- table 24 VDC power. Refer to the Device Compatibility Docu- ment for listed compatible devices and quantity limitation. CMF-300: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0 (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power noti- fication appliances. CRF-300: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0 (10.16 cm.) box, surface mount using the SMB500. BG-12LX: Addressable manual pull station with interface mod- ule mounted inside. 1300: This module isolates the SLC loop from short circuit condi- tions (required for Style 6 or 7 operation). SMB500: Used to mount all modules except the MMF-301 and M301. MMF-300-10: Ten-input monitor module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. MMF-302-6: Six-zone interface module. Mount one or two mod- ules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. CMF-300-6: Six-circuit supervised control module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-617 cabinet. CRF-300-6: Six-relay control module (Form-C relays). Mount one or two modules in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 chassis in a BB-6F cabinet. NOTE: For more information on Compatible Addressable Devices for use with the MS-9050UD, see the following data sheets (docu- ment numbers): AD355 (DF-52386), BG-I2LX (DF-52013), CMF- 300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF- 52 130), CP355 (DF-52383), H355 Series (DF-52385), 1300 (DF- 52389), MMF-300 Series/MDF-300 (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), 5D355/5D355T (OF- 52384). ADDRESSABLE DEVICE ACCESSORIES End-of-Line Resistor Assembly (R-47K and R-3.9K): The 47k ohm assembly supervises the MMF-300, MDF-300, MMF- 301, and CMF-300 module circuits. The 3.9k ohm assembly supervises the MMF-302 module circuit. These resistors are included with each module. Power Supervision Relay: Supervises the power to 4-wire smoke detectors and notification appliances. Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Refer to the panel manual for wiring details. DF-52418:E1 • 1/27/12 - Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits.........................................1 Addressable device capacity..............................................50 Programmable software zones...........................................20 Annunciators.........................................................................8 Electrical Specifications AC Power: MS-9050UD 120 VAC, 60 Hz, 3.0 A. MS-905OUDE: 240 VAC, 50 Hz, 1.5 A. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Nonpower-limited, supervised. Battery: Two 12 V 18 AH lead-acid batteries. Battery Charger Capacity: 7-18 AH (MS-9050UD cabinet holds maximum of two 18 AH batteries.) Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Terminal Block provides con- nections for two NACs, Style Y (Class B) or Style Z (Class A). Special Application power. Power-limited, supervised circuitry. Maximum signaling current per circuit: 2.5 A. End-of-Line Resis- tor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Style Y (Class B) NAC. Refer to the Fire•Lite Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). Form-C relays, nonpower-limited, nonsupervised. Cabinet Specifications Door: 19.26 (48.92 cm.) high x 16.82 (42.73 cm.) wide x 0.72' (1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TA-CE): 22.00 (55.88 cm.) high x 19.65" (49.91 cm.) wide. Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (non- condensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the systems standby batteries and the electronic compo- nents may be adversely affected by extreme temperature ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C/60 - 80°F NFPA Standards The MS-9050UD(E) complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTMF). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTMF is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - OT, PSDN (Other Technologies, Packet-switched Data Net- work) Agency Listings and Approvals The listings and approvals below apply to the basic MS- 9050UD(E) control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S624 FM approved CSFM: 7165-0075:210 MEA: 442-06-E NOTE: See DF-60445 for ULC-listed model. FireLite® Alarms® and System Sensor® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. ________________ We try to keep our product information up-to-date and accurate. 933C3333= We cannot cover all specific applications or anticipate all requirements. _____________ All specifications are subject to change without notice. ______________ QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 of 4— DF-52418:E1 • 1/27/12 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0075:0210 Page 1 of I CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Model MS-9050UD addressable fire alarm control unit. Unit consists of one communication loop, two bell circuits, and three relay contact outputs for alarm, trouble and supervisory. Local, auxiliary, remote station, central station and proprietary (protected premise), automatic, manual, water flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 3.0 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 07-07-2006 rI This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52301 :A2 • D-025 FCPS-24FS6 24 Volt, 6 Amp Power Supply General The Fire-Lite FCPS-24FS6(C/E) is a compact, cost-effec- tive, 6-amp remote power supplies with battery charger. The FCPS-24FS6(C/E) may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may stand-alone. Primary appli- cations include notification appliance (bell) circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either two Class B (Style Y) and Class A (Style Z, with ZNAC-4 option module) or four class B only. Alternately, the four outputs may be configured as any combination of resettable/non-resettable power outputs (optimal for powering four-wire smoke detec- tors. The FFCPS-24FS6(C/E) also contains a battery charger capable of charging up to 7.0 Amp hour batteries. FCPS- 24FS6(C/E) is ULC-listed. NOTE: Unless otherwise specified, the term FCPS-24FS6 used in this document refers to the standard FCPS-24FS6, FCPS- 24FS6C, FCPS-24FS6E Features UL-Listed Notification Appliance Circuit (NAC) synchroniza- tion using System Sensor, Wheelock, or Gentex "Com- mander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently 'ON" (stand-alone mode). Two Class B (Style Y) or Class A (Style Z, with ZNAC-4 module) NACs (circuits 1 & 3) 6-amp full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated bell power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5"W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). (a FureLITe'ALarms by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24FS6: 120 VAC, 60 Hz, 3.2A maximum. FCPS-24F56/E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 -16V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-24F: 4.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-24F: 6.0 A maximum. DF-52301 :A2 • 5/17/13 - Page 1 of 4 Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. Float-charge voltage: 27.6 VDC. Maximum current charge: 250 mA. Maximum battery capacity: 7.0 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A. Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP noti- fication appliance circuits will activate the FCPS when reverse- polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A. Both resettable and non-reset- table power options are available. Resettable outputs are cre- ated by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. *NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 10,000 feet (3,046 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24F56 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-24F56 is configured (via DIP switch settings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input ter- minal. The pulses originate from an upstream FACP or other power supply. When the FCPS-24F56 is configured (via DIP switch settings) as a "sync generator:' the FCPS's sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchro- nization pulses on the FCPS's NAC outputs. In "sync genera- tor" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24F56 complies with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Page 2 of 4— DF-52301 :A2 • 5/17/13 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2424, S1287 ULC Listed: S2424 CSFM Approved: 7315-0076:176 MEA: 387-94E Ordering Information FCPS-24FS6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24FS6 is ULC-Iisted. FCPS-24FS6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required). PS-1270: Battery, 12-volt, 7.0 AH (two required). 90286: Optional module mounting kit, is required to install an addressable module on the power supply main circuit board. NOTE: All NAC outputs can be converted to Style Z with Style Y NAC or ZNAC-4 option module. FCPS Door Holder Trouble Power Style Y NAC Style Y NAC Style Y NAC Contact Output #4 Output #3 Output #2 Output #1 Output t t t t t 24 VDC Specific W* Application Power AC NAC Control Power 400 Input #2 INPUT/OUTPUT (from FACP) FUNCTIONS are programmable by NAC Control SWI DIP switch settings IUIIU Input #1 (from FACP) Sync Input FCPS Battery Charger Simplified Block Diagram DF-52301 :A2 • 5/17/13 - Page 3 of 4 T132: Power-Limited, NAC/Out I + Supervised in NAG Mode NAG/Out 1 - with Jumpers J5, JP6, NAC/Out 2 + TBI: Supervised JP7, & JP8 in positions NAG/Out 2 - - Earth shown below. NAG/Out 3 + NAC/Out 3 - — AC Neutral NAC/Out 4 + AG Hot NAG/Out 4— I I I ciico 3 g.r CD 30 3 CD(D CD 3 0 CD B_ 0- •j:1j CD 0 CD 1 CD CD CD (0 CD CD c 0 CD C 5) o. NCD CD C CD 0 D — TB1 — — 0J2 IOU CL 1< 0 Non-Power-Limited J2: To Transformer #2 H-9 JI: To Transformer #1 04 o l° Battery Fuse 15A, 30 V rm JP4 D[1 liii ©©©©© LL - Battery LEDs (L to R): AG Power (green) + Battery Ground Fault (yellow) JP4: Supervised, Battery Trouble (yellow) Non-Power-Limited NAG Trouble (yellow) 18 AH, 24 VDG Charger Trouble/AG Loss (ye/low) Auxiliary Output: 10 - —Aux. Common 500 MA Specific- Application Power + Aux. 24 VDC* - - Control Input 2 D - + Control Input 2 7 8 - - Out Common 5 + Out/Trouble Contact 4 - - Control Input 1 3 - + Control Input 1 2 - - Sync Input swi 1 - Sync Input Lhiuui ID o T134 + *NOTE: Auxiliary Power Output is power-limited but NOT supervised. SWI: Programming DIP Switches Normally Open Normally Closed Common TB5: Trouble Relay 0 Form-C Fail-Safe o (shown energized) 3 2 1 TB5 JPI: Ground Fault Detection jpi (cut to disable) JP2 JP3 Connector JP2 & JP3: Coded/Non-Coded Input Selection CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 700J_r LISTING SERVICE LISTING No. 7315-0075:0206 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett©Honeywell.com DESIGN: Models FCPS-24F56 and FCPS-24F58 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product designation, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. NOTE: *Rev. 05-06-05JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division ANN-80 80-Character Serial LCD Annunciator General The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employ- ing the ANN-Bus communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. The ANN-80 is red; for white, order ANN-80-W. The ANN-80 displays English-language text of system point informa- tion including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes control switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight ANN-80s may be connected to the ANN-Bus of each FACP. No programming is required, which saves time during system commissioning. Features Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, and Reset Control switches can be independently enabled or disabled at the FACP Keyswitch enables/disables control switches and mechanically locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, and Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and requires minimal panel programming Displays device type identifiers, individual point alarm, trouble, supervisory, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4" square electrical box Semi-flush mount to single, double, or 4" square electrical box. Use ANN-5B80K1T for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the panel Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus Controls and Indicators AC Power Alarm Trouble DF-52417:D • B-90 8 HIS' ietarms by Honeywell Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum Ambient temperature: 32°F to 120°F (0°C to 49°C) Relative humidity: 93% ± 2% RH (non-condensing) at 32°C ± 2°C(90°F±3°F) 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375" (3.49 cm.) deep For use indoors in a dry location All connections are power-limited and supervised The ANN-Bus POWERING THE DEVICES ON THE ANN-BUS FROM AUXIL- IARY POWER SUPPLY The ANN-Bus can be powered by an auxiliary power supply when the maximum number of ANN-Bus devices exceeds the ANN-Bus power requirements. See the FACP manual for more information. ANN-BUS DEVICE ADDRESSING Each ANN-Bus device requires a unique address (ID Number) in order to communicate with the FACP. A maximum of 8 devices can be connected to the FACP ANN-Bus communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The ANN-80 connects to the FACP ANN-Bus communications cir- cuit. To determine the type of wire and the maximum wiring distance that can be used with FACP ANN-Bus accessory modules, it is nec- essary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-Bus refer to appropriate FACP manual. DF-52417:D • 3/15/2018 - Page 1 of 2 WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power circuit is acceptable. Power wire distance limitation is set by 1.2 volt maxi- mum line drop form source to end of circuit. All connections are power-limited and supervised. A maximum of eight ANN-80 modules may be connected to this circuit. Ordering Options ANN-80: Red 80 character LCD Annunciator. ANN-80.W: White, 80 character LCD Annunciator. ANN-SB80KIT-R: Red surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. Agency Listings and Approvals The listings and approvals below apply to the ANN-80. In some cases, certain modules may not be listed by certain approval agen- cies, or listing may be in process. Consult factory for latest listing status. UL: S2424 FM approved CSFM: 7120-0075:0211 MEA: 442-06-E Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. I SO 9001 We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. 