Loading...
HomeMy WebLinkAbout799 PINE AVE; ; FPC2021-0124; PermitPERMIT REPORT (pty of Carlsbad Print Date: 11/01/2021 Job Address: 799 PINE AVE, CARLSBAD, CA 92008-2428 Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: 2041000600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: CITY OF CARLSBAD SENIOR CENTER - BACKFLOW PREVENTER REPLACEMENT Permit No: FPC2021-0124 Status: Closed - Finaled Applied: 07/06/2021 Issued: Finaled Close Out: 11/01/2021 Inspector: Final Inspection: Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MICHAEL LOVELY 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (8S8).444-2000 (858) 444-2000 x1727 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $756.00 Total Payments To Date: $756.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov Hydraulic Calculations by HydraCALC Cosco Fire Protection, Inc. 4990 Greencraig Lane C-16 577621 San Diego, CA 92123 858-444-2000 Job Name : CARLSBAD SENIOR CENTER BACKFLOW - BOR Drawing : FP-100 Location : 799 ORION WAY Remote Area : BOR Contract : 10.CD_6024 Data File : SENIOR CENTER BOR CALC.WXF Computer Programs by Hydratec Inc. Revision: 50.5520.727 Cosco Fire Protection, Inc. Page 1 CARLSBAD SENIOR CENTER BACKFLOW - BOR Date 7-6-21 HYDRAULIC CALCULATIONS for JOB NAME CARLSBAD SENIOR CENTER BACKFLOW - BOR Location 799 ORION WAY Drawing# FP-100 Contract # I 0.CD_6024 Date 7-6-21 DESIGN Remote area # BOR Remote area location BASE OF RISER CALC Occupancy classification OFFICE Density .10 - Gpm/SqFt Area of application 1506 - SqFt Coverage/sprinkler Actual Area - SqFt Type of sprinkler calculated N/A # Sprinklers calculated N/A In-rack demand N/A - GPM Hose streams 100-GPM Total water required (including hose streams) 345.479 - GPM @ 54.5187 - Psi Type of system NFPA 13 Volume of system (dry orpre-action) N/A - Gal WATER SUPPLY INFORMATION Test date 7-5-21 Location PINE AVE. AND JEFFERSON ST. Source of info H60774 CONTRACTOR INFO COSCO FIRE PROTECTION Address 4990 GREENCRAIG LANE I / SAN DIEGO, CA 92123 Phone # 1-858-444-2000 Name of designer MJ LOVELY Authority having jurisdiction CARLSBAD FIRE NOTES: Base of riser proof calculation for new backflow 1 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Water Supply Curve Cosco Fire Protection, Inc. Page 2 CARLSBAD SENIOR CENTER BACKFLOW - BOR Date 7-6-21 City Water Supply: Demand: Cl - Static Pressure : 80 Dl - Elevation : 1.083 C2 - Residual Pressure: 63 D2 - System Flow :245.4 C2 - Residual Flow : 3725 D2 - System Pressure : 54.559 Hose ( Demand) :100 D3 - System Demand :345.4 Safety Margin : 25.232 150 140 130 p120 R° E10° S 90 Cl S 80 U 70 . R6° E 50 40 30 20 10 - 406"800 1200 1600 .2000 2400 2800 3200 3600 FLOW ( NA 1.85 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Fittings Used Summary Cosco Fire Protection, Inc. Page 3 CARLSAb SENIOR CENTER BACKFLOW - BOR Date 7-6-21 Fitting Legend Abbrev. Name 1/2 % 1 1% 1% 2 21/a 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 I NFPA I39O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zie Wilkins 375 Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.5520.727 ,.FjQv'LSummary - NFPA Cosco Fire Protection, Inc. Page 4 CARLSBAD SENIOR CENTER BACKFLOW - BOR Date 7-6-21 SUPPLYANALYSIS Node at Static Residual Available Source Pressure Pressure Flow Pressure Total Demand Required Pressure TEST 80.0 63 3725.0 79.791 345.4 54.559 NODE ANALYSIS Pressure Discharge Node Tag Elevation Node Type at Node at Node Notes BOR 4.0 42.76 245.48 UGI -4.0 46.83 UG2 -4.0 47.29 BFI 2.0 44.88 BF2 2.0 53.37 UG3 -4.0 56.16 UG4 -4.0 56.88 UG5 -4.0 56.89 TEST 1.5 54.56 100.0 Computer Programs by Hydratec Inc. Revision: 50.5520.727 Final Calculations: Hazen-Williams Cosco Fire Protection, Inc. Page 5 CARLSBAD SENIOR CENTER BACKFLOW - BOR Date 7-6-21 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf ** BOR 4 +245.48 245.40 4 L 8.72 8.000 140 42.762 to 2E 29.067 37.787 3.465 UG1 -4 245.4 4.1 45.787 0.0132 0.606 VeI= 5.96 UGI -4 0.0 4 L 11.534 34.000 150 46.833 to 11.533 0.0 UG2 -4 245.4 4.23 45.533 0.0100 0.456 Vel = 5.60 UG2 -4 0.0 4 L 8.72 6.000 140 47.289 to 8.720 -2.599 BFI 2 245.4 4.1 14.720 0.0132 0.195 Vel = 5.96 BFI 2 0.0 4 Zie 0.0 6.000 140 44.885 to 8.403 * * Fixed Loss = 8.403 BF2 2 245.4 4.1 6.000 0.0132 0.079 Vel = 5.96 BF2 2 0.0 4 L 8.72 6.000 140 53.367 to 8.720 2.599 UG3 -4 245.4 4.1 14.720 0.0132 0.194 Vel = 5.96 UG3 -4 0.0 4 G 3.845 29.500 150 56.160 to 1 38.446 42.290 0.0 UG4 -4 245.4 4.23 71.790 0.0100 0.719 Vel = 5.60 UG4 -4 0.0 12 T 80.498 52.500 150 56.879 to 80.498 0.0 UG5 -4 245.4 11.65 132.998 0.0001 0.009 Vel = 0.74 UGS -4 0.0 6 L 12.911 16.000 140 56.888 to 12.911 -2.382 TEST 1.500 245.4 6.16 28.911 0.0018 0.053 VeI= 2.64 100.00 Qa= 100.00 TEST 345.40 54.559 K Factor = 46.76 Computer Programs by Hydratec Inc. Revision: 50.5520.727 No. 234.b CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Senior Center Backflow Replacement SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 799 Pine Ave CITY: Carlsbad PHONE: (619) 913-2079 FAX NUMBER: (858) 444-2056 Largest Building (ft.2): 35,266 Sprinkled? Yes Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Pine Ave at Jefferson St TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 80 PSI Hydrant Number (if applicable):H60774 Elevation of test: 57 Feet Main Size: 12 INCH Pressure Zone: 241 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3,725 GPM Residual Pressure 63 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi in the vicinity of the fire of 7,225 gpm. However, this exceeds the City's maximum velocity criteria of 10 fps. Therefore, the maximum available fire flow at this location that meets both the maximum velocity and minimum pressure criteria is 3,725 gpm. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer• modeling), fill out the information above as applicable and check here: x Name: Jennifer _R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: _- Title/Org:P6ject! Manakr Date: 07/05/2021 fl:KI: Project Site [' 16 N \,\ Fire Flow Test Location H60774 S N -- -- (3' / < - \ >- ,- 8' -:;i Legend I • w_Hydrant " \ Pipe N ZONE it 241 —r ' 01 #234 Senior Center Backflow Replacement (799 Pine Ave) - Fire Flow Analysis San Diego Branch Office .000000 I cosco 4990 Greencraig Lane .00 0000: San Diego, CA 92123 S...... .