Loading...
HomeMy WebLinkAbout2511 GATEWAY RD; ; FPC2021-0154; PermitCity of PERMIT REPORT Carlsbad Print Date: 09/16/2021 Permit No: FPC2021-0154 Job Address: 2511 GATEWAY RD, CARLSBAD, CA 92009-1742 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2132601100 Track #: Applied: 08/17/2021 Valuation: $28,371.10 Lot #: Issued: 09/07/2021 Occupancy Group: Project #: Finaled Close Out: 09/16/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check#: Final Inspection: Project Title: Description: VIASAT E4 GEM LAB -SPRINKLER TI (12 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC EDUARDO MARTINEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 760-602-4665 1760-602-8561 f I www.carlsbadca.gov A ITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 21485 ViaSat E4 GEM LBS T.I. 2511 GATEWAY ROAD CARLSBAD, CA 92009 Is WARNING: Cancer and Reproductive Harm- www.P65Wamings,ca,gov Page 1 of 6 tII II(IIS1G® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1. DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small ther- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 LPCB Approved: Certificate 096e/06 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1 003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) .cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 'C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-I Escutcheon.) Page 2 of 6 MICROFAST® QUICK NIKJNG*l:II[.nuIyIy RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 197 1) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap = 019 21475 .1: Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F_033314 19.02.21 Rev 19.1 Page 30f6 i7 MICROFAST®QUICK kc l RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient u Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 1/2" ratchet is require . (not available from Viking) L Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F033314 19.02.21 Rev 19.1 Page 4 of 6 V\ fl[[1 /7HE R: MICROFAST® QUICK fl I:IIE.cu.LIv1, RESPONSE PENDENT i H SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Tempraure KEY The Viking Microfase Quick Response Finsh Pendent Sprinkler VK302 AIX - Escutcheon (if appticase) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals3 Part SIN Style K.Factor Length (Refer also to Design Criteria.) Number' NPT BSP U.S. metric2 Inches mm cULus4 VdS LPCB (E 1 8 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y Dl -- 19780 VK302 Pendent 1/2" -__F5 6 80.6 2-1/4 58 -- -- -- -- -- D3 21354 VK302 Pendent -- 15 mm 1 56 80.6 2-1/4 58 -- -- -- -- -- D3 06662B VK302 Pendent 1/2" 15mm 5.6 80.6 2-1/4 58 jA1Z,B1YD2,C2Xj -- -- -- -- - 18021 VK302 Pendent 1/2" 15mm 56 80.6 1 2-1/4 58 A1X,B1Y Al A1X,B1Y D1X,C1Y7 Dl -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 °F (93 °C), 286 °F (141 °C) Polyester56, Black Polyes- Viking Micromatice Model E-1 Recessed Escutcheon B - 135 °F (57 °C), 155 °F (68 °C), 175 °F ter56 Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic (79 °C), and 200 °F (93 °C) 2 - ENT5 Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 °F (68 °C), 175 °F (79 °C), and 3 - Chrome Z - Standard surface-mounted escutcheon 200 °F (93 °C) D -155 °F (68 °C), 175 °F (79 "C), 200°F (93 °C), 286 °F (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 fl71L\ '2 MICROFAST®QUICK lII[U'YM RESPONSE PENDENT SPRINKLER VK302 (K56) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) - - Temperature KEY The Viking Microfaste Quick Response Fsh Pendent Sprinkler VK302 A 4— Escutcheon (if apphcable) Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric' Inches mm Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 wr M . 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons A - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F X - Standard surface-mounted escutcheon or the (93 °C), 286 °F (141 °C) Approved Finishes Viking Micromatic® Model E-1 Recessed B -135°F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1- Brass, Chrome, White Polyester4, Escutcheon 200 °F (93 °C) and Black Polyester' Y - Standard surface-mounted escutcheon or recessed C - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), 286 2 - ENT5 with the Viking Micromatic® Model E-1 or E-2 °F (141 °C) Recessed Escutcheon D - 155°F (68 °C), 175 °F (79 °C), 200 °F (93 °C) Z - Standard surface-mounted escutcheon Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) The Viking Microfast® Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 60f6 \ flt1 R MICROFAST® QUICK l.I:II[.q.u'y.Ii RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT t (57 mm) Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon 'rI (54 mm) C. Ii + 1-3/4" (4m) 0 I.2-1/8" (54 mm) :, 1-1/8" I (29 mm) (51 mm) Max + Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum 1-1/8" (29 mm) Mm. Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 1 of 4 flflfl /711f; fl ® MICROFAST® QUICK \\ '1I l:IIEu.y RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 ¶168 °C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 .17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 4 [.çTh A: MICROFAST® QUICK A02 1 Q RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1 : AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135°F(57°C) 100F(38°C) Orange Ordinary 155F(68°C) 100F(38°C) Red Intermediate 175 °F (79 °C) 150 ¶ (65 °C) Yellow Intermediate 200 °F (93 °C) 150 ¶ (65 °C) Green High 286 F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 17.10.05 Rev 17.1 Page 3 of 4 \ fl[ilfl/7HE\ ['2 MICROFAST® QUICK l:lI[.1u.YM RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) TeIvperaL.'e KEY Microfast Quick Response ++ Firsh A1X4 Escutcheon .fappicabe) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN Number' NPT BSP U.S. metric2 Inches mm cULus VdS LPCB NYC' CE 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A1,132 -- -- See footnote 7. -- 06661B VK300 1/2" 15 mm 1 5.6 80.6 1 2-3/16 56 1 Al, B2 I -- -- See footnote 7.1 -- Approved Temperature Ratings Approved Finishes A- 135 OF (57 °C), 155 OF (68 °C), 175 OF (79 °C), 200°F (93 °C), and 286 °F (141°C) 1 - Brass, Chrome, White Polyester5'6, and Black Polyester56 B - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), and 286 OF (141°C) 2 - ENT Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 17.10.05 Rev 17.1 Page 4 of 4 MICROFAST@ QUICK TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY Microfast° Quick Response Finish FA'I'X - Escutcheon (:1 applicable) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT F BSP U.S. metric2 Inches mm Number' (Refer also to Design Criteria below.) 