Loading...
HomeMy WebLinkAbout2742 STATE ST; 102; FPC2021-0068; PermitPERMIT REPORT (bty of Carlsbad Print Date: 07/30/2021 Permit No: FPC2021-0068 Job Address: 2742 STATE ST, # 102, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Parcel #: 2031811900 Track #: Valuation: $71,192.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Fire Sprinklers Applied: 05/06/2021 Issued: 05/26/2021 DEV2019-0048 Finaled Close Out: 07/30/2021 Inspector: Final Inspection: Project Title: STATE STREET COMMONS Description: PURE TACOS -SPRINKLER T1 (16 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, U STE 14 1341 DISTRIBUTION WAY, U STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1760-602-8561 f I www.carlsbadca.gov A jITAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 21192 PURE TACOS TI 2742 State Street, Suite 102 Carlsbad, CA. 92008 ZURN Model 375DA WILKINS Reduced Pressure Detector Assembly EXISTING Application Designed for installation on water lines In fire protection systems to protect against both backsiphonage and back- pressure of contaminated water into the potable water supply. The Model 375DA shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Unless otherwise noted, applies to sizes 2 1/2" thru 10") ASSE® Listed 1047 UL® Classified AWWA Compliant C550 CSA® Certified B64.4 (4" & 6") C-UL® Classified FM® Approved NYC MEA 218-01-M VOL 3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/4 Model 975XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless steel, 300 series Sensing line Stainless steel, braided hose Features Sizes: 2 1/2", 3", 4", 6", 8", 10" t!uI••I_c - /51Ai4S/ ti Options (Suffixes can be combined) El - with OS & V gate valves (standard) El L - less shut-off valves (flanged body connections) El LM - less water meter El - with remote reading meter El - with gpm meter (standard) El CFM - with cu ft/min meter El G - with groove end gate valves El FIG - with flanged inlet gate connection and grooved outlet gate connection El MS - with Integral Relief Valve Monitor Switch El Pt - with Post Indicator Gate Valve El GF - with flanged inletconnection and grooved outlet connection El BG - with grooved end butterfly valves with integral monitor switches (2 1/2 - 10°) El -509 - with AWWA C509 gate valves Accessories El Air gap (Model AG) El Repair kit (rubber only) El Thermal expansion tank (Model XI) El OS & V Gate valve tamper switch (OSY-40) El QT-SET Quick Test Fitting Set Attention: Relief valve discharge Model 375DA (flange body) and port: Model 375ADA 2 1/2" -6"- 2.75 sq. in. (grooved body) have different lay lengths. 8" - 10" - 3.69 sq. in. Model 3750AG SHOWN BELOW Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI 1316.1 Class 125 Dimensions & Weights (do not include pkg.) DEIENSION (rriEmin'eml WEIGHT MODEL 3751)1k SIZE in, miii A ri I un' A WITH BUrrERFLY VALVES in I1 run', C LESS GATE VALVES in 1::mrn in Mm in. nun E osv OPEr., in nii'u - CS&V CLOSED in. ruin WITH BIFTEWLY VALVES in. 11, mm in, I:rmrn in, Ir'un"i sur- 015 VALVES lbs. 11 Lu GATE VALVES l.LA"IOEO lbs I' CS,SV GATE VALVES G(lC'EG lbr, kg 8jri'ty VALVES GROOVED lbs, I kg 212 31 1787 28 1711 578 4((l ,1'4 1 9 22 73,4 451 5318 39 8.14 210 212 241 83,821: u 34 1& 84 67 7 147[ 32 1813 403 , 14 84 9 22( 101:4 514 17 1301894 43 .112 216 912 241 83/8 l2V 78 35 208 94 60 73 100 3756955 495 8 203 9 221 212 57 81/4461 9 229 8 1 44 3i4l113 X956 59? lO 254 0 /2 267 30 1/2 77 114360 11 8 314 214 J23& 194 88 494 224 468 212 312 10 154: 95E ii 279 51,2 394 37 940 281/2 724 12 1305 153/8 391 83/41421 182 17 tsa 381 110 367 556 1252 10 2 i33/41i 959 11 2 51/239u 558115 ,4F348 ii 1j33r' 33,801 6421.11218 23051111r,41111 528 1180T363 Zurn hdtistrIus, LLC I WIlkins 1747 Commerce Way, peso Ratjkx, CA, USA, 93448 PIt 856-66$-9876, Fax 805-2385786 In Canada I Zurn Industries Urnited 3544 Nashua Drive, Mississauga, Ontario lL4V 112 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Reu J DOWL 1117 Document Nb. BF-3750A Patent No. 5, 913, 331 Product No, Model 375DA Page 1 of 2 MODEL 375DA2 112", 3" & 4" (STANDARD & METRIC) FLOW RATES (lie) 0.0 12.6 25.2 37.9 20 915 10 50.5 138 103 9 69 34 0 200 400 600 FLOW RATES (GPM) MODEL 375DA6"', 8" & 10" (STANDARD & METRIC) FLOW RATES (Vs 0.0 63.1 126.2 189.3 20 9 15 10 It 252.4 800 = •",-:- .' F _________ == == _________ 0 1000 2000 3000 FLOW RATES (GPM) Flow Characteristics G R,,td FI hy apprai gni) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30' (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. PROTECTIVE Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec lOft/sec 15 ft/sec 21/2" 75 112 149 224 3" 115 173 230 346 4' 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 OUTDOOR INSTALLATION INDOOR INSTALLATION Specifications The Reduced Pressure Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1047, and supplied with full port OS & V gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NORVLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Backfiow Prevention Assembly shall boa ZURN WiLKINS Model 375DA. Zurn industries, LLC I Wilkins 1747 Commerce Way, Paso Robles,. CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn industries Umted 3544 Nashua Drive, Mississauga, Ontario L4V 11.2 Ph, 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 Page 1 of 6 NIKING MICROFAST® QUICK l:lI['u'7M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-950 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Pendent Sprinkler VK302 is a small thor- mosensitive glass bulb spray sprinkler available with various finishes and tempera- ture ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. in addition, these coatings have been investigated for installation in corrosive environments and are Listed and Approved as indicated in the Approval Charts. LISTINGS AND APPROVALS ®w5 cULus Listed: Category VNIV FM Approved: Class Series 2000 WARMCk Ccer and R*podtive rm- VdS Approved: Certificates G414009, G414010, G4040095, and 4880045 () LPCB Approved: Certificate 096e/06 CE Certified: Standard EN 12259-1, certificate of constancy of performance 0832-CPR-S0021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) MED Certified: Standard EN 12259-1 EC-certificate of conformity 0832-MED-1003 Refer to Approval Chart 1 and Design Criteria cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G Form No. F033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 2 of 6 r,iII(IIs1G® MICROFASP QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com For example, sprinkler VK302 with a Brass finish and a 155°F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B. Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A %" ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast® Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap - Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_033314 19.02.21 Rev 19.1 Page 3 of 6 N F MICROFASP QUICK l:IIEu'LIv RESPONSE PENDENT I I SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877.384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature Bulb Color U Ordinary 135 °F (57 °C) 100 F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Sprinkler wrench 13655W/B** for recessed pendent sprinklers ** A 112" ratchet is required (not available from Viking) .. * . .#l. .- ___f3y•. •'.-. .#. , l *4 -41111- Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 19.02.21 Rev 19.1 Page 4 of 6 MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page; www,vikinggroupinc.com Approval Chart I (UL) "'"'"' KEY The Viking Microfaste Quick Response :, - Pendent Sprinkler VK302 AiX 4— -ire Maximum 175 PSI (12 Bar) WWP - Base Sprinkler Thread Size Nominal Overall Listings and Approval55 Part SIN ___________ K-Factor Length (Refer also to Design Criteria.) Number' Style NPT BSP U.S.metric' Inches mm cULus' VdS LPCB (E ' 12979 VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y DIZ, CIV Dl 19780 VK302 Pendent 1/2" - 56 80.6 2-1/4 58 -- - - ".. DS 21354 VK302 Pendent - I 15mm 56 80.6 2-1/4 58 -- - -- - -- 06662B VK302 I Pendent 1 1/2" 115 mm1 56 1 80.6 1 2-1/4 58 jA1Z,B1YD2,C2Xj - -- -- - -_18021 IVK3021 Pendent 1 1/2" 1 15 mm 1 56 1 80.6 1 2-1/4 58 A1X,B1Y Al I A1X,B1Y D1X,C1Y7 Dl -- Approved Temperature Ratings Approved Finishes Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175°F 1 - Brass, Chrome, White x - Standard surface-mounted escutcheon or the (79 °C), 200°F (93 °C), 286 OF (141 °C) Polyester5'6, Black Polyes- Viking Micromatic® Model E-1 Recessed Escutcheon B -135 OF (57 °C), 155 OF (68 °C), 175 OF ter5'6 Y - Standard surface-mounted escutcheon or recessed with the Viking Micromatic® (79 °C), and 200 OF (93 °C) 2 - ENT5 Model E-1, E-2, or E-3 Recessed Escutcheon C - 155 OF (68 °C), 175 OF (79 °C), and 3 - Chrome Z - Standard surface-mounted escutcheon 200 OF (93 °C) D - 155 OF (68 "C), 175 OF (79 °C), 200°F (93 °C), 286 OF (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-50021. 8 MED Certified, Standard EN 12259-1, EC-0832-MED-1003. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listinq Requirements: The Viking Microfast® Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Page 5 of 6 II AV= F,1G® MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945.9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) KEY The Viking Microfast® Quick Response I F Pendent Sprinkler VK302 p Maximum 175 PSI (12 Bar) WWP Base Part SIN Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric' Inches mm Number' Style (Refer also to Design Criteria.) 12979 VK302 Pendent 1/2" 1 15 mm 5.6 80.6 2-1/4 1 58 A1Z, B1Y, D2X, C2 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1/2" 15 mm 5.6 80.6 2.1/4 58 A1Z, B1Y Approved Temperature Ratings Approved Escutcheons 135 OF (57 °C), 155 OF (68 "C), 175 OF (79 °C), 200 OF X - Standard surface-mounted escutcheon or the (93 °C), 286 OF (141 °C) Approved Finishes Viking Micromatic® Model E-1 Recessed 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), and 1- Brass, Chrome, White Polyester', Escutcheon 200 OF (93 °C) and Black Polyester4 V - Standard surface-mounted escutcheon or recessed C - 155 OF (68 °C), 175 OF (79 °C), 200 OF (93 °C), 286 2 - ENT-' with the Viking Micromatic® Model E-1 or E-2 OF (141 °C) Recessed Escutcheon D - 155°F (68 °C), 175°F (79 °C), 200 OF (93 °C) Z - Standard surface-mounted escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion proofing for corrosive environments. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 19.02.21 Rev 19.1 Iø- 2-1/8" — ---i: (54 mm) V. •'4. , .,,. ,s1 - 1-1/8" T (29 mm) (51 mm Max tc Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum : 1-1/8" (29 mm) Mm. Page 6 of 6 NIKING® MICROFAST® QUICK 4 l.III[s1UiY.M RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Ceiling Opening Size: 1/2" 2-5/16" (59 mm) minimum (15 mm) 2-1/2" (64 mm) maximum NPT 4. 'f It Installed with a standard 1/8" surface-mounted escutcheon Figure 3: Sprinkler Dimensions with a Standard Escutcheon Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 19.02.21 Rev 19.1 Replaces Form No. F_033314 Rev 18.1.P65 (Removed F-i Escutcheon.) Page 1 of 4 MICROFAST® QUICK I RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 2699459501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The speW cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat. ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note; FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed, 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-3/16" (56 mm) *CULUS Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175/79° = D, 200°/93° = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrench: Standard Wrench: Part No. 21475M/B (available since 2017) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 4 N iI(IFt1G® MICROFAST® QUICK 4 RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The 'liking Microfast® Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 F (57 °C) 100 ¶ (38 °C) Orange Ordinary 155 °F (68 °C) 100 F (38 °C) Red Intermediate 175 ¶ (79 °C) 150 ¶ (65 °C) Yellow Intermediate 200 °F (93 °C) 150 F (65 °C) Green High 286 ¶ (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat - Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F_052114 17.10.05 Rev 17.1 Page 3 of 4 MICROFAST® QUICK %J IF(IF'IG SPRINKLER VK300 (K5.6) l.l:II[iu,yy RESPONSE UPRIGHT The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) "• KEY Microfasf Quick Response Upright Sprinkler VK300 Al ' Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Number' SIN NPT BSP U.S. metric2 inches mm 1 cULus VdS LPCB NYC8 CE 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 -- -- See footnote 7, -- 06661B I VK300 I 1/2' 15 mm I 5.6 I 80.6 I 2-3/16 56 Al, B2 I -- -- ISee footnote 7i - Approved Temperature Ratings A- 135 °F (57 °C) 155°F (68 °C) 175°F (79 °C), 200°F (93 °C), and Approved Finishes 286 -F 11 ,1 6 1 - Brass, Chrome, White Polyester5' , and Black Polyester, ' 6 B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2- ENT 6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. cULus Listed as corrosion resistant. Meets New York City requirements, effective July 1, 2008 8 Accepted for use, City of New York Board of Standards and Appeals, Calendar Number 219-76-SA and City of New York Department of Buildings, MEA 89-92-E, Vol. 16. DESIGN CRITERIA -UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast® Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F052114 17.10.05 Rev 17.1 Page 4 of 4 N II(IIIG® MICROFAST® QUICK lII[.qU'7M RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269.9454501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) KEY Microfast5 Quick Response Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals3 NPT BSP U.S. metric2 Inches mm Number' (Refer also to Design Criteria below.) 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 1 2 QcbEgm Q __ 06661B I VK300 1 1/2" 1 15 mm 5.6 80.6 2-3/16 56 Al, B2 Approved Temperature Ratings Approved Finishes A - 135°F (57 °C), 155°F (68 °C), 175°F (79 °C), 200°F (93 °C), and 286°F (141°C) 1 - Brass, Chrome, White Polyester", and Black B - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F (141°C) 2 - ENT6 Footnotes 1 Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Microfast® Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 17.10.05 Rev 17.1 Replaces Form No. F_052114 Rev 15.2 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone; 269-9459501 Technical: Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsviklngcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing. The sprinklers are designed for dry sys- tems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS ctiLus Listed: Category VNlV WARPaNG Cner acid Qutva FM Approved: Classes 2013 and 2015 WWWP6nicagov NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*) for all listed and approved lengths. * Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Covered by the following U.S. Patents: 8,636,075 and 10,220,231 Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap: Brass LJNS-C31400 or UNS-C31600 Pip Cap Adapter: Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-CIi000 Tube: ERW Hydraulic Steel Tube Support (internal): Stainless Steel UNS-530400 Barrel: Steel Pipe UNS-GI 0260, Electrodeposited Epoxy Base finish Barrel End and Threads: QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Form No. F_031[793 19.10.14 Rev 119,2 Replaces Form F_0311793 Rev. 19,1 (Added ENT; updated FM language.) ,D~ VIKING o72s7Q Sprinkler Wrench I7565V/B** must be used for installing recessed dry sprinklers Step 2: Carefully press the wrench upward and turn slightly to ensur engagement with the sprinkler wrench flats. wwA 1/2 ratchet is required (Not avail- able from Viking.) Step 1: slide t sideways sprinkler .. ._ 19 IM-1 Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikInggroupinc.com Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating, and then the suffix for the length ("A dimension) to sprinkler base part number. Order in a specific length noted as the "A" dimension, The "A" dimension is the distance from the face of the fitting (tee) to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style, 3" to 47" (76.2 mm to 1,194 mm) for the plain barrel style, and 3-1/4" to 47-1/2' (82.5 mm to 1,207 mm) for the adjustable recessed style. Lengths exceeding the standard lengths are available, with no approvals, on a "made-to-order" basis: Recessed Dry Pendent up to 65-1/2' (1,664 mm), Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm), Plain Barrel Dry Pendent up to 65" (1,651 mm). Contact the manufacturer for more information. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, and ENT = JN Temperature Suffix: 155 °F (68 "C) = B, 175 °F (79 "C) = D, 200 "F (93 "C) = E, 286 "F (141 "C) = 0 For example, sprinkler VK176 with a Chrome finish and a 155 "F (68 "C) temperature rating, and "A" length of 10" = Part No. 08383UFB10. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench: Part No. 07297W/B (available since 1991) Wrench for recessed sprinklers: Part No. 07565W/B** (available since 1991) ""A W ratchet is required (not available from Viking). Sprinkler Guard: Chrome, with no listings or approvals, for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: Adjustable Standard Dry Escutcheon: Base Part No. 07741 Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Figure 1: Standard Sprinkler Wrench 07297W/B OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS & MAINTENANC Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Quick Response Dry Pendent Sprink- ler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Vikings current list price schedule or contact Viking directly. FIgure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Form No. F0311793 19.10.14 Rev 19.2 Page 3 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vlkinggroupinc.com fIU wiw:iu Sprinkler Temperature Sprinkler Nominal Maximum Ambient Classification Temperature Rating' Ceiling Temperature 2 Bulb Color Ordinary 155 °F (68 C) 100 'F (38 "C) Red Intermediate 175 'F (79 'C) 150 'F (65 "C) Yellow Intermediate 200 "F (93 'C) 150 'F (65 "C) Green High 286 "F (141 "C) 225 'F (107 "C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, and ENT Corrosion-Resistant Coating'4: White Polyester and ENT in all temperature ratings Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof. Prior to installation, verily through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. " When Installed in some corrosive environments, the Polyester finish may change color. This natural discoloration over time Is not In itself an Indication of corrosion and should not be treated as such. All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. For 'A' Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2' (12.7 mm) between 1-1/2' and 45-1/2' (38.1 mm and 1,156 mm). NOTE1 The deflector will be located approximately 3-7/16' (87.3 mm) below the ceiling. with 1' (25,4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. NOTE To locate the deflector at the minimum distance below the ceiling, with _____________ no downward adjustment JA Minimum ceiling opening N4-7/16. avaRable, order the diameter: 1-3/4' (44.5 mm). (61.9 mm) dry pendent sprinkler Maximum ceiling opening Minimum i' (25,4 mm) shorter 1 diameter: 2-1/4' (57 mm). than the 'A' dimension, 13/16' Ifli NOTE: _r—R20,6 mm) To locate the deflector Finished' Ceiling at the maximum distance 4-7/16' below the ceiling, with 1-1/2'------Sleeve Finish (112.7 mm) no downward adjustment (38.1 mm) matches escutcheon. Maximum available, order the diameter J dry pendent sprinkler 31/16' 1' (25.4 mm) longer (77.8 mm) than the 'A' dimension. Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler Form No. F_031793 19.1014 Rev 19.2 Page 4 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vIkinggroupinc.com Approval Chart I (UL) KEY Quick Response Dry Pendent Sprinklers Maximum 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor2 Listin Order Length Increment s and , Base Part No. SIN Style - NPT BSP U.S. metrics inches mm cULus5 NYC' VdS LPCB CE 08383U VK176 Adjustable Standard I - 56 806 1/2 127 Al A5 Al - - 16457U - 25 mm -- 80.6 1/2" 12.7 Al, AS -- -- - 08385U VK180 Adjustable Recessed 1' -- 5.6 80.6 1/4" 6.35 82, B6 82 164531/ -- 25 mm - 80.6 1/4" 6.35 B2, 86 - -- - - -- 083871/ VK172 Plain Barrel 1" - 5.6 80.6 1/2" 12.7 A3 A4 - - - - 164551/ -- 25 mm - 80.6 1/2" 12.7 A3 -- -- -- Approved Finishes and "A" Dimensions 1 - Chrome or White Polyester7 sprinkler with a Chrome or White Polyester Sleeve and Escutcheon Approved Temperature Ratings with "A" dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) A - 155 'F (68 'C), 175 'F (79°C), 20C 'F (93 "C), 2 - Chrome or White Polyester7 with "A' dimensions 3-1/4" to 47-1/2(82.5 mm to 1,207 mm) and 286'F (141 'C) 3 - Chrome, Brass, White Polyester7, or ENT' with "A' dimensions 3" to 47" (76.2 mm to 1,194 mm) B - 155 'F (68 "C), 175 'F (79°C), and 200 'F 4 - Chrome or Brass with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) (93 'C) 5 - ENT7 sprinkler with an ENT' Sleeve and Escutcheon with "A' dimensions 1-1/2" to 45-1/2' (38.1 mm to 1,156 mm) 6 - EN with "A' dimensions 3-1/4' to 47-1/7'(82.5 mm to 1,207 mm) Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S. and Canada. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 15.. cULus Listed as corrosion resistant DESIGN CRITERIA - _UL A;so 'ever to Approval Chart 1 above I NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees. When selecting other CPVC fittings, contact Viking Technical Services. cULus Listine Reaulrempnts: Standard Dry Pendent Sprinklers, are cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, Designed for use in Light and: Ordinary Hazard occupancies, The sprinkler installation and' obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed, IMPORTANT: Always refer to Bulletin Form No F_091 699 - Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations,, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_031793 119.10.14 Rev 19.2 Minimum ceiling 2-1/8' (54 mm) Maximum ceilin 2-1/2' (63.5 mr Adjustment 5/16' (7.9 mr 5/16' (7.9 ml Minimum: 1' (25.4 mm) Maximum 1-5/8' (42.1 r For "A" Dimension 1. Deter-mine the distance from face of tee to the finished ceiling. Round to nearest 1/4' (6.35 mm) between 3-1/4' (82,5 mm) and 47-1/2' (1,207 mm), ITE: Sprinkler will be recessed approximately 5/16' (7.9 mm) above the finished ceiling with 5/8' (15,8 mm) vertical adjustment available, shed ceiling Dry Pendent Page 5 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Vikinri wAhslta fnr this latst arlitinn tsf this thnItI rIti rsn www uikmnnnr,iii,ii,s,. rrt Approval Chart 2 (FM) ' •' KEY Quick Response Dry Pendent Sprinklers Maximum 175 ISl (12 bar) WWP A1X4 Sprinkler Base SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals' NPT BSP U.S. metric' Inches mm Part No.' (R.f,r1IsQoQ.&enc,it*rtabllow.) 