HomeMy WebLinkAbout2077 LAS PALMAS DR; ; FPC2021-0075; PermitPERMIT REPORT (_Cityof Carlsbad Print Date: 07/15/2021 Permit No: FPC2021-0075 Job Address: 2077 LAS PALMAS DR, CARLSBAD, CA 92011-1519 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel U: 2130611800 Track U: Applied: 05/11/2021 Valuation: $118,437.60 Lot U: Issued: 05/25/2021 Occupancy Group: Project U: Finaled Close Out: 07/15/2021 #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Inspector: Plan Check U: Final Inspection: Project Title: / Description: SYMBIENT - SPRINKLER TI (31 HEADS) Applicant: FPContractor: AMERICAN AUTOMATIC FIRE SUPPRESSION AMERICAN AUTOMATIC FIRE SUPPRESSION INC INC KELLY SANTOS 9925 PROSPECT AVE, U STE B 9925 PROSPECT AVE, U STE B SANTEE, CA 92071 SANTEE, CA 92071-4376-SAN DIEGO (619) 562-3010 (619) 562-3010 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov tqcul F/re & Building Products Technical Services: Tel: (800)381-9312/ Fax: (800) 791-5500 Series ELO-231B - 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage - General Description The 11.2 K-factor, Series EL0-231 B, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are "standard response - spray sprin- klers" that produce a hemispherical water distribution pattern below the deflector. The 11.2 K-factor, ELO-231B Sprin- klers were subjected to full scale, high- piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor stand- ard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231B Sprinklers - making their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO-231B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. sentative of all possible corrosive at- mospheres. Consequently, it is recom- mended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The ef- fects of ambient temperature, concen- tration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive na- ture of the chemical to which the sprin- klers will be exposed. An upright intermediate level version of the Series ELO-231B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231 B Up- right Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231B Sprinklers can be obtained by utiliz- ing the Series ELO-231B Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series ELO-231B Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series ELO-231B Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler's Approvals and/or Listings. Pagel of ill MARCH, 2007 TFP342 Page 2 of 6 TFP342 SPRINKLER FINISH TYPE TEMPERATURE BULB LIQUID NATURAL BRASS I CHROME PLATED LEAD COATED I WAX COATED I WAX J OVER LEAD UPRIGHT (TY5151 & TY5851) 155°F/68°C Red 1,2,3,4 3 200°F193°C Green 286°F/141°C Blue 3 f 3(a) PENDENT (1Y5251 155°F/68°C Red 1,2,3,4 3 200°F193°C Green 286°F/141°C Blue 3(8) NOTES: Listed by Underwriters Laboratories, Inc. (UL Listed). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL Listed). Approved by Factory Mutual Research Corporation (FM Approved). Approved by the City of New York under MEA 291-04-E. (a). FM Approved for a maximum ceiling temperature of 150°F/66"C. TABLE A LABORATORY LISTINGS AND APPROVALS FOR 11.2 K-FACTOR SERIES ELO-2318 UPRIGHT AND PENDENT SPRINKLERS (Refer to the Design Criteria Section) Model/Sprinkler Identification Numbers TY5151 - Upright 11.21K, 3/4NPT TY5251 - Pendent 11.2K, 3/4"NPT TY5851 - Upright 11.2K, 1/2"NPT TY5151 is redesignation for C5151. TY5251 is a redesignation for C5251, G1871, and S2531. 1Y5851 is a redesignation for C5851. Technical Data Approvals UL and C-UL Listed. FM and NYC Ap- proved. (Refer to Table A for complete approval information including corro- sion resistant status. The approvals apply to the service conditions indi- cated in the Design Criteria section.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 11.2 GPM/psi112 (161,4 LPM/bar112) Temperature Ratings Refer to Table A Finishes Refer to Table A Physical Characteristics Frame .............Bronze Cap ..............Bronze Sealing Assembly ........... Beryllium Nickel w/Teflont Bulb (5 mm dia.) .......Glass Compression Screw .....Bronze Deflector ............Bronze t Registered trademark of DuPont. Design Criteria UL and C-UL Listing Requirements The 11.2 K-factor, Model ELO-231B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with NFPA 13 standard sprinkler posi- tion and area/density flow calculation requirements for light, ordinary, or ex- tra hazard occupancies, as well as high piled storage occupancies (solid piled, palletized, rack storage, bin box, and shelf storage including but not lim- ited to Class I-IV and Group A plastics) with a minimum residual (flowing) pressure of 7 psi (0,5 bar) for wet or dry pipe systems. FM Approval Requirements The 11.2 K-factor, Model ELO-231B (TY5151, TY5251 & TY5851) Sprin- klers are to be installed in accordance with the applicable "control mode den- sity/area" guidelines provided by Fac- tory Mutual. (FM guidelines may differ from UL and C-UL Listing criteria.) 