HomeMy WebLinkAbout3447 MADISON ST | 3449 MADISON ST; ; FPR2018-0031; PermitPERMIT REPORT (_City of Carlsbad Print Date: 01/25/2022 Permit No: FPR2018-0031 Job Address: 3447 & 3449 MADISON ST, CARLSBAD, CA Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Single Family Fire Sprinkl Parcel 4*: 2041720500 Track 4*: Applied: 01/18/2018 Valuation: $320,717.00 Lot U: Issued: 02/21/2018 Occupancy Group: Project 4*: Finaled Close Out: 12/09/2020 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check 4*: Inspector: Plan Check 4*: Final Inspection: Project Title: Description: WORTHING RESIDENCE -SPRINKLER 13D (SFD) & ATTACHED 2DU Applicant: DON RILEY 4203 GENESEE AVE, 4* STE 103-424 SAN DIEGO, CA 92117-4950 (760) 917-9058 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $132.00 Total Fees: $492.00 Total Payments To Date: $492.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ALPHA FIRE PROTECTION RESIDENTIAL FIRE SPRINKLER SYSTEM DATA BLOCK: DATE:11712018 JOB ADDRESS: 3447 & 3449 MADISON STREET CARLSBAD, CA. ASSESSOR'S PARCEL NUMBER: 204-172-04 OWNER'S NAME: BROOKS WORTHING OWNER'S PHONE NUMBER: GENERAL CONTRACTOR'S NAME: BH WORTHING GENERAL CONTRACTOR'S PHONE NUMBER: SPRINKLER CONTRACTOR'S NAME: ALPHA FIRE PROTECTION SPRINKLER CONTRACTOR'S ADDRESS: 4203 GENESEE AVE #103-424 SAN DIEGO, CA 92117 SPRINKLER CONTRACTOR'S PHONE NUMBER: (760) 917-9058 CELL CALIFORNIA STATE LICENSE #582853 EXPIRES 12-31-2017 HYDRAULIC NOTES: WATER METER SIZE: 3/4" WATER METER (DUAL WITH DOMESTIC) PRESSURE AT METER: 89PSI METER ELEVATION: 56' AMSL FROM: CHRIS GLASSON @CITv' OF CARLSBAD ENGINEERING DEPT. FLOW (GPM): 39 MAX.GPM DATE: 1-7-18 PHONE- (760) 602-2784 PAD ELEVATION: 56' AMSL PRESSURE AT PAD: 87 PSI PIPE LENGTH: METER To PAD: 25 (+-) Pipe Type/Size: PVC —11/2" SPRINKLER TABLE: SYMB COMPANY & MODEL ORF TYPE TEMP K-FAT CANOPY QTY Tyco LF-II 1/2 SSP 160 Degree 4.9 White Concealed 23 Sin#_TY-3536 o Tyco TY-FRB 1/2 SSP 200 Degree 5.6 White Recessed 5 Sin#TY-323 TOTAL 28 PIPE TABLE: TYPE MFG MODEL AREA OF USE CPVC TYCO BLAZEMASTER 7SYSTEM STEEL BULLMOOSE EDDY-THREAD SCHEDULE 30/40 RISER COPPER MULLER TYPES- M, L & K SUPPLY PVC SPEARS SCHEDULE 40 SUPPLY NOTE: PIPE MUST BE U.L. OR F.M. LISTED FOR RESIDENTIAL FIRE SPRINKLER USE. PLANS MUST STATE: "PIPE WILL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS." "A COPY OF PIPE MANUFACTURER'S INSTALLATION INSTRUCTION PAMPHLET MUST BE KEPT ON-SITE." COpYlight 2016 Natlensi Fire Protection Association (NFPA). Licensed, by agreement for IndtviduaI use and download on August 4,2016 to Dennis Grubb Ascot for designated user Dennis Grubis. No other reproduction or lransmlsslon in any fonn permitted without written permission of NFPA. For inquiries or to report unautho1zed use, contact flcenslng@nlpa.org. This NFCSS All Access subscription expires on January 11. 2017. 13-262 INSTAllATION OF SPRINKLER SYSTEMS Job name. If / $I12(/t# CE sheet nnmber_____ PIPE INFORMATION INFORMATION Node 1 Fator Nominal Fittings—L quantio length ft (as)Factor total (Ps) Notes Met (P13 P ft (and as) fort (m) IjPer (pal) (bar) .1ev (1's) Node 2 — — Total flow (Q) Actual ID Tft (as) ii ç t49 Z4 sv ; ay r8 3 /50 7tcW ,gi - rY q I r,6 179 6' Z 2-2- 0 iO.3 5, z 77L 2- tO 3 +31 O S IL JP1 2 5O -,1gq ( 57 . Z.O4 V'L.C(, 4P '" i•' iq.00 5P J,)MMI1( &W 7.5 ' 13. iM1 1 2- pl.e 2.5 Q ci ' tfig , cfi.. 2 © 2015 NatIonal Fire Protection Association NFPA13 FIGURE 23.3.5.1.2(d) DetaIled Wedsheet. 