Loading...
HomeMy WebLinkAbout2628 GATEWAY RD; E; FPC2018-0130; PermitCi ty of Carlsbad Print Date: 02/10/2022 Permit No: FPC2018-0130 Job Address: 2628 GATEWAY RD, CARLSBAD, CA 92009-1776 Status: Closed- Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132621900 Track #: Applied: 05/04/2018 Valuation: $0.00 Lot #: Issued: 05/30/2018 Occupancy Group: Project #: DEV12023 Finaled Close Out: 05/25/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: UPTOWN BRESSI RANCH Description: THE SQUARE AT UPTOWN BRESSI -BUILDING E -SPRINKLER (94 HEADS) Applicant: FPContractor: LINDLEY FIRE PROTECTION LINDLEY FIRE PROTECTION CO INC-DO NOT JAVIER MEJIA USE 2220 E VIA BURTON 1109 N ARMANDO ST ANAHEIM, CA 92806-1221 ANAHEIM, CA 92806-2609 (714) 984-4150 (714) 535-5761 FEE AMOUNT FIRE NFPA 13 System < 100 heads $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F~w - Fire Protection by Computer Design LINDLEY FIRE PROTECTION 2220 E. VIA BURTON ANAHEIM, CA 92806 714-535-5761 Job Name : THE SQUARE AT BRESSI RANCH BLDG E Building : E Location : 2628 GATEWAY ROAD System 1 Contract : A3001 Data File : The Square at Bressi Ranch Bldg E.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 LINDLEY FIRE PROTECTION Page THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 Hydraulic Design Information Sheet Name - THE SQUARE AT BRESSI RANCH BLDG E Date - 4-27-18 Location - 2628 GATEWAY ROAD Building - E System No. - 1 Contractor - CSI CONTRUCTION COMPANY Contract No. - A3001 Calculated By - T. OMORI Drawing No. - FPE2.0 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - 191 -e" Occupancy - RETAIL (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. ( ) 1 (X) 2 C ) 3 ( ) Ex.Haz. NFPA 231 ( ) NFPA 231C Figure Curve Other Specific Ruling Made By Date Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .20 (X) Wet Make GLOBE Area Per Sprinkler - 111 C ) Dry Model GL Elevation at Highest Outlet - 18 1 -8" ( ) Deluge Size 1/2 Hose Allowance - Inside - 100 ( ) Preaction K-Factor 5.6 Rack Sprinkler Allowance - C ) Other Temp.Rat.200 Hose Allowance - Outside - 150 Note Calculation Flow Required Summary C-Factor Used: - 423.78 Press Required - 120 Overhead 61.773 BOR 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 3-9-18 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 129 @ Press - R Residual Press - 20 Elev. - Well Flow - 8000 Proof Flow S Elevation - U P Location - EL FUERTE STREET NORTH OF GATEWAY ROAD P L Source of Information - CITY OF CARSBAD Y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M Single Row C ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row C ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: S Y S T E M D E S I G N Water Supply Curve C LINDLEY FIRE PROTECTION Page 2 THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 City Water Supply: Demand: Cl - Static Pressure : 129 Dl - Elevation : 8.085 C2 - Residual Pressure: 20 D2 - System Flow : 423.778 C2 - Residual Flow : 8000 D2 - System Pressure : 67.865 Hose ( Demand) : 250 D3 - System Demand : 673.778 Safety Margin : 60.014 150 Cl 140 130 120 R 110 E 100 90 S80 - D2 U 70 R60 D E5° 40 --- 30 - C2 20 I.J.,91,dercentUnder. 10 -- 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW ( N 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 flow Diagram LINDLEY FIRE PROTECTION THE SQUARE AT BRESSI RANCH BLDG E 19.8 AO - AOl 22.2 A02*- A03 Page 3 Date 4-27-18 20.4 61.4 105.5 155.2 1 2 -3 '-4 (-5 4-6 4-7 4-8 40.8 83.2 129.3 t I 155.2 21 63.4 107.2 159.9 9 4-10 +- 11 +-12 +-13 (-14 4-15 +_16 42.1 85 131 27.4 82.9 17 - 18 - 19 - 20 - 21 55 111.6 155.2 423.8 423.8 523.8 523.8 673.8 214.2 214.2 8 4-16 4-21 4-22 4-23 312.2 423.8 423.8 523.8 523.8 214.2 214.2 214.2 459.6 UG4(- UG9(- CON 673.8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary LINDLEY FIRE PROTECTION THE SQUARE AT BRESSI RANCH BLDG E Page Date 4 4-27-18 Fitting Legend Abbrev. Name ½ 3h 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 F NFPA 139O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 139OFlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zif Febco 876V Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs 1 'Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD LINDLEY FIRE PROTECTION Page 5 THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. AO 18.667 5.6 12.5 na 19.8 0.2 99 7.0 AOl 18.667 14.03 na A02 18.667 5.6 15.72 na 22.2 0.2 111 7.0 A03 18.667 17.6 na 1 18.667 K= K@AOI 14.84 na 20.36 2 18.667 K= K@AOI 14.93 na 20.43 3 18.667 K= K@AO1 15.26 na 20.65 4 18.667 K= K@AO1 16.89 na 21.73 5 18.667 K= K@A03 17.75 na 22.29 6 18.667 K= K @A03 20.31 na 23.84 7 18.667 K= K@A03 24.04 na 25.94 9 18.667 K= K@AO1 15.79 na 21.0 10 18.667 K=K@AOI 15.88 na 21.07 11 18.667 K=K@AO1 16.23 na 21.3 12 18.667 K=K@AOI 16.71 na 21.61 13 18.667 K= K@A03 17.6 na 22.2 14 18.667 K= K@A03 20.24 na 23.8 15 18.667 K= K@A03 24.06 na 25.95 17 18.667 K= K@AO1 26.95 na 27.44 18 18.667 K= K@A03 27.06 na 27.52 19 18.667 K= K@A03 27.83 na 27.91 20 18.667 K= K@A03 29.46 na 28.72 8 18.667 33.69 na 16 18.667 33.9 na 21 18.667 34.7 na 22 18.667 38.68 na 23 18.667 48.57 na TRE 18.667 50.1 na BRE 0.0 61.77 na 100.0 El 0.0 62.01 na E2 0.0 62.48 na E3 0.0 66.56 na UG3 0.0 67.13 na 150.0 UG4 0.0 67.36 na UG5 0.0 67.48 na UG6 0.0 67.53 na UG7 0.0 67.6 na UG8 0.0 67.66 na UG9 0.0 67.74 na CON 0.0 67.86 na The maximum velocity is 21.18 and it occurs in the pipe between nodes 15 and 16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 6 THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C'.or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn AO 19.80 1.087 2T 11.892 2.333 12.501 K Factor 5.60 to 120.0 0.0 11.892 0.0 AOl 19.8 0.1074 0.0 14.225 1.528 Vel = 6.85 0.0 19.80 14.029 K Factor = 5.29 A02 22.20 1.087 2T 11.892 2.333 15.716 K Factor = 5.60 to 120.0 0.0 11.892 0.0 A03 22.2 0.1327 0.0 14.225 1.888 Vel = 7.68 0.0 22.20 17.604 K Factor = 5.29 1 20.36 1.74 0.0 8.000 14.839 K Factor @ node AOl to 120.0 0.0 0.0 0.0 2 20.36 0.0114 0.0 8.000 0.091 Vel = 2.75 2 20.43 1.74 0.0 8.000 14.930 K Factor @ node AOl to 120.0 0.0 0.0 0.0 3 40.79 0.0414 0.0 8.000 0.331 Vel = 5.50 3 20.65 1.74 2E 11.677 6.792 15.261 K Factor @ node AOl to 120.0 0.0 11.677 0.0 4 61.44 0.0883 0.0 18.469 1.631 Vel = 8.29 4 21.73 1.74 0.0 5.542 16.892 K Factor @ node AOl to 120.0 0.0 0.0 0.0 5 83.17 0.1545 0.0 5.542 0.856 Vel = 11.22 5 22.29 1.74 0.0 10.667 17.748 K Factor @ node A03 to 120.0 0.0 0.0 0.0 6 105.46 0.2398 0.0 10.667 2.558 Vel = 14.23 6 23.84 1.74 0.0 10.667 20.306 K Factor@ node A03 to 120.0 0.0 0.0 0.0 7 129.3 0.3497 0.0 10.667 3.730 Vel = 17.45 7 25.94 1.74 1 11.677 8.000 24.036 K Factor @ node A03 to 120.0 0.0 11.677 0.0 8 155.24 0.4904 0.0 19.677 9.650 Vel = 20.95 0.0 155.24 33.686 KFactor 26.75 9 21.00 1.74 0.0 8.000 15.786 K Factor @ node AOl to 120.0 0.0 0.0 0.0 10 21.0 0.0121 0.0 8.000 0.097 Vel = 2.83 10 21.07 1.74 0.0 8.000 15.883 K Factor @ node AOl to 120.0 0.0 0.0 0.0 11 42.07 0.0438 0.0 8.000 0.350 Vel = 5.68 11 21.30 1.74 0.0 5.125 16.233 K Factor @ node AOl to 120.0 0.0 0.0 0.0 12 63.37 0.0935 0.0 5.125 0.479 Vel = 8.55 12 21.61 1.74 0.0 5.542 16.712 K Factor @ node AOl to 120.0 0.0 0.0 0.0 13 84.98 0.1610 0.0 5.542 0.892 Vel = 11.47 13 22.20 1.74 0.0 10.667 17.604 K Factor @ node A03 to 120.0 0.0 0.0 0.0 14 107.18 0.2471 0.0 10.667 2.636 Vel = 14.46 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 7 THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 14 23.80 1.74 0.0 10.667 20.240 K Factor @ node A03 to 120.0 0.0 0.0 0.0 15 130.98 0.3581 0.0 10.667 3.820 Vel = 17.67 15 25.96 1.74 T 11.677 8.000 24.060 K Factor @ node A03 to 120.0 0.0 11.677 0.0 16 156.94 0.5003 0.0 19.677 9.845 Vel = 21.18 0.0 156.94 33.905 KFactor= 26.95 17 27.44 1.74 0.0 5.542 26.949 K Factor @ node AOl to 120.0 0.0 0.0 0.0 18 27.44 0.0198 0.0 5.542 0.110 Vel= 3.70 18 27.53 1.74 0.0 10.667 27.059 K Factor @ node A03 to 120.0 0.0 0.0 0.0 19 54.97 0.0719 0.0 10.667 0.767 Vel = 7.42 19 27.91 1.74 0.0 10.667 27.826 K Factor @ node A03 to 120.0 0.0 0.0 0.0 20 82.88 0.1536 0.0 10.667 1.638 Vel = 11.18 20 28.72 1.74 T 11.677 8.000 29.464 K Factor @ node A03 to 120.0 0.0 11.677 0.0 21 111.6 0.2662 0.0 19.677 5.239 Vel= 15.06 0.0 111.60 34.703 KFactor= 18.94 8 155.24 3.316 0.0 10.333 33.686 to 120.0 0.0 0.0 0.0 16 155.24 0.0212 0.0 10.333 0.219 Vel = 5.77 16 156.94 3.316 0.0 10.333 33.905 to 120.0 0.0 0.0 0.0 21 312.18 0.0772 0.0 10.333 0.798 Vel = 11.60 21 111.60 3.316 T 21.903 7.333 34.703 to 120.0 0.0 21.903 0.0 22 423.78 0.1360 0.0 29.236 3.976 Vel = 15.74 22 0.0 3.316 E 10.221 62.542 38.679 to 120.0 0.0 10.221 0.0 23 423.78 0.1360 0.0 72.763 9.894 Vel = 15.74 23 0.0 3.316 E 10.221 1.042 48.573 to 120.0 0.0 10.221 0.0 TRE 423.78 0.1359 0.0 11.263 1.531 Vel = 15.74 TRE 0.0 4.316 Fsp 0.0 15.500 50.104 to 120.0 0.0 0.0 11.085 * * Fixed Loss = 3 BRE 423.78 0.0377 0.0 15.500 0.584 Vel = 9.29 BRE 100.00 6.357 E 17.603 10.000 61.773 Qa = 100 to 120.0 0.0 17.603 0.0 El 523.78 0.0084 0.0 27.603 0.233 Vel = 5.29 El 0.0 6.09 2E 43.166 26.000 62.006 to 150.0 0.0 43.166 0.0 E2 523.78 0.0069 0.0 69.166 0.477 Vel = 5.77 E2 0.0 6.16 Zif 0.0 10.000 62.483 to 140.0 0.0 0.0 4.000 * * Fixed Loss = 4 E3 523.78 0.0075 0.0 10.000 0.075 Vel = 5.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams LINDLEY FIRE PROTECTION Page 8 THE SQUARE AT BRESSI RANCH BLDG E Date 4-27-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn E3 0.0 6.09 G 4.625 11.000 66.558 to 150.0 T 46.249 72.457 0.0 UG3 523.78 0.0069 E 21.583 83.457 0.575 Vel = 5.77 UG3 150.00 7.98 F 13.591 58.500 67.133 Qa = 150 to 150.0 G 6.041 19.632 0.0 UG4 673.78 0.0029 0.0 78.132 0.230 Vel = 4.32 UG4 -459.61 7.98 E 27.183 234.500 67.363 to 150.0 F 13.591 99.669 0.0 UGS 214.17 0.0004 G 6.041 334.169 0.119 Vel = 1.37 T 52.855 UGS 0.0 7.98 3F 40.774 94.000 67.482 to 150.0 0.0 40.774 0.0 UG6 214.17 0.0003 0.0 134.774 0.047 Vel = 1.37 UG6 0.0 7.98 2F 27.183 187.000 67.529 to 150.0 0.0 27.182 0.0 UG7 214.17 0.0004 0.0 214.182 0.076 Vel = 1.37 UG7 0.0 7.98 2F 27.183 124.500 67.605 to 150.0 0.0 27.182 0.0 UG8 214.17 0.0004 0.0 151.682 0.054 Vel= 1.37 UG8 0.0 7.98 F 13.591 155.000 67.659 to 150.0 C 6.041 72.487 0.0 UG9 214.17 0.0004 T 52.855 227.487 0.080 Vel = 1.37 0.0 214.17 67.739 KFactor= 26.02 UG4 459.60 7.98 F 13.591 233.000 67.363 to 150.0 2G 12.081 25.674 0.0 UG9 459.6 0.0015 0.0 258.674 0.376 Vel = 2.95 UG9 214.18 11.65 2F 34.882 138.000 67.739 to 150.0 2G 16.1 131.481 0.0 CON 673.78 0.0005 T 80.498 269.481 0.126 Vel = 2.03 0.0 673.78 67.865 KFactor= 81.79 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: The Square at Bressi Ranch SR#: (Assigned upon plan submittal) PROJECT ADDRESS: CITY: Carlsbad PHONE: ( ) Lindley Fire FAX NUMBER: Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): El Fuerte St north of Gateway Rd Flow Test Results Static pressure: 129 PSI Hydrant Number (if applicable):H20910 Elevation of test: 402 Feet Main Size: 24 INCH Pressure Zone: 700 Feet ]touReadingP Total Flow: 8.000 GPM Residual Pressure 110 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi in excess of 8,000 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable):C69606 Signature:________________________________________ Title/Org:'oiect Manager Date: 03/09/2018 8' ______'C + Legend w_Hydrant Pipe ZONE 550 8 700 I all 12" OD CO T. LEIGHTON CR 8ll DRTINGTON WY CD LU ALAMEDA CR HANCOCK CR 0 lof Fire Flow Test ( i Location H20910 12 Project Site 12' 1 12 12 The Square at Bressi Ranch - Fire Flow Analysis ES-F-LF876V Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative MasterSeries® LF876V Double Check Detector Backflow Prevention Assemblies (Type II) Size: 21/2" - 8" (65mm - 200mm) The FEBCO MasterSeries LF876V Double Check Detector Assembly is specifically designed to protect against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application in accordance with Local Governing Water Utility Code. This Backflow Assembly is primarily used on potable drinking water systems and fire sprinkler systems, where Local Governing Code mandates protection from non-potable quality water being pumped or siphoned back into the potable water system. Features Main Valve: Inline Serviceable Assembly Horizontal 'N-Pattern" Installations Vertical-Up "Z-Pattern" Installations No Special Tools Required for Servicing Captured Modular Spring Assembly Reversible & Replaceable Discs Field Replaceable Seats Ductile Iron Valve Body Design Stainless Steel Check Components Winterization feature with disc retainers and valve body drain ports Clapper Check Assembly Commonality between 1St & 2nd Check Components Captured 0-ring Design Auxiliary Bypass: Compact Bypass Design; Remains within Main Valve Assembly Profile Inline Serviceable 3/4' Backflow Assembly No Special Tools Required for Servicing Field Replaceable Seats & Discs Detect Potential Underground Water Leaks Detect Unauthorized Water Usage Model LF876V Double Check Detector Assembly Specifications The FEBCO MasterSeries LF876V Double Check Detector Valve Assembly shall be installed on the potable water supply and at each point of cross-connection to protect against possible backpressure and backsiphonage conditions for non-heafth hazard (i.e., pollutant) applications. The assembly shall consist of a main line valve body composed of two (2) independently acting approved clapper style check modules with replaceable seats and disc rubbers. Servicing of both check modules does not require any special tools and are accessed through independent top entry covers. This assembly shall be fitted with approved UL/ FM inlet/outlet resilient seated shutoff valves and contain four (4) properly located resilient seated test cocks as specified by A\MNA Standard 0510. The auxiliary bypass line contains a 5/8 'x3/4" Water Meter that complies with ANSI/A\NWA Standard C700 coupled with an approved check assembly. The bypass line is designed to detect leaks or unauthorized water usage of the water system while protecting against possible backpressure and backsiphonage conditions for non-health hazard (i.e., pollutant) application. The assembly shall be approved for horizontal and/or vertical-up installations while meeting the requirements of A\fWVA Standard C51 0 flow and pressure loss performance parameters. i'iIitI?i The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. i![IIIfl Inquire with governing authorities for local installation requirements *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. FEBCO product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, /ff® please contact FEBCO Technical Service. FEBCO reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without incurring any obligation to make such changes and modifications on FEBCO products previously or subsequently sold. A WATTS Brand Options - Suffix OSY: UL/FM Approved OS&Y Gate Valves [ANSI/AVVWA 0515 Compliant] CFM: Totalizing Cubic feet/mm 5/8'x 3/4" Water Meter [ANSI! AVW/A 0700 Compliant] GPM: Totalizing Gallons/mm 5/8'x 3/4" Water Meter [ANSI! AVWIA 0700 Compliant] LG: Less Shutoff valves; This is NOT an APPROVED ASSEMBLY Example Ordering Description: 4 LF876V-OSY-GPM - Valve Assembly fitted with OS&Y Shutoff Valves & Gallons per Minute Water Meter 4 LF876V-OSY-CFM - Valve Assembly fitted with OS&Y Shutoff Valves & Cubic Feet per Minute Water Meter Available Components Wye Strainer. FDA Approved [ASME B16.1 Class 125 & AV\iWA Class D Flange] Series 611 Valve Setter: MJ x MJ - Mechanical Joint x Mechanical Joint [A\AANA Cli 1!A21.1 1] MJ x FL - Mechanical Joint x Flange [AW\NAC111/A21.11; ASME 816.1 Class 1 25/A\MNA Class D Flange] FL x FL - Flange x Flange [ASME Bi 6.1 Class 125 & AWNA Class D Flange] Matenals Below is a general materials list of the Model LF876V. All assemblies size 21/2' through 8' is similar in materials and construction. Please contact your local FEB00 Representative if you require further information. Main Valve Body: Ductile iron Grade 65-45-12 Coating: Fusion epoxy coated internal and external AW/A 0550-90 Shutoff Valves: OSY resilient wedge gate valve A\MNA 0515 (UL/FM) Check Seats: Stainless Steel Disc Holder: Stainless Steel Elastomer Disc: Silicone Spring: Stainless Steel Clamp: AW/VA 0606 Approvals - Standards: Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The University of Southern California [F000HR-USC[ ASSE 1048 Listed **UL Classified [US & Canada] **FM Approved IAPMO/cUPC AWWA Standard 0510 Compliant End Connections: Compliant to ASME 1316.1 Class 125 & AV\N\/A Class D Flange **Assembly configured with UL/FM Approved OS&Y RW Gate Valves. Less gate valve assemblies are not UL/FM approved configurations. Assembly Flow Orientation: Horizontal (N-Pattern 21/2" - 8") - Approved by F000HR-USC, ASSE, cULus, FM, lAPMO/cUPC Vertical Up (Z-Pattern 21/2" - 8") - Approved by F000HR-USC, ASSE, cULus, FM, IAPMO/cUPC ® ® ssIp,.