083831.1 111-6 Adjustable Standard 1" -- 5.6 80.6 1/2" 12.7 Al 16457U -- 25 mm -- 80.6 1/2" 12.7 Al 0838511 VK180 Adjustable Recessed 1' - 5,6 80.6 1/4" 6.35 B2 1645311 _________________ — 25 mm - 80.6 1/4" 635 B2 08387U VK172 Plain Barrel 1' - 5,6 80.6 1/2" 12.7 A3 164551.1 - 25 mm -- 80.6 1 1/2" 1 12.7 A3 Approved Temperature Ratings Approved Finishes and '°A'° Dimensions A- 155°F (68 'C), 175°F (79 )' 200 'F (93 °C), - Brass, Chrome, White Polyester, or ENT' sprinkler with a Brass, Chrome, White Polyester, or and 286 "F (141 "C) ENT' Sleeve and Escutcheon with "A" dimensions 1-1/2" to 45-1/2"(38.1 mm to 1,156 mm) "A" Brass, Chrome, White Polyester, or ENT' with dimensions 3-1/4" to 47-1/2"(82.5 mm to 1,207 mm) B -155°F (68 "C), 175°F (79°C), and 200 "F(93 "C) Brass, Chrome, White Polyester, or ENT' with "A" dimensions 3" to 47" (76.2 mm to 1,194 mm) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 K-Factor applies for standard lengths ("A" Dimensions indicated above). Metric K-Factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the FM Approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any ad- ditional approvals. FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above) NOTE: When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-81 tees. When selecting other CPVC fittings, contact Viking Technical Services. FM Aooroval Reoulrements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (includ- ing 2-0) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F 091699- Care and Handling of Sprinklers. Also refer to Form F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 4 )E TFor 'A' Dimension: A 1. Determine the distance from Outside—.. the face of the diameter "' tee to the base 1-5/16' of the sprinkler. (33,4 mm) 2. Round up to the (some as next highest 1/2' 1' (25 mm) (12.7 mm) incre- Schedule ment between 3' 40 pipe). (762 mr)) ond 47' (1,194 mm), Hr (48.3 mm) Figure 5: PlaIn Barrel Dry Pendent Sprinkler Ambient Exposed Barrel Ambient Temperature Temperature 40'F/4'0150'F/10C160'F/16C of Protected Areaw at the Exposed Minimum Barrel Discharge End Lengthw* Face of Tee of the Sprinkler to Top of Ceiling ) ) ) 401: (4'0 0 0 1 0 30'F (-1'C) 1 0 0 0 201:' (-7'C) 4(100) 0 0 10•F (-12'0 8(203) 1(25.4) 0 0'F (-18'0 12 (305) 3(76) 0 -101:' (-23'C) 14 (356) 4(102) 1(25.4) -201: (-29'0 14 (356) 6(152) 3(76) -30'F (-34'0 16 (406)8 (203) 4(102) F (-40C) 18 (457) 8(203)14 (102) -50F (-460 120(508)10(25416 (152) -60'F (-51'C) 120(508)10(25416 (152) (Exposed Barrel) Ceiling 1-1/2' (38.1 mm) diameter L6' (Protected Area) (77.8 mm) Note: To locate the deflector at the minimum distance - below the ceiling. (61.9 mm) with no upward Minimum adjustment avail- able, order the dry pendent sprink- ler 1' (25.4 mm) shorter than the = = 'A' dimension. 4-7/16' (112.7 mm) Maximum J Deflector at maximum distance below ceiling Note: To locate the deflector at the maximum distance below the ceiling, with no downward adjustment avail- able, order the dry pendent sprink- ler 1' (25.4 mm) longer than the 'A' dimension. Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vlkingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vIkinggroupinc.com Install 1 inch NPI threaded Deflector at end of dry pendent sprinkler minimum distance into the 1 inch NPT outlet below ceiling of a malleable iron tee Fitting per ANSI B 16.3 (Class 150) Up to 2' (50.8 mm) or cast iron threaded tee fitting adjustment available. per ANSI 16.4 (Class 125) only. Seal the clearance space around the sprinkler to avoid leak- age of air into the 13/16' protected area and (20.6 mm) consequent formation of condensate around the frame, which could inhibit operation or Sleeve finish cause premature opera- - matches tion. Refer to Figure escutcheon 7 below. If humidity and temp- erature differential causes condensation on the exposed dry sprinkler, consider wrapping the exposed barrel with insulation, foam insulating tape, or equivalent. Minimum ceiling opening diameter: 1-3/4' (44.5 mm) Maximum ceiling opening diameter: 2-1/4' (57 mm). wlhe protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler, For protected area temperatures that occur between the values listed, use the next cooler temperature. *wlhe minimum required barrel length is not the same as the 'A' dimension, Refer to Figures 3-5 for the 'A' dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature In the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) I - Seal / (or equivalent method) fSeat Clearance Insulated 2" ' Opening [j Ceiling Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Replaces Form F 0311793 Rev. 'i9.1 Form No. F_031793 1910.14 Rev 119.2 (Added ENT updated FM language.) no-M I 905~ ~A-P-P-1-®ME I:4NUBk® LL!l SiTiE ElTsILB IN IE Bull Moose Tube'sO Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube* made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tubes° Schedule 10 and Schedule 40 pipes are hot dipped galvanized to. meetASTM A123 standards. All products are stencilled to meet FM & UL specifications. r•ii SCHEDULE 10 PIPE SPECIFICATIONS - -------.--.- -. .- I NOMINAL PIPE O.D. 1.0, WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 157 1.41 lbs/ft 1.820 91 1-1(4 1.660 1.442 9.91 1,81 lbs/ft 2,518 61 1-1/2 1.900 1,682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 •. 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. 1,0, WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE I 1,315 1,049 1-1/4 1.660 1.380 1-1/2 1.900 1.610 2 2.375 2.067 21/2* 2,875 2.468 3* . 3.500 3.068 4* 4.500 4.026 'Ovi1yalb* in Casa Gninde,AZ **Corrosion Resistance Ktio per latest UL Directory Lktirltj PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt, chips grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. * For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call (800) 882-4666 sales@bullrnoosetube corn U 1819 Clarkson Road Owsterfleld,MO Geak1,M0 Kent WA CasaGande.AZ DallaTX Mast" ON 63017 1,00 1.68 lbs/ft 2.055 70 1.00 2.27 lbs/ft 2.918 Si 1.00 2.72 lbs/ft 3.602 44 1.00 3.66 lbs/ft 5.114 30 1.00 5.80 lbs/ft 7.875 30 1.00 738 lbs/ft 10.783 . 19 1.00 10.80 lbs/ft 16.316 19 LE I 4J® L 3jiTi\4hE 16 JIISc1E ISL1 EijjJjE1 Dull Moose Tube'sEddythread40 ADVANTAGES OF BULL MOOSE TUBE° EDDVTHREAO 400 U is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure racing of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM A135 and A795 Type F, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 1111 MIC preventative coating. EDDVTHREAD 400 SPECIFICATIONS NOMINAL PIPE 0.0, I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LBJFT WEIGHT SIZE t 1.295 1.083 1.00 1.461 1.860 70 11/4 1.650 1.418 1.00 2.070 2.754 51 1-tl2 1.900 1.654 1.00 2,547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 Coeen tw" Ratio pr Itt UL D1reioy Lhttn r c®us LISTED ARRM k;]OMFM tFP - PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, Chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A A (f For Additional Information Contact (800) 325-4467 wwwbullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Cbrkson Road ChesterfiektM0 Gerald, MO Kent WA Casa Grande AZ Dallas, TX Maurt0H 63017 ALIIiIE® VUEEBLlG LLTjEBLE' c®us LISTED njO OMFM NFPA ADVANTAGES OF BULL MOOSE TUBE° EDDYLITE° Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL. STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER Ft FILLED SIZE 1 1.315 1.137 0.13 7,47 1.260 1.700 91 1-1/4 1,660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0,12 4,53 1.961 2.965 61 2 2,375 2.177 0.16 4.31 2.617 4.230 37 *Corrosion 116stance Ratio per latest UI. Dirtor' tisting PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ForAdditional Information Contact (800) 325.4467 wwW.buIlrnoosetube.com Or From Canada Call (800) 8824666 sales@bullrnoosetube corn J 1819 Clarkson Road Chesterfield, MO Cncald,MO Kent,WA Casa Gtande,AZ DaIIaiX Masi0H 63017 Bull Moose Tube's° Eddylite' is a lightwall threadable pipe manufactured in NPS through 2". Eddylite° is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness. or standard outside diameter. EddyIite is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. ER I 161C W p ADVANTAGES OF BULL MOOSE TUBE° EDDY FLOW° Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. lii Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD 110 MIC preventative coating. 1 NPS O.D. EDDY FLOWO EDDY FLOW WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (ID) CRR* PER FT. WE SIZE 14/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1,728 3.44 1.844 2.860 61 2 2375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3,361 7,144 19 4 4.500 4.310 1.00 4.968 11.290 19 'Corrosion Rstae Ratio per Iatt lit. Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembI causing leakage. Also, check the manufacturer's instructions for the specific fitting used, Q For Additional Information Contact (800) 325-4467 www.bullmoosetube.com PD,Or From Canada Call (800) 882-4666 sales@builmoosetube.com U 1819 Clarkon Road Chesterfield, MO Gerald, MO KntWA CasaGrandoAZ Dallasi Mastt0lI 63017 7 Bull Moose Tube's° Eddy Elo is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's* larger ID provides an opportunity for downsizing and further cost savings. ULTRA EY® THE SU.EIIP S.B1JIJ~!LER PIPE] Dull MooseTube's° Ultra Eddy* is ADVANTAGES OF BULL MOOSE TUBE° ULTRA EDDY0 U a versatile product that can be • Certified to ASIM Al 35 and A795 Type E Grade & roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule S tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today. Ultra EddyO offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. - -- - - - NPS 00. ULTRA ULTRA EDDY WEIGHT WATER BUNDLE (IN) (IN) EDDY* (ID) CRR PER Ft FILLED WT SIZE I 1.315 -- 1.201 - 2.17 -- .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1,900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 * Prefit is a RegisWreciTudmarkocvktauI Catn iiy orAmtita Corrosion R(mistoce Ratio per latast til 0lraatory Listing c®us LISTED <9> ONFSA NFPA' 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint scale, dirt chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 0 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIImoosetube.com U 1819 Clarkson Road Cheswcfie$d,MO Gerd, MO Kent. WA Casa GrandM DalLaTX Mastat0H 63011 B1ijAT-iIIUE SIZES VitBl!E NPS(IN) 1 1-114 1-112 2 2-112 3 4 c®us LISTED APP1TOVEB E; OMFM NFPA 0.D.in 1315 1.660 1.900 2.375 1.201 1.546 1.786 2.261 ULTRA EDDY° Empty Weight (Ift 0.868 1.107 1.274 1.604 Wa'FiDd Weight (iWft) 1.359 1.920 2.360 1944 C.R.R, 2.17 1,40 1.11 1.00 0.D. On) 1.660 1.900 2.375 2.875 3.500 4.500 I. D. 1,530 1.728 2.203 2.705 3.334 4.310 EmpWWt( 1.222 1.844 2.330 2.809 3.361 4.968 EDDY FLOW° Water- Filled Weight (lb/f 2.019 2.860 1982 5.299 7.146 11.290 C.R.K. 1.98 3.44 2.78 1.66 1.00 1.00 0-D. On) 1315 1.660 1.900 2.375 2.875 3300 4.500 LD.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Empty Weight Oh" 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 Water-Filled Weight Mt 1.820 2,518 3.053 4.223 5.893 7.957 11.796 C.R.R. 15.27 9.91 7.76 6.27 4.92 354 2,50 0D. in 1.315 1.660 1.900 2.375 t.ac) 1.137 1.482 1.712 2.177 EDDYLITE° Empty Weight O&ft) 1.260 1.617 1.967 2.617 Water-Filled Weight (IMt) 1.700 2.364 2.965 4.230 C.R.R. 0.13 0.08 0.12 0.16 üD.in) 1.295 1.650 1.900 2.375 LD.0n 1.083 1.418 1.645 2.123 EDDYTHREAD 400 EmpWet(M 1,461 2.070 2.547 3.308 Water-FilledWeigit0h" 1.860 2.754 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 1 On) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I LD.