Loading...
HomeMy WebLinkAbout951 PALOMAR AIRPORT RD; ; FPC2019-0185; PermitPERMIT REPORT Cd_isbad aity of Print Date: 01/19/2022 Permit No: FPC2019-0185 Job Address: 951 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-1110 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2110403600 Track #: Applied: 08/05/2019 Valuation: $716,254.00 Lot #: Issued: 08/21/2019 Occupancy Group: Project #: Finaled Close Out: 02/05/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: COSTCO -EXISTING COOLER SPRINKLER TI (25 HEADS) Applicant: FPContractor: LINDLEY FIRE PROTECTION LINDLEY FIRE PROTECTION JAVIER MEJIA 1109 N ARMANDO ST 2220 E VIA BURTON ANAHEIM, CA 92806-2609 ANAHEIM, CA 92806-1221 (714) 535-5761 (714) 984-4150 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov " ' r''ri *HYDRAULIC DESIGN INFORMATION SHEET* Name:COSTCO Wholesale Date:10-19-18 Address:951 Palomar Airport Rd., Carlsbad, CA 92011 Location#:#462 Building:POS Freezer/Cooler Remote #:1 Calculated By:A. Wiseman Drawing #:FP3.0 Construction: Combustible X Non-Combustible SYSTEM DESIGN: As per NFPA 13 2016; Class I-Ill commodity on single or double row racks (no solid shelves), with minimum 4' aisles, 20' high non-encapsulated storage. 11.2 K-factor sprinklers allow for the use of high temperature curve per 12.6.9. Area of Sprinkler Operation:.43 Density - 2000 SF Area Per Sprinkler:90.0 SF Avg. (100 Max.) Inside Hose Allowance:100 GPM Ouside Hose Allowance:400 GPM Overhead C Factor: 120 Underground C Factor:— 140 SYSTEM TYPE: X WET; - DRY; _DELUGE; PRE-ACTION SPRINKLER TYPE: Standard Response Dry Pendent ELO Sprinkler Head, K=1 1.2, 205 Degrees SIN#VK545 CALCULATION SUMMARY: Total Demand @ Source: 1648.1 GPM (iii 55.6 Total Demand @ Base of Riser: 1148.1 GPM (2i 42.9 WATER SUPPLY: Date: 9/24/18 Water flow test performed by Carlsbad Fire Dept. Static: 70 PSI Residual: 47 PSI @ 4060 GPM Raw flow data reduced Safety Factor of 10% (7 PSI) as per AHJ and owner requirements. Static: 63.0 PSI Residual: 40.0 PSI @ 4060 GPM FPC20I9-0185 951 PALOMAR AIRPORT RD COSTCO - EXISTING COOLER SPRINKLER TI (25 HEADS) 2110403600 8/5/2019 FPC20I9-0185 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) A07 30.5 - - - - 15.5 - - - A08 30.5 - - - - 13.9 - - - A09 30.5 - - - - 13.7 - - - A10 30.5 - - - - 17.0 - - - All 30.5 - - - - 17.0 - - - Al2 30.5 - - - - 16.2 - - - A13 30.5 - - - - 16.1 - - - A14 30.5 - - - - 17.0 - - - A15 30.5 - - - - 17.0 - - - A16 30.5 - - - - 17.0 - - - A17 30.5 - - - - 17.0 - - - A18 30.5 - - - - 16.3 - - - A19 30.5 - - - - 16.1 - - - A20 30.5 - - - - 14.0 - - - A21 30.5 - - - - 14.0 - - - A22 30.5 - - - - 15.5 - - - A23 30.5 - - - - 15.6 - - - A24 30.5 - - - - 13.8 - - - A25 30.5 - - - - 14.0 - - - B01 30.0 - - - - 18.3 - - - B02 30.0 - - - - 18.3 - - - B03 30.0 - - - - 18.4 - - - B04 30.0 - - - - 16.3 - - - B05 30.0 - - - - 16.2 - - - B06 30.0 - - - - 18.4 - - - B07 30.0 - - - - 18.4 - - - 308 30.0 - - - - 16.1 - - - 309 30.0 - - - - 16.1 - - - B10 30.0 - - - - 18.9 - - - Bll 30.0 - - - - 19.0 - - - B12 30.0 - - - - 19.0 - - - B13 30.0 - - - - 19.0 - - - B14 30.0 - - - - 18.9 - - - B15 30.0 - - - - 19.0 - - - B16 30.0 - - - - 18.9 - - - B17 30.0 - - - - 19.0 - - - B18 30.0 - - - - 19.0 - - - B19 30.0 - - - - 19.0 - - - B20 30.0 - - - - 16.3 - - - B21 30.0 - - - - 16.5 - - - B22 30.0 - - - - 18.4 - - - 323 30.0 - - - - 18.6 - - - B24 30.0 - - - - 16.2 - - - 325 30.0 - - - - 16.4 - - - 1 28.0 - - - - 26.8 - - - 1A 30.0 - - - - 25.6 - - - 2 28.0 - - - - 19.9 - - - 2A 30.0 - - - - 19.3 - - - 3 28.0 - - - - 26.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 97 1.0 - - - - 44.3 - - - 98 -3.0 - - - - 46.6 - - - 99 -3.0 - - - - 51.6 - - - 100 -3.0 HOSE STREAM 53.2 400.0 101 -3.0 - - - - 54.3 - - - 102 -3.0 SOURCE 55.6 1648.1 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -47.2 1.380 FL 8.25 PF 1.9 DP13 22.2 11.2 17.7 47.2 10.1 120 FTG E PE -3.6 A13 30.5 0.0 16.1 0.0 0.167 TL 11.25 PV Pipe: 14 -48.3 1.380 PL 8.25 PF 2.0 DP14 22.2 11.2 18.6 48.3 10.4 120 FTG S PE -3.6 A14 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 15 -48.3 1.380 PL 8.25 PF 2.0 DP15 22.2 11.2 18.6 48.3 10.4 120 FTG E PS -3.6 A15 30.5 0.0 17.0 0.0 0.175 TL 11.25 PV Pipe: 16 -48.2 1.380 PL 8.25 PF 2.0 DP16 22.5 11.2 18.5 48.2 10.3 120 FTG E PE -3.5 A16 30.5 0.0 17.0 0.0 0.174 TL 11.25 PV Pipe: 17 -48.2 1.380 PL 8.25 PF 2.0 DP17 22.5 11.2 18.5 48.2 10.3 120 FTG E PE -3.5 A17 30.5 0.0 17.0 0.0 0.174 TL 11.25 PV Pipe: 18 -47.3 1.380 PL 8.25 PF 1.9 DP18 22.5 11.2 17.9 47.3 10.2 120 FTG E PE -3.5 A18 30.5 0.0 16.3 0.0 0.168 TL 11.25 PV Pipe: 19 -47.2 1.380 PL 8.25 PP 1.9 DP19 22.5 11.2 17.7 47.2 10.1 120 FTG E FE -3.5 A19 30.5 0.0 16.1 0.0 0.167 TL 11.25 PV Pipe: 20 -44.5 1.380 PL 8.25 PP 1.7 DF20 22.5 11.2 15.8 44.5 9.6 120 FTG E PE -3.5 A20 30.5 0.0 14.0 0.0 0.150 TL 11.25 PV Pipe: 21 -44.5 1.380 PL 8.25 PP 1.7 DP21 22.5 11.2 15.8 44.5 9.5 120 FTG E FE -3.5 A21 30.5 0.0 14.0 0.0 0.150 TL 11.25 PV Pipe: 22 -46.4 1.380 PL 8.25 PP 1.8 DP22 22.5 11.2 17.2 46.4 10.0 120 FTG E PS -3.5 A22 30.5 0.0 15.5 0.0 0.162 TL 11.25 PV Pipe: 23 -46.6 1.380 FL 8.25 PF 1.8 DP23 22.5 11.2 17.3 46.6 10.0 120 FTG E PS -3.5 A23 30.5 0.0 15.6 0.0 0.163 TL 11.25 PV Pipe: 24 -44.2 1.380 PL 8.25 PF 1.7 DP24 22.5 11.2 15.6 44.2 9.5 120 FTG E PE -3.5 A24 30.5 0.0 13.8 0.0 0.149 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 37 -47.4 1.380 PL 6.00 PF 2.5 Al2 30.5 0.0 16.2 0.0 10.2 120 FTG ET PE 0.2 B12 30.0 0.0 19.0 0.0 0.169 IL 15.00 PV Pipe: 38 -47.2 1.380 PL 7.25 PF 2.7 A13 30.5 0.0 16.1 0.0 10.1 120 FTG ST PS 0.2 B13 30.0 0.0 19.0 0.0 0.167 TL 16.25 PV Pipe: 39 -48.3 1.380 PL 1.00 PF 1.7 A14 30.5 0.0 17.0 0.0 10.4 120 FTG ST PE 0.2 B14 30.0 0.0 18.9 0.0 0.175 TL 10.00 PV Pipe: 40 -48.3 1.380 FL 1.00 PF 1.7 A15 30.5 0.0 17.0 0.0 10.4 120 FTG El PE 0.2 B15 30.0 0.0 19.0 0.0 0.175 TL 10.00 PV Pipe: 41 -48.2 1.380 PL 1.00 PF 1.7 A16 30.5 0.0 17.0 0.0 10.3 120 FTG ET FE 0.2 316 30.0 0.0 18.9 0.0 0.174 TL 10.00 PV Pipe: 42 -48.2 1.380 PL 1.00 PF 1.7 A17 30.5 0.0 17.0 0.0 10.3 120 FTG ET PE 0.2 317 30.0 0.0 19.0 0.0 0.174 TL 10.00 PV Pipe: 43 -47.3 1.380 PL 5.50 PF 2.4 A18 30.5 0.0 16.3 0.0 10.2 120 FTG ET PE 0.2 318 30.0 0.0 19.0 0.0 0.168 TL 14.50 PV Pipe: 44 -47.2 1.380 PL 6.75 PF 2.6 A19 30.5 0.0 16.1 0.0 10.1 120 FTG ST PS 0.2 319 30.0 0.0 19.0 0.0 0.167 TL 15.75 PV Pipe: 45 -44.5 1.380 PL 4.50 PF 2.0 A20 30.5 0.0 14.0 0.0 9.6 120 FIG ST PE 0.2 B20 30.0 0.0 16.3 0.0 0.150 TL 13.50 PV Pipe: 46 -44.5 1.380 FL 6.50 PF 2.3 A21 30.5 0.0 14.0 0.0 9.5 120 FTG ST PE 0.2 321 30.0 0.0 16.5 0.0 0.150 TL 15.50 PV Pipe: 47 -46.4 1.380 FL 7.50 PF 2.7 A22 30.5 0.0 15.5 0.0 10.0 120 FIG ST PS 0.2 322 30.0 0.0 18.4 0.0 0.162 TL 16.50 PV Pipe: 48 -46.6 1.380 PL 7.50 PF 2.7 A23 30.5 0.0 15.6 0.0 10.0 120 FTG El PS 0.2 B23 30.0 0.0 18.6 0.0 0.163 IL 16.50 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) OIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 61 72.1 2.635 PL 2.00 PF 0.3 11 28.0 0.0 25.9 0.0 4.2 120 FTG T PE -0.9 hA 30.0 0.0 24.7 0.0 0.016 TL 18.47 PV Pipe: 62 -72.1 2.635 PL 2.00 PF 0.3 12 28.0 0.0 19.9 0.0 4.2 120 FTG T PE -0.9 12A 30.0 0.0 19.3 0.0 0.016 TL 18.47 PV Pipe: 63 114.1 2.635 PL 2.00 PP 0.7 13 28.0 0.0 25.8 0.0 6.7 120 FTG T PE -0.9 13A 30.0 0.0 24.2 0.0 0.037 TL 18.47 PV Pipe: 64 63.3 2.635 FL 2.00 PF 0.2 14 28.0 0.0 19.9 0.0 3.7 120 FTG T FE -0.9 14A 30.0 0.0 18.8 0.0 0.012 TL 18.47 PV Pipe: 65 85.7 2.635 PL 2.00 PF 0.4 15 28.0 0.0 25.7 0.0 5.0 120 FTG T PE -0.9 15A 30.0 0.0 24.4 0.0 0.022 TL 18.47 PV Pipe: 66 10.9 2.635 PL 2.00 PF 0.0 16 28.0 0.0 19.9 0.0 0.6 120 FTG T FE -0.9 16A 30.0 0.0 19.0 0.0 0.000 TL 18.47 PV Pipe: 67 85.2 2.635 FL 2.00 PF 0.4 17 28.0 0.0 25.7 0.0 5.0 120 FTG T FE -0.9 17A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 68 9.3 2.635 PL 2.00 PF 0.0 18 28.0 0.0 19.9 0.0 0.5 120 FTG T FE -0.9 18A 30.0 0.0 19.0 0.0 0.000 TL 18.47 PV Pipe: 69 70.7 2.635 PL 2.00 PF 0.3 19 28.0 0.0 25.6 0.0 4.2 120 FTG T FE -0.9 19A 30.0 0.0 24.5 0.0 0.015 TL 18.47 PV Pipe: 70 -70.7 2.635 FL 2.00 PF 0.3 20 28.0 0.0 19.9 0.0 4.2 120 FTG T FE -0.9 20A 30.0 0.0 19.3 0.0 0.015 TL 18.47 PV Pipe: 71 85.0 2.635 FL 2.00 PF 0.4 21 28.0 0.0 25.6 0.0 5.0 120 FTG T FE -0.9 21A 30.0 0.0 24.4 0.0 0.021 TL 18.47 PV Pipe: 72 11.6 2.635 FL 2.00 PF 0.0 22 28.0 0.0 19.9 0.0 0.7 120 FTG T FE -0.9 22A 30.0 0.0 19.0 0.0 0.001 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HM(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 85 -38.0 6.357 PL 8.00 PF 0.0 18 28.0 0.0 19.9 0.0 0.4 120 FTG ---- FE 0.0 20 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 86 32.7 6.357 PL 8.00 PF 0.0 20 28.0 0.0 19.9 0.0 0.3 120 FTG ---- FE 0.0 22 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 87 21.1 6.357 PL 8.00 PP 0.0 22 28.0 0.0 19.9 0.0 0.2 120 FTG ---- FE 0.0 24 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 88 9.7 6.357 PL 8.00 SF 0.0 24 28.0 0.0 19.9 0.0 0.1 120 FTG ---- PE 0.0 26 28.0 0.0 19.9 0.0 0.000 TL 8.00 PV Pipe: 89 1070.3 6.357 FL 8.00 PF 0.3 1 28.0 0.0 26.8 0.0 10.8 120 FTG ---- PE 0.0 3 28.0 0.0 26.5 0.0 0.032 TL 8.00 PV Pipe: 90 994.1 6.357 PL 8.00 PP 0.2 3 28.0 0.0 26.5 0.0 10.0 120 FTG ---- FE 0.0 5 28.0 0.0 26.3 0.0 0.028 TL 8.00 PV Pipe: 91 897.7 6.357 FL 8.00 PF 0.2 5 28.0 0.0 26.3 0.0 9.1 120 FTG ---- FE 0.0 7 28.0 0.0 26.1 0.0 0.023 TL 8.00 PV Pipe: 92 781.8 6.357 PL 8.00 SF 0.1 7 28.0 0.0 26.1 0.0 7.9 120 FTG ---- FE 0.0 9 28.0 0.0 26.0 0.0 0.018 TL 8.00 PV Pipe: 93 682.5 6.357 PL 8.00 PP 0.1 9 28.0 0.0 26.0 0.0 6.9 120 FTG ---- PE 0.0 11 28.0 0.0 25.9 0.0 0.014 TL 8.00 PV Pipe: 94 610.4 6.357 FL 8.00 PP 0.1 11 28.0 0.0 25.9 0.0 6.2 120 FTG ---- PE 0.0 13 28.0 0.0 25.8 0.0 0.011 TL 8.00 PV Pipe: 95 496.3 6.357 PL 8.00 PF 0.1 13 28.0 0.0 25.8 0.0 5.0 120 FTG ---- PE 0.0 15 28.0 0.0 25.7 0.0 0.008 TL 8.00 PV Pipe: 96 410.6 6.357 FL 8.00 PF 0.0 15 28.0 0.0 25.7 0.0 4.2 120 FTG ---- FE 0.0 17 28.0 0.0 25.7 0.0 0.005 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 109 26.8 2.635 PL 24.00 PF 0.1 B20 30.0 0.0 16.3 0.0 1.6 120 FTG ---- PE 0.0 B05 30.0 0.0 16.2 0.0 0.003 TL 24.00 PV Pipe: 110 -50.7 2.635 PL 8.00 PF 0.1 B05 30.0 0.0 16.2 0.0 3.0 120 FTG ---- PE 0.0 B04 30.0 0.0 16.3 0.0 0.008 TL 8.00 PV Pipe: 111 -95.4 2.635 PL 67.50 PF 2.2 B04 30.0 0.0 16.3 0.0 5.6 120 FTG T PE 0.0 8A 30.0 0.0 18.5 0.0 0.026 TL 83.97 PV Pipe: 112 99.3 2.635 FL 195.50 PF 6.0 9A 30.0 0.0 24.6 0.0 5.8 120 FTG T PE 0.0 B23 30.0 0.0 18.6 0.0 0.028 TL 211.97 PV Pipe: 113 52.8 2.635 PL 17.00 PF 0.1 B23 30.0 0.0 18.6 0.0 3.1 120 FTG ---- PE 0.0 B22 30.0 0.0 18.4 0.0 0.009 TL 17.00 PV Pipe: 114 6.4 2.635 FL 24.00 PF 0.0 B22 30.0 0.0 18.4 0.0 0.4 120 FTG ---- PE 0.0 B07 30.0 0.0 18.4 0.0 0.000 TL 24.00 PV Pipe: 115 -40.1 2.635 PL 8.00 PF 0.0 B07 30.0 0.0 18.4 0.0 2.4 120 FTG ---- PE 0.0 B06 30.0 0.0 18.4 0.0 0.005 TL 8.00 PV Pipe: 116 -40.1 2.635 FL 67.50 PF 0.4 B06 30.0 0.0 18.4 0.0 2.4 120 FTG T PE 0.0 bA 30.0 0.0 18.9 0.0 0.005 TL 83.97 PV Pipe: 117 72.1 2.635 PL 312.00 PF 5.4 hA 30.0 0.0 24.7 0.0 4.2 120 FTG 2T FE 0.0 12A 30.0 0.0 19.3 0.0 0.016 TL 344.95 PV Pipe: 118 114.1 2.635 PL 195.50 PF 7.8 13A 30.0 0.0 24.2 0.0 6.7 120 FTG T FE 0.0 B25 30.0 0.0 16.4 0.0 0.037 TL 211.97 PV Pipe: 119 69.6 2.635 PL 17.00 PF 0.3 B25 30.0 0.0 16.4 0.0 4.1 120 FTG ---- PE 0.0 B24 30.0 0.0 16.2 0.0 0.015 TL 17.00 PV Pipe: 120 25.4 2.635 PL 24.00 PF 0.1 B24 30.0 0.0 16.2 0.0 1.5 120 FTG ---- FE 0.0 B09 30.0 0.0 16.1 0.0 0.002 TL 24.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 16 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HN(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 133 84.9 2.635 PL 236.50 PF 5.4 23A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 B17 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 134 36.7 2.635 PL 8.00 PF 0.0 B17 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 B16 30.0 0.0 18.9 0.0 0.005 TL 8.00 PV Pipe: 135 -11.4 2.635 PL 67.50 PF 0.0 316 30.0 0.0 18.9 0.0 0.7 120 FTG T PE 0.0 24A 30.0 0.0 19.0 0.0 0.001 TL 83.97 PV Pipe: 136 84.8 2.635 PL 236.50 PF 5.4 25A 30.0 0.0 24.4 0.0 5.0 120 FTG T PE 0.0 B19 30.0 0.0 19.0 0.0 0.021 TL 252.97 PV Pipe: 137 37.6 2.635 PL 8.00 PF 0.0 319 30.0 0.0 19.0 0.0 2.2 120 FTG ---- PE 0.0 B18 30.0 0.0 19.0 0.0 0.005 TL 8.00 PV Pipe: 138 -9.7 2.635 PL 67.50 PF 0.0 B18 30.0 0.0 19.0 0.0 0.6 120 FTG T PE 0.0 26A 30.0 0.0 19.0 0.0 0.000 TL 83.97 PV Pipe: 139 -1148.1 6.357 PL 80.00 PF 4.1 1 28.0 0.0 26.8 0.0 11.6 120 FTG 3L PE 0.0 95 28.0 0.0 30.9 0.0 0.036 TL 113.95 PV Pipe: 140 -1148.1 8.249 PL 25.00 PF 1.2 95 28.0 0.0 30.9 0.0 6.9 120 FTG TBA PR 10.8 96 3.0 H.S. 42.9 100.0 0.010 TL 116.61 PV Pipe: 141 -1248.1 8.249 PL 2.00 PF 0.5 96 3.0 H.S. 42.9 100.0 7.5 120 FTG T PE 0.9 97 1.0 0.0 44.3 0.0 0.012 TL 43.11 PV Pipe: 305 -1248.1 8.510 PL 50.00 PF 0.6 97 1.0 0.0 44.3 0.0 7.0 140 FTG LG PE 1.7 98 -3.0 0.0 46.6 0.0 0.008 TL 80.91 PV Pipe: 306 FIXED PRESSURE LOSS DEVICE 99 -3.0 0.0 51.6 0.0 5.0 psi, 1248.1 gpm 98 -3.0 0.0 46.6 0.0 Pipe: 307 -1248.1 10.520 PL 425.00 PF 1.5 99 -3.0 0.0 51.6 0.0 4.6 140 FTG T2L PR 0.0 100 -3.0 H.S. 53.2 400.0 0.003 TL 563.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 18 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A U N Eli Tee LngEii ChkViv BfyViv GatViv AimChk DPViv Tee 1.380 3.00 6.00 2.00 7.00 6.00 1.00 10.00 10.00 6.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 20 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#0061.