Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 125; FPC2019-0261; PermitPERMIT REPORT 4 City of Carlsbad Print Date: 01/19/2022 Permit No: FPC2019-0261 Job Address: 2525 EL CAMINO REAL, # 125, CARLSBAD, CA 92008-1261 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563020900 Track #: Applied: 11/14/2019 Valuation: $39,533.50 Lot #: Issued: 12/03/2019 Occupancy Group: Project #: Finaled Close Out: 02/05/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: POPPING KETTLE -FIRE ALARM TI (ADDRESSABLE, 4 DEVICES) Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov Johnson Johnson Controls 3568 Ruffin Road, South San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Product Submittal Project: Popping Kettle The Shoppes at Carlsbad 2525 El Camino Real Suite 125 Carlsbad, CA 92008 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douplas.daniels(djci.com 11/12/2019 REV.#: 0 PROJECT I, Johnson Controls 3568 Ruffin Road, South Johnson V San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4090-9010 Relay lAM 7300-0026:0311 1 49V0-APPLC Strobe 7125-0026:0373 2 49SV-APPLC Speaker Strobe 7125-0026:0384 11/12/2019 REV.#: 0 PROJECT 7 ®Simplex UL, ULC, CSFM Listed, FM Approved* I11Ii i-..1 Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 i1/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 Ds ri nti c 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Ir1 Model Description (4JJ9O 1 ) 1 8 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 I I For semi-flush I Trim plate, galvanized mounted box steel, with LED viewing I For surface I window; includes 4090-9802 mounted box mounting screws 4090-9813 I Adapter plate to fit 4 (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1, NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4WHx4"Wx1%"D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range I Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © 1 © © Add supplied label I AvERnssaENlI cover on-site if controlling 'em IAvmissar: 4-9/16" 120 or 240 VAC 4-5/16" (116 mm) (109 mm) Light pipe for LED viewing © © © © (116 mm) 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited S.SIMPIEX Tyco Fire Protection Products• Westminster, MA • 01441-0001 • USA S4090-0015-1 11/2014 www.simplex4ire.com 02014 Tyco Fire Protection Products. All rights reserved All specificat.'ons and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay [AM, *4090..9010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Simplex TrueAlert ES Addressable Notification Appliances UL, ULC, CSFM Listed; FM Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Approved Description Ceiling Mount Addressable Visible (V/O) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC Signaling Line circuit (SLc). WO notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. LED and Xenon tube strobes devices are interoperable on the same IDNAC channel. Separate appliance and cover selection greatly simplifies the ordering and installation process. Features Individually addressed Visible Only (V/O) notification appliances Multi-candela LED strobe available in low (15, 30 75 and 110 cd) and high (110, 135 and 185 cd) range candela models. Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators. Advanced addressable notification controlled by IDNAC SLCs. IDNAC SLCs provide regu!0ted29 VDC allowing horns to operate with lower current Electrical test point access by removing the cover Strobe intensity can be programmed from the control panel or the device Wiring supervision to each appliance allows T-tapped connections for Class B circuits to simplify wiring (class A circuits require in/out wiring) Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID, custom label, type, and candela setting Magnet test diagnostics assist checkout and testing of appliances and wiring compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 Synchronized strobe operation on its IDNAC channel. LED Indicator and Magnet Test feature: Indicator LED indicates magnet test acknowledgment, 3 digit IDNAC address, and candela rating Indicator LED can be configured to blink every polling cycle to