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A1,132 06661B VK300 1 1/2" 15 mm 1 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 Brass Chrome, White Polyester5, and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) Polyesierl 2 -ENT 6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 6 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM ApDroval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) JRDL 11 __ FFw TID Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVED 06 4. ONFSA I'IFPA' 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft -. 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3500 3.260 354 4341bs/ft 7957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.661bs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.581bs1ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *Only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullmoosetube.com (iAs ~_Do Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com ®r. - 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masurt OH BU" MOOSE TUBE COMPANV 63017 Dull Moose Tube's® Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDYTHREAD 40® I.) is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDVTHREAD 40® SPECIFICATIONS -I NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* 16./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 c®us LISTED APPROVED Lj 4 ,FPA *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masur OH BULL MOOSE TUBE COMPAJJY 63017 tt US YLITE® THE SUPERIOR LIGHTWALL IWDABLE Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". EddyliteO is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. r c®us LISTED I APPROVED no /4 ONFSA PdFPK 6 ADVANTAGES OF BULL MOOSE TUBE@ EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.236 37 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. t) A A <® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales©bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH BULL MOOSE TUBE COMRAPJY 63017 1ffI (e1ir XIfi? B uO Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® is a specially engineered • Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, • FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics • UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well • Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. • Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more • Supplied with EDDY GUARD Il® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE an opportunity for downsizing 11/4 1.660 1.530 1.98 1.222 2.019 61 and further cost savings. 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing r c®us LISTED APPROVED [40] 4A\ ONFSA NFPX PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH EULL MOOSE TUBE CCMPV 63017 MINE ES a Is yffi kTiF WPIPE- Bull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dr preaction, and deluge type sprinkler systems. Lightweight— saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NIPS O.D. ULTRA ULTRA EDDY8 WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 * Pressfit is a Registered Trademark of Victaulic Company of America ** Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling cus LISTED assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. <q> APPROVED c> A <f For Additional Information Contact (800) 325-4467 www.bulImoosetube.com EE 1J Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com NFPA ''''° 1 1 1819 Clarkson Road () Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masur OH UU.. MOOSE TUBE COMPANY 63017 8 jzi:r = I I c®us LISTED APPROVED [ii ONFSA RI .FPA NPS(IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 O.D.(in) 1.315 1.660 1.900 2.375 l.D.(in) 1.201 1.546 1.786 2.261 ULTRA EDDY' EmptyWeight(th/ft) 0.868 1.107 1.274 1.604 Water Filled Weight (lb/It) 1.359 1.920 2.360 3.344 O.D.(in) 2.17 1.40 1.660 1.11 1.900 1.00 2.375 2.875 3.500 4.500 ID (in) 1.530 1.728 - 2203 2.705 3.334 4.310 EDDY FLOW Empty Weight (lb/ft) 1.222 1.844 2.330 - 2.809 3.361 4.968 Water-Filled Weight (lb/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. OD (in) 1.315 1.98 1.660 3.44 1.900 2.78 2.375 1.66 2.875 1.00 3.500 1.00 4.500 l.D.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Empty Weight (lb/ft 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Water-Filled Weight (lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 CRR 0.D.(iri) 1527 1.315 991 1.660 776 1.900 627 2.375 492 354 250 1 D(in) 1.137 1.482 1.712 2177 EDDYLITEG Empty Weight (lbIft) 1.260 1.617 1.967 2.617 Water-Filled Weight(lb/ft) 1.700 2.364 - 2.965 - 4.230 . ......._. - CR.R. 0.13 0.08 0.12 0.16 - 0.D. (in) - 1.295 1.650 1.900 2.375 -I.a(in) 1.083 1.418 1.645 2.123 EDDYTHREAD 40 1.461 2.070 2.547 3.308 Water-Fified Weight (lb/ft 1.860 2.754 3.468 4.842 C.R.R. - OD (in) 1.00 1.315 1.00 1.660 1.00 1.900 1.00 2.375 2.875 3.500 4.500 - - ' 1.0(m) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 40 SCHEDULE Empty Weight (lb/ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 ,Wate!-Fil1ed Weight (lb/ftL 2.055 2.918.. - ..602 5.114 . 7.875 10.783 16.316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH BULL MOOSE flJEE COMPANY 63017 I7 IVNI5I L 1 21 II 24 25 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY® 0.868 91 1,659 1,896 1,975 SCHEDULE10 1.410 91 2,695 3,079 3,208 1 EDDYLITE® 1.260 91 2,408 2,752 2,867 EDDYTHREAD4O® 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2,470 2,822 2,940 ULTRAEDDY® 1.107 61 1,418 1,621 1,688 EDDY FLOW® 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2,760 11/4 EDDYLITE® 1.617 61 2,071 2,367 2466 EDDYTHREAD40 2.070 51 2,217 2,534 2,639 jSCHEDULE40 2270 51 2,431 2,778 2,894 r- ULTRA EDDY® 1.274 61 1,632 1,865 1,943 EDDY FLOW® 1.844 61 2,362 2,700 2,812 10 -..SCHEDULE 2.090 61 2,677 3,060 3,187 1-1/2 EDDYLITE® 1.967 61 2,520 2,880 3,000 EDDYTHREAD4O® 2.547 44 2,353 2,690 2,802 SCHEDULE 40 2.720 44 2,513 2,872 2,992 1 ULTRA EDDY® 1.604 37 1,246 - 1,424 1,484, EDDY FLOW' 2.330 37 1810 2,069 2,155 2 SCHEDULE 10 2640 37 2,051 2,344 2,442 EDDYLITE® 2.617 37 2,033 2,324 2,421 EDDYTHREAD40®J 3.308 30 2,084 2,382 2,481 SCHEDULE 40 3.660 30 2,306 2,635 2,745 F I EDDY FLOW® 2.809 1,770 2,022 2,107 2-1/2 - SCHEDULE 10 3.530 30 2,224 2,542 2,648 SCHEDULE 40* 5.800 3,654 4,176 4,350 EDDY FL0W 3.361 1,341 1,533 1,596 3 SCHEDULE 10, 4.340 19 1,732 1,979 2,062 SCHEDULE40* 7.580 3,024 - 3,456 3,601 EDDY FLOW® 4.968 1,982 2,265 2,360 4 SCHEDULE 10 - 5.620 19 2,242 2,563 2,670 - SCHEDULE 40* : 10.800 4,309 4,925 5,130 6 SCHEDULE 10 9.289 -. 