• i Fire Protection (858) 4442000 fax: 444-2056 CA Lic.: C-16 #577621 www.coscofire.com MATERIAL SUBMITTAL Date: 07/06/21 Senior Center Backflow Replacement 799 Pine Avenue Carlsbad CA 92008 JOB # 10.CA_5503 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. Submitted by: M. Lovely Los Angeles • San Francisco • Orange 0 Fresno • San Diego • Seattle MODEL WEIGHT W/MAX. SPOOL LENGTH 375ASTR SIZE in. mm WITH NRS GATES (GXF) lbs. I kg WITH OS&Y GATES (GXF) lbs. I kg WITH NRS GATES (GXG) lbs. kg WITH OS&Y GATES (GXG) lbs. kg WITH BUTTERFLY VALVES (GXG) lbs. I kg WITH BUTTERFLY VALVES (GXF) lbs. kg 21/2 65 108 49 126 57 98 44 116 53 95 43 106 48 3 80 127 58 145 66 115 52 133 60 102 46 115 52 4 100 192 87 228 104 172 78 204 93 114 52 136 62 6 150 314 143 372 169 284 129 350 159 186 84 216 98 8 200 627 285 709 322 587 266 655 297 409 186 455 206 10 250 882 1 401 1 978 445 830 376 920 417 1 556 252 614 279 lAr'W1Il ZURN® Model 375ASTR Replacement Reduced Pressure Principle Assembly Application Designed for drop-in replacement of existing longer lay length as- semblies without the need for additional spools or spacers, saving 2 to 6 hours of installation labor and up to 2 machine hours per back- low replacement. A custom sized grooved spool installed between the backflow body and downstream shut-off valve allows customer specified assembly lengths to be shipped directly from the factory. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 375ASTR provides protection where a potential health hazard exists. Standards Compliance ASSE® Listed 1013 AWWA Compliant C511 with gates only), and C550 FM® Approved UL® Classified C-UL® Classified CSA® Certified IAPMO® Listed Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI/CAN 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body 304L Stainless steel Access covers 304L Stainless steel Coatings FDA Approved electrostatic epoxy finish Internals Stainless Steel, 300 Series NORYLTM Fasteners & Springs Stainless Steel, 300 Series Seal rings EPDM (FDA approved) 0-rings Buna Nitrile (FDA approved) Sensing line Stainless Steel, braided hose Dimensions & Weights (do not include pkg.) LEAD FREE PATENT NO. 8,997,772 Options (Suffixes can be combined) D - with flanged end NRS gate valves (standard) El OSY - with flanged end OS&Y gate valves U BG - with grooved end butterfly valves with integral supervisory switch U BF - with flanged end butterfly valves with integral supervisory switch *New Connected Products. Search ZCSM-PF on Zurn.com for details. Accessories O Connected Pressure Monitor (Model ZCSMPF)* 0 Connected Flow Meter Option (Model ZCSM-BTM must be ordered with Model ZCSMPF)* U Repair kit (rubber only) U Thermal expansion tank (Model XT) U OS & Y Gate valve tamper switch (OSY-40) O Air gap (Model AG) U QT-SET Quick Test Fitting Set Features Sizes: 2 1/2', 3", 411, 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged bolt pattern) ASME 1316.42 Class 150 DIMENSION (approximate) MODEL 375ASTR SIZE in. mm A in. mm min max min max A WITH BUTTERFLY VALVES in. mm min 11 max min I max B in. mm c in. mm D in. mm E NRS GATE in. mm E OS&Y OPEN in. mm E OS&Y CLOSED in. mm E BUTTERFLY VALVE in. mm F in. mm G in. mm 21/2 65 34 471/8 864 1197 31 441/8 787 1121 165/8 422 41/2 84111/2292173/4 451 153/8 391 81/4 210 93/4 248 85/8 219 3 80 35 481/8 889 1222311/2445/8 800 1133 165/8 422 41/2 184 123/4 324 201/4 514 17 432 81/2 216 93/4 248 85/8 219 4 100 373/8 621/4 949 1581 325/8571/2 829 1461 165/8 422 41/2 103 141/2 368 221/2 572 181/4 464 9 229 93/4 248 85/8 219 6 150 46 711/4 1168 1810 39 641/4 991 1632 221/4 565 51/2 1M1O 154 18 457 301/2 775 241/4 616 101/4 260 103/4273111/4286 8 200 553/4 86 1416 2184483/4 79 1238 2007 291/2 749 91/4 279 211/8 537 37 940 281/2 724 181/2 470 155/8 397 131/4337 10 250 585/81005/81489 2556 525/8945/81337 2403 291/2 749 91/4 205 243/4 629 455/8 1159343/4 883 181/2 470 155/8 397 131/2343 Zurn Industries, LLC I Wilkins Rev. N 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Document No. BF-375ASTR Date: 7/20 - In Canada I Zurn Industries Limited Patent No. 8,997,772 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-8925216 Product No. Model 375ASTR www.zurn.com Page 1 of 2 DIRECTION OF FLOW INDOOR INSTALLATION (375ASTR with ZCSM-PF Connected Pressure Monitor and ZCSM.BTM Connected Flow Meter accessories) Flow Characteristics MODEL 375ASTR 2 1/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 ffm 05 0) w o0 0 200 400 600 FLOW RATES (GPM) MODEL 375ASTR 6", 8' & 10" (STANDARDAND METRIC) FLOW RATE (us) 0.0 63.1 126.2 189.3 30 20 0 1000 2000 3000 Rated Flow (established by approval agencies) 50.5 I.)0 CO - 0. - 104 - (I) - Cl) 0 - 69 35 D - C') - (I) w 0. —0 800 252.4 Lu, CD 0 Jd 0•• 138 co =1 0 =1 -J j w - 69 - (6) - Co W 0. 4000 FLOW RATE (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30(762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Order Configuration - Exact in field measurements are required when ordering the assembly. Please have the assembly length ready when ordering. - All assemblies are custom made to order and all sales are final. - Lead time is approximately one week. Generic part number used for ordering: X375ASTR*Y where X= NOMINAL VALVE SIZE (212 REPRESENTS 2-1/2") Y= ASSEMBLY LENGTH SUFFIX: choose A-C from table at right (exact in field measurements must be given to customer service representative) *ADDED OPTIONS (use suffixes designated in Example OPTIONS section on previous page) To order a 4" Model 375ASTR with OS&Y gate valves and an as- sembly length of 52 3/8", the part number would be: 4-375ASTROSY-B. The length of 52 3/8" would be given to Customer Service. Specifications I - The Reduced Pressure Principle Backflow Prevention Assembly shall be certified to NSF/ANSI/CAN 61, ASSE® Listed 1013, and supplied with full port gate valves. The main body and access cover shall be 304L Stainless Steel, the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Principle Backflow Prevention Assembly used for all backflow replacements shall be a ZURN WILKINS Model 375ASTR. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, unit io, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurncom Page 2 of 2 - ASSEMBLY LENGTH SUFFIX A B C Size From Range I To Size Range From I To Size Range From I To NPS 2-1/2" 34" 47 1/8" 50 1/16" 62 1/4" 59 1/16" 711/4" 741/16 86 3 35" 481/8'. 4 37 3/8" 50" 6 46" 59' 8 1553/4" 74" 10" 58 5/8" 77" 77 1/16" 89" 89 1/16" 1100 5/8' 'POTTER /\J ________ Model/Series No. 'U ROEMER CONNECTIONS (FDC) 5710-5734 \\ /D DL'fl EXPOSED FIRE DEPT. INLET SERIES I I I I— CONNECTIONS-CLAPPER TYPE Member of Morris Group International" -------------------- ... - - SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER, 300 PSI RATED Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4" x 2-1/2" x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER, 175 PSI RATED Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. MODEL SELECTION PRODUCT OPTIONS TWO-WAY WITH SINGLE CLAPPER U 5710 Back Outlet (UL Listed) 4 FM li 1j 5715 Angle Outlet (UL Listed) 4 F TWO-WAY WITH DOUBLE CLAPPER Ii 5721 Back Outlet Li 5722 Back Outlet Ii 5723 Back Outlet Li 5724 Back Outlet U 5731 Angle Outlet U 5732 Angle Outlet Li 5733 Angle Outlet U 5734 Angle Outlet FINISHES: Li -B Polished Brass lJ -C Rough Chrome Plated Body Ii -D Polished Chrome Plated THREADS: Li N.S.T. U Other_ LETTERING AVAILABLE: Li AUTO. SPKR. Li STANDPIPE Note: Refer to Model Dimensional Chart for UL & FM Listing Call Potter Roamer - Fire Pro for current listings and approvals. Dimensions are subject to manufacturers tolerance and may change without notice. Potter Roamer- - - FIRE EQUIPMENT MANUFACTURERS ON,,SA4 POTTER RO EM ER/F IRE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of void or - ASSOCIATION .....,.,. P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roamer- Fire Pro, -, City of Industry, CA Chicago (800) 547-3473 Member of Morris Group International "' Please visit potten-oemer.com for most current specifications. - - NAFED Los Angeles Area Miami (866)961-3473 - 91744 U.S.A. Atlanta (800) 762-0542 Dallas (866) 644-3473 51105134 SERIES Date: 12/11/18 - Ui!9 - NPA F ! 800-366-3473 . 626:8554890 www.potterroemer.com WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov L\J POTTER 1 Model/Series No. RF ME 5710-5734 ( EXPOSED FIRE DEPT.INLET SERIES CONNECTIONS CLAPPER TYPE Member of Morris Group International- MODEL DIMENSIONS TWO-WAY WITH SINGLE CLAPPER UL Listed File #EX4078 MODEL 5710 - 5715 Model #S201B <> APPROVED TWO-WAY WITH DOUBLE CLAPPER Outlet Approvals Outlet Approvals Size A #6(3314 B C D Back Model No. c®us LISTED #6(3314 Angle Model No. c®us LISTED 5721 Yes 5731 Yes 4x2-1/2x2-112 7-1/2 11-1/2 8-1/2 11-1/2 5722 Yes 5732 Yes 6 x 2-1/2 x 2-1/2 9-1/2 10-1/2 9 10-3/4 5723 Yes 5733 Yes 4 x 3 x 3 9-1/2 11-1/2 9-1/2 11 5724 Yes 5734 Yes 6 x 3 x 3 10 11 10-1/2 11 7-1/4" MODEL 5721 - 5734 UL Listed File #EX3314 Model #A105 Call Potter Roemer - Fire Pro for current listings and approvals. Dimensions are subject to manufacturers tolerance and may change without notice. Potter Roemer - FIRE NT MA NUFACTUREQUIPME E ONFSA ASSOCIATION POTTER ROE ME R/FI RE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of void or P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roemer- Fire Pro, i, City of Industry, CA Chicago (800) 547-3473 Member of Morris Group International Please visit ' potterroemer.com for most current specifications. ru J /\ 9 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 800-366-3473 Dallas (866) 644-3473 51105134 SERIES Date: 12/11/18 NFPAa \'1 bhs 626-855-4890 www.potterroerner.com J Il1agIe Building essentials for a better tornorrow Nzz; ~-, BLUE BRUTE TM SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4. 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 1 8.20 12.88 10.1 12 13.20 12.08 0.528 1 8.80 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 1 11.10 9.79 0.617 1 8.20 13.57 13.9 12 13.20 11.65 0.733 1 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 1 9.42 0.793 8.20 14.27 17.6 12 13.20 1 11.20 0.943 8.80 16.97 25.1 Consult JM Eagle for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. Assembly Mark Product Standard: ANSI/AW\NA C900 Pipe Compound: ASTM Dl 784 Cells Class 12454 Gasket: ASTM F477 Integral Bell Joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length Installation: AWWA C605 JM Eagle Installation Guide I.D. Inside Dameter O.D. Outside Diameter T. Wall Thickness Bell Outside Diameter E: Distance between Assembly Mark to the end of spigot. BITUMINOUS COATING: ...................... ANSI/AWWA C1 04/A21.4-08 CEMENT LINING' ..........ANSI/AWWA C104.A2 1.4-08, Double cement lining available EPDXY COATING: .......... ANSI/AWWA Cl16/A21.16-09 Note: Epoxy coated fittings are available to the specification required for your application(s) BARE: ............................. Available BOLTS: ........................... ANSI/AWWA C 1 1/A21.11-7 INSTALLATION: .............Per AWWA C600-99 using pipe conforming to ANSI/AWWA C151/A21.51-02 I TYLER UNION® Quality Waterworks Products 23U - Mechanical Joint C1 53/A21.53 Compact Revised 10/09 SU8P&0T3jrL%k (Current Revisions for All Standards Apply) SIZES' ............................2" through 48" (2" Not Referenced in C153/A21.53) STANDARDS: ................. ANSI/AWWA C153/A21.53-06 and NFPA 3"-12" UL Listed (EX2 111) Note: Cast with tested and traceable ASTM A536 Ductile Iron PRESSURE RATING: 2"- 24" rated @ 350 PSI; 30"- 48" & all fittings with Flanged branches rated @ 250 PSI Note: With use of special flange gasket 2"-24" flanged fittings can be rated @ 350 psi Note: Compact Wyes over 12" are not pressure rated. Contact manufacturer for rating in your application. DEFLECTION: ................. Upon completion of installation, Mechanical Joint fittings 2"-12" are