Loading...
HomeMy WebLinkAbout2501 EL CAMINO REAL; 200; FPC2019-0072; Permit(Lcitwof PERMIT REPORT Carlsbad Print Date: 01/13/2022 Permit No: FPC2019-0072 Job Address: 2501 EL CAMINO REAL, # 200, CARLSBAD, CA 92008-1215 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563023500 Track #: Applied: 03/18/2019 Valuation: $150,000.00 Lot #: Issued: 04/02/2019 Occupancy Group: Project #: Finaled Close Out: 04/22/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: REGAL CINEMAS MALL ENTRY -FIRE ALARM TI Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS PC BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov frc2-o9 -007-Z Johnson Controls Fire Protection, LP * 3568 Ruffin Road, South / San Diego, CA 92123-2597 Johnson Tele (858) 633-9100 Control Fax: (858) 633-9101 wvvwjci.com Fire Detection and Alarm System Product Submittal Project: Regal Cinemas Mall Entry The Shoppes at Carlsbad 2501 El Camino Real Suite 200 Carlsbad, CA For any questions regarding this submittal, please contact Douglas Daniels, 858-633-9123 or douqIas.daniels(äjci.com 3/13/2019 REV.#: 0 PROJECT Johnson Controls Fro Protection, LP 3E8 Ruffin Road,. South Jt / San Diego CA 92123-2597 Johnson 'r Tele (85) 633-9100 C rtr I F9X: (858) 633-91 Cl I I I wtiiw iri ('(m Fire Detection anc Alarm Syst:3m Products Qty Model No. Description C.S.F.M. No, 1 SPSWL Speaker Strcbe 73201653:10535 Business Information - V 3/13/2019 / rrlt t It l• i1111111118,I1I,I1x tttltllll,tII,IllIl tIuIIIIII tl III till lll II + ItIf 4 f SYSTEM $ SENSOR Indoor Selectable- Output Speaker Strobes and Dual Voltage Evacuation Speakers for Wall Applications System Sensor L-Series selectable output speaker strobes and dual-voltage evacuation speakers can reduce ground faults and enable faster installation with lower current draw and modern aesthetics. Features Plug-in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests wiring continuity before installation No extension ring required Field selectable candela settings on wall units: 15,3075,95,110,135,185 Automatic selection of 12- or 24-volt operation at 15 and 30 candela Rotary switch simplifies field selection of speaker voltage (25 and 70.7 Vrms) and power settings (1/4,1/2, 1 and 2 watts) Speakers offer high fidelity and high volume sound output 520 Hz +1- 10% square wave tone capable with compatible FACP Compatible with System Sensor synchronization protocol Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper-resistant construction Updated modern aesthetics Aaencv Listincis SIGNALING APPROVED LISTED S4048 FM approved except 7320-1653:0505 for ALERT models 3057493 The System Sensor L-Series of speakers and speaker strobes reduce costly ground faults using a pug-in design and universal mounting plate that allow the installer to pre-wire mounting plates, dress the wires, and confirm wiring conTinuity before plugging in the speakers. In addition, a protective p astic cover prevents nicked wires by covering exposed speaker components. These devices also enable faster installations by providing instant feedback to ensure that wiring is properly connected, rotary switches to select voltage and power settings. and 7 field-selectable candela settings for wall speaker strobes. The low total harmonic distortion of :ie speaker offers high fidelity sound output while still offering high 'io:ume sound output for use in high ambient noise applications. System Sensor L-Series makes installation easy Attach a universal mounting plate o a 4 x 4 x 21/8 inch back box. Flush-mount applications do not require an extension ring. Connect the notification appliance circuit or speaker wiring to the terminals on the mounting plate. Attach the speaker or speaker strcbe to the mounting plate by inserting the product tabs into the mounting plate grooves. Hinge the device into position to lock the product pins into the mounting plate terminals. The device will temporarily hold in place with a catch until it is