Loading...
HomeMy WebLinkAbout6185 PASEO DEL NORTE; 100; FPC2021-0096; PermitPERMIT REPORT (City of Carlsbad Print Date: 08/09/2021 Permit No: FPC2021-0096 Job Address: Permit Type: Parcel #: Valuation: Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: 6185 PASEO DEL NORTE, # 100, FIRE-Construction Commercial 2110401800 $236,422.16 CARLSBAD, CA 92011-1152 Work Class: Fire Alarm Track #: Lot U: Project U: Plan U: Construction Type: Orig. Plan Check U: Plan Check U: Status: Closed - Finaled Applied: 06/07/2021 Issued: 07/22/2021 Finaled Close Out: 08/09/2021 Inspector: Final Inspection: Project Title: Description: TRI-CITY HEALTH -INSTALL NEW PAD-4 POWER SUPPLY NEXT TO EXISTING SIEMENS CONVENTIONAL FIRE ALARM PANEL Applicant: FPContractor: SIEMENS SIEMENS INDUSTRY INC CHRIS BISCHEL P0 BOX 80600 10100 WILLOW CREEK RD INDIANAPOLIS, IN 46280-0600 SAN DIEGO, CA 92131-1636 (630) 857-2100 (858) 265-9894 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov - TRI-CITY HEALTH FIRE ALARM T.I. 6185 PASEO DEL NORTE, SUITE 100 CARLSBAD, CA 92011 Siemens Project #: 440P-312792 Date: June 1, 2021 Rev: 01 SIEMENS Data Sheet Fire Safety Products FACP Accessories PAD-4 Distributed Power Supply Unit [for ®UL markets] Notification Appliance Circuit Extender Models PAD-4-ENCL, PAD-4-MB (with FP20II-1.1I, FP2012-UI power supplies) ARCHITECT AND ENGINEER SPECIFICATIONS . Four (4) 'Class B', power-limited notification appliance circuits (NACs) 'Class A', field-selectable wiring Each unit can support an optional module (Model PAD-4-CLSA) that converts two (2) built-in 'Class A' NACs into four (4) 'Class A' NACs Up to 3 Amps of auxiliary-power output Optional built-in strobe synchronization Supports coded audible signals, including Temporal 3, Temporal 4 patterns Battery supervision and control 'Form C' general Trouble I AC Fail monitoring contact 'Class A' Adapter Card [Model PAD-4-CLSA) Power supplies support NAC power Up to 6A used with Model FP2011-Ui Up to 9A used with Model FP2012-Ui 24VDC output voltage Ground-fault detection Advanced microprocessor control Uses Flash memory-based system firmware Optional system-diagnostic and firmware-upgrade tool Product Overview Used with Siemens - Fire Safety fire alarm control panels (FACPs), the Distributed Power Supply PAD-4 Unit is a NAC expander with a built-in, auxiliary- power output. Each PAD-4 unit distributes additional power in buildings for audible and visual indicators that conform to the Americans with Disabilities Act (ADA). PAD-4 also has the following features: NACs Signal-input circuits Battery-charging circuit Trouble relays for remote monitoring Diagnostic light-emitting diodes (LEDs) Alternating Current (AC) power connection The Siemens NACs, which connect with alarm signaling devices, have been designed to provide the highest level of reliability and performance. Signal coding on the circuits is accomplished through integrated circuits (rather than relays), which eliminates mechanical wear on the output circuits. Main Board Unit Enclosure [Model PAD-4-MB] [Model PAD-4-ENCLI Multi-module mounting in System 3 enclosures Multiple modules share battery set ADA Compliant ®UL 864 9th Edition Listed, ®UL 1481 Listed; FM (3010), CSFM (7315-0067:0268) Approved The PAD-4 unit provides constant 24VDC output voltage to each NAC - independent of voltage fluctuations on the primary or secondary power source. As a result, a larger voltage drop and a greater wire length for each NAC are supported by each PAD-4. Specifications This version of the Siemens Distributed Power Supply Unit can be configured in the following manner that makes the outputs easily programmable: 'STEADY' outputs Synchronized strobe outputs American National Standards Institute (ANSI) Temporal 3 ANSI Temporal 4 [for carbon monoxide (CO) alarm signal] There are also two (2) inputs used to control the activation of the four (4) outputs. Programming can be set so one (1) input will silence the audible signal on Siemens Models 'AS'-series, 'NS'-series, or 'ZH'- series horn and horn-strobes while the strobes remain active. Distributed Power Supply— NAC Extender (Model PAD-4 series) 3363 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) Operation of each PAD-4 unit is controlled by firmware stored in Flash memory on the main board, as well as the storage of a 10-event log, which can be viewed via Model PAD-4-FDT. In the event that an upgrade to the system firmware is required, the firmware can be transferred to the system without the replacement of firmware chips. An optional firmware-download software tool, Model PAD-4-FDT, can be used for system- diagnostic testing of the following: Primary-power voltage readouts Current draw for power charger Configuration switch settings Firmware version Battery voltage When the tool is in communication with Model PAD- 4-MB, the 'Test Mode' LED is illuminated. Model PAD-4-LUA is a USB serial port adapter that is required for tool-kit operation. Each NAC extender supervises a variety of functions including: Low AC power Battery-voltage level Earth ground-fault conditions All power can be directed to two (2) 'Class A' or four (4) 'Class B' power-limited NACs. Each NAC supports up to 3 Amps per circuit. Either one (1) or two (2) inputs can control four (4) outputs, which are compatible with all Siemens - Fire Safety 24VDC alarm signaling devices. In cases where 'Class A' circuits are used, an optional Model PAD-4-CLSA module can be added, providing two (2) additional 'Class A' outputs to each PAD-4 unit. Each NAC extender is also capable of operating other parts of a Siemens fire alarm system, such as door holders, via 3 Amps @ 24VDC max of power-limited auxiliary output. When the output activated, the total power available cannot exceed 6 Amps when used with Models FP2011-U1 or 9 Amps when used with FP2012-U1. Trouble conditions are monitored through each unit's two (2) inputs. In addition, one (1) 'Form C' Trouble contact is provided for monitoring each unit that is connected through the input of a Siemens FACP. Therefore, the user has the option of connecting a PAD-4 NAC extender unit into a NAC of a Siemens FACP, or the unit may be monitored with a Model TRI-series monitoring module on a Siemens intelligent fire system. A separate 'Form C' Trouble contact is used exclusively with each NAC extender to indicate AC Fail Trouble events on the NAC extender. SIEMENS Industry, Inc. Building Technologies Division Each unit is packaged in its own sheet-metal enclosure with sufficient space to house up to 7AH battery sets. The enclosure (Model PAD-4-ENCL) is available in red. The battery charger used in each unit can energize batteries of up to 1 8AH. Though, when battery sets greater than 7AH are required, the battery set must be housed in a System 3 enclosure or a separate ®UL Listed battery enclosure. System 3 enclosures may also be used to house multiple Model PAD-4 units in a single enclosure, via the Model S3AP Adapter Plate. Two (2) units are capable of sharing the same battery set when mounted in the same enclosure. Model S3AP can also be used to mount the PAD-4 main board and 170-Watt power supply (Model FP2011-U1) into a PAD-3 enclosure. Each Model PAD-4 unit complies with seismic certification, pursuant to the following: ASCE Standard 7, 2005 Edition International Building Code, 2006 Edition California Building Code, 2007 Edition ICC-ES AC 156, effective 2007 OSHPD preapproved, under: OSP-0057-1 0 - OSHPD CAN 2-1708A.5, Rev. 3 Each Model PAD-4-series unit also complies with seismic certification, pursuant to ASC I SET 7-05, Section 13.2.2, when used with the PAD-4 battery bracket (Model PAD4-BATT-BRKT). Configuration Options Option Input[s] Output Controls Circuit Types 1 Input 1 All outputs 'Class