rated for a maxi- mum of 50 deflection and 14"-48" a maximum of 3° deflection NSF-61. ......................... Meets all requirements, UL Registered (2"-48") JOINT DIMENSIONS IN INCHES BOLTS Size A Dia. B C Dia. D Dia. F Dia. J Dia. K' Dia. K2 Dia. I M S I X Size No. 3 3.96 2.50 4.84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 3/ %x3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 3/4X31/2 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 /8 3/4X31/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 /8 3/4x4 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 /8 3/4x4 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 /8 3/4X4 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .55 .47 3/4x4l/2 10 16 17.40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .58 .50 /8 3/4x41/2 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 3/4x41/2 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 /8 3/4x41/2 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 /8 3/4x5 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1Y8 1x6 20 36 38.30 4.00 39.59 39.76 38.47 43,75 46.00 46.00 1.45 2.00 1.00 .74 1Y8 1x6 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1% 1'/4x6½ 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1/s 1¼x6½ 32 Tyler Pipe Company. 11910 C 492 • Tyler, Texas 75706 • (800) 527-8478 Union Foundry Company. 1 501 W. 17th Street • Anniston, Alabama 36202 • (800) 226-7601 www.tylerunion.com MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION Sizes 3" thru 12" UL Listed For Fire Main Equipment SAMPLE SPECIFICATIONS Mechanical Joint watermain fittings with accessories, 3" through 48" shall be manufactured from Ductile Iron in accordance with and meet all applicable terms and provisions of standards ANSI/AWWA C153/A21 .53 ANSI! AWWA C1 1/A21.1 1 (current revisions). Ductile Iron Mechanical Joint Fittings 3" through 24" shall be rated for 350 PSI working pressure. 30" through 48" shall be rated for 250 psi working pressure. Flanged ductile-iron fittings in 24-in. (610 mm) and smaller sizes may be rated for 350 psi (2,413 kPa) with the use of special gaskets. All coated fittings meet requirements of NSF-61. NOTE - EXCEPTIONS: Mechanical Joint Fittings with flanged branches are rated for water pressure of 250 PSI. NOTE: Fittings are CEMENT LINED and seal coated in accordance with ANSI!AWWA Cl 04/A21.4; also available double cement-lined, bare or epoxy coated. K2 j I JOINT DIMENSIONS IN INCHES BOLTS Size A Dia. B C Dia. D Dia. F Dia. i Dia. K' Dia. K2 Dia. L M S I X Size No. 3 3.96 2.50 4,84 4.94 4.06 6.19 7.62 7.69 .58 .62 .39 .33 3/ 5/sx3 4 4 4.80 2.50 5.92 6.02 4.90 7.50 9.06 9.12 .60 .75 .39 .34 7 3/4X3½ 4 6 6.90 2.50 8.02 8.12 7.00 9.50 11.06 11.12 .63 .88 .43 .36 7/ 3/4x3'/2 6 8 9.05 2.50 10.17 10.27 9.15 11.75 13.31 13.37 .66 1.00 .45 .38 /8 3/4X31/2 6 10 11.10 2.50 12.22 12.34 11.20 14.00 15.62 15.62 .70 1.00 .47 .40 /8 3/4X3½ 8 12 13.20 2.50 14.32 14.44 13.30 16.25 17.88 17.88 .73 1.00 .49 .42 /8 3/4x3½ 8 14 15.30 3.50 16.40 16.54 15.44 18.75 20.31 20.25 .79 1.25 .56 .47 "/s 3/4x4 10 16 17,40 3.50 18.50 18.64 17.54 21.00 22.56 22.50 .85 1.31 .57 .50 7/ 3/4x4 12 18 19.50 3.50 20.60 20.74 19.64 23.25 24.83 24.75 1.00 1.38 .68 .54 78 3/x4 12 20 21.60 3.50 22.70 22.84 21.74 25.50 27.08 27.00 1.02 1.44 .69 .57 78 3/4x4 14 24 25.80 3.50 26.90 27.04 25.94 30.00 31.58 31.50 1.02 1.56 .75 .61 78 3/4x4½ 16 30 32.00 4.00 33.29 33.46 32.17 36.88 39.12 39.12 1.31 2.00 .82 .66 1'/a 1x5V2 20 36 38.30 4.00 39.59 39.76 38.47 43.75 46.00 46.00 1.45 2.00 1.00 .74 1Y8 1x5½ 24 42 44.50 4.00 45.79 45.96 44.67 50.62 53.12 53.12 1.45 2.00 1.25 .82 1/ 1'/4X6½ 28 48 50.80 4.00 52.09 52.26 50.97 57.50 60.00 60.00 1.45 2.00 1.35 .90 1/ 1'/4X61/2 32 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 900 Bends (1/4) Dimensions I A R Weight .34 3.5 2.5 19 .35 4.0 3.0 26 .37 6.5 6.0 49 .39 7.5 7.0 64 .41 9.5 9.0 102 .43 10.5 10.0 129 .51 12.0 11.5 214 .52 13.0 12.5 273 .59 15.5 14.0 411 .60 17.0 15.5 519 .62 17.0 15.5 721 .66 21.50 19.0 930 .74 24.50 22.0 1450 .82 29.25 26.7 2205 .90 33.25 30.75 2990 450 Bends (1/8) Dimensions A R Weight 2.00 2.41 17 2.50 3.56 22 3.50 7.25 39 4.00 8.44 56 5.01 10.88 78 5.98 13.25 102 5.50 12.06 155 5.98 13.25 204 6.50 12.36 292 7.00 13.59 372 7.50 14.89 490 10.50 9.31 716 11.50 21.73 1110 14.00 27.76 1610 15.00 30.17 2090 Dimensions A R Weight 1.50 2.51 15 1.75 3.81 20 2.25 6.35 31 2.85 11.80 50 3.35 14.35 66 3.86 16.90 87 3.93 17.25 142 3.98 17.50 178 7.50 30.19 286 8.50 35.19 376 9.00 37.69 512 6.75 21.36 665 7.75 26.39 960 9.00 32.68 1350 10.00 27.70 1760 Dimensions A R Weigh 1.25 2.53 16 1.50 5.12 20 1.50 5.12 29 2.06 15.80 45 2.32 18.36 59 2.56 20.90 82 2.59 21.25 136 2.62 21.50 157 3.00 60.84 283 3.50 71.07 374 3.50 76.12 487 4.75 22.84 600 5.00 25.38 820 6.00 35.54 1180 6.50 40.61 1475 221/2° Bends (1/16) 11¼0 (1/32) Size 3 4 6 8 10 12 14 16 18 20 24 30 36 42 48 Dimensions Weights Size D 1' L MJxMJ MJxPE 4 6 10 -- 45 -- 4 12 16 -- 55 -- 4 18 22 -- 65 -. 4 24 28 -- 75 -- 6 6 12 17.5 41 54 6 12 18 -- 65 -- 6 18 24 -- 75 -- 6 24 30 -- 85 -- 8 6 13 -- 84 -- 8 12 19 -- 90 -- 8 18 25 -- 100 -- -r D MECHANICAL JOINT C153 DUCTILE IRON COMPACT FITTINGS TYLER UNION® Sizes 3" thru 12" UL Listed For Fire Main Equipment BENDS *OFFSETS MJxMJ MJxPE * Not included in AWWA C153. Tyler Utilities Division • 11910 CR 492 -Tyler, Texas 75706 . (800) 527-8478 2 Union Foundry Company • Box 309 0 Anniston, Alabama 36202 • (800) 226-7601 02/01/08 IN y y- 90° Bend Mi x PE (1/4) 450 Bend Mix PE (1/8) 221/2° Bend Mix PE (1/16) 11W Bend Mix PE (1/32) R 45° Bend Mi x Flange (1/8) 221/20 Bend MJxFlange 11 (1/16) ige (1/32) MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION® Sizes 3" thru 12" UL Listed For Fire Main Equipment BENDS Dimensions Dimensions Dimensions Dimensions Size I A Y R Weight A Y R Weight A V R Weight A V R Weight 3 .34 3.5 9.0 2.5 18 2.0 7.5 2.41 17 1.50 7.00 2.51 19 1.25 6.75 7.62 15 4 .35 4.0 9.5 3.0 26 2.5 8.0 3.56 22 1.75 7.25 3.81 20 1.50 7.00 5.12 20 6 .37 6.0 11.5 5.0 45 3.2 8.7 5.49 38 2.25 7.75 6.35 33 1.50 7.00 5.12 32 8 .39 7.5 13.0 7.0 64 4.0 9.5 8.44 55 2.84 8.34 11.80 51 2.05 7.55 15.80 44 10 .41 9.5 15.0 9.0 108 5.0 10.5 10.88 78 3.35 8.85 14.35 66 2.31 7.81 18.36 60 12 .43 9.0 14.4 6.0 114 6.0 11.5 13.25 104 3.50 9.00 12.70 89 2.56 8.06 20.90 79 14 .51 12.0 20.0 11.5 219 5.5 13.4 10.85 165 3.93 11.93 17.25 152 2.59 10.59 21.25 137 16 .52 13.0 21.0 12.5 254 6.0 14.0 13.25 206 3.98 11.98 17.50 181 2.62 10.62 21.50 161 24 .62 17.0 25.0 15.5 710 7.5 16.6 14.69 460 9.00 17.66 37.69 455 9.00 26.12 12.00 475 30 .68 21.5 30.5 -- 865 10.5 19.5 -- 715 6.75 15.75 -- 600 -- -- -- -- 90° Bend Mi x Flange (1/4) Dimensions Dimensions Dimensions Dimensions Size T A R F Weight A R F Weight A R F Weight A R F Weight 3 .34 3.5 2.5 5.5 21 ... ... .. .. ... ... .. .. ... 