secured with a captured mounting screw. AVDS867-02 • 03/2312018 • Page 1 L-Series Speaker and Speaker Strobe Specifications General L-Series speaker and speaker strobes shall mount to a 4 x 4 x 21/e-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate. Also, L-Series speaker strobes, when used with the Sync.CircuitTM Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 dolts; 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32°F and 120°F from a regulated DC, or full-wave rectified, unfiltered power supply. Wall- mount speaker strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, 185. Speaker The speaker shall be aSp System Sensor L-Series model ______ dual-voltage transformer speaker capable of operating at 25.0 or 70.7 nominal Vrms. It should be listed to UL 1480 and shall be approved for fire protective service. The speaker shall have a frequency range of 400 to 4,000 Hz and shall have an operating temperature between 32°F and 120°F. The speaker shall have power taps and voltage that are selected by rotary switches. - Speaker Strobe combination The speaker strobe shall be a System Senscr L-Series model listed to UL1480 and UL 1971 and be approved for fire protective signaling systems. The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch, and shall have a frequency range of 400 to 4,000 Hz. The speaker shall have power taps that are selected by rotary switch. The strobe shall comply with the NFPA 72 requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflebtor system. Synchronization Module The module shall be a System Sensor Sync.Oircuit model MDLS listed to UL 464 and shall be approved for fire protective service. The module shall synchronize strobes at 1 Hz. The modue shall mount to a 411/16 x 411/16 x 21/6-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Dimensions, Wall-Mount Length Width Depth SPL Speaker 6.5 in, 165 mm 5 in, 127 mm 0.97 in,23 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 3.2 in, 82 mm SPSL Speaker/Strobe (including lens and speaker) 6.5 in, 165 mm 5.0 in, 127 mm 2.3 in, 58 mm With Surface Mount Back Box 6.6 in, 168 mm 5.1 in, 130 mm 4.5 in, 116 mm *When using 12AWG, 14 AWG, or adding extra wires inthe box, a deeper box or extension ring is recommended. Operating Voltage with MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Frequency Range 400 to 4000 Hz3 Power 1/4,½,1,2watts Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. Strobe products will operate at 12 V nominal only for 15 and 30 cd 520 Hz +1- 10% square wave tone capable with compatible FACP. AVDS867-02 • 03/23/2018 • Page 2 UL Current Draw Data 8 to 17.5 Volts 16 to 33 Volts Candela DC DC FWR 15 88 43 60 30 143 63 83 75 N/A 107: 136 95 N/A 12t 155 110 N/A 148 179 135 N/A kl72 209 185 N/A 222 257 1/4 W 1/2W 1W 2W UL Reverberant (dBA@loft) 77 80 83 86 ULAnechoic(dBA@loft) 77 80 83 86 1/4 W ½W 1W 2W UL Reverberant (dBA@loft) 79 82 85 88 ULAnechoic(dBA@loft) 79 82 85 88 L-Series Dimensions 0.97 l- -I- l 1.63" (41.66 mm) (24.64 mm) (1 A0555-01 2.3 (58 MM 1.39' (35.31 ml 1.63 (41.66 mm) A0556-01 Wall-Mount Speaker Wall-Mount Speaker Strobe AVDS867-02 • 03/23/2018 • Page 3 Surface Mounting O523-01 Wall-Mount Speaker Strobe with SBBSPRLJ SBBSPWL Surface Mount Back Box L-Series Ordering information White Red Description SPWL SPRL Speaker cnly SPSWL SPSRL Speaker Strobe SPSWL-P SPSRL-P Plain Speaker Strobe SPSWL-ALERT - Speaker Strobe, Amber Lens SPSWL-CLR-ALERT - Speaker Strobe Clear Lens - SPSRL-SP Speaker Strobe, Fuego Accessories White Red Description RFPW RFP 7 in x 9.5 in Retrofit Plate SBBSPWL SBBSPRL Surface Mount Back Box for Speakers and Speake S: robes TR-2W TR-2 Wall Mount Trim Ring Notes: ' All -P models have a plain housing (no FIRE" marking on the cover) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©28SystSensor. 