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #1/POS WATER SUPPLY CURVE 72+ 66+ *\ 60+ \ I \ Ix \ 54+ I \\ I \ \ P 48+ \ R \\ E I \ S 5 42+ \ U * <-40.0 psi 8 4060 gpm R I Flow Test Point E I 36+ P S I I 30+ 24+ 18+ 12+ LEGEND X = Required Water Supply I 55.60 psi 8 1648.1 gpm 6+ I 0 = Available Water Supply I 58.66 psi 8 1648.1 gpm 0++-+---+----+-----+------+ --------+ --------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) .t. . ,.., : • *HYDRAULIC DESIGN INFORMATION SHEET* Name:COSTCO Wholesale Date: 10-19-18 Address: 951 Palomar Airport Rd., Carlsbad, CA 92011 Location#:#462 Building:Produce Cooler Remote #:2 Calculated By:A. Wiseman Drawing #:FP3.0 Construction: Combustible X Non-Combustible SYSTEM DESIGN: As per NFPA 13 2016; Class I-Il commodity on single row racks (no solid shelves), with minimum 4' aisles, 20' high non-encapsulated storage. 11.2 K-factor sprinklers allow for the use of high temperature curve per 12.6.9. Area of Sprinkler Operation: .3 8 5 Density - Entire Area Area Per Sprinkler:93.0 SF Avg. (100 Max.) Inside Hose Allowance:100 GPM Ouside Hose Allowance:400 GPM Overhead C Factor: 120 Underground C Factor:— 140 SYSTEM TYPE: X WET; - DRY; ____DELUGE; PRE-ACTION SPRINKLER TYPE: Standard Response Dry Pendent ELO Sprinkler Head, K1 1.2, 205 Degrees SIN#VK545 CALCULATION SUMMARY: Total Demand @ Source: 1592.7 GPM (2i 53.8 Total Demand @ Base of Riser: 1092.7 GPM 41.5 WATER SUPPLY: Date: 9/24/18 Water flow test performed by Carlsbad Fire Dept. Static: 70 PSI Residual: 47 PSI @ 4060 GPM Raw flow data reduced Safety Factor of 10% (7 PSI) as per AHJ and owner requirements. Static: 63.0 PSI Residual: 40.0 PSI @ 4060 GPM SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) A30 30.5 - - - - 8.5 - - - A31 30.5 - - - - 12.9 - - - A32 30.5 - - - - 10.5 - - - A33 30.5 - - - - 10.9 - - - A34 30.5 - - - - 10.7 - - - A35 30.5 - - - - 11.4 - - - A36 30.5 - - - - 11.7 - - - A37 30.5 - - - - 11.6 - - - A38 30.5 - - - - 11.3 - - - A39 30.5 - - - - 10.8 - - - A40 30.5 - - - - 11.0 - - - A41 30.5 - - - - 10.8 - - - A42 30.5 - - - - 10.6 - - - A43 30.5 - - - - 10.4 - - - A44 30.5 - - - - 11.4 - - - A45 30.5 - - - 11.6 - - - A46 30.5 - - - - 11.5 - - - A47 30.5 - - - - 11.2 - - - A48 30.5 - - - - 10.9 - - - A49 30.5 - - - - 11.1 - - - A50 30.5 - - - - 11.1 - - - A51 30.5 - - - - 10.6 - - - A52 30.5 - - - - 10.4 - - - B26 30.0 - - - - 13.5 - - - B27 30.0 - - - - 13.5 - - - B28 30.0 - - - - 13.4 - - - B29 30.0 - - - - 13.3 - - - B30 30.0 - - - - 13.0 - - - B31 30.0 - - - - 13.1 - - - B32 30.0 - - - - 12.7 - - - B33 30.0 - - - - 12.5 - - B34 30.0 - - - - 12.5 - - - B35 30.0 - - - - 13.5 - - - B36 30.0 - - - - 13.5 - - - B37 30.0 - - - - 13.4 - - - B38 30.0 - - - 13.3 - - - B39 30.0 - - - - 12.9 - - - B40 30.0 - - - - 13.0 - - - B41 30.0 - - - - 12.6 - - - B42 30.0 - - - 12.4 - - - B43 30.0 - - - - 12.4 - - B44 30.0 - - - - 13.5 - - - B45 30.0 - - - - 13.6 - - - B46 30.0 - - - - 13.4 - - - B47 30.0 - - - - 13.4 - - - B48 30.0 - - - - 13.0 - - - B49 30.0 - - - - 13.0 - - - B50 30.0 - - - - 12.6 - - - B51 30.0 - - - - 12.5 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 25 28.0 - - - - 24.8 - - - 25A 30.0 - - - - 23.6 - - - 26 28.0 - - - - 17.0 - - - 26A 30.0 - - - - 16.5 - - - 38 28.0 - - - - 16.1 - - - 38A 30.0 - - - - 13.9 - - - 39 28.0 - - - - 16.1 - - - 39A 30.0 - - - - 13.4 - - - 40 28.0 - - - - 16.1 - - - 40A 30.0 - - - - 13.9 - - - 41 28.0 - - - - 16.1 - - 41A 30.0 - - - - 13.3 - - - 42 28.0 - - - - 16.1 - - - 42A 30.0 - - - - 13.9 - - - 43 28.0 - - - - 16.2 - - 43A 30.0 - - - - 13.4 - - 95 28.0 - - - - 29.6 - - - 96 3.0 HOSE STREAM 41.6 100.0 97 1.0 - - - - 42.9 - - - 98 -3.0 - - - - 45.2 - - - 99 -3.0 - - - - 50.2 - - - 100 -3.0 HOSE STREAM 51.6 400.0 101 -3.0 - - - - 52.6 - - - 102 -3.0 SOURCE 53.9 1592.7 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUN. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -41.0 1.380 PL 8.25 PP 1.5 0P38 22.2 11.2 13.4 41.0 8.8 120 FTG E PE -3.6 A38 30.5 0.0 11.3 0.0 0.129 TL 11.25 PV Pipe: 14 -40.4 1.380 PL 8.25 PP 1.4 0P39 22.2 11.2 13.0 40.4 8.7 120 FTG B PH -3.6 A39 30.5 0.0 10.8 0.0 0.125 TL 11.25 PV Pipe: 15 -40.6 1.380 PL 8.25 PP 1.4 DF40 22.2 11.2 13.1 40.6 8.7 120 FTG E PE -3.6 A40 30.5 0.0 11.0 0.0 0.127 TL 11.25 PV Pipe: 16 -40.2 1.380 PL 8.25 PF 1.4 DP41 22.5 11.2 12.9 40.2 8.6 120 FTG E PE -3.5 A41 30.5 0.0 10.8 0.0 0.124 TL 11.25 PV Pipe: 17 -39.9 1.380 FL 8.25 PF 1.4 DP42 22.5 11.2 12.7 39.9 8.6 120 FTG E PE -3.5 A42 30.5 0.0 10.6 0.0 0.123 TL 11.25 PV Pipe: 18 -39.6 1.380 PL 8.25 PF 1.4 DP43 22.5 11.2 12.5 39.6 8.5 120 FTG E PE -3.5 A43 30.5 0.0 10.4 0.0 0.121 TL 11.25 PV Pipe: 19 -41.0 1.380 PL 8.25 PP 1.5 DP44 22.5 11.2 13.4 41.0 8.8 120 FTG E FE -3.5 A44 30.5 0.0 11.4 0.0 0.129 TL 11.25 PV Pipe: 20 -41.3 1.380 FL 8.25 PF 1.5 DP45 22.5 11.2 13.6 41.3 8.9 120 FTG E FE -3.5 A45 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 21 -41.2 1.380 PL 8.25 PP 1.5 DP46 22.5 11.2 13.5 41.2 8.8 120 FTG E PE -3.5 A46 30.5 0.0 11.5 0.0 0.130 TL 11.25 PV Pipe: 22 -40.8 1.380 PL 8.25 PP 1.4 DP47 22.5 11.2 13.3 40.8 8.7 120 FTG E FE -3.5 A47 30.5 0.0 11.2 0.0 0.128 TL 11.25 PV Pipe: 23 -40.3 1.380 FL 8.25 PF 1.4 0P48 22.5 11.2 12.9 40.3 8.6 120 FTG E PE -3.5 A48 30.5 0.0 10.9 0.0 0.125 TL 11.25 PV Pipe: 24 -40.7 1.380 FL 8.25 PF 1.4 DF49 22.5 11.2 13.2 40.7 8.7 120 FTG E FE -3.5 A49 30.5 0.0 11.1 0.0 0.127 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 8 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 35 -41.2 1.380 PL 5.00 PF 1.8 A35 30.5 0.0 11.4 0.0 8.8 120 FTG ET FE 0.2 B35 30.0 0.0 13.5 0.0 0.130 TL 14.00 PV Pipe: 36 -41.6 1.380 PL 3.00 PF 1.6 A36 30.5 0.0 11.7 0.0 8.9 120 FTG ET PE 0.2 B36 30.0 0.0 13.5 0.0 0.133 TL 12.00 PV Pipe: 37 -41.4 1.380 PL 3.00 PF 1.6 A37 30.5 0.0 11.6 0.0 8.9 120 FTG ET PE 0.2 B37 30.0 0.0 13.4 0.0 0.131 TL 12.00 PV Pipe: 38 -41.0 1.380 PL 5.00 PF 1.8 A38 30.5 0.0 11.3 0.0 8.8 120 FTG ET PE 0.2 B38 30.0 0.0 13.3 0.0 0.129 TL 14.00 PV Pipe: 39 -40.4 1.380 PL 6.00 PF 1.9 A39 30.5 0.0 10.8 0.0 8.7 120 FTG ET FE 0.2 B39 30.0 0.0 12.9 0.0 0.125 TL 15.00 PV Pipe: 40 -40.6 1.380 PL 5.00 PF 1.8 A40 30.5 0.0 11.0 0.0 8.7 120 FTG ET PE 0.2 B40 30.0 0.0 13.0 0.0 0.127 TL 14.00 PV Pipe: 41 -40.2 1.380 PL 4.00 PF 1.6 A41 30.5 0.0 10.8 0.0 8.6 120 FTG ET PE 0.2 B41 30.0 0.0 12.6 0.0 0.124 TL 13.00 PV Pipe: 42 -39.9 1.380 PL 4.00 PF 1.6 A42 30.5 0.0 10.6 0.0 8.6 120 FTG ET PE 0.2 B42 30.0 0.0 12.4 0.0 0.123 TL 13.00 PV Pipe: 43 -39.6 1.380 PL 6.00 PF 1.8 A43 30.5 0.0 10.4 0.0 8.5 120 FTG ET FE 0.2 B43 30.0 0.0 12.4 0.0 0.121 TL 15.00 PV Pipe: 44 -41.0 1.380 PL 6.00 PF 1.9 A44 30.5 0.0 11.4 0.0 8.8 120 FTG ET PE 0.2 B44 30.0 0.0 13.5 0.0 0.129 TL 15.00 PV Pipe: 45 -41.3 1.380 PL 4.00 PF 1.7 A45 30.5 0.0 11.6 0.0 8.9 120 FTG ET PE 0.2 B45 30.0 0.0 13.6 0.0 0.131 TL 13.00 PV Pipe: 46 -41.2 1.380 PL 4.00 PF 1.7 A46 30.5 0.0 11.5 0.0 8.8 120 FTG ET PE 0.2 B46 30.0 0.0 13.4 0.0 0.130 TL 13.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 10 DATE: 10/19/2018 C:\PROGRAN FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 57 84.8 2.635 PL 2.00 PF 0.4 7 28.0 0.0 25.3 0.0 5.0 120 FTG T FE -0.9 7A 30.0 0.0 24.1 0.0 0.021 TL 18.47 PV Pipe: 58 -84.8 2.635 PL 2.00 PF 0.4 8 28.0 0.0 17.2 0.0 5.0 120 FTG T FE -0.9 8A 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 59 84.1 2.635 PL 2.00 PF 0.4 9 28.0 0.0 25.2 0.0 4.9 120 FTG T PE -0.9 9A 30.0 0.0 23.9 0.0 0.021 TL 18.47 PV Pipe: 60 -84.1 2.635 PL 2.00 PF 0.4 10 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 iDA 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 61 83.5 2.635 FL 2.00 PF 0.4 11 28.0 0.0 25.1 0.0 4.9 120 FTG T PE -0.9 hA 30.0 0.0 23.8 0.0 0.021 TL 18.47 PV Pipe: 62 -83.5 2.635 FL 2.00 PF 0.4 12 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 12A 30.0 0.0 16.7 0.0 0.021 TL 18.47 PV Pipe: 63 83.0 2.635 FL 2.00 PF 0.4 13 28.0 0.0 25.0 0.0 4.9 120 FTG T PE -0.9 13A 30.0 0.0 23.7 0.0 0.020 TL 18.47 PV Pipe: 64 -83.0 2.635 PL 2.00 PF 0.4 14 28.0 0.0 17.2 0.0 4.9 120 FTG T FE -0.9 14A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV Pipe: 65 82.7 2.635 PL 2.00 PF 0.4 15 28.0 0.0 24.9 0.0 4.9 120 FTG T FE -0.9 15A 30.0 0.0 23.7 0.0 0.020 TL 18.47 PV Pipe: 66 -82.7 2.635 PL 2.00 PF 0.4 16 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 16A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV Pipe: 67 82.5 2.635 FL 2.00 PF 0.4 17 28.0 0.0 24.9 0.0 4.9 120 FTG T PE -0.9 17A 30.0 0.0 23.6 0.0 0.020 TL 18.47 PV Pipe: 68 -82.5 2.635 FL 2.00 PF 0.4 18 28.0 0.0 17.2 0.0 4.9 120 FTG T PE -0.9 18A 30.0 0.0 16.7 0.0 0.020 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 12 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 76E 164.3 2.635 PL 2.00 PF 1.3 42 28.0 0.0 16.1 0.0 9.7 120 FTG T PE -0.9 42A 30.0 0.0 13.9 0.0 0.072 TL 18.47 PV Pipe: 76F 201.1 2.635 PL 2.00 PF 1.9 43 28.0 0.0 16.2 0.0 11.8 120 FTG T PE -0.9 43A 30.0 0.0 13.4 0.0 0.105 TL 18.47 PV Pipe: 77 -396.1 6.357 PL 8.00 PF 0.0 2 28.0 0.0 17.1 0.0 4.0 120 FTG ---- PE 0.0 4 28.0 0.0 17.2 0.0 0.005 TL 8.00 PV Pipe: 78 -309.1 6.357 PL 8.00 PP 0.0 4 28.0 0.0 17.2 0.0 3.1 120 FTG ---- PE 0.0 6 28.0 0.0 17.2 0.0 0.003 TL 8.00 PV Pipe: 79 -223.3 6.357 PL 8.00 PF 0.0 6 28.0 0.0 17.2 0.0 2.3 120 FTG ---- PE 0.0 8 28.0 0.0 17.2 0.0 0.002 TL 8.00 PV Pipe: 80 -138.5 6.357 PL 8.00 PF 0.0 8 28.0 0.0 17.2 0.0 1.4 120 FTG ---- PE 0.0 10 28.0 0.0 17.2 0.0 0.001 TL 8.00 PV Pipe: 81 -54.4 6.357 PL 8.00 PF 0.0 10 28.0 0.0 17.2 0.0 0.5 120 FTG ---- PE 0.0 12 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 82 29.1 6.357 PL 8.00 PF 0.0 12 28.0 0.0 17.2 0.0 0.3 120 FTG ---- PE 0.0 14 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 83 112.1 6.357 PL 8.00 PP 0.0 14 28.0 0.0 17.2 0.0 1.1 120 FTG ---- PE 0.0 16 28.0 0.0 17.2 0.0 0.000 TL 8.00 PV Pipe: 84 194.7 6.357 PL 8.00 PP 0.0 16 28.0 0.0 17.2 0.0 2.0 120 FTG ---- PE 0.0 18 28.0 0.0 17.2 0.0 0.001 TL 8.00 PV Pipe: 85 277.2 6.357 PL 8.00 PP 0.0 18 28.0 0.0 17.2 0.0 2.8 120 FTG ---- PE 0.0 20 28.0 0.0 17.2 0.0 0.003 TL 8.00 PV Pipe: 86 359.6 6.357 PL 8.00 PF 0.0 20 28.0 0.0 17.2 0.0 3.6 120 FTG ---- PE 0.0 22 28.0 0.0 17.1 0.0 0.004 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 14 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOE TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 99 165.9 6.357 PL 8.00 PF 0.0 21 28.0 0.0 24.8 0.0 1.7 120 FTG ---- PE 0.0 23 28.0 0.0 24.8 0.0 0.001 TL 8.00 PV Pipe: 100 83.1 6.357 PL 8.00 PP 0.0 23 28.0 0.0 24.8 0.0 0.8 120 FTG ---- FE 0.0 25 28.0 0.0 24.8 0.0 0.000 TL 8.00 PV Pipe: bOA 317.7 6.357 PL 8.00 PF 0.0 38 28.0 0.0 16.1 0.0 3.2 120 FTG ---- PE 0.0 39 28.0 0.0 16.1 0.0 0.003 TL 8.00 PV Pipe: 100B 123.1 6.357 PL 8.00 PP 0.0 39 28.0 0.0 16.1 0.0 1.2 120 FTG ---- FE 0.0 40 28.0 0.0 16.1 0.0 0.001 TL 8.00 PV Pipe: 100C -42.2 6.357 PL 8.00 PF 0.0 40 28.0 0.0 16.1 0.0 0.4 120 FTG ---- PE 0.0 41 28.0 0.0 16.1 0.0 0.000 TL 8.00 PV Pipe: 1000 -242.8 6.357 PL 8.00 PF 0.0 41 28.0 0.0 16.1 0.0 2.5 120 FTG ---- PE 0.0 42 28.0 0.0 16.1 0.0 0.002 TL 8.00 PV Pipe: 100E -407.0 6.357 PL 8.00 PF 0.0 42 28.0 0.0 16.1 0.0 4.1 120 FTG ---- PE 0.0 43 28.0 0.0 16.2 0.0 0.005 TL 8.00 PV Pipe: lOOP -608.1 6.357 PL 53.00 PP 0.8 43 28.0 0.0 16.2 0.0 6.1 120 FTG 2L PE 0.0 26 28.0 0.0 17.0 0.0 0.011 TL 75.63 PV Pipe: bOG -484.6 6.357 PL 110.00 PF 1.0 38 28.0 0.0 16.1 0.0 4.9 120 FTG 2L PE 0.0 2 28.0 0.0 17.1 0.0 0.007 TL 132.63 PV Pipe: 101 88.5 2.635 PL 312.00 PF 7.9 1A 30.0 0.0 24.6 0.0 5.2 120 FTG 2T PE 0.0 2A 30.0 0.0 16.7 0.0 0.023 TL 344.95 PV Pipe: 102 87.0 2.635 PL 312.00 PF 7.7 3A 30.0 0.0 24.4 0.0 5.1 120 FTG 2T PE 0.0 4A 30.0 0.0 16.7 0.0 0.022 TL 344.95 PV Pipe: 103 85.8 2.635 PL 312.00 PP 7.5 5A 30.0 0.0 24.2 0.0 5.0 120 FTG 2T PE 0.0 6A 30.0 0.0 16.7 0.0 0.022 TL 344.95 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 16 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 116 120.1 2.635 PL 3.00 PF 0.8 43A 30.0 0.0 13.4 0.0 7.1 120 FTG T PR 0.0 B50 30.0 0.0 12.6 0.0 0.040 TL 19.47 PV Pipe: 117 79.5 2.635 PL 7.00 PF 0.1 B50 30.0 0.0 12.6 0.0 4.7 120 FTG ---- PE 0.0 B51 30.0 0.0 12.5 0.0 0.019 TL 7.00 PV Pipe: 118 39.6 2.635 PL 7.00 PR 0.0 B51 30.0 0.0 12.5 0.0 2.3 120 FTG ---- PR 0.0 352 30.0 0.0 12.4 0.0 0.005 TL 7.00 PV Pipe: 119 -41.0 2.635 PL 8.00 PF 0.0 B44 30.0 0.0 13.5 0.0 2.4 120 FTG ---- FE 0.0 B45 30.0 0.0 13.6 0.0 0.006 TL 8.00 PV Pipe: 120 -82.3 2.635 PL 2.00 PR 0.4 B45 30.0 0.0 13.6 0.0 4.8 120 FTG T PE 0.0 42A 30.0 0.0 13.9 0.0 0.020 TL 18.47 PV Pipe: 121 81.9 2.635 PL 10.00 PF 0.5 42A 30.0 0.0 13.9 0.0 4.8 120 FTG T PE 0.0 B46 30.0 0.0 13.4 0.0 0.020 TL 26.47 PV Pipe: 122 40.8 2.635 PL 7.00 PF 0.0 B46 30.0 0.0 13.4 0.0 2.4 120 FTG ---- PE 0.0 B47 30.0 0.0 13.4 0.0 0.005 TL 7.00 PV Pipe: 123 -40.4 2.635 PL 8.00 PR 0.0 B39 30.0 0.0 12.9 0.0 2.4 120 FTG ---- PR 0.0 340 30.0 0.0 13.0 0.0 0.005 TL 8.00 PV Pipe: 124 -80.9 2.635 PL 2.00 PF 0.4 240 30.0 0.0 13.0 0.0 4.8 120 FTG T PE 0.0 41A 30.0 0.0 13.3 0.0 0.019 TL 18.47 PV Pipe: 125 119.7 2.635 PL 1.00 PR 0.7 41A 30.0 0.0 13.3 0.0 7.0 120 FTG T PR 0.0 B41 30.0 0.0 12.6 0.0 0.040 TL 17.47 PV Pipe: 126 79.5 2.635 FL 9.00 PR 0.2 B41 30.0 0.0 12.6 0.0 4.7 120 FTG ---- PR 0.0 B42 30.0 0.0 12.4 0.0 0.019 TL 9.00 PV Pipe: 127 39.6 2.635 PL 7.00 PF 0.0 B42 30.0 0.0 12.4 0.0 2.3 120 FTG ---- PR 0.0 B43 30.0 0.0 12.4 0.0 0.005 TL 7.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 18 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 2.