* Approved C®US C ® 1048 B64.5 Pressure - Temperature Max. Working Pressure: 175psi (12.1 bar) Mm. Working Pressure: lOpsi (0.7 bar) Hydrostatic Test Pressure: 350psi (24.1 bar) Hydrostatic Safety Pressure: 700psi (48.3 bar) Temperature Range: 33°F - 140°F [0.5°C- 60°C] Continuous In Dimensions - Weights Size: 21/2" - 8" Below are the nominal dimensions and physical weights for the Model LF876V size 2112" through 8'. Allowances must be made for normal manufacturing tolerances. Please visit our website to download a copy of this product's installation instructions, or contact your local FEB00 Representative for more information. Model LF876V Standard Orientation (N-Pattern) Model LF876V Vertical Orientation (Z-Pattern) Note: The Series LF876V is shipped in the standard (N-Pattern) orientation as shown above. Gate Valve Side View Clearance LF876V SIZE (DN) DIMENSIONS WEIGHT in. mm A in. mm B in. mm in. C mm 0 in. mm E in. mm F in. mm in. G mm in. H mm in. I mm J in. mm in. mm in. L mm OSY lbs. kg. 21/2 65 291/8 740 121/2 318 61/4 159 251/4 642 171h 445 135/8 346 271/4 692 51/2 140 111/8 283 31/2 89 16V8 416 111/2 292 216 98 3 80 291A 740 121/2 318 61/4 159 253/4 654 173/4 451 141/a 359 281/4 718 51/2 140 11½ 283 33/4 95 221/4 565 11½ 292 242 110 4 100 311/8 791 14 356 7 178 273/4 705 183/4 476 151/2 394 31 787 6 152 111/8 283 41/2 114 231/4 591 13 330 347 157 6 150 353/4 908 16 406 8 203 323/4 831 221/8 562 185/8 473 371/4 946 71/4 184 12112 316 51/2 140 301/8 765 13 330 529 240 8 200 40/4 1035 18½ 470 91/4 235 36~ 933 25½ 638 203/4 527 41½ 1054 8½ 216 14 356 63/4 172 373/4 959 14½ 368 827 375 Notes: * Indicates nominal dimensions with OSY Gate Valves (Full Open Position) Indicates weight of complete Backflow Assemblies with specified Gate Valves 6" LF876V psi Service Flow Rated Flow *UL Rated Flow 18 16 14 I I I I I 12 I I I I 10go I o 200 400 757 600 800 1000 1200 2271 3785 7.5 11.4 1400 1600gpm 5300 1pm 17.0 fps 8" LF876V PSI Service Flow Rated Flow *01 Rated Flow 18 16 14 a 12 10 m 8 0 400 800 1200 1600 2000 2400 gpm 1514 3028 4543 6057 7571 9085 1pm 7.5 10.5 15.3 fps Performance Flow capacity chart identifies valve performance based upon rated water Velocity up to 20fps Maximum service flow rate is determined by maximum rated Velocity of 7.5fps. AW\NA Manual M-22 (Appendix C) recommends that the maximum water Velocity in the services be not more than 1 Ofps. UL flow rate is determined by typically rated Velocity of 15 feet/sec. Capacity N-Pattern 2½" LF876V PSI Service Flow Rated Flow 01 Rated Flow 22 I I I I 20 I I 18 I 16 I 14 I I 2 12 I I I 10 I I 8 - 6 r- 4 I I 2 I 0 L 1 0 25 50 75 100 125 150 175 200 225 250 275 300 325 350gpm 284 568 852 1136 1pm 7.5 14.7 22.0 fps psi LF876V Service Flow Rated Flow "UL Rated Flow 22 20 I I I 18 I I I ' 16 I I I .S 14 I I 5 E, 12 10 6 4 - ---:- 2 0 0 50 100 379 LF876V psi 150 200 250 757 7.5 Service Flow 300 350 1136 14.5 Rated Flow 400 450 500 gpm 1514 1pm 22.0 fps *UL Rated Flow 18 I I I I 16 I 14 I I I I I I 00 a.! 12 10 I 2 I I Vi : - 4 I I 2 I I 0 I I I I I 0 100 200 300 400 379 1136 7.5 500 600 1893 12.8 700 800gpm 2650 1pm 19.1 fps Pipe Support (furnished by customer) for valve weight only. Vertical Orientation"Z-Pattern" Flow Curve Z Standard Orientation"N-Pattern" Flow Curve N A WATTS Brand ES-F-LF876V 1515 USA: Tel: (800) 767-1234 • Fax: (800) 788-4491 • FEBCOonline.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • FEBcoonline.ca Latin America: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • FEacoonline.com 0 2017 FEBCO ECS Ejector Automatic Air Vent (PAV-W) E] 1 OR EEI Specifications Stock Number: PAV-W [mile' PAV-WS (Supervised) Service Pressure: Up to 175 PSIG System Connection: 1" NPT Male Temperature Range: 40°F to 120°F (4.5°C to 49°C) Dimensions: 14"(L) X 7"(D) X 7"(H) Weight: 8 Lbs Clear Height: 5" Patented redundant float design eliminates piping to a drain Support Hanger Not Required U.S. Pat. No. 8,636,023 General Description The ECS Ejector Automatic Air Vent (PAV-W/WS) is a device that provides automatic venting of trapped air in wet pipe fire sprinkler systems. As a fire sprinkler system is filled with water, trapped air migrates to the high point of the system near the vent installation location which allows for trapped air to be vented. Trapped air contains oxygen which is the primary cause of corrosion in fire sprinkler systems. Corrosion in wet pipe fire sprinkler systems is directly proportional to the amount of oxygen trapped within the system piping, so a reduction in trapped air will in turn reduce the internal corrosion activity of the fire sprinkler system. Venting the trapped air in a wet pipe sprinkler system can also decrease water delivery time and reduce false water flow alarms. The ECS Ejector Automatic Air Vent must be installed as shown on the engineering design documents, if a location is not provided install the vent at an accessible high point on the fire sprinkler system remote from the system riser where gas can be vented and at a location that the pressure gauge provided for visual monitoring can be viewed from directly below. The PAV-W/WS is also equipped with brass components that allows the device to be installed in areas subject to external corrosion. The float mechanism on the ECS Ejector Automatic Air Vent will automatically close when water reaches the vent and the redundant design eliminates the need to plumb the PAV-W/WS to drain. If the primary air vent valve allows any significant amount of water to leak past the second air vent valve will close preventing water from discharging and provide a system pressure reading on the pressure gauge. This condition will be an indication that the primary automatic gas vent valve has failed and requires service or replacement. The pressure gauge is designed to be visible from the floor below the ECS Ejector Automatic Air Vent from a distance of approximately 30 feet. There are two available models of the ECS Ejector Automatic Air Vent: the PAV-W and the PAV-WS. The units both operate as described previously, but the PAV-WS includes a wiring connection to a monitoring circuit. A single contact rated 24VAC/DC @ 2A for electronic monitoring with an end of line resistor (EOLR) must be installed according to the wiring diagram in Figure 1 to electronically monitor the PAV-WS. A notification from the PAV-WS indicates that the pressure gauge on the bottom of the vent assembly has a system pressure reading due to a failure of the primary float valve which renders the ECS Ejector Automatic Air Vent inoperable. Engineered Corrosion Solutions11336 Lackland RoadS St. Louis, MO 63146 Phone 1-314-432-1377W www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT _b13& 16 1 3 1 Installation Instructions Maintenance Instructions 1 The ECS Ejector Automatic Air Vent is equipped with an isolation ball valve to be connected to the fire sprinkler system. Once the PAV-W/WS has been assembled at the provided union (see Figure 1), the contractor shall install a 1" outlet (welded or mechanical) to connect the vent assembly to the sprinkler system. 2. Install the PAV-W/WS vent assembly at the location provided by the engineering design documents in a level position at an accessible high point on the sprinkler system where trapped gas can be vented. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. 3 When electronic supervision is specified the PAV-WS must be utilized instead of the PAV-W (see Figure 1) and an addressable monitor module with an end of line resistor must be provided in accordance with NFPA 72. 4 Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. Inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. NOTE: Patented redundant float design eliminates piping the PAV-W to a drain FIGURE 1 — Wiring Diagram INSTALLATION NOTES: If Monitored By The Building Fire Alarm System, Provide One Addressable Monitoring Module To Monitor The Ejector Automatic Air Vent. Connect The Ejector Automatic Air Vent To The Addressable Monitor- ing Module. Supervise The Circuit Using An End-Of -Line (E.O.L.) Resistor In Accordance Add, eabI With NFPA 72. RNMIN The ECS Ejector Automatic Air Vent shall be inspected annually at minimum. While isolation ball valve is in the open position check for air/water leaks. Check the pressure gauge on the bottom of the vent assembly for a system pressure reading. If a system pressure reading is detected the primary vent valve may require service or replacement. While isolation ball valve is in the closed position the inspection must check for blockage in the "Y" strainer and the discharge orifice. Oøeratine Instructions Once the fire sprinkler system has been hydrostatically tested, open the isolation ball valve on the PAV-W. Trapped gas should be expected to immediately vent from the device if the system has been re-filled with water. The isolation ball valve shall remain in the open position to allow for venting of any additional trapped gas remaining in the system that may migrate to the vent location. Water traps that would restrict operation of the ECS Ejector Automatic Air Vent can be cleared by closing the isolation ball valve and removing the "Y" strainer plug. Once the water trap has been removed, replace the "'i" strainer plug and reopen the isolation ball valve. Gas Vent Valve Replacement Plumbing the PAV-W/WS to drain is not required. Occasionally during venting operations a small amount of water may leak past the primary gas vent valve and collect in the intermediate plumbing. This is considered normal and not a failure of the valve. However, if inspection reveals a system pressure reading then the primary vent valve may require replacement. Please contact Engineered Corrosion Solutions for replacement parts and instructions. Engineered Corrosion Solutions• 11336 Lackland Road St. Louis, MO 63146• Phone 1-314-432-1377• www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 2 1" Connection to Sprinkler System must NOTE: Patented redundant float design eliminates piping vent to drain. Figure 2 - ECS Ejector Automatic Air Vent Outline Drawing Primary and Seconda Gas Vent Valves "Y" Strair Pressure Gauge Figure 3 - ECS Ejector Automatic Air Vent Installed on Sprinkler System NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. Engineered Corrosion Solutions- 11336 Lackland Road • St. Louis, M063146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 En g'ina8ra .1 TM ECS C;O rros'Pa ln k, Sqn* I [Lei Iti 11#1ns Complete Corrosion Control. L 6 _ INDLEY LINDLEY FIRE PROTECTION CO. 2220 E. VIA BURTON ANAHEIM, CA 714-535-5761 LIC. # C16/C34 NO. 713562 DATE: 4-27-18 MATERIAL SUBMITTAL FOR THE SQUARE AT BRESSI RANCH BUILDING E 2628 GATEWAY ROAD CARLSBAD, CA STANDARD RESPONSE AUTOMATIC SPRINKLERS UUWW (fan ___ __ CL SERIES UPRIGHT 'PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Standard Response GL Series Sprinklers are a low profile yet durable design which utilizes a 5mm frangible glass ampule as the thermosensitive element. While the Standard Response Sprinkler provides an aesthetically pleasing appear- ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and fin- ishes to meet varying design requirements. Standard Response STANDARD RESPONSE Sprinklers should be used advisedly and under the direction of UPRIGHT CONVENTIONAL approving authorities having jurisdiction. I, The heart of Globe's GL Series sprinkler proven actuating - assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. STANDARD RESPONSE The sprinkler and escutcheon are not factory assembled. PENDENT VERTICAL Assembly is done in the field. SIDEWALL TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (79°C), 200°F (930C), 286°F (141°C), 360°F (182°C) 500°F (260°C) Available Upon Request Without Approvals / Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) STANDARD RESPONSE Maximum low temperature glass bulb rating is -67°F (-55°C) LPC/CE HORIZONTAL Frame - bronze • Deflector - brass • Screw - brass HORIZONTAL SIDEWALL Lodgement Wire - stainless steel• Bulb seat - copper SIDEWALL Spring - nickel alloy • Seal - teflonw Bulb - glass with glycerin solution, 5mm size Escutcheon Assembly - steel -SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION iiiii iiii BULB COLOR TEMPERATURE ORDINARY BLUE ORANGE/RED INTERMEDIATE YELLOW/GREEN HIGH EXTRA HIGH MAUVE ULTRA..HIGH BLACK NOV 2016 GFS-100b (Formerly A-65) //1 MAX. ORDERING INFORMATION STANPARDRESPONSE A UTOMA TIC SPRINKLERS CL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4 (5.7cm) White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) Wax Coated'.'4 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. 'HORIZONTAL SIDEWALL IS 29/16". 'WAX COATING cULus LISTED UP TO 200°F (93°C) ONLY. 'FINISHES AVAILABLE ON SPECIAL ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA 101-92-E - 135°F 155°F - 175°F 200°F **286F '1360°F (57°C) (68°C) (79°C) (93°C) (141°C) (182°C) GL2861 2.8 LH X X X X X X X X GL4261 4.2 LH X X X X X X X X UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X GL8161 8.0 ALL X X X X X X X X GL8164 8.0 ALL X X X X X X X X X X X GL2851 2.8 LH X X X X X X X X PENDENT GL4251 4.2 LH X X X X X X X X RECESSED GL5651 5.6 ALL X X X X X X X X X X X PENDENT GL8151 8.0 ALL X X X X X X X X X GL81 56 8.0 ALL X X X X X X X X X X X VERTICAL GL5675 5.6 LH X X X X X X X X SIDEWALLt GL8176 8.0 LH X X X X X X X HORIZONTAL GL2870 2.8 LH X X X X X X X X SIDEWALL GL4270 4.2 LH X X X X X X X X RECESSED GL5670 5.6 LH/OH X X X X X X X X X HORIZONTAL GL56710 5.6 LH/OH X X X X X X --- --- x x SIDEWALL GL8171 8.0 LH/OH X X X X X X X CONVENTIONAL GL5668 5.6 LH/OI-I X X X X X X --- --- X X (OLD STYLE) GL8169 8.0 LH/OH X X X X X X --- --- X X SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. 'BRASS FINISH ONLY WHEN RECESSED §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOWTHE CEILING, FM APPROVED 4" 106" BELOWTHE CEILING. ""NO FM APPROVALS FOR RECESSED DINSTALL IN ACCORDANCE TO 0S5306 AND ANY OTHER RELATED DOCUMENTS. "NO FM APPROVALS tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. OH: ORDINARY HAZARD tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. LH: LIGHT HAZARD 500°F (260°C) AVAILABLE UPON REQUEST WITH NO APPROVALS. ALL: ALL HAZARDS I h- 2 15/15" DI 2" DIA. MIS. X. _J I HOLE IN CEILING I I I 129/32' DIA.-./ I 1X 1/2" REDUCER Cl 1/8" MIN. - {7/8" MAX. CUP ETAINER' 1" 1IN, 1 3/4" MAX. SPECIFY Quantity. Model ° Number Style. Orifice Thread Size Temperature. Finish desired Quantity - Wrenches/Recessed Wrenches - P/N 325390/325391 (1/2"); P/N 312366/325401 (L.O.) Quantity Protective Caps - P/N 327109-CAP (Friction Fit Recessed) GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 L6"jr.