5iLSc,I? Phone: 800-SENSOR2 • Fax: 630-377-6495 Products dicabunssublecttschange.eidtautnotice.'tdtsystsmserrsor.com tot caters product irrorrsation, includingthe latest vorsort of this data sheet. www.systemsensor.com AvDS867-02 • O&2/2O1& CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-1653:0505 Page 1 of 2 CATEGORY: 7320 -- SPEAKERS LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Email: Vladimir. Kireyevhoneywell.com DESIGN: System Sensor Indoor Models: SPRL and SPWL Wall Speakers; SPCRL and SPCWL Ceiling Speakers; SPSRL, SPSWL, SPSRL-P, SPSRL-SP, SPSWL-P, SPSWL-ALERT and SPSWL-CLR-ALERT Wall Speaker Stobes; SPSCRL, SPSCWL, SPSCWL-P, SPSCWL-SP and SPSCWL-CLR-ALERT Ceiling Speaker Strobes. Wall Bezel Parts: BZSPR-P, BZSPR-AL, BZSPR-EV, BZSPR-AG, BZSPR-PG, BZSPR-F and BZSPR-SP, BZSPW-P, BZSPW-AL, BZSPW-EV, BZSPW-AG, BZSPW-PG, BZSPW-F and BZSPW-SP, Ceiling Bezel Parts: BZSPRC-P, BZSPRC-AL, BZSPRC-EV, BZSPRC-AG, BZSPRC-PG, BZSPRC-F and BZSPRC-SP, BZSPWC-P, BZSPWC-AL, BZSPWC-EV, BZSPWC-AG, BZSPWC-PG, BZSPWC-F and BZSPWC-SP, WallTrim Rings for Speaker Strobes: TR2 and TR2W Ceilinglrim Rings for Speaker Strobes: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: SBBSPRL and SBBSPWL, Ceiling Surface Mounted Back Boxes: SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. 02-27-17 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7320-1653:0505 Page 2of2 RATING: 25 or 70.7 VAC, 1/4,1/2,1, 2 Watt outputs. - Regulated 12 VDC and 24 VDC/FWR is for 2-wire strobe portion. INSTALLATION: In accordance with Iiste's printed installation instructions, NFPA 72, applicable codes & ordinances and in a mainer acceptable to the authority having jurisdiction. MARKING: Listees name, model number electrical rating, and UL label. APPROVAL: Listed as speakers and speaker-strobes when used with separately listed compatible fire alarm control units. Suitable for indoor use, dry and damp environments. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. )2-27-1 gt / sT1 This listing is based upon tehnicaJ data submitted by the applicant. CSFM Fire Engineering stsft has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used 4o verify correct ftVl operational requirements or irstallaton crteria. Refer to listee's data sheet, installation instructcns and/cr other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division #" Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Contractor's License Detail for License # 986047 Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2019 This license is current and active. All information below should be reviewed. Classifications dO - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Bonding Information Contractors Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History 1 Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for TIMOTHY PAUL ROSTEN in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2017 Expire Date: 10/01/2018 Workers' Compensation History Other Personnel listed on this license (current or disassociated) are listed on other licenses. Personnel listed on this license (current or disassociated) are listed on other licenses. 3/13/2019 REV.#: 0 PROJECT #: 480-XXXXXX-XX / X)000000(X controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South Sar Diego, CA 92123-2597 Ye/e: (858) 633-9100 Fax: (858) 633-9101 www.jci. corn JOHNSON CONTROLS WARRANTY WARRANTY & DAMAGES: Johnson Controls hereby warranties for one (1) yea? from the date of beneficia use or twelve (12) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, includirg any implied warranty of merchantability of fitess for a particular purpose. Johnson Controls shall not be liable for any direct, incidental or consequential loss cf damage to the purchaser or user of this equipment: arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by Johnson Controls in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: f - 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED JOHNSON CONTROLS HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST 4 3/13/2019 REV.#: 0 PROJECT#: 480:-XXXXXX-XX/XXXXXXXXX /