10 1,951 2,229 2,322 8 SCHEDULE 10 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande, AZ c®us LISTED APPROVED no 4 ONFSA fr. "''•"' PIFPA ID E NGI IN S E EE EISl J Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & Ci for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 300 1 1/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1012 867 726 40 40 40 40 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) " According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 1 0.50 0.75 1.00 1 1.25 1 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 1 1/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 1 1/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <> APPROVED u; /4SA\ ONFSA IsIFPA D (D For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH BULL MOOSE TUBE CONIBANY 61017 11 Mechanical-I® STYLES 920 AND 920N Para CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved JOB/OWNER System No Location Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. 06 Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 113 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Date www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N 'NY tauIiC 11.02_i z 7-11 6i . IR ---~4t GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½/SO x 15mm through 8 x 4/200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. cm OW on, - _ - _va 11 2 ½ (a) 500 150 200 253 1.61 535 2.75 3.1 50 X 5 N 3450 381 51 64 - 41 136 70 15 - + + - -- N a) a 500 1 50 1.97 253 1.61 535 275 31 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) 500 1.50 1.85 253 161 535 275 30 25 920N 3450 381 47 64 - 41 136 70 14 - 1 A (a) ta 500 175 205 . 275 300 161 535 300 35 32 32 3450 445 52 70 76 41 136 76 17 1.5 - 4- - ± - I - - --- 4- + 1½ (a) to 500 1.75 203 275 312 1.61 5.35 325 36 3.2 40 3450 445 52 70 79 41 136 83 1.7 1.5 4- + + -4--- - ._•_ __ ,-._-F-_ 4- - 2½ x 1/2 (a) §a 500 150 221 2.74 1.82 5.64 2.75 3.0 65 15 3450 381 56 70 - 46 143 70 1.4 - - - - + -- - - - - + - -- , - 500 150 218 274 182 564 275 3.0 20 3450 381 55 70 - 46 143 70 1.4 - 1- - - .- --4 ---4- -4- 1 (a) §0 500 1.50 206 2.74 1.82 5.64 2.75 2.9 25 3450 381 52 70 - 46 143 70 1,4 - - - I - 4- - - - + 1 ¼ t (a) a 920N 500 1.75 2.30 3.00 3.25 1.82 6.29 3.00 3.5 3.2 32 3450 445 58 76 83 46 160 76 1.7 1.5 -4- - -- -4- ---------+-'-- -+ - - -4- - -,- - -,- 4- -- 1½ f(a) 500 200 2.28 300 325 1,82 626 3.25 3.6 3.3 40 3450 508 58 76 83 46 159 83 1.7 1.6 t- 76.1 x ½ (a) 300 150 222 275 225 6.46 3.18 3.9 15 2065 381 56 I 70 - 57 164 81 1.8 - - I--- - ----'- -4-- -- . 4--- --' 3/~ (a) 300 150 219 275 2.25 6.46 3.18 3.9 20 2065 381 56 70 - 57 164 81 1.8 - 1(a) 300 1.50 207 275 225 6.46 3.18 3.8 - ~ 25 2065. 38.1--4- - 53-1-- 70 - 164 81 1.7 - - -4- - - -.57 --- - - -4- 1¼ (a) 500 1.75 230 300 331 192 6.29 3.00 35 3.2 32 3450 44.5 58 76 84 49 160 76 16 1.5 4- .- -- -4- -------4- - -+ -- - . - + + .- 4-- - - 1½ (a) a 500 2.00 228 300 3.31 1.92 6.29 325 35 3.3 40 3450 50.8 58 76 84 49 160 83 1.6 15 - + - 3 ½ (a) 500 1.50 252 305 2.28 6.15 275 34 80 15 3450 38.1 64 78 - 58 156 70 1.6 - - 4- - - -- - -1----- -4- --- -4- -4- - 3K (a) n 500 1.50 249 305 228 615 275 3.4 20 3450 38.1 63 78 58 156 70 1.6 - ,-- . - , - -+ ---+---.- -,- -- --- -F 1(a) 500 1.50 238 3.06 228 615 275 33 25 3450 38.1 61 78 - 58 156 70 1.6 - - -1-' - - - 4-- - .4- - --4-, -- .4- - - -4- - -.- -4- 1¼ (a) to ' 500 1.75 2.55 325 356 228 6.15 300 3.8 37 32(b) 920N 3450 44.5 65 83 90 58 156 76 1.8 1.8 11/2 (a) f 500 2.00 2.78 3.50 356 2.28 6.15 325 41 38 40(b) 3450 508 71 89 90 58 156 83 19 18 - 1 ' --+ - -4- - ---4-- - * - 4- - - - 4-- - -4- 4- 2(a)u 500 250 275 350 356 228 675 388 49 4.6 50 3450 635 70 89 90 58 172 99 23 21 4- 4--- -- 4- - i - - 3½ 2 920N 500 250 300 375 244 672 . 388 38 90 50 3450 635 76 - 95 62 171 99 - 18 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services c LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X Ani-cMWM 11.022 REV_N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N TABLE CONTINUED FROM PAGE 2 4 x 1/2 (a) a 920N 500 1.50 303 3.56 2.69 701 2.75 3.7 100 15 3450 381 77 90 - 58 178 70 1.8 - 4 (a) a 920N 500 1.50 300 356 259 7.01 2.75 3.7 20 3450 381 . 76 90 - 68 178 70 1.8 - 1(a) a 920N 500 1.50 2.88 356 2.69 7.01 2.75 3.6 25 3450 38.1 73 - 4- - 90 - 68 _,. 4. 178 70 1.8 - 1 1/4 (a( i-a 500 1.75 308 3.78 -- 400 2.69 7.01 .4. 3.00 40 36 32(b) 3450 445 78 96 102 68 178 76 19 18 1 ½ (a) #500 - - t 200 -4- 3.28 - - ± 400 400 -I- - 269 701 - 3. 325 42 - 39 40(b) 3450 50.8 83 102 102 68 178 83 2.0 19 2(a) ta 500 2.50 325 400 400 269 701 3.88 5.0 46 50 - 1- 3450 635 + -- -4-------+- 83 102 102 68 . 178 99 2.3 2.1 2½ (a) t 920 500 2.75 2.88 ----4- 400 400 ,- - 269 734 - '- 463 -- 5.8 5.0 65 3450 699 73 102 102 68 186 18 - 2.6 2,3 - 4-.-- 4- --.--.-- 9 ,. - ---4--- ,- - 1- 76.1 mm 920 500 275 288 400 2.69 734 4.63 6.4 4- 3450 699 73 - 102 68 186 118 - 2.9 3 (a) t 920 500 -. 3.50 - -4.--- 331 450 - - 4.12 2.69 7.73 5.12 --4------- 8.4 6.4 80 3450 889 84 114 105 68 196 130 3.8 2.9 . + ----- -_-4.- - 4-- 4.- + ' ' 1 ¼ (a)a 1 x 500 1.75 308 378 263 764 3.05 5.0 . 32 - - 3450 445 78 -4 96 ------4- 67 194 78 2.3 - 11/2 (a)r' 500 200 -- 3.28 4.00 -+ - - 2.63 764 1- -. 3.25 - 4- 5.0 - 40 3450 508 83 102 - 67 194 . 83 2.3 - 2 (a) 500 2.50 3.25 ---------..-- 4.00 -4- 253 764 4.00 .....