~ 989-846-4583 FAX 989-846-9231 SIRE SPRINKLER CORPORATION 1-800-248-0278 www.gIobesprinkler.com NOV 2016 PRINTED U.S.A. GFS-100b (Formerly A-65) QUICK RESPONSE UPRIGHT CONVENTIONAL QUICK RESPONSE PENDENT VERTICAL SIDEWALL QUICK RESPONSE HORIZONTAL LPC/CE SIDEWALL HORIZONTAL SIDEWALL QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES FIRE SPRINKLER CORPORATION UPRIGHT S PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable stan- dards. It offers the additional feature of greatly increased safe- ty to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is ab- sorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distrib- uted in an approved pattern depending upon the deflector style used. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (570C), 155°F (680C), 175°F (790C), 200°F (930C), 286°F (141°C) Water Working Pressure Rating -175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Lodgement Wire - stainless steel • Bulb seat - copper Spring - nickel alloy • Seal - teflon Bulb - glass with alcohol based solution, 3mm size 'SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING NOV 2016 GFS-1 00a (Formerly A-20) Quick FESPONSE A UTOMA TIC SPRINKLERS GL SERIES UPRIGHT PENDENT VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (40 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) 4.2 (60 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Factory Bronze 5.6 (80 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Chrome White Polyester' 8.0 (115 metric) 1/2"NPT (15mm) 2 1/4" (5.7cm) Black Polyester23 8.0 (115 metric) 3/4"NPT (20mm) 27/16" (6.2cm) NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 2FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULus LISTED COROSION RESISTANT WHEN SPECIFIED ON ORDER. APPROVALS TEMPERATURE STYLE SIN MODEL K FACTOR HAZARD cULus FM LPC CE NYC-DOB MEA 101-92-E 135°F 155°F 175°F 200°F 286°F (57°C) (68°C) (79°C) (93°C) (141°C) GL2815 2.8 LH X X X X X X X GL4215 4.2 LH X X X X X X X UPRIGHT GL5615 5.6 LH/OH X X X X X X X X X X GL8115 8.0* LH/OH X X X X X X X GL8118 8.0 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X X GL4201 4.2 LH X X X X X X X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 8.0* LH/OH X X X X X X X X GL8106 8.0 LH/OH X X X X X X X X X X VERTICAL GL5632 5.6 LH X X X X X X X SIDEJALLt GL8133 8.0 LH X X X X X X --- GL2826 2.8 LH X X X X X X X HORIZONTAL GL4226 4.2 LH X X X X X X X SIDEWALL L GL5626 5.6 LH/OH X X X X X X X X GL5627o 5.6 LH/OH X X X X X --- --- X X GL8127 8.0 LH/OH X X X X X X CONVENTIONAL GL5624 5.6 LH/OH 7xx X X X X --- --- X X (OLD STYLE) GL8125 8.0 LH/OH X X X X --- --- X X 1bI`KINSLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA1 3 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4" TO 12" BELOW THE CEILING, FM APPROVED 4" TO 6" BELOW THE CEILING. aIN5TALL IN ACCORDANCE TO B55306 AND ANY OTHER RELATED DOCUMENTS. tPENDENT VERTICAL SIDEWALL cULus LISTED FOR 6' MIN. SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9' MIN. SPACING. OH: ORDINARY HAZARD LH: LIGHT HAZARD *1/2 NPT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • Model Number • Style • Orifice products found to be defective in material or workmanship for a Thread Size • Temperature Finishes desired period of one year from date of shipment. Quantity - Wrenches - P/N 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 . 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkIer.com FIRE SPRINKLER CORPORATION NOV 2016 PRINTED U.S.A. GFS-100a (Formerly A-20) FM Approved and Fully Listed Sprinkler Pipe Wheatland's Mega-Flow steel fire sprinkler pipe is FM Approved for roll-grooved, plain-end and welded joints for wet systems; and UL, C-UL and FM Listed for use with roll-grooved, plain- end couplings and welded joints for wet, dry preaction and deluge systems. Mega-Thread is FM Approved for use in wet systems and is UL, C-UL and FM Listed for wet, dry and preaction sprinkler systems. Approvals and Specifications Both products meet or exceed these standards: ASTM A795, Type E, Grade A NFPA 13 and NFPA 14 Mega-Thread is approved for standard hanger spacing Manufacturing Protocols Mega-Flow and Mega-Thread are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings Mega-Flow black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outlasts standard lacquer coatings. This coating allows the pipe to be easily painted without special preparation. Mega-Thread is hot-dip galvanized to meet FM requirements for dry systems and is safer to weld than many zinc-coated, light-wall threadable products. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. MEGA-FLOW SPECIFICATIONS NPS NOM OD NOM ID UL CRR* MEGA-FLOW Mega-Flow Schedule Schedule Schedule Mega-Flow Nominal Pcs./Luft 10 40 40 p4/ft 11/4 1.660 1.530 1.442 1.380 1.80 1.00 1.108 61 11/2 1.900 1.740 1,682 1.610 2.64 1.00 1.556 61 2 2.375 2.215 2.157 2.067 2.14 1.00 1.961 37 21/2 2.875 2.707 2.635 2.469 1.43 1.00 2.504 30 3 3.500 3.316 3.260 3.068 1.34 1.00 3.349 19 4 4.500 4.316 4.260 4.026 1.00 1.00 4.331 19 6 6.625 6.395 6.357 6.065 .75 1.00 8.000 10 'Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR Is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). MEGA-THREAD SPECIFICATIONS NIPS NOM OD NOM ID UL CRR* MEGA-THREAD Mega-Thread Schedule Mega-Thread Schedule L.W.T. Pipe Nil Pcs./Lift 1 1.315 1.087 1.049 1.00 1.00 .61 1.462 70 11/4 1.660 1.416 1.380 1.00 1.00 .39 1.989 51 1% 1.900 1.650 1.610 1.00 1.00 .31 2.370 44 2 2.375 2.117 2.067 1.00 1.00 .25 3.094 30 'Calculated using Standard UL CRR formula, (IL Fire Protection Directory, Category VIZY. The CRP Is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). (9) C& PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: MEGA-FLOW-BLACK MEGA-THREAD-HOT-DIP GALVANIZED Wheatland Tube IMC STEEL GPC'UP SCHEDULE 10 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm In. mm in. mm Ibs./ft. kg/rn CRR Lift 11/4 1.660 42.2 1.442 36.6 .109 2.77 1.81 2.69 7.3 61 1','2 1.900 48.3 1.682 42.7 .109 2.77 2.09 3.11 5.8 61 2 2,375 60.3 2.157 54.8 .109 2.77 2.64 3.93 4.7 37 21/2 2.875 73.0 2.635 66.9 .120 3.05 3.53 5.26 3.5 30 3 3.500 88.9 3.260 82.8 .120 3.05 4.34 6.46 2.6 19 4 4.500 114.3 4.260 108.2 .120 3.05 5.62 8.37 1.6 19 5 5.563 141.3 5.295 134.5 .134 3.40 7.78 11.58 1.5 13 6 6.626 168.3 6.357 161.5 .134 3.40 9.30 13.85 1.0 10 8 8.625 219.1 8.249 209.5 .188 4.78 16.96 25.26 2.1 7 'Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CR1? is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). SCHEDULE 40 SPECIFICATIONS NOMINAL NOMINAL NPS NOM OD NOM ID WALL WEIGHT UL PIECES In. mm in. mm in. mm Ibs./ft. kg/rn CRR Lift 1 1.315 33,4 1.049 26.6 .133 3.38 1.68 2.50 1.00 70 1¼ 1.660 42.2 1.380 35.1 .140 3.56 2.27 3.39 1.00 51 11/2 1.900 48.3 1.610 40.9 .145 3.68 2.72 4.05 1.00 44 2 2.375 60.3 2.067 52.5 .154 3.91 3.66 5.45 1.00 30 Calculated using Standard UL CRR formula, UL Fire Protection Directory, Category VIZY. The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe Is used as the benchmark (value of 1.0). @ C@ <.~PPROVED FM Approved and Fully Listed Sprinkler Pipe Wheatland's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL, C-UL and FM Listed. Approvals and Specifications Both products meet or exceed the following standards: ASTM A135, Type E, Grade A (Schedule 10) ASTM A795, Type E, Grade A (Schedule 40) NFPA13 Manufacturing Protocols Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. Finishes and Coatings All Wheatland black steel fire sprinkler pipe up to 6" receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black, or with hot-dip galvanizing, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. All Wheatland galvanized material is also UL Listed. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Barcoding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: LOCATIONS: COMMENTS: BLACK :i HOT-DIP GALVANIZED Wheatland Tube JMC STEEL GROUP Fire Products Division of Anvil International January 2010 For the most current product/pricing information on Anvil products, pleas visit our website at www.anvilintl.con BUILDING CONNECTIONS THAT LAST çgw (z)'!J CMJIL 4vt ( LMuzJ For over 150 years, Anvil has worked diligently to build a strong, vibrant tradition of making connections - from pipe to pipe and people to people. We pride ourselves in providing the finest-quality pipe products and services with integrity and dedication to superior customer service at all levels. We provide expertise and product solutions for a wide range of applications, From plumbing, mechanical, HVAC, industrial and fire protection to mining, oil and gas. Our comprehensive line of products includes: grooved pipe couplings, grooved and plain-end fittings, valves, cast and malleable iron fittings, forged steel fittings, steel pipe nipples and couplings, pipe hangers and supports, channel and strut fittings, mining and oil field Fittings, along with much more. As an additional benefit to our customers, Anvil offers a complete and comprehensive Design Services Analysis for mechanical equipment rooms, to help you determine the most effective and cost-efficient piping solutions for your pipe system. At Anvil, we believe that responsive and accessible customer support is what makes the difference between simply delivering products - and delivering solutions. MERIT Weld-Miser TM Tee-Let® Welding Outlet Fittings Unified DesignTM Series Merit's Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings. Merit® Weld-Miser Tee-Let0l are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets on thin wall or proprietary flow pipe. Typically only one weld-pass completes the Installation. Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications. To accomplish this: The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or main thereby Insuring complete penetration without cold welds, weld roil-off, burn-through or excessive distortion. - - -I- - - On smaller sizes a heavier section is maintained on the threaded end of the fitting. This protects the threads from dam- age during shipping and handling prior to Installation as well as from weld distortion. Each outlet size 11/2" and larger, whether male or female threaded, cut grooved or beveled requires the same hole size In the header pipe. This simplifies the installation process. General Specifications Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53, Grades A or B, Type E. Ease of installation is assured when automatic welding equipment is used to Install Merit Tee-Lets. Threads are cut in accordance with the requirements of ANSI B1.20.1, national standard for tapered pipe threads, or ISO-7-1 threads are available. Tee-Let threaded and grooved welding outlet fittings are IJLIULC Listed and FM Approved for use in the fire sprinkler systems Installed in accordance with the requirements of NFPA Bulletin 13. They are rated for 300 PSI operation in fire sprinkler systems, and higher pressures In other non-critical piping systems. Tee-Lets are offered in a wide variety of header sizes. The consolidated header sizes shown in the following charts allow the fittings to be Installed on more than one header size, permitting the first size listed to fit the header perfectly, while a small gap along the longitudinal center line of the header will appear for the second size listed. Merit® WeldMiserTM Tee-Lets® are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify WeldMiserTM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel, employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10, proprietary thin wall, and standard wall pipe. Threads are to be ANSI B1.20.1, or ISO-7-1, and the bore of the fittings calculated to improve flow. Welding outlets to be UL Listed, FM Approved for use conforming to NFPA, Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit® WeldMiserTM Tee-Let®. Method No. 1 Method No. 2 Specify quantity desired followed by the part Use the following system: number shown in the "dimensions" chart for the type and size of outlet desired. - Type Merit Steel Quantity Part Number Quantity $ Outlet Size * Header Size $ Weight End Tee-Let Material 44 Always Column "A" Insert size Sch. 10 A - Female Thread order a few of Chart consolidation Standard B - Male Thread more than from Column C - Cut Groove actually "B' of chart. C/R - Roll Groove required for the lob. INVtL.Btar Merit -1.10 —3— Rre ft&cft DlvIUot, ofAM karriWorW IVT Weld-Miser TM Tee-Let® Welding Outlet Fittings LN VED dr.h widad ,p,os.nlalNo For Fire Protection & Other Low Pressure Piping Systems Merit Weld-Miser Tee-Lets Welding Branch Outlet Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and manufactured to be Installed on Schedules 5 thru 10, proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings. The material used In manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B, Type E, A-135, A-795, Tee-Lets employ a low weld volume design to provide for either a partial or full penetration weld employing a single pass with minimum bum-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall, Schedules 5, 10 and 40 pipe. Threads comply with ANSI B1,20.1 or lSO7/1. They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 13 1999 of the National Fire Protection Association. When used in fire sprinkler systems, Tee-Lets are rated for 300 psi. When used in mechanical systems, maximum pressures are calculated using criteria developed for ASME B31 piping code. TEE-LET WELDED OUTLET Outlet Model FITTING (LIL VIZU — EX6032, Outlet Pipe Size (Inch) FM APPROVAL GUIDE CHAPTER Header Pipe Size (Inch) 1 PIPE FITTINGS) Rated Pressure (psig) Tee-Let Type A (F-Threaded End) ½,3/4,1 11/4. 114, 2, 2½, 3,4 14-8(Sch.10,40) 300 6 (EZ-Flow) ½. 4 (Sch. 5, DynaFlow) 2 4 (EZ-Flow) - 2,4 Tee-Let Type C (Grooved End) 1¼. 8 1¼. 8 (Sch. 10, 40) 300 2½-B 144 (Sch. 5, DynaFlow) Tee-Let Type CIR (Roll _Grooved _End) 11/4-6 1¼. 8 (All Schedules) 300 Size-on-size (i.e. 2 x 2) Tee-Lets are not FM Approved. FM rated working pressure when welded on Sch. 5 or non-threadable lightwall pipe is 175 psi. —4— Merit-1.10 lb. Pr.ductg Ovfdan afAlllrnemadonal Type A Female Threa WELD -MISER T1 TEE-LET141 DIMENSIONS Part Nominal Nominal Outlet inside Make Weight Number Outlet Header Length Diameter Up Each A B C 0 M NPT(8SPT) In (mm) In (mm) In (mm) In (mm) In(nsn) Lb. (kg) 1002002 ¼x 114-8 - 0.080 0' 6 200 - 0.04 1005012 11/4 -114 1.063 0.700 0.500 0.171 32 40 270 178 12/ 0.08 1005015 114-2 1.063 0.700 0.500 0.171 ________ ½x .10 50 27.0 /7.8 121 0.08 1005020 2-2½ 1.063 0.700 0.500 0.171 50 65 270 11.8 127 0.08 1005025 214-8 1.063 0.700 0.500 0.169 65 20/) 27.0 178 12.1 008 1007012 11/4 -114 1.125 0.900 0.500 0.260 .12 -iLl 28.6 229 121 012 1007015 1½-2 1.125 0.900 0,500 0.260 3/4 x 40 50 28.6 229 12.7 0.12 1007020 ' 2- 21A 1.125 0.900 0.500 0.260 50 65 . 28.6 229 /2.1 0.12 1007025 214-8 1.125 0.900 0.500 0.256 6; 200 . - 28.6 229 121 012 1010012 1¼-1½ 1.250 1.145 0.500 0.331 1/00012 .12-40 31.8 21.1 12..' 0.15 1010015 114-2 1.250 1.145 0.500 0.331 1110015 4050 31.8 29/ 12.1 0.15 1010020 2-2½ 1.250 1.145 0.500 0.320 1110020 lx - ;U65 318 29.1 12.1 0.15 1010025 214-3 1.250 1.145 0.500 0.314 7110025 6580 31.8 29.1 1 121 0.14 1010030 3.4 1.250 1.145 1 0.500 0.309 1/10030 80 - 100 3113 29.1 12.1 0.14 1010050 5-8 1.250 1.145 0.500 0.291 1110050 125-200 1 318 29/ /2.7 013 1012012 11/4 1.375 1.490 0.500 0.432 1112012 32 34.9 31.8 12.1 .0/9 1012015 114-2 1.375 1.490 0.500 0.421 /1121)15 .1(150 34.9 31.8 72.7 .018 1012020 2-2½ 1.375 1.490 0.500 0.421 1112020 11/4 X '.- 50 '55 34.9 37.8 127 .019 1012025 2½-3 1.375 1.490 0,500 0.411 1!1202s 6.560 34.9 37.8 12.7 .019 1012030 3-4 1.375 1.490 0.500 0.389 17/20.10 80'100 34.9 378 /2.1 1018 1012050 5-8 1.375 1.490 0.500 0.389 7112050 /2.5200 a-i.c 31.3 /2.7 .0/LI 1015015 114 1.625 1.610 0.875 0.477 /115375 40 41.1 )0I9 2~12 .022 1015020 2 1.625 1.610 0.875 0.477 111;020 1½x 50 41.3 -p0.0 I 22. 