B' circuits Input 1 All outputs Class B' circuits 2 Input 2* Silences horns on Output 1 - Input 1 Outputs 1 and 2 Class B' circuits 3 Input 2 Outputs 3 and 4 'Class B' circuits Input 1 Output 1 'Class B' circuits 4 Input 2 Outputs 2, 3 and 4 Class B' circuits 5 Input 1 Outputs 1 through 4 'Class A' circuit pairs Input 1 Outputs 1 through 4 'Class A' 6 circuit pairs Input 2* Silences horns on Output 1 Input 1 Outputs 1 and 2 'Class A' circuit pairs 7 Input 2 Outputs 3 and 4 'Class A' circuit pairs * denotes when used with Siemens Model 'AS','NS'or 7W-series horn /strobe devices Indicator Lights AC Power ON: AUX iPS: Yellow Ground Fault: Yellow Output 1 Trouble: Yellow Output 2 Trouble: T Yellow Output 3 Trouble: Yellow Output 4 Trouble: Yellow I Test Mode: II Yellow I Technical Data AC Fail Trouble Contact Rating: 2.OA @ 30VDC, max. 'Form A'- Normally Closed (NC) I [resistive] Basic Trouble Contact Rating: 2.OA @ 30VDC, max. 'Form C) [resistive] 3.OA per circuit, max. Alarm Current: 6A, max. (via Model FP2011-U1} for NAcs and auxiliary power) 9A, max. (via Model FP2012-1.11} Ambient 32° - 1200 F Temperature: (00_ 49° C) Relative Humidity: Up to 93% @860 F(30° C); non-condensing Auxiliary Power Circuit: One (1) circuit @ 3A max. Battery Charging Capacity: 1 8AH Input Circuits , Two (2) 'Class B' supervised Configurations: or Two (2) 'Class A' supervised Input Current: 7.0mA, max. Input Voltage Range: 16-33VDC/VFW Installation Environment: Indoor, dry Supervised, power-limited 0 1.0mA standby current, max.- NACs: Four (4) circuits 02K ohms (+), 8K ohms (-) 24VDC @ 6 Amps Total Output Power: (with Model FF2011-U1) 24VDC @ 9 Amps (with Model FP2012-U1) 0 Two (2)'Class A'; - Up to four (4) 'Class A' Output Circuits I sA Configurations: 0 ----- 0 One (1)Class A, Two (2) Class B; Single-Unit Dimensions: {W -x-H -x- D) 13.5 -x- 18.75 -x- 3.25 Model_PAD-4-ENCL cm. -x- 47.6 cm. -x- 8.3 cm.) .....................................................(34.3 Red Model_PAD-4-ENCL SIEMENS Industry, Inc. Building Technologies Division Temperature and Humidity Range Each PAD-4 Distributed Power Supply Unit is ®UL 864 gth Edition Listed for indoor dry locations within a temperature range of 1 2OI-3°F (49I-2°C) to 32I-3°F (0I-2°C) and a relative humidity of 93I-2% at a temperature of 9O/-3°F (32/-2°C). Details for Ordering Model Part Number Description PAD-4-ENCL 500-050081 PAD-unit enclosure PAD-4-MB 500-650217 PAD-unit main board FP2011-LJ1 500-450222 L 170 Watt power supply FP2012-Ui S54400-Z60-A1 300-Watt power supply —System Kits — Model Part Description Number Complete 6A PAD-4 kit with: PAD4-6A 554339-Al -Al - One (1) Unit Enclosure, PAD-4-ENCL - One (1) Main Board, PAD-4-MB - One (1)170W power supply, FF201 1-U1 Complete 6A PAD-4 kit with: - One (1) Unit Enclosure, PAD-4 ENCL PAD46A-CLSA 554339-A2-A1 - One (1) Main Board, PAD-4-MB - One (1)170W power supply, FP2011-U1 - One (1) 'Class A' Adapter card, PAD-4-CLSA Complete 9A PAD-4 kit with: PAD4-9A 554339-A3-A1 - One (1) Unit Enclosure, PAD-4-ENCL - One (1) Main Board, PAD-4-MO - One (1) 300W power supply, FP2012-Ui Complete 9A PAD-4 kit with: - One (1) Unit Enclosure, PAD-4-ENCL PAD4-9A-CLSA S54339-A4-A1 - One (1) Main Board, PAD-4-MB - One (1)300W power supply, FF2012-Ui - One (1) 'Class A' Adapter Card, PAD-4-CLSA -Optional Accessories Model Part Number Description PAD4-BATT-BRKT 554430-B4-A1 Battery bracket for NAC expander PAD-4-LUA S54389-Cl-Al PAD-4 Laptop-Upload Adapter PAD-4-CLSA 500-850254 'Class A' Adapter Card S3AP 500-650257 PAD-4 NAC expander adapter plate (for use with PAD-3 and System 3 enclosures) Note: For the data sheet of the PAD-4 NAC Extender sold in Canada, please see document, 3363C. Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety 8 Fernwood Road SIEMENS Industry, Inc. Florham Park, Ni 07932 June 2017 Building Technologies Division Tel: (973) 5932600 (SIIFS) Supersedes sheet dated 11/2015 FAX: (908) 547-6877 Printed in U.S.A. (Rev. 6) URL: www.usaSiemens.comjFire ZH Series F1E Series (for mounting) SIEMENS Data Sheet Fire Safety Products Notification Appliances_________ ZH & ZR - Strobes, Horns, & Horn I Strobes I Application: Indoor Product Overview - Strobes can be synchronized using the Siemens DSC sync modules, the Siemens 50-point, 252-point and 504-point addressable fire alarm control panels (FACPs), as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD-4 TM NAC Extenders with built-in sync protocol - Selectable Continuous Horn or Temporal (Code-3) Tones with 90 or 95 dBA selectable setting (Series 'ZH') - Ceiling-mount models feature field-selectable Candela settings of 1 5/30/75/95cd and 11 5/1 77cd - Wall-mount models feature field-selectable Candela settings of 15/30/75111 Occl and 135/1 85cd - Base plate is protected by a disposable cover, and the appliances can quickly snap onto the base after the walls are painted - Strobes produce one (1) flash per second - "Special Applications" listed with Siemens panels - EZ Mount Universal Mounting Plate (Model ZB Series) —uses single plate for ceiling and wall mount installations - EZ Mount design —with separate base plate —provides ability to pre-wire the base and test the circuit wiring before the walls are covered - ®UL Listed & OULC Listed, FM (#3028994) Approved; CSFM Approved (Series 'ZH': #71250067:0248 —> Fire Alarm Devices For The Hearing Impaired) CSFM Approved (Series 'ZR': #71250067:0252 —> Fire Alarm Devices For The Hearing Impaired) - ADA / NEPA compliant Specifications . General - Audible/Visual notification appliances are listed for indoor use only - Appliances are listed under ®UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired) and ®UL Standard 464 (Fire Protective Signaling) - Appliances use a universal back plate, which allows mounting to a single-gang, double-gang, 4-inch-square (10.2 cm.), 4"-octal (10.2 cm.), or a 3-1/2" (8.9 cm.) octal backbox - Two-wire configurations allows capability for directly connecting appliances to the mounting back plate - Continuity check will occur for entire NAC circuit prior to attaching any audible / visual-notification appliances - A cover fits over the mounting plate for protection to dust and other outside elements Cover is easily removed when the appliance is installed over the back plate - Removal of an appliance will result in a Trouble condition by the Siemens Fire Alarm Control Panel (FACP) 'Z' Series Notification Appliances 2584 SIEMENS Industry, Inc. Building Technologies Division Specifications - (continued) Strobes and Audible Strobe Combinations - Strobe appliances produce a minimum flash rate of 60 flashes per minute (one [1] flash per second) over the Regulated Input Voltage Range, and incorporate a Xenon flashtube enclosed in a rugged Lexan® lens - Strobes are available with two (2) or four (4) field-selectable settings in one (1) unit, and are rated - per ®UL 1971 - for up to: 15/30175/ll0cd for wall mounted 135/185cd for wall mounted 1 5/30/75/95cd for ceiling mounted 115/1 77cd for ceiling mounted - Strobes operate over an extended temperature range of 32°F to 1207 (0°C to 49°C), and be listed for maximum humidity of 95% RH - Strobe inputs are polarized for compatibility with standard reverse-polarity supervision of circuit wiring by a Siemens FACP Audible and Audible I Strobe Combinations - Horns and horn I strobes are listed for Indoor use under ®UL Standard 464 - Horns are able to produce continuous synchronized output or a Temporal Code-3 synchronized output - Horns have at least two (2) sound-level settings of 90 and 95 dBA Synchronization Modules - The strobe portion, when synchronization is required, is compatible with the Siemens DSC sync modules; the Siemens 50-point, 252-point and 504-point addressable FACPs, as well as with: FireFinder® XLS