2016 EdItion copyilght 2016 Na8onaf Fire Protection Association (NFPA). Ucensed. byagTeemenl for Individual use and download on August 4 2016 to Dennis Grubb Assoc for designaled user Dennis Grubb. No other reproduction or transmission In any form pernrttted without written pennisslon of NFPA. For Inquiries or to report unauthorIzed use, contact flcanslng@nfpa.org. Ibis NFCSS All Access subscription expires on Janualyil. 2017. 13-262 INSTALlATION OF SPRNKLERSS!STEMS Job name: 10 C/L)c- f, (l5) PIPE INFORMATION Sheet number: /' OP '1 mum rI NOME MEMMMMM MWOM EMME M MEMEMMM ME= MMEMM = EEMM~M= MMEM MEMM M MEMMMMM MMN= mmmo MEMMMMM mm = MEMMMM = p © 2015 National Fire Protection Association NF 13 FIGURE 23.3.5.1.2(d) Detailed Worksheet. 2016 EdItion Copyright 2016 National Five Ptotedlon Asaodallon (NFPA). Licensed, by agreement, for lndMdual use and download on August 4.201 6 t o D e n n i s ( 3 r u b b A s s o c f o r G e s t g n a l e o u s e r u e n n r s u r u . n u v.urn esnantsslon In any form permitted wfthoutwritten permission OtNFPA. For inquiries or to report unauthorized use, contact llcenaing@nf p a o r g . l i d s N F C S S A l l A c c e s s s u b s c r i p t i o n e s p i r e s o n J a n u a r y 1 1 , 2 D 1 7 - 13-262 INSTALLATION OFSPRRSMS Job name: LJo,vtt íQ Sheet nuinber2 2- rn%iO Ptk.2 /x 1/, $/'ñcfZ. ,,_ 7—I g' PIPE INFORMATION Flow added f4 41 Liq. 93 - © 2015 NatIonal Fire Pretection Association NFPA 13 Nodal K. Nominal ings L ft (in) total (pt) length Notes ? ft (in) (pet) (bar) elev (Ps) Node 2 - Total flow (Q) Actual 1D Tft (in) fiat (Pt) 3 1 DI 1. 3.. S1 I5P -.DO 02- ___ '36 q•o ___ 3 _____ ____ 2-is £J,5 ___ /O ii•30 __________ i-71- i( /0.3 ' IQ 3°7- /Icc,2 ($-r) 1.0 ., l 0..) 10 2c -I L j 3637 ii , I° ii / _I eop 1 o t1O7 iY?/J 75 i3 87 7 5 0L O/;ifi7c 1' FIGURE 23.3.5.1.2(d) Detailed Workaheet 2016 EdItion Copyright 2016 Nabsnal Are Protection Association (NFPA). Licensed, by agreement forindMdual use and download on August 4,2016 to Dennis Grubb Assoc for designated user Uennis Uneru. no uuler uuon tranemisslort In onyloun pennhtted without written permission of NFPA. For Inquiries or to report unauthorized use, contact Ucenslng@nfpa.org. This NSS All Access subscription expfres on Januanj 11. 2017. 13-262 INSTALLATION OF SPRINKLER SYSTEMS Job new:- Shea IL ccv Sheet number. _28 1)P2. 2- ICIOI9 Rz) ) 16 0 $4c,iX 1-7-16 PIPE INFORMATION Node 1 1 K. Fe Flow this dep a Nominal Fitfiugs— and length L ft Cm)Factortotal (Pt) Notes Mct(Pj fJt (us) (psi) (bar) elev (P8) Node 2 Total flow (Q) Actual ID Tft(m) 150 'I19j ILI / 2.; Olt, 2,1 '' (0 ©2015 National Fire PnAssoclatlon NFPA 13 FIGURE 23.35.1.2(d) Detailed Worksheet. 