1;bdl U 0011111011111119 FtW(IF*CIURINC QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. Country of Origin: USA www.firelite.com Page 2 of 2— DF-52417:D • 3/15/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION FEMME OFFICE OF THE STATE FIRE MARSHAL 71Q0"" LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING No. 7120-0075:0211 Page 1 of I CATEGORY: 7120 -- ANNUNCIATORS LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Model ANN-80 and *ANN..80w remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciators for use separately listed compatible fire alarm control units. Refer to Manufacturers Installation Manual for details. *Rev. 04-28-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division PRODUCT FEATURES Delivers full data reporting. Certified for use on the AT&T LTE network for sunset-free installations. :• Provides security supervision with automatic self-test and system trouble outputs. :- Supports multiple alarm formats. Utilizes advanced encryption technology for secure communications. :• Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard model TG-7 LTE-A provides backup cellular alarm communication solutions for commercial, retail, financial and fire system markets. Alarm signals are transmitted over the AT&T LTE network when the telephone line or data network has been disrupted or compromised. This ensures critical data will reach the designated monitoring station. Telguard uses advanced encryption technology for secure communications. Superior building penetration is achieved through maximum transmitting power. Telguard Portal Telguard Cellular Service I Advanced Reliability TE LG UARD 4METEK TG-7 I CELLULAR COMMUNICATOR ALARM LTE-A FOR LTE NETWORKS COMMERCIAL Telguard makes adopting cellular easy with a secure Internet portal. The straightforward web interface allows security dealers and central stations to quickly and efficiently access Telguard based services 24/7. This advanced tool has multi-level user authorization and provides total account management of UL Listed Telguard cellular alarm communicators. Telguard Cellular Service provides AT&T LTE network coverage for all Telguard units. Telguard's Communication Center is UL compliant and provides seamless connectivity between the alarm panel, the Telguard family of products and the central station. Telguard Technical Support provides a single point of contact for both cellular service and Telguard product questions. Two programmable supervisory trip outputs. Automatic Self-Tests with central station notification ensure the cellular system is operating. Diagnostic LEDs display unit functionality, operational mode or signal strength. 128 bit AES (Advanced Encryption Standard) alarm signals ensure authentication and security. TG-7 LIE-A CELLULAR ALARM COMMUNICATOR FOR LTE NETWORKS TELGUARD SAMETEK Power Transmit Power: 200 mW in all bands. 12VDC/Battery Consumption: <32mA (Standby) 160mA (Transmission). Transformer Supplied: 12VAC, 800mA UL listed plug-in. Radio Transceiver LTE Bands: 2, 4 & 17. 3G Bands: 2 & 5. Antenna: 9" dipole with 2dBi gain 12 ft of cable and universal mounting bracket. FCC part 15, 22, 24, 27 and 68 compliant. Physical Details TG-7 LTE-A: 7.5" H x 11.5" W x 3.5" D Shipping Weight: 81bs (with transformer). TG-7 LTE-A: 12"H x 12W x 4"D Shipping Weight: 18lbs. Attack chassis on TG-7A LTE-A for bank safe & vault application. Operating Environment: 0°C to +50°C; up to 95% humidity (non-condensing). Standard Features Full data reporting. Automatic self-test (daily, weekly or monthly). Locking metal enclosure. One available trip input. Alarm format support for 51A2, contact ID, pulse (3x1, 4x2), modem lie & 1I1a2, DMP. Telephone line monitor built-in. Accessories ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-O: External antenna. SECURITY UL Listings SIGNALING Commercial Burglary Residential C Ui. us 365 Police Station 985 • Household fire warning systems connected burglar 1023 Residential burglar alarm systems LISTED alarm units & systems 1610 • Central station burglar alarm units; Line security services ULC Listings S545 • Canadian household fire warning systems S304 Canadian commercial burglary alarm systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit wwwTelguard.com. , A LANA Connected Telguard, a Division of TelLilar Corporation 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 USA 800.2292326 1 telguard,com Copyright p2019 Telguard, a Business Unit of AMETEK, Inc. • All Rights Reserved CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of I CATEGORY: Fire Alarm Control Unit Accessories/Misc. Devices LISTEE: TELULAR CORP., 3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *1G7LA001 *TG7IfiA01 TG7LA002, *TG7IJF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7fiF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an \L/ endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Proqram Coordinator Fire Engineering Division SD365 Series Addressable Photoelectric Smoke Detectors DF-61 O1O:B (a Flre•uTe®Atarms by Honeywell The Fire-Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelli-gent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. Exclusively for use with Fire-Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- tor's address to be set with rotary, decimal address switches, provid- ing exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious res- cue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. The 5D365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the 5D365T(A) and a remote test capable detec- tor on the 5D365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features SLC LOOP: Two-wire SLC loop connection Unit uses base for wiring Compatible with LiteSpeedTM and CLIP protocol systems Stable communication technique with noise immunity ADDRESSING: Addressable by device Rotary, decimal addressing (Refer to the Fire-Lite panel manuals for device capacity.) ARCHITECTURE: Sleek, low-profile, stylish design ° Unique single-source design to respond quickly and dependably to a broad range of fires Integral communications and built-in device-type identification Built-in tamper resistant feature Remote test feature from the panel Walk test with address display (an address on 121 will blink the detector LED: 12-[pause]-l(LiteSpeed systems only) Built-in functional test switch activated by external magnet Removable cover and insect-resistant screen for simple field cleaning Expanded color options OPERATION: Designed to meet UL 268 7th Edition Factory preset at 1.5% nominal sensitivity for panel alarm thresh- old level LED "blinks" when the unit is polled (communicating with the fire panel) and latches in alarm. Low standby current MECHANICALS: Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct-surface or electrical-box mounting Plugs into separate base for ease of installation and maintenance Separate base allows interchange of photoelectric, ionization and thermal sensors OPTIONS: Optional relay, isolator, and sounder bases Installation SD365 Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5' (3.81 cm) deep. For a chart of compatible junction boxes, see DF-60059. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring only. When using relay or sounder bases, consult the 1300(A) installation sheet 156-3626 for device limitations between isolator modules and iso- lator bases. Construction These detectors are constructed of fire-resistant plastic. The 5D365 Series plug-in intelligent smoke detectors are designed to commer- cial standards and offer an attractive appearance. Operation Each 5D365 Series detector uses one of the panel's addresses (total limit is panel dependent) on the Fire-Lite Signaling Line Circuit (SLC). It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. Detector Sensitivity Test Each detector can have its sensitivity tested (required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance) when installed/ connected to an Fire-Lite addressable fire alarm control panel. The results of the sensitivity test can be printed for record keeping. DF-61010:B • 71/2019— Page 1 of 3 Product Line Information NOTE: "-IV" suffix indicates CLIP and LiteSpeed device. NOTE: "A" suffix indicates Canadian version. SD365: White, low-profile intelligent photoelectric sensor, LiteSpeed only SD365A: Same as SD365 but with ULC listing SD365-IV: Ivory, low-profile intelligent photoelectric sensor SD365A-IV: Same as SD365-IV but with ULC listing SD365T: White, same as SD365 but includes a built-in 135°F (57°C) fixed-temperature thermal device, LiteSpeed only SD365TA: Same as SD3651 but with ULC listing SD365T-IV: Ivory, same as SD3651 but includes a built-in 135°F (57°C) fixed-temperature thermal device SD365TA-IV: Same as 5D365T-IV but with ULC listing SD365R: White, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW, LiteSpeed only SD365RA: Same as SD365R but with ULC listing, for use with DNRA SD365R-IV: Ivory, low-profile intelligent photoelectric sensor, remote test capable, for use with DNR/DNRW SD365RA-IV: Same as SD365R-IV but with ULC listing, for use with DNRA INTELLIGENT BASES NOTE: For details on intelligent bases, see DF-60059. B300-6: White, 6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting base (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed B300-6-BP: Bulk pack of B300-6, package contains 10 B200SA-WH: Same as B2005-WH, ULC listing B200SA-IV: Same as B200S-IV, ULC listing B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO Series detector applications, ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B21OLP(A) base base. UL/ULC listed (CSFM: 7300-1653:0109) RAIOOZ(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box. For use with B501 (A) and B300-6(A). UL/ULC listed (CSFM: 7300-1653:0109) M02-04-00: Test magnet B5014V: Ivory color, 4" standard European flangeless mounting M02-09-00: Test magnet with telescoping handle base. UL/ULC listed (CSFM: 7300-1653:0109) CK300: Color Kit (includes cover and trim ring), white, 10-pack B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 B224RB-WH: White, relay base (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing B224RBA-IV: Ivory, relay base, ULC listing B224B1-WH: White, isolator detector base (CSFM: 7300-1653:0216) B224B1-IV: Ivory isolator detector base (CSFM: 7300-1653:0216) B224B1A-WH: White, isolator detector base, ULC listing B224B1A-IV: Ivory isolator detector base, ULC listing B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-pack CK300-BL: Color Kit (includes cover and trim ring), black, 10-pack Page 2 of 3— DF-61010:B • 71/2019 SYSTEM SPECIFICATIONS Sensitivity: UL Applications: 0.5% to 4.0% per foot obscuration. ULC Applications: 0.5% to 3.5% per foot obscuration Size: 2.0(5.3 cm) high; base determines diameter - B300-6: 6.1" (15.6 cm) diameter - B501: 4(10.2 cm) diameter For a complete list of detector bases see DF-60983 Shipping weight: 3.4 oz. (95 g) Operating temperature range: SD365: 32°F to 122°F (0°C to 50°C) SD365T Series: 32°F to 100°F(0°C to 38°C) 5D365R Series installed in a DNRIDNRW, -4°F to 158°F (-20°C to 70°C) ULIULC Listed Velocity Range: 0-4000 ft/mm. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10% - 93% non-condensing Thermal ratings: fixed-temperature set point 135°F (57°C), rate-of- rise detection 15°F (8.3°C) per minute, high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200pA @ 24 VDC (one communica- tion every 5 seconds with LED enabled) Max current: 4.5 mA @ 24 VDC (ON") DETECTOR SPACING AND APPLICATIONS Fire-Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9.1 m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. Listings and Approvals Listings and approvals below apply to the 5D365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: S1059 FM Approved CSFM: 7272-0075:0502 LiteSpeedTm is a trademark, and Fire-Lite® Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ©2019 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. :b All specifications are subject to change without notice. 4UlNI & MAI'4UMCI1RING QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX(877) 6994105. Country of Origin: Mexico www.firelite.com Page 3 of 3— DF-61010:B • 71/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0075:0502 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models 5D365, 5D365R and 5D365T analog addressable, photoelectric smoke detectors for open area and duct installations. Model 5D365T has a complementary heat detector. All models are similarl except for population/depopulation of components on the Printed Wiring Board for the intended features. All above models may be followed by two digit Suffix indicating the color of the detector enclosure: no suffix for white, -IV for ivory, -BL for black. Refer to listee's Installation and Maintenance Instruction for additional detailed product description and operational considerations. RATING: 24 VDC. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors. Detectors are for use with separately listed System Sensor base Models B200S and B200SR (CSFM Listing 7300-1653:0213), B200S-LF and B200SR-LF (CSFM Listing 7300-1653:0238), B300-6 and B300-6-IS bases (CSFM Listing 7300-1653:0109), System Sensor duct detector housings Models DNR and DNRW (CSFM listing 3240-1653:0209), Fire-Lite duct detector housing Model 0355PL (CSFM listing 3240-0075:0221) and separately listed compatible fire alarm control units. Refer to manufacturer's Installation Manual for details. XLF: 7272-0028:0503 02-01-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-60430:C2 • E-650 D355PL(A)/DNRW InnovairFiex Intelligent Non-Relay Photoelectric Duct Smoke Detector 8 FlreuTe'ALarms by Honeywell General The Fire•Lite InnovairFIex® 0355PL(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non- relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capa- ble of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 to 20.32 m/s), temperatures of -4°F to 158°F (-20°C to 70°C), and a humidity range of 0 to 95 percent (non-condensing.) An improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indi- cates a trouble signal for a removed or improperly installed sensor cover. The Fire•Lite InnovairFiex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- ing and mounting of a relay module. The Fire-Lite InnovairFIex duct smoke detector can be custom- ized to meet local codes and specifications without additional wiring. The