- 4.0 50 1- 3450 635 - - ---r 83 --4 102 -----4-- - - 67 4- - 194 ' 102 1.9 -' -- - 76.1 mm 500 2.75 2.88 4.00 400 263 7.64 ' 4.29 8.0 - 7.8 3450 699 73 102 102 67 194 109 3.6 3.5 3(a) 920 500 350 331 4.50 450 2.63 7.63 4.88 6.8 6.5 80 - + 920 3450 - 500 889 - -- 200 84 - .4-.- 403 114 475 ---- 114 475 .I. 67 --. 316 194 9.70 124 - 4- 3.69 3.1 -9-- 7.4 3.0 7.6 5 1½ (a)t X 125 40 3450 508 102 -4-- 121 - -. 121 80 246 94 -1- 4- 3.4 3.4 2 (a) 6 920 500 2.50 400 475 475 3.16 9.70 4.38 8.2 8.0 50 3450 635 102 121 121 80 246 111 3.7 3.6 21/2 (a) 6 920 500 2.75 3.63 475 475 3.15 9.70 + - 463 8.3 7.9 65 3450 699 92 121 121 80 246 118 3.8 3,6 + - 500 '4- 275 t 76.1 316 - 375 - - 475 970 463 - - - - 8.0 mm a • 3450 - .- 699 ----9- 95 - 121 - 80 4- - .- - 246 118 - 3.6 3(a) t 920 500 3.50 381 --4--------4--- 5.00 463 316 970 - - 531 .-+ 8.4 - - 8.8 80 - -±--- 3450 9- 500 88.9 -4-- 2.50 97 - -I--- 375 127 - 4.50 118 - 80 -- 4- 317 246 - - - 800 135 3.8 - + - - - 4 388 8.0 4.0 - 2 1 x . 50 3450 4- 635 .4- 95 + 114 - - 81 + - -- 203 99 3.6 - 920 500 3.50 3.81 - - 5.00 300 9.46 -4---.-.- 5.31 8.0 80 3450 88.9 97 127 . - 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 Lenter or run to engaged pipe end, temale threaded outlet only (dimensions approximate). 6 Available with grooved or female threaded outlet. Specify choice on order. I: Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N _A't1lbUu1C• 11.023 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. TABLE CONTINUED FROM PAGE 3 ½-f 397 X 920N 500 200 378 450 330 823 325 70 40 3450 508 96 114 84 209 83 32 - 2t - 1• + - - - -,- 500 250 375 450 - - -4---. _.__.•_ 330 823 + - 388 90 -1- 50 —1— N 3450 -F 500 63.5 95 114 175 443 513 - - --I-- - 513 84 379 209 99 915 325 4 51 48 6 114(a) < 150 32(b) 3450 445 112 130 130 ' 96 232 83 23 22 1 1/2(a)t 500 200 440 513 513 379 915 325 + 54 ' 51 40(b) 3450 508 112 130 130 96 232 83 24 23 2(a)lm 500 250 1 438 513 513 379 915 388 6.0 56 50 3450 . 635 111 130 130 96 232 99 27 25 4- 21/2 920 500 275 401 513 512 i 369 1051 463 83 76 65 -1- 3450 699 110 130 .. - - . 130 _-._...4_-.-.___.. 94 267 ..4___-. .4- 118 38 34 + - 76.1 mm 500 275 415 521 369 1051 --+ 463 84 3450 - 699 105 132 94 267 118 - 38 -- - - _-- +. -+ --4- 3 (a) t 920 500 350 431 550 5.13 369 1051 531 99 84 80 3450 889 110 140 130 94 267 135 45 38 * I -- - — 4 (a) to 920 500 450 381 575 538 369 1051 625 101 101 100 3450 500 1143 97 I 146 - - * 200 441 I 513 137 - 94 - 363 267 -- - -- 940 159 - I 325 46 78 46 1½(a) igo < 40 920N 3450 508 112 130 - 92 239 83 35 - - 1— -- - .- -- -. - 1- --- + - - -+ -- -.- - .-+-- - 2(a) 500 , 250 438 513 I 363 940 388 80 50 3450 635 11 130 - 92 239 99 36 - 500 - 4.. .. 275 438 550 .5 _ - - _• —. .4.. 76.1 mm 5.13 363 940 463 95 95 3450 -I- — 699 1 1 140 - +___I]] - - +- 130 92 - 239 .4--- — * 118 43 43 4- — 3 920 500 350 431 550 - 513 , 363 940 — -1----- 531 81 140 80 3450 889 110 140 130 92 - 239 .4.. . 135 37 6 mm 500 450 445 538 363 940 , 6+12 .___f -. 00 3450 + - t 1143 113 - - - -— 137 * 92 - 239 + 155 45 - - - 920 500 450 381 575 363 940 625 180 100 3450 1143 I 9680 . 146 - 92 239 159 82 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 4 Available with grooved or female threaded outlet. Specify choice on order. * center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals company. DIMENSIONS 04. 9111 All GROOVED OUTLET V~ Ff-: Y F -r- Z FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vlcrAuLIc COMPANY. ALL RIGHTS RESERVED. 11.024 REV CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1/2750 x 15mm through 8 x 4/200 x 100 mm _ I F I2S TABLE CONTINUED FROM PAGE 4 1 165.1 x 920N 500 150 388 4.56 379 9.34 2.75 8.0 25 3450 381 99 - 116 96 -+- -- . . 237 70 .4- .4.-- 3.6 - 1¼ 920N 500 175 443 513 379 934 325 84 + 32 3450 445 113 - 130 96 237 83 38 - 11/2 (a) to920N 500 2,00 4.41 5.13 513 379 934 325 84 54 40 - 3450 50.8 112 130130 96 237 83 3.8 2.4 2 (a) t 500 2.50 438 5.13 5.13 3.79 934 3.88 8.5 60 50 3450 635 111 130 130 96 237 99 3.9 27 76.1 mm 920 500 275 401 5.13 5.21 363 1051 463 8.6 76 3450 699 110 130 132 92 267 118 3.9 34 3(a) t - . 4. 500 350 .4-. ____•_.____ 4' . -4. 4.31 5.50 5.13 3.63 1051 -• I' 531 - 10.2 84 80 920 3450 889 110 140 130 92 267 135 46 38 4(a)t2 500 450 381 4- 575 538 363 1051 625 105 84 100 920 920 - - - .4____ 3450 500 1143 275 97 544 146 137 92 .4.. - _... -- - ,. 619 625 481 267 1242 ' 159 . 450 48 38 . .4. .. - 116 116 8 21a1t 200 50 3450 69.9 138 157 159 122 316 114 5.3 53 2½ (a) t 920 - 4- 500 2.75 -'•'-- 507 '4- - ,--' - 4- 619 619 481 - 1242 . 4' 4.50 + 11.6 116 65 3450 69.9 129 157 157 122 316 . 114 5.3 53 76.1 mm 1 920 500 275 525 625 481 1242 456 116 3450 699 133 159 122 316 116 - 53 3(a) to 920 500 350 531 650 650 481 1242 5.31 12.6 11.6 80 3450 889 135 165 165 122 316 135 57 53 4(a) to 920 500 450 48 675 638 481 1242 6.25 153 125 100 3450 1143 122 171 162 122 316 159 6.9 57 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/a" BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV,,N JtiUIicr 11.025 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA ® rs Exaggerated for clarity Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalT® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for C111K Values: AP = Q2 Where: - AP = Q2 Where: 0 = Flow (GPM) K 2 Q = Flow (m3/hr) 6P = Pressure Drop (psi) tsp = Pressure Drop (Bar) Q = C x j2 C = Flow Coefficient Q = K, x K = Flow Coefficient ½ 15 0.840 21.3 3/~ 1.050 20 1 26.7 - - 1315 25 37 1¼ 1.660 32 42.7 1 ½ 1.900 40 98.3 - 2 2.375 50 60.3 2½ 2.875 65 76.1 mm 3.000 76.1 3 3.500 80 88.9 4,500 100 114,3 2 - - - - - - - , - - + 9.4 16 - - - - - , 13.7 - 21 3. ,- - 1.8 0 48 5½ 6 42.9 41,1 53 53 11 11 45.4 112 104 9 10½ 96 89.1 119 150 20 12½ 102 1285 161 16' - 1381 - 249 237 14 15½ 213.4 203.1 421 401 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in./4.2mm. 1" FireLock" Innovative Groove System (IGS) outlet www.victaulic.com Jt1EauIicr vicTAuLic IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.026 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0- 168.3 2.875 - 4.500 All DF 2755 300 2755 300 2755 300 1999 290 1599 232 2496 362 21/2-4 65-100 73.0-114.3 2.875 - 4.500 . - ' All - - SF 2065 300 - - 2065 - - 4- 300 2065 300 .- +-- 1999 - 290 1599 232 2496 362 21/2 - 4 65-100 73.0-114.3 6.625 -- -4- ------4- 4 10 2065 ---- 300 ~- 2065 - 300 2065 . 