4 .35 4.0 3.0 6.5 28 2.50 3.56 4.0 34 1.75 3.81 4.0 34 1.50 5.12 4.0 19 6 .37 6.0 5.0 8.0 45 3.25 5.49 5.0 57 2.25 5.35 5.0 57 1.50 5.12 5.0 30 8 .39 7.5 7.0 9.0 73 4.25 7.93 5.5 83 2.50 7.62 5.5 83 1.75 7.70 5.5 50 10 .41 9.5 9.0 11.0 113 5.00 9.76 6.5 122 3.00 10.16 6.5 122 2.00 10.25 6.5 75 12 .43 10.5 10.0 12.0 141 6.00 12.19 7.5 159 3.50 12.70 7.5 159 2.25 12.82 7.5 88 14 .51 12.0 11.5 14.0 217 5.50 10.85 8.5 207 16 .52 13.0 12.5 15.0 280 6.00 12.02 9.5 290 90° Swivel x Swivel Hydrant Eli Dimensions Size I A B C D E F R *Weight .6 .37 10.5 15.5 6.90 11.2 6.81 7.98 6.0 74 * Weight includes two swivel glands. Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company Box 309 Anniston, Alabama 36202 ' (800) 226-7601 3 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment TYLER UNION® TEES CROSS Mi Tee Mi x FE Tee Mi x Swivel Tee Cross Dimensions Weights Size T T H ii J2 P Mi MJxFE fMJxS Cross 3 .34 .34 3.5 3.50 5.5 ... 26 29 ... 31 43 .35 .34 3.5 4.09 6.5 ... 35 34 ... 39 4 .35 .35 4.0 4.00 6.5 ... 36 39 ... 45 6x3 .37 .34 4.0 4.00 6.5 ... 51 54 6x4 .37 .35 4.0 5.00 8.0 ... 52 57 ... 62 6 .37 .37 5.0 5.00 8.0 10.50 66 68 77 79 8x3 .39 .34 4.0 6.50 9.0 ... 56 8x4 .39 .35 4.5 6.50 9.0 ... 72 82 ... 84 8x6 .39 .37 5.5 6.50 9.0 11.50 79 81 105 98 8 .39 .39 6.5 6.50 9.0 11.50 90 101 116 112 10x3 .41 .34 4.0 7.50 11.0 ... 80 10x4 .41 .35 4.5 7.50 11.0 ... 82 92 ... 98 10x6 .41 .37 5.5 7.50 11.0 13.00 99 116 114 121 10x8 .41 .39 6.5 7.50 11.0 13.00 116 128 138 135 10 .41 .41 7.5 7.50 11.0 ... 132 144 ... 156 12x3 .43 .34 4.0 8.75 12.0 ... 99 12x4 .43 .35 4.5 8.75 12.0 ... 108 118 ... 119 12x6 .43 .37 5.5 8.75 12.0 14.25 119 133 132 138 12x8 .43 .39 6.5 8.75 12.0 14.25 126 146 149 149 12x10 .43 .41 7.5 8.75 12.0 ... 159 174 ... 187 12 .43 .43 8.75 8.75 12.0 ... 171 198 ... 202 14x6 .51 .44 6.5 10.50 14.0 16.00 183 205 211 210 148 .51 .45 7.5 10.50 14.0 ... 211 ... ... 231 14x10 .51 .46 8.5 10.50 14.0 ... 229 244 ... 255 14x12 .51 .47 9.5 10.50 14.0 ... 245 284 ... 269 14 .51 .51 10.5 10.50 14.0 ... 281 291 ... 299 16x6 .52 .45 6.5 11.50 15.0 17.00 222 230 243 250 16x8 .52 .46 7.5 11.50 15.0 ... 245 248 ... 264 16x10 .52 .47 8.5 11.50 15.0 ... 265 287 ... 286 16x12 .52 .48 9.5 11.50 15.0 ... 277 312 ... 312 16x14 .52 .51 10.5 11.50 15.0 ... 317 348 16 .52 .52 11.5 11.50 15.0 ... 337 324 ... 457 30 .66 .66 22.0 22.00 ... ... ... ... ... 1840 36 .74 .74 26.0 26.0 ... ... ... ... ... 2655 t Weights include swivel gland Tyler Utilities Division • 11910 C 492 . Tyler, Texas 75706 . (800) 527-8478 4 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 02/01/08 18x6 .59 .44 6.5 14.5 15.5 18.0 275 261 279 18x8 .59 .45 7.5 14.5 14.5 ... 280 351 18x10 .59 .47 8.5 12.5 ... ... 286 18x12 .59 .49 9.5 12.5 ... ... 372 18x14 .59 .56 10.5 12.5 ... ... 415 18x16 .59 .57 11.5 12.5 ... ... 445 18 .59 .59 13.0 12.5 ... ... 490 20x6 .60 .44 7.0 16.0 17.0 19.5 335 362 358 20x8 .60 .45 8.0 14.0 ... ... 390 20x10 .60 .47 9.0 14.0 ... ... 417 20x12 .60 .49 10.0 14.0 ... ... 460 20x14 .60 .56 11.0 14.0 ... ... 475 20x16 .60 .57 12.0 14.0 ... ... 530 20x18 .60 .59 13.0 14.0 ... ... 560 20 .60 .60 14.0 14.0 ... ... 605 24x6 .62 .44 7.0 18.0 19.0 21.5 465 451 457 248 .62 .45 8.0 16.0 ... ... 475 24x10 .62 .47 9.0 16.0 ... ... 516 24x12 .62 .49 10.0 18.0 ... ... 549 580 24x14 .62 .56 11.0 16.0 ... ... 585 24x16 .62 .57 12.0 19.5 ... ... 625 744 24x18 .62 .59 13.0 16.0 ... ... 675 24x20 .62 .60 15.0 17.0 ... ... 740 24 .62 .62 17.0 17.0 ... ... 844 30x6 .66 .36 7.00 20.0 ... ... 700 30x8 .66 .38 8.50 20.0 ... ... 739 30x12 .66 .42 10.0 20.0 ... ... 739 30x16 .66 .50 12.5 20.0 ... ... 959 30x20 .66 .57 15.0 20.0 ... ... 995 30x24 .66 .61 16.0 20.0 ... ... 1160 30 .66 .66 20.0 20.0 ... ... 1323 36x16 .74 .50 12.5 23.5 ... ... 1350 36x24 .74 .61 16.0 23.5 ... ... 1498 36x30 .74 .66 20.0 23.5 ... ... 1555 36 .74 .74 23.5 23.5 ... ... 1900 42 .82 .82 30.0 30.0 ... ... 3175 f Weights include swivel gland. LAYING LENGTH SIZE Swivel x Solid Adapter with Swivel Gland Size by Wall Laying Length Thickness Weight 6x13 .37 52 6x18 .37 65 6x24 .37 69 8x12 .39 52 E Swivel x Swivel Adapter Size by Wall Laying Length Thickness Weight 6x12 .37 28 6x18 .37 49 6x24 .37 52 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION® Sizes 30 thru 12" UL Listed For Fire Main Equipment TEES (Continued) MJ GLANDS -n-n- - - - - MI Tee MJ x FE Tee MJ x Swivel Tee Dimensions Weights Size 1 1' H ji J2 J3 Mi MJxFE fMlxS LL Glands Size Size Weight Size Weight 3 3 12 10 4 4 14 17 6 5 16 21 8 6 18 22 10 9 20 32 24 37 Tyler Utilities Division • 11910 CR 492 Tyler, Texas 75706 . (800) 527-8478 02/01/08 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 5 M.jxMi MJ$EBxPE MiLEBxPE PExPE 18 28 28 36 39 53 59 54 67 64 57 63 104 104 100 100 132 136 128 120 140 201 196 175 180 194 225 214 208 225 233 320 314 325 325 315 475 495 525 478 770 1185 1505 17 25 26 34 38 46 48 52 61 58 62 61 107 107 102 101 131 128 124 123 139 180 180 170 181 180 210 208 198 215 220 302 325 319 310 305 565 590 560 495 890 874 746 725 17 27 27 36 39 51 52 52 68 66 65 65 112 108 100 100 141 136 128 119 138 195 185 190 200 190 210 210 205 222 300 322 340 18 20 26 33 30 49 47 60 54 60 57 100 128 136 123 113 133 02/01/08 MECHANICAL JOINT