022 1015025 214 1.625 1.61,0 0.875 0.477 111a015 . ' 0 4)3 -0)9 21] .022 1015030 3-4 1.625 1.610 0.875 0.477 /171030 80 /1)0 4/3 40.9 22) 1015040 4 1.625 1.610 0.875 0.477 /115040 IOU 4.3 4 4_2 1015050 5-8 1.625 1.610 0.875 0.477 &ME 4AlT. Weld-Miser TM Tee-Let® Welding Outlet Fittings WELD-MISER" DIMENSIONS RS Nominal Nominal IPARTNUMBE Part Outlet Inside Make Weight b Number Outlet Header Length Diameter Up Each h A B 0 NP7'3SPT In (nun) In (mm) In (mm) In (mm) In (mm) Lb.() 1020020 2 1.750 2.067 0.875 0.857 1120020 50 44.5 .52.5 22.2 i/33 1020025 214 1.750 2.067 0.875 0.829 1120025 65 44.5 52.5 222 038 1020030 3 1.750 2.067 0.875 0.829 11211030 2x 80 445 525 222 I/J9 1020040 4 1.750 2.067 0.875 0.800 /120040 7(6) 44; 52.5 222 03/) 1020050 5 1.750 2.067 0.875 0.743 1120050 125 44.5 52.s 22.1 034 1020060 6 1.750 2.067 0.875 0.743 1120060 150 4.15 52.5 222 0J4 1020080 8 1.750 2.067 0.875 0.743 11200511 1 280 1 44; 52.5 222 1 0,j4 1025025 21/t 2.215 2.469 1.125 1.250 112502; 65 54.0 52.7 28.6 05s 1025030 3 2.215 2.469 1.125 1.200 1125030 00 540 62.7 28.6 0.5; 1025040 4 2.215 2.469 1.125 1.150 /125040 2½x 1 100 310 627 28.6 0.52 1025050 5 2.215 2.469 1.125 1.150 1125850 125 54.8 62.7 28.6 0.52 1025060 '6 2.215 2.469 1.125 1.150 1125060 150 540 62.7 28.6 0.52 1025080 8 2.215 2.469 1.125 1.150 /125080 2011 540 62.7 28.6 1 052 1030030 3 2.500 3.068 1.500 1.550 - 80 63.5 /1.9 38.1 0.10 1030040 4 2.500 3.068 1.500 1.450 - 3 x 180 611.5 2.500 ' 11.9 381 056 1030050 5 3.068 1.500 1.450 125 83.5 71.9 38.1 0.66 1030060 6 2.500 3.068 1.500 1.450 15(1 63.s 17.9 30.1 0.66 1030080 8 2.500 3.068 1.500 1.450 "CO 63.5 12.9 381 0.66 1040040 4 3.000 4.026 2.000 2.850 110 76.2 103.3 500 7.29 1040050 5 3.000 4.026 2.000 2.850 4 x 12 76.2 10173 50.8 /29 1040060 6 3.000 4.026 2.000 2.800 _________ '.5) 2 /02,2 5/iS /27 1040080 8 3.000 4.026 2.000 2.800 7..' 152 , 2 bb 12 Note: Part #1002002 is not UL Listed or FM Approved. Part #1012012 is not FM Approved. All size-on-size (i.e 2 X 2) Tee-Lets are not FM Approved ANVkStar- Ment- 110 -5- Rs* PmductsDMdan ArvfJ fl!m1don& Weld-Miser TM Tee-Let® Welding Outlet Fittings Type B Male Thread Standard Weight Type C Cut Groove Standard Weight RT WELD-MISE P" V! DIMENSIONS usianrii iuuw Male Thread Cut Groove Nominal Outlet Nominal Header Outlet Length Inside Diameter Outside Diameter Wail Thickness Sid WI Std. Wt. A B C 0 E F NPT(3SPT) NPT(6SPT) In.frnn) ln.(isi) ln4rnm) In4nmn) In.friiii) ln.(mra) 1310012 2010012 11/4 1½ 3 1.049 1.315 0.133 32 49 80 118 8 334 34 1310015 2010015 114-2 3 1.049 1.315 0.133 lx 40 50 80 26 b 3i.4 3.4 1310020 2010020 2-214 3 1.049 1.315 0.133 SI) 6 80 'G,b 33.4 3.1 1310025 2010025 2½-4 3 1.049 1.315 0.133 65 - 1011 80 26.6 334 34 1310050 2010050 5-8 3 1.049 1.315 0.133 125 1,100 80 266 33.4 3.1 1312012 2012012 11/4 3 1.368 1.660 0.140 32 80 34.1 422 3.6 1312015 2012015 114 3 1.368 1.660 0.140 lt/4x 40 80 34.1 422 36 1312020 2012020 2-2½ 3 1.368 1.660 0.140 59 65 80 3141 42.2 3 b 1312025 2012025 3-4 3 1.368 1.660 0.140 80 lOu 89 34 / 42.2 36 1312050 2012050 5-8 3 1.368 1.660 0.140 125 200 80 34 7 422 3.6 1315015 2015015 114 3 1.610 1.900 0.145 40 801 -10.9 48.3 .3.1 1315020 2015020 2 3 1.610 1.900 0.145 1½x 50 80 109 483 3.7 1315025 2015025 214 3 1.610 1.900 0.145 65 80 40.9 48.3 3.1 1315030 2015030 3.4 3 1.610 1.900 0.145 80- IOJ 80 40.9 .18.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 125 -200 80 40.9 48.3 31 1320020 2020020 2 3 2.067 2.375 0.154 80 525 80.3 39 1320025 2020025 214 3 2.067 2.375 0.154 65 80 525 60.3 3.9 1320030 2020030 3 3 2.067 2.375 0.154 2x 80 80 5075 603 3.9 1320035 2020035 4 3 2.067 2.375 0.154 (Oil 110 52.5 63 .3.9 1320050 2020050 5 3 2.067 2.375 0.154 125 80 52.5 69.3 35 1320060 2020060 6 3 2.067 2.375 0.154 150 80 62.5 673 39 1320080 2020080 8 3 2.067 2.375 0.154 253 70 525 c13.3 33 Note: Tee-Lets are manufactured to fit size-on-size, that is the contoured shane on a olven Tee-I et is made to fit nerferithi on the first listed header size If Installed on the second header size marked on the fitting, a slight gap of approximately ikE will appear along the longitudinal centerline of the header. For example, a 1' x 2 - 214' Tee-Let, is a 1' outlet fitting manufactured to fit perfectly on the 2' header size listed, while leaving a ½2' gap along the longitudinal centerline of the 21/V size. If a perfect fit Is required for a 214' header pipe, then a 1"x 214 - X Tee-Let would be ordered. Size consolidations are employed to reduce Inventory and provide for greater flexibility. -6- Merit- 1.10 The Products OMXofAnvI1Internadii -- Type B Male Thread Standard Weight Type C Cut Groove Standard Weight Type C/R Roll Groove Schedule 10 WeIdMiserTM Tee-Let® Welding Outlet Fittings WELD-MISER Tm TE DIMENSIONS (NOMI NAL SIZES ptVAiJI!Til1 j Male Thread ad Cut Nominal Nominal Outlet Inside Diameter 0 Outside Wall Thickness F Standard Schedule Standard Schedule Groove Ski. Outlet Header Length Diameter WI. A B C Weight 10 E Weight 10 NPT (150 7.1) Nfl (ISO'?!) NPT(ISOJ-1) ln.(rnm) In.(mm) k(mm) ft(mm) In.(mm) ln.(mm) ft(mm) ft(mm) 1325025 2025025 2225025 21h 3 2.469 2.635 2.875 0.203 0.120 6 80 621 51.0 1 16.2 50 3.0 1325030 2025030 2225030 3 3 2.469 2.635 1 2.875 0.203 0.120 2125031) 80 80 62.7 670 76.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125085 2½x OJO 80 52.7 67.11 76.2 50 3.0 1325050 2025050 2225050 ' 5 3 2.469 2.635 2.875 0.203 0.120 2175050 125 80 1 62.7 67.0 76.2 1 50 3.0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 151) 80 627 81.0 16.2 50 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 2011 80 621 6121 782 50 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 80 18.0 83.0 88.0 50 3.0 1330035 2030035 2230035 314 3 3.068 3.260 3.500 0.216 0.120 85 80 780 83.0 88.0 5.0 JO 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120- 3 x 4. 100 80 /8.0 83.0 88.0 JO 3.0 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 125 80 18.0 83.0 88.0 1 5.0 3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 150 811 78.0 83.0 88.0 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 80 (8.0 83.0 85.0 5.0 3.0 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 190 1110 102.0 103.0 1 11.40 5.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4 x 125 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 6 4 4.026 4.260 4.500 0.237 0.120 Fhb /00 112.0 195.0 114.0 6.0 30 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 1 lOLl 102.6 103.0 114.6 6.0 30 - 2050050 - 5 4 5.047 - - 5x 125 100 125.? - 2050060 - 6 4 5.047 - - 153 1011 1262 - 2050080 - 8 4 5.047 - - 201' 126.2 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6x ' ,.53 Ilk; 1550 Jo') 1158,4 3.0 - 2060080 2260080 8 4 6.065 6.357 6.625 0.280 0.134 155. ;c:. 760IL;. - 2080080 - 8x 8 4 7.981 8.329 8.625 0.322 0.148 $) .36 Note: Tee-Lets are manufactured to fit size-on-size. that is the contoured shane on a niven The-Let Ic maite to fit nerfeilth, on the lirct Iited herIer d,e If inctIId on the second header size marked on the fitting, a slight gap of approximately 142' will appear along the longitudinal centerline of the header. For example, a r x2 21/T Tee-Let, Is a 1' outlet fitting manufactured to fit perfectly on the 2' header size listed, while leaving a ½2' gap along the longitudinal centerline of the 214' size. If a perfect fit is required for a 21/t' header pipe, then a 1' x 2½- 3' Tee-Let would be ordered. Size consolidations are employed to reduce inventory and provide for greater flexibility. Y&AVLBtar- Merit-I 10 -7 - Fire Pludvcft,ion oMI hrtemreiøeai July 2012 For the most current product/pricin information on Anvil products, plea. sit our website at www.anvilintl.co 4 Ir'1rERN,TIar1AL '-.... ..- Building Connections That Last I]IJt 'i;i1t !llfIi fl [fl [I 1TI BUILDING CONNECTIONS THAT LAST cuvxi Catawissa AThRLEPS 1J1L 4 ((Ii im-iiJ S! &l Dimensional: ASTM A733 Material: I ASTM A53 Type F or Type E Galvanizing: I Hot Dip Galvanizing* Threading:** I ASME B 1.20.1 Standard End Finish Tapered Pipe Thread (NPT) Standud Welded Anvil International is the only manufacturer where you can combine your import and U.S. Manufactured I product requirements. *Galvanized nipples are manufactured from pipe coated on the inside and outside by hot dip process. **British Standard threading per BS 21 available upon request. Ends are cut square to the central axis. All burrs on Also available: the inside are removed. The ends of the pipe nipples Ready Cut Pipe, Standard - Schd. 40 (black and galvanized) are chamfered on the outside at an angle of 35' +1- Pipe Size: '/2',/4, 1", 11/4, 1/2, 2" 10 to the central axis. Pipe Length: 8', 24", 30", 48', 60", 72" "66" Packs, Standard - Schd. 40 (black and galvanized) Pipe nipples are threaded on both ends with Nipple Size: /2,/4, 1", 11/4 , 1'/2, 2" standard NPT tapered threads. Threads are right • Single Run Nipple Packs (black and galvanized) hand on both ends. Pipe Size: 1/7, 3/4", 1, 1/4, 11/2, 2" Pipe Size 1/8 Pipe .405 .!1if 3/4 '1 1/2' 2 '2'/2' 3 rnTiNipple '31/2' Lengths 1:] 4 '4'/2' 5 iIgalvanized) '5'/2' 6 ' 7 8 ' 9 'lO'll 12 1/4 .540 /8 1 1/2 2 2 72 3 3 '/2 4 41/2 5 5 '/2 6 7 8 9 10 11 12 3/8 .675 1 1'/2 2 2 /2 3 31/2 4 4'/2 5 51/2 6 7 8 9 10 11 12 .840 1 1/8 1 1/2 2 21/2 3 3'/2 4 4 '/2 5 5 '/2 6 7 8 9 10 11 12 3/4 1.050 1 3/ 1 1/2 2 2 '/2 3 3'/2 4 4 '/2 5 5 1 /2 6 7 8 9 10 11 12 1 1.315 1'/2 2 2'/2 3 3'/2 4 4'/2 5 5'/2 6 7 8 9 10 11 12 1 1/4 1.660 1 5/ 2 21/2 3 372 4 41/2 5 5 '/2 6 7 8 9 10 11 12 1 1/2 1.900 1 3/4 2 21/2 3 31/2 4 41/2 5 51/2 6 7 8 9 10 11 12 2 2.375 2 2'/2 3 3'/2 4 41/2 5 51/2 6 7 8 9 10 11 12 2 1/2 2.875 2 1 /2 3 1 3 '/2 4 4 '/2 5 5'/2 , 6 7 8 9 10 11 12 3 3.500 2/8 3 3'/2 4 41/2 5 51/2 6 7 8 9 10 11 12 4 4.500 2/a 4 41/2 5 51/2 6 7 8 9 10 11 12 6 6.625 31/s 12 AIVIIL Ix rj • . . SPF-3.1 EI 1II G5EIT1 Class ll© (Standard) ir / ( 1:1111 1-I -- • Size A Weight - MEN FA- *1' • kx'i1 Class II 50 (ndd) CAP / ' 1 IA ½A 0.53 0.03 1/4 A 0.63 0.05 0.74 0.07 1/2 0.87 0.11 1 ½ 1.28 0.44 1 1/2 1.33 0.55 2 1.45 0.85 2 1/2 1.70 1.49 3 1.80 2.20 3'/2 1.90 3.02 4 2.08 3.79 6 2.55 8.77 A Supplied in Steel only (Black and Galvanized). TEE 'Alk '/8 0.69 0.09 1/4 0.81 0.14 0.95 0.21 3/ ½ 1.12 0.31 '14 1.31 0.50 1 1.50 0.79 1 1/4 1.75 1.19 1 ½ 1.94 1.57 2 2.25 2.43 2 1/2 2.70 4.33 3 3.08 6.37 4 3.79 11.03 6 5.13 25.98 *11 El g ILI 1:"rG;l j4w 16 1 MTT IM Class II (andard) REDUCING COUPLINGS - '/4x 1/8 1.00 0.07 3/sx½ 1.13 0.09 3/8 x¼ 1.13 0.10 '½x½ 1.25 0.13 '/2x'/4 1.25 0.13 V2 X 1.25 0.14 3/4 x 1/8 1.44 0.18 3/4 x'/4 1.44 0.20 3/4 x 3/8 1.44 0.21 3/4 X½ 1.44 0.22 1 x½ 1,69 0.34 1x 3/4 .69 0.36 1 '/4x'/2 2.06 0.47 1 ¼x% 2.06 0.51 1 1/4 x 1 2.06 0.57 1 '/2x½ 2.31 0.62 1 '/2x 3/4 2.31 0.66 1½x1 2.31 0.73 1 Y2x1 ½ 2.31 0.80 2x½ 2.81 0.94 2x 3/4 2.81 0.99 2 x 1 2.81 1.03 2 x 1 '/, 2.81 1.17 2x1½ 2.81 1.25 2'/2x1 1/4 3.25 1.81 2'/2x1 ½ 3.25 1.90 2'/2x2 3.25 2.04 3 x 1 3.69 2.48 3 x 1 ½ 3.69 2.55 3 x 1 '/2 3.69 2.67 3 x 2 3.69 2.78 3 x 2 ½ 3.69 3.23 4 x 2 4.38 4.43 4x2½ 4.38 4.87 4 x 3 4.38 5.29 PLUGS I Weight i :E 14 Cored Solid 1/4 0.44 0.28 0.38 0.04 Solid /s 0.48 0.31 0.44 0.06 Cored ½ 0.56 0.38 0.56 0.08 Cored 3/4 0.63 0.44 0.63 0.13 Cored 1 0.75 0.50 0.81 0.20 Cored 1 ½ 0.80 0.56 0.94 0.32 Cored 1 ½ 0.83 0.62 1.13 0.43 Cored 2 0.88 0.68 1.31 0.67 Cored 2½ 1.07 0.74 1.50 1.11 3 1.13 0.80 1.69 1.53 Bar Plug 4 1.22 1.00 - 2.71 Bar Plug 6 1.40 ---F-1.25 I - 4.00 iivo :I SPF-3.1 NVI The C-3 Coupling is a flexible light weight style which is ideal for fire protection services and other services where low pressure and ambient temperature conditions are expected. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c®us <~> OLPM USTED APPROVED For Listings/Approval Details and Limitations, visit our website at w,wv.anailintl.com or contact an Anvil- Sates Representative. MATERIAL 1 J ['1 I. HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-i 83 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) El Hot Dipped Zinc Galvanized (optional) El Other available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: []Standard Gruvlok []Gruvlok XtremeTM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. Pre-Lubricated Grade "E" EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. 0 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. Grade "EP' EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: O Standard C Style Flush Gap PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: []Approved as noted Contractor: J Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 NVIL .cILIGHTWEIGHT FLEXI BLE COUPLING Nominal Pipe Max. End Range of Deflection From Q Coupling Dimensions Coupling Bolts Specified Torque § Size 0. D. Working PressureA Load Approx. Wt. En. Per Coupling Pipe X Pipe End Separation V Z Qty. Size Mm. Max. In./D9(mm) In/mm PSI/bar Lbs./kN in/mm Degrees In/Ft. . mm/at In./mm In./mm In/mm in/mm Ft-Lbs/N-rn Lbs/Kg 1 1.315 300 407 0.1/32 10 22' 0.29 21/2 4 1/4 2 x 2V4 30 45 1.2 25 334 20.7 1.81 0-0.79 1 23.8 64 1 102 44 M10x57 1 40 60 1 0.5 11/4 1.660 300 649 0.1/32 10 5 0.23 21/4 41/4 13/4 2 /t x 21/4 30 45 1.3 32 42.2 20.7 2.89 0019 /8.8 70 III 44 Vox 50 40 60 0.6 1½ 1.900 300 851 0.1/32 00 51' 0.20 3 41/2 13/4 2 3/tx21/4 30 45 1.5 40 48.3 20.7 3.78 0-0.19 165 76 1/7 44 M!0 50 40 60 0.7 2 2.375 300 1,329 0-1/3 00 45 0.16 3% 5 11/8 2 3/8 x2'/4 30 45 1.7 50 60.3 20.1 591 0079 /3.1 o6 /40 48 M10, 57 40 30 0.8 21/2 2.875 300 1,948 0-Y32 00 37' 0.13 31/8 51/2 11/8 2 3/ x 21/4 30 45 2.0 65 73.1) 207 0.66 0M.79 /0.9 99 146 48 - 41/0x57 40 60 0.0 30.0. 2996 300 2,1 /5 0- 036 013 4 57 II 2 x2' 30 45 19 76.1 76.1 20.7 9.41 0-0.79 10.4 105 146 48 - M10 x 57 40 60 0.9 3 3.500 300 2,886 0./32 00 31 0.11 41/2 61/8 11/8 2 1/2 x 2/2 30 45 2.6 86 81)9 20.1 /2.34 0-0/9 8.9 /14 1 /56 48 1 MIOx 63 1 40 60 1 1.2 4 4.500 300 4,771 0-3/xl 10 12' 0.67 6¼ 8 2% 2 /8 x 3½ 80 100 4.1 /00 H4.3 20.7 2/22 0-2,38 ______ 55.5 156 203 5/ - M12x 70 110 /50 1.0 5V0.0. 5.500 300 7/27 0.1 . 0.590 0.54 60 9W 2- 2 'x3½ 100 /30 55 139.7 139.7 1 20.7 31.70 0-2.38 45.4 175 237 57 - M16 x 89 135 175 2.5 5 5.563 300 7,292 0-/32 00 58' 0.54 7 9Y16 2% 2 5/a x 31/4 100 130 5.7 125 141.3 207 32.44 0-6.4 45 178 1 231 51 1 - 41/6,485 /35 1/5 26 6,000 o500 300 9,955 04. 0450 04o 7 /01, 04 2 ',.3. /00 /30 6/ 165.1 165.1 20.7 44.28 0-2.38 1 34.8 200 267 57 - M16 x 85 135 175 2.8 6 6.625 300 10,341 0-/32 00 49 0.45 81/4 103/4 21/4 2 x 31/4 100 130 6.1 1SO /88.3 20.1 46.09 0-2.38 318 210 2/3 57 4116x85 135 175 2.8 8 8.625 300 17,528 0-/32 00 37 0.35 101/8 131/2 21/2 2 3/4 x 41/4 130 180 11.9 200 2/9.1 107 7797 02.38 29/ 270 1 343 1 64 1 - /420x110 175 245 . 5.4 Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. One time field test pressure may be increased to 1.5 times the figures listed above. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. FP-4.12 I WARNINGJ For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok! XtremeTM Lubricant is required. NVI The C-4 Rigid Coupling is our standard coupling and is designed for rigid piping applications. The C-4 is specially designed to provide a rigid, locked-in pipe connection to meet the specific demands of rigid design steel pipe. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. c®us LPW LTED APPROVED 0 For Listings/Approval Details and Limitations, visit our website at wa.anviIintl.com or contact an Anvil° Sales Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to ASTM A-i 83 Grade 2 with a minimum tensile strength of 110,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A or Grade B, or SAE J995 Grade 2. Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: 0 Rust inhibiting paint Color: ORANGE (standard) DHot Dipped Zinc Galvanized (optional) l:lother available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: OStandard Gruvlok Gruvlok XtremeTM required for dry pipe systems and freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. o Pre-Lubricated Grade "E' EPDM, Type A Gasket (Violet color code) -40°F to 150°F (Service Temperature Range)(-40°C to 65°C) Recommended for wet and dry (oil free air) pipe fire protection sprinkler systems. For dry pipe systems and freezer applications, Gruvlok XtremeTM Lubricant is required. 0 Grade "E" EPDM (Green color code) -40'F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. 0 Grade "EP" EPDM (Green and Red color code) -40°F to 250°F (Service Temperature Range)(-40°C to 121°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many other chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. GASKET TYPE: O Standard C Style E] Flush Gap PROJECT INFORMATION APPROVAL STAMP Project: III Approved Address: [-]Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 Rigid Coupling ANVIL liii IIII iI•L I11P1 11111 C-4 IRIGIDICOUPLING Nominal Pipe Max. Max. Coupling Dimensions Range of Pipe Coupling Bolts Specified Torque § Approx. Size O.D. Working pressureA En Ion En Separation X V Z Wt. En. Qty. Size Min. Max. InjDN(mm) In/mm PSI/bar Lbs./kW mInim In /mm In 1mm In1mm In ./= Ft-Lbs/N-rn Lbs 1Kg 1 1.315 300 401 0-132 2% 4 ]3/4 2 %x21/4 30 45 1.2 25 33.4 20.7 98/ 0-0.79 60 /02 44 M10x57 40 60 0.5 1/4 1.660 300 649 0.1/32 21/4 4118 11/8 2 % x 21/4 30 45 1.5 32 42.2 20.7 289 0-0.79 70 /17 48 M10x57 40 60 0.7 11/2 1.900 300 851 0-/ 2'/i 41/8 17/ 2 % x 21/4 30 45 1.7 40 1 48.3 20,7 3.78 0-0.19 71 124 48 A110': 51 40 60 88 2 2.375 300 1,329 0.1/32 31/3 5% 2 2 % x 21/4 30 45 1.9 50 60.3 207 391 1 0-0.79 89 /37 3/ #110x 57 40 60 0.9 21/2 2.875 300 1,948 0.1/32 4 6 2 2 % x 21/2 30 45 1.9 65 73.0 20.7 8.66 0-0.79 102 /52 51 - 1,110 x 63 40 60 0.9 30/1 2996 300 Z 11 0-". 4.. 6" / 2 '2" 30 45 2.2 76.1 1 76.1 20.7 9.41 0-0.79 105 156 48 - M10 x 63 40 60 1.0 3 3.500 300 2,886 0.1/32 41/4 61/s 2 2 % x 21/2 30 45 2.4 80 88.9 20.7 /2.84 1 00.79 /21 /68 5/ M/0 63 40 60 4 4.500 300 4,771 0-/32 5/8 73/4 21/8 T %x2½ 30 45 3.2 /00 114.3 20.7 21.22 0-2.38 149 197 54 - M!0 63 40 60 1.4 5500 300 7,127 01'. 6' 91 2. 2 -3 80 /0/1 139.7 139.7 20.7 31.70 0-2.38 175 235 1 52 - M12 x 76 110 150 1 2.2 5 5.563 300 7,292 0-/32 61716 91/j 21A6 2 1/2 x 3 80 100 4.5 125 141.3 20.7 32.44 1 0-2.38 /76 230 57 - 6112116 NO /30 2.0 - 6 09 6500 300 9955 0-" 5. /9:- 2. 2 : A 8 80 100 5.8 165.1 165.1 20.7 44.28 0-2.38 207 264 54 - M12 x 76 110 150 2.6 6 6.625 300 10,341 0-/32 81/4 10% 21/i 2 1/2 x 31/4 80 100 5.8 /30 /68.3 20.7 46.00 0-2.38 2/0 264 54 - 112x82 110 /50 2.6 8 8.625 300 17,528 Q3/33 101/2 131/4 21/2 2 1/8 x 31/2 100 130 10.8 200 2)91' 20.7 77.97 1 0-2.38 267 537 64 M it, 89 130 /75 49 10 10.750 300 27,229 0-/32 13 16~ 2% 2 1/sx5 180 220 21.5 250 2731 20.7 /2/12 0-2,38 35'! 423 67 1222 .v/25 245 293 98 12 12.750 300 38,303 0-/32 15% 19% 21/8 2 '/ x 5% 180 220 27.4 300 323.9 20.7 170.38 0-2.38 39/ 489 61 - M221 /40 245 298 /2.4 Range of Pipe End Seperation values are for roll grooved pipe and may be doubled for cut groove pipe. Working pressure and/or end load are total allowable, based on standard weight steel pipe, roll or cut grooved. WARNING One time field test pressure may be increased to 1.5 times the figures listed above, For dry pipe systems and freezer applications § - For additional Bolt Torque information see Technical Data Section. lubrication of the gasket is required, ,LI.,.,,,, i,,,,- Gruvlok® XtremeTM Lubricant is required.-------------------------------_.1L__J__..L ..... . ,, ,..,, .,.... ..,., J9Jc. , u, ,,,cIu,c,,JIq,J,.,_, I ,v, vu., u,,u L1O pievvuie ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Other sizes available, contact on Anvil Representative. FP-4.12 NZY <e> com) LISTED APPROVED For Listings/Approval Details and Limitations, visit our websita at wew.anvitintl.carn or contact an Anvil5 Sales Representative. MATERIAL SPECIFICATIOPJS CAST FITTINGS: Ductile Iron conforming to ASTM A-536 FINISH: ERust inhibiting paint Color: ORANGE (standard) or []Hot Dipped Zinc Galvanized conforming to ASIM A-] 53 (optional) 0 Other available options: Example: RAL3000 or RAL9000 Series 900 Elbow :SP~F~/RNVIL -T O.D. -i U to E Nominal 0 D Max. (enter Approx. Size to End Pr sSUTe Wt. Ea. InjDNmm) In1mm PSI/bar In 1mm Lbs/Kg 1 1.315 300 21/4 0.6 25 33.4 20.7 51 03 1¼ 1.660 300 21/4 0.8 32 42.2 20.7 10 0.4 11/2 1.900 300 21/4 1.1 40 48.3 2017 70 0.5 2 2.375 300 31/4 1.5 50 60.3 20.7 83 07 21/2 2.875 300 33/4 2.5 65 73.0 20.1 95 1 30.0 2.996 $00 3 29 76.1 76.1 20.7 95 1.3 3 3.500 300 41/4 4.2 Be 889 201 /08 19 4 4.500 300 5 6.7 /00 /14.3 20.7 /27 3.0 51A 0.0. 5.500 300 5½ - 139.7 139.7 20.7 140 - 5 5.563 300 51/2 11.9 125 141.3 20/ 140 1 5.4 6/00. 6.500 300 6 18.2 165.1 165.1 20.7 165 8.3 6 6.625 300 61/2 17.3 /50 1 /68.3 20/ 1 /65 79 8 8.625 300 73/4 32.2 200 219.1 20.7 /97 /4.6 10 10.750 300 9 54.1 250 2/3.1 2u1 229 24.3 12 12.750 300 10 70.0 300 1 323.9 1 20] 1 254 31.9 I-- PROJECT INFORMATION APPROVAL STAMP Project: J Approved Address: EjApproved as noted Contractor: []Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 c®us OLPM LISTED APPROVED For Listings/Approval Details and Limitations, visit our website at w.anvilintt.com or contact an Anvil' Sales Representative. INVIL Reducing Coupling F~~ The Model RC-2 Reducing Coupling makes it possible to directly connect two different pipe sizes, eliminating the need for two couplings and a reducing fitting. The specially designed reducing coupling gasket with a center rib assures proper positioning of the gasket and prevents the smaller pipe from telescoping into the larger during assembly. Working pressure ratings shown are for reference only and are based on schedule 40 pipe. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. Model RC-2 Coupling complete with Grade "E" EPDM Gasket. Reducing Coupling Housing Gasket Gasket Center Rib HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 ANSI BOLTS & HEAVY HEX NUTS: Heat treated, oval-neck track head bolts conforming to the physical properties of SAE J429 Grade 5 with a minimum tensile strength of 120,000 psi and heavy hex nuts of carbon steel conforming to ASTM A-563 Grade A, or J995 Grade 2 Bolts and nuts are provided zinc electroplated as standard. METRIC BOLTS & HEAVY HEX NUTS: Heat treated, zinc electroplated oval-neck track head bolts made of carbon steel with mechanical properties per ISO 898-1 Class 8.8. Hex nuts and bolts are zinc electroplated followed by a yellow chromate dip. COATINGS: El Rust inhibiting paint Color: ORANGE (standard) F1 Hot Dipped Zinc Galvanized (optional) QOther available options: Example: RAL3000 or RAL9000 Series For other coating requirements contact an Anvil Representative. LUBRICATION: 0 Standard Gruvlok 0 Gruvlok XtremeTM required For freezer applications. GASKETS: Materials Properties as designated in accordance with ASTM D-2000. 0 Grade "E" EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services. NOT FOR USE IN PETROLEUM APPLICATIONS. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address:[]Approved as noted Contractor: Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 Reducing Coupling ANVIL F~~ II II 6 NO :I.1REDUCING COU jUl Nominal I Larger I Smaller Max. Max. End Range of ' Deflection From ' Coupling Dimensions Coupling Bolts Specified Torque § Approx. Size 0. D. 0. D. Working PressureA Load Pipe End Separation WI. Ea. p Coupling Pipe - X - V Z Oty. Size Mm. Max. In1DN(mm) In/nun InJmm PSI/bar Lbs./kN In 1mm Degrees In/Ft. - mm/rn In/mm In./mm In/mm In/mm Ft.-lbs./N-m L6s.I%'g 2 x 1/2 2.375 1.900 300 1,329 0-1/32 00 45' 0.16 31/8 5 '/a I '/a 2 1/2 x 21/4 80 110 2.0 50x40 60.3 1 48.3 20.7 5.19 00.79 /3.1 92 149 48 - AI276 110 150 0.9 21/2 x 2 2.875 2.375 300 1,948 0-'/32 00 37 0.13 41/4 6% 1% 2 /2 x 2/4 80 110 3.5 65150 730 60.3 20.7 8.67 0-0.79 ______ /0.9 108 162 48 - MI276 I/O /50 /6 300 2 2.996 2.375 300 2,1/5 0--' 036' 0.12 4 61' 111 2 2" 80 /10 3.3 76 x 60 76.1 60.3 20.7 9.41 03.2 9.9 108 1 162 48 1 - M12 x 76 110 150 1.5 3 x 2 3.500 2.375 300 2,886 0-½2 00 31 0.11 41/8 1 l'/8 11/8 2 1/2 x 2/i 80 110 4.4 8050 88.9 60.3 1 20.7 1284 1 6i79 89 124 /8/ 43 - Mi2i76 1/0 1 150 2.0 3x2½ 3.500 2.875 300 2,886 0-Vu 0°31' 0.11 41/s 71/8 11/8 2 ½x2/4 80 110 4.1 80105 88.9 730 20.7 /2.84 0-0.79 8.9 124 181 48 /412.i76 /10 150 1.9 3x309 3.500 2996 300 2,886 0 03/' 0.1/ 6i 7 1" 2 x2•. 80 1/0 4.0 88 X 76 88.9 76.1 20.7 12.84 0-3.2 8.9 124 181 48 M12 x 76 110 150 1.8 4 x 2 4.500 2.375 300 4,771 0-/32 10 12' 0.25 61/4 8/8 2 2 % x 31/2 100 130 8.9 100.50 /143 603 20.7 1 22 22 0-2.38 20.8 /59 225 51 1 Mi6.95 /35 175 4.0 4 x 21/2 4.500 2.875 300 4,771 0* 10 12' 0.25 61/4 8'/8 2 2 1/8 x 31/2 100 130 7.9 i0063 1/43 /30 267 21.22 0-2.38 1 20.8 /59 225 51 /A16.i95 135 175 1 3.6 4 x 3 4.500 3.500 300 4,771 0-%2 10 12' 0.25 61/4 81/8 2 2 1/8 x 31/2 100 130 6.7 100x80 2/4.3 80-9 20.7 21.22 0-2.38 20.8 159 225 51 - 4116.t95 135 175 3.0 4x300 4.500 2996 300 4,771 0'. 212' 025 61'i 813 2 2 013 /00 /30 76 114 X 76 114.3 76.1 20.7 21.22 0-4.8 20.8 159 225 51 M16 x 95 135 175 3.5 5.0.6! Y 4 5.500 4500 300 7,128 0-. /58' 0.20 7 10- 24 2 x41 /00 130 /1.4 139X 114 1 139.7 114.3 20.7 31.71 0-4.8 10.8 184 270 1 54 1 - M20 115 1 135 175 1 5.2 5 x 3 5.563 3.500 300 7,292 01/4 10 58' 0.20 71/4 101/a 21/8 2 3/4 x 41/2 130 180 10.4 /25180 1413 88.9 207 32.44 0-6.4 10-8 184 270 54 20;, 115 175 245 4.7 5 x 4 5.563 4.500 300 7,292 0-Yuu 1°58 0.20 7114 101/8 2% 2 3/494% 130 180 11.4 125' 100 141.3 114.3 20,7 32.44 0-2.38 /6.8 /84 '270 54 - M20x(13 /75 245 5.2 6. OD. .i3 6,500 3500 300 955 0-' 120' 0,26 8' II'. 24 2 '4' 130 /80 /50 165 X 88 165.1 1 88.9 20.7 1 44.28 0-6.4 18.2 210 1 295 54 - M20 x 115 175 1 245 6.8 6'00.4 6500 4500 300 9,955 /20' 026 8; 11'. 2.. 2 -o4l 230 i80 13 165 Xli 4 165.1 114.3 20.7 44.28 0-6.4 18.2 210 295 54 - M20 x 115 175 245 1 6.2 6 x 4 6.625 4.500 300 10,341 0-%2 00 49' 0.17 81/4 11% 21/8 2 3/4 x 4'/2 130 180 13.4 150 A 100 1683 /143 207 4600 0-238 14.1 210 295 54 - 6120o /5 175 245 6.1 6 x 5 6.625 5.562 300 10,341 0-3/32 00 49 0.17 81/2 111/8 2% 2 /4x4½ 130 180 13.5 150o /75 168.3 1 /413 20.7 1 46.00 0-2.38 14.1 2/6 293 54 1420.4 /15 /75 245 6.1 8 x 6 8.625 6.625 300 17,528 0-/32 00 37' 0.13 10/2 14 2¼ 2 ½ x 4½ 130 180 17.7 200x /50 2/91 1683 20.7 /7.97 0-238 /0.9 267 365 37 - Al/Os 1/5 175 245 80 8s6'0D 8,62c 6500 300 17,520 0 (137' 0/3 10..: /42 2 2 '4'; 130 180 ta.9 219 X 165 219.1 165.1 20.7 77.97 0-6.4 10.9 1 267 365 57 - M20x 115 175 245 1 8.3 Not for use in copper systems. Range of Pipe End Separation and Angular Deflection values are for roll grooved pipe and may be doubled for cut groove pipe. See technical data section for coupling data chart notes. § - For additional Bolt Torque information see Technical Data Section. A - Working Pressure Ratings are for reference only and booed on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Other sizes available, contact an Anvil Representative. FP-9.1 2 c®us LISTED APPROVED (0 ~~ For Listings/Approval Details and Limitations, visit our website at wems.anvilintl.com or contact an Anvil5 Sales Representative. iNVI L Cap E to E 't GROOVED Is! Nominal 0 D End Approx. Size to End wt. Ea. In./DN(mm) In/mm In/mm Lbs1Kg 1 1.315 1¼ 0.3 25 33.4 25 0.1 11/4 1.660 1 0.4 32 42.2 25 02 1'/2 1.900 1 0.5 40 48.3 25 0.2 2 2.375 1 0.7 50 6 0. 3 25 0.3 21/2 2.875 1 1.0 65 730 25 0.4 3 0.0 3.000 10.9 76.1 1 76.1 25 0.4 3 3.500 1 1.5 80 88.9 25 0.1 4 4.500 1/16 2.7 /00 /11.3 27 1.2 5 5.563 11 /16 4.4 125 1 /413 27 2.0 499 6500 1 5.5 165.1 165.1 25 2.5 6 6.625 1½6 6.6 /50 168.3 27 30 8 8.625 13A6 11.3 200 1 2/9/ 30 3/ 10* 10.750 1% 21.0 250 273 1 1 32 0.3 12* 12.750 1¼ 35.5 300 3239 32 1 /61 CAST FITTINGS: Ductile Iron conforming to ASTM-A536 COATINGS: DRust inhibiting paint Color: ORANGE (standard) or SHot Dipped Zinc Galvanized conforming to ASTM A-i 53 (optional) EOther available options: Example: RAL3000 or RAL9000 Series Supplied as Style K-i only. PROJECT INFORMATION APPROVAL STAMP Project: ]Approved Address: LJApproved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: FP-4.12 ® Listed Max. Horizontal Load System NPS Sch. 30"44" 45".59" 59"9" 90" 1 -1 1/2" .1Q4. J1 1956 2394 2765 2"- 4" 7013831 2765 - 1383 1956 2304 2765 10-40 1383 t 1956 1 2394 2765 10" 10-40 1383 1956 1 2394 2765 12" toNo 70 2645 1 3238 1 3740 <> Certified Max. ASD Horizontal Loads System NPS 1-1 Sch. 30"-44" 45"-59" 60"-74" 75"-90" 1/2 10,40 1680 2380 29201 3250 2-3" 10,40 1800 2350 3120 3490 4" 10,40 1 7 1930 2370 2640 5,6,8" 10,40 730 1040 12701 1420 * SPECIALLY LISTED PIPE A ST Pipes PVT LTD Al Jozeera Steel Products Co. SAOQ Allied Tube & Conduit Corp. Bihar Tubes LTD. Bluesteel Servtces L L C Borusan Mannesmann Bnnu AS Ball Moose Tube Co. Conares Metal Supply LTD. Hui Chin Worldwide LTD Hickman Pipe & Tube Corp. Jiedong Economy Development Testing Zone Jindul industries LTD Jotindta Steel & Tubes LTD Minul Canada Inc. MS Pipe Co. LTD Northwest Pipe Co. Pacific Pipe Public Co. LTD Subs Thai Steel Pipe Public Co. LTD Shield Fire Safety & Security LTD Sarya Roshini LTD Swautik Pipes LTD Ten-Tube Co. Universal Tube & Plastic Industries LTD Weifang East Pipe Indus"Technical Co. LTD Welded Tube . Berkeley LLC Wheatland Tube Co. WI, Div. Yielt Phai Enterprise Co. LTD Youngstown Tube Co. Zenith Bids (India) LTD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 035 SWAY BRACE FITTING MODEL K Eli 5 thru 12 inch pipe SIZE -SYSTEM PIPE: Nominal Steel 1" thru 12" * Steel Specially listed - see chart. CPVC 1"thru3". Brace common O.D. - Copper, Plastic, FRP, Ductile and Cast Iron SIZE - BRACE PIPE: 1" thru 2" Sch. 40 Mm. 11/4" required for 12" system pipe MATERIAL - Carbon steel and ductile iron. FINISH - Plain or E.G. PATENTS - No. 7,516,922 No. 7,523,895 LISTING/APPROVAL - 203A EX 2625 LISTED .€'" FM Approved -1950 OSHPD See Website. FUNCTION - Lateral fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 and CPVC manufacturers instructions. Load rating - see chart. ASSEMBLY - See drawing. Combine with proper AFCON components- see disclaimer below. Insert brace pipe through bores to achieve minimum 1" extension. Tighten 035 set screws until heads bottom out. FEATURES * Patented - designed for system pipe of varying material. * Improved assembly - extra large bore for brace pipe. * Visual inspection, verifies proper installation. * Superior load ratings. ORDERING - Part #, size - system pipe, size - brace pipe and finish. * COMMONLY KNOWN AS SCH. 7 Special Note: Thin wall sprinkler pipe has a propensity for damage to its circumference resulting in egging. When condition exists - shift mounting location. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss olbasinens or profit, when non-AFCON products have been, or are used. £1 3/13 'JAc!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 077 ATTACHMENT FITTING LOCKING 17/32' WI 17 SIZE - BRACE PIPE: 1" and 1 1/4" Sch. 40 MATERIAL - Carbon Steel, Ductile Iron or S.S. (Type 304). FINISH - Plain or E.G. LISTING/APPROVAL - CLUSUSTEa 203AEX2625 FM Approved - 1950 OSHPD See Website. FUNCTION - Structure attachment fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 FM 2-8. Load rating - see chart. ASSEMBLY Combine with proper AFCON components- see disclaimer below. Insert brace pipe thru fitting near pivot bolt. Tighten set bolt until head contacts bracket. FEATURES * Swivel allows attachment at any angle. * Visual inspection, verifies proper installation. * Larger fastener hole available.- Consult factory. ORDERING - Part #, size - brace pipe and finish. Max. Horizontal Load Size 1-2 ® Ductile Base 2015 1500 Steel Base 2015 Specific AFCON products arc exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hunger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or are used. 3/13 Part #077......... 78 P.O. Box Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 411 SWAY BRACE FITTING SIZE - SYSTEM PIPE: Nominal Pipe Size 1" - 12" Steel - Sch. 40 1 1/4" - 12" Steel - Sch. 10 MATERIAL - Carbon Steel FINISH - Plain or E.G. PATENT - No. 7,140,579 LISTING/APPROVAL cus 203A-EX 2625 APPROVED FM Approved - 1950 OSHPD See Website. ® Listed Max. Horizontal Load System NPS Sch. 30"-44" 45".59" 60"-89" 90" 1" -11/2 1383 1956 2394 2765 2"- 4" _740_ 1383 1956 2394 2765 5"- 6' 1956 2394 2765 8" j 1383 1956 2394 2765 10" 10-40 1383 1956 2394 2765 12" 10-40 1870 2645 3238 3740 FUNCTION - Longitudinal fitting of an AFCON sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. INSTALLATION - Per these instructions including NFPA 13 or FM 2-8 Load rating - see chart. ASSEMBLY - Se drawino. Certified Max. ASO Horizontal Load System NIPS 1-1 Sch. 30"-44" 45"-59" 60"-74" 750-90" 1/2 10-40 420 510 570 2" - 3" 7 -40 860 1030 1150 7-40 860 1030 1150 7-40 950 1150 1280 7-40 2220 2220 3040 8"1 10-40 1340 1620 1810 Combine with proper AFC ON components- see disclaimer below. Align brace member parallel to face of 411 bolt flanges. Tighten 411 bolts until flanges are flat to flat. FEATURES * Patented - design eliminates bending of ears during installation. * Patented - design prevents over tightening on system pipe. * Improved assembly - ears connected for superior strength. * Visual inspection - proper installation when 411 bolt flanges are together. ORDERING - Part #, size - system pipe and finish. Specific ,4FCON products are exclustvcly destgned lobe contpattble ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - .4FCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. .4FCON shalt NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential dantages of any kind, including but not limited to lass of business or proftt. when non-,4FCON products have been, orate used. 5/13 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org SWAY BRACE ADAPTER SIZE -SYSTEM PIPE: See Chart. MATERIAL - Carbon Steel. FINISH - Plain or E.G. PATENT - No. 6,334,285 LISTING/APPROVAL - c®us 203A-EX 2625, 203-EX 2551 LISTED FM Approved -1950 OSHPD OPA-0601 See Website FUNCTION - Sway brace adapter for an AFCON sway brace assembly. Designed to attach to the horizontal flanges of a steel structural membi Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Additionally listed as an 8" hanger attachment. INSTALLATION - Per NFPA 13 and these instructions. Load rating - see chart. Combine with proper AFCON components- see disclaimer below. The structural members design will dictate specific attachment criteria ASSEMBLY - See drawing. Insert 1/2" x 1 1/4" attachment bolt in 086 bracket. Install 1/2" studs if brackets and engage on steel flange. install nuts on studs finger tighi additionally tighten 11/2 turns or torque to 40ft. lbs. Attach AFCON sway brace assembly on 1/2" bolt. * Studs, fasteners and bolt furnished by customer FEATURES * Fits 1/4" thru 1 1/4" flange thickness. * Studs capture head of bolt, providing hold back. * Alternative to center loading beam clamp. ORDERING - Part # and finish. Specific AFCON products arc exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or banger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or arc used. 11/11 !Acsn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 REVERSIBLE BEAM CLAMP 3/4" MOUTH SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. SIZE - ROD: 1/2" SIZE - SYSTEM PIPE: 8" max. MATERIAL - Ductile iron. FINISH - Plain, E.G. and H.D.G. LISTING/APPROVAL - Cus203_EX 2551 FM Approved FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on steel flange - thickness less than 3/4". Set bolt up or down. ASSEMBLY/ATTACHMENT - See drawing. Torque - 3/8= 60 inch lbs. or 1/2= 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 1/4 turn. Caution - Do not over tighten set bolt. FEATURES * Maintains CONSTANT HANGER CENTER-LINE, with set bolt up or down. * Flat throat back to prevent twisting on structure during installation. ORDERING - Part #, rod size and finish. 11/09 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 162 UNIVERSAL RESTRAINING STRAP Nut optional, if insufficient rod dimension K' SIZE- One size fits both 3/8" and 1/2" rod or set screw. Available lengths 4" and longer. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c\?!7/us 203-EX 2551 PATENT - No. 5,897,088 FUNCTION - To enhance hanger attachment in areas subject to Earthquakes. INSTALLATION - Install tight to structure and component parts Minimum return on strap: F' L-dimension is measured from hanger rod center to the strap end. FEATURES * Fast installation for new construction or retrofit. * Requires no hanger disassembly to install. IMPORTANT NOTE: "No Nut Is Required" When installed tight to structure and component parts. (See drawings provided) ORDERING - Part # and L-dimension. 1/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 680 EYE ROD NOT WELDED LENGTH B A SIZE ROD A B MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650w 3/8 7/16 21/2 210 1/2 9/16 21/2 395 5/8 13/16 21/2 630 3/4 1 1 3 945 7/8 11/8 31/2 1315 1 11/4 4 1735 11/4 11/2 1 5 2800 11/2 2 6 4070 1 3/4 21/4 7 5490 2 21/2 8 7240 21/4 23/4 9 9520 21/2 3 10 11725 NOTE: "A' dimension should not be 1/16" larger than fastener. Please notify factory if larger "A" dimension is needed. SIZE - 3/8 thru 7/8 inch rod. MATERIAL - Carbon Steel. FINISH - Plain, E.G., H.D.G. and S.S. FUNCTION - For attaching to and hanging from wood beams where bolting through beam is desired. ORDERING - Part #, rod size, length, width of bend and finish. *POSSIBLE ALTERNATE = PART #535 SEE CUT SHEET 1/08 WFAc!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch Pipe LISTED FOR STEEL/CPVC 1/2 & 3/4 inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mil. Galvanized to G-90 spec. LISTING/APPROVAL - C®8S LISTED 203 EX 2551 1"- 8" Approval guide - 1"- 8" OSHPD OPA-060 1 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MS S-SP-5 8 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WT. 5 WT.+250 UL TEST LOAD 1 3/8 3075 403.75 750 1114 3/8 43.95 469.75 750 11/2 3/8 54,15 520.75 750 2 3/8 76.95 634.75 750 21/2 3/8 118.30 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349,45 1 1996.75 2000 6 1/2 1 476.35 2631.75 2650 8 1/2 1 711.00 3805.00 4050 PIPE A B 1.8793 1 2.5259 11/4 2,1392 2.7850 1112 2.2673 2.9140 A B 2 2.6048 3.2516 1 21/2 3,412, 4,1150 3 3+7845 4.4311 ". •// _i_ .L1118 8.3290 1 551 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part#and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER -A FCON will NOT warrant against the failure of its products when used in combination with other products, ports or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or amused. A 11 1/08 JAc P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 650 ALL THREADED ROD 10'- O' LENGTHS ROD SIZE MAX. REC. LOAD LBS. FOR SERVICE TEMP. 650°F 750°F 1/4 240 215 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 1 4960 4420 1 1/4 8000 7140 11/2 11630 10370 NOTE; maximum Temperature: 750°F SIZE - 1/4 thru 1 1/2 inch rod in 10' - Ø!I lengths. MATERIAL - Carbon Steel. FINISH - Plain and E.G., ORDERING - Part #, rod diameter and finish. 12/10 SIZE - ROD: 3/8" SIZE - SYSTEM PIPE: 4" max. MATERIAL - Carbon Steel. FINISH - Plain, E.G. and S.S. LISTING/APPROVAL - C®uS LISTSD 203-EX 2551 øØf 1 2.0312 ø I 1 3/8 1,1.250 1-7 Special Note: The purlin lip is not capable of supporting NFPA 13 fire sprinkler pipe at 1(wt.) +250 lbs mm. When purlin manufacturers specify 200 lbs. max. ® Locations I t, BorE 3@ A -C.E ® ® 24 B-E 3@ B-U-F ® 2@0 A-C 4@ A-C-U-F P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 551 REVOLVER TAPPED BRACKET PATENT - No. 6,568,642 FUNCTION - Attachment component of an AFCON hanger. To support horizontal piping. INSTALLATION - Per NFPA 13 and these instructions. Install on vertical mounting surface. ASSEMBLY/ATTACHMENT - See drawing. Center mounting hole accepts 3/8" and 1/2" fasteners. *FASTENER LOCATION OPTIONS - See chart. Vertical - Hangs plumb from first fastener. Stops wood splitting along the grain. Horizontal - When vertical space is limited. c®us FASTENERS PER NFPA 13 LISTED FOR STEEL PIPE - SEE TABLE. FEATURES * Universal fastener array for enhanced mounting. * Radius -Tapped orifice: Aligns rod for easy thread engagement and eliminates structural deficiencies associated with rod inserts. * No speed/pal nuts required. ORDERING - Part # and finish. MOUNTING FASTENERS LISTED Wood Steel — 1/4 or #14 Tek Steel — #10 SMS or #905 Fastener Qty. Steel Mm. Qty. Steel Mtn. Qty. Steel No Pre-Drill Pipe Thickness Pipe Thickness Pipe 1/4x1 1/2 LB 1 2 14 GA. 1 3 18 GA. 1 2½ 24 24 2 3 #14 x 1 V2 SMS 1 2 16 GA. 1 2 '/2 3 4 2 4 2 4 20 GA; 2 3 #l6x2CIS 2 2 18 GA. 1 2/2 4 4 3 4 2 3 22 GA. 3 3 Wood - Thru 5/8" Gyp. 3 4 2O GA. *1 2 1/4 x 2 LB I 2 B ONLY 2 3 SMS =Sheet Mewl Screw 2 4 3 4 DS Drive Screw #14x2SMS 1 2 LB=L,513o11 24 22 GA. 3 2 '/2 GypDypsu,rvBoard 5111 SAMMYS® FOR WOOD No pre-drilling required. Quick to install using the Sammy Nut Driver with an 18V cordless drill/driver. Saves time from traditional methods. Reduces installation costs. Manufactured in the U.S.A. -. Watch a ,Jdao dec,ocst,ahoc at www.itwbuildex.com i - #14 Black Nut Driver Part # 8113910 i #14 SW Red Nut Driver Part # 8114910 1/4' 8002957 GST 100 1/4 210 (7/16" OSB) 25 125 670 (3/4" Ply) 1/4" 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 3/8" 8007957 GST 10 1/4 x1" 210 (7/16" OSB) 300 25 125 670 (3/4" Ply) 3/8" 8008957 GST 20 1/4x2" 1760 (Fir) 850 1475 25 125 3/8" 8068925 GST 20-SS 1/4x2" 1760 (Fir) 850 25 125 3/8" 8009925 GST 25-380 ' 3/8x2-1/2" 2113 (Fir) 1500 25 125 . 3/8" 8010957 GST 30 1/403" 2060 (Fir) 1500 1475 25 125 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) 25 125 1/2" 8013925 GST 2 1/4 x 2" 1760 (Fir) 25 125 1/2" 8015925 GST3 1/4x3" 2275 (Fir) 25 125 r*j V (r- UMJUFACTUREO USA SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. APPROVALS 8007957 GST 10 3/8' Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 318" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST 20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST 20-SS 318" Vertical 2-1/2" 850 1-1/2" 8010957 GST 30 318" Vertical 4" 1500 1-112" 4" 1475 1-112" 8009925 GST 25-380 318" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8" Horizontal 3-1/2" - 4" 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3"" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-112" 4" 1475 1-1/2" ]112Y1le1I 8038957 DSTR 1 3/8" Vertical 1500 .035" 4" 1475 .105" 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR 1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK 50 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 2" 940 .029 4" 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 2" 940 .029" 4" 1475 .125" 8294922 SXP 20 3/8" Vertical or up 1045" 2" 750 .027" 2" 635 .029 8295922 SXP 35 3/8" Vertical or up 1089" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .060" I SAMMYS FOR CONCRETE. PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 318" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000p5i 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC s35 PCF (lbs/It) Part 'Number i fl Size Direction Rating (lbs) Thickness SAMMYS FOR STEEL FITTING 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45" 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060" 90" 80 .060" 8293957 Part SWXP 35 Rod 3/8" Mount UL Load Horizontal UL Min. Steel 80 .060" Number SAMMYS FOR Model STEEL ,CONDUIT, Size TUBING,; Direction Rating (lbs) AND CABLE Thickness Listed Application 8150922 XP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat No. C-Z2000 Plenum Rated, Complies wl NEC Standards SSheetteel Gauges Gauge No. 22 ga. 20 ga. 18 ga 16 ga. 14 ga. 12 ga. 118" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" "SWG 25-300 Maximum pipe size in composite wood joist allowed by UL is 3-1/2" UL compliance with NEC Standards. "SWG 25-380 Maximum pipe size in wood limber or joist allowed by UL is4 UL and FM texts were performed in compliance with NFPA 13 Standards. "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" Fastening requirement: 5 limes weight at water-filled schedule 40 250 pipe plus pounds. "SWG 20 Maximum nine size in wood limber on ioisl allowed by UL is 3" Traditional methods for installing branch line restraints in fire sprinkler systems are cumbersome and time-consuming. Contractors often cut (and re-cut) threaded rod to precise measurements to restrain the sprinkler pipe with a loop hanger and surge restraint. Traditional methods also commonly require five or more parts per restraint. To avoid these labor-intensive methods, ERICO has streamlined the process and developed the Branch Line Restraint System, part of the CADDY® line of hanging and bracing solutions for the fire protection market. Ideal for restraining 1" (25 mm) through 2" (50 mm) branch lines, this innovative system is significantly faster and easier to install than current methods. It attaches directly to steel bar joists, I-beams or purlins, as well as concrete and wood structures. The hardware is installed with only one tool, a 5/16" (8 mm) socket drill driver, which provides significant labor savings and convenience. It features a simple, two-step installation process, allowing a time savings of up to 80% compared to other methods. Unlike most solutions that only accept 3/8" (M10) threaded rod, the versatile Branch Line Restraint System features a swivel attachment that can be rotated to accept 3/8" or 1/2" (M10 or M12) threaded rod. This allows greater restraint distances from the pipe to structure with 1/2" (M12) threaded rod. The system meets the requirements of NFPA® 13, making it ideal for new construction applications. The total system is cULus® Listed and FM® Approved, and has been pre-approved by the state of California (OSHPD OPA-2629-10). Features Complete restraint system is quick and easy to install Offers up to 80% time savings per branch line restraint Eliminates need to cut threaded rod to exact dimensions Works with 3/8" and 1/2" (M10 and M12) rod Capable of restraint distances up to 40" (960 mm) from pipe to structure with 1/2" (M12) threaded rod Meets requirements of NFPA® 13 section 9.3.6 Branch Line Restraint Pipe Attachment www.erico.com 1 ERICD Branch Line Branch Line Restraint Branch Line Restraint Restraint Structure Structure Attachment Structure Attachment Attachment to Steel to Wood/Concrete to Threaded Hole www.erico.com 2 ERIC Features Accepts 3/8" or 1/2" (M 10 or M12) threaded rod Quick grip clamp simplifies measuring and cutting of threaded rod Works with rough-cut threaded rod and eliminates pipe-side deburring Can be installed with threaded rod above or below the service pipe Shear-off head helps ensure correct torque and simplifies inspection Specifications Material: Steel Finish: Electro-galvanized c®us A''JAIg[(SX(.1II 41 Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to steel members with self-drilling/tapping screw Specifications Material: Steel Finish: Electro-galvanized c®us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. NNNJ LT Features Swivel connector accepts 3/8" or 1/2" (MiD or M12) threaded rod Attaches to wood or concrete structures J I 'I Specifications Material: Steel Finish: Electro-galvanized c® us Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. www.erico.com 5 - RICO Features Swivel connector accepts 3/8" or 1/2" (M10 or M12) threaded rod Attaches to concrete anchors or