HomeMy WebLinkAbout5770 FLEET ST; ; FPC2021-0065; PermitPERMIT REPORT 4L-City of Carlsbad Print Date: 08/09/2021 Job Address: 5770 FLEET ST, CARLSBAD, CA 92008-4700 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2111000200 Track #: Valuation: $1,137,309.03 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Project Title: Description: JENNY CRAIG -SPRINKLER TI (1 HEAD) Permit No: FPC2021-0065 Status: Closed - Finaled Applied: 04/28/2021 Issued: 04/28/2021 Finaled Close Out: 08/09/2021 Inspector: Final Inspection: Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC KELLY SANTOS 9925 PROSPECT AVE, #STE B 9925 PROSPECT AVE, #STE B SANTEE, CA 92071 SANTEE, CA 92071-4376-SAN DIEGO (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 6 heads or less $125.00 Total Fees: $125.00 Total Payments To Date: $125.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FPc2o2J - tq a Fire Protection Products Worldwide I Contacts www.tyco-fire.com Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) 1Y313 .......Upright 5.6K, 1/2NPT TY323 ......Pendent 5.6K, 1/2NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/barll2) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200° F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame .................... Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 TFPI72 Page 2 of 4 Components: - * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON CROSS SECTION 1 7/16 (11,1 mm) I NOMINAL MAKE-IN 2' (50,8 mm) _______ 1/2" NPT** UPRIGHT \ - (50,8 mm) 3/8" (34, 1- J- 9 mm) DEFLECTOR * PENDENT WF 2-7/8' (73,0 mm) DIA. RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT 'TY313) AND PENDENT 'TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W- TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. - 2-7/8 DIA. - (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) I MOUNTING 1/8 J SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4 FLUSH MOUNTING 8" J (7,9±6,4 mm) 1/2 (12,7 mm) SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER I TEMPERATURE I FINISH J- ] RATINGS SIN 1 NATURAL BRASS I 370 I 5.6K UPRIGHT (1/2 NPT) TY313 PURE WHITE (RAL9010)°° POLYESTER 371 5.6K PENDENT (1/2NP TY323 POLYESTER SIGNAL WHITE (RAL9003) 175 175-F (79-C) Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I ** Eastern Hemisphere sales only TABLE A - SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F(57°C) 155 155°F (68°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products r . C'AIA LiD G V ., Do ull Moose Tube® is a customer focused, o growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. www.BullMooseTube.com sales@bullmoosetube.com 800.325.4467 2 Bull Moose Tubes7 'Eddy Pipe7" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASIM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MIC preventative coating. Bull Moose Tube" sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MIC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube* resumes the right to change product specifications without notice and without incurring obligation. APPROVED no A. MOM NFPX Moose Tube's® Schedule Bull SCHEDULE 10 PIPE SPECIFICATIONS 10 and Schedule 40 are FM Approved and UL listed (for U.S. NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE and Canada), even though these SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE products do not require separate approvals and listings. Bull 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 Moose Tubes made the decision 1-1/4 1.660 1.442 9.91 - 1.81 lbs/ft 2.518 - 61 to have them approved and listed. 