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #2/Produce PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 138B 41.4 2.635 PL 8.00 PF 0.0 B28 30.0 0.0 13.4 0.0 2.4 120 FTG ---- PE 0.0 B29 30.0 0.0 13.3 0.0 0.006 TL 8.00 PV Pipe: 139 -1092.7 6.357 PL 80.00 PF 3.8 1 28.0 0.0 25.9 0.0 11.0 120 FTG 3L PE 0.0 95 28.0 0.0 29.6 0.0 0.033 TL 113.95 PV Pipe: 140 -1092.7 8.249 PL 25.00 PF 1.1 95 28.0 0.0 29.6 0.0 6.6 120 FTG TBA PE 10.8 96 3.0 H.S. 41.6 100.0 0.009 TL 116.61 PV Pipe: 141 -1192.7 8.249 PL 2.00 PF 0.5 96 3.0 H.S. 41.6 100.0 7.2 120 FTG T PE 0.9 97 1.0 0.0 42.9 0.0 0.011 TL 43.11 PV Pipe: 305 -1192.7 8.510 PL 50.00 PF 0.6 97 1.0 0.0 42.9 0.0 6.7 140 FTG LG PE 1.7 98 -3.0 0.0 45.2 0.0 0.007 TL 80.91 PV Pipe: 306 FIXED PRESSURE LOSS DEVICE 99 -3.0 0.0 50.2 0.0 5.0 psi, 1192.7 gpm 98 -3.0 0.0 45.2 0.0 Pipe: 307 -1192.7 10.520 PL 425.00 PF 1.4 99 -3.0 0.0 50.2 0.0 4.4 140 FTC T21, PE 0.0 100 -3.0 H.S. 51.6 400.0 0.003 TL 563.25 PV Pipe: 308 -1592.7 10.520 PL 160.00 PF 1.0 100 -3.0 H.S. 51.6 400.0 5.9 140 FTG T PE 0.0 101 -3.0 0.0 52.6 0.0 0.004 TL 244.30 PV Pipe: 309 -1592.7 10.520 PL 288.00 PF 1.2 101 -3.0 0.0 52.6 0.0 5.9 140 FTG ---- PE 0.0 102 -3.0 SRCE 53.9 (N/A) 0.004 TL 288.00 PV NOTES (HASS) (1) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38050722 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 80.0 70.0 G A 60.0 U G E 50.0 P R E S S U R E P 20.0 S i 10.0 0.0 -14.7 30.0 40.0 WATER SUPPLY ANALYSIS Static: 63.00 psi Resid: 40.00 psi Flow: 4060.0 gpm Me Cu 0> WH Cli H H t ID Cli N) ID N) C-) 0 C/, ci 'd I I—I z C) Z > i Cli tOZI Cr) C/) - OH Qtl n 31 I H Cllt Lic OCnI:-H - I- Cl10 $N Cfl > cn N) Z ti C/) H HCf) ati OCr) CD — Cl, Cl, co OD CZD /D 0) N) CD Ci)CD U rj N) ID FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ!D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 102 63.0 40.0 4060.0 58.9 1608.3 55.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 1608.3 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 500.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 1108.3 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 0P52 22.2 K=11.20 13.5 41.2 DP53 22.2 K=11.20 13.6 41.3 DP54 22.2 K=11.20 13.8 41.6 0P55 22.2 K=11.20 13.2 40.7 0P56 22.2 K=11.20 11.4 37.8 DP57 22.2 K=11.20 11.4 37.8 DP58 22.2 K=11.20 13.5 41.1 DP59 22.2 K=11.20 13.6 41.3 DP60 22.2 K=11.20 13.7 41.5 DP61 22.2 K=11.20 13.6 41.4 DP62 22.2 K=11.20 13.7 41.4 0P63 22.2 K=11.20 13.9 41.8 DP64 22.2 K=11.20 13.5 41.2 0P65 22.2 K=11.20 13.6 41.3 DP66 22.2 K=11.20 13.7 41.5 DP67 22.5 K=11.20 13.5 41.1 0P68 22.5 K=11.20 13.5 41.2 DP69 22.5 K=11.20 13.8 41.7 OP70 22.5 K=11.20 13.3 40.9 DP71 22.5 K=11.20 13.4 41.0 DP72 22.5 K=11.20 13.7 41.5 DP73 22.5 K=11.20 13.4 40.9 DP74 22.5 K=11.20 13.4 41.1 0P75 22.5 K=11.20 13.8 41.5 DP76 22.5 K=11.20 13.6 41.3 DP77 22.5 K=11.20 13.6 41.3 DP78 22.5 K=11.20 13.9 41.8 A52 30.5 - - - - 11.4 - - - A53 30.5 - - - - 11.5 - - - A54 30.5 - - - - 11.7 - - - A55 30.5 - - - - 11.1 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) B78 30.0 - - - - 13.0 - - - 1 28.0 - - - - 24.6 - - - 1A 30.0 - - - - 23.3 - - - 2 28.0 - - - - 15.5 - - - 2A 30.0 - - - - 15.1 - - - 3 28.0 - - - - 24.3 - - - 3A 30.0 - - - - 23.0 - - - 4 28.0 - - - - 15.6 - - - 4A 30.0 - - - - 15.1 - - - 5 28.0 - - - - 24.1 - - - 5A 30.0 - - - - 22.9 - - - 6 28.0 - - - - 15.6 - - - 6A 30.0 - - - - 15.2 - - - 7 28.0 - - - - 24.0 - - - 7A 30.0 - - - - 22.7 - - - 8 28.0 - - - - 15.6 - - - 8A 30.0 - - - - 15,2 - - - 9 28.0 - - - - 23.8 - - - 9A 30.0 - - - - 22.6 - - - 10 28.0 - - - - 15.6 - - - 10A 30.0 - - - - 15.2 - - - 11 28.0 - - - - 23.7 - - - 11A 30.0 - - - - 22.5 - - - 12 28.0 - - - - 15.7 - - - 12A 30.0 - - - - 15.2 - - - 13 28.0 - - - - 23.7 - - - 13A 30.0 - - - - 22.4 - - - 14 28.0 - - - - 15.7 - - - 14A 30.0 - - - - 15.2 - - - 15 28.0 - - - - 23.6 - - - 15A 30.0 - - - - 22.3 - - - 16 28.0 - - - - 15.7 - - - 16A 30.0 - - - - 15.2 - - - 17 28.0 - - - - 23.5 - - - 17A 30.0 - - - - 22.3 - - - 18 28.0 - - - - 15.6 - - - 18A 30.0 - - - - 15.2 - - - 19 28.0 - - - - 23.5 - - - 19A 30.0 - - - - 22.3 - - - 20 28.0 - - - 15.6 - - - 20A 30.0 - - - - 15.1 - - 21 28.0 - - - - 23.5 - - - 21A 30.0 - - - - 22.2 - - - 22 28.0 - - - - 15.6 - - - 22A 30.0 - - - - 15.1 - - - 23 28.0 - - - - 23.5 - - - 23A 30.0 - - - - 22.2 - - - 24 28.0 - - - - 15.6 - - - 24A 30.0 - - - - 15.1 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -41.2 1.380 PL 8.25 PF 1.5 DP52 22.2 11.2 13.5 41.2 8.8 120 FTG E FE -3.6 A52 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 2 -41.3 1.380 PL 8.25 PP 1.5 DP53 22.2 11.2 13.6 41.3 8.9 120 FTG E FE -3.6 A53 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 3 -41.6 1.380 PL 8.25 PF 1.5 DP54 22.2 11.2 13.8 41.6 8.9 120 FTG E PE -3.6 A54 30.5 0.0 11.7 0.0 0.132 TL 11.25 PV Pipe: 4 -40.7 1.380 PL 8.25 FE 1.4 DP55 22.2 11.2 13.2 40.7 8.7 120 FTG E FE -3.6 A55 30.5 0.0 11.1 0.0 0.127 TL 11.25 PV Pipe: 5 -37.8 1.380 PL 8.25 PP 1.2 DP56 22.2 11.2 11.4 37.8 8.1 120 FTG E PE -3.6 A56 30.5 0.0 9.1 0.0 0.111 TL 11.25 PV Pipe: 6 -37.8 1.380 PL 8.25 PF 1.2 DP57 22.2 11.2 11.4 37.8 8.1 120 FTG E PE -3.6 A56 30.5 0.0 9.1 0.0 0.111 TL 11.25 PV Pipe: 7 -41.1 1.380 PL 8.25 PF 1.5 DP58 22.2 11.2 13.5 41.1 8.8 120 FTG E PE -3.6 A58 30.5 0.0 11.4 0.0 0.130 TL 11.25 PV Pipe: 8 -41.3 1.380 PL 8.25 PF 1.5 DP59 22.2 11.2 13.6 41.3 8.9 120 FTG E FE -3.6 A59 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 9 -41.5 1.380 PL 8.25 PF 1.5 DP60 22.2 11.2 13.7 41.5 8.9 120 FTG S FE -3.6 A60 30.5 0.0 11.6 0.0 0.132 TL 11.25 PV Pipe: 10 -41.4 1.380 PL 8.25 PF 1.5 DP61 22.2 11.2 13.6 41.4 8.9 120 FTG E PE -3.6 A61 30.5 0.0 11.5 0.0 0.131 TL 11.25 PV Pipe: 11 -41.4 1.380 PL 8.25 PF 1.5 DP62 22.2 11.2 13.7 41.4 8.9 120 FTG E PS -3.6 A62 30.5 0.0 11.6 0.0 0.132 TL 11.25 PV Pipe: 12 -41.8 1.380 PL 8.25 FE 1.5 0P63 22.2 11.2 13.9 41.8 9.0 120 FTG E FE -3.6 A63 30.5 0.0 11.8 0.0 0.134 TL 11.25 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 25 -41.3 1.380 PL 8.25 PP 1.5 DP76 22.5 11.2 13.6 41.3 8.9 120 FTG E PE -3.5 A76 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 25A -41.3 1.380 PL 8.25 PF 1.5 0P77 22.5 11.2 13.6 41.3 8.9 120 FTG E PE -3.5 A77 30.5 0.0 11.6 0.0 0.131 TL 11.25 PV Pipe: 25B -41.8 1.380 PL 8.25 PP 1.5 DP78 22.5 11.2 13.9 41.8 9.0 120 FTG E PE -3.5 A78 30.5 0.0 12.0 0.0 0.134 TL 11.25 PV Pipe: 26 -41.2 1.610 PL 5.50 PP 1.1 A52 30.5 0.0 11.4 0.0 6.5 120 FTG ET PE 0.2 B52 30.0 0.0 12.7 0.0 0.061 TL 17.50 PV Pipe: 27 -41.3 1.610 PL 4.50 PP 1.0 A53 30.5 0.0 11.5 0.0 6.5 120 FTG ET PE 0.2 B53 30.0 0.0 12.7 0.0 0.062 TL 16.50 PV Pipe: 28 -41.6 1.610 PL 5.50 PF 1.1 A54 30.5 0.0 11.7 0.0 6.6 120 FTG ET PE 0.2 B54 30.0 0.0 13.0 0.0 0.063 TL 17.50 PV Pipe: 29 -40.7 1.610 PL 5.50 PP 1.1 A55 30.5 0.0 11.1 0.0 6.4 120 FTG ET PE 0.2 B55 30.0 0.0 12.3 0.0 0.060 TL 17.50 PV Pipe: 30 -75.6 1.610 PL 4.50 PP 3.1 A56 30.5 0.0 9.1 0.0 11.9 120 FTG ET PE 0.2 B56 30.0 0.0 12.4 0.0 0.189 TL 16.50 PV Pipe: 31 0.0 1.610 PL 6.00 PP 0.0 A57 30.5 0.0 12.9 0.0 0.0 120 FTG ET PE 0.2 B57 30.0 0.0 13.1 0.0 0.000 TL 18.00 PV Pipe: 32 -41.1 1.610 PL 4.00 PF 1.0 A58 30.5 0.0 11.4 0.0 6.5 120 FTG ET PH 0.2 B58 30.0 0.0 12.6 0.0 0.061 TL 16.00 PV Pipe: 33 -41.3 1.610 PL 3.00 PP 0.9 A59 30.5 0.0 11.5 0.0 6.5 120 FTG ET PE 0.2 B59 30.0 0.0 12.6 0.0 0.062 TL 15.00 PV Pipe: 34 -41.5 1.610 PL 5.00 PF 1.1 A60 30.5 0.0 11.6 0.0 6.5 120 FTG ET PH 0.2 B60 30.0 0.0 12.9 0.0 0.062 TL 17.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 9 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 47 -40.9 1.610 PL 4.00 PF 1.0 A73 30.5 0.0 11.3 0.0 6.5 120 FTG ET PE 0.2 373 30.0 0.0 12.5 0.0 0.061 TL 16.00 PV Pipe: 48 -41.1 1.610 PL 3.00 PF 0.9 A74 30.5 0.0 11.4 0.0 6.5 120 FTG ET PE 0.2 374 30.0 0.0 12.6 0.0 0.061 TL 15.00 PV Pipe: 49 -41.5 1.610 PL 3.00 PF 0.9 A75 30.5 0.0 11.8 0.0 6.5 120 FTG ET PE 0.2 B75 30.0 0.0 12.9 0.0 0.062 TL 15.00 PV Pipe: 50 -41.3 1.610 PL 1.00 PF 0.8 A76 30.5 0.0 11.6 0.0 6.5 120 FTG ET PE 0.2 376 30.0 0.0 12.6 0.0 0.062 TL 13.00 PV Pipe: 50A -41.3 1.610 PL 1.00 PF 0.8 A77 30.5 0.0 11.6 0.0 6.5 120 FTG ET PE 0.2 377 30.0 0.0 12.7 0.0 0.062 TL 13.00 PV Pipe: 50B -41.8 1.610 PL 1.00 PF 0.8 A78 30.5 0.0 12.0 0.0 6.6 120 FTG ET PE 0.2 B78 30.0 0.0 13.0 0.0 0.063 TL 13.00 PV Pipe: 51 90.0 2.635 PL 2.00 PF 0.4 1 28.0 0.0 24.6 0.0 5.3 120 FTG T PE -0.9 1A 30.0 0.0 23.3 0.0 0.024 TL 18.47 PV Pipe: 52 -90.0 2.635 PL 2.00 PF 0.4 2 28.0 0.0 15.5 0.0 5.3 120 FTG T PE -0.9 2A 30.0 0.0 15.1 0.0 0.024 TL 18.47 PV Pipe: 53 88.4 2.635 PL 2.00 PF 0.4 3 28.0 0.0 24.3 0.0 5.2 120 FTG T PE -0.9 3A 30.0 0.0 23.0 0.0 0.023 TL 18.47 PV Pipe: 54 -88.4 2.635 FL 2.00 PF 0.4 4 28.0 0.0 15.6 0.0 5.2 120 FTG T FE -0.9 4A 30.0 0.0 15.1 0.0 0.023 TL 18.47 PV Pipe: 55 87.1 2.635 PL 2.00 PF 0.4 5 28.0 0.0 24.1 0.0 5.1 120 FTG T PE -0.9 5A 30.0 0.0 22.9 0.0 0.022 TL 18.47 PV Pipe: 56 -87.1 2.635 FL 2.00 PF 0.4 6 28.0 0.0 15.6 0.0 5.1 120 FTG T PE -0.9 6A 30.0 0.0 15.2 0.0 0.022 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 11 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 69 83.5 2.635 PL 2.00 PF 0.4 19 28.0 0.0 23.5 0.0 4.9 120 FTG T PE -0.9 19A 30.0 0.0 22.3 0.0 0.021 TL 18.47 PV Pipe: 70 -83.5 2.635 PL 2.00 PF 0.4 20 28.0 0.0 15.6 0.0 4.9 120 FTG T PH -0.9 20A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe: 71 83.6 2.635 PL 2.00 PF 0.4 21 28.0 0.0 23.5 0.0 4.9 120 FTG T PH -0.9 21A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe: 72 -83.6 2.635 PL 2.00 PF 0.4 22 28.0 0.0 15.6 0.0 4.9 120 FTG T PH -0.9 22A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe: 73 83.7 2.635 PL 2.00 PF 0.4 23 28.0 0.0 23.5 00 4.9 120 FTG T PE -0.9 23A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe: 74 -83.7 2.635 PL 2.00 PF 0.4 24 28.0 0.0 15.6 0.0 4.9 120 FTG T PE -0.9 24A 30.0 0.0 15.1 0.0 0.021 TL 18.47 PV Pipe: 75 84.0 2.635 PL 2.00 PF 0.4 25 28.0 0.0 23.5 0.0 4.9 120 FTG T PE -0.9 25A 30.0 0.0 22.2 0.0 0.021 TL 18.47 PV Pipe: 76 -84.0 2.635 PL 2.00 PF 0.4 26 28.0 0.0 15.5 0.0 4.9 120 FTG T PH -0.9 26A 30.0 0.0 15.0 0.0 0.021 TL 18.47 PV Pipe: 76A 124.0 2.635 PL 2.00 PF 0.8 44 28.0 0.0 14.8 0.0 7.3 120 FTG T PH -0.9 44A 30.0 0.0 13.1 0.0 0.043 TL 18.47 PV Pipe: 76B 116.3 2.635 PL 2.00 PF 0.7 45 28.0 0.0 14.7 0.0 6.8 120 FTG T PE -0.9 45A 30.0 0.0 13.1 0.0 0.038 TL 18.47 PV Pipe: 76C 123.9 2.635 PL 2.00 PF 0.8 46 28.0 0.0 14.7 0.0 7.3 120 FTG T PE -0.9 46A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV Pipe: 76D 124.6 2.635 PL 2.00 PF 0.8 47 28.0 0.0 14.7 0.0 7.3 120 FTG T PE -0.9 47A 30.0 0.0 13.0 0.0 0.043 TL 18.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 13 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 84 134.7 6.357 PL 8.00 PP 0.0 16 28.0 0.0 15.7 0.0 1.4 120 FTG ---- PE 0.0 18 28.0 0.0 15.6 0.0 0.001 TL 8.00 PV Pipe: 85 218.4 6.357 PL 8.00 PP 0.0 18 28.0 0.0 15.6 0.0 2.2 120 FTG ---- PE 0.0 20 28.0 0.0 15.6 0.0 0.002 TL 8.00 PV Pipe: 86 301.9 6.357 PL 8.00 PF 0.0 20 28.0 0.0 15.6 0.0 3.1 120 FTG ---- PE 0.0 22 28.0 0.0 15.6 0.0 0.003 TL 8.00 PV Pipe: 87 385.5 6.357 PL 8.00 PP 0.0 22 28.0 0.0 15.6 0.0 3.9 120 FTG ---- PE 0.0 24 28.0 0.0 15.6 0.0 0.005 TL 8.00 PV Pipe: 88 469.2 6.357 PL 8.00 PF 0.1 24 28.0 0.0 15.6 0.0 4.7 120 FTG ---- PE 0.0 26 28.0 0.0 15.5 0.0 0.007 TL 8.00 PV Pipe: 89 1018.2 6.357 PL 8.00 PF 0.2 1 28.0 0.0 24.6 0.0 10.3 120 FTG ---- PE 0.0 3 28.0 0.0 24.3 0.0 0.029 TL 8.00 PV Pipe: 90 929.8 6.357 PL 8.00 PF 0.2 3 28.0 0.0 24.3 0.0 9.4 120 FTG ---- PE 0.0 5 28.0 0.0 24.1 0.0 0.024 TL 8.00 PV Pipe: 91 842.7 6.357 PL 8.00 PF 0.2 5 28.0 0.0 24.1 0.0 8.5 120 FTG ---- PE 0.0 7 28.0 0.0 24.0 0.0 0.020 TL 8.00 PV Pipe: 92 756.6 6.357 PL 8.00 PP 0.1 7 28.0 0.0 24.0 0.0 7.6 120 FTG ---- PE 0.0 9 28.0 0.0 23.8 0.0 0.017 TL 8.00 PV Pipe: 93 671.3 6.357 PL 8.00 PP 0.1 9 28.0 0.0 23.8 0.0 6.8 120 FTG ---- PS 0.0 11 28.0 0.0 23.7 0.0 0.013 TL 8.00 PV Pipe: 94 586.6 6.357 PL 8.00 PF 0.1 11 28.0 0.0 23.7 0.0 5.9 120 FTG ---- PE 0.0 13 28.0 0.0 23.7 0.0 0.010 TL 8.00 PV Pipe: 95 502.4 6.357 PL 8.00 PP 0.1 13 28.0 0.0 23.7 0.0 5.1 120 FTG ---- PS 0.0 15 28.0 0.0 23.6 0.0 0.008 TL 8.