250 1999 290 1599 232 2496 362 6 150 168.3 - -4- 6.625 —4- - - + 40 2065 300 + 2065 - 4- 300 1724 300 -------- 1999 - . 290 1599 - - 232 2496 - 362 6 150 168.3 - - - - + 8.625 . .4- 21/2 ---- -.- 1040 2065 -- .--- 400 --1---- 2065 - + - 2065 - 1999 1 - 1599 145 2496 - 8 200 219.1 8.625 1 2755 300 - 250 1000 145 - 8 200 219.1 8.625 ' 34 - 30,40 2065 300 - 1724 300 - - 1000 145 - 8 200 219.1 2065 2065 ------- 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. OF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR 4 - 8/100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 4"/100mm, 57125mm, 67150mm and 8'7200 mm diameter pipe. The Style 931 comes with a 2 ½765mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVN 'JtuIicr 11.027 MechanicaT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 148O REV N UPDATED 12/2017 x10 iCtuIiC vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L FireLock® STYLE 922 Para CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved JOB/OWNER System No. Location The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-I is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) Date www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vICTAuLIc COMPANY. ALL RIGHTS RESERVED. REV_G \ AC_ ta ulicf 10.521 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS Y i-z- 4"''JL.. r vi -- j F -LI fs 1¼ x ½ 1/ 1.30 1.83 .10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 - 27.9 ,9&3 65.0 0.45 T Y4 1 1.28 1.83 1,10 3.87 2.56 1,1 - 20 - 30.2 325 46.5 27.9 98.3 65.0 050 6 - W 1 1 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 1/2 13A6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 -- 1-' - -1- Y4 1 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 - -,---- .4-------- .. + - - 1 1 3A6 1.64 2.30 122 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 - 2 1/2 13A6 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 - .4- --------+ --'-4--.--- .- . . - .,. - -- - 3/~ 1 3A6 1.64 2.19 , 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 - ...........-- -l----------f- -_ ,, - ., + 1 1~6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 -- .--- -4- --.- .- 21/2 1/2 1 3A6 1.91 2,44 1.71 5,40 2.56 1.6 65 15 30.2, 48,5 + - - -- - 62.0 43.4 137.2 65.0 0.73 - - . ..- , --- 3/4 1 3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 -4--- -.---- . - 1 1 3A& 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 - - 761 X ½ 1 /l6 1.91 2.44 1.71 5.50 2.56 1.6 mm 15 30,2 - 48.5 - 62.0 - , 43.4 - 139.7 65.0 0.73 3/4 19¼ 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 ' 62.0 43.4 139.7 65.0 0.73 + ----. 1 1 3A6 2.13 . 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 . 43.4 139.7 . 65.0 , 0.80 t Victaulic female threaded products are designed to accommodate standard NPTor BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NFl threads (dimensions are approximate). www.victaulic.com \,#tauIic.° VICTAULIC IS REGISTERED TRADEMARK OF VICTAuLIc COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.522 REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com - - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAUUC COMPANY. ALL RIGHTS RESERVED. ctauI,c REV_G 10.52_3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic VICTAULIC IS REGISTERED TRADEMARK OF vICTAULIc COMPANY. © 2009 vicTAuLic COMPANY. ALL RIGHTS RESERVED. 10.52 Ductle Ircn Threaded Fttdngc '0MITH..~C00PEW Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP eo Ductile iron castings conform to ASTM A536 C US LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 <i Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 500 200 480 250 460 300 440 350 420 400 400 450 380 ---500 360 550 340 320 600 650 300 Size in Part Number A in B in Packing Weight lb Inner I Master 3/4 x1/2 1 x 1/2 1 x3/4 35RE3006004 35RE3010004 35RE3010006 35RE3012004 35RE3012006 356E3012010 1.20 1.22 1.36 - 1.45 1.53 1.63 1.67 1.75 80 70 50 35 35 30 30 25 20 18 18 18 16 12 10 6 6 160 140 100 70 70 60 60 50 40 36 36 36 32 24 20 12 12 0.3 0.4 OA 0.5 0.6 0.7 0.6 1.26 1.38 1.34 1-1/4 x1/2 1-1/4 x3/4 1-1/4x1 1.45 1.58 1.52 1-1/2x1/2 1-1/2 x3/4 1-1/2x1 1-1/2x1-1/4 2x1/2 ,?.x 3/4 2 x 1 2x1-1/4 2x1-1/2 35RE3014004 35RE3014006 35RE3014010 35RE3014012 35RE3020004 35RE3020006 35RE3020010 35RE3020012 35RE3020014 1,52 1.75 1.80 1.88 - 1.97 1.97 2.02 2.10 2.16 0.7 0.8 TO 1.0 1.0 1.2 1.3 1.5 2.2 2.5 1.65 1.82 1.60 1.60 1.73 1.90 2.02 2-1/2 x 1-1/2 35RE3024014 2.16 2.39 2.51 2.60 2-1/2x2 35RE3024020 Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 1-1/4 1-1/2 2 Z-112 35F 3004 35F 3006 0.88 150 300 160 80 50 40 20 8 0.2 0.3 0.5 0.7 1.0 - 1.6 - 2.7 0.98 1.13 80 40 35F 301 0 35F3012 35F3014 35F3020 35F3024 1.29 1.44 25 20 10 1 4 1.69 1.95 1 1 iLxrFth1 j '- c(DUS APPROVED Fig. 35E 3_900 Elbow LISTED Size Part Number U A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 - -35E 3606 1.31 70 140 0.3 1 - 35E3010 1.50 40 80 0.5 1-1/4 35E 3012 25 50 0.8 1.75 1.94 1-1/2 35E3014 18 36 1.1 2 _35_E3620___ _2.2_5 T .25 10 20 1.8 2.70 2-1/2 35E 3024 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 -- 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1.1 1-1/2 3513014 1.94 10 20 1.5 2 35T3020 6 12 2.4 2.25 2.70 2-1/2 3513024 4 8 4.3 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x1/2 35RT3006004 1.20 1,20 1.22 60 120 0.4 lx l/2 35R73010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35RT3010004010 1.50 1.36 1.50 30 60 0.6 1x 3/4 35RT3010006 1.38 1.45 25 50 0.6 1.38 1x3/4x3/4 35R13010006006 1.38 1,31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R73012004012 1.75 1.53 1.75 25 50 0 1-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x1-1/4 35R13012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4xlxl/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x1x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 4xlxl 35RT3012010010 1.58 1.50 1.69 20 § 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 . 30 1.0 1-1/2x112 35RT3014004 1.41 1.41 1.66 16 32 1.0 1.81 1.1 1-1/2x1/2x 1-1/4 35RT3014004012 1.56 1.88 24 48 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 1.52 1-1/2x3/4 35RT3014006 1.52 1.75 16 , 32 1.1 1-1/2x3/4x 1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 2 . 