1/2(12,7mm) NOMINAL MAKE-IN TFP342 Page 3 of 6 * Temperature rating is indicated on deflector. ** Pipe thread connections per ISO 7/1 can be provided on special request. 2-13/16" (71,4 mm) JNPT WRENCH i-vs LATS 20 L 7/16 (11,1 mm) NOMINAL MAKE-IN 1/2" (12,7 mm) NOMINAL MAKE-IN 3/4** NPT RELIEF PT Components: 1 - Frame 2 - Seal : Assembly 3-Cap 4-Bulb 5- Compression :' 6 - Screw Deflector * UPRIGHT UPRIGHT PENDENT CROSS TY5851 TY5151 TY5251 SECTION FIGURE 1 11.2 K-FACTOR SERIES ELO.231B UPRIGHT - 3/4" NPT (TY5151), UPRIGHT - 1/2" NPT (TY5851), AND PENDENT - 3/4" NPT (TY5251) SPRINKLERS Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Installation The Series ELO-2318 Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°F/68"C to 3/32 inch (2,4 mm) for the 2860F/1410C temperature ratings. A leak tight 3/4 inch NPT sprinkler joint should be obtained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maxi- mum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT connections. A leak tight 1/2 inch NPT sprinkler joint should be ob- tained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maximum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series ELO-231B Upright and Pendent Sprinklers must be installed in accordance with the following in- structions. Step 1. Pendent sprinklers are to be "FITTING SIDE" TOWARDS SPRINKLER FITTING / WRENCH RECESS (END "A-) FIGURE 2 W-TYPE 3 SPRINKLER WRENCH installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 3 Sprinkler Wrench (Ref. Figure 2), except that an 8 or 10 inch adjustable Crescent wrench is to be used for wax coated sprinklers. With reference to Figure 1, the W-Type 3 Sprinkler Wrench or the adjustable Crescent wrench, as applicable is to be applied to the wrench flats. When installing wax coated sprinklers with the adjustable Crescent wrench, additional care needs to be exercised to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of Page 4 of 6 TFP342 bare metal to the corrosive environ- ment. The jaws of the wrench should be opened sufficiently wide to pass over the wrench flats without damag- ing the wax coating. Before wrench tightening the sprinkler, the jaws of the wrench are to be adjusted to just con- tact the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. After installation, the sprinkler wrench fiats and frame arms must be in- spected and the wax coating re- touched (repaired) whenever the coat- ing has been damaged and bare metal is exposed. The wax coating on the wrench flats can be retouched by gen- tly applying a heated 1/8 inch diameter steel rod to the areas of wax that have been damaged, to smooth it back over areas where bare metal is exposed. NOTES Only retouching of the wax coating ap- plied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precautions need to be taken, when handling the heated rod, in order to prevent the installer from being burned. If attempts to retouch the wax coating with complete coverage are unsuc- cessful, additional wax can be ordered in the form of a wax stick (the end of which is color coded). Only the correct color coded wax is to be used, and retouching of wrench flats and frame arms is only permitted at the time of initial sprinkler installation. With the steel rod heated as previously de- scribed, touch the rod to the area re- quiring additional wax with the rod an- gled downward, and then touch the wax stick to the rod approximately one-half inch away from the area re- quiring retouching. The wax will melt and run down onto the sprinkler. Care and Maintenance Series ELO-231B Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system control valve for maintenance work on the fire protection system that it con- trols, permission to shut down the af- fected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb (ref. Installation Section Note). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the long term potential integrity of the sprinkler coatings. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national code. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. SPRINKLER TEMPERATURE RATING 1 NATURAL BRASS 9 CHROME PLATED 155 155°F/68°C 6 WAX COATED 200 200°F/93°C 7 LEAD COATED 286 286°F/141°C 8 WAX OVER LEAD TYPE 510 UPRIGHT 3/4' NPT (TY5 151) 512 PENDENT 3/4' NPT (1Y5251) 501 UPRIGHT 112" NPT (TY5851) TFP342 Page 5 of 6 Ordering P/N 50-XXX-X-XXX Procedure A Part Number (PIN) is not specified when ordering sprinklers with thread connections per ISO 7/1. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connection: Specify: (specify SIN), 11.2 K-factor, (specify temperature rating), Series ELO-231 B Standard Response (spec- ify Pendent or Upright) Sprinkler with (specify finish), P/N (specify from Ta- ble B). Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001. Wax Sticks: (for retouching wrench damaged wax coating) Specify: (Specify color) color coded Wax Stick for retouching (specify tem- perature rating) temperature rated Se- ries ELO-231B Sprinklers, PIN (spec- ify). Red for 155°F .............P/N 56-065-1-155 Blue for 200°F and 286°F ................. P/N 56-065-1-286 NOTES Each wax stick is suitable for retouch- ing up totwenty-five sprinklers. The wax used for 286°F sprinklers is the same as for 200°F sprinklers, and, therefore, the 286°F sprinkler is limited to the same maximum ceiling tempera- ture as the 200°F sprinkler (i.e., 150°F). TABLE B PRODUCT SYMBOL NUMBER SELECTION 11.2 K-FACTOR SERIES ELO-2318 STANDARD RESPONSE UPRIGHT AND PENDENT SPRINKLERS Page 6 of 6 TFP342 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 'tqccs Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2" NPT TY323 ......Pendent 5.6K, 1/2" NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* *The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/ps1112 (80,6 LPM/bar112) FEBRUARY 2014 Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly .........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze TFPI72 WF Fl 2-7/8" (73,0 mm) DlA. —...-] TFPI72 Page 2 of Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - I efIector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON CROSS SECTION 1 7/16 (11,1mm) I NOMINAL MAKE-IN 2 (50,5 mm) 1/2 NPT** UPRIGHT \TJ= (50,8 mm) , 1-3/8" (34 9 mm) DEFLECTOR * PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT 'TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum to maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pen- dent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. / WRENCH RECESS / (USE ONLY END FIGURE 2 W- TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprin- kler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and fin- ishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leak- ing or exhibiting visible signs of corro- sion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/ slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any other authorities hav- ing jurisdiction. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. 2-7/8 DIA. (73,0 mm) - 2-1/4" DIA. FACE OF (57,2 mm) SPRINKLER FITTING (9,5±7,9 mm) . 5/8' (15,9 mm) \ -r ___________ _____________ FLUSH 3/8±5/16" I ___ I MOUNTING \ 1/8 _____ mm) SURFACE ______ CLOSURE SERIES MOUNTING 1-3/8' (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4' DIA. FITTING (57,2 mm) (7,9±6,4 mm) \ _____________ FLUSH 5/16±1/4" 1/2' (12,7 mm) _ - I--I MOUNTING 1/8" J SURFACE/K \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY 'TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON TFPf72 Page 4 of 4 P/N* 77 - XXX - X - XXX I SPRINKLER TEMPERATURE FINISH RATINGS SIN 370 5.6K UPRIGHT (1/2 NPT) TY313 371 5.6K PENDENT (1/2 NPT) TY323 Use suffix "I" for ISO 7-1 connection; 1 NATURAL BRASS 3 PURE WHITE (RAL9010)** POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 9 CHROME PLATED for example, 77-370-4-175-I Eastern Hemisphere sales only 135 135-F (57-C) 155 155°F(68°C) 175 175-F (79-C) 200 200'F (93-C) 286 286F (14C) TABLE A SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Num- ber (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pen- dent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) tem- perature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutcheon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright© 2014 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is trademark of The DuPont Corporation. Fire Protection Products I Malleable Iron Threaded Pipe Unions Pressure - Temperature Ratings Temperature ___ Pressure Class 150 Class 250 Class 300 (°F) (°C) psi bar psi bar psi bar 200 to 1500 -28.9° to 300 20.7 65.60 500 34.5 600 41.4 2000 93.30 265 18.3 455 31.4 550 37.9 2500 121.10 225 15.5 405 27.9 505 34.8 3000 148.90 185 12.8 360 24.8 460 31.7 3500 176.70 150 10.3 315 21.7 415 28.6 4000 204.40 110 7.6 270 18.6 370 25.5 4500 232.20 75 5.2 225 15.5 325 22.4 5000 260.00 - - 180 12.4 280 19.3 5500 28780 - - 130 9.0 230 15.9 Note: Unions with Copper or Copper Alloy seats are not intended for use where temperature exceeds 450°F c®us APPROVED For Listings/Approval Details and Limitations, visit our website © www.anvilintl.com or contact an Anvil/AnvilStar Sales Representative. Malleable Iron Threaded Fittings Pressure - Temperature Ratings Temperature Pressure Class 150 Class 300 __________ Sizes '/1-1 (6-25 mm) Sizes 1%-2 (32-51 mm) Sizes 2/2"3 (64-76 mm) (° (°C) psi bar psi bar psi bar psi bar -200 -28.90 to to 150° 65.6° 300 20.7 2,000 1379 1,500 103.4 1,000 68.9 2000 93.3 265 18.3 1,785 123.1 1,350 93.1 910 62.7 2500 121.1 225 15.5 1,575 108.6 1,200 82.7 825 56.9 3000 148.9 185 12.8 1,360 93.8 1,050 72.4 735 50.7 3500 176.7 150 10.3 1,150 79.3 900 62.1 650 44.8 4000 204.4 - - 935 64.5 750 51.7 560 38.6 4500 232.2 - - 725 50.0 600 41.4 475 32.8 500° PROM - - 510 35.2 450 31.0 385 26.5 ALL ELBOWS & TEES ¼' (10 ON) and LARGER ARE 100% GAS TESTED AT A MINIMUM OF 100 PSI. (6.9 bar) 5500 2878 - - 300 20.7 300 20.7 300 20.7 Anvil Class 150/300 Malleable Iron Fittings conform to ASME B16.3 and Unions conform to ASME B16.39. Ca w.anvilintl.com 17- 921111a][1111= a best sprinkler p1 in the industry! CUS LISTED <*> APPROVED no 4 ONFSA NFPA BULL IV100SE TUBE COMPANY c®us LISTED APPROVED Do A ONFSA NFPK YA Bull Moose Tube® is a customer focused, growth oriented manufacturer and marketer of tubular products, where success is based on a commitment to meeting the customer's perception of quality. Our strength resides in our people working together to satisfy customers and to promote business growth by achieving superior financial performance. ULE • www.BuIIMooseTubecom sales@bullmoosetube.com 800.325.4467 !THREAD MY FLOWO BULL MOOSE TUBE COMPANY 2 Bull Moose Tube's® "Eddy Pipe®" brand sprinkler pipe is produced to meet sprinkler pipe standards and applications. c®us LISTED <S> APPROVED no A A.6-NFPA ADVANTAGES OF BULL MOOSE TUBE® EDDY PIPE® FAMILY All pipe products are UL Listed (for U.S. and Canada), and have been approved by Factory Mutual. Excellent production and coating capabilities, tighter tolerances, and our unique steel properties make our pipe excellent for roll grooving, welding, threading, and plain end fittings. All products are certified to ASTM Al 35 and A795 Type E, Grade A. Available in specific cut to order lengths from regular mill rollings. More popular sizes available with coating or bare. Ultra Eddy®, Eddy Flow®, Eddylite®, and Eddythread 40® offer cost savings along with superior hydraulics without compromising service life. Sprinkler pipe inventory stocked in Masury, Ohio; Gerald, Missouri; Casa Grande, Arizona; Kent, Washington; and Dallas, Texas. All Bull Moose (black) sprinkler pipe includes our exclusive EDDY GUARD Il® MlC preventative coating. Bull Moose Tube® sprinkler pipe is FBCTM compatible. PRODUCTS Schedule 10 and Schedule 40: FM approved and UL listed sprinkler pipe. Eddythread 40®: Light threadable Schedule 40 replacement with corrosion resistance ratio of 1.0. Eddylite®: Lightwall threadable with standard outside diameter. Eddy Flow®: Cost effective replacement for Schedule 10. Ultra Eddy®: Lightwall roll groovable pipe. Bull Moose galvanized steel sprinkler pipe is hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. PROTECTION Eddy Guard Il®: Bull Moose Tube® is producing product that can resist bacteriological growth even after multiple rinse-outs. You know MlC corrosion can impact your installation and your property. Specify Bull Moose Tube® "Eddy Guard Il®" and feel