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 15 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Neat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 108 -428.8 6.357 PL 16.00 PF 0.1 51 28.0 0.0 14.7 0.0 4.3 120 FTG ---- PE 0.0 52 28.0 0.0 14.8 0.0 0.006 TL 16.00 PV Pipe: 120 -553.3 6.357 PL 55.00 PF 0.7 52 28.0 0.0 14.8 0.0 5.6 120 FTG 2L PE 0.0 26 28.0 0.0 15.5 0.0 0.009 TL 77.63 PV Pipe: 121 -555.0 6.357 PL 55.00 PF 0.7 44 28.0 0.0 14.8 0.0 5.6 120 FTG 2L PE 0.0 2 28.0 0.0 15.5 0.0 0.009 TL 77.63 PV Pipe: 122 90.0 2.635 PL 312.00 PF 8.2 1A 30.0 0.0 23.3 0.0 5.3 120 FTG 2T PE 0.0 2A 30.0 0.0 15.1 0.0 0.024 TL 344.95 PV Pipe: 123 88.4 2.635 PL 312.00 PP 7.9 3A 30.0 0.0 23.0 0.0 5.2 120 FTG 2T PE 0.0 4A 30.0 0.0 15.1 0.0 0.023 TL 344.95 PV Pipe: 124 87.1 2.635 PL 312.00 PF 7.7 5A 30.0 0.0 22.9 0.0 5.1 120 FTG 2T PE 0.0 6A 30.0 0.0 15.2 0.0 0.022 TL 344.95 PV Pipe: 125 86.1 2.635 PL 312.00 PP 7.5 7A 30.0 0.0 22.7 0.0 5.1 120 FTG 2T PE 0.0 8A 30.0 0.0 15.2 0.0 0.022 TL 344.95 PV Pipe: 126 85.3 2.635 PL 312.00 PP 7.4 9A 30.0 0.0 22.6 0.0 5.0 120 FTG 2T PE 0.0 10A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 127 84.7 2.635 PL 312.00 PF 7.3 hA 30.0 0.0 22.5 0.0 5.0 120 FTG 2T PE 0.0 12A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 128 84.2 2.635 PL 312.00 PP 7.2 13A 30.0 0.0 22.4 0.0 5.0 120 FTG 2T PE 0.0 14A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 129 83.8 2.635 PL 312.00 PP 7.2 15A 30.0 0.0 22.3 0.0 4.9 120 FTG 2T PE 0.0 16A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV Pipe: 130 83.6 2.635 PL 312.00 PF 7.1 17A 30.0 0.0 22.3 0.0 4.9 120 FTG 2T PE 0.0 18A 30.0 0.0 15.2 0.0 0.021 TL 344.95 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 17 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: 4462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 143 41.5 2.635 PL 1.00 PF 0.1 46A 30.0 0.0 13.0 0.0 2.4 120 FTG T PE 0.0 B60 30.0 0.0 12.9 0.0 0.006 TL 17.47 PV Pipe: 144 -41.4 2.635 PL 10.00 PF 0.1 B61 30.0 0.0 12.6 0.0 2.4 120 FTG ---- PE 0.0 362 30.0 0.0 12.6 0.0 0.006 TL 10.00 PV Pipe: 145 -82.8 2.635 PL 2.00 PP 0.4 B62 30.0 0.0 12.6 0.0 4.9 120 FTG T PE 0.0 47A 30.0 0.0 13.0 0.0 0.020 TL 18.47 PV Pipe: 146 41.8 2.635 PL 4.00 PP 0.1 47A 30.0 0.0 13.0 0.0 2.5 120 FTG T PE 0.0 B63 30.0 0.0 12.9 0.0 0.006 TL 20.47 PV Pipe: 147 -41.2 2.635 PL 7.00 PP 0.0 364 30.0 0.0 12.6 0.0 2.4 120 FTG ---- PE 0.0 B65 30.0 0.0 12.6 0.0 0.006 TL 7.00 PV Pipe: 148 -82.5 2.635 PL 3.00 PF 0.4 B65 30.0 0.0 12.6 0.0 4.9 120 FTG T PE 0.0 48A 30.0 0.0 13.0 0.0 0.020 TL 19.47 PV Pipe: 149 41.5 2.635 PL 1.00 PP 0.1 48A 30.0 0.0 13.0 0.0 2.4 120 FTG T PE 0.0 366 30.0 0.0 12.9 0.0 0.006 TL 17.47 PV Pipe: 150 -41.1 2.635 PL 7.00 PF 0.0 B67 30.0 0.0 12.5 0.0 2.4 120 FTG ---- PE 0.0 868 30.0 0.0 12.5 0.0 0.006 TL 7.00 PV Pipe: 151 -82.3 2.635 PL 6.50 PP 0.5 B68 30.0 0.0 12.5 0.0 4.8 120 FTG T PE 0.0 49A 30.0 0.0 13.0 0.0 0.020 TL 22.97 PV Pipe: 152 41.7 2.635 PL 1.00 PP 0.1 49A 30.0 0.0 13.0 0.0 2.5 120 FTG T PP 0.0 B69 30.0 0.0 12.9 0.0 0.006 TL 17.47 PV Pipe: 153 -40.9 2.635 PL 8.00 PP 0.0 370 30.0 0.0 12.5 0.0 2.4 120 FTG ---- PE 0.0 B71 30.0 0.0 12.5 0.0 0.006 TL 8.00 PV Pipe: 154 -81.9 2.635 PL 7.00 PP 0.5 871 30.0 0.0 12.5 0.0 4.8 120 FTG T PE 0.0 50A 30.0 0.0 13.0 0.0 0.020 TL 23.47 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 19 DATE: 10/19/2018 C:\PROGRAM FILES\HRS SYSTEMS\HASS88\#006 3.SDF JOB TITLE: #462 COSTCO - CARLSBAD, CA - REMOTE #3/Meat-Deli Cooler PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 307 -1208.2 10.520 PL 425.00 PP 1.4 99 -3.0 0.0 51.4 0.0 4.5 140 FTG T2L PE 0.0 100 -3.0 H.S. 52.8 400.0 0.003 TL 563.25 PV Pipe: 308 -1608.2 10.520 PL 160.00 PF 1.1 100 -3.0 H.S. 52.8 400.0 5.9 140 FTG T PE 0.0 101 -3.0 0.0 53.9 0.0 0.004 TL 244.30 PV Pipe: 309 -1608.3 10.520 PL 288.00 PP 1.3 101 -3.0 0.0 53.9 0.0 5.9 140 FTG ---- PE 0.0 102 -3.0 SRCE 55.2 (N/A) 0.004 TL 288.00 PV NOTES (HASS) Calculations were performed by the MASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38050722 granted by MRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.131 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 11.9 ft/sec at pipe 30. Available pressure at source node 102 under full flow conditions is 58.60 psi with a flow of 1659.68 gpm. PIPE FITTINGS TABLE MASS Pipe Table Name: standard.pip 80.0 70.0 C A 60.0 U C E 50.0 P R S S S U R E P 20.0 S ± 10.0 0.0 -14.7 30.0 40.0 WATER SUPPLY ANALYSIS Static: 63.00 psi Resid: 40.00 psi Flow: 4060.0 gpm O I-i.. -i h- L CD CO . N) C) CD NJ h- C) C) 0 Cr) I-i (l C)) Ei I I-I z Dill z Dii tO Dii Cr).. Dii -Cl) UZCJ) OH G)tl I H 11 1:J tic Ooflt.l H DilmO Dii Cli Z CJ) CD Cl) H 0i H C/) ct Dii I-I I Cl) UI)) CD - H- C)) 01/) CC) o F- CD H l-j CD CD C) I-Cl Cli Di C/)(D U IM N) 1-1 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source FIRE SPRINKLER MATERIAL DATA Prepared by: nrgfireconsulting.com 7511 Greenwood Ave N #600 Seattle, WA 98103 (206) 789-0165 Anjanette Wiseman, CET Fire Protection Designer Project: Costco #462 Carlsbad, CA Freshline - Cooler - Freezer Renovations 951 Palomar Airport Rd. Carlsbad, CA 92011 October 19, 2018 FPC20I9-0185 951 PALOMAR AIRPORT RD COSTCO - EXISTING COOLER SPRINKLER TI (25 HEADS) 2110403600 8/512019 FPC20I9-0185 SECTION 1 Wheatland Tube Hve SpvhMer Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers and contractors across the continent depend on us for steel fire sprinkler pipe and a number of proprietary products— always in stock and ready to deliver. 100% Compatibility We guarantee our steel pipe is 100% compatible with fire protection systems that use only steel pipe. Why risk incompatibility? Wheatland's complete line of steel sprinkler pipe makes design easy and brings you peace of mind. Accurate and Efficient Our products help you work safer and smarter—not harder. With our extensive in-house capabilities, we offer the shortest production cycle times in the industry, and we deliver to you accurately and on time, every time. Wheatland Tube has never warranted compatibility between its steel pipe products and CPVC products. Green and Sustainable Our steel fire sprinkler pipe contains recycled steel and provides decades of reliable service. At the end of its life, the steel may be almost fully recycled, supporting your green policies. Zekelman Industries Wheatland Tube is a division of Zekelman Industries, the largest independent manufacturer of steel hollow structural sections (HSS) and steel pipe in North America. We leverage our 100-plus years of pipe and tube manufacturing experience and expertise to produce 2 million tons of pipe and tube annually. Backed by Zekelman Industries, you can count on Wheatland for strength, innovation and service - bringing exceptional value to your business. ID up tc 7170 larger than Schedule 10 and 11% larger tha Schedule 40 i 'Y 'It thct a.)trsv hydv &_ cglvea~(ev Y/R- ~UJGF Wheatland's Mega-Flow is an engineered, light-wall steel sprinkler pipe that offers ID up to 7% larger than Schedule 10 and 11% larger than Schedule 40 for improved hydraulics. Mega-Flow saves freight, labor and installation costs with standard hanger spacing (15') and standard and custom lengths. With its proprietary mill coating, Mega-Flow is an excellent alternative to standard wall products so you can downsize your entire sprinkler system with the same or greater quality. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOM ID (LBS.) H2O FILLED ./FT 21 24 25' 1Y4 1.530 1.108 1.904 61 1419 1622 1690 - . 11/2 1.740 1.556 2.586 61 1993 2278 2373 -, 2 2.215 1.961 3.631 37 1524 1741 1814 21/2 2.707 2.504 4.998 30 1578 1803 1878 :tc-' :arc 3 3.316 3.349 7.090 19 1336 1527 1591 - ,5I , 1 'gtr( 4 4.316 4.331 10.669 19 1728 1975 2057 6 6.395 8.000 21.900 10 1680 1920 2000 E, flr SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-FLOW .';)I' . ' rn rq Schedule Schedule Schedule Mega-Flow 10 40 Mega-Flow 40 Nominal wt./ft. Pcs./Iift 1'/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 11/2 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 2Yz 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 0.75 1.00 8.000 10 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). Mega-Flow Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for use with roll grooved, swage grooved, plain-end couplings and welded joints for wet, dry preaction and deluge systems FM Approved for roll grooved, plain-end and welded joints for wet systems NFPA 13 and NFPA 14 r avth.e,i W, -s) col 1, QJJ11 en',d_', '(w er,~pose. ©1OD Wheatland's GL steel fire sprinkler pipe is an OD galvanized, lighter-wall, threadable product. The nominal OD provides improved hydraulics—resulting in an exceptional value. ldei fo branch line use in wet, dry, preaction or deluge 'stems - TECHNICAL DATA WT./FT, NPS NOM ID (LBS.) 1 1.103 1.370 11/4 1.448 1.761 1½ 1.688 2.033 2 2.153 2.686 WT./FT. WT./LIFT WT./ LIFT WT./LIFT H20 FILLED PCS./LIFT 21 24' 25 1.701 91 2618 2992 3117 2.365 61 2256 2578 2686 2.875 61 2604 2976 3100 4.142 37 2087 2385 2485 SPECIFICATIONS ( - c NPS NOM ID UL THREADED CRR* GL Schedule 40 GI. Schedule 40 erc Nominal Thr 1 1.103 1.049 0.61 1.00 1.00 1.370 11/4 1.448 1.380 0.39 1.00 1.00 1.761 1½ 1.688 1.610 0.31 1.00 1.00 2.033 2 2.153 2.067 0.25 1.00 1,00 2.686 Calculated using Standard UL CRP formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 7.0). GL Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Threaded and welded fittings are approved in accordance with NFPA 13 GL Pcs./Lift 91 61 61 37 - prCpr.etaI'/ m.11 coating ensures clean, corrosion- r85 stat su ce - -' WEIGHTS AND DIMENSIONS NOMINAL SIZE 00 Wall Inches 1 1.315 0.133 114 1.660 0.140 lYe 1.900 0.145 2 2.375 0.154 2½ 2.875 0.203 3 3.500 0.216 3'/a 4.000 0.226 4 4.500 0.237 5 5.563 0.258 6 6.625 0.280 jLi jLrc Kghi Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality -not to mention reliable, long-lasting performance. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WI., LIFT WT./LIFT NPS NOM ID (LBS.) H0 FILLED PCS./LIFT 21' 24 25 11/4 1.442 1.807 2.514 61 2315 2645 2756 1½ 1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.640 4.222 37 2051 2344 2442 21/2 2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.960 40.086 7 2493 2849 2968 SCHEDULE 10 SPECIFICATIONS NOMINAL NPS NOM OD NOM ID NOMINAL WALL WEIGHT UL PIECES in. mm in. mm in. mm Ibs./ft. kg/rn CRR Lift 1% 1.660 42.2 1.442 36.6 0.109 2.77 1.81 2.69 7.3 61 1'/e 1.900 48.3 1.682 42.7 0.109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 0.109 2.77 2.64 3.93 4.7 37 21/2 2.875 73.0 2.635 66.9 0.120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 0.120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 0.120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 0.134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 0.134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 0.188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NPS NOM OD NOM ID NOMINAL WALL WEIGHT UL PIECES In. mm in. mm In. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.00 70 1% 1.660 42.2 1.380 35.1 0.140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40,9 0.145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Schedule 10 and Schedule 40 Meet or Exceed These Standards ASTM A135, Type E, Grade A (Schedule 10) FM Approved ASTM A795, Type E, Grade A (Schedule 40) NFPA 13 UL and C-UL Listed SCHEDULE 40 Wt./ Ft. Ibs./ft. Filled 1.68 2.055 2.27 2.922 2.72 3.602 3.66 5.109 5.80 7.871 7.58 10.783 9.12 - 10.80 16.311 14.63 23.262 18.99 31.498 Tube tet Industries Co.-Pc Cffk. 2ist Chi:o. IL .1OO EiOLo :om 01 ID. 72 rifo wrrlrid.com i hatridcr JI 1 - NY iRi iCoTVW Pfl 101 II , iJ fiJi 41J InTle iijij JMI iiri'ciI ik*t t4Ji' 1itøIL, IF l ijiiJ iThI • oJ (9)1 thJiiiii •. • • 0)( 1j•c (1J( 1C )1(]I&CO1firI OF -: • hni (J1 hi iIoI qft-}. oloto 11tiJ Cross sPF/Nv - LISTED APPROVED For ListingslApprovel Details and Limitations, it out viebafte at v—anvilinti.com or contact an Anvil* Sales Representative. Nominal Size MaximumDimension Working PressureA A Approx. WI. Each In. (mm) PSI (kPo) In. (mm) tbs. (kg) 1 500 1.50 0.98 1¼ 500 1.75 1.50 1/s 500 1.94 1.90 2 500 2.25 2.95 A - Working Pressure Ratings are for reference only and based on Scn. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule please visit anvilinfl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than Four turns. Project: Li Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: orr,ul- I. i 0 L(SPfFWL). :-;: ... Class 123 (Standard) UQ Cored Plug LI Nominal Size Maximum Working PressureA Dimension A Approx. WI Eath In. (mm) PSI (kPsi) In. (mm) Lbs. (kg) 300 0.94 0.10 Y4 300 1.07 0.17 1 300 1.25 0.28 1114 300 1.36 0.44 1½ 300 1.45 0.62 2 300 1.56 0.91 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. * Part supplied as Solid Plug, I) LISTED APPROVED -. For LtngApprevuI Details and Umitatians, visit out website at wvev.anvi5ntt.csm or contact an Anvil' Sales Representative. Dimensions: ASME 816.14 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cost iron threaded fittings are UL/ULC Listed and FM Approved. A Pressure Temperature Ratings in accordance with ASME B16.4 Class 125 Project: J Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: orr/t.,I- 1.13 - c.SPPfNv!t_) :m ':,'A\•' Class 125 (Standard) IF001 3360-17 Reducing Coupling Nominal Size MaximumDimension Working PressureA A Approx. WI. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) lx /2 300 1.70 0.62 1 x'/4 300 1.70 0.80 A - Working Pressure Ratings are for reference only and based on 5th. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilinticom or contact your local Anvil Representative. ®s LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at wvosaurvitnticom or U, contact an Anvil' Sales Representative. Dimensions: ASME B 16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. Project: Li Approved Address: LJ Approved as noted Contractor: LI Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: ctrrfL,t- I. 0 Ea 3201 900 Elbow C us ti3 LISTED APPROVED For Ustings/Approval Details and Limitations, visit our websito at vawounvilintl.csm or contact an Anvil0 Sates Representative, Nominal Size MaximumDimension Working PressureA A Approx. WI. Each In. (mm) PSI (kPo) In. (mm) Lbs. (kg) 1 500 1.50 0.62 1114 500 1.75 0.90 11/2 500 1.94 1.20 2 500 2.25 1.85 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anviliatl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. Project: Li Approved Address: . Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: 1 of 2 GROOVED COU PLING TECHk1b4 L MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikingcorp.com 1. DESCRIPTION VGS® Model V-7705 Standard Flexible Couplings are available in sizes 1" through 12'. Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGS8 Standard Flexible Couplings are manufac- tured at lS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are availa- ble (conforming to ASTM Al 53); when order- ing, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, A\NWA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel The latest VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website Aj Model V-7705 Standard Flexible Coupling http:f/vikinggroup.mobi/p/46374 lNominal: Pipe Max. Working Axial Dimensions Soft Size _ _____ Size O.D. , Pressure Max.End DspIac3ment weight Load Lbs!kN In (mm) Lbs (g) In (mm) In (mm) PSI (Bar) In (mm) I in (mm) In (mm) in (mm). 