(jn) 1.049 1,380 1.610 2.067 2.469 3.068 4.026 SCHEDULE 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 WaterFiLtedWeigit(IbIft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 - CPR. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Q Or From Canada Call (800) 882-4666 sales@bullrnoosetube corn a 1819 Clarkson Road Chesterfield, MO Gerak1M0 KntWA Casa Grande AZ DaDaTX Man" 0H 63017 9 ai aEIEKGjjj1U) I 1.1 c®us LISTED APPROVED NFPX -- NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDYD 0.868 91 1,659 1.896 11975 SCHEDULE 10 1.410 91 21695 3,079 3,208 1 EDDYLIIE* 1.260 91 2,408 2,752 2,867 EDDYTHREAD 40* 1.461 70 2,148 2,454 2,557 SCHEDULE 40 1.680 70 2,470 2.822 2,940 ULTRA EDDY° 1.107 61 1,418 1,621 1,688 EDDY FLOW* 1.222 61 1,565 1,789 1,864 SCHEDULE 10 1,810 61 2,319 2,650 2,760 1-1/4 EDDYUTE0 1.617 61 2,071 2,367 2,466 EDDYTHREAD 400 2.070 51 2,217 2,534 2,639 F SCHEDULE40 2.270 51 2,431 2,778 2,894 ULTRA EDDY° 1.274 61 1,632 1,865 1,943 EDDY FLOW° 1,844 61 2,362 2,700 2.812 SCHEDULE 10 2.090 61 2,677 1060 3,187 1-1/2 EDDYLITE° 1,967 61 2,520 2,880 3,000 EDDYTHREAD 401 2.547 44 2,353 2,690 2,802 SCHEDULE40 2.720 44 2,513 2,872 2,992 ULTRA EDDY° 1.604 37 1,246 1,424 1,484 EDDY FLOW0 2.330 37 1,810 2,069 2,155 SCHEDULE 10 2.640 37 2,051 2,344 2,442 2 EDDYUTE9 2.617 37 2,033 2,324 2,421 EDDYTHREAD 400 3.308 30 2,084 2,382 2,481 L SCHEDULE 40 3.660 30 2,306 2,635 2,145 EDDY FLOW- 2.809 1,770 2,022 2,107 2-1i2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 SCHEDULE40* 5.800 3,654 4,176 4,350 EDDY FLOW0 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4,340 19 1,732 1,979 2,062 L SCHEDULE40 7.580 3,024 3,456 3,601 EDDY FLOW0 4,968 1,982 2,265 2,360 4 SCHEDULE 10 5.620 19 2,242 2,563 2,670 SCHEDULE 40* 10.800 4,309 4,925 51130 6 SCHEDULE 10 9.289 10 1,951 2,229 2,322 L 8 SCHEDULE 10 16,940 7 2,490 2,846 2,965 10 OAvF1abe in Casa Grad AL 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales©buflmoosetube.com B!INM LS1ETiI![B1E Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpwj lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 (BC (ASCB0 ) & c'I for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Sze 20 ft 25 ft 30 ft 35 ft 40 ft 025 1 0 50 015 1,00 116 1.50 1.76 200 1 225 250 275 300 1114 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2112 549440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 1 809 648 531 1 4651 381 1 40 1 40 40 1 40 1 37 1 34 1 31 1 29 28 1 26 25 24 4 1 1544 12351 10121 8671 726 1 40 40 40 1 40 1 40 37 34 1 32 30 L 29 2 1 26 Bull Moose Tube EDOYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load PpwJ lbs. Max, Transverse and 4-way Brace Spacing (ft,) According to HLF for the 2006 & 2009 IBC (ASCE7-05 ) & C'p for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft- 30 35 ft. 40 025 1 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 1 1114 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 2 2 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED NO NFP ForAdditional information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call (800) $82-4666 sales@bullmoosetube.com 1819 CIarkon Road Chesterfield, MO Gerald, MO KeitWA Casa GrandAZ baUaTX Masut0H 63017 ii Mechanicali" STYLES 920 AND 920N Victaulic Mechanical-TO Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a "holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe aD. Cross-type connections can be achieved by utilizing two upper housings of the same style and - size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded STYLES 920 AND 920N STYLE 920 CROSS outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- PATENTED ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HOPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 90° angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "1" nitrite Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect- Para__________ Location Approved Date www.vfctauOc.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIc COMPANY. © 2017 VICTAuLIC COMPANY, ALL RIGHTS RESERVED. REVN Jctauiicr 11.021 CARBON STEEL PIPE- HOLE CUT PRODUCTS 11.02 Mechanical-T Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 00 0 r!kp 'p 7rD C _______ 33 .3 d8 W1r1O iJ3r.4j 6I313j '074 I V i -Z-- 2 /2 (a) 2 920N 500 1.50 2.00 2,53 1.61 5,35 2,75 31 50 x 15 3450 38.1 51 64 - 41 136 70 1,5 - V 920½ - 500 1.50 - 1,97 2.53 1.61 5.25 2.75 3.1 -- 20 3450 331 5054 41 136 70 1.5 1 (a) a 500 1.55 1.85 2.53 1.61 5.35 2.75 3.0 W 25 3450 38' 47 54 - 41 136 70 1,4 - 1¼)a)ta 500 - 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3,2 GROOVED OUTLET 32 3450 44.5 52 - 70 76 41 136 76 1.7 - .5 1½ (a) to 90N 500 1,75 2.03 2.75 312 1,61 5.35 3.25 3.6 3.2 40 3450 44.5 52 70 79 41 136 83 1,7 1,5 ________ 2½ x ½ 920N 500 1.50 - 2,21 2.74 - - 1,82 5.64 2.75 3.0 - 65 15 3450 38.1 55 70 46 143 70 1.4 '4(a) 920N 500 1.50 2.18 2.74 1,82 564 2,75 3.0 v 20 , 3453 - 33.1 - 55 70 46 143 70 1,4 - 4 T 1 Ia) §o 920½ 500 150 206 274 1.82 5.64 2.75 2.9 25 3450 38,1 52 70 - 46 143 70 1.4 - 'N 1V4t(a)2 ' 90N 50-3 1.75 2.30 3.00 3.25 1,82 6.29 3,00 3.5 3.2 32 3450 445 , 58 75 53 46 150 76 , 1.7 1,5 FEMALE THREADED OUTLET 1 ½t(a;" 920N , 500 263 2.28 3.00 325 182 5.26 3,25 3.6 3.3 ½ (a) 300 1.50 2.22 2.75 2.25 6.46 3.18 3,9 75,1 x , 9.. 0N 2065 38.1 56 70 - 57 164 81 1.8 • Provides a direct branch connection at 34(e) 920N 300 1,50 2.19 2.75 2.25 6.46 3.18 ' 3.9 any location where a hole can be cut 20 , 2065 38.! 56 70 - 57 164 81 1.8 in the pipe 1 1½ 92015 300 1,50 2137 275 2.25 6.45 3.18 3.8 - 25 2065 38,1 53 70 - 57 , 164 81 1.7 • A pressure responsive gasket provides 1½ ('4 920½ 500 1,75 2.30 3.00 3.31 - 1.92 6.29 300 3,5 3.2 the seal 32 3450 44.5 58 76 34 49 160 76 16 1.5 i/2 )a) 920! - 500 2.00 2.28 ' 3.00 3.31 1.92 ' 6.29 3.25 - 3,5 3.3 • Request Publication 11.03 for 40 3450 50.6 58 75 84 49 160 63 1.6 1.5 Mechanical-T cross assemblies 3 15(a) 920N 500 1,50 2.52 3.05 - 2.28 6.15 2.75 3.4 - 80 15 3450 38.1 64 78 58 156 70 1.6 • Pressure rated up to 500 psi/3450kPa 3/~a( rl 920½ 500 1.50 2.49 3.05 - 2.28 6.15 2.75 3.4 - on steel pipe; also available for use 20 , 3450 38.1 63 , 78 56 , 156 , 70 .6 with HDPE pipe 1½ 920N 500 550 2.28 606 - 2.28 615 2.75 3.3 25 3450 38.1 61 78 58 156 70 1.6 Sizes from 2 x ½/SO x 16mm 1¼(a)t ' 500 1.75 2,55 ' 3,25 3.56 2.28 ' 6,15 ' 3,00 3.8 3.7 92014 through 8x4"/200'xlOOmm 32(b) , 3450 44,5 65 83 90 58 156 76 1.8 , 1.8 1½ (a) to 9205) 500 2.00 2.78 1513 3.56 2.28 6.15 3.25 4,1 3.8 40 )b) , 3450 50.8 71 89 90 58 156 35 1.9 1,8 2 920½ 5130 ' 2.50 2.75 3.50 336 2.28 6.75 ' 3.88 4.9 4.5 50 3450 635 70 89 90 58 72 99 23 2.1 3½ x 2 • 500 2,50 3.00 3.75 2.44 6.72 388 T ' 3.8 90 so 90N 3450 63.5 76 95 62 171 99 J - 1.8 IMPORTANT NOTES. TABLE CONTINUED ON P0.3 Style 920 and Style 920N housings cannot be center of run to engaged pipe end, female threaded outlet only (dimensions aoproxirrate). mated to one another 6 Available with grooved or female threaded outlet. Specify choice on order, to achieve cross connections. t Center of run to end of fitting. 8 Female threaded outlets are available to NFl and BSPT specifications. @ See sage 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order. § Vds approved for fire protection services P LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company, wwwvrctaulic.corn v)cTAuuc IS REGISTERED TRADEMARK OF viclAuLic COMPANY. © 2017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. X, Amt-auticr 1102.2 REVJI DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 1103 for Mechanical-I crass assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 15 mm through 8 x 4/200 x 100mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N 0 0 f3 'ram, roas s43Dj 8'2 D8cs mam' 0. 4r, çjr,2 ero TABLE CONTINUED FROM PAGE 2 4 / VI a V 5001 1510 3.03 3.56 269 701 275 3,7 100 V 3450 38.1 77 90 68 178 70 1.8 - 9)99) 500 .50 3.00 3.56 2.69 7.01 2.75 3,7 20 3450 38.1 76 90 - 68 178 70 1.8 - 9VON 500 1,50 2.88 3.56 2.69 7,01 2.75 3.6 25 3450 381 70 90 68 178 70 1.8 - 9209) 500 - 1.75 3.08 3.78 4.00 269 V 731 300 4,3 0.6 32(b) 345044.5 78 9610268 178 76 1,9 1.8 i½ (3) to 9209) 500 2.00 3.28 4.00 4.00 2.69 7.01 3.25 4,2 3.9 40 (b) 3450 50.8 83 102 102 68 178 83 2.0 1.9 2(a)ts 9209) 500 2.50 3.25 4.00 4,002.69 7,01 3,889.04,8 50 3450 63.5 83 102 102 68 178 99 2,3 2.1 2,Y,a)r 920 500 2.75 288 4,00 4,00 2.69 7,34 4.635.85,0 65 3450 69.9 , , 73 102 102 68 186 118 2.6 2.3 76' mm , 920 500 2.75 2.88 ' 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 - 102 68 186 118 - 2.9 )a)1V 920 500 350 3.3 450 .12 269 724 512 8A 64 80 3450 88.9 84 114 135 68 196 130 3,8 2,9 1080 154(a)a ' 9209) 500 1,75 3.08 3,78 V 2,63 7,64 3,05 V - ' 32 3450 44.5 78 96"" 67 194 78 2,3 I ½ (ale 9)99) 500 2.00 3.28 4.00 2.63 7.64 3.25 5,0 V 3450 50,8 83 102 , , 67 194 83 2,3 - 2(a) 9209) 500 2,50 3,25 ' 4,00 ' 2.63 - 764 4.00 4.0 50 3450 615 , 83 , 102 67 194 102 1,9 - 76 mm 920 500 275 288 403 401' 263 7,64 429 80 78 3450 69.9 - 73 102 102 67 194 109 16 3,5 3(a) 2 500 3,503.31 4,50 4.50 2.63 7.634.886.86,5 80 90 3450 500 88.9 20 84 43 114 475 114 475 - 67 316 194 9/0 124 69 3,1 74 3.0 76 1½'a)4 I, 125 40 2 3450 50.8 '02 121 121 80 246 94 3,4 3,4 2(a) 6 20 500 2.50 4,00 4,75 475 3,16 970 4.38 8.2 8,0 50 , 3450 63.5 132 121 121 80 246 111 3.7 3.6 2½(a)t - 920 500 2.75 3.63 4.75 4.75 3.16 4,638.3 7.9 65 3450 69.9 92 121 121 80 246 118 3.8 3.6 500 2.75 V 3.75 V 4,75 3,16 9.70 4.63 8.0 76.mmr920345069,995 121 80 246 1)8 3.6 3 fa) t 920 500 3,50 3,81 5.00 4,63 3.16 ' 9,70 5.31 8,4 8.8 80 9209) 3450 500 , 88.9 , 2.50 97 3.75 127 4.50 118 , 80 3.17 246 8.00 135 3.88 3.8 8.0 4.0 1330 x 2 50 3450 63.5 95 114 - 8) 203 99 5.6 - 920 500 350381500 3.009.465,31 3.0 30 345.3 88.9 97 127 76 240 135 3.6 - TABLE CONTINUED ON PG. 4 Center of run to engaged pipe end, female threaded outlet only (dimensions 8pproximate). 6 Available with grooved or female threaded outlet, Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to MIT and BSPT specifications, See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe theaded outlet is available as listed Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2½" BSPT clearly on order, § Yds approved for fire protection services o LPCB approved for fire protection services' 0 Approved for use in China by Tianjin Approvals Company, www.vtctauBc.com ictsuhd VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 vIcTAuLIc COMPANY. ALL RIGHTS RESERVED. REV-1N 11,023 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½750 x 115mm through 8x 47200x 100mm IMPORTANT NOTES; Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections, Imamp ON W"Mm 0 iR ill ( I3 Ii28;r EErA8 5ae.ira , s TABLE CONTINUED FROM PAGE 3 92CIN 500 230 373 450 3.30 8.2' '2 70 40 350 50's 96 1. - 54 239 83 2 - 2 920' 500 230 37 4.50 333 823 388 90 SO 923 340 500 83 175 95 44 4 53 513 31. 379 209 9 99 '2' 41 51 - 1.3 6 14(a) 150 32 b, 1. 340 445 112 130 13096 232 83 23 22 920.11 530 - 203 443 5' 5 3 379 9 5 - 32 54 5 40 1b) - 3450 508 12 30 130 , 96 232 83 24 - 23 500 50 1.33 53 53 79 9'5 388 60 56 0 9237 ' 340 63s 1(1 30 375 96 232 99 27 2 1/2 920 530 2,75 1.3 5 5. 2 363 1351 463 8 75 65 3450 63.9 110 30 133 94 267 118 3.8 34 761 rnmo 90 500 415 52 369 1051 463 84 34150 599 05 - '2 94 - 267 118 38 920 500 330 431 550 5J 3 3.69 1351 - 5.3 9,9 84 80 3450 889 '0 140 130 94 557 13 - 45 .,3 ' ' 9O 500 43 38 7 533 - 369 105 2' 101 10' 00 9406 5450 03 1143 2 0 97 44 1 6 5 13 1 7 94 363 267 9413 - 1, 325 6 78 6 so / 40 3450 508 112 130 92 239 - 33 35 2's ON 5530 50 438 13 36 940 388 81 50 - 3450 635 111 130 92 239 99 36 751-nm 920 03 27- 4.38 13 353 9453 465 9,0 5 - 3430 6 9 111 143 ls 92 239 8 45 4 - 923 500 30 4.31 550 313 363 91.3 31 - 81 145 80 340 689 0 140 30 92 239 135 37 6,4 lOSOm I 922 500 450 44 538 35 940 5(2 100 1450 43 113 - 37 92 45 920 500 1.50 33 575 363 940 625 '83 00 3450 1143 9683 146 92 239 159 85 - TABLE CONTINUED ON PG, S Center of run to engaged pIpe end, female threaded out et only (dimensions approximate). t Available witS grooved or female threaded outlet, Specify choice on order. * Center of run to end of Fitting. 3 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed, Specify "BSPT' clearly on order. (b)For 76.1 mm trrreaded outlet, specify 2½'BSPT clearly on order. 8 Vds approved for f:re protection services o -PCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.vtctaullc.com VICTAULIC IS REGISTERED TRADEMARK OF VIC1AUC COMPANY. © 2017 VICTAI.JLIC COMPANY. ALL RIGHTS RESERVED, 1L024 j'(ctauIic CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 5ari C '1i'9 1 Gicx. Irg3 :r. I922 5c8m 'I9 a rr_ :-,I 1651 X25 920N - TABLE CONTINUED FROM PAGE 4 25 8.0 - 6--~ w 1¼ a 920N 500 1.75 4.43 5.13 3.79 9.34 3.25 84 - 32 3450 9 ON 445 13 30 - 96 237 83 38 /(a)i'a 50j 200 441 513 513 379 934 325 9 54 40 2455 08 112 130 130 96 227 83 38 24 GROOVED OUTLET 7 fa) t 920N Soo 2.50 4.38 5.13 5.13 3.79 9.34 3.58 8.5 - 6.0 50 3450 63.5 iii 130 130 96 237 99 39 2.7 500 2.75 4,01 5.13 5.21 3.63 10.51 4.63 8.6 7.6 76j mm 920 3450 69.9 110 130 132 92 267 118 39 3.4 4 Y I4-Z-4 3(a) 'f a 500 3.50 4,31 5.50 5.13 3.63 10.51 5,31 10.2 8.4 80 920 3450 889 110 140 130 92 267 135 4,5 3.8 v 4(a)to 920 500 4.50 3515.75 5.38 3.53 10.51 5.2510.58,4 100 3453 114,3 97 146 137 92 267 159 48 3,8 - '8 2(a)t 920 5002.75 5446195.25 4.8112.424,50i.6 11.6 9 200X50 345069,9138157 159 122 316 .1.14:3,,5 1?29 920 500 275 507 6.19 619 81 242 450 6 116 65 3450 59.9 129 157 157 122 316 114 5,3 5.3 FEMAEThREADEDOUTLET ' 500 - 2.75 - 5,25 6,25 ' 481 ' 12.42 4.56 11.6 mm Z 3450 69,9 133 - 159 122 315 116 - 5.3 3a2 500 350 ii 6,50 650 481 242 31 126 115 Provides a direct branch connection at , 920 3450 88.9 135 165 165 , 122 315 135 5,7 5.3 any location where a hole can be cut 4(a) t 920 500 4.50 ' 4.81 6.75 ' 6.38 481 1242 ' 6.25 15.3 12.5 in the pipe 100 3450 114.3 122 171 152 122 316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). A pressure responsive gasket provides t Available with grooved or female threaded outlet. Specify choice on order, the seal Center of run to end of fitting, Request Publication 11.03 for # Female threaded outlets are available to NPI and BSPT specifications. Mechanical-T cross assemblies @ See page 7 for Fire Protection approvals and pressure ratings.' Pressure rated up to 500psi/3450 kPa (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. on steel pipe; also available for use (b)For 751 mm threaded outlet, specify 21/2" BSPT clearly on order. with HDPE pipe § Vds approved for fire protection services a LPCB approved for fire protection services Sizes from 2 x ½750 x 15 mm 0 Approved for use in China by Tianjin Approvals Company. through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 9201\1 housings cannot be mated to each other to achieve cross connections, www.victauUccam jctauiic vlcTAuuc IS REGISTERED TRADEMARK OF VICTAULIc COMPANY, 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED REVJ4 I1,02.5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T0 Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 MechanicalTa fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. C, and Ky Values Values for flow of water at +60F/+16°C are shown in the table below. Formulas for Cv ,K, Values: AP =Q2 Where: p = Where: V ç Q=Flow(GPM) Q= Flow (m3/hr) f \ Q = C x tsP = Pressure Drop (psi) C = Flow Coefficient V AP = Pressure Drop (Bar) [_J J Q = K, x K = Flow Coefficient Exaggerated for clarity oullet Size Schedule OUTLET tSIZE irL8L 40 Ca,bon Steel Pipe (per UL 213, sec. 161 __________________________ _____________ 11Ai /2 0.840 2 11 15 213 - . 9.4 IK 1050 4 .16 20 26.7 13,7 131S 3- 8 21 1¼ 11.660 6 so 48 32 42,7 429 411 1½ 1.900 -. ' 53 .. 53 40 98.3 454 45.4 2 2.375 112 104 50 603 ' 96 89. 2½ 2.875 ' - -o 2 7 / '_ 2 150 65 73.0 02 128.5 3.000 76,1 mm . 6 161 76.1 - 38/ 3.500 14 15 249 237 80 88.9 213.4 203.1 4.500 20 22 42 1 401 100 114,3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165ini4.2mm. 1', FireLock Innovative Groove System (IGS) outlet www.vtctauflc.com %J(ct8uIic! vicTAuLic IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. © 2017 vICTAULIC COMPANY. ALL RIGHTS RESERVED, 11.026 REV" CARBON STEEL PIPE. HOLE CUT PRODUCTS 11.02 Mechanical-r Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies, Contact Victaulic for performance on other pipe and the latest listings and approvals. LC rrt!Si:1 I- !A2& 21/2-6 2.875 - 6.625 All 10,40 400 203 400 290 232 362 65- 150 730- 168.3 2.875 - 4.500 All - DF 2755 300 2755 300 2755 300 1999 290 1599 232 2496 362 21/2 -4 65-100 730- 114,3 2.375 - 4,500 All 5F 2065 300 2065 300 2065 300 1999 290 1599 232 2496 362 21/2-4 65-100 73.0-114.3 6.625 3,4 10 2065 300 2065 300 2065 250 1999 290 1599 232 2496 362 6 150 168,3 6.625 34 3043 2065 303 2065 330 1724 300 1999 290 1599 232 2496 362 6 150 168.3 ' 6.625 ' 2/2 ' ' 10,40 2065 400 2365 - - 2065 -. - 1999 - 1599 145 2496 - 8 200 219.1 -- , , 2755 . 1000 - 8 8,625 34 10 303 250 145 - 200 219,1 8.625 34 30,40 2065 300 - 1724 ' 300 - 000 145 - 8 200 219,1 '' 2065 2065 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe, DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC.TAP II HOLE CUTTING TOOL FOR 4 . 87100- 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-I unit, which is a combination of the Style 920 Mechanical-I and Series 726. Vic-Ball Valve. The Vic-lap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450kPa. The Style 931 Vic-lap II Mechanical-I unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 67150mm and 8"/200 mm diameter pipe. The Style 931 comes with a2 ½"/65 mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCI) in accordance with safety codes. For more information, refer to publication 24.01. www.victautfc.com \JttauhC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vlc'rAuuc COMPANY. ALL RIGHTS RESERVED. REVJI 11,027 Mechanical-10 STYLES 920 AND 920N INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. .4. For complete contact information, visit www.victaulic.com \jf'taubc! 11.02 1480 REM N UPDATED U/2017 vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11,02 L STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1715, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Approved www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED, REVG 't4tauIucr 10.52.1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock0 Outleti' STYLE 922 DIMENSIONS V 11 1 , T 3/~ 13/16 1.28 1.83 1.10 3.87 2.56 1.1 j - - - - - - 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 W 1 1/6 1.52 2.18 1.10 387 256 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 0.54 11/2 x ½ 13/,6 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 0.54 3/~ 13A6 1.40 1.95 1.22 - 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 1036 65.0 0.54 1 1 3/16 1.64 - 2.30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 - 103.6 65.0 0.59 2 x ½ 1 3/16 1.66 2.19 1.46 4.60 2.56 1.3 50 15 30.2 42.2 55.6 371 116.8 65.0 0.59 3/4 1 3A6 1,64 - 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 1 3A6 1.88 2.54 1.46 4.60 2.56 - 1.5 25 30.2 47.8 64.5 371 116.8 65.0 0.68 21/2 x ½ 1 3A6 1.91 - 2.44 1.71 5.40 2.56 1.6 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3/~ 1 3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 073 1 1 3A6 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 1 3A6 1.91 2.44 ' 1.71 5.50 ' 2.56 1.6 76.1 mm X 15 30.2 - 48.5 62.0 43.4 139.7 65.0 0.73 3/4 13/,6 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 1 1/I6 2.13 2.79 1.71 ' 5.50 2.56 - 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com - VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. •CtUIiC 10,522 REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock0 OutfetT STYLE 922 PERFORMANCE Schedule 40 Steel Pipe (per I.I. Run Size x Outlet Size 213, Section 16) (C=120)-, FT 1¼ 1 8.5 32 25 2.6 1½ 1 8.5 40 25 2.6 2 1 8.5 50 25 2.6 2½ x 1 8.5 65 25 2.6 76.1 mm X 1 25 8.5 26 Hazen-Williams coefficient of friction is 120 www.victaulic.com \,/(tauIic VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED, REV-(; 1O52_3 FireLock' STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 jctauliC VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 vICTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 lum=m MUMItITZIATIMMrIi.Uu ' SM1TH,X00PER-' Specifications branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP Ductile iron castings conform to ASTM A536 c QO)L us LISTED Fitting dimensions conform to ASME B 16,3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME 131.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 500 150 200 480 250 460 300 440 350 420 400 400 450 380 500 360 550 340 - 600 320 650 300 c®US <e> APPROVED LISTED Fig. 35E 3-90° Elbow Size in Part Number in Packing WéihE lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 --0-.8- 1-1/2 35E3014 1.94 18 36 1.1 2 35E 3020 2.25 20 , 1.8 10 2-1/2 35E 3024 2.70 4 8 3.2 Size in Pa ii Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 lx 1/2 1x3/4 1-1/4 x1/2 1-1/4x 3/4 1-1!4x1 1-1/2 x 1/2 1-1/2x3/4 1-1/2x1 1-1/2x1-1/4 Tx 1/2 35RE3006004 35RE3010004 35RE3010006 35RE3012004 35RE3012006 1.20 1.26 1.38 1.34 1.22 1.36 1,45 80 70 ' 50 160 140 100 70 70 60 60 , 50 40 36 0,3 0.4 0.4 1.53 1.63 35 35 30 30 25 20 18 18 0.5 0.6 0.7 0.6 0.7 0.8 1.45 35RE3012010 35RE3014004 1.58 1.52 1.52 1.65 1.67 - 1.75 353014606 358E3014010 35RE3014012 -35 20004- 35RE3020006 35RE3020010 1.75 1.80 1.88 1.97 1.97 1.82 1.60 1.60 1.0 36 1.0 2x3/4 2x1 2x1-1/4 2x1-1/2 18 16 12 10 36 32 24 20 TO 1.2 1.3 1.73 1.90 2.02 2.10 35RE3020012 35RE3020014 2.02 2.16 2.39 2.16 1.5 2-112x1-1/2 2-1/2 x 2 35RE3024014 35RE3024020 2.51 2.60 ---6 -H 12 2.2 6 2.5 Fig. 35F3 - 45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 - 35F 3004 0.88 150 300 0.2 - 35F 3006 0.98 80 160 80 0.3 0.5 1 35F 3010 1.13 40 1-1/4 1-1/2 - '• 35F3012 1.29 25 50 40 - 0.7 - 35F 3014 1.44 20 1.0 2 2-1/2 35F 3020 35F3024 1 69 10 20 1.6 1.95 4 8 2.7 Fig. 35RE3 - 900 Reducing Elbow Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 35T 3006 - 3513010 1.31 30 60 0. 