new InnovairFIex product line is compatible with all previous Innovair models, including remote test accessories. Features Photoelectric, integrated low-flow technology. Air velocity rating from 100 ft/min to 4,000 ft/mm (0.5 m/s to 20.32 m/s). Versatile mounting options: square or rectangular configu- ration. Broad ranges for operating temperature (-4°F to 158°F, - 20°C to 70°C) and humidity (0% to 95% non-condensing). Patented sampling tube installs from front or back of the detector with no tools required. Cover tamper signal. Increased wiring space with a newly added 3/4" conduit knockout. Available space within housing to accommodate mounting of a relay module. Easily accessible code wheels on sensor head (sold sepa- rately). Clear cover for convenient visual inspection. Remote testing capability. Requires com line power only. Accommodates the installation of an addressable relay module, sold separately, (CRF-300) for applications requir- ing a Form-C relay. Specifications Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6.6 cm) Depti. Size: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6.35 cm) Depth. Weight: 1.6 lb (0.73 kg). Operating Temperature Range: -4°F to 158°F (-20°C to 70°C). Storage Temperature Range: -22°F to 158°F (-30°C to 70°C). Operating HumUity Range: 0% to 95% relative humidity (non-condensing) Air Duct Velocity: 100 to 4,000 ft/mm (0.5 to 20.32 m/s). Accessories Fire'Lite provides system flexibility with a variety of accesso- ries, including twc remote test stations and different means of visible and audilbJe system annunciation. As with our duct smoke detectors, ll duct smoke detectors accessories are UL listed. D355PLs and Dt.RWs with a date code of 0C13 or higher do not require external 24VDC for remote test applications when used with a remote-test-capable detector. ACCESSORY CURRENT LOADS AT24 VOC Device Standby Alarm RAIOOZ OnA 12 mA Max RTS151/ 0mA 12mA Max RTS151 KEY Agency Listings and Approvals Consult product manual tor lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. UL: S1059. ULC:S1059 DF-60430 C2 • 12/18/2012 - Page 1 of 2 CSFM: 3242-1653:0209. FM approved. Product Line Information D355PL: Intelligent non-relay photoelectric low flow smoke detector housing. Includes SD355R Detector. DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Does not include detector head. SD355R(A): Remote test capable addressable low-profile photoelectric smoke detector. SD355(A): Addressable low-profile photoelectric smoke detec- tor. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1: Metal sampling tube duct width up to 1 ft (0.3m). DST1.5: Metal sampling tube duct widths up to 1 It to 2 ft (0.3 to 0.6 m). DST3: Metal sampling tube duct widths up to 2 ft to 4 ft (0.6 to 1.2 m). DST5: Metal sampling tube duct widths up to 4 It to 8 ft (1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1: Weatherproof enclosure. ETX: Metal exhaust tube duct, width 1 ft (0.3 m). M02-04-00: Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. RTS151: Remote test station. RTS1 51 KEY: Remote test station with key lock. Important Note DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. _______________ We try to keep our product information up-to-date and accurate. ______________ We cannot cover all specific applications or anticipate all requirements. ______________ ENIM6II & MANUM11JRI All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-60430:C2 • 12/18/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0075:0221 Page 1 of I CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson©honeywell.com DESIGN: Model *D355PL analog photoelectric duct smoke detector housing. Unit consists of a duct detector housing, exhaust tubes, and separately listed Fire-Lite Alarms' Model SD355 or 5D355R detector heads (OSFM Listing No. 7272-0075:194). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instruction, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, air velocity and UL label. APPROVAL: Listed as conventional photoelectric duct smoke detector housing for use with separately listed fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 3240-1653:0209 01-02-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR® Duct Smoke Detector Accessories iiEE- _711 .1 ) f . Expand the versatility of the InnovairFlexTM line of duct smoke detectors with System Sensor notification and test accessories. Available Accessories APA151 Piezo Annunciator MHR Mini-Horn, Red MHW Mini-Horn, White RA1 OOZ/RA1 OOZA Remote Annunciator RTS151 Remote Test Station RTS151KEY Remote Test Station with Key RTS2 Multi-Signaling Accessory AOS Add-On Strobe RTS2-AOS Multi-Signaling Accessory Agency Listings ® 7300-1653:0212 C E LISTED APPROVED 7300-1653:0211 S2522 3034401 7135-1653:0196 9060301 Duct smoke detector accessories add functionality to the duct smoke detection system by allowing quick, convenient inspections at eye level and effective audible and visible notification options. All System Sensor duct smoke detectors and accessories are UL listed. The APAI5I piezo annunciator, which replaces the APA451 with a new, improved look, provides an audible alarm signal, a red LED to indicate alarm status, and a green LED to indicate power status. It is intended for use with System Sensor 4-wire conventional duct smoke detector applications without a system control panel, to comply with NFPA 90A. The MHR and MHW SpectrAlert® Advance mini-horns feature temporal or continuous tones at high and low volume settings. Their small footprint allows mounting to single-gang back boxes for applications where a small device is desired. The RAIOOZ and RAIOOZA remote annunciators are designed for both conventional and intelligent applications. Their red LED provides visual indication of an alarm condition. The RTSI5I and RTSI5I KEY remote test stations are automatic fire detector accessories designed to test duct smoke detectors from a convenient location. For 4-wire detectors, the RTS151KEY test station features a multi-colored LED that alternates between steady green and red. For 2-wire detectors, the LED illuminates red for alarm. The RTS2 and RTS2.AOS multi-signaling accessories are designed to work with lnnovairFlex 4-wire conventional duct smoke detectors. These accessories include a key switch that can be used to select one of two connected sensors to be tested, reset, or both by a push button switch. They also enable sensitivity measurements using the SENS-RDR sensitivity reader (sold separately). The AOS (Add-On Strobe) is an optional accessory included with the RTS2- AOS model. Specifications, Duct Smoke Detector Accessories Voltage Regulated 24 VDC Operating Voltage 16 to 33 VDC Maximum Alarm Current 30 mA Temperature Range 0°C to 49°C (32°F to 120°F) Relative Humidity 10 to 93% non-condensing Wire Gauge 12to18AWG Dimensions MHR/MHW SpectrAlertO Voltage 4.6-H x 2.9"W x .45"D Advance Mini-Horns Regulated 12 DC or FWR (Full Wave Rectified) or Regulated 24 VDC or F\NR Sounder Current Draw 22 mA RMS max. at 8 to 17.5 Volts DC 29 mA RMS max. at 16 to 33 Volts DC Temperature Range 0°C to 49°C (32°F to 120°F) Humidity Range 10 to 93% non-condensing Nominal Sounder Frequency 3 kHz Wire Gauge 12 to 18 AWG Dimensions 4.6" H x 2.9"W x 0.45" D I:LI0II'JA:L[0IIY&1Remote Annu Voltage Range Conventional System: 3.1 to 32 VDC Intelligent System: 18 to 32 VDC Maximum Alarm Current 10 mA Dimensions 4.6 "H x 2.8"W x 1.3"D Power Requirements Alarm LED: 2.8 to 32 VDC, 12 mA max Total Current: 105 mA max. Test Switch 10 VA @ 32 VDC Reset Switch 10 VA @ 32 VDC Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4.8"H x 2.90"W x 1.4"D RTSI 51 KEY Remote Test Power Requirements Station with Key Power LED (Green): 14 to 35 VDC, 12 mA max. Alarm LED (Red): 2.8 to 32 VDC, 12 mA max. Total Current: 105 mA max. Alarm Response Time 40 seconds max. Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 18 AWG Dimensions 4,6"H x 2.75"W x 1.8"D RTS2 and RTS2-AOS Multi Voltage -signaling Accessory 20 to 29 VDC Power Requirements Standby: 3.0 mA max. Trouble: 16.0 mA max. Alarm without strobe: 30 mA max. Alarm with strobe: 55 mA max. Sounder 85 dBA at ten feet Temperature Range —10°C to 60°C (14°F to 140°F) Relative Humidity 95% non-condensing Wire Gauge 14 to 22 AWG Dimensions 4.8"W x 5.3"H x 1.6" D For the very latest product specifications and listing information, please visit the System Sensor Web site at www.systemsensor.com I SMOKE I - I _ I LT APA151 UL S4011 RTS2-AOS UL S2522 I .. RA100Z UL S2522 MHW UL S4011 MHRULS4O11 AOS 3825 Ohio Avenue • St. Charles, IL 60174 ©2013 system Sensor. SEIVcOR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Visit syotemserrsor.corn for current product information, including the latest version of this data sheet. www.systemsensor.com HVDS20202 • eli 3 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0212 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models RTSI 51, RTSI 51 KEY and RA1 OOZ Duct Smoke Detector accessories. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Refer to the installation manuals. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 04-03-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the. test results and/or other data but does not make an independent verification or any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DF-52013:D • E-100 BG-1 2LX Addressable Manual Pull Station General The Fire-Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire-Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location Installation The BG-12LX will mount semi-flush into a single-gang, double- gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-b 0 or SB-I/O surface back- box. If the BG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is (a FIreLuTeALarms by Honeywell usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 - 159 with Breakaway Tab removed for MS-9600 Series, 1 - 99 and MS-9200UDLS, 1 —50 for MS-9050UD). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4° (10.16 cm) square electrical box, and shall be installed DF-52013:D • 4/13/2012 - Page 1 012 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17003: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S711 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0075:0184. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. FireLite® Alarms® is a registered trademark of Honeywell International Inc. ©2012 by Honeywell Intemationa Inc. All rights reserved. Unauthorized use of this document is strictly prohibi:ed. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and . i We cannot cover all specific applications or anticipate all requirements. EIIIIIIIERINS & MANIMCIURINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52013:D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:0184 Page 1 of I CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models BG-12, BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-I2WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12P5, BG-12LSP, BG-125P, BG-I2LR, BG-I2LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-I2LPS, BG-I2LPSP, BG-125L, UT-PSI and UT-P52 fire alarm pull boxes. The BG-I2 series is a dual action pull station that has normally open switch contacts. Refer to listees data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-12LW and BG-12LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12L0B are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division MMF-300(A) Series, MDF.300 Addressable Monitor Modules General Four different monitor modules are available for Fire-Lite's intelligent control panels to suit a variety of applications. Moni- tor modules are used to supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (MMF-302(A)). MMF-300(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. MMF-301(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that super- vises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the MMF-301(A) to be mounted in a single-gang box behind the device it monitors. MMF-302(A) is a standard-sized module used to monitor and supervise compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. MDF-300(A) is a standard-sized dual monitor module used to monitor and supervise two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire sys- tems. LiteSpeedTM is a communication protocol developed by Fire-Lite Engineering that greatly increases the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. MMF-300(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems. LED flashes during normal operation and latches on steady to indicate alarm. The MMF-300(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The MMF-300(A) can be used to replace M300(A) modules in existing systems. MMF-300(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special DF-52121:E • E-325 HreLITeALarms by Honeywell MMF-300(A) (Type H) supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. MMF-300(A) OPERATION Each MMF-300(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-300(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5° (11.43 cm) high x 4° (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125° (5.398 cm) deep box. MMF.301(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. DF-52121:E • 07/30/2015 - Page 1 of 4 Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on MS-9600 series panels, 01 - 99 on other compatible systems 1415 0 1 ADDRESS o 1 12 3 LOOP 3 0 %9-6 9 6 i TENS ONES H I'h : oH 11w 1° ..jII II-.j Lu 'q: jII 110 -1 H II Ia The MMF-301(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The MMF-301(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm devices. The MMF-301(A) can be used to replace M301 (A) modules in existing systems. MMF-301(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterfiow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/ device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. MMF-301(A) OPERATION Each MMF-301(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). MMF-301(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, I communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3° (3.302 cm) high x 2.75' (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6(15.24cm) minimum. MMF.302(A) Interface Module Supports compatible two-wire smoke detectors. Page 2 of 4— DF-52121:E • 07/30/2015 Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on MS-9600 series panels, 01 —99 on other compatible systems. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The MMF-302(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The MMF-302(A) can be used to replace M302(A) modules in existing systems. MMF-302 (A) APPLICATIONS Use the MMF-302(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across terminals 8 and 9 for Style D application. MMF-302(A) OPERATION Each MMF-302(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). MMF-302(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals T1 and T1 1): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) Dual Monitor Module The MDF-300(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The MDF-300(A) provides two Style B (Class B) IDC cir- cuits ONLY. Style D (Class A) IDC circuits are NOT supported in any application. MDF-300(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. MDF-300(A) AUTOMATIC ADDRESSING The MDF-300(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the MDF-300(A) is set to address "26", then it will automati- cally assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the MDF-300(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation MMF-300(A), MMF-302(A), and MDF-300(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The MMF-301(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424. ULC: S2424. FM Approved. CSFM: 7300-0075:0185. MEA:72-01-E. Product Line Information NOTE: °A" suffix indicates ULC-listed model. MMF-300(A): Monitor module. MMF-301(A): Monitor module, miniature. MMF-302(A): Monitor module, two-wire detectors. MDF-300(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51309. Architects/Engineers' Specifications Specifications of these devices and all FireLite products are available from FireLite. DF-52121:E • 07/30/2015- Page 3 of 4 Fire-LiteO is a registered trademark and LiteSpeed and FireWatchTm are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO ooi We try to keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. MCINEMIN & MN111111FACTING All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 4 0f4- DF-52121:E • 07/30/2015 df-60379:A1 • E-400 CRF-300(A) Relay Module General The CRF-300(A) Addressable Relay Module provides the sys- tem with a dry-contact output for activating a variety of auxil- iary devices, such as fans, door holders, dampers, control equipment, etc. Addressability allows the dry contact to be activated through panel programming, on a select basis. LiteSpeedTM is a communication protocol developed by Fire•Lite Engineering that greatly enhances the speed of com- munication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other designs. Features Built-in type identification automatically identifies these devices to the control panel. Internal circuitry and relay powered directly by two-wire SLC loop. Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady red when activated. High noise immunity (EMF/RFI). Wide viewing angle of LED. SEMS screws with clamping plates for wiring ease. Direct-dial entry of address: 01— 159 for MS-9600(A) series panels, 01 - 99 on MS-9200UDLS(A) and MS-9050UD(A). Applications The CRF-300(A) may be programmed to operate dry contacts for door holders, Air Handling Unit shutdown, etc., and to reset four-wire smoke detector power. Construction The face plate is made of off-white heat-resistant plastic. Controls include two rotary switches for direct-dial entry of address setting. The CRF-300(A) is configured for a single Class B (Style Y) or Class A (Style Z) Notification Appliance Circuit. The CRF-300(A) provides two Form-C dry contacts that switch together. Operation Each CRF-300(A) uses one of the addresses on a SLC loop. It responds to regular polls from the control panel and reports its type and status, including the open/normal/short status of its Notification Appliance Circuit (NAC). The LED blinks with each poll received. On command, it activates its internal relay. NOTE: Open/short supervision is suspended with the CRF-300. Rotary switches set a unique address for each module. The address may be set before or after mounting. The built-in TYPE CODE (not settable) will identify the module to the con- trol panel, so as to differentiate between a control module and a relay module. (a Flre.LuTeeALarms by Honeywell LUO EGfl44NI CRF-300(A) Specifications Normal operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA (LED on). Average operating current: 230 pA direct poll (CLIP mode), 255 pA group poll (LiteSpeed mode) with LED flashing. EOL resistance: not used. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% non-condensing. Dimensions: 4.5° (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125° (5.398 mm) deep box. Relay Contact Ratings Load Description Application Maximum voltage Current Rating Resistive Non-Coded 30 VDC 3.0 A Resistive Coded 30 VDC 2.0A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive (L/R=5m5) Coded 30 VDC 0.5 A Inductive (L/R2ms) Coded 30 VDC 1.0 A Inductive (PF=0.35) Non-Coded 125 VAC 0.5 A df-60379:A1 • 08/04/09 - Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S2424 ULC: S2424 FM approved CSFM: 7300-0075:185 MEA: 72-01-E Product Line Information CRF-300(A): Intelligent addressable relay module. Intelligent addressable relay module, ULC listed model. SMB500: Optional surface-mount backbox. NOTE: For installation instructions, see document 156-1190-005 and refer to the SLC Wiring Manual, document 51309. LiteSpeedTM is a trademark and Fire-Lite® Alarms is a registered trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. E= We cannot cover all specific applications or anticipate all requirements. BYSIMISHIS & MMDFAE1URIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— df-60379:A1 • 08/04/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0075:0185 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Pete Sennett (203) 484-7161 Fax (203) 484-7309 Email: pete.sennett@Honeywell.com DESIGN: Models MDF-300, MMF-301, MMF-300, MMF-302, MCF-300 monitor modules; Models CRF-300 and CMF-300 control modules; and MMF-302-6 six zone interface signaling device module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. NOTE: *Rev. 05-06-05 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR® Multi-Voltage Conventional Relays System Sensor multi-voltage conventional relays are used for high-current switching applications such as fan and damper assembly control, door control, air handling unit controls, and other types of system interfacing. Features Multi-voltage operation Activation LEDs Easy and flexible installation Reliable and robust design Multipurpose field installations Multi-voltage relays with terminal strip field wiring connections, mounting track, and hardware for R-1 OT/20T and R-1 41/241 Removable front cover on steel enclosure for R-1 OUR-20E and R- 14/R-24E, which mount inside the enclosure LED viewing hole on top of the steel enclosure's cover Extra pair of wires for redundant power input on PR-3 Terminal strip field wiring connections, mounting track, and hardware The R-10 R20T, R-11 4T, and the R-241 models are multi- vo16ge &ays wtlitermiral strip field wiring connections, mounting track, and ia:t:ware.The F-1 OT is single FORM—C (SPDT) relay