1 1.315 300 406 0.0625 2.2 3.94 1.77 3/8 x 1-3/4 1.3 (25) (33) (21) (1.75) (1.6) (56) (100) (45) 2 (M1O x 45) (0.6) 1.25 1.66 300 649 0.0625 2.58 4.09 1.85 3/8 x 2-1/8 1.4 (32) (42) (21) (2.79) (1.6) (66) (104) (47) 2 (M10 x 55) (0.6) 1.5 1.9 300 850 0.125 2.82 4.25 1.815 3/8x2-1/8 1.6 (40) (48) (21) (3.66) (3.2) (72) (108) (47) 2 (M10 x 55) (0.7) 2 2.375 300 1330 0.125 3.39 5.12 1.89 3/8 x 2-1/8 1.9 (50) (60) (21) (5.71) (3.2) (86) (130) (48) 2 (M10 x 55) (0.9) 2.5 2.875 300 1950 0.0625 3.82 5.63 1.89 3/8 x 2-1/8 2.0 (65) (73) (21) (8.37) (1.6) (97) (143) (48) 2 (M10 x 55) (1.9) 3 3.5 300 2885 0.125 4.49 6.42 1.93 2 1/2 x 3 3.1 (80) (89) (21) (12.41) (3.2) (114) (163) (49) (M12 x 75) (1.4) 4 4.5 300 4771 0.125 5.83 7.80 2.05 1/2 x 3 4.6 (100) (114) (21) (24.77) (3.2) (148) (198) (52) 2 (M12x75) (2) 5 5.563 300 7290 0.125 6.79 9.25 2.09 2 5/8 x 3-1/2 6.3 (125) (141) (21) (32.45) (3.2) (173) (235) (53) (M16 x 90) (2.9) 6 6.625 300 10340 0.125 7.91 10.55 2.13 5/8 x 3-1/2 7.3 (150) (168) (21) (46.02) (3.2) (201) (268) (54) 2 (M16 x 90) (3.3) 8 8.625 300 17525 0.25 10.35 13.27 2.44 2 5/8 x 3-1/2 12.1 (200) (219) (21) (78) (6.4) (263) (337) (62) (M16 x 90) (5.5) 10 10.75 300 27228 0.125 12.76 15.51 2.62 I 3/4 x 4-3/4 19.7 (250) (243) (21) (121.19) (3.2) (324) (394) (67) I 2 (M20 x 120) (8.9) 12 12.75 300 1 38302 0.189 14.65 17.72 I 2.62 r 7/8 x 6-1/2 25.1 (300) (330) (21) (170.47) (4.8) (372) (450) 1 (67) 2 (M22x65) (10.9) Form No. F021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 (Reformatting and corrections) The most recent VGS5 Technical Data can be acessed at http://www.vikinggroupinc.com. Scan the code below to visit our Mobile website: I of 2 GROOVED COUPLING (('A 'ICTECHN, 4L DATA MODEL VZ05 AND VZ07 j STANDARD RIGID COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com A nra an, n1a.. 1. ucririiuci VGS® Model V-Z05 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 8". VGS111 Model V-Z07 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 10" with Gap Seal gaskets available for sizes up to 8" under Model V-Z05F. Model V-Z07 is not available with Gap Seal gaskets. Fitting solutions are avail- able in a number of styles and configurations to support a variety of applications. VGSO Standard Rigid couplings are manufactured at IS09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are avail- able (conforming to ASTM A153); when or- dering, add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM 02000, AWl/VA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA 1 7404to Ij Model V-Z05 and V-Z07 Standard Rigid Couplings Nominal Pipe tlax. Working Dimensions Bolt Size ,. I Size , Pressure fax. End Axial in (mm) in (mm) PSI (Bar) Load LbsIiN OtspIacemet A B C Lbo/g in (mm in (mm in (mm) V-Z05 and V-ZO5F 1.25 1.66 300 649 0-0.05 2.58 4 1.85 1.5 (32) (42.2) (21) (2.8) (0-1.2) (66) (102) (47) 2 - 3/8 2 1/8 (0.7) 1.5 1.9 300 850 0-0.05 2.83 4.33 1.85 1.7 (40) (48.3) (21) (3.66) (0 - 1.2) (72) (110) (47) 2 - 3/8 2 1/8 (0.8) 2 2.375 300 1330 0-0.07 3.35 4.62 1.89 1.9 (50) (60.3) (21) (5.71) (0 -1.7) (85) (118) (48) 2 3/8 2 -3/ (0.9) 2.5 2.875 300 1950 0-0.07 3.82 5.24 1.89 2.1 (65) (73) (21) (8.37) (0-1.7) (97) (133) (48) 2 - 3/8 23/4 (0.9) 3 3.5 300 2885 0-0.07 4.49 5.91 1.93 2.7 (80) (88.9) (21) (12.41) (0 - 1.7) (114) (150) (49) 2 - 3/8 23/4 (1.2) 4 4.5 300 4771 0 -0.16 5.75 7.48 2.17 (100) (114.3) (21) (24.77) (0-4.1) (146) (190) (55) 2 1/2 3 4.3 (2) 5 5.563 300 7290 0-0.16 6.87 9.11 2.15 5.8 (125) (141.3) (21) (32.45) (0-4.1) (175) (232) (55) 2 1/2 x 3 (2.6) 6 6.625 300 10340 0-0.16 7.87 10.24 2.17 (150) (168.3) - (21) (46.02) (0-4.1) (200) (260) (55) 2 58 55/16 ' (3.2) 8 8.625 300 17525 0 -0.19 10.28 12.89 2.52 13.3 (200) (219.1) (21) (78) (0-4.8) (261) (328) (65) 2 5/8 x -5I16 (8) VZ07* 10 10.75 300 27190 0- 0.13 12.99 15.59 2.5 - 23.5 254 273 21 123 0 - 3.2 330 396 1 64 2 7/8 x 6-1/2,, 10.7 Not available with gap seal Form No. F_020614 16.03.04 Rev 16.1 Replaces form No. F_020614 Rev 15.1 (Reformatting and corrections) I of 2 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818.1680 Email: techsvcsvikingcorp.com DESCRIPTION VGSO Model V-7110, V-7111, V-7112, and V-7113 Elbows are available in sizes 1-1/4" through 12'. Fitting solutions are available in a number of styles and con- figurations to support a variety of applications. VGS® grooved-end fittings are manufactured at 1S09001 certified facilities and are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to meet ASTM F1548 and ANSI/AWWA C606 requirements for use with grooved mechanical couplings conforming to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZA Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM A153); when ordering, add a "G" suffix to the Model number. The latest VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: DE bi I' P IWAMO., http://vikinggroup.mobi/p/46374 CE Model V-7110 Model V-7112 90° Elbow 22-1/2° Elbow ,7~ > C.E Model V-7111 Model V-7113 45° Elbow 11-1/4° Elbow C) M D Model V-711ODR 90° Drain Elbow V.7110 V-7111 V-7112 V-7113 Nominal 90° Elbow 45° Elbow 22.5° Elbow 11.25° Elbow C-E C-E C-E C.E Size Pipe O.D. in (mm) in (mm) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) 1.25 1.66 2.75 1.1 1.75 0.8 1.75 0.64 1.38 0.51 (32) (42) (70) (0.48) (45) (0.37) (45) (0.29) (35) (0.23) 1.5 1.9 2.75 1.3 1.75 1.01 1.75 0.97 1.38 0.68 (40) (48) (70) (0.59) (45) (0.45) (45) (0.44) (35) (0.31) 2 2.375 3.25 2 2 1.4 1.89 1.4 1.38 1 (50) (60) (83) (0.89) (51) (0.65) (48) (0.63) (35) (0.45) 2.5 2.875 3.75 2.9 2.25 1.98 2.01 1.83 1.5 1.39 (65) (73) (95) (1.3) (57) (0.9) (51) (0.83) (38) (0.63) 3 3.5 4.25 4.6 2.5 3.2 2.25 2.54 1.5 2.05 (80) (89) (108) 1 (2.1) (64) (1.45) (57) (1.15) (38) (0.93) 4 4.5 5 7 3 4.85 2.87 487 1.75 2.78 (100) (125) (127) (3.18) (76) (2.2) (73) (2.21) (45) (1.26) 5 5.563 5.5 9.8 3.25 7.1 (125) (141) (140) (4.42) (83) (3.2) -- 6 6.625 6.5 13.8 3.5 9.26 3.11 8.89 2 6.04 (150) (168) (166) (6.27) (89) (4.2) (79) (4.03) (51) (2.74) 8 8.625 7.75 27.1 4.25 17.99 3.86 18.19 2 10.54 (200) (219) (197) (12.3) (108) (8.16) (98) (8.25) (51) (4.78) 10 10.75 9 50.6 4.75 32,34 4.37 33.03 2.7 22.8 (250) 1 (273) (229) (23.4) (121) (14.76) (111) (14.98) (66.5) (9.89) 12 12.75 10 75.4 5.25 42.31 (300) (325) (254) (32.2) (133) (19.19) Form No. F_101515 16.12.15 Rev 16.1 Replaces Form No. F101515 Rev 15.1 (Revised Fig 1) Set Screw and Locknut Included 4 Beam Camps Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65X1 - Reversible Steel C4ype Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) jj'\ U us LISTED Size Range: Fig. 65 - 1/7'13 rod sizes, and /8'-11 rod sizes Fig. 65XT - f8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May he used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, Ie-16 rod will support 1/2" (15mm) thru 4" (100mm) pipe 1/2'13 rod will support thru 8" 200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. (mm) 65_1/2 u/2"_13 1V2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 /811-11 1 1/2" (38.1) 3/4" 119.01 1" (25.4) /i" (14.3) Part F Approx, Wt./100 No. in. (turn) Lbs. (kg) 65-1I2 11/4" (31.7) 55 (24.9) 1' 65-I8 11/4" (31.7) 55 (24.9) Fig. 65X1-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. 12.7kg) Finish: Plain or Electro-Galvanized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" 1100rnm1 pipe. Designed to meet or exceed requirements of FM DS 2-0. (25.4) /- 1I 2 Set Screw and 1" Lcckuut Included (22.2) (34.9) c®uS LISTED All dimensions in charts and on dravvngs al-s in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 13 B-Line L • - Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6 pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material C®US LISTED C. 1 B A Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs, Wt./100 21/2 1/2* 53/4 41/4 15/8 600 41 3 1/2k 6 41/5 11/4 600 45 31/2 1/2* 73/8 51/4 21/s 600 52 4 5/8* 73/8 5 15/8 1000 59 5 5/8 9 6/8 21/4 1250 97 6 3/4 9/8 61/2 17/6 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737 5599 • FAX. 951.737.0330 CUSTOMER SERVICE • 800,786.5266 www.folco.com VK544 VK545 VK546 1 Thread Size K-Factor 1-1/4" NPT (32 mm BSP) 11.2 (161.3 Metric) SIN Style VK544 Plain Barrel VK545 Adjustable Recessed VK546 Adjustable Standard Page 1 o 9 STANDARD RESPONSE r TE4NIALPTA i DRY PENDENT _____________________ I ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent ELO sprinklers are FM Approved for storage and non-storage applications. In certain FM cold storage installations, the dry ELO sprinklers can provide a design advantage with lower overall water demands. In these applications, the dry ELO must be installed on a wet pipe system, per FM data sheet 8-9. In non-storage applications, when used in dry or preaction systems, the sprinklers are designed to prevent water or condensation from entering the drop nipple before the sprinkler operates. Viking Standard Response Dry Pendent ELO Sprinklers are available in various finishes and temperature ratings to meet design requirements. The optional dry sprinkler boot assembly is intended to slow the exchange of air between the inside and outside of the freezer (or any dry sprinkler installation) to help prevent humidity and temperature differential in the area around the sprin- kler. Condensation can lead to ice build-up, which could inhibit sprinkler operation or cause premature operation. If using the insulating boot assemblies included with your sprinklers (optional for installation), follow the installation instructions in this technical data page. Insulating boot assemblies, if used, shall be installed on smooth, flat, and clean surfaces. There are specific installation situations, as with corrugated ceiling panels, where alternative penetration sealing methods may be utilized. For additional information contact Viking Technical Services. LISTINGS AND APPROVALS FM Approved: Classes 2013 and 2015 FM Refer to Approval Chart and Design Criteria on page 4 for FM APPROVED Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1-1/4" NPT or 32 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric**) for all listed and approved lengths. * FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). **Metric K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass Fusible Link Assembly: Beryllium Nickel, coated with Polyurethane Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C36000 Pip Cap Adapter: Brass UNS-C36000 Orifice: Brass UNS-C36000 Tube: ERW Hydraulic Steel Tube Barrel End and Threads: QM Brass Support (Internal): QM Brass Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089M/B.) Page 3 of 9 STANDARD RESPONSE TECHNICAL DATA DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TA Instruct ;ize Sprinkler 1: _Finishes 2: Temperature Ratings Description Suffix' Nominal Frame Max. Ambient Suffix Model Base Part NPT BSP No. Inch ' mm Rating4 Paint Color Ceiling Temperature2 VK544 19830 1-1/4 -- Brass' A 165°F(74°C) None 100°F(38°C) C 19831 -- 32 Chrome F 205 °F (96 °C) White 150 °F (65 °C) E VK545 19835 1-1/4 -- White Polyester M-/W 280°F(138°C) Blue 225°F(107°C) G 19836 -- 32 VK546 19840 1-1/4 -- 19841 -- 32 12 (305) 18 (457) The "A" Dimension is the distance as 3. Available "A" Lengths 24 (610) measured from the face of the fitting Inches (mm) 30 (762) in which the sprinkler will be installed A 36 (914) to the face of the finished ceiling in the 42 (1067) protected area. See Figures 2, 3, and 4 - 48 (1219) Example: 19835FC12 is a VK545 with a Chrome finish and a 165 temperature rating with A" dimension of 12 inches. This sprinkler is to be installed into an area with a maximum ambient temperature of 100°F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrench5: Socket Wrench (for Recessed sprinklers): Part No. 19748W/B - requires a 1/2" ratchet (not available from Viking) Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 19730. Recessed Dry Escutcheon Cup: Base Part No. 19728. Dry Barrel Seals: (NOTE: 2 seals are included with each VK544 and I with each VK545 or VK546) Part No. 22089M/B Footnotes 1. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix, z Based on NFPA 13 Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The VK544 is the only sprinkler available with a brass finish. The VK545 is not available with a 280°F (138 °C) temperature rating. For Standard Adjustable and Plain Barrel sprinklers, use a pipe wrench applied on the inlet housing. Form No. F_040815 18.08.02 Rev. 18.1 Page 5 of 9 'I STANDARD RESPONSE N it ii'%M I:ll[.c..Iu.7.If DRY PENDENT •J ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For 'A" Dimension: Determine the distance from the face of the tee to the finished ceiling. Round to the nearest 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m). Per "A" dimension, the deflector will be located approximately 4" (102 mm) below the ceiling. (32 mm) tee Ell NPT (32 mm) Minimum ceiling opening diamter: A —2"(5lmm) ,7 Maximum ceiling opening diameter: ' 2-3/8" (61 mm) Finished ceiling7 (21 mm) Sleeve finish - matches ) escutcheon (48 mm) 3-7/8" diameter (99 mm) Deflector at minimum distance below ceiling. NOTE: To locate the - deflector at the minimum Deflector at maximum - distance below the ceiling, distance below ceiling. with no upward NOTE: To locate the adjustment available, deflector at the maximum order the dry pendent distance below the ceiling, 10" sprinkler as per the "A" with no downward 254 mm) dimension, adjustment available, Maximumorder the dry pendent sprinkler 6" (153 mm) - I " longer than the "A" - J J(102 mm) dimension. _JMinimum Figure 2: Adjustable Standard Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 7 of 9 STANDARD RESPONSE 4.4 7 AM71 TECHNICAL DATA DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For "A" Dimension: Determine the distance from the face of the tee to the base of the sprinkler. Round up to the next higher 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m) ,-1-1/4' (32 mm) tee 1-1/4" NPT (32 mm)— I A Outside diamter: 1-11/16" (43 mm) 1k I t 2-1/16" (53 mm) Figure 4: Plain Barrel Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 9 of 9 STANDARD RESPONSE I J~2~ - 3A TECHNICAL DATA DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Boot assembly (optional) / Part No. 22089M1W (or equivalent method) ll Clearance oPeig Insulated ceiling Dry Sprinkler Seal on the Exterior of the ceiling I 77 Seal Insulated ceiling Dry Sprinkler Seal Within the ceiling Figure 6: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089MfB.) #10 Tapping Screw (25 mm) Page 2 of 4 Ilu DRY SPRINKLER INSULATING BOOT ASSEMBLIES - N The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinccom 4. INSTALLATION Prepare the sprinkler installation opening as indicated in the installation instructions on Form No. F_080614 and the appropriate sprinkler technical data page. Then install the dry sprinkler through the clearance opening. Install the dry sprinkler on the piping per the instructions on page Form No. F_080614 and the dry sprinkler data page for the sprinkler model being used, taking care not to over-tighten or damage the sprinkler. Clean the contact surfaces of the dry sprinkler seal and the surface of the wall or ceiling. Slide the dry sprinkler boot over the dry sprinkler barrel and to the ceiling, deck, or wall until the seal rests against the surface of the ceiling, deck, or wall. Assemble the ring onto the seal, hold in place, and tighten the four screws through the holes provided in the assembly. NOTE: A #29 drill is required for a pilot hole in metallic ceilings, decks, or walls. 5. INSPECTIONS, TESTS AND MAINTENANCE A. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. Remove the system from service, drain all water, and relieve all pressure on the piping. Remove the dry sprinkler boot assembly. Using the special sprinkler wrench, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response charac- teristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Install a new Dry Sprinkler Boot Assembly. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. B. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combus- tion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. AVAILABILITY The Viking products are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Under Seal Ring For 22087M/W: Fits 1-5/16" (33 mm) O.D. Barrel , For 22069MAN: Fits 1-11/16" (43 mm) O.D. Barrel Over Seal Ring - Figure 1: Dry Sprinkler Insulating Boot Dimensions Form No. F030107 18.08.02 Rev 18.1 Page 4 of 4 DRY SPRINKLER N I IM INSULATI NG BOOT ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com *10 TAPPING SCREW OVER SEAL RING UNDER SEAL C1earoice Opening Insulated Ceftg Structure STEP 0 INSTALL SEAL AROUND BARREL OF DRY SPRINKLER WOOD - NO PILOT HOLE REQUIRED :TAL - DRILL PILOT HOLE FOR SCREWS CIearace y Opening suIate ol CeUrg Structure STEP 2 PLACE SEAL FLUSH WITH TOP OF FREEZER AND SECURE AROUND BARRELL Opening In suLatecl CeI1ng Structure STEP 4 SECURE INSULATING RING TO TOP OF FREEZER WITH *10 TAPPING SCREWS Figure 3: Dry Sprinkler Insulating Boot Assembly - Installation Sequence (Dry Pendent Sprinkler Shown) Form No. F_030107 18.08.02 Rev 18.1 Replaces Form No. F_030107 Rev 16.1 (Replaced 19330M/W with 22089M= and 19398M/B with 22087M/B) Protective Sprinkler Cap Page 2 of 6 QUICK MICROFASTO D RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories' section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Too]*** Part No. 15915 (available since 2010) **A 1/2' ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfasta Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler F_, Clip Wrench Flat Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F033314 16.01.28 Rev 16.1 Page 4 of 6 ® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com :pio'l Chart - .- - The "dig tcrofect Qic Rspns- , KEY :2enc3n Sprint't'r 302 A1X4 ;cxtzrwm 17$ PS1 02 Bari V.10 - Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB I (E 7 0 12979 VK302 Pendent 1/2 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2,C2X Al A1Z, B1Y D1Z, dY -- D3Z 06662B VK302 Pendent 1/2"1 15mm 5.6 80.6 2-1/4 58 AiZ, B1Y, D2, C2X -- -- -- 18021 VK302 Pendent 1/2' 115mm 5.6 80.6 1 2-1/4 58 AiX, B1Y Al I AiX, B1Y Dlx, Cit'8 Dlx, dY9 -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 °F (57 'C), 155 'F (68 'C), 175 'F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 'C), 200 'F (93 'C), 286 'F (141 'C) Polyester56, Black Polyes- Viking Micromatic5 Model E-1 Recessed Escutcheon B - 135 °F (57 'C), 155 'F (68 'C), 175 'F ter Y - Standard surface-mounted escutcheon or the (79 'C), and 200 'F (93 'C) 2 - ENT5 Viking Microfast5 Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C -155 'F (68 'C), 175 'F (79 'C), and 3-Chrome mati& Model E-1, E-2, or E-3 Recessed Escutcheon 200 'F (93 'C) Z - Standard surface-mounted escutcheon or the D- 155°F (68 'C), 175°F (79 'C), 200°F Viking Microfast5 Model F-I Adjustable Escutcheon (93 'C), 286 'F (141 'C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, Ed-certificates of conformity 0832-MED-1 003 and 0832-MED-1 008. DESIGN CRITERIA - UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking Microfast5' Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies, The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 16.01.28 Rev 16.1 Page 6 of 6 kil.Ia:I MICROFAST@ QUICK The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com - J -1 Ceiling Opening Size: j f 2-5/16" (58.7 mm) minimum 1/2" ' (16 mm) 2-1/2" (63.5 mm) maximum I i NPT 2-1I8" (64 mm) : (44.5 mm) Max. (5 mm) (38 mm) Installed with a standard Installed with a Microfast Note: At maximum, adapter is 1/8" surface-mounted Model F-I Adjustable exposed 112" (12.7 mm) from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon - Ceiling Opening Size: 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 2-1/8" 2-1/8" (54 mm) 454 mm) 7 ] F I F -3/4' (28mm) L. (28.6 (44.5 mm) Max. (61 mm) Max. - Installed with a Installed with a Model Model E-I Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model El and E-2 Recessed Escutcheons Form No. F033314 16.01.28 Rev 16.1 Replaces Form F 0333314 Rev 15.2 (Revised temperature suffix designation) FIRE SPRINKLER MATERIAL DATA Prepared by: Ci?I! nrgfireconsulting.com 7511 Greenwood Ave N #600 Seattle, WA 98103 (206) 789-0165 Anjanette Wiseman, CET Fire Protection Designer Project: Costco #462 Carlsbad, CA Freshline - Cooler - Freezer Renovations 951 Palomar Airport Rd. Carlsbad, CA 92011 October 19, 2018 SECTION 1 Wheatl and Tube Fhe SpftMer Products Wheatland Tube began producing steel fire sprinkler pipe in 1931, and today offers the most complete line of products in the industry. Engineers and contractors across the continent depend on us for steel fire sprinkler pipe and a number of proprietary products— always in stock and ready to deliver. 100% Compatibility We guarantee our steel pipe is 100% compatible with fire protection systems that use only steel pipe. Why risk incompatibility? Wheatland's complete line of steel sprinkler pipe makes design easy and brings you peace of mind. Accurate and Efficient Our products help you work safer and smarter—not harder. With our extensive in-house capabilities, we offer the shortest production cycle times in the industry, and we deliver to you accurately and on time, every time. Wheat/and Tube has never warranted compatibility between its steel pipe products and CPVC products. Green and Sustainable Our steel fire sprinkler pipe contains recycled steel and provides decades of reliable service. At the end of its life, the steel may be almost fully recycled, supporting your green policies. Zekelman Industries Wheatland Tube is a division of Zekelman Industries, the largest independent manufacturer of steel hollow structural sections (HSS) and steel pipe in North America. We leverage our 100-plus years of pipe and tube manufacturing experience and expertise to produce 2 million tons of pipe and tube annually. Backed by Zekelman Industries, you can count on Wheatland for strength, innovation and service - bringing exceptional value to your business. ID _'ID tc iarger t a Schedule 10 and 1'V E'er ta' Schice 3 ega4ow ea~)_, ~~ e v i,;T d mNv \\7 Wheatland's Mega-Flow is an engineered, light-wall steel sprinkler pipe that offers ID up to 7% larger than Schedule 10 and 11% larger than Schedule 40 for improved hydraulics. Mega-Flow saves freight, labor and installation costs with standard hanger spacing (15') and standard and custom lengths. With its proprietary mill coating, Mega-Flow is an excellent alternative to standard wall products so you can downsize your entire sprinkler system with the same or greater quality. TECHNICAL DATA WT./FT. WT./FT. WT,/LIFT WT./LIFT WT./LIFT -. - NIPS NOM ID (L8S.) H2O FILLED PCS./LIFT 21 24' 25' 11/4 1.530 1,108 1904 61 1419 1622 1690 1'/2 1.740 1.556 2.586 61 1993 2278 2373 2 2.215 1.961 3.631 37 1524 1741 1814 21/z 2.707 2.504 4.998 30 1578 1803 1878 3 3.316 3.349 7.090 19 1336 1527 1591 * S - .. 4 4.316 4.331 10.669 19 1728 1975 2057 6 6.395 8.000 21.900 10 1680 1920 2000 SPECIFICATIONS - . . . NPS NOM OD NOM ID ULCRR MEGA-FLOW - r • , Mega-Flow Schedule Schedule Mega-Flow Schedule Nominal 1'/a 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 1'/2 1.900 1.740 1.682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 21/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4,500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 0.75 1.00 8.000 10 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CRP is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). Mega-Flow Meets or Exceeds These Standards: ASTM A795, Type E, Grade A UL and C-UL Listed and FM Approved for use with roll grooved, swage grooved, plain-end couplings and welded joints for wet, dry preaction and deluge systems FM Approved for roll grooved, plain-end and welded joints for wet systems NFPA 13 and NFPA 14 L Galvanized, f Ight Wall, C e &L"' cc) V 0 % 00 ®[ Wheatland's GL steel fire sprinkler pipe is an OD galvanized, lighter-wall, threadable product. The nominal OD provides improved hydraulics—resulting in an exceptional value. Idea f' in wet, ciry, Dreaction or :€Lcie :stems TECHNICAL DATA WT./FT, NPS NOM ID (LBS.) 1 1.103 1.370 11/4 1.448 1.761 1% 1.688 2.033 2 2.153 2,686 WT./FT. 1120 FILLED PCS./LIFT 1.701 91 2.365 61 2.875 61 4.142 37 WT./LIFT WT./ LIFT WT./LIFT 21 24' 25' 2618 2992 3117 2256 2578 2686 2604 2976 3100 2087 2385 2485 SPECIFICATIONS NPS NOM ID UL THREADED CRR*01. - GL Schedule 40 GL Schedule 40 Nominal Pcs./LIft Thread wt./ft. 1 1.103 1.049 0.61 1.00 1.00 1.370 91 11/4 1.448 1.380 0.39 1.00 1.00 1.761 61 11/2 1,688 1.610 0.31 1.00 1.00 2.033 61 2 2.153 2.067 0.25 1.00 1.00 2.686 37 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of t. 0). GL Meets or Exceeds These Standards: ASTM A795, Type E, Grade A for fire sprinkler applications up to 300 psi working pressure UL and C-UL Listed and FM Approved for wet, dry and preaction deluge systems FM Approved for use in wet systems Threaded and welded fittings are approved in accordance with NFPA 13 4 WEIGHTS AND DIMENSIONS NOMINAL SIZE OD Wall -n. Inches 1 1.315 0.133 1'/a 1.660 0.140 11/2 1.900 0.145 2 2.375 0.154 21/2 2.875 0.203 3 3.500 0.216 3'/2 4.000 0.226 4 4.500 0.237 5 5.563 0.258 6 6.625 0.280 SCHEDULE 40 Wt Wt./Ft. lbs./ft. Filled 1.68 2.055 2.27 2.922 2.72 3.602 3.66 5.109 5.80 7.871 7.58 10.783 9.12 - 10.80 16.311 14.63 23.262 18.99 31.498 SCheie 10 ai SchecIe 40 r, [i3)Lr1J Fv; Vj[ Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe are subjected to the toughest possible testing to ensure the highest possible quality-not to mention reliable, long-lasting performance. TECHNICAL DATA WT./FT. WT./FT. WT./LIFT WT./ LIFT WT./LIFT NPS MOM ID (LBS.) H0 FILLED PCS./LIFT 21 24 25 11/4 1.442 1.807 2.514 61 2315 2645 2756 11/2 1.682 2.087 3.049 61 2673 3055 3183 2 2.157 2.640 4.222 37 2051 2344 2442 2% 2.635 3.534 5.895 30 2226 2544 2651 3 3.260 4.336 7.949 19 1730 1977 2060 4 4.260 5.619 11.789 19 2242 2562 2669 5 5.295 7.780 17.309 13 2124 2427 2529 6 6.357 9.298 23.038 10 1953 2232 2325 8 8.249 16.960 40.086 7 2493 2849 2968 SCHEDULE 10 SPECIFICATIONS NOMINAL NPS MOM OD MOM ID NOMINAL WALL WEIGHT UL PIECES In. mm in. mm In. mm Ibs./ft. kg/rn CRRI Lift 1% 1.660 42.2 1.442 36.6 0.109 2.77 1.81 2.69 7.3 61 1'/s 1.900 48.3 1.682 42.7 0.109 2.77 2.09 3.11 5.8 61 2 2.375 60.3 2.157 54.8 0.109 2.77 2.64 3.93 4.7 37 2'/e 2.875 73.0 2.635 66.9 0.120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 0.120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 0.120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 0.134 3.40 7.78 11.58 1.5 13 6 6.625 168.3 6.357 161.5 0.134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 0.188 4.78 16.96 25.26 2.1 7 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of to). SCHEDULE 40 SPECIFICATIONS NOMINAL NPS MOM OD MOM ID NOMINAL WALL WEIGHT UL PIECES In. mm in. mm in. mm Ibs./ft. kg/rn CRR' Lift 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.50 1.00 70 11/4 1.660 42.2 1.380 35.1 0.140 3.56 2.27 3.39 1.00 51 1112 1.900 48.3 1.610 40.9 0.145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 0.154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CPR formula, UL Fire Protection Directory, Category VIZY The CPR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of to). Schedule 10 and Schedule 40 Meet or Exceed These Standards: ASTM A135, Type E. Grade A (Schedule 10) . FM Approved ASTM A795, Type E, Grade A (Schedule 40) • NFPA 13 UL and C-UL Listed Proorietar; ni :oatng ensures cean, corrosion- restant sLr,ce - t, 'ot [ Tube oqp cP eta Industries 000 Corpcu Ofc !hFlair1-rr .2 7 1 C. CC :VIn I SPFIRNVL)))) ©i FOB. 35,207 Cross A ——A JF'o,'Llstings/Approval c®us LIED APPROVED Detuds and Utnitutians, our website at www.anvitntl.com nr act an AnviP Sales Representative. iI 1 Nominal Size Maximum Dimension Working PressureA A Approx. WI. Each In. (mm) PSI (kPa) In. (mm) Lbs. (kg) 1 500 1.50 0.98 lA 500 1.75 1.50 1Y2 500 1.94 1.90 2 500 2.25 2.95 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. 