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 , 1.67 1.88 12 24 12 1.94 1-1/2x1x1-1/2 35R13014010014 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1.4 1-1/2x 1-1/4x 1/2 35RT3014012004 1.41 1.34 - 1.66 16 32 - 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.45 1.75 16 32 to 1.52 35RT3014012010 1.65 1-1/2x1-1/4x1 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.75 1.88 14 28 1.3 1.82 1.94 1-1/2x1-1/4x1-1/2 358T3014012014 1.88 1.94 14 28 1.4 2x1/2 35R73020004 1.49 1.88 10 20 1.5 1.49 2x3/4 - 35R13020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 6 16 1.7 2.02 2x 1 x2 35RT3020010020 2.25 2.25 8 16 1.9 2x1-1/4 35R13020012 1.90 2.10 8 16 1.9 1.90 2.25 2.10 2x 1-1/4x2 358T3020012020 2.25 8 16 2.0 2x 1-1/2 - 35R13020014 2.02 2.16 8 16 2.1 2.02 1.49 2x1-1/2x1/2 35RT3020014004 1.41 1.88 10 20 1.3 ?x1-1/2 x 3/4 35RT3020014006 1.52 1.97 10 20 1.4 1.60 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 2x1-1/2x1-1/4 35RT3020014012 1.82 2.10 8 16 1.7 1.90 2.02 2x1-1/2x1-1/2 35RT3020014014 1.94 2.16 8 16 1.8 C@US APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size A B C Packing Weight Part Number Inner Master in in in in lb 3/4x1 35BT3006010 1.45 1.45 1.37 30 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.58 20 40 0.9 1.67 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35B13012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35B13012014 1.88 1.88 1.82 15 30 1.3 - ----- 1-1/4x2 35B73012020 ------.---------- 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 35BT3014012020 2.16 2.10 2.02 .. 10 - 20 1.8 1-112x2 358T3014020 2.16 2.16 2.02 8 16 1.8 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com 112 ceus APPROVED Fig. 3503 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 350P3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 - 2 350P3020 15 30 1.2 2.62 3.00 9 2-1/2 350P3024 18 2.2 Size in Part Number A in Packing Weight lb Inner I Master 1 x 1/2 35HB3010004 1.06 180 360 0.2 1x3/4 35H83010006 1.06 180 360 0.1 1-1/4 x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 75 150 0.4 1.25 1-1/2x1-1/4 35HB3014012 1.25 75 150 03 2 x 1 35HB3020010 1.38 40 80 0.6 1.38 2x 1-1/4 35HB3020012 40 80 0.6 2x1-1/2 35HB3020014 40 80 0.6 1.38 Fig. 35SP3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 350 700 0.1 1.12 1 35SP3010 1.25 200 400 - 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4-- T_ 35SP3020 45 90 0.6 1.50 _Mnh~_9m WIN! 11111111111111111[ 11 11 ~ '1 11 1 Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1 x3/4 1-1/4x3/4 35RC3010004 35RC3010006 35403012006 I 35R03020010 1.69 1.69 80 60 160 120 80 40 - 0.3 0.4 0.6 1.0 2.06 2.81 40 2x 1 (not hex) 20 Fig. 35HB3 -Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number ______________ A in Packing Weight lb Inner Master 1 35U 3010 2.19 20 40 1.0 1-1/4 35U 3012 2.50 15 30 1.2 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® 9 TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 9 www.smithcooper.com Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4-- 1.94 1-112 35X3014 8 16 - 1.8 2 35X 3020 2.25 6 12 2.8 Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 1-1/4 1-1/2 2 3503004 3503006 3503010 35C 3012 3503014 3503020 35C3024 0.87 0.97 1.16 300 200 110 70 50 25 18 600 400 220 140 100 50 36 0.1 0.1 0.2 0.4 0.5 0.8 1.6 1,28 1.33 1.45 2-1/2 1.70 Fig. 35BC3 - Beam Clamp Fig. 3513- Cross i &Lus<~> APPROVED LISTED Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2x1 35RX3014010 1.80 1.65 12 24 1.4 2 x 1 35RX3020010 2.02 1,73 8 16 2.0 .I1 Fig. 35C 3- Cap Size in Part Number A in Packing I Weight I lb Inner I Master 3/8 - 35803003 0.75 100 200 0.3 1/2 35B03004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/ADorovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor =~fflejBS <*> APPROVffi Indeoendent code evaluation IBC®/ IRC® 2015 IBC®/ IRC® 2012 IBC®/ 1RC82009 lBC®I IRC®2006 Hilti, Inc. (US) 1.800-879.8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hittica I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications12 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter db, in. 1/4 Nominal embedment h00,0 in. 1-5/8 2-1/2 Effective embedment h f in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T,nst ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size _da !anch -I..-- he - nato h Table 2 - Hilti KWIK HUS-EZ I design strength with concrete/ pullout failure in uncracked concrete', 2,3,4,5 Nominal Nominal Tension - 4N Shear - On anchor embed. f1c = 2,500 psi f = 3,000 psi f = 4,000 psi f',=6,000 psi f,, = 2,500 psi f',= 3,000 psi f'c = 4,000 psi ic = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 / (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2,3'4'5 Nominal Nominal Tension - cpN Shear - cpV anchor embed. ic = 2,500 psi f = 3,000 psi f' =4,000 psi ic = 6,000 psi ic = 2,500 psi f = 3,000 psi f',=41000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 / (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - aN = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNS = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear' Seismic shear' diameter thread diameter 4N I. 4V in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension cpN = 4A NfuS as noted in ACt 318-14 Chapter 17. 4 Shear determined by static tests with cpV < 0.64A50 f,,,0 as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with 4)V s 4) 0.60 A 0 f,,, as noted in ACl 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1.800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' .1. toward edge from edge factor in shear3 uncracked concrete fRN f1V fRV f1V 'HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h~om (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a CD 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 8 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a - - 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 T 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 CD 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CO 10 (254) 0.89 11 (279) 0.93 12 (305) 0.97 - 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .1. toward edge from edge factor in shear3 cracked concrete f111 I RN 'AV fRy fRy 1HV______ Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0,,, (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 1 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 ca 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 to XM 5-1/2 (140) 0.98 0.83 0.72 0.93 . 