comfortable knowing that you are getting Eddy Pipe® product you trust with the bacteria resistance you need. Eddy Guard Il® is NFPA 13 and NFPA 13R system compatible for use in hybrid systems as well as FM approved. All information contained herein is accurate as known at the time of publication. Bull Moose Tube' reserves the right to change product specifications without notice and without incurring obligation. Bull Moose Tube's® Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tube® made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED <> APPROVED Do4 ONFSA NFPA ri SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1.315 1.097 15.27 1.41 lbs/ft 1.820 - 91 11/471 660 ( f442 [ .9 1== f1I6/fF11 2 518 1 r61 ] 1-1/2 1.900 - 1.682 7.76 2.09 lbs/ft 3.053 - 61 - 2 r-nT-:i EThjTIJ 1 264 lbff 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 L _3 3500 260 Ti !FT 7-95 1TTITT1 4 500 4260 250 5621bs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 [ i17 I i660 Wfl L 100 1 8j__T 1 lb/ 602 EIITI z1Ti E: -.E67 L1 00 1 3ibs/ff] [ 51T4fl 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 r TTT1 LiT T II i_111fl7 5ftT [iO7ä3 I 4* r 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 *only available in Casa Grande, AZ **Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bullrnoosetube.com Nn Or From Canada Call (800) 882-4666 sales@bullrnoosetube corn 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grand AZ Dallas, TX Masury, OH BUU_ MOOSE ThEE cOMPAIIV 63017 Dull Moose Tube's® Eddythread 40® ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® I.) is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDYTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR* LB./FT WEIGHT SIZE 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2.375 ' 2.123 1.00 3.3O8 4.842 30 *Corrosion Resistance Ratio per latest UL Directory listing c®us LISTED <9> APPROVED [41 4 -_ NFPA PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak tight scat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 0 For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH 63017 5 Bull Moose Tube's® Eddylite® is a lightwall threadable pipe manufactured in NPS 1" through 2". Eddylite® is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED <> APPROVED I]4 NFPA 6 ADVANTAGES OF BULL MOOSE TUBES EDDYLITE® Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM A135 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 *Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leaktight scat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A <'® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grands, AZ DaIlasD( Masur OH 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® I.) is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow chararterictirs UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD H® MIC preventative coating. economical to use than Schedule 10 due to reduced delivery costs - and ease of handling. Furthermore, NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FT. WT. SIZE an opportunity for downsizing and further cost savings.1 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1/2 1 900 1'.728 3.44 1.844 2.860 61 - 2 2.375 2.203 2.78 2.330 3.982 37 2 1/2 2 875 2 705 - 1 66 28O9 —5299- 30 3 3.500 3.334 1.00 3.361 7.144 19 4 45O0 4310 100 4968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak tight scat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED <> APPROVED cil 4 ONFSA NFPA' ® For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com - 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masutç OH 63017 7 BDull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber ga5keted fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY® - :- - WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 * 1 1/4 - 1 660 1.546' 1.4o 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 1 2 375 2.261 - 100 1 604 - 3 344 37 * Pressfit is Registered Trademark of Victaulic Company of America ** Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVED NFPA 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U; 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grande, AZ Dallas, TX Masury, OH EULLMOOBEflJ coIwAIIv 63017 NPS(IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 c®us LISTED APPROVED /4ONFSA Amt4c.,. Fl,. NPPA O.D.