1 1.50 25 50 0.7 1-1L4 1-1/2 3513012 3513014 175 10 20 1.1 194 10 20 1.5 35T 3020 - 2.25 6 12 2.4 2-1/2 351 3024 2.70 4 8 4.3 lii SM1THCOOPER iNTERNtVfl()NAL 9 TOLL FREE 1-80()-766-0076 • FAX (323)890-4456 0 www.srnihcopercQm c®US Fig. 35RT3 - Reducing Tee LISTED Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 1x1/2 lx1/2x1 1-x- 3/4 1x314x3/4 1x3/4x1 1-1/4x1/2 1-1/4x1/2x1-l/4 1-1/4x3/4 1-1/4x3/4x1-1/4 1-114x1 1-1/4 xlxl/2 1-1/4x 1 x3/4 1-1/4xlxl 1-1/4x11-1/4 1-1/2x1/2 1-1/2x1/2x1-1/4 35RT3006004 35RT3010004 35R13010004010 35R13010006 35R13010006006 120 1.26 1.50 1.38 1.38 1.50 1.34 1.75 1.45 120 1.26 1.36 1.38 1.31 145 1.34 1.53 1.45 1.62 1.58 1.26 1.38 1,50 1.69 1.22 1.36 1.50 1.45 1.45 1.50 1.53 1.75 1.62 1.75 1.67 1.53 1.63 1.69 1.75 1.66 1.88 60 30 30 25 35 25 20 25 15 20 15 25 20 20 15 120 60 60 50 70 50 40 , 50 30 0.4 0.6 0.6 0.6 0.6 0.7 0.8 0.9 0.9 1.0 1.0 0.7 0.8 35R13010006010 35R13012004 35RT3012004012 35RT3012006 35R13012006012 35RT3012010 1.75 1.58 40 30 35RT3012010004 35813012010006 1.34 1.45 1.58 1.75 50 40 40 30 32 35RT3012010010 35873012010012 0.9 1.0 1.0 1.1 358T3014004 35R13014004012 1,41 1.81 1.41 1.56 16 24 48 24 32 1-1/2x1/2x1-1/2 1-1/2x3/4 1-1/2x3/4x1-1/4 1-1/2x3/4x1-1/2 1-1/2x1 1-1/2x1x1/2 1-1/2x 1 x3/4 1-1/2x1x1 1-1/2 x 1 x 1-1/4 1-1/2x1x1-1/2 35R13014004014 35873014006 794 1.52 1.66 1.52 1.94 1.75 1.88 1.94 1.80 1.69 12 16 20 18 12 20 16 16 1.2 1.1 358T3014006012 358T3014006014 358T3014010 1.94 1.94 1.66 1.75 40 36 24 1.1 1.2 1.65 1.65 1.25 1.2 0.8 35RT3014010004 1.44 40 35R73014010006 35R13014010010 1.50 1.44 1.50 1.75 1.80 32 32 0.9 1.0 1.65 35813014010012 35813014010014 1.82 1.94 1.67 1.80 1,88 1.94 12 12 24 24 1.2 1.3 1-1/2x1-1/4 1-1/2x.1-1/4x1/2 358T3014012 35R13014012004 1.82 1.82 1.88 1.66 12 16 24 32 1.4 0.9 1.41 1.34 1-1/2x l-1/4x314 1-1/2x 1-1/4x1 35R13014012006 358T3014012010 -152--1.45 1.65 1.58 1.75 1.80 1.88 16 16 32 32 28 28 1.0 - 1.1 1-1/2x1-1/4x1-1/4 1-1/2x1-1/4x1-1/2 35R13014012012 358T3014012014 1.82 1.75 14 14 1.3 1.4 1.94 1.88 1.94 2x1/2 35RT3020004 -T49-7-4-9 -T-88 10 20 20 6 35R13020006 1.60 Ej:l.5 2x 3/4 1.60 1.97 10 2x1 2 x 1 x 2 35RT3020010 1.73 1.73 2.02 8 16 17 35R13020010020 2.25 2.02 2.25 8 16 1.9 2x1-114 2x11I4x2 358T3020012 35RT3020012020 1.90 1.90 2.10 2.25 8 8 16 1.9 2.0 2.25 2.10 16 2x1-1/2 35813020014 2.02 2.02 2.16 8 10 16 2.1 2x1-1/2x1/2 35813020014004 1.49 1.41 1.88 20 1.3 2x1-112x3/4 35R13020014006 1.60 1.52 1.97 20 1.4 2x1-1/2x1 35R13020014010 1.73 1.65 2.02 8 16 16 1.5 2x1-1/2x1-1/4 35R13020014012 1.90 1.82 2.10 8 1.7 2x 1-1/2x 1-1/2 35813020014014 2.02 1.94 2.16 8. 16 1.8 II Fig. 35BT3 - Bull Head Tee Size in Part Number 'A in B in C in Packing Weight lb Inner Master 314x1 35813006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35813010012 1.67 1.67 1.80 1.58 20 40 0.9 1 x 1-1/2 35813010014 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 35813012010014 1.88 1.80 1.82 15 30 ' 1.2 1-1/4x 11/2 1-1/2x' ' 35B13012014 1.88. 1.88 1.82 15 30 1.3 1-1/4 x2 ' 35BT3012020 2.10 2.10 1.90 10 20 1.6 1-1/2x1-1/4x2 358T3014012020 2.16 2.10 2.02 10 20 1.8 35BT3014020 2.16 2.16 2.02 8 16 1.8 SMII'H-COOPER INTERNATIONAL® • TOLL FREE I-800-7660076 0 FAX (32.' 890-4456 0 wwsrnithcooper.com 112 c®us APPROWD Fig. 35CP3 - Straight Coupling with Ribs USTED Size -- in Part Numb Number A in Pi king Weight lb Inner Master 1/2 35CP3004 1,38 200 400 0.1 3/4 35CP3006 1.63 - - 100 200 -6.2--- 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 70 0.5 35 1-1/2 35CP3014 2.19 50 0.7 25 2 35CP3020 2.62 15 30 1.2 2-1/2 35CP3024 3.00 9 18 2.2 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1x3/4 1-1/4x1 1-1/2x1 1-1/2 x 1-1/4 2x1 2x1-1/4 35H63010004 35H63010006 35H93012010 35H83014010 35H83014012 35HB3020010 35H83020012 35H83020014 1.06 180 360 360 180 0.2 0.1 0.2 1.06 1.19 180 90 ' 1.25 1.25 75 150 150 0.4 0.3 0.6 75 1.38 1.38 40 40 80 80 0.6 2x1-1i 1.38 40 80 0.6 Fig. 35SP3 - Square Head Plug [ 'Size in Part Number - A in Pickij Weight lb Inner Master 1/2 E 3/4 1 35SP3004 35SF3006 35SP3010 0.94 600 1200 0.07 0.1 0.1 0.3 0.4 1.12 350 700 1.25 200 400 200 160 L 1-1/4 35SP3012 1.37 100 80 1-1/2 35SP3014 1.44 - - 2 35SP3020 1.50 45 90 0.6 _JA Fig. 35RC3 - Hex Reducing Coupling Size - in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1x3/4 ' 1-1/4 x3/4 2x 1 (not hex) 35RC3010004 35RC3010006 35RC3012006 35RC3020010 j 1.69 80 160 120 80 40 0.3 0.4 0.6 1.0 1.69 2.06 60 40 2.81 20 Fig. 35HB3 - Hex Bushing Fig. 35U 3- Union with Brass Seat Size in Part Number ______________ A in Packing Weight lb Inner Master 1 35U3010 2.19 20 40 30 20 12 1.0 1.2 1.7 2.4 7114 1-1/2 35U 3012 2.50 15 35U3014 2.62 10 2 35_U_30_0 3.12 6 113 SMiTH-COOPER INTERNATIONAL® 0 TOLL FREE 1-800-766-0076 • FAX (3Z3)890-4456 • www.srnithcooper.com A A [ Size in Part Number A in Packing - Weight lb Inner Master 1/2 r 1 35C 3004 0.87 300 600 01 35C 3006 3563010 0.97 - 200 400 0.1 1.16 110 - 220 140 100 0.2 1-1/4 1-1/2 35C3012 35C 3014 1.28 70 0.4 0.5 133 50 25 2 2-1/2 35C Mn 35C3024 1.70 r-18 50 36 0.8 1,6 Fig. 35BC3 - Beam Clamp C@US <e> APPROVED LISTED Sibe in Part Number A in Packing Weight lb Inner Master 1 35X 3010 150 20 40 0.9 1-1/4 35X 3012 1.75 12 24 - 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 2.25 6 12 2,8 Fig. 3513— Cross Fig. 35SX3 - Reducing Cross [SIze in Part Number I A in B in Packing Weight I lb Inner I Master 1-1/4x1 1-1/2x1 2 x 1 35RX3012010 1.67 1,80 1.58 1.65 1.73 15 r2 8 30 24 16 1.2 —1.4- 2.0 35RX3014010 35RX3020010 2.02 Fig. 35C 3— Cap Size in Part Number ______ A in Packing 'Weight lb Inner Master 3/8 1/2 358C3003 0.75 100 200 160 0.3 0.5 359C3004 0.75 80 SMITH-COOPER INTERNX1'1ONAL • TOLL FREE 1-800-766-0076 9 FAX(323)S90-4456 0 wwwsmithcooper.com 114 NSTALLAT'ON STEPS .[NTO WOOD & STEEL STEPS -i TO WCCD & STEELj Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYSu into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4". 3/8", 1/2' or metric all thread rod, bolt stock, (The 1/2" requires the #145W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs, for maximurrrpullout in purl/n steel. Insert the appropriate nut driver into a 318"or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (pin 8114910). With drill unit in a horizontal position and at a right angle to the structural member; begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8' Mb, M8 or metric all thread rod or bolt stock Note: When installing SWOR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. a .4 [INSTALLATION STEPS - AJ"1, INTO CONCRETE] Using an SOS 250 carbide tip bit era HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit ((he bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2'ç or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will, destroy the pullout factor of the screw. INSTALLATION STEPS - Iö O11L INTO CONCRETE: Using an SOS 250 carbide tip bit ore HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammed rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14SW (red) nut driver (pin 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, (urn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill forinstallation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into con tact with the material you are Installing Into, continue drilling until nut driver spins free, Installation is then complete. Warranty requires the use of the appropriate nut driver for installations, .036"-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 .036"-20 ga 3116' 25 125 .188"-3116" 112" 25 125 .036"-20 ga 3/16' 25 125 061Y-16 ga. 1/2" 25 125 ,036"-20 ga 3//6" 25 125 036'-20 ga 3/16 25 125 036'-20 ga 3/16' 25 125 036"-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 03F-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 .036"-20 ga 3/16" 25 125 .125-1/8" 3116' 25 125 .250-1/4" 1/2" 25 125 .188-3/16" 1/4" 25 125 .036"-20qa 3/16" 25 125 - .C36'-20 ga 3/16' 25 125 125"-1/8" 3/16" 25 125 ,188-3/16' 1/2" 25 125 SAMMYS FOR STEEL Made with Teks5 self-drilling fasteners no prednlling required. Installs into steel range from 20 gauge 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. 'A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. 'Made in the U.S.A. fth a doo demoaat'ation at 16;' www.ftwbultdex.com -jr IROIA V-01M iT? P qutB #14 Black Nut Driver Part# 8113910 A -#114SWRO4 W Driver Padt8fl49l0 114" 8024957 DSTR 100 1/4-20 xl' TEKS 3 1510 (20 ga.) 1/4" 8025957 DST 100 1/4-14x1' TEKS 3 446 (20 ga.) 1/4" 8026957 DST 150 1/4-14x1-1/2' TEKS 3 970 (16 ga.) 114W 8027957 DST 200 1/4-14 x 2' TEKS 3 446 (20 go.) 1/4 8030957 TEK 500 12-24 x 1-1/2" TEKS 5 3125 (3/16') 3/8 8038957 DSTR 1 11420 xl TEKS 3 1510 (20 ga) 1500 1475 3/8' 8037957 DSTR 1-1/2 * 12-244 1-1/2 TEKS 5 1510 (3/16') 1500 1475 3/8 8039957 DSTR 616 5/16-18 x 11/4 TEKS 3 2200 (209a) 1500 1475 318' 8040957 DST 10 1/4-1441' TEKS 3 446 (20 ga.) 970 (16 ga.) 3/8" 8077925 DST 10-SS 1/4-14 x 1' TEKS 3 446(20 ga.) 970 (16 ga.) 3/8" 8041957 DST 15 1/4-14 a 1-1/2' TEKS 3 446 (20 ga.) 970 (l6 ga. ) 3/8' 8078925 DST 15-SS 1/4-14 x 1-1/2 TEKS 3 446 (20 ga.) 970 (16 ga.) 3/8' 8042957 DST 20 1/4-14 x 2' TEKS 3 446 (20 ga.( 970 (16 ga,) 3/8" 8043957 DST 25 1/4-14 a 2-1/2" TEKS 3 446 (20 ga.) 970 (16 ga.) 3/8" 8044957 DST 30 1/4-1443' TEKS 3 446 (20 ga.) 970 (16 ga.) 3/8 8045957 DST 516 !V16-18 x 1-1/4 TEKS 3 1500 (3/16) - 1500 1475 ' 3/8' 8046957 TEK 50 12-244 1-1/2" TEKS 5 3125 )3/16'l 1500 - 1475 1/2" 8031925 DST 2.0 1/4-14 x 2' TEKS 3 1/2" 8033925 DSTR 1.0 • 1/4-2011' TEKS 3 1510 (20 ga.) 1/2 8034926 DSTR 5. 16 5116-18x1 1/4 TEKS3 2220 (20ga) 1/2' 8035925 DST 5.16 5/16-18 x 1-1/4" TEKS 3 /500 (3/16') V2' 8036925 TEK5.0 12-24x1-112' TEKS S 3125 (3/16") "Includes retaining nut SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate Installation ff$ each rime. When the face ot the drivercomes into contact with the material you are installing into, continue drilling unril nut driver spins ',..../ free. Installation is then complete, Warranty requires the use of the appropriate nut driver for Installations. EN ~A , 1 01, 1 E ç Made with Inks' self-drilling fasteners- no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. I' rWing • A standard screwgun with a depth sensitive nosepiece should be used to U install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. - • Saves time from traditional methods. Reduces installation costs, Quick to install using the Sammy* Nut Driver with an 18V cordless drillldriver Watch d&O d1mosba8o) Made in the USA. Rod- part Screw ultimate IJL:Test FM Test, Min Max Box Case wer#itwbwldex corn Approvals Size Number Descriptions Pullout (lbs) Load IN) Load (iles) Thickness' Thickness: City Qty I 1/4" 8047957 SWD 100 1/4-14 xl" TEKS 3 1477 (16 ga.) .060'-16 ga 3/16 25 125 1/4" 8049957 SWOR 100° 1/4.20x I"TEKS 3 1900 (20 ga.) .036-209a 3/16" 25 125 3/8" 8050957 SWO 10 1/4-14 xl" TEKS 3 1477 (16 ga.) .060'-16 ga 3/16' 25 125 3/8 8080925 SWD 10 SS 114-14 xl TEKS 3 1477 (16 ga) .060%116 ga 3/16 25 125 3/8" 8051957 SWD 15 1/4-143 1-1/2" TEKS 3 1477 (16 ga,) - .060°-16 ga 3/16' 25 125 - - 3/8'" 8052957 SWD 20 1/4-14x2'TEKS3 1477 )1698.) - .060"-16ga 3116" 25 125 3/8" 8053957 SWD 516 5/16-18x1-1/4TEKS3 2480 (20 ga.) .036-209a 3/16" 25 125 -'' 3/8.8055957 SWDR 1 1/420 xl TEKS 3 1900 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125 N14 SW Red . 'ti 3/8' 8054957 SWDR 1-1/2" 12-248 1-1/2' TEKS 5 2375 (3/16") 1500 1475 .18&-3/16" 1/2 25 125 Nil 0nve( <C? 3/8 8056957 SWDR 516 5/16 183 11/4 TEKS 3 2480 (20 ga) 1500 1475 036 2093 3/16 25 125 P8It#8114910 3/8" 8057957 SWT 15 12-248 1-1/2' TEKS 5 2375 (3/16) .188"3/16" 1/2' 25 125 'Includes retaining nut gyca ion ~lppfication •11flI7/Tuwa. 'Eliminates distortion of threaded rod in sloped roof applications. "Accommodates 3-1/2 x 12 pitch. { "Installs into angled z-puriin; allows threaded rod to hang plumb. Allows 17° deflection from vertical. I ç " '"Made in the U.S.A. I . Watch vtdea dammifrata,, 71 werwitwbulidex.com ScrewApprovals Rod Part Model Ultimate CIL Test FM Test Min Max Box Cas# Size Nwriber I Pullout (lbs) Load (Ibs) Load (Ibs) Thick Thick City Qty r' Nut Drive -1 )'"1t? 3/8' #14 Black 8137957 SHDSTR 1' 3220(3/16') 1500 1475 035' 3/16" 25 125 TEKS 3 Part #81139101 2368(1/2 steel Vertical) " 3/8" 8268957 St+-TEKSO 12-24x1-3/4 1306(45° off Vertical) 1500 (Vertical) 3/18" 1/2" 25 125 TEKS 5 2281 (3/16" HSS) 850 (45' off Vertical) 2-1/2" 1585 (3/16" HSS4S° off Vertical) 2368 (1/2' steel Vertical) 1/2' 8270957 Si-l-TEK 5.0 12-24x1-3/4 1306 (45' off Vertical) 3/16" 1/2" 25 125 014 9H OfxW - - - TEKS 5 2281 (3116- H5S) 1585 (3/16" HSS45 off Vertical) PXIOWMO "Dues not comply with ROHS requitementu/ Includes retaining nut S A lift/Ill Y X- P R E 55 Installs into Metal Deck, Purlin, or Tubular Steel 125' 25 125 Metal Deck 125' 25 125 Metal Deck 125" 25 125 Purlin 00 • Metal Deck 25 125 )Pre-Pour) lbs/ft°' Metal Deck (Post-pour) - The Sammy XPress expands to provide • Less jobsite material needed. direct vertical attachment in: light gauge steel deck or pudin • No retaining nut required. (22g5.