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 a 10 (254) 0.90 11 (279) 0.94 12 (305) __ 0.98 - 14 (356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f A, assumes an influence of a nearby edge. If no edge exists, then fAV = IAN 4 Concrete thickness reduction factor in shear, f, assumes an influence of a nearby edge. If no edge exists, then I HA = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hifti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWlK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,1,4,5,6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N, Shear - Tension - qN Shear - anchor thread embed. f',,= 3,000 psi f.= 4,000 psi f'= 3,000 psi f,= 4,000 psi f'= 3,000 psi f',= 4,000 psi f = 3,000 psi f.4,000 Ps diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWlK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,1,4,1,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - cpN, Shear -4V,, Tension - pN, Shear -clV, anchor thread embed. f'= 3,000 Psi 4,000 Psi ',= 3,000 Psi = 4,000 psi f',= 3,000 psi f',= 4,000 psi f= 3,000 psi f',= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / ______ 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,,,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,00i0 = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - a., = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800.879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies - Mm. 3/4 ) •.3 Min. 3.000 psi sand- lightweight I-weight concrete 2r norma flute -9 —Anchor P M(tyal) (2 Minimum IL 20 gauge Min. 4-1 Flute edge - Lower (typical) flute Mm. 1-1/4"- Mm. 12 (typica (ridge) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. H 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile Shear4 Shear4 diameter in. diameter N r V r Vsareq (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N futa R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v, <A,0 4 0.6 f, R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V, <A5 4 0.6 futa R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800.879.8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-448 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D' H Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. da in. 1/4 (mm) (6.4) Effective embedment2 In in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment' h nom in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness 4-1/8 h in. 3-1/4 min (mm) (83) (105) Critical edge distance C, in. in. 2.00 2.78 (51) (71) Minimum spacing at critical edge distance S fljflcac in. 1.5 (mm) (38) Minimum edge distance C fl in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 (mm) (51) (73) Minimum specified ultimate strength f psi 125,000 uta (N/mm2) (862) Effective tensile stress area A aeN in 0.045 (mm2) (29.0) Steel embed, material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension N lb 3,370 D.6.11.2 (kN) (15.0) Factored steel resistance in shear V r lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) Factored steel resistance in shear, seismic V eq lb 335 (kN) (1.5) Factored steel resistance in shear V, lb 725 D.7.11.2 3/8-16 UNC internal thread _ (kN) (3.2) Factored steel resistance in shear, seismic V ar,oq lb 620 (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete kcuncr - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc .4 c.N - 1.0 D.6.2.6 Anchor category - - 3 1 D.5.3(c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R Condition B5 - 0.75 1.00 D.5.3 (c) Factored pullout resistance in 20 MPa uncracked concrete6 Np,uncr lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete6 Nprcr lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete6 Nprw lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with GSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by GSA A23.3-14 Annex D section D.2. For all design cases, ip6 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k 0) or uncracked concrete (kncr) must be used. For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, ip1, = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2,3,4,6 Nominal Tension - N ___________ ________________ Shear - V I , = 20 MPa f' = 25 MPa f' = 30 MPa f' = 40 MPa f' 20 MPa f' = 25 MPa I = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed, embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 1 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12- Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concretelZ345 Nominal ___________ Tension - N Shear - V f', = 20 MPa IC = 25 MPa f' = 30 MPa I = 40 MPa IC = 20 MPa IC = 25 MPa IC = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900ps1) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) q 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth -O(N,.I~= 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, inc. (US) 1-800-879-8000 1 www.us.hilti.com I en españoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck"2'3'4'5'6'7 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - Nr Shear - V Tension - Nr Shear - Vr anchor thread embed. I = 20 MPa = 30 MPa f', = 20 MPa I = 30 MPa f. = 20 MPa I = 30 MPa f, = 20 MPa I = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWlK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' Z3,4,5,6,7,8 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear - V, Tension - Nr Shear - Vr f, = 20 MPa I = 30 MPa f, = 20 MPa f, = 30 MPa f' = 20 MPa IC = 30 MPa f, = 20 MPa f, = 30 MPa anchor thread embed. diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 4 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 L 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASO value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,,,,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - 0.45 For the 1/42-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, inc. (US) 1-800-879-8000 1 www.us.hilti.com i en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 .4- ) location , KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete nanels1'2 Hanger rod size Mm. effective embedment het in. Allowable load3 Ultimate load Tension lb Shear lb 4.5 Tension lb Shear lb4'5 1/4-20 UNC 1-3/8 1 455 485 1,810 1,930 3/8-16 UNC 1 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete [A 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty / box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hitti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 25 - Surge Restrainer c®uS LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 B-Line Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 i tJIX 4. ? Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c YL US USTED Seismic Restraints System Size Range - Secures 3/8 thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Plannina and Development (OSHPD). For additional load, spacing and placement information relatinajo OSHPD oroiects, olease refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range — Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750° F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions ° Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY 1375 SAMPSON AVE. CORONA, CA 92879 P1-I: 951.7375599 FAX: 951.737.0330 CUSTOMER SERVICE 800.786.5266 www.tolco.com Fig. 200-1 to 200-2 Fig. 200.21/2 to 200-8 Fig. 200 Fig. 200F Fig. 200S llip:eiAangiei,is ___m - Wil Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) CITOLCCY Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) L us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) C@ Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut USTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C 0 .c (co 200-1/2 1/2° (15) /81-16 31/8 (79.4) 2I8° (66.7) 11 (5.0) 200-I4 3/4 (20) /8"-16 31/8 (79.4) 21/2 (63.5) 11 (5.0) 200-1 1 (25) /8°-16 3/81, (85.7) 2I8° (66.7) 12 (5.5) 200_11/4 11/4 (32) /8"-16 33/4 (94.0) 2/8' (73.0) 13 (5.9) 200_11/2 11/2 (40) I8°-16 3/8" (98.4) 2/81, (73.0) 14 (6.4) 200-2 2° (50) /8"-16 41/2 (114.3) 3' (76.3) 15 (6.9) 200_2112 21/2 (65) /8"-16 5/8 (142.9) 41/8 (104.7) 27 (12.3) 200-3 3° (75) /8°-16 5/8" (149.1) 4° (101.6) 29 (13.3) 200_31/2 31/2° (90) /8°-16 7/8° (187.3) 51/4 (133.3) 34 (15.6) 200-4 4° (100) /8°-16 7/8° (187.3) 5° (127.0) 35 (16.0) 200-5 5° (125) 1/2 '_13 91/8° (231.8) 61/4° (158.7) 66 (30.2) 200-6 6° (150) 1/2°_13 101/8 (257.2) 6/41, (171.4) 73 (33.4) 200-8 8' (200) 1/2°..13 131/8 (333.4) 8I4 (222.2) 136 i (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200-2I2 to 200-8 ØVOLCO C @ tIS LISTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe 44 types and protect CPVC plastic pipe from abrasion. Captured design : keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) Fi 200-1 to 200-2 in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. 200M8-1/2 1/2" (15) M8 31/8 ' (79.4) 2/8" (66,7) 11 (5.0) 200M10-1/2 1/2' (15) M10 31/8" (79.4) 2f8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M1O 31/8" (79.4) 21/2 (63.5) 11 (5.0) 200M8-1 ill (25) M8 3I8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) M10 3/8" (85.7) 2/8' (66.7) 12 (5.5) 200M8-1114 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2/" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3/8" (98.4) 2/8" (73.0) 14 (6.4) 2001Y18-2 (50) M8 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 2' (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-2112 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3' (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 .,4" (100) 1010 7 /8" (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4 (158.7) 66 (30.2) 200M-6 6" (150) M12 101/8 (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8 ' (333.4) 8I4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line DLCO C® US LISTED P:eiiIng:eiis. - - I I Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2°.13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cLIL). Conforms to Federal Specification WW-H-171 E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. 200H-2-3/8 2" (50) /811-16 4/16' (115.9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2°.13 423/32" (119.8) 33/8" (85.7) 45 (20.4) 200H-2112-318 21/2° (65) /8"-16 55/16' (134.9) 323/32" (94.4) 59 (26.7) 200H-21 I2_1 /2 21/2° (65) 1/2"_13 515/32' (138.9) 37/8" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8"-16 53/4" (146.0) 327/32" (97.6) 63 (28.6) 2001l_3_112 3" (75) 1/2"_13 5/8" (148.1) 331/32 (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2"_13 71/32' (178.6) 419/32' (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line ffiffeffi~~~ ~Lu 1 ffill !b r Rea n t 11- 9, Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. 01 F PP I® Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G RS/1- SVSTM cOMPAliBLE *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 + 1 800 344-1822 FAX +1800344-3775 ffm © 2012 Fire Protection Products, Inc. FPPl, LubeRIO are registered trademarks of Fire Protection Products, Inc. FGGIBM/CZ, Blaze-Master,", FlowGuard Gold and Corzan5 are registered trademarks of Noveon IP Holdings Corp. MAUE U.S.A. Fi Th read Se aling Pa ste (Th () Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com © 2012 Fire Protection Products, Inc. FPPI®, LubeHt' are registered trademarks of Fire Protection Products, Inc. FBC', BlazeMaster, RowGuard Gold® and Corzan® are registered trademarks of Noveon IP Holdings Corp. I Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. 09 it ng M 1"Tih, rime-an I I E- I R, V -ad IN ft i I Fit i7tt I h "ne Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. I ThreddFiF J Th,,od Coning Oil Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke F12CV::7A SYSTEM COMPATIBLE *FBCO System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE F CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gL Pail 55-gl drum 275-gi tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hotline. They may be reached at 1 800 424-9300. © 2013 Fire Protection Products, Inc. FPPIA, mreadFiP are registered trademarks of Fire Protection Products, Inc. LA MADE IN U.S.A.