(in) 1.315 1.660 1.900 2.375 1.201 1.546 1.786 2.261 ULTRA EDDY EmWeigI(lb/ft)j 0.868 1,107 1.274 1.604 Water-FilledWeight(lb/ft)' 1.359 1.920 2.360 3.344 2.17 1.40 1.11 1.00 OD(in) 1.660 1.900 2.375 2.875 3.500 4.500 I.D.(in) 1.530 -1.728 2.203 2 705 3.334 4.310 Empty Weight (lb/ft) 1 222 1 844 - 2 330 2 809 3 361 4968 EDDY FLOW Water Filled Weight (lb/ft 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R.198 344 278 166 100 100 1.315 1.660 1.900 2.375 2.875 3.500 4.500 - I.D. -1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE 10 Emr'ieight(lb/ft 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Water-filled Weight b/ft)' 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 0.D.On) 1.315 1.660 1.900 2.375 - LD.(in) 1.137 1.482 1.712 2.177 - EDDYLITE® Empty Weight (Ib/ft) 1.260 1.617 1.967 2.617 Water FilledWeight(lb/ft)r -11 306 ---'.--2.364 2.96S 4.230 r CRR 0.13 0.08 0.1 2 - 0.16 - 0Dn)i 1.295 1.650 1.900 2.375 ID (in) 1.083 1.418 1.645 2.123 EDDYTHREAD Empty Weight (Ib/ft)1 1.461 2.070 2.547 3.308 400 Water AIled Weight (Ib/ft 1.860 2.754 3.468 4.842 - C.R.R. 1 1.00 1.00 1.00 1.00 OD (in) ] 1315 1.660 1900 2375 2.875 3.500 4.500 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE Empty Weight 1.680 2.270 2.720 3.660 5.800 - 7.580 10.800 Water.FilledWeight(Ib/ff) 2.055 . 2.918 - 3.602 5.114 7.875 10.783 16.316 C.R.R. - 1.00 1.00 1.00 1.00 1.00 1.00 1.00 For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ DaIIas lx Masury, OH BULL M(= pgy 63017 9 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY® 0.868 91 1,659 1,896 1,975 SCHEDULE101 1.410 91 2,695 3,079 3,208 1 EDDYLlTE® 1.260 91 2,408 2,752 2,867 EDDYTH11EAD400 ' 1.461 70 2,148 2,454 2,557 'SCHEDULE40 J ULTRA EDDY® 1.680 1.107 70 61 2,470 1,418 2,822 1,621 2,940 1,688 EDDY FLOW® fl 1.222 61 1 565 - 1,789 - 1 864 r SCHEDULE 10 1.810 61 2,319 2,650 2,760 1-1/4 EDDYLITE® 1.617 61 2,071 2,367 2,466 EDDYTHREAD406 ' 2.070 51 2217 2,534 2,639 SCHEDULE 40 ULTRA EDDYO 2.270 1.274 51 61 2,431 1,632 2,778 1,865 2,894 1,943 _EDDY I'Lip"s 1.844 61 2,362 2,700 2,812 SCHEDULE 10 2.090 61 2,677 3,060 3,187 11/2 'EDDYLITE®1 1967 61 2520 2,880 3,000 DDYTHREAD408 2.547 44 2,353 2,690 2,802 SCHEDuLE40' ruL1KALL'u ® 2.720 1.604 44 37 2,513 1,2-16 2,872 r 1.424 2,992 1.484 EDDYFLOW® 2.330 r 1810 2,069 - 2,155 SCHEDULE 10 2640 -37 L 2 05 1 2,344 - 1442 2 EDDYLITEO 2.617 37 2033 2,324 - - 2421 EDDYTHREAD 4O®j 3.308 30 2 084 2 382 2,481 SCHEDULE-40_1'' EDDYFLOW_J 3 660- 2.809 30 - 2306 1,770 2635 2,022 2,745 2,107 2-1/2 SCHEDULE10 3.530 30 2,224 2,542 2,648 SCHEDULE 40* 5.800 3,654 4,176 4,350 EDDY FLOW® 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4340 19 1,732 1,979 2,062 SCHEDULE 40* EDDY FLOW® - 7.580 4.968 3,024 1,982 3,456 2,265 3,601 2,360 4 'SCHEDULE 10 5.620 19 2,242 2,563 2,670 SCHEDULE 4o SCHEDULE 10 - ScHEDuLE 10 AZ. 10.800 9.289 16.940 10 7 4,309 1,951 2,490 4,925 2,229 2,846 5,130 2,322 2,965 6 8 * Only Available in Casa Grande, c®us LISTED <> APPROVED I] APJ,FSA NFPA 10 Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 1 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 1/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 1 531 1 455 1 381 40 40 1 40 1 40 1 37 1 34 1 31 1 29 1 28 1 26 1 25 24 4 1544 1235 1 1012 1 867 1 7261 40 40 1 40 1 40 1 40 1 37 1 34 1 32 1 30 1 29 1 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE7-05) & Cp for NFPA-1 3 shown in BOLD TYPE Pipe Transverse Brace Spacing* Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 1 2.00 2.25 2.50 12.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 i 1/4 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <> APPROVED no /AONFSA *m.S,Ffr. NFPA A For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com J 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, DC Masurç OH MCOI.IPAIW 63017 11 BMT EDDY PIPE® BRAND SPRINKLER PIPE IS PRODUCED AT OUR GERALD, MO., CASA GRANDE, AZ. AND MASURY, OH.. PLANTS WITH ADDITIONAL STOCKING LOCATIONS IN DALLAS, TX. AND KENT, WA. BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <g> APPROVED no A ONFM NFPX FOR ADDITIONAL INFORMATION CONTACT YOUR SALESPERSON TODAY AT: (800) 325-4467 OR FROM CANADA CALL: (800) 882-4666 c®us LISTED /4 (;] ONFSA APPROVED STOCKING LOCATION A, MANUFACTURING PLANT/ STOCKING LOCATION Dyna-T'hreaa specifications NPS Nominal I.D. Wt. Wt. (1120 Filled) CRR CRR In; mm In; mm Lbs/Ft kg/rn Lbs/Ft kg/m Unthreaded Threaded 1.080 1.330 1.75 11.39 1.00 25 27.4 2.0 2.60 - - 11/4 1.870 2.54 9.50 1.00 32 35.8 1 2.8 3.78 - - 1½' 1.639 2.290 3.22 9.14 1.00 40 41.6 3.4 4.79 - . - 2.104 3.050 4.57 8.41 1.00 50 53.4 4.5 6.80 - - 0C 0 APPROVED Full Line Sch-40 Replacement Dyna-Thread® sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. Comparison to L.W.T. Pipe More wall thickness at the thread (CRR= 1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Dyna-Thread is approved for standard hanger spacing (15 ft. aC.