and MXL® FACPs PAD-3 or PAD4TM NAC Extenders with built-in sync protocol - The strobes will not drift out of synchronization at any time during operation - Audibles and strobes are able to synchronize on a two-wire circuit with the capability to silence the audible, if required - Strobes revert to a non-synchronized flash-rate, if the sync module or power supply should fail to operate (i.e. - contacts remain closed) - All notification appliances are listed for Special Applications: Strobes are designed to flash at 1-flash-per-second minimum over their ''Regulated Input Voltage Range" > Note: NFPA-72 specifies a flash rate of 1-to-2 flashes per second, and ADA Guidelines specify a flash rate of 1-to-3 flashes per second All candela ratings represent minimum-effective Strobe intensity, based on ®UL Standard 1971 Series ZH Strobe products are listed under ®UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% ( 2%) Series ZH horns are listed under ®UL Standard 464 for audible signal appliances (Indoor use only) Mounting Diagram SIEMENS Industry, Inc. - (Shown In Inches) Building Technologies Division Mounting Diagram e SECURING SM SCREWS OPENmO I'M FtAT SCREWI*000.-J Installation I.) With the provided pan head screws, install mounting plate to a: - aingle-gang; - double-gang; - 4 (10.2 cm.) square; - V (10.2 cm.) octagon backbox Connect the field wiling. Address wires back into backbox. Place dust cover over mounting plate to protect the terminals while performing the wiring-continuity check. Remove dust cover before snapping or installing the appliance onto the mounting plate Technical Data Removal ImportanI: Device only has one (1) mounting orientation. Match the top of the base to the top of the device. If it is desired to further secure the device to the base, then use the two (2) optional screws which are provided in the shipment To Install, punch out the screw holes located at the top and bottom of the device. To remove the appliance, push a small, flat-bladed screwdriver into the side opening. The screwdriver must dear the snap release opening by 1/4 "(0.64cm.), in order for the appliance's snap to disengage. inipeitan(: Do not pry off the housing with a screw driver. ZH Horn: Wall and Ceiling Mount Operating Voltage (Special Application) Per®UL 464 Input Voltage Low* High* DC 1 16.0-33.OVDC 0.018 0.044 FWR 1 16.0 - 33.OVRMS 0.045 0.075 * Current draw is the same for the Continuous Horn, Code 3 Horn, and March Time settings ZH Horn I Strobe Series: Wall Mount ZH Horn I Strobe Series: Ceiling Mount Current Ratings (AMPs) MAXIMUM RMS Current- with High dBA Setting Input Voltage 15cd 3 c 75cd llOcd 135cd 185cd DC I 16.0-33.OVDC 0.078 0.113 10.195 0.259 0.371 0.506 FWR 16.0-33.OVRMS 0.141 0.200 0.302 0.406 0.521 0.722 Current Ratings (AMPs) MAXIMUM RMS Current- with Low dBA Setting Input Voltage l5cd 30cd 75cd 95cd 135cd 185cd DC 116.0-33.OVDC 10.070 10.107 10.18810.246101.324 0.455 FWR 16.0-33.OVRMS 0.123 0.179 0.290 0.391 0.497 0.699 ZR Strobe Series: Wall Mount Current Ratings (AMPs) Strobe Setting - (cd) Input Voltage 15cd I 30cd I 75cd 110cd 135cd I 185cd DC 16.0-33.OVDC 10.06410.098 10.17510.23310.318 0.445 FWR 16.0-33.0VRMS 10.10810.164 10.26810.36810.48210.684 ZR Strobe Series: Ceiling Mount Current Ratings (AMPs) Strobe Setting - (cd) Input Voltage 15cd I 30cd I 75cd I 95cd 1 11 5c I 177cd DC 116.0-33.0V1)C I 0.069 10.11110.20010.26410.318 10.445 FWR 116.0-33.OVRMSI 0.117 10.180 10.29710.39810.482 10.684 @ULC Directional Characteristics -3 dBA 35 degrees left; 40 degrees right -6 dBA 55 degrees left; 65 degrees right SIEMENS Industry, Inc. Building Technologies Division Current Ratings (AMPs) MAXIMUM RMS Current- with tLigh dBA Setting Input Voltage 15cd 30cd 75cd 95cd ll5cd 177cd DC 16.0-33.OVDC 0.087 0.131 0.222 0.292 0.371 0.506 FWR 16.0-33.OVRMS 0.149 0.216 0.331 0.436 0.521 0.722 Current Ratings (AMPs) MAXIMUM RMS Current- with Low dBA Setting Input Voltage 15cd 30cd 75cd 95cd I ll5cd 177cd DC 16.0-33.OVDC 0.075 0.121 0.213 0.277 0.324 0.455 FWR 116.0-33.OVRMS 0.131 0.195 10.31910.42110.497 0.699 ZH and ZH-MC Series: Wall and Ceiling Mount dBA Sound Output Description Volume Reverberant Per ®UL 464 16.0 VDC 24.0 VDC 33.0 VDC Continuous Horn Low 77 81 83 High 83 87 90 Code 3 Horn (or March Time)* I Low 72 76 79 High 79 1 82 1 86 dBA Sound Output Description Volume Reverberant Per ULC-S525-99 20.0 VDC 24.0 VDC 31.0 VDC Continuous Horn Low 88 90 91 High 93 95 96 Code 3 Horn (or March Time)*11 Low 88 90 91 High 93 95 96 ** Available only in sync mode. Technical Data - (continued) Notes: 1. Strobes will produce 1 flash per second over the Input Voltage range. These horn/strobe models are ®UL Listed to operate over a Voltage Range Limit from 1 6.OVDC to 33.OVDC for 24VDC applications using filtered DC or unfiltered Full-Wave-Rectified (FWR) input voltage. All models are ®UL Listed for indoor ceiling use with a temperature range of +0°C to +49°C (+32°F to +1200F) and maximum humidity of 93% +1- 2% RH. The effect of shipping and storage temperatures will not adversely affect the performance of the appliance when stored in original cartons, and is not subjected to either misuse or improper handling of shipment. Details for Ordering - (Including Mounting Options & Agency Approvals) Agency Approvals Model Part Number Description Mounting UL Options* ULC FM CSFM ZH-R 500-636159 Z Horn: Red B,D,E,F,X V V V V ZH-W 500-636160 Z Horn: White B,D,E,F,X V V V V ZH-MC-R 500-636161 Z Horn: Multi Candela (Wall), Red B,D,E,F,X V V V V ZH-MC-W 500-636162 Z Horn: Multi Candela (Wall), White B,D,E,F,X V V V V ZH-HMC-R 500-636163 Z Horn: Hi Multi Candela (Wall), Red B,D,E,F,X V V V V ZH-HMC-W 500-636164 Z Horn: Hi Multi Candela (Wall), White B,D,E,F,X V V V V ZH-MC-CR 500-636165 Z Horn: Multi Candela (Ceiling), Red B,D,E,F,X V V V V ZH-MC-CW 500-636166 Z Horn: Multi Candela (Ceiling), White B,D,E,F,X V V V V ZH-HMC-CR 500-636167 Z Horn: Hi Multi Candela (Ceiling), Red B,D,E,F,X V V V V ZH-HMC-CW 500-636168 Z Horn: Hi Multi Candela (Ceiling), White B,D,E,F,X V V V V ZR-MC-R 500-636169 Z Strobe: Multi Candela (Wall), Red B,D,E,F,X V V V V ZR-MC-W 500-636170 Z Strobe: Multi Candela (Wall), White B,D,E,F,X V V V V ZR-HMC-R 500-636171 Z Strobe: Hi Multi-Candela (Wall), Red B,D,E,F,X V V V V ZR-HMC-W 500-636172 Z Strobe: Hi Multi-Candela (Wall), White B,D,E,F,X V V V V ZR-MC-CR 500-636173 Z Strobe: Multi Candela (Ceiling), Red B,D,E,F,X V V V V ZR-MC-CW 500-636174 Z Strobe: Multi Candela (Ceiling), White B,D,E,F,X V V V V ZR-HMC-CR 500-636175 Z Strobe: Hi Multi Candela (Ceiling), Red B,D,E,F,X V V V V ZR-HMC-CW 500-636176 Z Strobe: Hi Multi Candela (Ceiling), White B,D,E,F,X V V V V ZB-R 500-636193 Accessory -(Includes base, dust cover, mounting screws and installation sheet) V V V V ZB-W 500-636194 Accessory - (Includes base, dust cover, i mounting screws and installation sheet) V V V V V = Listed I Approved * = Refer to data sheet #: 2585 for detailed mounting options Notice: This marketing data sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product's installation instructions. Fire Safety Fire Safety 8 Fernwood Road 1577 North Service Road SIEMENS Industry, Inc. Florham Park, Ni 07932 East Oakville, Ontario August 2016 Building Technologies Division Tel: (973) 593-2600 sii L6H 01-16 I Canada Supersedes sheet dated 6/2015 FAX: (908) 547-6877 Printed in U.S.A. Tel: [905] 465-8000 )Rev. 5) URL: www.usa.Siemens.comlFire URL: www.siemens.cA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0248 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: James Muha (973) 593-2664 Fax (973) 593-6652 Email: james.muha@siemens.com DESIGN: Models NH-R, NH-W, NH-CR, NH-CW, ZH-R, and ZH-W horns and models NS-MC-R, NS-MC-W, ZH-MC-R, ZH-MC-W, ZH-HMC-R, AND