Loading...
HomeMy WebLinkAbout705 PALOMAR AIRPORT RD; 340; FPC2020-0191; Permitcucity of Carlsbad Print Date: 04/08/2021 Job Address: 705 PALOMAR AIRPORT RD, #340, CARLSBAD, CA 92011-1064 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2101001600 Track #: Valuation: $130,786.12 Lot #: Occupancy Group: Project #: DEV2020-0159 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0191 Status: Closed - Finaled Applied: 11/09/2020 Issued: 12/07/2020 Finaled Close Out: 04/08/2021 Inspector: Final Inspection: Project Title: FUTURES ACADEMY AT CARLSBAD Description: FUTURES ACADEMY -INSTALLATION OF NOTIFICATION DEVICES TO CONNECT TO EXISTING NAC POWER SUPPLY FOR THE 3RD FLOOR (11 DEVICES) Applicant: FPContractor: HOFMANN FINN DEVELOPMENT COMPANY IN A D T COMMERCIAL LLC 3188 AIRWAY AVE, # STE A P0 BOX 310702 COSTA MESA, CA 92626-4652 BOCA RATON, FL 33431-0000 (714) 540-4433 (561) 989-7919 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 - Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FIRE ALARM SYSTEM For FUTURES ACADEMY 705 PALOMAR AIRPORT ROAD, SUITE 340 CARLSBAD, CALIFORNIA 92011 w Submitted By: ADT COMMERCIAL 920 South Andreasen Drive, Suite 102, Escondido, California 92029 (760) 233-9787 NOTIFIER® by Honeywell FCPS-24S6 & Series Remote Power Supplies The FCPS-24S6 Series (6-amp) and FCPS-24S8 Series (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Primary applica- tions include notification appliance circuit (NAC) expansion (to sup- port ADA requirements and NAC synchronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 pro- vides regulated and filtered 24 VDC power to four notification appli- ance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-2456/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. The FCPS-2456C and FCPS-2458C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS- 24S8 used in this document refers to the FCPS-24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E. Features UL-Listed NAC synchronization using System Sensor®, Whee- lock®, or Gentex® Commander2" appliances Operates as a sync-follower" or as a 'sync-generator" (default) See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped permanently "ON" (stand-alone mode) Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs 6-amp (FCPS-2456) or 8-amp (FCPS-24S8) full load output, with 3 amps maximum/circuit, in NAC expander mode (UL 864) 4-amp (FCPS-2456) or 6-amp (FCPS-2458) continuous output in stand-alone mode (UL 1481) Compatible with coded inputs; signals passed through Optional power-supervision relay (EOLR-1) In stand-alone mode, output power circuits may be configured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two Fully regulated and filtered power output - optimal for powering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power Power-limiting technology meets tJL power-limiting requirements Form-C normally-closed trouble relay Fully supervised power supply, battery, and NACs Selectable earth fault detection AC trouble report selectable for immediate 2-hour delay Works with virtually any UL 864 fire alarm control which utilizes an industry-standard reverse-polarity notification circuit (including unfiltered and unregulated NAC power) Requires input trigger voltage of 9 - 32 VDC Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.IH x 36.83Wx 6.985D) Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batteries Battery charger may be disabled via DIP switch for applications requiring larger batteries Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire Specifications Primary (AC) Power: FCPS-24S61-2488: 120 VAC, 60 Hz, 3.2A maximum FCPS-24S6C/-24S8C: 120 VAC, 60 Hz, 3.2A maximum FCPS-24S6E/-24S8E: 240 VAC, 50 Hz, 1.6A maximum Wire Size: minimum #14AWG (2.0mm2) with 600 V insulation Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC Trigger Current: 2.0 mA (16 - 32 V); Per Input: 1.0 mA (9 - 16 V) Trouble Contact Rating: 5 A at 24 VDC Auxiliary Power Output: Special application power 500 mA maxi- mum Output Circuits: +24 VDC filtered, regulated 3.0 A maximum for anyone circuit Total continuous current for all outputs (stand-alone mode): - FCPS-24S6: 4.0 A maximum - FCPS-2458: 6.0A maximum Total short-term current for all outputs (NAC expander mode): - FCPS-2456: 6.0 A maximum - FCPS-24S8: 8.0 A maximum Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only Float-charge voltage: 27.6 VDC Maximum current charge: 1.5 A Maximum battery capacity: 18 AH D-6927:A3.11/4/2019—Page 1 of 2 Applications Example I: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appli- ance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24-volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-24S8). Both resettable and non-resettable power options are available. Resettable outputs are created by connecting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance cir- cuits. This typically allows for mounting the FCPS at greater dis- tances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to activate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS pro- vides power to the addressable control module. NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-24S6/-2458 can track (i.e. "follow") the strobe syn- chronization timing pulses on the existing NAC wire run. This main- tains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-24S8 is configured (via DIP switch settings) as a "sync follower," the FCPS' NAC outputs track the strobe syn- chronization pulses present at the FCPS' sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 are configured (via DIP switch set- tings) as a "sync generator," the FCPS' sync input terminals are not used. Rather, the FCPS is the originator of the strobe synchroniza- tion pulses on the FCPS' NAC outputs. In "sync generator" mode, the sync type (System Sensor, Wheelock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-24S6 and FCPS-24S8 comply with the following stan- dards: NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode) UL 1481 Power Supplies for Fire Alarm Systems Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-24S6C & FCPS-2458C) CSFM Approved: 7315-0028:0225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions FCPS-24S6C: Same as above, ULC-listed FCPS-24S6R: Same as FCPS-24S6 with red enclosure FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"Wx 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions FCPS-24S8C: Same as above, ULC-Iisted FCPS-24S8R: Same as FCPS-2458 with red enclosure FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions ZNAC-4: Class A (Style Y) NAC option module EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933) PS-1270: Battery, 12-volt, 7.0AH (two required) Iso ooi C.. C ; dl s.q.l dIIlNS I MANUFAflhIUS QUALITY SYSTEMS This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NO11FIER® and System