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. American Made Able to meet "BuyAmerican" requirements, and is available through distributors in the USA, Canada, Mexico and Latin America. Specifications & Approvals Dyna-Thread pipe is manufactured to meet: ASTMA 135,Type E Grade A, and is in compliance with NFPA-13.All sizes of Dyna- Thread are rated at 300 psi working pressure. Dyna-Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Dyna-Thread can be "hot-dip" galvanized* to meet FM requirement for dry systems. Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). * Must be ordered in 10 bundle increments. Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: Cl i a Customer Service (800) 882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com e • 16100 S Lathrop Ave. • 11350 Norcom Rd. • 2525 N 27th Ave. • 600 Dean Sievers Place TUBE & CONDUIT Harvey, IL 60426 Philadelphia, PA 19154 Phoenix, AZ 85009 Morrisville, PA 19067 02009-10 Tyco Int., All Rights Reserved, STP-S3-4-NON-1003 FireLock® Outlet-T ®<&> ILPCBI SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25 mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 114 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location - Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV G X.A_C_tS_1U1iC~ 1.0.52 1 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1U.Z Nominal Size- :Hole wo 1¼ ½ 1/l6 1.30 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46.5 27.9 98.3 65.0 0.45 3/4 1346 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 65.0 0.50 1 1 3/ 1.52 2.18 1.10 3.87 2.56 1.2 25 30.2 38.6 55.4 27.9 98.3 65.0 1 0.54 1/2 1/2 1 1,42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 49.5 31.0 103.6 65.0 4 0.54 3/4 1 /I6 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13A6 1.64 2,30 1.22 4.08 2.56 1.3 25 30.2 41.7 58.4 31.0 103.6 65.0 0.59 - 2 1h 13/16 1.66 2.19 1.46 4.60 2.56 1.3 50 X 15 30.2 42.2 55.6 37.1 116.8 65.0 0.59 34 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 * 1 1 /6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 47.8 64.5 37.1 116.8 65.0 0.68 - 21/2 ½ 13/16 1.91 2.44 1.71 5.40 2.56 1.6 x 65 15 30.2 48.5 62.0 43.4 137.2 65.0 0.73 3% 13A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48,0 62.0 43.4 137.2 65.0 0.73 1 13A6 2,13 2.79 1.71 5.40 2.56 1.6 25 30.2 54.1 70.9 43.4 137.2 650 0.73 1/2 13A6 1.91 2.44 1.71 5.50 2.56 16 76.1 mm X 15 30.2 1 48.5 62.0 43.4 139.7 65.0 0.73 3% 11/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 1 62.0 43.4 139.7 65.0 0.73 1 13A6 2.13 1 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0.80 FireLock® Outlet-I STYLE 922 DIMENSIONS l;•I I_I • t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 30.52 2 JtauIic REV G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS FireLock® Outlet-I STYLE 922 PERFORMANCE Run Size I)hi/mm x Outlet Size Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT FIiiters 40 25 .1. 65 25 * Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. X, A—C —ta _U, i C~ RFV ( 10.F2 FireLock® Outlet-I STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 6 UPDATED 12/2009 Ai—c—ta—ulic~ VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 vIcTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEL/CPVC II2&314 Inch pipe 5 thru 8 inch pipe SIZE - ROD- 3/8" or 1/2" SIZE - SYSTEM PIPE - 1/2" thru 8" MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - c®Us UBTED 203-EX 25511"- 8" Approval guide - 1"- 8" OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H-171E, Type 10. Manufacturers Standardization Society ANSI/MSS-SP-58 Type 10. MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component of an AFCON hanger. To support steel, CPVC or copper pipe. INSTALLATION - Per NFPA 13, 13R, 13D, these instructions and the CPVC or copper pipe manufacturers instructions. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring. ORDERING - Part #, pipe size. 11/09 NFPA 13 PIPE ROD I WT. 5 WT.-250 UL TEST LOAD 1 318 3075 40375 750 1 1/4 3/8 43.95 469.75 750 11/2 3/6 54.15 520.75 750 2 3/8 76.95 634.75 750 2 1/2 3/8 118.35 841.75 850 3 1 3/8 162.30 1061.50 1050 4 3/8 246.00 1480.00 1500 5 1/2 349.45 1996.75 2000 6 1/2 476.35 2631.75 2650 8 1/2 711.00 3805.00 4050 Restraint SIZE - One size fits 3/4 thru 2 inch AFCON #300 Ring Hanger. 551 FAc!n P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - Sus 203-EX 2551 Listed only for use with AFCON #300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA 13 and CPVC manufacturers instructions on steel, CPVC, or copper pipe. Snap into locking position on swivel nut of AFCON #300 Ring Hanger. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. 'S. r Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting ino listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of basiness or profit, when non-AFCON products have been, or are used. 1/08 n U A Not less than 2 nominal width Wood - onng Product Features "No pre-drilling required, Notlessthan Quick to install using the Sammy thickness (2-1/2") 1W.od Nut Driver with an 18V cordless (depth or side of vertical member) ist .. drill/driver. Saves time from traditional I Doable Sheelrock methods. Ceiling I Reduces installation cost. Made in the USA 'COW 1/4' 8002957 GST 100 1/4 x1" 25 125 1/4" 8003957 GST 200 1/4x2" 1760 (Fir) 25 125 #14 Black Nut Driver 1/4" 8004957 SF _300__-'1 14 x 3" 2060 (Fir) 25 125 1 3/8" 8006957 GST .75 1/4x 3/4" 564 (3/4" Ply) 25 125 3/8 8007957 GST 10 1/4 x1" 300 25 125 3/8" 8008957 GST 20 1/4 x 2" 1760 (Fir) 850 1475 25 125 3/8 8068925 GST 20 SS 1/4"x 2 1760i) 850 25 125 ] YL 3/8' 8009925 GST 25-380 3/8 x 2-1/2' 2113 (Fir) 1500 25 125 318 8010957 GST 30 1/413L 2060 (Fir) 1500 1475 25 i2] 3/8" 8069925 GST 30-SS 1/4x 3" 2060 (Fir) 25 125 Part# 8113910 L 3' 8011925 GST 40 1/4x4" 2180 .,(Er), 25 125 3/8" 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 1/2" 8013925 GST2 1/4x 2" 1760 (Fir) 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 1/2 81925 GST3 1/4x3 2275 (Fir) 25 125 1 1/2" 8016925 GST4 1/4x4" 2180 (Fir) 25 125 #14 SW Red I 1/2" 8017925 ST 6 1/4 x6" 2230 (Fir) - 25 125 Nut Driver Part #8114910 Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. Accommodates up to 3 34" x 12 pitch roof. • Reduces installation cost. Allows 17" deflection from vertical, • Made in the U.S.A. SH-G' 1257 (Fir) 1050 1475 25 12jJ 3/8" 8141957 SH-GSTJO 1/4x3" 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature Which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. I 7-77 Not less than 2" nominal width Product Features (1-1/2)upto3.1/2'pipe; not less than I .,. No pre-dnlllng required. 3'(2-1/2') nominal width 4" & 5" pipe 4 J7T7TA 1' Floor Joist Quick to install using the Sammy Minimum 2-1/2' from bottom for branch lines Minimum 3" from - Nut Driver with an 18V cordless bottom for mainlines. Exception: This drill/driver. requirement shall not apply to 2" or thicker nailing se/ps resting on top of - steel beams. Saves time from tradihonal -, methods. ' Reduces installation cost IL Made in the USA LEI— #14 SW Red Nut Driver Part #8114910 ULTe!t C1I DuonsII Loa -My IL,: 8018957 SWG !1h1I 114" -25 125 1/4' 8019957 SWG 200 1/4 x 2" 1725 (Fir) 25 125 30 8020957 jQ 1/4x1' _-622, 30P 25 125 3/8° 8021957 SWG 20 1/4x2" 1725 (Fir) 1050 25 125 3/8" 8073925 SWG 20-SS 1/4x2 1725 (Fir) 850 25 125 3/8° 8022925 SWG 25-380 3/8 x 2-1/2' 2249 (Fir) 1500 25 125 R° ttfl23 SW( 31) 1/4x3 1884 (Fir) 25 125 I I ISALLAT STEPS j'INTO WOOC & STEEj ETA7L7LATION'STEPS-. INTO WOOD & STEEL] Insert the appropriate nut driver into a 3/8° or 1/2° portable drill Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. When the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4', 3/8°, 1/2' or metric all thread rod, bolt stock. (The 1/2' requires the #14S W red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. Insert the appropriate nut driver into a 3/8' or 1/2'poitable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins free on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4°, 3/8" or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in puriin steel. SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations.