Loading...
HomeMy WebLinkAbout1161 CHESTNUT AVE; ; FPR2020-0028; PermitPERMIT REPORT (ity of Carlsbad Print Date: 04/26/2021 Job Address: 1161 CHESTNUT AVE, CARLSBAD, CA 92008-2512 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2052109600 Track #: Valuation: $568,121.41 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Plan Check #: Permit No: FPR2020-0028 Status: Closed - Finaled Single Family Fire Sprinkli Applied: 03/30/2020 Issued: 06/22/2020 DEV2018-0063 Finaled Close Out: 04/26/2021 Inspector: Final Inspection: Project Title: CHESTNUT AVENUE RESIDENCE Description: CHESTNUT AV GOLDMAN RESIDENCE -NEW 13D SYSTEM (34 HEADS) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 12155 PAINE PL 12155 PAINE PL POWAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department 0 Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov HydrauIic Summary Job Number: 20-0146 Paxnnrt flaxm.rr1ntjron P;=1 I I-lrit 113 Job Job Nurrrber : Design Engineer 20-0146 TIM DE KONING Job Name: SUre CenlifsatioryLioeree Number CHESTNUT AVE RESIDENCE Address I AHJ 1161 CHESTNUT AVE j CARLSBAD FIRE DEPT - Addrnss 2 - - Job Site/Building - - CARLSBAD, CA 92008 Address 3 - - Dtecdng Name 200146_CHESTNUT RES System Remote Area(s) Most Demanding Sprinkler Data Occupancy Job 55Db 4.9 K-Factor 21.00 at 18.367 RESI 1 HD Hose Agowanre Al Source Density - tArea alio onypplic n - - 0.00 0.050gpm/ft2 400.00ft2 (Actual 142.49ft2) Additional How Supplies - - NurrtherOfbpeinMersCalcdated Nurnb000tNeezteoCalculated CoveragePerSprinlder Node Flow(qpm) 1 0 400.00ft2 Hose At Node 5 5.00 AutoPedkResrOts: Pressure Far Renrota kee(s) Adjacent To Most Remote Area Total Hose Streams 5.00 System FtomDemand TotalVublerReyuired(lnolndingHosepJlocoanca) 26.00 26.00 Maoimum Pressure Unbalance in Loops 0.000 Marimum DeAcon Aboce Ground 11.23 between nodes 9 and 101 MacjnncmVelocity Under Ground 10.73 between nodes 1 and 2 ntOAunre capacity oty*t Pipe, Volume capacity of Dry Pipes 64.o4gal Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node Name (gpm) (psi) (psi) (gpm) : (psi) (gpm) (psi) (psi) 1 Water Supply 98.000 88.200 500.00 97.959 : 26.00 73.066 24.893 Contractor Contractor Number 20-0146 ConOect Name Contae Title Name or Contractor Phone I Extension SYMONS FIRE PROTECTION Address 1 FAX 12155 PAINE PLACE r Addrebs2 POWAY, CA 92064 E-mail Address 3 Vtab.Sile , ©M.E.P.CAD Inc. aj AutoSPRINK 2019 v15.1.15.0 3/26/2020 10:57:43AM Page 1 ffl[Hydraufic Graph I D Job Number: 20-0146 Pnn,t fl ,nntinn' PI I I-Ifl (1' Water Supply at Node I 100— Static Pressure 98.000 90--- 0 I O2_____ I 00 73.066 60— U) 50— S fstem demand curve 40- 20- 10-1 111.LI.LL.1.1.1.1.1.1..1.lhhhhhhhhl 11111111 IIIlIII IIIIII I III liii 111111111 I II I I I I I I 0 — 200 400 600 800 1000 00 300 500 700 900 Water flow, gpm HydrUo Graph Water Supply at Node I Static Pr.- 98.000 RidI Pru 88.200 @ 500.00 Avait.b Pressure at lime of Test 97.959 @26.00 System N- 73.066 @26.00 Sy.tem Dem.M tekrprg HOSe HNOre.Ce II $oroHel 73.066 @26.00 (, © M.E.P.CAD, Inc. JR AutoSPRINK 2019 v15.1.15.0 3/26/2020 10:57:44AM Page 2 ode Analysis Job Number: 20-0146 Report Description: RESI 1 HD (1) Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 1 -3-0 S 73.066 26.00 5 40 T(5O) 40.270 5.00 101 19-0 Spr(-18.367) 18.367 21.00 2 -1 -0-0 WMV(-4.000) 67.723 3 - -0-0 11 E(7-0) 49.515 4 -0-0 E(2-8%) 43.214 6 6-6 E(40) 37.016 j 7 8-6 1(3-0) 3.4.719 9 19-6 1(3-0) 21.813 10 19-6 1(3-0) 25.086 + 11 19-6 T(3-0) 24.540 © M.E.P.CAD, Inc. Q AutoSPRINK 2019 v15.1 .15.0 3/26/2020 10:57:46AM Page 3 Hydraulic Analysis 11 Job Number: 20-0146 6 Report Description: RESI 1 HD (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Route ..... DR 0.8740 21.00 11.23 150 0.229253 4-11% Pf 3.663 101 19-0 21.00 4.9 18.367 Sprinkler, 11-0 Pe -0.217 9 19-6 21.813 2E(4'-O), 1(3-0) 15'-111/2 Pv CM 0.8740 9.02 4.82 150 0.047977 43-21/2 P1 3.272 9 19-6 21.813 T(3'-0) 26-0. Pe 10 19-6 25.086 4E(4'-o), 2T(3'-o) 68'-2%Pv CM 0.8740 12.16 6.50 150 0.083425 39-31/2 Pf 4.864 10 19-6 3.14 25.086 Flow (q) from Route 3 19-0 Pe 4.769 7 8-6 34.719 4E(4'-U), 1(3-0) 583% Pv CM 0.8740 21.00 11.23 150 0.229253 6-0 Pf 2.297 7 8-6 8.84 34.719 Flow (q) from Route 2 4-0 Pe 6 8'-6 37.016 E(4'-o) 10'-0Pv BL 1.1010 21.00 7.08 150 0.074468 4-6Pf 1.303 6 8-6 37.016 13-0 Pe 1.951 5 4'0 40.270 2f, 31r(1'-O), CV(5'-o), 1(5-0) 17-6 Pv UG 1.0250 26.00 10.11 150 0.156619 5-0 Pt 1.206 5 4-0 5.00 40.270 2-8% Pe 1.739 4 -01-0 43.214 E(2'-81/2) 7-8% Pv UG 1.1010 26.00 8.76 150 0.110552 50-0 Pf 6.301 4 -0-0 43.214 7-0 Pe 3 -01-0 49.515 E(7'-o) 57-0 Pv UG 1.0250 26.00 10.11 150 0.156619 6'-0Pf 18.207 3 -01-0 49.515 8-1 Pe 2 -01-0 67.723 3E(2'-81/2), BFP(-12.000), WMV(- 14-1 Pv 4.000) UG 0.9950 26.00 10.73 150 0.180997 20'-0 Pf 4.043 2 -01-0 67.723 2-4 Pe 1.301 1 -3-0 73.066 E(2'-4), S 22-4 iPv 0.00 Hose Allowance At Source 1 26.00 Route ..... CM 0.8740 8.84 4.73 150 0.046260 83-111/2 Pf 5.410 11 19-6 11.98 24.540 Flow (q) from Route : 33'-0 Pe 4.769 7 8-6 34.719 6E(4'-U), C(3'-0), 21(3-0) 116'-11% Pv =. ..... Route 3 ..... CM 0.8740 3.14 1.68 150 0.006827 I 51'-0! Pf 0.546 11 19-6 11.98 24.540 1(3-0), Flow (q) from Route 4 29-0 Pe 10 19-6 25.086 21(3-0), 5E(4'-O) , 80-0 Pv =. ..... Route 4 ..... CM 0.8740 11.98 6.41 150 0.081206 14-7 P1 2.726 9 19-6 9.02 21.813 Flow (q)from Route 1 19,-0 Pe 11 19-6 24.540 4E(4'-O), 1(3-0) 3'- ,Pv Equivalent Pipe Lengths of Valves and Fillings (C'120 only) C Value Multiplier Actual Inside Diameter 487 Value OfC 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0.713 1.16 1.33 1.51 , © M.E.P.CAD, Inc. UjAutoSPRINK 2019 05.1.15.0 3/26/2020 10:57:47AM Page 4 fHydraulic Analysis Job Number: 20-0146 eport Description: i<tI 1 ilL) (1' Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backfiow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DelV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90 Elbow UG Underground Pf Pressure loss due to friction between points EE 45 Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 221W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90 FireLock(TM) Elbow fEE 45 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirE Wirsbo WMV Water Meter Valve Z Cap ,©M.E.P.CAD, Inc. P3 AutoSPRINK 2019 v15.1.15.0 3/26/2020 10:57:47AM Pages 1Hydraulic Summary Job Number: 20-0146 Report Description: RESI 2 HD (1) Job Job Number I Design Engirreer 20-0146 TIM DE KONING Job Name. CHESTNUT AVE RESIDENCE State CertificatioloLicense Number - Address I 1161 CHESTNUTAVE AHJ CARLSBAD FIRE DEPT Address 2 - I Job SitelBudding CARLSBAD, CA 92008 Address 3 Drawing Name 200146—CHESTNUT RES System Remote Area(s) Most Demanding Spninttter Data Occupancy Job outro 4.9 K-Factor 13.00 at 7.039 RESI 2 HD yese Al— Ao Source Density pzeaetAP000ation 0.00 0.050gpm/ft2 512.00ft2 (Actual 142.28ft2) Addinecal Hole Supplier; - Number 01 Sprinklers CatctOated Number Of Nozzles Calculated Cooerage Per Sprtnlden - Node Flow(gpm) 2 0 - 256.00ft2 Hose At Node 5 5.00 AutoPeek Re5At Prnssure For Remote Voca(s) Adlacent To Moot Remote Pzea Total Rosa Streams 5.00 System Flow Demand Total ASter Required (tnolrsiang Hose PJleoannz) 31.64 31.64 Maeunum Pressure Ortalanoe as Loops - 1 0.000 MAdmAXety Ahoos G- 14.25 between nodes 6 and 7 Maoimum Velocity Under Ground 13.05 between nodes l and 2 Volume capacity ctlnulot Pipes Volume capacity of Dry Pipes 64.04ga1 Supplies Hose Flow Static Residual Flow Available Total Demand Required Safety Margin Node : Name (gpm) : (psi) (psi) (gpm) (psi) @ (gpm) (psi) I (psi) 1 . Water Supply 98.000 88.200 500.00 97.941 31.64 68.789 29.152 Contractor Contractor Number I Co-0t Name Contact TIle 20-0146 Name Of Contractor SYMONS FIRE PROTECTION Phone Estenslon Add... t 12155 PAINE PLACE FAX AddreSS 2 POWAYr CA 92064 AddresS 3 Ennarl Web-Sin 1A' © M.E.P.CAD, Inc. dj AutoSPRINK 2019 v15.1.15.0 3/26/2020 10:57:12AM Page 1 Hydraulic Graph Job Number: 20-0146 MC 5 UI5 In Water Supply at Node I 100— Static Pressure 98.000 90 00.00 88.200 - 80--- 70 -3 .64( DD__ 68.7 CL 40— S stem demand curve- 30- 20--- 10- 0 111Lj.L.1.1.1.i.1.L.I.1'uuhuuu liiiliili iilliiili iii iii ii iii liii I I 00 200 300 400 500 600 700 800 900 1000 Water flow, gpm Red rHoidH G71, Water Supply at Node 1 StaIn Pronnure 98.000 Residual: Pressure 88.200 @ 500.00 Aoalable Pressure at 19000 01 Test 97.941 @ 31.64 Sytt00erraM 68,789 @ 31.64 Sv,wrrOerrard InoSuHeg Hose flWoo.rCt CI 68.789 @ 31.64 f, © M.E.P.CAD, Inc. MAutoSPRINK 2019 05.1.15.0 3/26/2020 10:57:14AM Page 2 ' ~~El JiNode Analysis I Job Number: 20-0146 Report Description: RESt 2 HID (1) Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 1 -3-0 S 66.769 31.64 5 4-0 T(5'-O) 29.968 5.00 201 18-0 Spr(-7.749) 4 7.749 13.64 202 18-0 Spr(-7.039) 7.039 13.00 2 -0-0 j WMV(-4.000) 61.676 3 -0-0 E(7-0) 42.502 4 -0-0 E(2-8%) 33.441 6 8-6 E(4-0) 25.994 7 8-6 1(3-0) 22.427 8 18-6 T(3-0) 8.488 10 1 196 T(3-P) 10.411 11 19-6 1(3-0) 8.779 4 12 19-6 , T(3-0) . 