- 1/8). Provides design flexibility. 'Installs in seconds with Sammy XPress It' Tool, saving time & installation costs, • Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited, ie, metal root Watch acidac demo Otioc at deck, tubular steel, or vapor barrier fabric. www.itwbuildex.com 1/4' 8181922 XP 200 Sammy X-Press 200 11401229a1 165 (Luminaire) 250 (Luminaire) 02T .056, 3/8' 8150922 XP 20 Sammy X1:20 85012W' Pipe) 1146(2295)185 (Luminaire) 250 (Luminaire) .027" 940 12" Pipe) 029' 1415 (4" Pipe) 283 (Conduit & Cable) .029' 1500(4" Pipe) .060' 318' 8153522 XP 35 Sammy X-Press 35 1703 16 a 185 (Luminaire) 250 ILuminairel .029 056" 940 12" Pipe) 020" 1475 (4' Pipe) 104" 416 )Conduit& Cable) .059" [[ Sammy Pre-Pour Structural Concreleth 30 3/0" 8150922 XP 20 X-Press28 11461229a1 850(2'/oPipel Post-Pour Range II LWCS 35 PCF Pro-Pour Structural Concrete 3080 pat Post-Pour Range It LWC& 35 PCF libel ft°J JrLJrL4 rtb -JJ The SidewInderXPress expands to provide Less jobsite material needed, horizontal attachment in: 16 g 3/16 steel pudirt tubular steel. No retaining nut required 'Installs in seconds with Sammy X-Press Ittc Tool, 'Provides design flexibility. saving time & installation costs. Made in the U.S.A. Use in applicators where access to the back of the installed fastener is prohibited; ie. metal root E(SWXPi deck, tubular steel, or vapor barrierfabric. Cmatt ,dad demomsiraOco at twiwitwbuildex.com - . - 1250 13W Pipe) /L 318" 8293957 SWXP35 tWm03e 1790 ll&gal 80 )Luminaire .059' .125' 25 125 PurLo EM for i. r erne c aflt çoO( The Swivel X.Press allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 45° in metal deck for 12112 pitch Installs in seconds with Sammy X-Press It' Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. Ia. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. 'Provides design flexibility. Made in the U.S.A. Want a eden demqetratJon at °te& www,ltwbulldex.com 750 (2' Pipe) ' 3/9" 0294922 SXP 3.13 Swivel 1061 122 ga Vent) 170 Vertical (Lurninaire) 80 X-Press 20 8291450 Off Vent) @45' (Lum:nxre) 029'635 (2" Pipe) .1329" 283 Vertical (Conduit & Cable) 233 @ 45" (Conduit & Cable) 1250(3.112' Pipe) . <> 3/8 8295922 SXP35 Swine 1675(16gaVert) 250 Vertical (Luminaire) 80@90' (Luminaire) 029' X-Press 35 1558 (890 Off Vert) 635 (2 Pipe) 500 Vertical )Conduit & Cable) 333 @ 990 (Conduit & Cable) 1/2' 8272957 SXP 2.0 Swivel 1061 (22 ga Wit) 027' 125' X-Press 2.0 829)45" Off Veil) 125 25 125 Metal Deck 125' 25 125 Purl/n 25 125 Metal Deck 1/2' 8271957 SXP 3.5 Swivel 1675 (16 ga Vert) X-Press35 1558)89OffVert) .060 .125' 25 125 Purl/n i17ilT1n.is Product Turi Ir The Sammy X.Press expands to provide direct vertical attachment in: -metal deck (22-16 gauge) Z-purlin (18-16 gauge) Made in the U.S.X : Part Number Model Qty Description 8194910 - JXPlr Universal X-Press It tool 1 8152910 XPDB 25164" Drill Bit 1 'Toni includes: Sleeve, Bit Receiver, Htx Wrench, and 25/84' Dill Bit. APPROVALS 8007957 GSTO 3/8" Vertical CPVC1-1/2" 300 I-lIT 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST0 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST 20-OS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST20 3/8" Vertical 4" 1500 1-1/2" 4" 1475 1-1/2' 8009925 GST5-380 3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-388 3/8" Horizontal 3-1/2" - 4" 1508 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2" - 3"* 1050 1-1/2" 8073925 SWG 20-SO 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-G$T/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GSIICST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" I sonJ j 8838957 DSTR1 3/8" Vertical 1500 .035" 4" 1475 105" 8037957 OSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 105" 8039957 OSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 051616 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEKS) 3/8" Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDF 1 3/8" Horizontal 4" 1508 .037" 4 1475 .060" 8056957 SWDR 516 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDF 1-1/2 3/8" Horizontal 4" 1500 .037" 4 1475 .060" 8137957 SH-OSTR 1 318" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105 8268957 SH-TEKSO 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4" 1500 - 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027' 2" 940 8153922 XP 35 3/8" Vertical 4" 1500 .060" , 1475 .125" 8294922 SXP 2') 3/8" Vertical or up to 45" 2" 750 .027" 2" 635 .829" 8295922 SXP 35 3/8" Vertical orupto89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 5WXP35 3/8' Horizontal 3-1/2" 1250 .060" I SAYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC 20 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @300005i 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LtiVC 35 PCF (lbs/ft3) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 8181922 XP 200 1/4" Vertical 185 .027" 250 .035" 8294922 SXP 20 3/8" Vertical 170 .027" 45" 80 .027" 8295922 SXP 35 3/8" Vertical 250 .060" 90" 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" 8150922 XP 25 318' Vertical 283 .021" Max 4 trade size EMI, RMC, and IMC 85 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 580 .060" Max trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3)8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SW)CP 35 3/8" Horizontal 500 .060" Max 4 trade size EMT 86 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2900 1/4" or 3/8' Onto Vertical Rod UL Listed 4516-Cable Hanger, Cat. No. C-Z2000 Plenum Rated, Sheet Steel Complies W/ NEC Standards Gauge No. 22ga. 20 Ilia. 18ga. 169a.. 1491. l2ga. 1/8" 3/18" 1/4' Nominal Decimal Equcealent .030" .038" .048" .060" .075" .105" .125" .188" .250" :SWG 25-380 Man/mum pipe size in composite wood joistallowed by UL is 3-1/2" IL compliance with NEC Standards. SWG 25-380 Maximum pipe aloe In wood Umber or joist allowed by UL s4" UL and FM taxis were performed in compliance with NFPA 13 Standards. "SWG 20 Maximum pipesize in composite wood joist allowed by iL is 2-1/2" '"SWG 20 Man/mum xlaeelze in wand limber or joist allowed by UI. is 3" Fastening reqoirementi 5 times weight of water-tiled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188' and .118". Subsequent testing was done for z-purtin applications in May 1997 using (.037') or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Prese was completed using (.030") or 22 gauge steel metal deck, Sammys Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.00m for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported, Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist, Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: GST 20 /82" 118' GST 25-380 .280" 7/32" SWG 20 .182" 118' SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com A&sourThAscGwTnmcAaEKAow,sE *L$QLflOLS44CWOQLU9d1RE Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made in the U.S.A. Products -. Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 I, 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information 3.3.7 Listincls/AoDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor lndeoendent code evaluation KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data IBC®/ IRC® 2015 IBC®/ IRC® 2012 IBC®/ IRC®2009 IBC®/ IRC®2006 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table I - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter d5t in. 1/4 Nominal embedment h00,0 in. 1-5/8 2-1/2 Effective embedment het I in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T.. ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size - _ (Iamb h , - hnorn h - Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3.4.5 Nominal Nominal Tension - N0 Shear -qv0 anchor embed. f = 2,500 psi f = 3,000 psi f 4,000 psi f = 6,000 psi f', = 2,500 psi f = 3,000 psi f' = 4,000 psi f' = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' .2,3.4.5 Nominal Nominal Tension - cN Shear - On f' = 2,500 psi f', = 3,000 psi f = 4,000 psi f = 6,000 psi I' = 2,500 psi I = 3,000 psi f' = 4,000 psi f, = 6,000 psi anchor embed. diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by k as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked Concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a500 = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - a N..14 = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile' Shear4 Seismic shear' diameter thread diameter cpN 4Vsa 0 in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension = tPAonN as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with cpV <0.6qA,0 , as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with pV,0 C 4 0.60 A,00 f as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 uncracked concrete 'AN 'RN LW 'NV fRy Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0 (mm) (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 1 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a g 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a -- - 3-1/2 (89) 0.99 1 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a ' 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 0.89 5-1/2 0.98 (140) 0.83 0.72 0.93 6 (152)__ 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 10 (2 4) 0.89 0. 11 (279) 0.93 12 (305) 0.97 - 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete' 2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear4 cracked concrete 'AN 'RN lAy 'NV 'NV 'HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 0,,> (mm) (41) (64) 1 (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a a> 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 _______ 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a ,Sa ' 4 (102) 1.00 0.85 _______ 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 a> 5-1/2 (140) 0.98 0.83 0.72 0.93 _6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 _8 (203) 0.98 0.82 1 9 (229) 1.00 0.86 6. 10(254) 0.90 11(279) 0.94 12(305) 0.98 - 14(356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f., assumes an influence of a nearby edge. If no edge exists, then fAR = f. 4 Concrete thickness reduction factor in shear, f assumes an influence of a nearby edge. If no edge exists, then f = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. 3.3.7 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7- Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck"2'3'4'5'6'7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - cpN Shear - V,, Tension - cpN Shear - 4V anchor thread embed. f',,= 3,000 psi f'= 4,000 psi f'= 3,000 psi 4,000 psi F 3,000 psi f'0= 4,000 psi f',,= 3,000 psi 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1/4 ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - cpN0 Shear - cpV Tension - 4N Shear - anchor thread embed. '= 3,000 psi f= 4,000 psi 3,000 psi ',,= 4,000 psi r= 3,000 psi f'= 4,000 psif', = 3,000 psi F'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in, in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 / 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h 0,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads Only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,OI = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH.EZ I) in soffit of concrete over steel deck floor and roof assemblies Min, 3/4 - ,- - -- Min. 3,000 psi sand-(ightweight Si A re e JO upp flute Min, 4-11P" Anchor Flute edge Lower (typical) flute Mm. 1-1/4 Mm. 12 (typical) (ridge) Minimum 20 gauge steel deck 1 Anchors may be placed In the upper or tower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile Shear4 Shear4 diameter diameter N V, in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N, = A N 4 f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v, < 4 0.6 f R as noted in CSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V r <A0 4 0.6 f R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (5) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3.14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 AnchorO.D. d in. 1/4a (mm) (6.4) Effective embedment' hef in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 h ,,0,,, in. 1-5/8 2-1/2 (mm) (41) (64) Minimum concrete thickness h in. 3-1/4 4-1/8 (mm) (83) (105) Critical edge distance c,,,, in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance in. 1.5 (mm) (38) Minimum edge distance Cmin in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for 5> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 I (mm) (51) I (73) Minimum specified ultimate strength f..(N/mm2) psi 125,000 (862) Effective tensile stress area AS.,, in 0.045 (mm2) (29.0) Steel embed. material resistance factor for reinforcement 4) - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension N ,,,,, lb 3,370 0.6.1.2 (kN) (15.0) Factored steel resistance in shear Vs,,r lb 750 0.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic Vwreq (kN) (1.5) Factored steel resistance in shear V lb 725 0.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic VWeq (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete keener - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked cone.' N - 1.0 0.6.2.6 Anchor category - - 1 D.5.3 (C) Concrete material resistance factor q'c - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B6 Factored pullout resistance in 20 MPa uncracked concrete' Npruncr lb 665 1,645 D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete Np,cr lb 340 815 0.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete Npr,, lb 275 815 D.6.3.2 (kN) (1.2) (3.6) 1 Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section 0.2. For all design cases, 4cN = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k00,) or uncracked concrete (k,,,,,,) must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section 0.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, rp,,,, = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete' 2,3,4,5 Nominal __________ Tension - N Shear - V, f' = 20 MPa f' = 25 MPa f'c = 30 MPa f' = 40 MPa f'c = 20 MPa f'c = 25 MPa f = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concrete 1,Z3,4,5 Nominal Tension - N Shear - V __________ f = 20 MPa I',, = 25 MPa f = 30 MPa f = 40 MPa f'c = 20 MPa f' = 25 MPa f' = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A. as follows: for sand-lightweight, i = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - slil = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aRsds = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hllti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2-3,4,5,6,7 N Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - N Shear - Vr Tension - Nr Shear - Vr anchor thread embed. f'c = 20 MPa f, = 30 MPa f', = 20 MPa f'c = 30 MPa f', = 20 MPa f', = 30 MPa f = 20 MPa f', = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"2'3'5'6'7'8 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N, Shear - Vr Tension - N, Shear - Vr anchor thread embed. f = 20 MPa IC = 30 MPa f', = 20 MPa IC = 30 MPa IC = 20 MPa IC = 30 MPa f = 20 MPa IC = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASO value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h 0,,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by c(NC, = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hitti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels'2 Hanger rod size Mm. effective embedment h in. Allowable load' Ultimate load Tension lb Shear lb45 Tension lb Shear lb 4.5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimension[ configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 Mi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 Installation of Hilti KWIK HUS—EZ I (KH-EZ I) In hollow core concrete 3.3.7 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1.5/8 13/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WiJ100 3/8 1,S6 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C 0 E F Load Lbs.* WtJ100 3/8 1,S6 11/4 1 7/16 1 610 28 1/2 1½ 11/4 1 9/16 11/4 1130 55 5/8 1112 11/4 1 9/16 11/4 1130 55 Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of S US USTED Seismic Restraints System California OSHPD Approved c Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4' (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.137.5599 • FAX; 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer c® US LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity, The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER 8-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 W&A COOPER B-Line Dimensions • Weights Rod Max. Rec, Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c Vt. us usmo Seismic Restraints System Size Range - Secures /8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSI-IPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electra-Galvanized and HOG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11h 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 . PIt 9517375539 • FAX; 9517370330 CUSTOMER SERVICE . 800780,5266 www.tolco.com Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily "44 installed around pipe. " - -••• A For hanger with non-captured nut order Fig, 200S. (2/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in '.. hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fi 200-1 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200C Fig. 200F Fig. 200-1/2. 20O-I4 Fig, 200_21!2 to 200-8 Fig. 200 Fig. 200S i:ei1rrgetrs Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) OVOLCor Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Vi us Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut lii (00 liiiim i'A1 t (lJ) 200-1/2 1/2" (15) /8"-16 31/8° (79.4) 2/8 (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2' (63.5) 11 (50) 200-1 1" (25) /8"-16 33/8' (85.7) 2/t" (66.7) 12 (5.5) 200_11/4 1 11/4" (32) /811-16 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200_11/2 11/2" (40) /8"-16 3/8" (98.4) 27/8' (73.0) 14 (6.4) 200-2 (50) I8'-16 41/2' (114.3) (76.3) 15 (6.9) 200_21/2 21/2" (65) I8"-16 5/8" (142.9) 41/8' (104.7) 27 (12.3) 200-3 3" (75) /8'-16 57/8" (149.1) 4" (101.6) 29 (13,3) 200-31/2 31/2" (90) /8"-16 73/8" (187.3) 51/4' (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 112".,13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"..13 131/8" (333.4) 8/4' (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line aipeliiiarrgeFiSTI Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds It securely in hanger before installation, Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut, Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. 44 Fig. 200-1 to 200-2 Fig. 200-/2. 200-14 Fig. 200-21/2 to 200-8 il!l& -- IiI 015Th '1 II) (l11101j awsam 5 _____ 200M8-1/2 1/2 (15) M8 31/8 (79.4) 2/8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8' (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8 (79.4) 21/2 ' (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79,4) 21/2 (63.5) 11 (5.0) 200M8-1 1" (25) M8 33/8 (85.7) 2/8' (66.7) 12 (5.5) 200M1-1 1" (25) M10 33/8 (85.7) 2/8' (66.7) 12 (5.5) 200M8-11/4 11/4" (32) MB 33/4' (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2/8 (73.0) 13 (5.9) 200M8-11/2 11/2 (40) M8 3f (98.4) 2/8' (73.0) 14 (6.4) 200M10-11/2 11/2 (40) M10 3/8' (98.4) 2/8' (73.0) 14 (6.4) 200M8-2 2' (50) M8 41/2' (114.3) 3" (76.3) 15 (6.9) 200M10-2 (50) M10 41/2 (114,3) (76.3) 15 (6.9) 200M-21/2 21/2 (65) M10 5/a' (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) M10 5/8 (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7/8 (187.3) 51/4' (133.3) 34 (15,6) 200M-4 4" (1 00) M10 7I8' (187.3) 5" (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8' (231.8) 61/4' (158.7) 66 (30.2) 200M-6 6" (150) M12 10118 (257.2) 6I4' (171.4) 73 (33.4) 200M-8 8' (200) M12 131/8 (333.4) 1 8/4 (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches, Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line 0, I 0 0. 0. ip:eirge Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2' (50mm) thru 4" (100mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8'-16 or 1/2"..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada * (cUL). Conforms to Federal Specification WW-H-171E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. Ia ID On To (019Th 1j 200H-2-3/8 2" (50) /8"-16 4i1' (115,9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2"_13 423/32" (119,8) 33/8" (85.7) 45 (20.4) 200H-2112-318 21/2' (65) /8'-16 55/16" (134.9) 323/32" (94.4) 59 (26.7) 200H-2112-112 21/2" (65) 112".13 515/32" (138.9) 3/a" (98.3) 56 (25.4) 200H-3-3/8 3" (75) /8'-16 53/4' (146.0) 327/32" (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"_13 57/8" (148.1) 331/32' (100.8) 60 (27.2) 200H-4-3/8 4' (100) /8"-16 6/8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" 1 (100) 1 1/2"_13 71/32" (178.6) 419/32" 1 (1116.7) 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8' (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Vu Rel MOORasLIL!uUriLeaii M51611M P 1 Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. j Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G MS/-. YST!M CWP'TtL1 *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 - TEL +1/60 599-1168 +1800344-1822 FAX +1800344-3775 Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. NIIIIIIIII bA MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPPI, LubeFitO are registered trademarks of Fire Protection Products, Inc. FOG/BM/CZ'", Blaze-Mastef, FlowGuard Golcfl' and Corzan are registered trademarks of Noveon IP Holdings Corp. i adT gftmvgij1 F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. F DO st/_. *FBCTh System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 1 3198 LIONSHEAD AVE - CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5g1. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com © 2012 Fire Protection Products, Inc. FPPIA, LubeFto are registered trademarks of Fire Protection Products, Inc. FBC", BlazeMaster®, FlowGuard Golds and Corzan® are registered trademarks of Noveon IP Holdings Corp. Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. Ti' Mrime:a:d I 1Tihie:a:dIGiittuirgi@i I I I H Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and Is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. WN ) 2013 Fire Protection Products, Inc. FPPF, ThreadFit- are registered trademarks of Fire Protection Products, Inc. MADE IN ,... Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke IFINK; SYSTEM COMPATIBLE *F13CT1 System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE - CA8LSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX+ 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.