Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 160; AS070071; PermitCity of Carlsbad Sprinkler Permit Permit No: AS070071 2525 EL CAMINO Job Address: REAL Permit Type: SPRINK Parcel No: 1563020900 Lot #: 0 Reference No.: Status: ISSUED Applied 3/20/2007 Approved: 3/20/2007 Issued: 3/20/2007 Inspector: Project Title: SPENCERS GIFTS STE 160 TI FIRE SPRINKLER PLAN CHECK @ INSPECTION Applicant: BRADSHAW ENGINEERING CORP 8645 ARGENT ST SANTEE CA 619-448-4300 Owner: PLAZA CAMINO REAL CIO WESTFIELD CORP INC 11601 WILSHIRE BLVD LOS ANGELES CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 Pendent A60TODq1 Bulletin 110 Rev.S H Re able Model G Automatic Sprinklers Spray Upright, Spray Pendent And Conventional Product Description The Reliable Model G Automatic Sprinkler utilizes the center strut solder in compression principle of construction. The fusible alloy is captured in the cylinder of the solder capsule by a stainless steel ball. When the fusible alloy melts, the ball moves into the cylinder allowing the cylinder to fall away from the sprinkler. When this happens, the lever is released to spring free from the sprinkler so that all of the operating parts clear from the waterway allowing the deflector to distribute the discharging water. Except for the parts in the cylinder as mentioned above, the sprinkler components are made from copper based alloys for maximum corrosion protection. Lead plated, wax coated or wax over lead plated sprinklers are available for specially severe environments. Chrome plated sprinklers are available for decorative purposes. All sprinklers are individually hydrostatically tested. All sprinklers are identified as to their fusing point by markings that appear on several of the operating parts and by an identifying color that appears on the frame. Sprinkler Types Standard Upright - This deflector configuration is normally used with exposed piping installations. Water is distributed laterally and downward in a wide pattern approximating a hemisphere which is completely and uniformly filled with water in the form of small drops or spray. Standard Pendent - This deflector configuration is normally used where the space above the piping is limited or where a concealed piping installation is employed. The discharge characteristics of the standard pendent are virtually identical to the standard upright as described above. Large and Small Orifice—By varying the orifice size, a large or small orifice sprinkler is created that will distribute as much as 40% more water or 65% less water than the normal ½" (15mm) orifice sprinkler. Conventional—This deflector configuration is used primarily in those countries where the LPC installation rules have precedence. The sprinkler is designed to distribute a portion of its water discharge upward against the ceiling with the balance downward. It may be installed in either the upright or the pendent position. Sprinklers with conventional deflectors are available with orifice sizes corresponding to light, ordinary and extra—high hazard installations. Upright Small Orifice Upright Conventional Application and Installation Standard sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice sizes, temperature ratings, deflector styles and sprinkler spacings are in accordance with the latest published standards of the National Fire Protection Association or the approving authority having jurisdiction. The sprinklers must be installed with the Reliable Model D Sprinkler Wrench. Any other type of wrench may damage the sprinkler. The approvals or listings of Reliable Automatic Sprinklers by major approving organizations are shown in the tabulatec list provided on the back of this bulletin. *Patent No. 4,440234 The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 Technical Data "K Factor Sprinkler Identification Sprinkler Number(SIN) SSU SSP Sprinkler Type US Metric Height Approvals Standard-Upright (SSU) and Pendent (SSP) Deflectors Marked to Indicate Position 5.62 81.0 2 V8" (73 mm) 1 2, 3, 4, 5, 6, 7 R1025 R1015 )" (15 mm) Standard Orifice with ,1" NPT (RX) Thread X6 (11 mm) Small Orifice with,)" NPT (R,J) Thread 4.24 61.0 2V8" (73 mm) 1,3,7 R1023 R1013 (10 mm) Small Orifice with Y2" NPT (RX) Thread 2.82 40.6 2 V8' (73 mm) 1, 2, 3, 7 R1021 R1011 i' (8 mm) Small Orifice with )" NPT (RX) Thread 1.98 28.5 2 V8' (73 mm) 1, 3, 7 R1022 R1012 1%2 (20 mm) Large Orifice with Y2" NPT (R)) Thread 7.96 114.7 2 V8" (73 mm) 1, 2, 3, 7 R1026 R1016 %2 (20 mm) Large Orifice with " NPT (R)Thread 20 mm XHH with 20 mm Thread 8.20 8.20 118.2 118.2 2 1%6 (75 mm) 75.4 mm 1, 2, 3, 7 4, 5, 6 R1027 R1027 R1017 R1017 10mm XLH with 10mm Thread 4.10 1 59.1 73 mm 4, 5, 6 R1024 R1014 Conventional—Installed in Upright or Pendent Position 4.10 59.1 73 mm 5 R1074 10mm XLH with 10mm Thread 15mm Standard Orifice with (RX) Thread 5.62 81.0 73 mm 4, 5,6 R1075 20mm XHH with (R%) Thread 8.20 118.2 75.4 mm 4,5 R1077 TemDerature Ratinas Maximum Sprinkler Ambient Rating Temperature Frame (1) OF C OF °C Classification Color Ordinary 135 57 100 38 Black Ordinary 165 74 100 38 Uncolored Intermediate 212 100 150 66 White High 286 141 225 107 Blue Frame color does not apply to painted or plated sprinklers -Use sprinkler rating as identified on operating parts. Finishes(l) Maintenance Model G Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove any sprinkler that has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Use only the Model D Sprinkler Wrench for sprinkler removal and installation. Any other type of wrench may damage the sprinkler. Standard Finishes Bronze —All Temperature Ratings Chrome 2) —All Temperature Ratings White —All Temperature Ratings Only _Frame _and _Deflector _are _Painted Special Application Finishes Bright Brass Plated —Only frame, deflector and cap are plated. 135°F (57°C), 165°F (74°C), 212°F (100°C) Temp. Rating. Black Plated —Only frame, deflector and cap are plated. All Temp. Ratings. Polyester Coated (2) —Only frame and deflector are coated. Lead Plated —165°F (74°C), 212°F (100°C) and 286°F (141°C) Temp. Ratings. Wax-Coated (3) —165°F (74°C) Clear Wax, 212°F (100°c) Brown Wax. Wax-Coated Over Lead Plated (3) —165°F (74°C) Clear Wax, 212°F (100°c) Brown Wax. Other colors and finishes are available. Consult factory for details. UL listed and NYC MEA Approved only. 212°F (100°C) brown wax may be used on 286°F (141°C) sprinklers when maximum ambient temperatures do not exceed 150°F (66°C). UL Listed, FM Approved, NYC MEA 258-93-E. Approval Organizations Underwriters Laboratories, Inc. Factory Mutual Research Corporation Underwriters' Laboratories of Canada Loss Prevention Council Pleniere Assemblee VdS SchadenverhUtung N.Y.C. BS&A No. 587-75—SA or N.Y.C. MEA 258-93-E Ordering Information Specify Model G Deflector Upright Pendent Conventional Nominal Orifice Inlet Thread Temperature Rating Finish The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices www.reliablesprinkler.com Internet Address Revision lines indicate updated or new data. EG. Printed in U.S.A. 11/04 P/N 9999970005 THERE ARE NO PLANS ASSOCIATED WITH, THIS PERMIT