indicate appliance supervision When the controller is in diagnostic mode, the magnet test pulses the Indicator LED to indicate appliance address and can be set to also briefly flash the strobe LEDs Mechanical design features Rugged, high impact, flame retardant thermoplastic housing in red and white colors Various covers and lettering options available - Red with wite letters or white with red letters covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts on 4" square or single gang USA electrical boxes. Adapter plate required for mounting on single gang electrical boxes. Optional wire guards Weatherproof back boxes are required for surface mounting. Figure 1: Indoor Ceiling Mount Strobe Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling code (NFPA 72), ANSI Al 17.1; the appropriate model building code: BOcA, lcBo, or SBCcl; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. TrueAlert ES Diagnostics Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the appliance's address when a magnet is applied. Operational Appliance Magnet Test In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (ISIT) The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert ES appliances to its ability to test IDcs, NAcs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. * Additional listings may be applicable; Contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Ac49Voc-0001 Rev. 12 3/2019 Simplex Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Installation Reference - (1 [] Appliance with cover (front) Appliance (rear) I I Mount to 4" X 4" X 1-1/2" 'I I electrical box using 8-32 screws Address dip switch 0 Note: ceiling mount only Set device address before fixing cover in place. Candela flag setting Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set Wiring terminals for strobe the flag to the desired connections candela rating. accept #12-18 AWG wires Use slotted screwdriver here to remove cover IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be T-tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1: ceiling Mount Addressable Visual Only V/O Appliances Model* Lens color Description Installation Instructions unaw 49V0-APPLC-BA _......... ......--..----..---. Clear49V0H-APPLC .. ............. ....... VO appliance only. Select cover 579-1227 49V0H-APPLCA Amber separately. 49V0H-APPLCB Blue 49V0H-APPLCG Green 57 9-12 80 49V0H-APPLCR Red Table 2: Surface/WP back boxes Model Color Description Installation instructions 49WPBB-VOCR Red Surface/V/P back box in red 579-1270 49WPBB-VOCW White Surface/WP back box in white Note: Use WP back boxes for surface mounting only. using weatherproof back boxes does not make an appliance weatherproof. Page 2 AC49VOC-0001 Rev. 12 3/2019 SimplEx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Table 3: Adapter plates Model Description Installation Instructions VO Ceiling Mount Adapter Plate. Required for 49V0-APCS mounting on a single gang electrical box. 579-1227 Table 4: WO Covers (Required when ordering APPLC models) Model* Color Wording 49V0C-CRALT 49V0C-CRBF Red ALERT FEU/FIRE 49V0C-CRFEU FEU 49VoC-CRF 49V0C-CRS FIRE Simplex logo only 49V0C-CRBM ,LL(/ALERT 4bcF 5 FiRE 49V0C-CRBAF j-/FlRE 49V0C-CK Black Blank 49V0C-CWALT White ALERT 49V0C-CWBF FEU/FIRE 49V0C-CWFEU FEU 49V0C-CWF FIRE Simplex logo only 49V0C-CWBM LL)/ALERT 49V0C-CWBCF )J/FIRE 49V0C-CWBAF j,'-/FIRE Table 5: Wire Guards Model Description 49WG-VOCR TVO Ceiling Mount Red Wire Guard - 49WGBB-VOCR - IVO Ceiling Mount Wire Guard Back Box Note: * (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6: Compatibility Reference Compatible Controllers SheetData Controller Output IDNAC SLC Output Appliance Voltage Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 4009 6N AC .........IDNAC SLC S4100-0034 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4100ES Flex 35,50, and 100 Amplifiers 4100ES Constant Supervision and Signal Cards Page 3 AC49VOC-0001 Rev. 12 3/2019 £ SimplEx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 TrueAlert ES V/C LEGACY Compatibility Reference Table 7: Compatibility Reference Compatible Controller Data Sheet