C153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment TYLER UNION® WYES/LATERAL Dimensions Mi SEB LEB PE Weights Size T T' L L L L Ml SEB LEB PE 4x3 .35 .34 3.0 8.5 8.5 14.0 *Wyes 6x3 .37 .34 5.0 10.5 10.5 16.0 6x4 .37 .35 4.0 9.5 9.5 15.0 Size A Dimensions Y 1 1' Weights 8x4 .39 .35 5.0 10.5 10.5 16.0 8x6 .39 .37 4.0 9.5 9.5 15.0 3 2.5 7.5 .34 .34 36 10x4 .41 .35 7.0 12.5 12.5 18.0 4x3 2.0 8.5 .35 .34 39 10x6 .41 .37 5.0 10.5 10.5 16.0 4 2.5 8.5 .35 .35 45 10x8 .41 .39 4.0 9.5 9.5 15.0 6x4 1.5 11.0 .37 .35 67 12x4 .43 .35 9.0 14.5 14.5 20.0 6 3.0 13.0 .37 .37 85 12x6 .43 .37 7.0 12.5 12.5 18.0 8x4 0.5 13.0 .39 .35 86 12x8 .43 .39 5.0 10.5 10.5 16.0 8x6 2.0 14.5 .39 .37 109 12x10 .43 .41 4.0 9.5 9.5 15.0 8 3.5 16.0 .39 .39 117 14x6 .51 .44 9.0 17.0 14.5 22.5 10x4 0.0 15.0 .41 .35 112 14x8 .51 .45 7.0 15.0 12.5 20.5 10x6 1.0 16.0 .41 .37 129 1410 .51 .46 5.0 13.0 10.5 18.5 10x8 2.5 17.0 .41 .39 162 1412 .51 .47 4.0 12.0 9.5 17.5 10 3.5 19.0 .41 .41 199 16x6 .52 .45 11.0 19.0 16.5 24.5 12x4 0.0 16.5 .43 .35 141 16x8 .52 .46 9.0 17.0 14.5 22.5 12x6 1.5 18.5 .43 .37 170 16x10 .52 .47 7.0 15.0 12.5 20.5 12x8 1.5 18.5 .43 .39 177 16x12 .52 .48 5.0 13.0 10.5 18.5 12x10 3.0 20.0 .43 .41 216 16x14 .52 .51 4.0 12.0 12.0 20.0 18x8 .59 .45 14.0 22.0 19.5 27.5 12 4.5 22.5 .43 .43 269 18x10 .59 .47 12.0 20.0 17.5 25.5 t14 6.0 25.0 .51 .51 476 18x12 .59 .49 10.0 18.0 15.5 23.5 16x6 0.0 21.0 .52 .45 300 18x14 .59 .56 8.0 16.0 16.0 24.0 16x8 0.5 22.5 .52 .46 349 18x16 .59 .57 7.0 15.0 15.0 23.0 t16x12 3.5 25.0 .52 .48 471 20x10 .60 .47 14.0 22.0 19.4 27.5 t16 6.5 28.0 .52 .52 635 20x12 .60 .49 12.0 20.0 17.5 25.5 * Not included inAWWAC153. 20x14 .60 .56 10.0 18.0 17.8 26.0 f Rated af250psi. 20x16 .60 .57 8.0 16.0 15.8 24.0 20x18 .60 .59 7.0 15.0 15.0 23.0 MJ x FE Flange Dimensions are on inside front cover. 24x12 .62 .49 16.0 24.0 21.4 29.5 24x14 .62 .56 14.0 22.0 21.8 30.0 24x16 .62 .57 12.0 20.0 19.8 28.0 24x1 8 .62 .59 10.0 18.0 18.0 26.0 24x20 .62 .60 8.0 16.0 16.0 24.0 30x16 .66 .50 30.0 39.0 30x18 .66 .54 28.0 37.0 _______ 30x20 .66 .57 24.0 33.0 MJxPExMJTee 30x24 .66 .61 10.0 24.5 Dimensions 36x16 .74 .50 ... Size T V H Ji Z Weights 36,20 .74 .57 ... 45.0 6 .37 .37 5.0 5.0 11.5 57 36x24 .74 .61 19.0 33.0 8x6 .39 .37 5.5 6.5 11.5 79 36x30 .74 .66 ... 24.5 8 .39 .39 6.5 6.5 12.5 83 4200 .82 .66 20.0 10 .41 .41 7.5 7.5 13.0 133 48x30 .90 .66 40.0 Tyler Utilities Division • 11910 C 492 Tyler, Texas 75706 (800) 527-8478 6 Union Foundry Company• Box 309 • Anniston, Alabama 36202 . (800) 226-7601 SOLID & TAPPED PLUGS & CAPS 3-12' 14-24" Mi Plug Dimensions Size 1 3 .46 4 .46 6 .46 8 .46 10 .56 12 .56 14 .62 16 .62 18 .65 20 .66 24 .68 30 .66 36 .74 DII 3-1 2" 14-24" Mi Cop tax. Weights rap Plugs Caps 2 9 8 2 9 10 2 18 18 2 25 26 2 36 32 2 47 46 2 76 85 2 98 94 2 138 121 2 158 149 2 223 210 2 355 345 2 688 626 TAPPED TEE Mi Tapped Tee (2" Tap) SOLID SLEEVES I Lz Size Dimensions T L 3 .34 6 4 .35 6 6 .37 6 8 .39 6 10 .41 6 12 .43 6 16 .52 6 02/01/08 MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS TYLER UNION® Sizes 3" thru 12" UL Listed For Fire Main Equipment Short Long Dimensions Weights Size I L1 L2 Short Long 3 .34 7.5 12 13 22 4 .35 7.5 12 19 25 6 .37 7.5 12 28 39 8 .39 7.5 12 38 55 10 .41 7.5 12 48 68 12 .43 7.5 12 62 81 14 .56 9.5 15 116 146 16 .57 9.5 15 138 174 18 .68 9.5 15 160 230 20 .69 9.5 15 212 269 24 .75 9.5 15 272 380 30 .66 15.0 15 500 30 .66 ... 24 ... 640 36 .74 15.0 15 725 36 .74 ... 24 ... 925 42 .82 ... 24 ... 1146 48 .90 ... 24 ... 1455 ADAPTERS Lz MJxFE FExPE Dimensions Weights Size T L1 L2 MJxFE FEXPE 3 .34 6 12 Max. Tap Weights 4 .35 6 12 2 19 6 .37 6 12 2 23 8 .39 6 12 2 35 10 .41 6 12 2 54 12 .43 6 12 2 68 14 .51 6 12 2 88 16 .52 6 12 2 164 20 .60 6 30 .66 7 36 .74 8 Tyler Utilities Division • 11910 CR 492 . Tyler, Texas 75706 (800) 527-8478 Union Foundry Company Box 309 . Anniston, Alabama 36202 . (800) 226-7601 18 26 36 50 60 88 127 155 275 470 750 23 35 50 69 88 149 7 TYLER UNION® DUAL PURPOSE CUTTING-IN SLEEVE MECHANICAL JOINT Cl 53 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12 UL Listed For Fire Main Equipment MI x FE Cutting-In Sleeve with Dual Purpose Accessories Dimensions Shipping Wt. Size For Pipe Size L L1 I Assembled 4 4.80-5.00 O.D. 10 9.5 .35 33 6 6.90-7.100.D. 10 9.5 .37 50 8 9.05-9.30 O.D. 10 9.5 .39 67 10 11.10-11.400.D. 10 9.5 .41 122 12 13.20-13.500.D. 10 9.5 .43 157 Flanged ends are faced and drilled per ANSI/AWWA Cl10/A21.1 0. Mechanical joint ends are designed to receive both stan- dard and oversize gray or ductile iron pipe as shown above. TYPICAL CUTTING-IN SLEEVE INSTALLATIONS L1).NtiEi VALVE INSTALLATIONS *RETAINER GLAND ASSEMBLY Pipe Wall Thickness: Sizes 3-12" are recommended for ductile iron pipe class 50 thru 56. Sizes 14" thru 24" are recommended for ductile iron pipe class 53 thru 56. DUCTILE IRON RETAINER GLANDS Mechanical Joint Retainer Glands are designed to provide a method for restrain- ing mechanical joint pipe and fittings and other standardized mechanical joints against possible joint separation, rupture or blow-out caused by internal water pres- sure. The set screws are square-headed with Type C knurled cup points, and are shipped already assembled in the Glands. They are manufactured of 4140 grade alloy steel, and are heat treated to a Rock- wall "C" 45/53 case hardness. Tee-head bolts and gaskets are not included, but may be ordered separately. Recommend- ed torque for set screws is 75 foot pounds, and set screws on opposite sides of the glands should be tightened alternately. Tee-head bolt hole size and spac- ing are equal to Mi Glands as shown in AWWA C-i 11. Standard mechanical Joint gaskets as shown in C-i ii should be used. I.. r.,sr,srs_rr•r5sr_rnrrsgr,rsrsrsrrA A See Installations Instructions........................................................Page 50 Pressure Gland Pipe O.D. D.I. Pipe No of Size of Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces. 3 350 7.69 3.96 50-56 4 5/8x2 5 7 4 350 9.12 4.80 50-56 4 5/sx2 6 13 6 350 11.12 6.90 50-56 6 %x2 11 20 8 250 13.37 9.05 50-56 9 %x2 