1i!W!lIli5 1il? Project: IU Approved Address: U Approved as noted Contractor: U Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: rriut- I. 10 Q(QSPF/RNVL) I9J E Ni I Class 125 (Standard) Cored Plug El Nominal Size Max im um Working PressureA Dimension A Approx. WI. Each In. (mm) PS! (kPa) In. (mm) tbs. (kg) 300 0.94 0.10 1/4 300 1.07 0.17 1 300 1.25 0.28 11/4 300 1.36 0.44 1/2 300 1.45 0.62 2 300 1.56 0.91 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. .' Part supplied as Solid Plug. (JL\ I TTI LISTED APPROVED II_- For LisSngs/rovat Details and Limitations, - . Visit our webeite at vrewnnvitinticunt or contact an Anuitt Sates Representative. Dimensions: ASME 816.14 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME B1.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. A Pressure Temperature Ratings in accordance with ASME B 16,4 Class 125 1,7 .- . Project: LJ Approved Address: Approved as noted Contractor: LJ Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: / C®US LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at yavw.anvilinttcnnr Or contact an Anvil5 Sales Representative. Dimensions: ASME B16.4 Class 125 Material: ASTM A126 Finish: Black or Hot Dip Galvanized per ASTM A153 Class A Threads: NPT per ASME 81.20.1 Agency Approvals: All cast iron threaded fittings are UL/ULC Listed and FM Approved. - .' (C('SPFfRNVl) L Class 125 (Standard) 1 Reducing Coupling u -------1 IJ Nominal Size Maximum Working PressureA Dimension A Approx. WI. Each In. (mm) PSI ON In. (mm) tbs. (kg) lx /2 300 LiD 0.62 1 x'/4 300 1 1.70 0.80 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, and FM pressure ratings versus pipe schedule please visit anvilinti corn or contact your local Anvil Representative. Project: LJ Approved Address: Approved as noted Contractor: Lj Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: orr/ui 1.10 900 Elbow Nominal Size MaximumDimension Working PressureA A Approx. Wt. Each In. (mm) PSI (kPo) In. (mm) lbs. (kg) 500 1.50 0.62 11/4 500 1.75 0.90 l/t 500 1.94 1.20 2 500 2.25 1.85 A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the I. UL/ULC, and FM pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. fI /c®im LISTED APPROVED - For Listings/Approval Details and Limitations, visit our viebsde at www.anvilintt.com on contact an Anvil* Sales Representative. I ?1 Dimensions: ASME B16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. .. ,:../.. . Project: Li Approved Address: Li Approved as noted Contractor: Li Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: rr,ut- I. ID 1 of 2 \fl ® GROOVED COUPLING TECHNICAL DATA MODEL V-7705 STANDARD FLEXIBLE COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION VGS® Model V-7705 Standard Flexible Couplings are available in sizes 1" through 12. Fitting solutions are available in a number of styles and configurations to support a variety of applications. VGS11 Standard Flexible Couplings are manufac- tured at 15,09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are availa- ble (conforming to ASTM Al 53); when order- ing, add a 'G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM 02000, AWWA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel The latest VGSO Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: 001M.A191 http://vikinggroup.mobi/p/46374 0 Model V-7705 Standard Flexible Coupling INominal! Pipe T Bolt Size r4ax. End ______________ ______ ___________- Weight Size O.D. Pressure Displacement in (mm) in (mm) PSI (Bar) in (mm) No. in (mm) Lbs (Kgs) in (mm) i In (mm) in (mm) i 1.315 300 406 0.0625 2.2 3.94 1.77 3/8 x 1-3/4 1.3 (25) (33) (21) (1.75) (1.6) (56) (100) (45) 2 (MIOx 45) (0.6) 1.25 1.66 300 649 0.0625 2.58 4.09 1.85 2 3/8 x 2-1/8 1.4 (32) (42) (21) (2.79) (1.6) (66) (104) (47) (MIOx 55) (0.6) 1.5 1.9 300 850 0.125 2.82 4.25 1.815 3/8 x 2-1/8 1.6 (40) (48) (21) (3.66) (3.2) (72) (108) (47) 2 (M10 x 55) (0.7) 2 2.375 300 1330 0.125 3.39 5.12 1.89 2 3/8 x 2-1/8 1.9 (50) (60) (21) (5.71) (3.2) (86) (130) (48) (M10 x 55) (0.9) 2.5 2.875 300 1950 0.0625 3.82 5.63 1.89 3/8 x 2-1/8 2.0 (65) (73) (21) (8.37) (1.6) (97) (143) (48) 2 (M10 x 55) (1.9) 3 3.5 300 2885 0.125 4.49 6.42 1.93 2 1/2 x 3 3.1 (80) (89) (21) (12.41) (3.2) (114) (163) (49) (M12 x 75) (1.4) 4 4.5 300 4771 0.125 5.83 7.80 2.05 1/2 x 3 4.6 (100) (114) 1 (21) (24.77) (3.2) (146) (198) (52) 2 (M12 x 75) (2) 5 5.563 300 7290 0.125 6.79 9.25 2.09 2 5/8 x 3-1/2 6.3 (125) (141) (21) (32.45) (3.2) (173) (235) (53) (1016 x 90) (2.9) 6 6.625 300 10340 0.125 7.91 10.55 2.13 2 5/8 x 3-1/2 7.3 (150) (168) (21) (46.02) (3.2) (201) (268) (54) (M16 x 90) (3.3) 8 8,625 300 17525 0.25 10.35 13.27 2.44 5/8 x 3-1/2 12.1 (200) (219) (21) (78) (6.4) (263) (337) (62) 2 (M16 x 90) (5.5) 10 10.75 300 27228 0.125 12.76 15.51 2.62 2 3/4 x 4-3/4 19.7 (250) (243) (21) (121.19) (3.2) 1 (324) (394) (67) (M20 x 120) (8.9) t 12 12.75 300 38302 0.189 14.65 17.72 2.82 7/8 x 6-1/2 25.1 (300) (330) (21) 1 (170.47) (4.8) (372) 1 (450) (67) 1 2 (M22 x 65) (10.9) Form No. F021214 16.03.04 Rev 16.1 Replaces form No. F_021214 Rev 15.1 (Reformatting and corrections) The most recent VGSO Technical Data can be acessed at http://www.vikinggroupinc.com. Scan the code below to visit our Mobile website: 1 of 2 '\ \ 6 ç-® GROOVED COUPLING [t MODEL VZ05 AND VZ07 STANDARD RID COUPLING The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com '11 . UtI.NlPIIUN VGS5 Model V-Z05 Standard Rigid Couplings are avaialble in sizes 1-1/4" through 8". VGS5' Model V-Z07 Standard Rigid Couplings are avalaible in sizes 1-1/4" through 10" with Gap Seal gaskets available for sizes up to 8" under Model V-ZO5F. Model V-Z07 is not available with Gap Seal gaskets. Fitting solutions are avail- able in a number of styles and configurations to support a variety of applications. VGS5 Standard Rigid couplings are manufactured at 1S09001 certified facilities an are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to conform to ASTM F1476. Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are avail- able (conforming to ASTM Al 53); when or- dering. add a "G" suffix to the Model number. Rubber compound EPDM Grade E conforming to ASTM D2000, AW\NA C606, NSF 61 and IAPMO. Nuts: Zinc plated, Carbon Steel conforming to ASTM A563 Grade B Track Bolts: 10B21 Boron Steel LISTINGS AND APPROVALS c®us Guide No. VIZM Class 1920 TECHNICAL DATA jj Model V-Z05 and V-Z07 Standard Rigid Couplings * tomlnal Pipe Lax. Worting I Dimon ions Bolt Size O.D. Press--ire LSizo d Weight in in A mm)I_in (mm)I' oad Lbs/kN Displacement J No. in Lbs/Kg V-Z05and V-ZOSF 1.25 (32) 1.66 (42.2) 300 (21) 649 (2.8) 0-0.05 (0 -1.2) 2.58 (66) 4 (102) 1.85 (47) 2 - 3/8 2 1/8 1.5 (0.7) 15 1.9 300 850 0-0.05 2.83 4.33 1.85 1.7 (40) (48.3) (21) (3.66) (0 -1.2) (72) (110) (47) 2 - 3/8 2 1/8 (08) 2 2.375 300 1330 0-0.07 3.35 4.62 1.89 1.9 (50) (60.3) (21) (5.71) (0-1.7) (85) (118) (48) 2 - 3/8 23/4 (0.9) 2.5 2.875 300 1950 0 -0.07 3.82 5.24 1.89 2.1 (65) (73) (21) (8.37) (0-1.7) (97) (133) (48) 2 - 3/8 2 3/4 (0.9) 3 3.5 300 2885 0-0.07 4.49 5.91 1.93 2 /8 x 2-3/4 2.7 (80) (88.9) (21) (12.41) (0-1.7) (114) (150) (49) (1.2) 4 4.5 300 4771 0 -0.16 5.75 7.48 2.17 2 1/2 3 4.3 (100) (114.3) (21) (24.77) (0-4.1) (146) (190) (55) (2) 5 5.563 300 7290 0-0.16 6.87 9.11 2.15 5.8 (125) (141.3) (21) (32.45) (0-4.1) (175) (232) (55) 2 1/2 x 3 (2.6) 6 6.625 300 10340 0-0.16 7.87 10.24 2.17 (150) (168.3) (21) (46.02) -(0 -4.1) (200) (260) (55) 2 - 5/8 5 5/16 (3.2) 8 (200) 8.625 (219.1) 300 (21) 17525 (78) 0-0.19 (0-4.8) 10.28 (261) 12.89 (328) 2.52 (65) 2 5/8 x -5I16 13.3 -(6) VZ07* 10 10.75 300 27190 0 -0.13 12.99 15.59 2.5 ' / Xb- /8 - 1/2' 23.5 254 273 21 123 0-3.2 330 396 64 10.7 Not available with gap seal Form No. F_020614 16.03.04 Rev 16.1 Replaces form No. F 020614 Rev 15.1 (Reformatting and corrections) I of 2 \ [1 11 GROOVED FITTINGS (. k l:I[qu. MODEL V.7110, V-7111, V.7112, V.7113 y.iy ELBOWS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269.818-1680 Email: techsvcsvikingcorp.com DESCRIPTION VGSO Model V-7110, V-7111, V-7112, and V-7113 Elbows are available in sizes 1-1/4' through 12". Fitting solutions are available in a number of styles and con- figurations to support a variety of applications. VGSI grooved-end fittings are manufactured at 1S09001 certified facilities and are designed to conform to ASTM and other standards where applicable. These products are manufactured and designed to meet ASTM F1548 and ANSl/AWNA C606 requirements for use with grooved mechanical couplings conforming to ASTM F1476. LISTINGS AND APPROVALS c®us Guide No. VIZA Class 1920 TECHNICAL DATA Specifications: Maximum working pressure: 300 psi (21 bar) Ductile iron conforming to ASTM A536 Grade 65-45-12 Coating rust inhibiting paint - Orange RAL 2001 Hot dipped Zinc galvanized versions are available (conforming to ASTM Al 53); when ordering, add a "G" suffix to the Model number. The latest VGS® Technical Data can be acessed at http://www.vikinggroupinc.com. Scan to visit our Mobile website: 1' F http://vikinggroup.mobi/p/46374 CE -L Model V-7110 Model V-7112 90° Elbow 22-1/2° Elbow C-E 1]CE Model V-7111 Model V-7113 45° Elbow 11-1/4° Elbow Model V-711ODR 90° Drain Elbow hlip V.7110 V-7111 V.7112 V.7113 Nominal 90° Elbow 45° Elbow 22.5° Elbow 11.25° Elbow C-E C-E C-E C-E Size Pipe O.D. in (mm) in (mm) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) in (mm) Lbs (Kgs) 1.25 1.66 2.75 1.1 1.75 0.8 1.75 0.64 1.38 0.51 (32) (42) (70) (0.48) (45) (0.37) (45) (0.29) (35) (0.23) 1.5 1.9 2.75 1.3 1.75 (45)E 1.01 1.75 0.97 1.38 0.68 (40) (48) (70) (0.59) (0.45) (45) (0.44) (35) (0.31) 2 2.375 3.25 2 2 1.4 1.89 1.4 1.38 1 (50) 1 (60) (83) (0.89) (51) (0.65) (48) (0.63) (35) (0.45) 2.5 2.875 3.75 2.9 2.25 1.98 2.01 1.83 1.5 1.39 (65) (73) (95) (1.3) (57) (0.9) (51) (0.83) (38) (0.63) 3 3.5 4.25 4.6 2.5 3.2 2.25 2.54 1.5 2.05 (80) (89) (108) (2.1) (64) (1.45) (57) (1.15) (38) (0.93) 4 4.5 5 7 3 4.85 2.87 4.87 1.75 2.78 (100) (125) (127) (3.18) (76) (2.2) (73) (2.21) (45) (1.26) 5 5.563 5.5 9.8 3.25 7.1 (125) (141) (140) (4.42) (83) (3.2) 6 6.625 6.5 13.8 3.5 9.26 3.11 8.89 2 6.04 (150) (168) (166) (6.27) (89) (4.2) (79) (4.03) (51) (2.74) 8 8.625 7.75 27.1 4.25 17.99 3.86 18.19 2 10.54 (200) (219) (197) (12.3) (108) (8.16) (98) (8.25) (51) (4.78) 10 10.75 9 50.6 4.75 32.34 4.37 33.03 2.7 22.8 (250) 1 (273) (229) (23.4) 1 (121) (14.76) (111) (14.98) (68.5) (9.89) 12 12.75 10 75.4 5.25 42.31 (300) (325) (254) 1 (32.2) (133) (19.19) -- FormNo.F_101515 16.12.15 Rev l6.1 Replaces Form No. F_101515 Rev 15.1 (Revised Fig 1) Set Screw and Locknut Included C @ us LISTED 1" 39.7) 3/, (10 Set Sc Locknut Included (22.2) 13/8" (34.9) Beam Clamps - ØTOLCD C®US LISTED Fig. 65 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening Fig. 65X1 - Reversible Steel C-Type Beam Clamp 3/4" (19.0mm) Throat Opening (bottom of page) Size Range: Fig. 65 1/213 rod sizes, and 5/8"-11 rod sizes Fig. 65/XT - I8'-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut Function: Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (19.0mm). Features: All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), pamphlet 13, /8"-16 rod will support 72" (15mm) thru 4" (100mm) pipe 1/2"..13 rod will support thru 8" (200mm) pipe Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number and finish Fig. 65 Patent #4,570,885 Part Rod Size B C D E No. A in. (mm) in. (mm) in. (mm) in. Imnil 65-1/2 1/2"_13 11/2" (38.1) 3/4" (19.0) 1" (25.4) /16" (14.3) 65-I8 /811-11 11/2" (38.1) 3/4" (19.0) 1" (25.4) s/it" (14.3) I Part F Approx. Wt./100 No. in. (mm) Lbs. (kg) 65.1/2 11/4" (31.7) 55 (24.9) 65-5/8 174" (31.7) 55 (24.9) Fig. 65X1-3/8 - Beam Clamp Feature: Extruded holes allows for more thread engagement of threaded rod and set screw. Weight: Approx. Wt./100 - 28.0 Lbs. (12.71-,g) Finish: Plain or Electro-Ga Ivan ized Order By: Figure number and finish Approvals: Underwriters Laboratories Listed (cULus) and FM Approved (FM) for up to 4" 00111n1 pipe. Designed to meet or exceed requirements of FM 05 2-0. Al) d;mensions in charts end on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Fire Protection Solutions 13 B-Line by j3 B A Fig. 2 - Adjustable Band Hanger Size Range - Size 21/2 thru 6" pipe. Material - Carbon Steel, Pre-Galvanized Function - Recommended for the suspension of non-insulated pipe or insulated pipe with Fig. 220 shield. Fig. 2NFPA accommodates the reduced rod schedule of the National Fire Protection Association Pamphlet 13. Approvals - Factory Mutual Engineering approved. Underwriters Laboratories Listed. Conforms to Federal Specification WW-H-1 71 E, Type 10 and Manufacturers Standardization Society SP-69, Type 10. Finish - Pre-Galvanized Note - Available in Stainless Steel materials. Order By - Figure number, pipe size and material C®US LISTED 1 Dimensions • Weights Pipe Max. Rec. Approx. Size Rod