structural attachments with female threads Specifications Material: Steel Finish: Electro-galvanized i?" C®US Branch line structural attachments are for restraint only and not for the hanging of fire sprinkler piping. cULus is a registered certification mark of UL L-C. FM is a registered certification mark of FM Approvals LLC, LTD. NFPA is a registered trademark of National Fire Protection Association, Inc WARNING ERICO products shall be installed and used only as indicated in ERICO's product instruction sheets and training materials. Instruction sheets are available at www.erico.com and from your ERICO customer service representative. Improper installation, misuse, misapplication or other failure to completely follow ERICO's instructions and warnings may cause product malfunction, property damage, serious bodily injury and death. WARRANTY ERICO products are warranted to be free from defects in material and workmanship at the time of shipment. NO OTHER WARRANTY, WHETHER EXPRESS OR IMPLIED (INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCTS. Claims for errors, shortages, defects or nonconformities ascertainable upon inspection must be made in writing within 5 days after Buyers receipt of products. All other claims must be made in writing to ERICO within 6 months from the date of shipment or transport. Products claimed to be nonconforming or defective must, upon ERICO's prior written approval in accordance with its standard terms and procedures governing returns, promptly be returned to ERICO for inspection. Claims not made as provided above and within the applicable time period will be barred. ERICO shall in no event be responsible if the products have not been stored or used in accordance with its specifications and recommended procedures. ERICO will, at its option, either repair or replace nonconforming or defective products for which it is responsible or return the purchase price to the Buyer, THE FOREGOING STATES BUYER'S EXCLUSIVE REMEDY FOR ANY BREACH OF ERICO WARRANTY AND FOR ANY CLAIM, WHETHER SOUNDING IN CONTRACT, TORT OR NEGLIGENCE, FOR LOSS OR INJURY CAUSED BY THE SALE OR USE OF ANY PRODUCT. LIMITATION OF LIABILITY ERICO excludes all liability except such liability that is directly attributable to the willful or gross negligence of ERICO's employees, Should ERICO be held liable its liability shall in no event exceed the total purchase price under the contract. ERICO SHALL IN NO EVENT BE RESPONSIBLE FOR ANY LOSS OF BUSINESS OR PROFITS, DOWNTIME OR DELAY, LABOR, REPAIR OR MATERIAL COSTS OR ANY SIMILAR OR DISSIMILAR CONSEQUENTIAL LOSS OR DAMAGE INCURRED BY BUYER. Copyright © 2012 ERICO International Corporation. All rights reserved. CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH, and LENTON are registered trademarks of ERICO International Corporation. 1 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (10 1mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6' (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120 VAC I2VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX- I deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -301 to 150°F (-340 to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .1 7A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .1 7A 94 78 6(150) I20VAC PBAI2O6 1806120* .05A 92 83 8(200) I20VAC PBAI208 1808120* .05A 99 84 10(250) I20VAC PBAI2010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. AWARNING1 In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-I PAGE I OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2 conduit entrance DWGII 776.2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Wiring (rear view) Fig. I Fig. 3 A.C. BELLS 0" WHITE (IN) WHITE (OUT) FROM CONTROL PANEL OR (250) (150) PRECEDING BELL BLACK 1(N) BLACK (OUT)_____________ CAUTION: 2 1/16 RE ' WHEN ELECTRICAL SUPERVISION IS QU SHOWN.ED USE IN AND OUT LEADS AS SHOWN. (68) DWO# 776-I NOTES: I. WHEN USING AC BELLS. TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. D\VG# 776.3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90' AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). àWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 VSR ® POPUM VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Specifications subject to change without notice. Ordering Information Nominal Pipe Size Model Part Number DN50 VSR-2 1144402 2 1/2' DN65 VSR-2 1/2 1144425 DN80 VSR-3 1144403 31/2' - VSR-3 1/2 1144435 DNIOO VSR-4 1144404 - VSR-5 1144405 DN15O VSR-6 1144406 8' DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit, stock no. 0090148 Replaceable Components: Retard/Switch Assembly, stock no. 1029030 General Information The Model VSR is a vane type waterfiow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8' (50 mm thru 200 mm). LPC approved sizes are 2" thru 8" (50 mm thru 200 mm). See Ordering Information chart. The VSR may also be used as a sectional water/low detector on large systems. The VSR contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. UL, CUL and CSFM Listed, FM Approved, LPCBApproved, For CE Marked (EN12259-5) / VdS Approved model use VSR-EU Service Pressure: 450 PSI (31 BAR) - UL Flow Sensitivity Range for Signal: 4-10 GPM (15-38 LPM) - UL Maximum Surge: 18 FPS (5.5 m/s) Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 1251250VAC 2.0 Amps at 3OVDC Resistive 10 mAmps mm. at 24VDC Conduit Entrances: Two knockouts provided for 1/2" conduit. Individual switch compartments suitable for dissimilar voltages. Environmental Specifications: NEMA 4/IP54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature Range: 40°F - 120°F, (4.5°C - 49°C) - UL Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA- 13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 WARNING Installation must be performed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. I CAUTION I Waterfiow switches that are monitoring wet pipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Waterfiow switches used for this application may result in unintended discharges caused by surges, trapped air, or short retard times. Enclosure The VSR switches and retard device are enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin number 5401103 for installation instructions of this switch. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 www.pottersignal.com PRINTED IN USA MFG. #5401146 - REV L PAGE I OF 4 3/09 A VSR ® POTTER VANE TYPE WATERFLOW P_ The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 6" (15 cm) of a fitting which changes the direction of the waterfiow or within 24' (60 cm) of a valve or drain. NOTE: Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill (see Fig. I). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Take care not to damage the non-corrosive bushing in the saddle. The bushing should fit inside the hole in the pipe. Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1). The vane must not rub the inside of the pipe or bind in any way. A CAUTION Do not trim the paddle. Failure to follow these instructions may prevent the device from operating and will void the warranty. DO NOT LEAVE COVER OFF FOR Retard Adjustment Fig. I EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from 0 to the max setting (60-90 seconds). The time delay should be set at the minimum required to prevent false alarms 7>- TIGHTEN NUTS " ALTERNATELY MOT ON PIPE SO ARROW ON SADDLE POINTS IN DIRECTION i OFWATERFLOW CAUTION Hole must be drilled perpendicular to the pipe and vertically centered. Refer to the Compatible Pipe/Installation Requirements chart for size. Correct Incorrect 0 3 -E2E~- I DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW (Flowing water activates device in one direction only.) OWn. 1146-11 ADAPTER1QADAPTER 20m,s*2nam MAX. DNSO ONLY USE (2) 5180162 ADAPTERS AS SHOWN ABOVE DWGI 1146-117 Compatible Installation _Pipe/ _Requirements Model Nominal Pipe Size Nominal Pipe O.D. Pipe Wall Thickness Hole Size U-Bolt Nuts Torque Schedule 10 (UL) Schedule 40 (UL) BS-1387 (LPC) DN (VDS) inch mm inch inns inch mm inch mm inch mm inch mm inch mm fl-lb n-in VSR-2 2 DNSO 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 1.25 +.125/-.062 33.0 ± 2.0 20 27 VSR-2 1/2 2.5 - 2.875 73.0 1 0.120 3.05 1 0.203 5.16 1 - - - - VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 1 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 2.00± .125 50.8±2.0 VSR-3 1/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - VSR-4 4 DNIOO 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 3.2 VSR-5 5 - 5.563 141.3 0.134 3.40 1 0.258 6.55 - - - - VSR-6 6 DNISO 6.625 168.3 0.134 3.40 L.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 1 0.322 8.18 0.248 6.3 0.177 4.5 NOTE: For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG. #5401146 - REV L PAGE 2 OF 4 3/09 Fig. 2 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. Lo TICE Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Fig. 3 Break out thin section of cover when wiring both switches from one conduit entrance. LIM Fig. 8 GREEN GROUND 4 ® POTTER The Symbol of Protection VSR VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD Fig. 4 Switch Terminal Connections Clamping Plate Terminal l51GOI 0 DWG. #46-1 A WARNING An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8 of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. Fig. 5 Typical Electrical Connections BELL Notes: The Model VSR has two switches, one can be used to operate a central POWER SOURCE station, proprietary or remote signaling unit, while the other contact POWER is used to operate a local audible or visual annunciator. A condition of LPC Approval of this product is that the electrical E~l IISTIIABLEFORBELL entry must be sealed to exclude moisture. ft LOW For supervised circuits, see "Switch Terminal Connections" T ZONE drawing and warning note (Fig. 4). 0 jfJRO . REPANEL ma 114.12 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's test valve shall always be used for test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the VSR is not recommended or advisable. A minimum flow of 10 GPM (38 LPM) is required to activate this device. Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig. 7 Mounting Dimensions 3.50 in 2.00 (89.0 mm 234it J f (508 (59.4 mm) PIPE DI A. U-BOLT NUT _ + 5.25 in U-BOLT WASHER / - \ PIPE SADDLE (+1334mm) PLASTIC DWG 114e44 NOMINAL PIPE WA. +1.75 in (+44.5 MM) FOR DN 50- DN 652-2.5 in NOMINAL PIPE DIA. +2.125 in (+54.0 MM) FOR DN 80- DN 200 3-8 in PRINTED IN USA MFG. #5401146- REV L PAGE 3 OF 4 3/09 VSR A Polum VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterfiow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable. In the unlikely event that either component does not perform properly, please order replacement retard switch assembly stock #1029030 (see Fig. 6). There is no maintenance required, only periodic testing and inspection. Retard/Switch Assembly Replacement (See Fig. 6) The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterfiow switch from the pipe Make sure the fire alarm zone or circuit connected to the waterfiow switch is bypassed or otherwise taken out of service. Disconnect the power source for local bell (if applicable). Identify and remove all wires from the waterfiow switch. Remove the (2) mounting screws holding retard/switch assembly to the base. Do not remove the (2) retard housing screws. Remove the retard assembly by lifting it straight up over the tripstem. Install the new retard assembly. Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. Re-install the (2) original mounting screws. 8. Reconnect all wires. Perform a flow test and place the system back in service. Fig 6 REMOVE (2) ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH -'ZASSEMBLY TO BASE BREAK OUTTHIN SECTION OF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2) ORIGINAL MOUNTING I CREWS RETARD/SWITCH RETARD/SWITCH ASSEMBLY AU (2) LOCATING PINS fl i DO NOT REMO\ (2) RETARD HOI. SCREWS (2) LOCATI1 BOSSES IN I DWG# 1146-10 Removal of Waterfiow Switch To prevent accidental water damage, all control valves should be shut tight and the system completely drained before waterfiow detectors are removed or replaced. Turn off electrical power to the detector, then disconnect wiring. Loosen nuts and remove U-bolts. Gently lift the saddle far enough to get your fingers under it. With your fingers, roll the vane so it will fit through the hole while continuing to lift the waterfiow detector saddle. Lift detector clear of pipe. PRINTED IN USA MFG. #5401146 - REV L PAGE 4 OF 4 3/09 - nrc USTED APPROVED SPECIFICATIONS Range: 0-300 PSI (Inside) 0-2000 Kpa (Outside) Accuracy: ±3-2-3% ASME B40.100 Grade B Burdon Tube: Phosphor Bronze Window: Polycarbonate one-piece ring and crystal Dial: Galvalume Pointer: Aluminum, painted black Case: PGE Xenoy® DX2735 Connection: Brass, 1/4" ANPT LM DIMENSIONS (29.5) 1.16 IN MAX1 0 0 3.46 (MM) I-- (87.9) 0 3.88 0 3:70 (940) (986) (14.2) T 39±03 .-1/4-1SANPT 44±04 :ijiicP'tI (ti !A I I I i M ffb"i I I 111 !A FIT!_ fl ri 11 ITC 100 Quaker Lane, Malvern, PA 19355 • Phone: 610-240-4900 • Fax: 610-240-4906 • www.testandrain.com The AGF Manufacturing, Inc. Model 7500 Pressure Gauge is an FM Approved/UL Listed 4" gauge designed for use on "wet" sprinkler systems. The AGF Model 7500 has been designed to meet the requirements specified in NFPA 13, 2007 Edition Chapters 7.1.1.1 - 7.1.1.2, 7.2.1 -7.3.1.3,7.8.7,8.16.1.2.2, and 8.17.3 The AGF Manufacturing, Inc. Model 7600 ¼" 3-Way Globe Valve is a UL Listed valve designed to connect the pressure gauge to the sprinkler systems. The AGF Model 7600 has been designed to meet NFPA 13 System Attachments stating, "...each gauge shall be equipped with a shutoff valve and provision for drainage." MODEL 7500 PRESSURE GAUGE WITH MODEL 7600 GLOBE VALVE AND ¼ STEEL PLUG I _ iI_li.'xi1 Gtuitllinj MADE IN U.S.A. AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Job Name: Architect: Engineer: Contractor: TESTasORAIN is a registered trademark of AGF Manufacturing Inc. SS-7500 2/14 THE MODEL 7500 PRESSURE GAUGE AND MODEL 7600 3-WAY GLOBE VALVE ARE ALSO USED ON THE FOLLOWING AGF PRoDucTs: TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. II zfcj vii '1 ;T11I Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve The AGF Model 1011A TESTANDRAIN provides the test and express drain functions for wet fire sprinkler systems on mu it: story installations requiring pressure relief (NFPA 13 and NFPA 13R). 'The Model 1011A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 10I1A is available in a full range of sizes ( to 2) with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (UL/FM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: 3/8" (2.8K), 7Ae" (4.2K), ½ (5.6K), 17/3211 (8.0K), /8" (11.2K, ELO), 3/4"(14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. CC CC OliOfli 0 note iliet he ?C-C.0r0tCJ 01 00CC 'V0 C 3C0CCe or. Cr :0iIrcl rC3qe cC prorsuro or orhe ops rC onc c'os; CCC Oc_FO of vC..