Reference Controller Output lAvailable Strobe Intensity Appliance Voltage Minimum 41 OOES or 4100U with 54100 0031 TrueAlert Power Supply 4009 TPS, Remote TrueAlert 17 VDC Power Supply* lS4100-0037 TrueAlert Addressable SLC 15, 30, 75, and 110 cd 17 VDC TrueAlert Addressable S4009-0003 Controller (4009T) Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 117 VDC to 31 VDC, Special Application Candela Setting 115 cd 30 cd 75 cd 1110 cd 17 VDC RMS Current Ratings, with horn on continuousat high setting, 73 mA 114 mA 210 mA i269 mA use when connected to lrueAlertAddressable SLCs per above * For connection to legacy fire panel models Simplex 4009T and 4100/IPS. High candela (49V0H) appliances are not compatible with Simplex models 40091 and TPS, see the fire panel compatibility charts. Ceiling Mount V/C Specifications Table 8: Specifications Specification Rating Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two Connections wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Table 9: Percentage of rated light output at room temperature Angle On-Axis Vertical, Below Axis Horizontal, Left/Right of Axis 450 900 1450 900 UL required output 100% f45% 25% 45% 25% Typical output 1327% 134% 83% 129% 47% Table 10: Appliance Specifications Specification -- Rating Operating Voltage Range 23 VDC to 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max 127 SN appliances per IDNAC Loading channel Candela Setting 15 cd 30 cd 75cd 90/95 cd 110 cd 135 cd 185 cd 49V0 model 55 mA 83 mA 153 mA N/A 199 mA N/A N/A Current 49V0H model N/A N/A N/A N/A 253 mA 296 mA 377 mA consumr,tion** 49V0H a m b lens N/A N/A N/A 253 mA (90 cd) 296 mA 377 mA N/A 49V0H blue N/A N/A 253 mA 296 mA (95 cd) 377 mA N/A N/A lens ** Measured at 23VDC on IDNAC Addressable SLC © 2019j0hn50n controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). AC49VOC-0001 Rev. 12 3/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0373 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyettejci.com DESIGN: Model 49AVTrue Alert ES addressable horn/strobes with suffixes WRF, WRF-BA, WNF, WINE-BA, *wRS WRS-BA, WS-BA, *WRQ WRQ-BA and APPLW. Model 49AVTrue Alert ES addressable horn/strobe covers with suffixes WRFIRE,WNFIRE, WRS,WJVS, WRALT, WVALT, WRFEU, WWFEU, WRBLNG, and VWVBLNG. Model 49VOTrue Alert ES addressable strobes with suffixes WRF, WRF-BA, WINE, WINE-BA, *wRS WRS-BA, *\fS WINS-BA, *WRA WRA-BA, *WA WINA-BA, *Q *WRQ ,WRQ-BA, and *..tQ Model 49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, WJVFIRE, WRS, VVWS, WRALT, WNALT, WRFEU, \MNFEU, WRBLNG, and WNBLNG. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 17-31 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a wall mount horn/strobe or strobe for indoor use only. Models require the use of the 4009-9401 TrueAlert NAC extender (CSFM Listing No. 7300-0026:214) or 4100-5120, -5121, -5122 True Alert Power Supples*or 4100-5311, -5313, -5325, 53-27 Extended Power Supplies (CSFM Listing No. 7165-0026:251) *or 4010-9601, -9602, -9603. -9604, -9606, 9701, -9702, 9722 Control Units (CSFM No. 7165-0026:369) or 4007-9201, -9202 Control Units (CSFM No. 7165-0026:378). Refer to listee's Installation Instruction Manual for details. *Rev 09-02-15 gt ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should iot be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 5 SimplEx TrueAlert Addressable Notification Appliances UL, ULC Listed; FM Approved* Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Introduction Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from the Simplex Fire Alarm Control Unit IDNAC Signaling Line Circuit (SLC). Audio is supplied from a separate compatible Simplex Fire Alarm Control Unit audio NAC. Wiring supervision is electronically monitored allowing audio and IDNAC wiring to be T-tapped for Class B wiring, reducing wiring costs and wiring distances. Installation on standard 4 inch square 2 1/8 inch deep USA electrical boxes for flush installations (provided by others) or surface/VIP backboxes (order below) for surface or WP installations. Appliances are available in 400-4000 Hz and 200- 10000 Hz high fidelity models. Separate appliance and cover selection greatly simplifies the ordering and installation process. Model numbers ending in -BA are assembled in the USA. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-0001. Figure 1: Ceiling Mount Addressable SpeakerNisible Notification Appliance Ceiling Mount Addressable Speaker Product Selection Table 1: ceiling Mount Addressable Speaker SN Appliances Model Description Installation Instructions 49sv-I\PPj SN appliance only. Select cover and surface/WP box (if 579-1203 495V-APPLC-BA required) separately. Table 2: High Fidelity Appliances Model Description Installation instructions High Fidelity SN appliance 49HFV-APPLC only. Select cover and 49HFV-APPLC-BA surface/WP box (if required) 579-1 203 separately. Table 3: High candela Appliances Model Description installation instructions High Candela SN appliance 49SVH-APPLC-BA only. Select cover and weatherproof box (if required) 5791203 separately. I Table 4: High Fidelity High candela Appliances 'Description installation KU instructions High Fidelity High Candela 9HFVH-APPLC SN Appliance Only. Select 9HFVH-APPLC-BA 'cover and surface/WP box (if required) separately. Appliance with amber colored FVH-APLCA-BA 1 579-1203 lIens. Select cover and surface! IWP box (if required) separately. i.V Appliance with blue colored FVH-APLCB-BA Hens. Select cover and surface/ :WP box (if required) separately. Table 5: SN covers (Required when ordering APPLC models) SKU Color Wording 49SVC-CRALT Red ALERT 49SVC-CWALT White 49SVC-CRBA 49SVC-CWBA Red White----------- ------- ....------- j,a-/FlRE 49SVC-CRBC Red ). !FIRE ALARM 495VC-CWBC White 49SVC-CRBF Red EU /FIRE 495VC-CWBF White 49SVC-CRFEU I .__ FEU 495VC-CWFEU White 49SVC-CRFIRE Red FIRE 49SVC-CWFIRE White 49SVC-CRS Red Simplex logo only 49SVC-CWS White 49SVC-CK Black No logo or lettering * Additional listings may be applicable; Contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. 5495 VC-0001 Rev. 7 10/2018 Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Weatherproof Product Selection Table 6: Weatherproof Ceiling Mount Addressable SN Appliances SKU Description Installation instructions 49SVH-APPLC-0 iSN Appliance Only. Select cover and surface/WP 495vH-AppLC-Co (Canada only) box separately 579-1241 Table 7: SN Covers (Required when ordering APPLC-O models) SKU Color Wording 49SVC-CRALT-0 Red ALERT 49SVC-CWALT-0 iWhite 49SVC-CRBA-0 lRed j/FlRE 49SVC-CWBA-0 White 49SVC-CRBC-O Red *WFIRE ALARM 49SVC-CWBC-0 White 49SVC-CRBF-O Red FEU/FIRE 49SVC-CWBF-0 White 49SVC-CRFEU-0 Red FEU 49SVC-CWFEU-0 iWhite 49SVC-CRFIRE-0 ....,.....J_.............. !Red 49SVC-CWFIRE-O White FIRE 49SVC-CRS-0 ------..----------------..------4--.------------------..--.----..--------- Red Simplex logo only 49SVC-CWS-0 lWhite 49SVC-CK-0 iBlack Table 8: Surface/WP Back Boxes SKU Color Description Installation instructions 49WPBB-SVCR iRed Surface/WP back box in Red 5791240 49WPBB-SVCW White Surface/WP back box in White Table 9: Wire Guards and Wire Guard Back Boxes SKU Description 49WGBB-SVCR-0 49WG-SVWCR Wire Guard Back Box, Ceiling, Red, WP Wire Guard, Ceiling, Red Ceiling Mount SN Specifications Table 10: Appliance General Specifications Specification Rating Dimensions 8 1/8" H x 7 1/8W x 3"_D(206mm_x 180mm x76mm) ___________________ Environmental 32° to 1200 F (0° to 49° C); 10% to 93%, non-condensing at 1040 F (40° C) Connections ITerminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. Table 11: Speaker Audio Specifications Specification Rating Input Voltage 1250r70.7Vrms Power Taps 1/4, ½, 1, and 2 W Frequency Response 400 to 4000 Hz (SN, SNH), 200 to 10000 Hz (H/F, eneral Signaling = 125 to 12 kHz Table 12: Speaker Output Ratings Wattage Tap ¼ W i ½ W 1 W 2W Model SN H/F SN H/F SN H/F SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 79 76 83 80 186* 184 189, 1871 Anechoic Chamber Test, per ULC-5541 (dBA)* 79 78 8382 86* 85* 89* 88* * Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-5541 Anechoic Chamber Testing) Attenuation -3 dB 170° jAngle Attenuation -6 dB Angle 80° Page 2 S49SVC-0001 Rev. 7 10/2018 