8.680 , © M.E.P.CAD, Inc. jRAutoSPRINK 2019 05.1.15.0 3/26/2020 10:57:1 SAM Page 3 Hydraulic Analysis Job Number: 20-0146 Report Description: RESI 2 HD (I) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Route ..... DR 0.8740 13.00 6.95 150 0.094407 931/2 P1 2.291 202 18-0 13.00 4.9 7.039 Sprinkler, 15'-0 Pe -0.650 12 19-6 8.680 3E(4'-O), T(3'-O) 24-3% Pv CM 0.8740 7.00 3.74 150 0.030045 0'-31/2 Pf 0.099 12 19-6 8.680 3-0 Pe 11 19-6 8.779 1(3-0) 33% Pv CM 0.8740 11.56 6.18 150 0.075928 83-111/2 Pf 8.880 11 19-6 4.55 8.779 Flow (q) from Route 3 3Y-0 Pe 4.769 7 8-6 22.427 6E(4'-O), C(3'-O), 2T(3'-O) 116-11% Pv CM 0.8740 26.64 14.25 150 0.355992 6'-OPf 3.567 7 8-6 15.08 22.427 Flow (q) from Route 2 4-0 Pe 6 8-6 25.994 E(4'-O) 10'-0Pv BL 1.1010 26.64 8.98 150 0.115637 4'6:P1 2.024 6 8-6 25.994 13-0 Pe 1.951 5 4'0 29.968 2f, 31r(1'-O), CV(5'-O), 1(5-0) 17'6 Pv UG 1.0250 31.64 12.30 150 0.225204 5-0 Pf 1.734 5 4-0 5.00 29.968 2-8% Pe 1.739 4 -0.-0 33.441 E(2'-81/2) 7-8% Pv UG 1.1010 31.64 10.66 150 0.158963 500 Pf 9.061 4 -0-0 33.441 7-0 Pe 3 -0-0 42.502 E(7'-O) 57-0 Pv UG 1.0250 31.64 12.30 150 0.225204 6-0 Pf 19.174 3 -0-0 42.502 8-1 Pe 2 -01-0 61.676 3E(2'-81/2), BFP(-12.000), WMV(- 14-1 Pv 4.000) UG 0.9950 31.64 13.05 150 0.260257 20-0 Pf 5.813 2 -01-0 61.676 2-4 Pe 1.301 1 -3-0 68.789 E(2'-4), S 22-4 iPv 0.00 Hose Allowance At Source 1 31.64 Route ..... DR 0.8740 13.64 7.29 150 0.103181 2-31/2 P1 0.957 201 18-0 13.64 4.9 7.749 Sprinkler, 7-a Pe -0.217 8 18-6 8.488 E(4'-O), 1(3-0) 9-3% Pv CM 0.8740 9.08 4.86 150 0.048652 34-5 P1 2.356 8 18-6 8.488 j 14-0 -0.434 ,Pe 10 19-6 10.411 2E(4'-O), 21(3-0) 48-5 Pv CM 0.8740 15.08 8.07 150 0.124294 39'-31/2 Pf 7.247 10 19-6 6.00 10.411 Flow (q) from Route 4 19,-aPe 4.769 7 8-6 22.427 4E(4'-O), 1(3-0) ' 58-3% Pv =. ..... Route 3 ..... CM 0.8740 4.55 2.44 150 0.013564 234 P1 0.724 8 18-6 9.08 8.488 Flow (q) from Route 2 30-0 Pe -0.434 11 19-6 8.779 6E(4'-O), 21(3-0) 534 Pv =. ..... Route 4 ..... CM 0.8740 6.00 3.21 150 0.022575 50-81/2 Pf 1.732 12 19-6 7.00 8.680 Flow (q) from Route 1 26-0 Pe 10 19'6 10.411 21(3-0), 5E(4'-O) 76'8% Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) kC Value Multiplier Actual Inside Diameter 4.87 Value Of C 100 130 140 150 ( Schedule 40 Steel Pipe Inside Diameter ) = Factor Multiplying Factor 0.713 1.16 1.33 1.51 , © M.E.P.CAD, Inc. gi AutoSPRINK 2019 v15.1.15.0 3/26/2020 10:57:16AM Page 4 tiIHydrau1ic Analysis Job Number: 20-0146 report uescrlpilon: i<i z FlU (1) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K.Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length — Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt Total pressure at a point in a pipe DeIV Deluge Valve SP Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 90° Elbow UG Underground Pf Pressure loss due to friction between points EE 450 Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 221W Elbow Pv Velocity pressure at a point in a pipe I Flow Device Id Flex Drop FDC Fire Department Connection IE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fIg Flange EN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirE Wirsbo WMV Water Meter Valve Z Cap . © M.E.P.CAD, Inc. AutoSPRINK 2019 05.1.15.0 3/26/2020 10:57:16AM Pages Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 Relimabii Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. C Model RFC76 Model RFC & G5 Cover Plate Sprinkler Model p Nominal K-Factor gpm/psi"2(1/minIbar1 ) Max. Coverage Area ft x ft (mx m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA321 1 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20(6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20 x 20 (6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1131/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor. Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Model RFC30 & RFC30LL Sprinkler Components and Dimensions 2-5/16' (58 mm) Threads Dia. Body Cup Tower 1-3/4 (44 mm) +1- 1/4(6mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) 3/16' (5 mm) ' Pin (extended) Deflector (extended) Model G4/G5 Cover Plate 3-5/16' (84 mm) Dia. Ceiling Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table B above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 2 of 8 January 2020 H 11abil www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plato Load Screw: Bronze Alloy Towers: Copper Alloy Sprinkler Wrench Pins: Stainless Steel Model FC (without wrench-able cap) Deflector: Bronze Alloy Model W3 (with wrench-able cap) Bottom View Cup: Steel Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions L.._ 2-5/16(58 mm) Threads -' I Dia. Body _ I -J--'--j- Cup Tower 1-3/4(44 mm) +1- 1/4(6 mm) Deflector (retracted) Nominal face of fitting to ceiling Fusible Link 1rrtr i r— /16(5mm) Pin (extended) _________________________________ Deflector (extended) 3-5/16" (84 mm) Dia. Ceiling Model G4/G5 Cover Plate Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure" Max. Coverage Area Ordinary Temperature Intermediate Temperature _________________ Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 jllii Page 4 of 8 January 2020 www.reIiablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Model RFC43 & RFC43LL Sprinkler Components and Dimensions I 2-5/16" (58 mm) Threads Dia. Body Cup Tower 1-3/4" (44 mm) +1- 1/4" (6 mm) Deflector Nominal face of fitting to ceiling Fusible Link - 3/16"(5 mm) I II h-•• u_I.