13 25 10 250 15.62 11.10 50-56 12 5/8x2 18 33 12 150 17.88 13.20 50-56 16 5/8x2 23 38 14 250 20.25 15.30 53-56 20 5/sx2½ 44 55 16 200 22.50 17.40 53-56 24 %x21/2 51 64 18 200 24.75 19.50 53-56 24 5/8x2½ 62 72 20 200 27.00 21.60 53-56 28 5/8x3 73 91 24 150 31.50 25.80 53-56 32 5/8x3 93 118 * Not included in AWWA Cli 0 Tyler Utilities Division • 11910 C 492 . Tyler, Texas 75706 (800) 527-8478 8 Union Foundry Company• Box 309 . Anniston, Alabama 36202 • (800) 226-7601 02/01/08 10 900 Bend Mi x PE (1/4) 45° Bend Ml x PE (1/8) L_ _- 22'/2° Bend Mix PE (1/16) 1 P14° Bend Mix PE (1/32) Y -I 45° Bend Mi x Flange 22h/2 Bend Mix Flange 111/40 Bend Mi x Flange (1/8) (1/16) (1/32) Tyler/Union MECHANICAL JOINT C 153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment BENDS Dimensions Dimensions Dimensions Dimensions Size I A Y R Weight A Y R Weight A Y R Weight A Y R Weight 3 .34 4.5 10.0 4.0 18 2.0 7.5 3.62 17 1.50 7.00 4.98 19 1.25 6.75 7.62 15 4 .35 5.0 10.5 4.5 26 2.5 8.0 4.81 22 1.82 7.32 6.66 20 1.55 7.05 10.70 20 6 .37 6.5 12.0 6.0 45 3.5 9.0 7.25 38 2.58 8.08 13.50 33 1.80 7.30 13.26 32 8 .39 7.5 13.0 7.0 64 4.0 9.5 8.44 55 2.84 8.34 11.80 51 2.05 7.55 15.80 44 10 .41 9.5 15.0 9.0 108 5.0 10.5 10.88 78 3.35 8.85 14.35 66 2.31 7.81 18.36 60 12 .43 10.5 16.0 10.0 114 6.0 11.5 13.25 104 3.86 9.36 16.90 89 2.56 8.06 20.90 79 14 .51 12.0 20.0 11.5 219 5.5 13.5 12.06 165 3.93 11.93 17.25 152 2.59 10.59 21.25 137 16 .52 13.0 21.0 12.5 254 6.0 14.0 13.25 206 3.98 11.98 17.50 181 2.62 10.62 21.50 161 24 .62 17.0 25.0 15.58 710 7.5 16.2 14.69 460 9.00 17.00 37.69 455 9.00 17.00 76.12 475 30 * (Available Soon see List Prices) * (Available Soon see List Prices) * (Available Soon see List Prices) * (Available Soon see List Prices) 90° Bend Mi x Flange (1/4) Dimensions Dimensions Dimensions Dimensions Size T A R F Weight A R F Weight A R F Weight A R F Weight 3 .34 4.5 4.0 5.5 21 ... ... .. .. ... ... .. .. ... 4 .35 5.0 4.5 6.5 28 2.50 3.56 4.0 34 1.75 3.81 4.0 34 1.50 5.12 4.0 19 6 .37 6.5 6.0 8.0 45 3.25 5.49 5.0 57 2.25 6.35 5.0 57 1.50 5.12 5.0 30 8 .39 7.5 7.0 9.0 73 4.25 7.93 5.5 83 2.50 7.62 5.5 83 1.75 7.70 5.5 50 10 .41 9.5 9.0 11.0 113 5.00 9.76 6.5 122 3.00 10.16 6.5 122 2.00 10.25 6.5 75 12 .43 10.5 10.0 12.0 141 6.00 12.19 7.5 159 3.50 12.70 7.5 159 2.25 12.82 7.5 88 14 .51 12.0 11.5 14.0 217 5.5010.85 8.5 207 16 .52 13.0 12.5 15.0 280 6.00 12.02 9.5 290 B - 900 Swivel x Swivel Hydrant Ell Dimensions Size I A B C D E F R *Weight 6 .37 10.5 15.5 6.90 11.2 6.81 7.98 6.0 74 A * Weight includes two swivel glands. FD Tyler Pipe/Utilities Division • P.O. Box 2027 'Tyler; Texas 75710 • (903) 882-5511 Union Foundry Company• P.O. Box 309 • Anniston, Alabama 36202 9 (256) 236-7601 4-4-2003 Tyler/Uni*on TEES MECHANICAL JOINT C 153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment CROSS MJ Tee Mi x FE Tee Ml x Swivel Tee Cross Dimensions Weights Size T 1' H I' P J3 MJ MJxFE MJxSt Cross 3 .34 .34 3.5 3.50 5.5 ... 26 29 ... 31 4x3 .35 .34 3.5 4.00 6.5 ... 35 34 ... 39 4 .35 .35 4.0 4.00 6.5 ... 36 39 ... 45 6x3 .37 .34 3.5 5.00 8.0 ... 51 54 6x4 .37 .35 4.0 5.00 8.0 ... 52 57 ... 62 6 .37 .37 5.0 5.00 8.0 10.50 66 68 77 79 8x3 .39 .34 4.0 6.50 9.0 ... 56 8x4 .39 .35 4.5 6.50 9.0 ... 72 82 ... 84 8x6 .39 .37 5.5 6.50 9.0 11.50 79 81 105 98 8 .39 .39 6.5 6.50 9.0 11.50 90 101 116 112 10x3 .41 .34 4.0 7.50 11.0 ... 80 10x4 .41 .35 4.5 7.50 11.0 ... 82 92 ... 98 10x6 .41 .37 5.5 7.50 11.0 13.00 99 116 114 121 10x8 .41 .39 6.5 7.50 11.0 13.00 116 128 138 135 10 .41 .41 7.5 7.50 11.0 ... 132 144 ... 156 12x3 .43 .34 4.0 8.75 12.0 ... 99 12x4 .43 .35 4.5 8.75 12.0 ... 108 118 ... 119 12x6 .43 .37 5.5 8.75 12.0 14.25 119 133 132 138 12x8 .43 .39 6.5 8.75 12.0 14.25 126 146 149 149 12x10 .43 .41 7.5 8.75 12.0 ... 159 174 ... 187 12 .43 .43 8.75 8.75 12.0 ... 171 198 ... 202 14x6 .51 .44 6.5 10.50 14.0 16.00 183 205 211 210 14x8 .51 .45 7.5 10.50 14.0 ... 211 ... ... 231 14x10 .51 .46 8.5 10.50 14.0 ... 229 244 ... 255 14x12 .51 .47 9.5 10.50 14.0 ... 245 284 ... 269 14 .51. .51 10.5 10.50 14.0 ... 281 291 ... 299 16x6 .52 .45 6.5 11.50 15.0 17.00 222 230 243 250 16x8 .52 .46 7.5 11.50 15.0 ... 245 248 ... 264 16x10 .52 .47 8.5 11.50 15.0 ... 265 287 ... 286 16x12 .52 .48 9.5 11.50 15.0 ... 277 312 ... 312 16x14 .52 .51 10.5 11.50 15.0 ... 317 348 16 .52 .52 11.5 11.50 15.0 ... 337 324 ... 457 t Weights include swivel gland Tyler Pipe/Utilities Division • P.O. Box 2027. Tyler, Texas 75710 • (903) 882-5511 44-2003 .. Union Foundry Company • P.O. Box 309 9 Anniston, Alabama 36202' (256) 236-7601 - 3 Mi GLANDS Glands Size Weight Size Weight 3 3 12 10 4 4 14 17 6 5 16 21 8 6 18 22 10 9 20 32 24 37 TEES (Continued) Ml x Swivel Tee Ml x FE Tee Mi Tee 18x6 .59 .44 6.5 12.5 15.5 18.0 18x8 .59 .45 7.5 12.5 18x10 .59 .47 8.5 12.5 18x12 .59 .49 9.5 12.5 18x14 .59 .56 10.5 12.5 18x16 .59 .57 11.5 12.5 18 .59 .59 12.5 12.5 20x6 .60 .44 7.0 14.0 17.0 19.5 20x8 .60 .45 8.0 14.0 20x10 .60 .47 9.0 14.0 20x12 .60 .49 10.0 14.0 20x14 .60 .56 11.0 14.0 20x16 .60 .57 12.0 14.0 20x18 .60 .59 13.0 14.0 20 .60 .60 14.0 14.0 24x6 .62 .44 7.0 16.0 19.0 21.5 24x8 .62 .45 8.0 16.0 24x10 .62 .47 9.0 16.0 24x12 .62 .49 10.0 16.0 24x14 .62 .56 11.0 16.0 24x16 .62 .57 12.0 16.0 24x18 .62 .59 13.0 16.0 24x20 .62 .60 15.0 17.0 24 .62 .62 17.0 17.0 30x6 * (Available Soon see List Prices) 30x8 * (Available Soon see List Prices) 30x1 2 * (Available Soon see List Prices) 30x16 * (Available Soon see List Prices) 30x20 * (Available Soon see list Prices) 30x24 * (Available Soon see List Prices) 30 * (Available Soon see List Prices) 36x16 * (Available Soon see List Prices) 36x24 * (Available Soon see List Prices) 3600 * (Available Soon see List Prices) 36 * (Available Soon see List Prices) 275 261 279 280 351 286 372 415 445 490 335 362 358 390 417 460 475 530 560 605 465 451 457 475 516 549 580 585 625 744 675 740 844 Size by Wall Laying Length Thickness Weight 6x13 .37 52 6x18 .37 65 6x24 .37 69 8x12 .39 52 •• Size by Wall Laying Length Thickness Weight 6x12 .37 28 6x18 .37 49 6x24 .37 52 01 Tyler/Un*ion MECHANICAL JOINT C 153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment Dimensions Weights Size T T' H .1' J2 J3 MJ MJxFE tMJxS t Weights include swivel gland. Tyler Pipe/Utilities Division • P.O. Box 2027. Tyler, Texas 75710 • (903) 882-5511 4 Union Foundry Company • P.O. Box 309 9 Anniston, Alabama 36202 • (256) 236-7601 4-4-2003 Tyler/Un*ion DUCTILE IRON Cl 10 FULL BODY MECHANICAL JOINT FITTINGS *RETAINER GLAND ASSEMBLY I.. flfltflh,4'flfl,,Ftflflfl See Installations Instructions Page 49 Pressure Gland Pipe O.D. D.I. Pipe No of Size of Rating, O.D. O.D. Wall Set Set Gland Weight Size psi B A Class Screws Screws Weight w/Acces. 