SimplEx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Table 13: Percentage of rated light :On-Axis Vertical, Below Axis Horizontal, Left Right of Axis Angle :oe 450 900 450 900 UL required output 100% 5% 251/16 45% 25% Typical output 327% 134% 83% 129% 47% Table 14: IDNAC SIC Specifications Specification Rating Typical Operating Voltage Range 23 voc to 30 VDC, Special Application Appliance voltage design reference 23VDC (with 6VDC drop) Supervisory Requirements 1 unit load (= 0.8 mA control unit current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max 127 SN appliances per IDNAC channel Maximum of 127 addresses per SLC, 139 unit loads. See device and IDNAC SLC Loading compatible Fire control Unit Installation Instructions for circuit current load limits. UTP, unshielded twisted pair recommended IDNAC SLC Wiring Specifications (refer to control unit installation Maximum wire length allowed with '7-Taps" for class B wiring per SLC = instructions for more information) 10000 ft (3048 m) Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Table IS: Current consumption** Candela Setting 15 c 30 c 75 c 110 c 1135d 185 c 49SV and 49HFV 59 mA 82 mA 145 mA 193 mA N/A N/A models -.-.----.--- --- -- T-; 325 mA Weatherproof SV N/A N/A 320 mA 360 mA N/A 400 mA appliances I ** Measured at 23VDC on IDNAC Addressable SLC Speakers are for connection to compatible fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. Table 16: Equipment Compatibility References Compatible Equipment Data Sheet Reference 41 GOES with EPS+ or EPS Power Supply 54100-0100 4009 IDNAC Repeater 54009-0004 4100ES Flex 35 and 50 Watt Amplifiers 4100ES 100 Watt Amplifiers S4100-0034 41 DOES constant Supervision and Signal cards Page 3 S49SVC-0001 Rev. 7 10/2018 SimpIEx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Ceiling Mount SN Installation Reference Appliance with cover (front) Mount to 4" X 4"X 2-1/8" Magnet test location electrical box using 8-32 indicated by area that screws / 0 is not textured . Note: Ceiling mount only 93 00,0000 00%0000 0 '000000 00000 0 004 I V ool00000o%008o00000000 - I 00G000QQ00Q000O00%00 NX I 00G 000000 Appliance test points,P oo.0000000000000000000000oo000000000o.00 Il 000000000000000000000S0O audio circuit power taps, ' %%t%%%%%8000000 and address dip switch :1009 0 0%0 S OQSOOØOO 00000 0%00.OQ Set audio circuit power taps and . 00 device address before fixing 0o.040oo:0 eo0 0 _a0 0 cover in place. Wiring terminals for speaker Candela flag setting : : : and strobe connections Set flag to FACP to control : : : : accept 2 #12-18 AWG wires candela rating from an FACP providing IDNAC notification. To set candela manually, set ,' 110 the flag to the desired :75 30 candela rating. is Use slotted screwdriver cp , ___- here to remove cover. , I w rr Figure 2: Installation reference I? © 2018j0hnson Controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). S49SVC-0001 Rev. 7 10/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 1 M4~- LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimpIex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,495V-APPLC-BA,49H FV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA49SVH-APPLC,49HFVH-APPLC,495V-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49sVAppLw0 *49SVAPPLW0BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Johnson #1 Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com Contractor's License Detail for License # 986047 Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2021 This license is current and active. All information below should be reviewed. F1lt1[.]l dO - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Bond ofQuahfyrng Individual This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/20180 Workers' Compensation I This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC313943 - Effective Date: 10/01/2018 Expire Date: 10/01/2020 Workers' Compensation History Other Personnel listed on this license (current or disassociated) are listed on other licenses. 10/11/2019 REV.#: 0 PROJECT #: 480- Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com 10/11/2019 REV.#: 0 PROJECT #: 480-