••-j_ Pin (extended) -4 II Deflector (extended) mm)Dia. Ceiling Model G4/G5 Cover Plate 3-5/16"(84 Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria r11FT. Minimum Flow and Residual Pressure (') Max. Coverage Area Ordinary Temperature __________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6.1 x6.1) 1 (79) 1 (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table C above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 3 of 8 January 2020 www.reliablesprinkler.com Cover Plate Finishes") Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint>2> Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling(') Ceiling Rating inch (mm) inch (mm) IRFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2to2 1/2to1 135°F RFC30LL G5 (84) (67) (13) (38 to 51) (13t025) (57°C) RFC43, 1350F>2> RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 1650F>3> RFC49LL (74°C) 135°F>2) RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2to2-1/4 1/4to1 (57°C) RFC76 GS (84) (67) (19) (38 to 57) (6 to 25) or 1650F>3> (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC For use with Model RFC Series sprinklers without wrench-able cap installed Model W3 For use with Model RFC Series sprinklers with wrench-able cap installed S Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC3O, RFC3OLL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Z (0 Co Co Co CO -.1 0 0) Bulletin 006 MR; Iiii Page 8 of 8 January 2020 www.reliablesprinkler.com in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Bulletin 135 February 2020 Haim,a bl 0 Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The Fl Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model Fl Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Residential Sprinkler Summary _____ Sprinkler Sprinkler Identification Orientation K-Factor gpm/psi1 Thread Size Installation Options Max. Coverage Area Model Number (SIN) Qpm/bar1') NPTorlSO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14(4.3 x 4.3) F1Res49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res76 CCP R7618 Pendent 7.6(109) 3/4 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) Material Specifications 175°F(79°C) / ( - Thermal Sensor: 3 mm glass bulb Recessed Escutcheons .~T` Sprinkler Frame: Brass Alloy F2 Recessed .. Button: Copper Alloy Sealing Assembly Nickel Alloy with PTFE FV Recessed* . .à Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) - * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res30 Residential Pendent Sprinkler Components and Installation Dimensions !-1/4" (57mm) DIA. 1-15/16' (49mm) DIA. Face of fitting to finished ceiling 1/2" (13mm) +1- 1/4" (6mm) Threads Wrench Flat Sealing Assembly 2-1/4" Glass Bulb (57mm)1 I II I I Load Screw Deflector (32mm) Components Dimensions 1-3/4° (44mm) +1- 1/4(6mm) 2-7/8' (72mm) F2 & FV Recessed Escutcheon Installation Model Fl Res3O Residential Pendent Sprinkler Hydraulic Design Criteria Minimum flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Area Flow Pressure Deflector to ft. x ft.(m x m) gpm (I/mm) psi (bar) Ceiling Distance 12 x 12(3.7 x 3.7) 8(30) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 X 14(4.3 X 4.3) 10(38) 11.0(0.76) 15 x 15(4.6 x 4.6) 12(45) 16.0(1.1) 16x16 (4.9x4.9) 13(49) 18.8(l.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2of 15 February 2020 www.reliablesprinkler.com Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2" NPT or lS07-1 R1/2 Temperature Ratings Nominal K-Factor: 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions iij.IuItw r WIN o3s 2-1/4' (57) F— 1-1/4" (32mm) Dimensions Face of fitting to finished ceiling 5/8" (16mm) +/- 3/8" (9mm) 1-5/8" (41 mm) +1- 3/8" (9mm) Fl Recessed Escutcheon Installation Face of fitting to finished ceiling 1/2" (13mm) +/- 1/4" (6mm) 1-3/4° (44mm) +/- 1/4"(6mm) 2-7/8(72mm) D F2 & FV Recessed Escutcheon Installation Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst1t Maximum Coverage AreaM ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6. 1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15 (57) 9.4(0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20x20(6.1 x6.1) 22(83) 20.2(l.