ZH-HMC-W Horns / Strobes. Models NS-MC-CR, NS-MC-CW, NS-HMC-CR, NS-HMC-CW, ZH-MC-CR, ZH-MC-CW, ZH-HMC-CR, ZH-HMC-CW are horn / strobes for ceiling mount only. Suffix CR or CW are for ceiling and color. Units are synchronized or non-synchronized strobes. Refer to Listee's data sheet for additional detailed product description and operational RATING: Electrical 16-33VDC/FWR Candela: NS-MC-C, ZH-MC-C = 15/30/75/95 candela NS-HMC-C, ZH-HMC-C = 115 / 177 cd NS-MC, ZH-MC = 15/30/75/110 cd ZH-HMC, = 135 / 185 cd Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical I candela rating and UL label. APPROVAL: Listed as audible and audible II visual signaling devices for use with separately listed electrically compatible fire control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only. All synchronization strobes shall be used with model DSC sync control module (CSFM listing No. 7300-0067:212). Refer to manufacturer's installation manual for details Note: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation ) in accordance with NFPA 72, 2002 Edition. NOTE: 09-07-2007 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to Iistee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0067:0252 Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: James Muha (973) 593-2664 Fax (973) 593-6652 Email: james.muha@siemens.com DESIGN: Models ST-MC-RETRO-R, ZR-MC-W, ZR-MC-R, ZR-HMC-R, ZR-HMC-W intended for indoor use on walls. Models ST-MC-CW, ST-HMC-CW, ZR-MC-CR, ZR-MC-CW, ZR-HMC-CR, and ZR-HMC-CW multi candela intended for indoor use mounted on the ceiling only. Z -series strobes are intended for use with models ZB-R or ZB-W back boxes. ST - series strobes are intended for use with models SHBBS surface back boxes. Model numbers may be followed by alpha characters indicating lens orientation, lettering, and color. Refer to listee's data sheet for additional detailed product description and operating considerations. RATING: Electrical 16-33VDC/FWR Candela: ST-MC-RETRO-R 15cd, 30cd, 75cd, 110cd ZR-MC-W, ZR-MC-R 15cd, 30cd, 75cd, 110cd ZR-MC-CR, ZR-MC-CW 15cd, 30cd, 75cd, 95cd ST-MC-CW 15cd, 30cd, 75cd, 95cd ZR-HMC-R, ZR-HMC-W 135/185cd zR-HMC-CR, ZR-HMC-CW 115/177cd Flash Rate: 60 flashes / minute INSTALLATION: In accordance with Listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -w are wall mount only. Models with suffix -C are ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical / candela rating and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's installation instruction manual for details. NOTE: 9-10-2007mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-0067:0268 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: Siemens Industry, Inc. Building Technologies Division8 Fernwood Road, Florham Park, NJ 07932 Contact: James Muha (973) 593-2664 Fax (973) 593-6652 Email: james.muha@siemens.com DESIGN: Model PAD-4 distributed power module NAC expander monitors the voltage of its two input circuits to determine when to operate its four notification circuits. It provides one AC Fail and one Trouble Relay as well as an auxiliary power circuit. It can also provide up to 9 amps of 24 VOC power and adds two additional Class A circuits by adding the optional PAD-4-CLSA module. The PAD-4 consists of the following: PAD-4-MB; PAD-4 Main Board PAD4-CLSA; Class A Expander Module FP-2011-UI; 170W Power Supply FP-2012-UI; 300W Power Supply Refer to listee's installation/operation manual for additional detailed product description and operational considerations. RATING: 120/240 VAC, 60/50 HZ, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Unit shall be fully supervised and shall have 24 hr. battery back-up. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as a notification circuit expander for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details 08-20-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division