Sansorrk are registered trademarks of Honeywell N OTI Fl ER International Inc. Wheelock® is a registered trademark of Cooper Technol- 12 Clintonville Road ogies Company. GentealS is a registered trademark at Genteo Corpora- Northford, CT 06472 ion. ©2019 by Honeywell International Inc, All rights reserved. Unauthorized 203.484.7161 use of this document is strictly prohibited, www.notifler.com Country of Origin: USA NOTIFIER® by Honeywell CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7315-0028:022) Page 1 of I CATEGORY: 7315 -- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models FCPS-24S6 andCPS-24S8'are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1 -24-O3KK STi This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Strobe, Horn Strobe, and Horn Notification Appliances Cei Description: The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation** Sleek Modern Aesthetics Finger Slide Switches Voltage Test Points Multiple Voltages 1h4 3 Audible Settings 90, 95, 99 dB 8 Candela Settings Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75195/115/1501177 U Universal Mounting Base Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low current Draw Compatibility and Requirements - Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol - Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models Patented ** Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971, Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (i 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). be Ratinas oer UL Standard 1971 24 VDC /24FWR 1 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 0.253 0.110 0.140 SIC 8.0-33.0 0.061 0.085 0.103 0.135 0.163 0.182 0.205 0.253 0.110 Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current* at Anechoic 99 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current* at Anechoic 95 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 woommommo~~~ UL Max Current* at Anechoii:90i:113A 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 - 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic - Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information -- Sync w/ Model Strobe DSM or 12/24 VDC* Mounting Candela Wheelock Power Options Supplies HSR 15/1575/30/75/95/110/135/185 X X UMB** HSW 15/1575/30/75/95/110/135/185 X X UMB** HSRC 15/30/60/75/95/115/150/177 X X UMB** HSWC 15/30/60/75/95/115/150/177 X X UMB** STR 15/1575/30/75/95/110/135/185 X X UMB** STW 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** CSMD 15/30/60/75/95/115/150/177 X X UMB** HNR X X UMB** HNW X X UMB** HNRC X X UMB** HNWC X X UMB** NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shalt be Wheelock* ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HNAudibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances -UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 Wheelock° tMEDCJ SAFEPATH WAV Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (25-0785:01) Page 1 of I CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models strobe, HS horn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm Tt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Sleek Modern Aesthetics Finger Slide Switches W. *** 8 Candela Settings j Wall - 15/1575/30/75/95/110/135/185 Ceiling - 15/30/60/75/95/115/150/177 Universal Mounting Base I Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw f j Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95, 99 dB Strobe, Horn Strobe, and Horn Notification Appliances f FlRE\ rI I -. -- - Ceiling Wall Description: The Wheelock® ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela settings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed. The UMB allows for consistent installation and easy replacement of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. - Save up to 48% in current draw* -Upto9models now in 1 appliance - Save up to 14% cost of installation** Compatibility and Requirements -Synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol -Compatible with UL "Regulated Voltage" using filtered VDC or unfiltered VRMS input voltage - Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models *** Patented ** Compared to previous models NOTE: All CAUTIONS and WARNINGS are identified by the symbol A All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, I INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range". All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%) UL 464 (85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24VDC UL Max Current* at Anechoic 99 dBA 24VDC 12 VDC Model Regulated 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current* at Anechoic 95 dBA 24VDC 12VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.18 0.230 0.272 0.122 UL Max Current* at Anechoic 90 dBA 24VDC 12 DC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 0.120 0.148 HSC 8.0-33.0 0.065 1 0.084 10.120 0.136 0.157 0.184 0.226 0.267 0.120 Horn Ratings per UL Anechoic Model Regulated Voltage Range VDC 99 dB 95 dB 90 dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 H 8.0-17.5 0.047 1 0.026 1 0.017 HNC 8.0-17.5 1 0.047 10.026 1 0.017 -- * UL max current rating is the maximum RMS current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Sync wl Model Strobe DSM or 12/24 VDC Mounting Candela Wheelock Power Options Supplies l:r1I.1r1.r HSR 15/1575/30/75/95/110/135/185 X X UMB** HSW 15/1575/30/75/95/110/135/185 X X UMB** HSRC 15/30/60/75/95/115/150/177 X X UMB** W- P) 15/30/60/75/95/115/150/177 X X UMB** SW STR 15/1575/30/75/95/110/135/185 X X UMB** ST\N 15/1575/30/75/95/110/135/185 X X UMB** STRC 15/30/60/75/95/115/150/177 X X UMB** C 15/30/60/75/95/115/150/177 X X UMB** VH X X UMB** X UMB** X C EJ X X UMB** HNWC X X UMB** 2 VDC models feature 15 & 15/75 settinas **UMB = Universal Mounting Base NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Architects and Engineers Specifications The notification appliances shall be Wheelock ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and SIC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, Wheelock® Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances -UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM IEPA4 I,fl71.I4 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 Wheelock° (MEDCJ SAFEPATH WAAE!:S~)) Notification CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL 0.; FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. (7125-0785:0168) Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock Inc.7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conover@cooperindustries.com DESIGN: Exceder Series: Models ST strobe,jhorn strobe and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a C may be added for ceiling models and/or a '-NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires CJ u ne 30,i1 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division