Size A B C Load Lbs. Wt./100 21/2 1/2* 53/4 41/ 1/8 600 41 3 1/2k 6 41/8 11/4 600 45 31/2 1/2* 73/8 51/4 21/8 600 52 4 5/8* 73/8 5 15/8 1000 59 5 5/8 9 61/s 21/4 1250 97 6 3/4** 93/8 - 61/2 1/8 1250 139 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5509 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com VK544 VK545 VK546 1, ~fklkx Thread Size K-Factor 1-1/4" NPT (32 mm BSP) 11.2 (161.3 Metric) SIN Style VK544 Plain Barrel VK545 Adjustable Recessed VK546 Adjustable Standard Page 1 of 9 xx STANDARD RESPONSE %II I:Il[su.7M DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Standard Response Dry Pendent Extra-Large Orifice (ELO) Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. These dry pendent ELO sprinklers are FM Approved for storage and non-storage applications. In certain FM cold storage installations, the dry ELO sprinklers can provide a design advantage with lower overall water demands. In these applications, the dry ELO must be installed on a wet pipe system, per FM data sheet 8-9. In non-storage applications, when used in dry or preaction systems, the sprinklers are designed to prevent water or condensation from entering the drop nipple before the sprinkler operates. Viking Standard Response Dry Pendent ELO Sprinklers are available in various finishes and temperature ratings to meet design requirements. The optional dry sprinkler boot assembly is intended to slow the exchange of air between the inside and outside of the freezer (or any dry sprinkler installation) to help prevent humidity and temperature differential in the area around the sprin- kler. Condensation can lead to ice build-up, which could inhibit sprinkler operation or cause premature operation. If using the insulating boot assemblies included with your sprinklers (optional for installation), follow the installation instructions in this technical data page. Insulating boot assemblies, if used, shall be installed on smooth, flat, and clean surfaces. There are specific installation situations, as with corrugated ceiling panels, where alternative penetration sealing methods may be utilized. For additional information contact Viking Technical Services. LISTINGS AND APPROVALS FM Approved: Classes 2013 and 2015 FM Refer to Approval Chart and Design Criteria on page 4 for FM APPROVEP Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1-1/4" NPT or 32 mm BSP Nominal K-Factor: 11.2 U.S. (161.3 metric**) for all listed and approved lengths. * FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). **Metl.ic K-factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass Fusible Link Assembly: Beryllium Nickel, coated with Polyurethane Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass UNS-C36000 Pip Cap Adapter: Brass UNS-C36000 Orifice: Brass UNS-C36000 Tube: ERW Hydraulic Steel Tube Barrel End and Threads: QM Brass Support (Internal): QM Brass Barrel: Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089M/B.) Page 3 of 9 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com TA Ins Size Sprinkler 1: Finishes 2: Temperature Ratings Description Suffix, Nominal Frame Max. Ambient Suffix Model Base Part NPT BSP No. Inch mm Rating4 Paint Color Ceiling Temperature' VK544 19830 1-1/4 -- Brass3 A 165°F(74°C) None 100 "F (38 "C) C 19831 -- 32 Chrome F 205 "F (96 "C) White 150 "F (65 "C) E VK545 19835 1-1/4 -- White Polyester M-/W 280 °F (138 "C) Blue 225 "F (107 "C) G 19836 -- 32 VK546 19840 1-1/4 -- 19841 -- 32 -------- 12(305) -' 18 (457) The "A" Dimension is the distance as S 3. Available "A" Lengths 24 (610) measured from the face of the fitting Inches (mm) 30 (762) in which the sprinkler will be installed A 36 (914) to the face of the finished ceiling in the 42 (1067) protected area. See Figures 2, 3, and 4 48 (1219) Example: 19835FC12 is a VK545 with a Chrome finish and a 165 temperature rating with "A" dimension of 12 inches, This sprinkler is to be installed into an area with a maximum ambient temperature of 100°F (38 °C) meaning if the area will experience temperatures above the maximum ambient rating, you shall use a higher temperature-rated sprinkler. Accessories Sprinkler Wrench: Socket Wrench (for Recessed sprinklers): Part No. 19748W/B - requires a 1/2" ratchet (not available from Viking) Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 19730. Recessed Dry Escutcheon Cup: Base Part No. 19728. Dry Barrel Seals: (NOTE: 2 seals are included with each VK544 and I with each VK545 or VK546) Part No. 22089M/B Footnotes Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. Based on NFPA 13 Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The VK544 is the only sprinkler available with a brass finish. The VK545 is not available with a 280 "F (138 "C) temperature rating. For Standard Adjustable and Plain Barrel sprinklers, use a pipe wrench applied on the inlet housing. Form No. F040815 18.08.02 Rev. 18.1 Page 5 of 9 il STANDARD RESPONSE I:II[.u,YA A DRY PENDENT ! ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinccom For 'A" Dimension: Determine the distance from the face of the tee to the finished ceiling. Round to the nearest 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m). Per "A" dimension, the deflector will be located approximately 4" (102 mm) below the ceiling. 1-1/4" (32 mm) tee NPT (32 mm) Minimum ceiling opening diamter: A —2"(51mm) Maximum ceiling opening diameter: 2-3/8" (61 mm) Finished ceiling (21 mm) Sleeve finish 7 . - matches escutcheon (48 mm) 3-7/8" diameter (99 mm) Deflector at minimum distance below ceiling i NOTE: To locate the F`1 deflector at the minimum Deflector at maximum - distance below the ceiling, distance below ceiling. with no upward NOTE: To locate the adjustment available, deflector at the maximum order the dry pendent distance below the ceiling, 10" sprinkler as per the "A" with no downward dimension. adjustment available, (254 mm) Maximum ....,..order the dry pendent sprinkler 6" (153 mm) / 4" longer than the "A" (102 mm) dimension. - Minimum Figure 2: Adjustable Standard Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 7 of 9 IKr STANDARD RESPONSE 1'% l:II[LuirM DRY PENDENT V ! ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com For "A" Dimension: 1 Determine the distance from the face of the tee to the base of the sprinkler. 2. Round up to the next higher 6" (153 mm) increment between 12" and 48" (305 mm and 1,22 m) - ,,-1-114 (32 mm) tee 1-1/4" NPT (32 mm) — A Outside diamter: 1-11/16" (43 mm) 2-1/16" (53 mm) Figure 4: Plain Barrel Dry Pendent Sprinkler Form No. F_040815 18.08.02 Rev. 18.1 Page 9 of 9 1 I lu STANDARD RESPONSE Ma M 4 l:lI[.u.7M DRY PENDENT ELO SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com ,,- Boot assembly (optional) / Part No. 22089MM (or equivalent method) Clearance opening Insulated ceiling Dry Sprinkler Seal on the Exterior of the ceiling 77 Seal {IIIItIIT1I'I S 7' Insulated ceiling Dry Sprinkler Seal Within the ceiling Figure 6: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_040815 18.08.02 Rev. 18.1 Replaces Form No. F_040815 Rev 16.1 (Revised testing specifications; replaced 19330 with 22089M/B.) Page 2 of 4 Na DRY SPRINKLER %J It" INSULATING BOOT V ASSEMBLIES The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 4. INSTALLATION Prepare the sprinkler installation opening as indicated in the installation instructions on Form No. F_080614 and the appropriate sprinkler technical data page. Then install the dry sprinkler through the clearance opening. Install the dry sprinkler on the piping per the instructions on page Form No. F_080614 and the dry sprinkler data page for the sprinkler model being used, taking care not to over-tighten or damage the sprinkler. Clean the contact surfaces of the dry sprinkler seal and the surface of the wall or ceiling. Slide the dry sprinkler boot over the dry sprinkler barrel and to the ceiling, deck, or wall until the seal rests against the surface of the ceiling, deck, or wall. Assemble the ring onto the seal, hold in place, and tighten the four screws through the holes provided in the assembly. NOTE: A #29 drill is required for a pilot hole in metallic ceilings, decks, or walls. 5. INSPECTIONS, TESTS AND MAINTENANCE A. When replacing existing sprinklers, the system must be removed from service. Refer to the appropriate system description and/ or valve instructions. Prior to removing the system from service, notify all Authorities Having Jurisdiction. Consideration should be given to employment of a fire patrol in the affected area. Remove the system from service, drain all water, and relieve all pressure on the piping. Remove the dry sprinkler boot assembly. Using the special sprinkler wrench, remove the old sprinkler and install the new unit. Care must be taken to ensure that the replacement sprinkler is the proper model and style, with the correct orifice size, temperature rating, and response charac- teristics. A fully stocked spare sprinkler cabinet should be provided for this purpose. Install a new Dry Sprinkler Boot Assembly. Place the system back in service and secure all valves. Check the replaced sprinklers and repair all leaks. B. Sprinkler systems that have been subject to a fire must be returned to service as soon as possible. The entire system must be inspected for damage and repaired or replaced as necessary. Sprinklers that have been exposed to corrosive products of combus- tion, but have not operated, should be replaced. Refer to the Authorities Having Jurisdiction for minimum replacement requirements. AVAILABILITY The Viking products are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Under Seal Ring #10 Tapping Screw ED • For 22087MN: Fits 1-5/16" Seal t (33 mm) O.D. Barrel 6" (152 mm) 1" (43 mm) O.D. Barrel I (25 mm) For 22089MM!: Fits 1-11/16" Over Seal Ring I Figure 1: Dry Sprinkler Insulating Boot Dimensions Form No. F030107 18.08.02 Rev 18.1 Page 4 of 4 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com #10 TAPPING SCREW OVER SEAL RING Seat UNDER SEAL Opening Ceiling Structure STEP 1 INSTALL SEAL AROUND BARREL OF DRY SPRINKLER WOOD - NO PILOT HOLE REQUIRED :TAL - DRILL PILOT HOLE FOR SCREWS Clearance Opening Insulated Ceiling Structure STEP Z PLACE SEAL FLUSH WITH TOP OF FREEZER AND SECURE AROUND BARRELL All Clearance Opening VT n sulo~. 7te d Ceiling Structure STEP 4 SECURE INSULATING RING TO TOP OF FREEZER WITH #10 TAPPING SCREWS Figure 3: Dry Sprinkler Insulating Boot Assembly - Installation Sequence (Dry Pendent Sprinkler Shown) Form No. F_030107 18.08.02 Rev 18.1 Replaces Form No. F_030 107 Rev 16.1 (Replaced 1933OMiW with 22089M1W and 19398M/B with 22087M/B) Page 2 of 6 FY MICROFASTI& QUICK SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 10896W/B (available since 2000). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051 808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 197 1) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Clip fl Wrench Flat Protective Sprinkler Cap Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F033314 16.01.28 Rev 16.1 Page 4 of 6 MICROFAST@ QUICK RESPONSE PENDENT " J SPRINKLER VK3O2(K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Appro-~,al Chart 1, (UL) II', VUig !cofcc Quc R.cponc . Pndnt Sprin!Uer V302 AX4 u. ns mum1Th PSI t12 Ur) tp - Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric' Inches I mm cULus4 VdS LPCB (E (. 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z,B1Y D1Z, C1Y -- D3Z 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1\ D2, C2X -- -- -- -- I 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AiX, B1Y Al AiX, BiY D1X. dY0 Dix, CiY -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135 OF (57 °C), 155 OF (68 "C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 "C), 200 OF (93 "C), 286 OF (141 °C) Polyester56, Black Polyes- Viking Micromatic5 Model E-1 Recessed Escutcheon B - 135 OF (57 "C), 155 OF (68 "C), 175 OF ter56 Y - Standard surface-mounted escutcheon or the (79 "C), and 200 OF (93 °C) 2 - ENT5 Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 OF (68 "C). 175 OF (79 "C), and 3-Chrome rnatiOt Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 "C) Z - Standard surface-mounted escutcheon or the D - 155 OF (68 °C), 175 OF (79 "C), 200 OF Viking Microfast Model F-i Adjustable Escutcheon (93 "C), 286 OF (141 "C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc for use in the U.S. and Canada cULus Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. CE Certified, Standard EN 12259-1, Ed-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1 003 and 0832-MED-1 008. DESIGN CRITERIA - UL (Also refer to Approval Chart I above) cULus Listing Reguirements: The Viking Microfaste Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. If Form No. F_033314 16.01.28 Rev 16.1 1-1/8" .6 mm) Mm. Li— 2-1/8" (54 mm) 2 (5n) Max. JT1 L,- 2-1/8" - (54 mm) 1-3/4" (44.5 mm) Max. - Ceiling Opening Size: 2-5-16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum , 1-1/8" (28.6 mm) Mm. Page 6 of 6 /7 [17 R: MICROFAST® QUICK RESPONSE PENDENT flflflj SPRINKLER VK3O2(K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Ji Ceiling Opening Size: i 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum (15 mm) NPT I 1.4 (54mm) r- ,; , ) . (4:mm) 'L j(81/2) Installed with a standard Installed with a Microfast Note: At maximum, adapter is 1/8" surface-mounted Model F-I Adjustable exposed 1/2" (12.7 mm) from escutcheon Escutcheon face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 16.01.28 Rev 16.1 Replaces Form F_0333314 Rev 15.2 (Revised temperature suffix designation)