3 350 7.69 3.96 50-56 4 5 /8x2 4 8 4 350 9.12 4.80 50-56 4 5/8x2 5 11 6 350 11.12 6.90 50-56 6 /8x2 9 16 8 250 13.37 9.05 50-56 9 5/84 13 21 10 250 15.62 11.10 50-56 12 /8x2 17 26 12 150 17.88 13.20 50-56 16 5/8x2 20 28 14 250 20.25 15.30 53-56 20 5/8x21/2 44 55 16 200 22.50 17.40 53-56 24 5/8x21/2 54 64 18 200 24.75 19.50 53-56 24 5/8x21 /2 62 72 20 200 27.00 21.60 53-56 28 5/8x3 76 91 24 150 31.50 25.80 53-56 32 /x3 103 118 * Not included in AWWA Cl 10 TEES Mi x Mi x Swivel Dimensions Size X Y Weight 6 8.0 10.5 150 8x6 9.0 11.5 199 Pipe Wall Thickness: Sizes 3-1 2" are recommended for ductile iron pipe class 50 thru 56. Sizes 14" thru 24" are recommended for ductile iron pipe class 53 thru 56. DUCTILE IRON RETAINER GLANDS Mechanical Joint Retainer Glands are designed to provide a method for restrain- ing mechanical joint pipe and fittings and other standardized mechanical joints against possible joint separation, rupture or blow-out caused by internal water pressure. The set screws are square-headed with Type C knurled cup points, and are shipped already assembled in the Glands. They are manufactured of 4140 grade alloy steel, and are heat treated to a Rockwall "C" 45/ 53 case hardness. Tee-head bolts and gaskets are not included, but may be ordered separately. Recommended torque for set screws is 75 foot pounds, and set screws on opposite sides of the glands should be tightened alternately. Tee-head bolt hole size and spacing are equal to Mi Glands as shown in AWWA C- 111. Standard mechanical Joint gaskets as shown in C-i 11 should be used. Mi GLAND Size Gland Weight Wt. Pack Gland Only 2 5 3 3 7 4 4 10 6 6 16 10 8 25 16 10 30 19 12 40 26 14 45 34 8 9.0 11.5 210 16 55 54 10x6 11.0 13.5 267 18 65 52 12x6 12.0 14.5 346 20 85 73 16x6 15.0 17.5 619 24 105 91 16x8 15.0 17.5 649 30 220 90 30x6 18.0 24.5 2070 36 301 127 All weights shown include the Swivel Gland ANSI/AWWA C1 10/A21.10, ANSI/AWWA C1 1/A21.11 Tyler Pipe/Utilities Division • P.O. Box 2027• Tyler, Texas 75710 • (903) 882-5511 4-4-2003 Union Foundry Company P.O. Box 309 9 Anniston, Alabama 36202 • (256) 236-7601 IM Tyler/Un*ion ADAPTERS DUCTILE IRON Cl 10 FULL BODY MECHANICAL JOINT ELLS, ADAPTERS AND GLANDS For Valve and Hydrant Connections Swivel x Solid Adapter Size by Wall Laying Length Thickness Weight* 4x13 .52 52 6x12 .55 84 6x18 .55 91 6x24 .55 105 6x36 .55 156 8x13 .60 126 12x13 .75 186 Weights with Gland. ELLS *900 Swivel x Swivel Ell (Not Included In AWWA C 110) Wall Dimensions Size Thickness A B C D E F R *Weight 6 .55 10.5 15.5 7.10 11.12 6.90 8.02 6.0 106 8 .60 11.5 16.5 9.20 13.37 9.05 10.17 7.0 156 * With 2 Swivel Glands SWIVEL GLAND ASSEMBLY Used with swivel fittings, the TYLER Swivel Gland, with its rotating feature, permits the installer to meet any grade requirements regardless of bolt-hole alignment. In addition, the system permits stiff connections without braces, blocking or strapping. Swivel Glands** Size Weight 4 12 6 17 8 23 12 30 ** Not included in AWWA Cl10. NOTE: When ordering glands separately, Specify TYLER UPC Code Number, Description, and Size of fitting to be loined. ANSI/AWWA Cl 1O/A21.10, ANSI/AWWA Cli l/A2l.11 Tyler Pipe/Utilities Division • P.O. Box 2027'* Tyler, Texas 75710 • (903) 882-5511 20 Union Foundry Company • P.O. Box 309 9 Anniston, Alabama 36202 • (256) 236-7601 4-4-2003 Tyler/.Un*ion TEES UNION-TITE DUCTILE IRON C153 COMPACT FITTINGS UT x UT Tees UT x Flange Tees UT x Swivel Tees Size I Ti Dimensions H ii 12 J3 UT x UT Weights UT xFlange UT x Swivel 4 .35 .35 4.5 4.5 6.5 ... 44 45 6x4 .37 .35 5.0 6.0 8.0 ... 68 56 6 .37 .37 6.0 6.0 8.0 9.5 69 71 65 8x4 .39 .35 5.0 7.0 9.0 ... 73 89 8x6 .39 .37 6.0 7.0 9.0 10.5 96 101 100 8 .39 .39 7.0 7.0 9.0 10.5 116 117 110 10x4 .41 .35 6.0 9.0 11.0 ... 102 115 10x6 .41 .37 7.0 9.0 11.0 12.5 113 128 130 10x8 .41 .39 8.0 9.0 11.0 12.5 145 145 156 10 .41 .41 9.0 9.0 11.0 ... 155 158 12x4 .43 .35 6.0 10.0 12.0 ... 119 138 12x6 .43 .37 7.0 10.0 12.0 13.5 141 148 162 12x8 .43 .39 8.0 10.0 12.0 13.5 177 170 158 12x10 .43 .41 9.0 10.0 12.0 ... 160 162 12 .43 .43 10.0 10.0 12.0 ... 217 183 14x6 .51 .44 6.5 10.5 12.5 14.0 176 212 202 14x10 .51 .46 8.5 10.5 12.5 ... 195 246 14x12 .51 .47 9.5 10.5 12.5 ... 196 296 14 .51 .51 10.5 10.5 14.0 ... 209 321 16x6 .52 .45 6.5 11.5 13.5 15.0 266 160 229 16x8 .52 .46 7.5 11.5 13.5 15.0 292 270 292 16x10 .52 .47 8.5 11.5 13.5 ... 232 330 16x12 .52 .48 9.5 11.5 13.5 ... 239 321 16x14 .52 .51 10.5 11.5 15.0 ... 349 342 16 .52 .52 11.5 11.5 15.0 ... 261 355 18x6 .59 .44 6.5 12.5 14.5 16.13 348 301 348 18x8 .59 .45 7.5 12.5 14.5 16.13 325 319 324 18x10 .59 .47 8.5 12.5 14.5 ... 344 337 18x14 .59 .56 10.5 12.5 16.0 ... 342 393 18x16 .59 .57 11.5 12.5 16.0 ... 362 420 20x6 .60 .44 7.0 14.0 16.0 17.5 355 341 400 20x10 .60 .47 9.0 14.0 16.0 ... 369 420 20x14 .60 .56 11.0 14.0 17.5 ... 484 474 20x16 .60 .57 12.0 14.0 17.5. ... 610 498 20x18 .60 .59 13.0 14.0 .17.5 ... 539 24x6 .62 .44 7.0 16.0 18.0 19.5 385 512 525 24x10 .62 .47 9.0 16.0 18.0 ... 478 468 24x12 .62 .49 10.0 16.0 18.0 ... 663 503 2414 .62 .56 11.0 16.0 19.5 .., 542 531 24x16 .62 .57 12.0 16.0 19.5 ... 566 555 24x18 .62 .59 13.0 16.0 ... ... 593 24x20 .62 .60 15.0 17.0 ... ... 628 24 .62 .62 17.0 17.0 ... ... 884 Tyler Pipe/Utilities Division • P.O. Box 2027 Tyler, Texas 75710 • (903) 882-5511 24 Union Foundry Company • P.O. Box 309 9 Anniston, Alabama 36202 • (256) 236-7601 4-4-2003