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 Our Schedule 10 and Schedule 40 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 have a pressure rating of 300 PSI 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 and have been through the same 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 rigorous testing as our other fine 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 pipe products. Schedule 10 can be supplied roll grooved or plain end. SCHEDULE 40 PIPE SPECIFICATIONS Bull Moose Tube's Schedule 10 and Schedule 40 pipes are hot NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE dipped galvanized to meet ASTM SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE Al 23 standards. All products are stencilled to meet FM & UL 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 specifications. 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 - - 2 - - 2.375 2.067 1.00 3.661bs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3 3500 3.068 100 758 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 'Only available in Casa Grande, AZ -Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVED NFPA •---' PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masurp OH 63017 Dull Moose Tube's® Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® U is a lightweight replacement for Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion Has a pressure rating of 300 Psi. Resistance Ratio of 1. Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1-1/4 ' 1.650 1.418 1.00 1-1/2 1.900 1.654 - 1.00 2 - 2.375 2.123 1.00 *corrosion Resistance Ratio per latest UL Directory Listing 1.461 1.860 70 2.070 - 2.754 51 2.547 3.468 44 3.308 ' 4.842 30 c®ujs LISTED PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROV13) no 4 q 1 W: 5 A NFPK -- For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, DC Masury OH 63017 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2'. Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM Al 35 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVm (;]4q4 NFPA 6 ADVANTAGES OF BULL MOOSE TUBE® EODYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight th.xn Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UI UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U i nit Clarkson Road Chesterfield, MO Gerald, MO Kent,wA Casa Grande, AZ Dallas D( Masury, OH 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW I.) is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD 1111 MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, NIPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flows® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE an opportunity for downsizing 1-1/4 1.660 1.530 1.98 1.222 2.019 61 and further cost savings. 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 21/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.5Ô0 4.310 - 1.00 4.968 11.290 19 'corrosion Resistance Ratio per latest Lit. Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED <*> APPROVED 0 N FS A NFPA -- ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO On= Casa Grande, AZ Dallas, TX Masury, OH 63017 7 Dull Moose Tubes® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I) a versatile product that can be • Certified to ASTM Al 35 and A795 Type F, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight -saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedules approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WE SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 - 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1:00 1.604 3.344 - 37 * Pressfit is a Registered Trademark of Victaulic company of America Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED reovm (a A MINIMA B PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 - www.bullmoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, TX Masur6 OH aas,enjsEpa.ny 63017 c®us LISTED NPS(IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 0.0(m) 1.315 1.660 1.900 2.375 ID (in) - 1.201 1.546 1.786 2.261 ULTRA EDDVe Weight (Ib/ftr' 0.868 1.107 1.274 1.604 Water-Filled Weight(Ib/ft) 1.359 1.920 2.360 3.344 2.17 1.40 1.11 1.00 1'0D (in) 1.660-- 1.900 2.375 r 2.875 3.500 4.500 1.0(m) 1.530 1.728 2.203 2.705 3.334 4.310 [EDDY LE(flptyWe1ghtb#t) -- 1.222 - 1.844 2.330 2.809 1 3.361 4.968 Wáter-FilledWeight(lb/ft( 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 - ao.