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 February 2020 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1 R1/2 Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed Button: Copper Alloy F2 Recessed VAV Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Wrenches Model W2 Model W4 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res58 Residential Pendent Sprinkler Components and Installation Dimensions 21/40 (57mm) 2-1/4" (57mm) DIA. -r Face of fitting DIA. Face of fitting 115/16 to finished 1 15/16" to finished ceiling ceiling 5/8° (16mm) 1/2° (13mm) FM 3/8"(9mm) (49m +1- 1/4° (6mm) T)D1Hj 4(49 . "mm) 2-1/4° 1-3/4" (44mm) +/- 1-5/8" (41mm) i-/- 1/4" (6mm) (32mm) 2-7/8° (72mm DIA. 2-7/8° (72mm) DlA.— Dimensions Fl Recessed Escutcheon Installation F2 & RI Recessed Escutcheon Installation Model Fl Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16 (4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (25 to 100 mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20 (6.1 x 6. 1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 4of 15 February 2020 ROOM www.reIiablesprinkler.com Model W2 Model W4 Model W4 Wrench Installation Finishes Standard Finishes Special Application Finishes Sprinkler(l) Fl, F2. FV FP, CCP, SWC (Conical) Sprinkler p Fl, F2. FV FP(, CCP, SWC (Conical) Escutcheons Cover Plates Escutcheons Cover Plates (1) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester(2) Polyester Polyester (2) Polyester -- Custom Color Custom Color Custom Color Paint -- Polyester Polyester Electroless Nickel -- -- -- PTFE (2) -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and 'Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1S07-1R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and 1S07-1R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Bulletin 135 February 2020 The Model W4 wrench includes two sets of jaws. One set of I aws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model Wi wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5" (125mm) long extension (not provided) as shown in Figure 13. Page 14 of 15 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2° NPT or 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model W4 (Recessed) 7 Model Fl Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8° (48mm) 3/8°(10mm) +/-1/4°(6mm) +/- 1/4° (6mm) 2-7/8° (73mm) (8mm) I I Top of Deflector Down From 2-1/4° 1-15/16 (57mm) (49mm) Ceiling to be Either 4° to 6" DIA. DIA. (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems() Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1) 30 (114) 26.8(l.85) 4 to 6 inches (1 00 52.4 (3.63) 20 x 20(6.1 x 6.1) 30 (114) 26.8(l.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 18 x 20(5.5 x 6.1) 35(133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 62.9 (4.34) 16 X 22(4.9 X 6.7) 38 (144) 42.9(2.96) 16 x 24(4.9 x 7.3) 42(160) 52.4 (3.61) 14 x 26(4.3 x 7.9) 46 (174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page l3ofls February 2020 Rellabld www.reliablesprinkler.com Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or lS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) W4 (Recessed and Concealed) to C,) c'J 0 F.-0) 0) 0) 0) 0) Z 0 Bulletin 135 Page 15 of 15 February 2020 www.reliabIesprinkler.com Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation LOw water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. Model RFC76 Model RFC & G5 Cover Plate Sprinkler Model Nominal K-Factor gpmlpsP'2 (1/min/bar') Max. Coverage Area ft x ft (m x m) Ustings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA321 1 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20 (6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20 (6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 CULUS: CULUS Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Cover Plate Sealing Assembly: Nickel Alloy with PTFE Model G5 Cover Plate Load Screw: Bronze Alloy Towers: Copper Alloy Deflector. Bronze Alloy Cup: Steel Pins: Stainless Steel Sprinkler Wrench Model W3 (with wrench-able cap) I Bottom View Model FC (without wrench-able cap) Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL onlv Model RF49 & RFC49LL Sprinkler Components and Dimensions 2-5/16(58 mm) Threads -'. I Dia. Body Cup Tower Deflector (retracted) Nominal face of fitting to ceiling 1-3/4(44 mm) +1- 1/4(6 mm) Fusible Link 3/16" (5 mm) Pin (extended) Deflector (extended) Model G4/G5 Cover Plate 3-5/16" (84 mm) Dia. Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure t') Max Coverage Area m Ordinary Temperature Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 ENRON www.reliablesprinkler.com Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Finishes 1' Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Coloaint<2) r P Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling') Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2t02 1/2to1 135°F IRFC30LL G5 (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 1350F'2) RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13 to 25) or 1650F'3) RFC49LL (74°C) 135°F'2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°F'3) (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2° x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (38°C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (660C), respectively. Page 7 of 8 www.reliablesprinkler.com Reliable111111110 R Bulletin 135 February 2020 Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model Fl Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified Residential Sprinkler Summary in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf(4.1 mm/mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1 Res Series sprinklers are listed for use in wet systems only. Sprinkler Sprinkler Identification Orientation K-Factor gpm/psi1' Thread Size Installation Options Max. Coverage Area Model Number (SIN) (lpm!bar112) NPTorlSO7-1 ftxft(mxm) Fl Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) F1Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14(4.3 x 4.3) F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res76 COP R7618 Pendent 7.6(109) 3'4 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) FlRes58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2' NPTor lS07-1R1/2 Temperature Ratings Nominal K-Factor. 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Thermal Sensor 3 mm glass-bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed Button: Copper Alloy F2 Recessed Sealing Assembl Nickel Alloy with PTFE y: RI Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model W4 (Recessed) * Model R/ escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm 2-1/4" (57mm) 1-15/16' to finished ceiling J(49DIA,' ceiling Face of fitting DIA. Face of fitting to finished 5/8' (16mm) _______ +/- 1/4' (6mm) mm) DIA. 1/2' (13mm) _____ ~/ 3/8" (9mm) 2-1/4' 1 5/8 (41mm) +/- 1-3/4" (44mm) +/- 1/4' (6mm) 8" (9mm) _____________ __________________ 1 L132mmi•1 —2-7/8' (72mm) DIA. 2-7/8(72mm) DlA. Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage AreaR ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13(49) 7.0(0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6. 1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7(0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0 (0.83) 18 x 18(5.5 x 5,5) 19(72) 15.0(1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 February 2020 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler(l) Fl, F2. P4 FPM, CCP, SWC (Conical) Sprinkler (1) Fl, F2. P4 FP, CCP, SWC (Conical) Escutcheons Cover Plates ( Escutcheons Cover Plates ) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester (2) White Polyester White Paint Black Polyester (2) Black Polyester Black Paint -- -- Custom Color Custom Color Custom Color Paint - Polyester Polyester Electroless Nickel - PTFE 2 - Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models F1 Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, RI, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install F1 Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and lS07-1111/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and lS07-1R3/4: 14-20 ft-lbs (19-27 N-m) Model W2 Model W4 Model W4 Wrench Installation Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Bulletin 135 February 2020 The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model Wi wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5" (125mm) long extension (not provided) as shown in Figure 13. Page 14 of 15 www.reliablesprinkler.com Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or 1507-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) W4 (Recessed and Concealed) U) C,) c.J C I.- 0) 0) 0) 0) 0) 0 Bulletin 135 Page 15 of 15 February 2020 Bella a www.reliablesprinkler.com Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 130. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. 0 Model RFC76 Model RFC & G5 Cover Plate Sprinkler Model P er e Nominal K-Factor gpm/psi112 min/bar19 Max. Coverage Area ft x ft (mx m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA061 1 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20 x 20 (6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20 x 20(6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20 (6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20 x 20(6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) I Bottom View Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions __ L._ 2-5/16(58 mm) Threads -... I Dia. Body Cup Tower 1-3/4"(44 mm) +/- 1/4"(6 mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Deflector (extended) Pin (extended) F3/16"(5 mm) Model G4/G5 Cover Plate -' - 3-5/16(84 mm) Dia. Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure Max. Coverage Area Ordinary Temperature _________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gprn/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Frne Page 4 of 8 January 2020 www.reliablesprinkIer.com Cover Plate Finishes" rniri Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(') Custom Color Paintt2 Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Min. to Min. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceiling(') Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2t02 1/2to1 135°F RFC30LL G5 (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC43, 135°F2 RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2to2 1/2to1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13t025) or 165°F3 RFC49LL (74°C) 1350F2) RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable PIN 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m)for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Page 7 of 8 www.reliablesprinkler.com Bulletin 135 February 2020 nelmable Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutcheons and conical concealed cover plates Product Description Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model Fl Res Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model F1 Res residential sprinklers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 130. For NFPA 13R and NFPA 130 applications, the design flow and pressure shall not be less than the minimum flow and pressure specified Residential Sprinkler Summary in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model F1 Res Series sprinklers are listed for use in wet systems only. Sprinkler Sprinkler Identification Orientation K-Factor gpm/psi1 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (Ipm/bar"2) NPTorISO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4,9 x 4.9) Fl Res49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) FiRes58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30 CCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14(4.3 x 4.3) F1Res49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res76 CCP R7618 Pendent 7.6(109) 3'4 Conical Concealed or 20x20(6.i x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) Fl Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1R1/2 Temperature Ratings Nominal K-Factor 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass-bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed Button: Copper Alloy F2 Recessed Sealing Assembly: Nickel Alloy with PTFE RI Recessed* Load Screw: Bronze Alloy Sprinkler Wrenches Deflector Bronze Alloy Model W2 Model W4 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) 2-1/4" (57mm) DlA. ceiling (49 ceiling 1-15/16" - to finished 1-15/16" to finished 5/8" (16mm) 1/2' (13mm) 3/8" (9mm) +1- 1/4" (6mm) DIA. —r Face of fitting Face of fitting 21/40 _______ _____________ (57) J (49m 1-3/4" (44mm) +1- 8" (9mm) L__ 5/8 (41mm) +/- 1/4° (6mm) (32mm) 2-7/8" (72mm) DIA. - 2-7/8" (72mm) DIA.—. Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model Fl Res49 Residential Pendent Sprinkler Hydraulic Design Criteria EU1r!II Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 13(49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0 (0.48) 16 x 16 (4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18 (5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6. 1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0 (0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20x20(6.1 x6.1) 22(83) 20.2(l.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpmlsq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 www.reliablesprinkler.com 3 of 15 February 2020 www.reliablesprinkler.com Finishes Standard Finishes Special Application Finishes Sprinkler1 Fl, F2. RI,FPM, COP, SWC (Conical) Sprinkler () Fl, F2. RI, CCP, SWC (Conical) Escutcheons Cover Plates (') Escutcheons Cover Plates 0) Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White Polyester 2 White Polyester White Paint Black Polyester 2) Black Polyester Black Paint -- -- Custom Color Custom Color Custom Color Paint -- Polyester Polyester -- Electroless Nickel -- PTFE (2) - Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, R