with a rec activtic.n _ED, and ihe R-141 is a four-gang 1 FORM—C (SPDT) ela' wthour:ec actvaton LEDs. The R-20T is a single 2 FORM—C :D701) rey with a red activation LED, and the R-24T is a four-gang 2 RM—C DPDT) relay wit four red activation LEDs. The R-10EJR-20E and R-14E/R-24E are similar to the 1-series trac: nour 'slays but :hey are mounted into a steel enclosure. The encosure has a removable front cover that provides easy access and arf LED viewing hole on the top of the cover. PR-1/PR-2/PR-3 are epcxy encapsulated multi-voltage relays. They are singe-pole dbuble-throw relays that use a red LED as a visible indicatori of rea coil energization. PR-3 is identical to PR-2, except t has an extra pair of wires for redundant power input. Model EQLR-i is am epcxy encapsulated, single-pole single-throw, nor-nal1v Opel reay that can be used as an end of line device in fire alarm sysrs ns, e.g to supervise power supplies. Agency Listings MEA approved LISTED Multi-Voltage Conventional Relay Specifications Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24VAC, 115 VAC, 230 VAC (R-1 OT/R-141) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-201/R-241) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OT/R-201: 2.51 x 3.351-V x 1.2"H R-14T/R-24T: 101x3.35Wx 1.2"H Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7A Specifications: R-10E/R-14E/R-20E/R-24E Operating Voltage 18-35 VDC, 18-35 VAC, 115 VAC, 230 VAC Operating Current 20 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-10EJR-14E) 40 mA DC max. @24 VDC, 24 VAC, 115 VAC, 230 VAC (R-20EJR-24E) Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10% - 93% non-condensing Dimensions R-1 OE/R-20E: 5.11 x 3.75W x 2.51-1 R-14EJR-24E: 11 Tx 5.31N x 2.51-1 Contact Ratings 24 VDC: 7 A with LJR = 5 mS 12O VAC: 10A 120 VAC: 1/6 HP 230 VAC: 7 A Operating Voltage 18-35 VDC, 18-35 VAC, 120 VAC Operating Current 15 mA DC max. @24 VDC, 24 VAC, 120 VAC Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8 minimum Dimensions 0.871-I x 2.01'W x 1.421) Contact Ratings 24 VDC: 7 A with L/R = 5 mS 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A resistive 30 VDC: 10 A resistive Specifications: PR-2/PR-3 Operating Voltage 10 to 40 VDC Operating Current 30 mA DC max. Operating Temperature -40°F to 158°F (-40°C to 70°C) Humidity Range 10- 93% RH Wire Length 8" minimum Dimensions 0.91 'H x 1.65W x 1.221) Contact Ratings 120 VAC: 10 A max. (resistive load) 120 VAC: 7 A max. (0.35 PF) 250 VAC: 10 A max. (resistive load) 30 VDC: 10 A max. (resistive load) Operating Voltage 9 to 40 VDC Operating Current 20 mA DC max. Operating Temperature -22°F to 140°F (-30°C to 60°C) Humidity Range 10-93% RH Wire Length 8" minimum Contact Ratings 120 VAC: 0.5 A max. (resistive load) 30VDC: 3 A max. (resistive load) - PR-1 EOLR-1 PR-3 R-10E & R-20E Enclosure PR-2 R-10T R-141 R-14E & R-24E Enclosure 102007 System Sensor. SYSTEM 3825 Ohio Avenue. St. Charles, IL 60174 Product spe6cations subject to change without noSce.Sisitsystemserrsoncomhor s .$ SEItISOR Phone: 800-SENSOR2 . Fax: 630-377-6495 C=rentproainforflOOUOn,r=ludrngthte=nonofthrsdarash=1. A05-0372'005 .3/07' #1782 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0173 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models R-I0T/R-20T, R-14T/R-24T, and R-I0E/R-20E, R-I4EIR-24E Multi-Voltage Relay. Suitable for use in air handling spaces. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24 VDC/(+); 24 VAC; 115 VAC, 60 Hz, 230 VAC, 60Hz. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7300-1209:233 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM SENSOR® (Indoor Selectable- Output Strobes and Horn Strobes for / . Ceiling Applications, System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any application requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes inc:ude a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of applicatior: requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING LISTED APPROVED S5512 FM approved except 7125-1653:0504 S4011 for ALERT models 7135-1653:0503 3057363 AVDS868-02 • 12/0112017• Page 3 L-Series Specifications ttIII(°LI'1 ILI IIL° l]•1°iII LI!L'III- General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 120124 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V(24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V(12 V nominal) or 16.5 to 33 V (24V nominal) Input Terminal Wire Gauge 12 to 18AWG Ceiling-Mount Dimensions (including lens) 6.8' diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions (SBBCRL, SBBCWL) 6.90 diameter x 340 high (175 mm diameter x 86 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd. AVOS86-02 • 12/01/2017 • Page 2 UL Current Draw Data III 1rr1l.ThI(iiY:IiEi Candela 8-17.5 Volts DC 16-33 Volts DC FWR Candela 15 87 41 60 Range 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 8-17.5 Volts 16-33 Volts Sound Pattern dB DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 MS), Ceiling Horn Strobe, Candela I LI'LI DC Input 15cd 30cd 15cd 30cd 75cd 95cd llscd 150cd 177cd Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 -- 184 229 257 3.lK Temporal Low 103 163 54 88 143 155 185 212 252 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 11 5c 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data Horn Strobe Output (dBA) 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS868.02 • 12/01/2017 • Page 3 2.47 (62.7 mm) 1.37' (34.8 mm) 6,83" A— (173 rr 6.92' dbam (175. (64 mm) L-Series Dimensions A054500 A0546-00 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box -01 1.01 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Description Ceiling Horn Strobes PC2RL 2-Wire, Horn Strobe, Red PC2WL 2-Wire, Horn Strobe, White PC4RL 4-Wire, Horn Strobe, Red PC4WL 4-Wire, Horn Strobe, White 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box Ceiling Strobes SCRL Strobe, Red SUWL Strobe, Wnite SCWL-CLR-ALERT Strobe, White, ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceilina Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". SYSTEM ©2017 System Sensor. 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change without notice. Visit systemse000r corn _.$ SENSOR' Phone: 800-SENSOR2 • Fax- 630-377-6495 for current product information, including the latest version of this data sheet AVOS868-02 • 12/01/2017 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0503 Page 1 of 2 CATEGORY: 7135--AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: System Sensor Indoor 2-wire and *4..wire Models: HWL, HRL, HGWL and HGRL Horns; CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall Horn Strobes; PC2RL, PC2WL, *PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WaliTrim Rings: *TR2 and *TR2W Ceilinglrim Rings: *TRC2 and *TRC2W Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc TO This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v" operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MPI20KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sissonhoneyweII.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: TR2 and TR2W CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct JViP operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division