(mn - 1.315 1.660 1.900 2.375 2.875 3.500 4.500 1.0(m) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE EmptyWeight(lh/ft 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Wa ter Filled Weight(lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R.' 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.315 1.660 1.990 2.375 [ID(in) 1.137 1.482 1.712 2.177 - - EEDDYLITE-L ErnptyWerght(mb/ft) - 1.260 1.617 1.967 2.617 ter-Filled Weight (I W) 1.700 2.364 2.965 4.230 FCRR 013 008 012 -0.16- O.D. (in) 1.295 1.650 1.900 2.375 EDDYTHREAD ID (10)1 1.083 1.418 1.645 2.123 4Q [Empty Weight(lh/ft[' 1.461 2.070 2.547 3.308 Water-FiRed Weight (lb/ftp 1.860 2.754 3.468 4.842 CRR_ 100 100 100 100 [ öD (in) f315- 1.660' 1 90O 2375 2.875 3.560 4.506 -1.0,4,9 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE [1weight(lb/ft 1.680- 2270 2720 3.660 5.800 7.580 10.800 40 WaterFilledWeight(lb/lt) 2055 2918 3602 5 114 7875 10783 16.316 T.ôo :. :1.00:: o - 1.00 i.00 A A For Additional Information Contact (800) 325-4467 www.bul!moosetubecom Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ DallntD( Masuiy OH 63017 9 APFROVEO 14M] A-- MINIM NFPA -- ULTRA EDDY 0.868 91 rSCHEDULE10- 1.410 91 IEDDYLITE 1.260 91 1.461 70 '-SCHEDULE 40- 1.680 70 rULTRAEDDY 1.107 61 EDDY FLOW 1.222 61 SCHEDULE 1O 1.810 61 [DDYLITE° ' 1.617 61 rEDDYTHREAD 4007 2.070 51 SCHEDULE40 2.270 51 ULTRAEDDY 1.274 61 EDDYFLOW ] 1.844 61 'kREDUILE-f0_7 2.090 61 rEDDYLITE 1.967 61 ibDYTHREAD40®1 2 547 44 SCHEDULE 40 2.720 44 :.ULTRAEDUYa 1.604 37 EDDY FLOW 2.330 37 SCHEDULE 1O 2.640 - 37 EDDYLITE 2.617 37 JD W14 3.308 30 ?IEDULE1 3.660 30 - EDDY FLOWS 2.809 SCHEDULE0 1 3.530 30 SCHEDULE4O j 5.800 EDDYFLOW 3.361 CHEDULE.10 4.340 19 [7-kH-EDOUE 4b;7.590 EDDY FLOW* 4.968 iscHEpvIiii 5.620 19 EDULE40r1 10.800 -SCHEDULE 10_ 9.289 10 SCHEDULE 1O 16.940 7 1,659 1,896 1,975 2,695 3,079 3,208 2,408 2,752 2,867 2,148 2,454 2,557 2,470 2,822 2,940 1,418 1,621 1,688 1,565 1,789 1,864 2,319 2,650 2,760 2,071 2,367 2,466 - 2,217 2,534 2,639 2,431 - 2,778 2,894 1,632 1,865 1,943 2,362 2,700 2,812 2,677 3.060 3,187 2,520 2,880 3,000 2,353 2,690 2,802 2,513 2,872 2,992 1,246 1,424 1,484 - 1,810 - -- 2,069 - 2,155 - 2,051 2,344 2,442 - 2,033 2,324 2,421 2,084 2,382 2,481 2,306 2,635 2,745 1,770 2,022 2,107 2,224 2,542 2,648 3,654 4,176 4,350 1,341 1,533 1.596 - - 1,732 1,979 2,062 -. 3,024 3,456 3,601 1,982 2,265 2,360 2,242 2,563 2,670 4,309 4,925 5,130 1,951 2,229 2,322 2,490 2,846 2,965 1-1/4 1-112 c®us LISTED 2-1/2 APPROVED otam 4 10 Only Available in Casa Grande, AZ. - NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 1 0.50 0.75 1.00 1.25 1.50 1.75 1 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1 1012 1 867 1 726 40 40 1 40 1 40 1 40 1 37 34 32 1 30 29 28 1 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. F25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 c®us LISTED <> APPROVED (;] 44 NFPA' For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas TX Masury, OH 63017 11 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED BMT EDDY PIPE® BRAND SPRINKLER PIPE IS PRODUCED AT OUR GERALD, MO., CASA GRANDE, AZ. AND MASURY, OH. PLANTS WITH ADDITIONAL STOCKING LOCATIONS IN DALLAS, TX. AND KENT, WA. FOR ADDITIONAL INFORMATION CONTACT YOUR SALESPERSON TODAY AT: (800) 325-4467 OR FROM CANADA CALL: (BOO) 882-4666 STOCKING LOCATION c®us LISTED 4, ONFSA MANUFACTURING PLANT! APPROVEO _._ MW *STOCKING LOCATION APPRGV ( A_NFPA -* I] lleable Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature Pressure ____________ Class 150 Class 250 Class 300 (°F) (°C) psi b ps bar psi bar -200 -28.90 IL to to 300 2c.7 503 34.5 600 41.4 1500 65.60 2000 93.30 265 1.3 455 31.4 550 379 2500 121.10 225 IE.5 405 27.9 505 348 3000 148.90 185 12.E 360 24.8 460 31.7 3500 176.70 150 102 3115 21.7 415 28.6 4000 204.40 110 75 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 10 12.4 280 19.3 5500 287.8° - - 130 9.0 1 230 15. Note: Unions with Copper or Copper Atop sean are not intended 1r use where temperature exceeds 450°F c®us APPROVED For Listings/Approval Details and Limitations, visit our website @ www.anvilintl.com or contact an Anvil/AnviISt3r Sales Representat ye. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes ¼-i" (6-25 mm) Sizes 11/4"-2" (32-51 mm) Sizes 21/2 -3' (64-76 mmt si bar psi bar psi bar psi bar -20° -289' to to 00 150° 65.6° 2,000 137.9 1,500 103.4 1,000 69.9 2000 93.3 1 265 i&3 j 1,785 123.1 1,350 93.1 910 62. 253° 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 303° 143.9 185 12.9 1,360 93.8 1,050 72.4 735 50.7 350° 178.7 150 10.3 1,150 79.3 900 62.1 650 44.8 400° 204.4 - 935 64.5 750 51.7 560 38.6 450° 232.2 - - 725 50.0 600 41.4 475 22.8 50 C 260.0 0 - - 510 35.2 450 31.0 385 26.5 550' 287.8 - - 300 20.7 j 300 20.7 300 20.7 ALL ELBOWS&TEES ' ':0 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. 16.9 bar) C) 0 0 E U, -) 0 E 0 Aivi' Class l5O,'3C0 v'alleable Iron Fittings conform to ASME 86.3 and Uiicns :jnform to ASME B16.39. cc Cj - PF-11.10 tqccs Worldwide i Fire Protection Contacts www.tyco-flre.com Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi1/2 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 WF Fl 2-7/8" (73,0 mm) DIA. TFPI72 Page 2 of 4 4 - Bulb 5 - Compression Screw Components: 1 - Frame 2 - Button 3 - Sealing Assembly * Temperature rating is ** Pipe thread connections per ISO 7-1 indicated on Deflector, can be provided on special request. ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) NPT** NOMINAL MAKE-IN 6 - Deflector* DEFLECTOR* SEATING SURFACE STYLE 15or20 RECESSED ESCUTCHEON 1 7/16 (11,1mm) NOMINAL MAKE-IN 2" (50,8 mm) 1/2' NPT** \) (50,8 mm) ,, 1-3/8 (34 9 mm) DEFLECTOR * CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE_______ Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135'F (57'C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. ^WRENCH RECESS / (USE ONLY FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. - 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. ?_ FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH 3/8±5/16 (9,5±7,9 mm) MOUNTING \ 1/8 SURFACE (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4 (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) (7,9±6,4 mm) 1/2(12,7 mm) FLUSH !1/ ____ MOUNTING / CLFM 1/8' J SURFACE// (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPI72 Page 4 of 4 P/N*77_XXX_X_XXX I I SPRINKLER I TEMPERATURE I FINISH I RATINGS SIN 1 NATURAL BRASS I370 I 5.6K UPRIGHT (1/2NPT) 1Y313 3 PURE WHITE (RAL9010)°° POLYESTER 371 5.6K PENDENT (1/2 NP TY323 POLYESTER SIGNAL WHITE (RAL9003) 175 175-F (79-C) * Use suffix "I" for ISO 7-1 connection; 9 CHROME PLATED for example, 77-370-4-175-I - ** Eastern Hemisphere sales only TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 135 135°F (57°C) 155 155°F (68°C) 200 200°F (93°C) 286 286°F (141°C) Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber(P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, PIN (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products Full Line Sch-40 Replacement Dyna-Thread® sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-f it applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Dyna-Thread is approved for standard hanger spacing (15 ft. D.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. American Made Able to meet "Buy American" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread pipe is manufactured to meet: ASTM A 135, Type E Grade A, and is in compliance with NFPA-1 3. All sizes of Dyna- Thread are rated at 300 psi working pressure. Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread can be "hot-dip" galvanized* to meet FM requirement for dry systems. Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). ThI7 ead Specifications NPS Nominal I.D. Wt. Wt. (H20 Filled) CRR CRR In; mm In; mm Lbs/Ft; kg/rn Lbs/Ft kg/rn Unthreaded Threaded 1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 - - 1¼" 1.408 1.870 2.54 9.50 1.00 32 35.8 2.8 3.78 - - 1½" 1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 479 - - 2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 - - APPROVEb * Must be ordered in 10 bundle increments. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: tciallied TUBE & CONDUIT Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com 161005 Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place Harvey, IL60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 @2009-10 Tyco mt., All Rights Reserved, STP-S3-4-NON-1 003 STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 34, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the 00 of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals ro-7j, MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date . Approved Date www.victaulic.com VIcTAuLIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTALIC COMPANY. ALL RIGHTS RESERVED. REV_G Para \4taulicr 10.52_i IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 wig 1L 1 1A 1A 13M 1.30 1.83 1.10 3.87 . 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 13M 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 j 32.5 46.5 27.9 98.3 65.0 0.50 1 13M 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 1 38.6 1.42 55.4 1.95 t -- .. - 27.9 1.22 98.3 4.08 65.0 1 2.56 0.54 1.2 11/2 x 112 40 15 30.2 36.1 j 49.5 31.0 103.6 65.0 0.54 1.2 3/4 1 3A6 1.40 1.95 1.22 4.08 2.56 20 30.2 35.6 , 49.5 31.0 103.6 65.0 0.54 1 1 3A6 1.64 2,30 1.22 4.08 2.56 1.3 25 30.2 1 3A 41.7 1.66 58.4 2.19 31.0 1.46 103.6 4.60 65.0 2.56 0.59 1.3 2 x ½ 50 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 3/4 1 136 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 , 41.7 55.6 37.1 116.8 65,0 0.64 1 13/16 1.88 2.54 1.46 4.60 2.56 1.5 25 - 30.2 1 3A6 47.8 1.91 645J 2.44 371 1.71 1168 5.40 65.0 2.56 0.68 1.6 21/2 x 1/2 65 15 30.2 48.5 - - 62.0 43.4 137.2 65.0 0.73 3K 1 3A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 i/rn 'T 2,13 2.79 1.71 2.56 1,6 5.40 25 30.2 13/16 54.1 1.91 70.9 - 2,44 43.4 . 1,71 137.2 5.50 , 65.0 2.56 , 073 1.6 ½ 76.1 mm X 15 30.2 48.5 62.0 414 139.7 65.0 9.7__ 2.56 1.6 3/4 1 ,16 1.89 2.44 ' 1.71 5.50 20 30.2 , 48.0 62.0 43.4 139.7 65.0 0.73 2.79 1.71 5.50 1 1,16 2.13 2.56 1 1,7 25 30.2 54.1 70.9 43.4 139.7 65.0 I 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS II. •11 I, 'f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product Failure to verify suitability in advance may result in assembly problems or leakage. Center o run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com viclAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIc COMPANY. ALL RIGHTS RESERVED. 1O.52_2 vJtauIic REV_G IPS CARBON STEEL PIPE HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com -N Ac--ta—uhlcf VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 10.52_3 STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to ciange product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV UPDATED 12/2009 ictaUl-id vICTAULIC IS REGISTERED TRADEMARK OF vICTAULIC COMPANY. 