and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutcheon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model W4 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install 171 Res HSW sprinklers with a ceiling to deflector distance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1S07-1R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and 1S07-1R3/4: 14-20 ft-lbs (19-27 N-m) Model W2 Model W4 Model W4 Wrench Installation Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Bulletin 135 February 2020 The Model W4 wrench includes two sets of jaws. One set of jaws is equivalent to a Model GFR2 wrench and the other set of jaws is equivalent to a Model Wi wrench. Use the smallest of the two sets of jaws that will fit on the sprinkler's wrench flats. The Model W4 wrench is used in conjunction with the installer's nominal 1/2" square drive ratchet and nominal 5' (125mm) long extension (not provided) as shown in Figure 13. Page 14 of 15 www.reliablesprinkler.com Maintenance Reliable Model Fl Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed COP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or 1507-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) W4 (Recessed and Concealed) L) C') c,J C N- 0) 0) 0) 0) 0) Z a: Bulletin 135 iIiiI Page 15 of 15 February 2020 www.reIiablesprinkler.com SPECIFICATION SUBMITTAL SHEET APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contami- nated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. U FT - with integral male 450 flare SAE test fitting ACCESSORIES U Air gap (Model AG) U Repair kit (rubber only) U Thermal expansion tank (Model XT) U Soft seated check valve (Model 40XL) U Shock arrester (Model 1250) U QT-SET Quick Test Fitting Set U Ball valve handle locks U Test Cock Lock (Model TCL24) DIMENSIONS & WEIGHTS (do not include pkg.) A G Relief Valve discharge port: 314"-l" - O.63 sq. in. 1114"-2" - 1.l9 sq. in. FEATURES Sizes: U 3/4" U 1" U I I/4 U 1 1/2" U 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI BI .20.1 OPTIONS (Suffixes can be combined) U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U MS - with integral relief valve monitor switch U P - for reclaimed water systems U S - with bronze "Y" type strainer U BMS - with battery operated monitor switch U FDC - with fire hydrant connection; 2" only U TCU - with test cocks up U V - with union swivel elbows (3/4" & 1") U SE - with street elbows STANDARDS COMPLIANCE ASSE®Listed 1013 IAPMO) Listed UL® Classified (less shut-off valves or with OS&Yvatves) C-UL® Classified CSA® Certified AWWA Compliant C511 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA425-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDAApproved) Buna Nitrile (FDA Approved) Polymers Noryl, NSF Listed Springs Stainless steel, 300 series DIMENSIONS (approximate) WEIGHT MODEL A UNION B LESS BALL LESS WITH SIZE A BALL VALVES VALVES C D E F G BALL BALL VALVES VALVES in. mm in. mm in. mm in. mm in. I mm in. mm in. mm in. I mm in. I mm lbs I kg lbs. kg 3/4 20 1 12 305 133/4 349 73/4 197 21/8 54 3 76 31/2 89 5 127 161/8 410 101 4.5 12 5.5 1 25 13 3301 141/2 368 73/4 197 21/8 54 3 76 32 8 127 173/8 441 W 45 U 6.4 11/4 32 17 432 11813/16 4781 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 229/16 573 22 10 28 12.7 11/2 40 173/8 441 193/8 492 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 241/16 611 22 10 28 12.7 2 50 181/2 470 201/2 5 1015/16 278 23/4 7032895127 63/4w 261/2673221034154 Page 1 of 2 WILKINS a Zum company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V I L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Webslte: http://www.zum.com 5' I 0 50 FLOW RATES (GPM) GRated Flow (Established by approval agencies) 100 150 FLOW CHARACTERISTICS MODEL 975XL 3/4",11",11 1/4",111/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 3.2 6.3 9.5 4 15.8 CL =1137 (I) Cl) lAO 0 IV,) w 69 (0 C,) w 35 a- 250 TYPICAL INSTALLATION Local codes shall govern installation require- ments. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 52 78 105 167 CENTRAL STATION ALARM PROTECTIVE PANEL ENCLOSURE BATTERY MONITOR AIR GAP FITrING 12 MIN. 30 MAX. OPTIONAL WATERMETER\ II I AIR GAP 11 DRAIN 12 MIN 3O MA) DIRECTION OF FLOW CD FLOOR DRAIN DIRECTION OF FLOW c INDOOR INSTALLATION (*shy WI optional BMS) INLET SHUT-OFF OUTDOOR INSTALLATION SPECIFICATIONS The Reduced Pressure Principle Backflow Preventer shall be ASSE® Listed 1013, rated to 180°F and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTm and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a WILKINS Model 975XL. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zum.com Page 2 of 2