\C0 00 reroCrc o EcCEN p one r pe000ro :hroe COP oo PC 1 C3iInri The CO.vi50 iC:O; enGred CC. Of POOh odo:o POP ci rno POmp, Tn CNN vrdve eOoC:o hr ncrrPco s rCCeN 'coosrOOr 1j n cC venanco Gore rThorfd no Cr ken Oaf hr elOr: \aoo to 'soCCecC 'crn the cstc:n rhe Ta system 0: coerstOOr.. A rOOsT 'ave aec,crd COVO H hs a rrhiotC VrICVO or a fcCJp .Jownstrear CC 55 SS-M1011A_V001 06/13 TESTANDRAiN' is registered trademark of AGF Manufacturing Inc. SIZE A B C D E F G H 3/4" 79A6 11/2" 23/16 3/8" 33/8 49A6 63/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 7A6" 11/2" 2A6" 3/8" 33/8 ' 113A6" 4A6" 6/8" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715A6" 111A6" 2/16" 41/4' 3%" 115/16" 5/16" 71/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½" 816" 113A6" 31/4" 51A6" 3/8" 25/8" 81/4" 1O/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815A6" 113A6 31/4" 51A6" 3/8" 25/8 ' 81/4" 1O/8" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) Model 1011 - Plan View Model 1011 A C USTED ® TESTAN DRAIN® Model 1011 A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other setting available Dimensions Model 1011 - Front View The Model 1011 provides the following... TO t B flom the 2013 Edition of NFPA 13 DRAIN + - - Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. I t Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - C & 8.16 2.4.3 shull be provided with a drain connection having a minimum size as shown iii Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Orifice Sizes Chapter A.8.17.4.2 (Wet Pipe System) test connection is permitted to terminate into a t4' Fl drain capable of accepting full flow.. using an approved sight test and K25— connection containing a smooih bore corrosion-resistant orifice giving a flow equivalent to one spnnkler. Chapter 8.17.4.2.2 The test connection valve shall he accessible, Materials Chapter 8.17.4.2.4 shai) be permitted tone installed in any location... (Jownstrearn of Handle.. ...... ........Steel the waterf]ow alarm. Stem... ................ Rod Brass Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1' in Ball .... ...... .. ....... .OP. Brass diameter, terminating III a smooth bore corrosion--resistant orifice, Body .......... .........Bronze to provide a flow equivalent to one sprinkler Valve Seat ....... ....Impregnated Tef)on' Chapter 8.17.4.3.2 The trio test connection.., with a shutoff valve arid plug not less Indicator Plate.... Steel than 1", at least one of which shall he brass Relief Valve.. ....... Bv,-)i)ze Chapter 7. 1.2 - a vie.t pipe system shall be provided with a listed relief valve set Bypass Fittings... Brass to operate at 175 PS) or 10 PSI in excess of the maximnuni system Bypass Tubing....Nylobraid pressure, whichever is greater. Chapter 8 16 1 2.3 A listed relief valve of not less than ½ in size shall be provided on Approvals the discharge side or the pressure-reducing valve set to operate at UL and UIC Listed: Chapter A.8.16.1.2.3 a pressure riot exceeding rated pressure of the system. - consideration should Le qivr. to piping the discharge from the 'EX4019 &EX4a3\ lOressure relief', valve FM Approved NYC-BSA No, 720-87-SM MADE IN U.S.A. 1111.1Patent 1E 474136and OtherPatents ZTIiiI AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com Available on 1 ' to 2 so: nrs only • "A'.,a'iyi:- to or 1/, ono ...zc .....,i cr iy Job Name: Architect: Engineer: Contractor: I & Description Manufactured from .020" white coated aluminun are screen printed with a fade resistant red ink. Each sign is shipped with a clear protective plastic coating which can be re- moved at time of installation. Each sign type meets or exceeds NFPA13 requirements. All signs (except 7" round) are drilled in four corners to allow for easy installation. All signs (except 7" round) may be installed with sign chain or with any fastener that is suitable for the material that the sign is being attached. The 7" round bell signs are center drilled to allow for installation di- rectly to the bell gong assembly. Type "A" 9" x 7" Control valve signs are drilled with the same four hole pattern as Type "B" 6" x 2" signs to allow for attachment of Type "B" to Type "A". Specifications Material: .020' aluminum with removable plastic coating Sizes: x 2" x 6" x 7" 9" x 7" 12" x 10" 8.5" x 11" Installation Installation of aluminum signs is accomplished by several methods. The most common installation procedure is to use #16 Single Jack chain to hang the sign on the area being identified. Since all of the above mentioned signs are predrilled at all four cor- ners, the last link of the chain can be opened and hooked through the top holes on the signs and hung on the ap- propriate valve or piping. The signs may also be fastened to a flat surface with fasteners appropriate to the base mate- rial. (The 9" x 7" Fire Alarm Bell sign must be drilled if it is to be attached directly to the bell gong.) See current catalog for a full listing of all available signs. ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FPPI 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions; 1 800 344-1822 1 800 344-3775 fax www.fppi.com FIRE SPRINKLER RISER INSIDE Sprinkler Identification Signs FPPI's Sprinkler Identification Signs are manufactured of aluminum, painted white then printed with "fade resistant" red ink. Each sign is drilled for easy installation and is plastic coated to prevent scratching of finish during shipment and final installation. Designed in accordance with NFPA requirements. Part•tI[._ I1I[.]i Box Qty. 02-002-00 Blank Sign w/border 6" x 2" 1000 02-006-00 Air Control, 6" x 2" 1000 02-010-00 Air Line, 6" x 2" 1000 02-014-00 Alarm Line, 6" x 2" 1000 02-018-00 Alarm Test, 6" x 2" 1000 02-022-00 Anti-Freeze System 6" x 2" 1000 02-023-00 Anti-Freeze System 5" x 7" 1000 02-024-00 Auto Sprinkler Shut-Off 12" x 10" 1000 02-026-00 Auxiliary Drain, 6" x 2" 1000 02-034-00 Control Valve, 6" x 2" 1000 02-036-00 Control Valve, 4" x 6" 1000 02-037-00 Control Valve, 5" x 7" 1000 02-038-00 Control Valve, 9" x 7" 500 02-042-00 Drain, 6" x 2" 1000 02-046-00 Drain Valve, 6" x 2" 1000 02-050-00 Dry Standpipe 6" x 2" 1000 02-051-00 Fire Dept. Connection 6" x 2" 1000 02-053-00 Excess Pressure Pump, 6" x 2" 1000 02-054-00 Entire System, 6" x 2" 1000 02-055-00 Fire Alarm Bell, 9" x 7" 500 02-056-00 Fire Alarm Bell, 7" Round 500 02-057-00 911 Fire Alarm Bell, 7" Round 500 02-058-00 F.S. Valve Do Not Close, 6" x 2" 1000 02-060-00 Fire Sprinkler Riser Inside, 6" x 2" 1000 02-062-00 From City Main, 6" x 2" 1000 02-066-00 In This Building, 6" x 2" 1000 02-070-00 In This Section, 6" x 2" 1000 02-074-00 Inspectors Test, 6" x 2" 1000 02-077-00 Hydraulic System, 5" x 7" 1000 02-081-00 Hydraulic System, 8-1/2" x 11" 1000 02-082-00 Main Control, 6" x 2" 1000 02-086-00 Main Drain, 6" x 2" 1000 02-091-00 Multi-use System, Warning, 5" x 7" 1000 02-092-00 Normally Closed, 6" x 2" 1000 02-096-00 Normally Open, 6" x 2" 1000 02-098-00 Open Sprinkler, 6" x 2" 1000 I---- - __ ___ RINKLER SHUT-OFF VALVE LOCATED OPPOSITE THIS SIGN SPRINKLERS THROUGHOUT Ill BUILDING ©1996-2009 Fire Protection Products, Inc (FPPI) Fire Protection Products, Inc FP p i 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax www.fppi.com Installation Select the correct Spare Sprinkler Head Cabinet in accordance with the Automatic Sprinkler Systems Handbook. As per the 1989 Edition the correct number of spare sprinkler is as follows: "0-300 sprinklers, not less than 6 300-1000, not less than 12 1000 or more, not less than 24. Stock of spare sprinklers shall include all types and ratings installed.* Once the correct Spare Sprinkler Head Cabinet has been select- ed, installation is accomplished by inserting the correct fastener in each of the two holes inside the cabinet, securing the cabinet securely to the wall. The insert the correct number and type of sprinklers in accordance with the "handbook". *Final determination is subject to approval by the AHJ. Storage Cabinet Description Fire Protection Products, Inc. Spare Sprinkler Head Cabinets are designed to allow for spare sprinkler head storage as required by NFPA guidelines. The Spare Sprinkler Head Cabinets are available in six configurations. Three head, six head, six head ESFR, twelve head, twenty-four head and thirty-six head. All six styles are manufactured with "knockouts" to accommodate the most common size sprinklers. The shelf is located to allow for the storage of a typical sprinkler head wrench. Each cabinet is finished with a red enamel fi fish. Each spare head cabinet comes with a hinged door which remains closed to protect the spare sprinklers from the elements and features two holes on the back panel to allow for attachment to most surfaces utilizing the appropriate fasteners. Not intended for exposed or harsh environments. Specifications Material: Painted plain steel Finish: Red enamel Styles: 3 Spare sprinklers, 1/2 or 3/4 6 Spare sprinklers, 1/2 or 3/4 6 Spare, ESFR, 1/2 , 3/4 or 1" 12 Spare sprinklers 1/2 or 3/4 24 Spare sprinklers 36 Spare sprinklers Fire Protection Products, Inc 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 ©2000-2007 Fire Protection Products, Inc (FPPI) For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fppi.com ECS Ejector Automatic Air Vent (PAV-W) C rim ]EE1 Specifications Stock Number: PAV-W PAV-WS (Supervised) Service Pressure: Up to 175 PSIG System Connection: 1" NPT Male Temperature Range: 40°F to 120°F (4.5°C to 49°C) Dimensions: 14"(L) X 7"(D) X 7"(H) Weight: 8 Lbs Clear Height: 5" APPROVED • Patented redundant float design eliminates piping to a drain Support Hanger Not Required U.S. Pat. No. 8,636,023 General Description The ECS Ejector Automatic Air Vent (PAV-W/WS) is a device that provides automatic venting of trapped air in wet pipe fire sprinkler systems. As a fire sprinkler system is filled with water, trapped air migrates to the high point of the system near the vent installation location which allows for trapped air to be vented. Trapped air contains oxygen which is the primary cause of corrosion in fire sprinkler systems. Corrosion in wet pipe fire sprinkler systems is directly proportional to the amount of oxygen trapped within the system piping, so a reduction in trapped air will in turn reduce the internal corrosion activity of the fire sprinkler system. Venting the trapped air in a wet pipe sprinkler system can also decrease water delivery time and reduce false water flow alarms. The [CS Ejector Automatic Air Vent must be installed as shown on the engineering design documents, if a location is not provided install the vent at an accessible high point on the fire sprinkler system remote from the system riser where gas can be vented and at a location that the pressure gauge provided for visual monitoring can be viewed from directly below. The PAV-W/WS is also equipped with brass components that allows the device to be installed in areas subject to external corrosion. The float mechanism on the [CS Ejector Automatic Air Vent will automatically close when water reaches the vent and the redundant design eliminates the need to plumb the PAV-W/WS to drain. If the primary air vent valve allows any significant amount of water to leak past the second air vent valve will close preventing water from discharging and provide a system pressure reading on the pressure gauge. This condition will be an indication that the primary automatic gas vent valve has failed and requires service or replacement. The pressure gauge is designed to be visible from the floor below the ECS Ejector Automatic Air Vent from a distance of approximately 30 feet. There are two available models of the [CS Ejector Automatic Air Vent: the PAV-W and the PAV-WS. The units both operate as described previously, but the PAV-WS includes a wiring connection to a monitoring circuit. A single contact rated 24VAC/DC @ 2A for electronic monitoring with an end of line resistor (EOLR) must be installed according to the wiring diagram in Figure 1 to electronically monitor the PAV-WS. A notification from the PAV-WS indicates that the pressure gauge on the bottom of the vent assembly has a system pressure reading due to a failure of the primary float valve which renders the ECS Ejector Automatic Air Vent inoperable. Engineered Corrosion Solutions 11336 Lackland Road St. Louis, M063146- Phone 1-314-432-1377• www.ecscorrosiofl.com ECS EJECTOR AUTOMATIC AIR VENT April 2016- Rev 3 1 Installation Instructions Maintenance Instructions I The ECS Ejector Automatic Air Vent is equipped with an isolation ball valve to be connected to the fire sprinkler system. Once the PAV-W/WS has been assembled at the provided union (see Figure 1), the contractor shall install a 1" outlet (welded or mechanical) to connect the vent assembly to the sprinkler system. Install the PAV-W/WS vent assembly at the location provided by the engineering design documents in a level position at an accessible high point on the sprinkler system where trapped gas can be vented. NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. 3 When electronic supervision is specified the PAV-WS must be utilized instead of the PAV-W (see Figure 1) and an addressable monitor module with an end of line resistor must be provided in accordance with NFPA 72. 4. Inspection of the vent assembly should be performed after installation and hydrostatic testing of the fire sprinkler system. Inspection should be performed periodically thereafter in accordance with the applicable NFPA codes and standards and/ or the authority having jurisdiction. NOTE: Patented redundant float design eliminates piping the PAV-W to a drain FIGURE 1 — Wiring Diagram INSTALLATION NOTES: 1. If Monitored By The Building Fire Alarm System, Provide One Addressable Monitoring Module To Monitor The fl$ Sspph,d,,jth Ejector Automatic Air Vent. 2. connect The Ejector Automatic Air Vent To The Addressable Monitor- ing Module. 3. Supervise The Circuit Using An End-Of -Line (E.O.L.) Resistor In Accordance With NFPA 72. M!t MOth i N,l Add -W The ECS Ejector Automatic Air Vent shall be inspected annually at minimum. While isolation ball valve is in the open position check for air/water leaks. Check the pressure gauge on the bottom of the vent assembly for a system pressure reading. If a system pressure reading is detected the primary vent valve may require service or replacement. While isolation ball valve is in the closed position the inspection must check for blockage in the "'i" strainer and the discharge orifice. Ooeratine Instructions Once the fire sprinkler system has been hydrostatically tested, open the isolation ball valve on the PAV-W. Trapped gas should be expected to immediately vent from the device if the system has been re-filled with water. The isolation ball valve shall remain in the open position to allow for venting of any additional trapped gas remaining in the system that may migrate to the vent location. Water traps that would restrict operation of the ECS Ejector Automatic Air Vent can be cleared by closing the isolation ball valve and removing the "Y" strainer plug. Once the water trap has been removed, replace the "Y" strainer plug and reopen the isolation ball valve. Gas Vent Valve Replacement Plumbing the PAV-W/WS to drain is not required. Occasionally during venting operations a small amount of water may leak past the primary gas vent valve and collect in the intermediate plumbing. This is considered normal and not a failure of the valve. However, if inspection reveals a system pressure reading then the primary vent valve may require replacement. Please contact Engineered Corrosion Solutions for replacement parts and instructions. Engineered Corrosion Solutions• 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 2 1" Connection to Sprinkler System must NOTE: Patented redundant float design eliminates piping vent to drain. Figure 2 - ECS Ejector Automatic Air Vent Outline Drawing Primary and Seconds Gas Vent Valves "Y" Strair Pressure Gauge Figure 3 - ECS Ejector Automatic Air Vent Installed on Sprinkler System NOTE: Piping to the vent assembly cannot be installed in a configuration that would trap water and prevent drainage to the sprinkler system; a water trap impedes the ability of the vent to remove gas from the fire sprinkler system. Engineered Corrosion Solutions 11336 Lackland Road St. Louis, MO 63146 Phone 1-314-432-1377 www.ecscorrosion.com ECS EJECTOR AUTOMATIC AIR VENT April 2016 - Rev 3 En. ine8ra ) TM ECS uorrosi on L, son* I MIN Complete Corrosion Control.