0 2000 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEELICPVC 112&314 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - 203-EX 25511 '1 - 8" .c$ Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H- 171 E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES- * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPAI3 PIPE ROD lOOt 5801+259 UL TEST LOAD 1 318 30.75 403.75 750 11/4 3(6 43.95 469.75 750 11/2 3/8 54.15 520.75 750 2 3/6 76.95 1 634.75 750 21/2 3/8 118.35 841.75 850 3 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 PIPE A I B C -i- 1 1.8793 2.5259 1114 2.1382 2.7850 1112 2.2673 2.9149 B 2 2.0048 3.2516 A 2112 3649M 4.1150 3 3.7845 11 4 4,3582 4.9M 6 6.0468 8.8180 8 7.5768 8.3260 L1 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c • us 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to lost of business or profit, when non-AFCON products have been, or are used. L1 1/08 Not less than 2' nominal width Wood Flooring - - Product Features Nopre-drillingrequired. Not lesothan Quick to install using the Sammy 3' nominal Nut Driver with an 18V cordless thickneso (2-112') drill/ddver(depth or side 4,heet of verbcal member) Saves time from traditional Dou methods. _________ rie5lIqr 4fra Reduces installation cost. Made in the U.S.A. _ Qum ma ft IIffi •• 1/4 8002957 GST 100 1/4 x 1" 210 (7/160SB) 25 125 1/4' 8003957 GST 200 1/4o2' 1760 (Fir) - 25 125 ir ----1[4"-8004957 GST 300 1/4x3 2060 (Fir) -- - 25 125 3/8' 8006957 GST.75 1/4x3/4' 564 (3/4' Ply) 25 125 .- - - 210 7/16"OSB - - - 3/8' 8007957 GST 10 1/4 x 300 25 125 670 (3/4" Ply) qL 3/8 8008957 GS 20 1/4x2 - 1760 (Fir) - 850 1475 25 125 3/8 8068925 GST 2O-SS1/4x2 1760 (Fir) 850 25 125) 3/8' 8009925 GST2S-380 3/8x2-112" 2113 (Fir) 1500 25 125 #14 Black 3O 3/8 8010957 GST - 1/4x 2O r) 15001475 25 125] J t Driver 8069925 - GST 30-SS - 1/4x3' 2060 (Fir) - 25 i. Part#8113910 3/8' -- 8011925 -- GST4O 1/4x4" 2180 (Fir) - -- 25 - 1251 3/8" 8012925 GST 60 1/4 x 6' 2230 (Fir) 25 125 - 1/2 8013925 GST2 - 114x2 1760(Ar) 25 125 j 1/2' 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 V2 8015925 03 - 1/4x3 2275 (Frr) 1/2' 8016925 GST4 1/4x4' 2180 (Fir) 25 125 1/2 8017925 - GST6 1/4x6 2230 (Fir) - 25 125 #14SWRed Nut Driver Part # 8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3%' x 12 pitch roof. • Reduces installation cost. Allows 17° deflection from vertical. • Made in the U.S.A. ___ 3J' SH-GST2O 1/4x2" 1257 (f ir) .19P? 1050 1475 25 11 3/8' 8141957 SH-GST30 1/4x3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part # 8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ri Not less than 2" nominal width Product Features It -1121up to 3-117 pipe; not boo than No pre-drilling required. 3' (2-1/2") nominal width 4' & 5' Floor Joist . Quick to install using the Sammy Minimum 2-1/2" from bottom for Nut Driver with an 18V cordless branch lines. Minimum 2" from bottom for main toes. Exception: This drill/driver. / requirement shall not apply to 2' or - / thicker nailing strips resting on top of steel beams Saves time from traditional methods. Reduces installation cost. 'Made in the U.S.A. J- vue2wnirzitMi H #14 SW Red Nut Driver Part # 8114910 Namm OMMD 1/4' 8018957 - SWG 100 1/4xr 622 (Fir) 25 125 1/4" 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 3/8 8020957 SWG 10 1/4 xl 622 (Fir) 300 25 125 3/8' 8021957 SWG 20 1/4 x 2" 1725 (Fir) 1050 25 125 -f 3/8 ä673925 - SWG 20 SS 1/4 x 2 1725 (Fir) 850 25 125 lI, 3/8" 8022925 SWG 25-380 318x2-112" 2249 (Fir) 1500 25 125 3/8 8023925 SWG 30 1/4 x 3 1884 (Fir) - 25 125 INSTALLATION STEPS -1jjI INTO WOOD & STEEL: IiNSTALLATION STEPS WOOD & STEELI Insert the appropriate nut driver into a 3/8" or 1t2" portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2° or metric all thread rod, boll stock. (The 1/2" requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel, Insert the appropriate nut driver into a 3/8° or 112" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or boll stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlln steel SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue Oiling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.