2016 EditIon - - z r) - - ---- - CD 4 t,O&fzThY4llc tqC101 Fire & Building I/ Pmdticts Technical Servlces Tel: (800)381-93121 Fax: (M)M-5= BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet rapidilesponseu HOME FIRE SPRINKLER SYSTEM General Description TyccrFire &.Bulidlng:Products(rFEP). BlazeMaster CPVC Pipe and Fittings are deslgnedexdus ivety lbr use In wet pipe automatic, fire sprinkler systems.. They aremade.fromaspecia!ty devel- oped thermoplastic compound: com-posed: of post. chlorinated.'polyvinyl chloride (CPVC) resin-and state of the art additives. TFBP1 BlazeMaster CPVC products: are easier to install than traditional steel pipe. systems. andat•the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. AU female pipe thread adapters have brass Inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe. With flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Poe and Fittings described herein must be inst8ffedand maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro-tection Association, In addition to the standards ofanyotherauthoritles hav- ing Jurisdiction. Failure to do so may Impair the performance of these de- The owner Is responsible for maintain-ing their fire protection system and de-vices In proper cperatlng condition. The lnstafling contractor or sprinkler manufacturer should be contacted with any questions. Technical Data- sizes 314 to3 Maximum Working Pressure 175 psi Approvals ilL FM CUL NSF,, Dade County,, LPCS; MEA, and the City oiL M lea. (Refer to 1H4900, Rev. % Janu-ary 2005 Installation: Instruction: &' Technical Handbook' for exact llst- Inglapproval information.) Manufacture Source U.S.A. Material Pipe: ASIM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange fllazeMastøs,s a regkdwedtrwfema* of No veon IP Holding Cc. I POTTER FOR SMALLPIPE VSR-S VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD Stock No. 1144440 Installation must be perfomed by qualified personnel and in accordance with all national and local codes and ordinances. Shock hazard. Disconnect power source before servicing. Serious injury or death could result. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. UL, ULC, CSFM Listed and NYMEAAccepted Service Pressure: Up to 300 PSI (20,7 BAR) Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM) UL Maximum Surge: 18 FPS (5,5 m/s) Enclosure: Die-cast, red enamel finish Cover held in place with tamper resistant screws Contact Ratings: Two sets of SPDT (Form C) 10.0 Amps at 125/250 VAC 2.0 Amps at 30 VDC Resistive 10mAmps mitt, at 24 VDC Conduit Entrances: Two openings provided for 1/2" conduit Individual switch compartments suitable for dissimilar voltages. Usage: Listed plastic, copper and schedule 40 iron pipe. Fits pipe sizes - 1" (25mm), 11/4" (32mm), 1 1/2- (38mm) and 2" (50mm) Note: 12 paddles are furnished with each unit, one for each pipe size of threaded and sweat TEE, one for 1" (25mm) CPVC, one for 1" (25mm) CPVC (Central), one for 1" tbreacledNibco CPVC, and one for 1 1/2" (38mm) threaded (Japan). Environmental Specifications: NEMA-411P54 Rated enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. Temperature range: 400 F to 1200 F, (4,50 C to 490 C) UL Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-1 3D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090148 (See Fig. 7 for terminations) Replaceable Components: Retard/Switch Assembly, stock no. 1029030 The Model VSR-S is a vane type waterfiow switch for use on wet Installation sprinkler systems that use 1" (25mm), 1V4" (32mm), 1½" (38mm) or 2" (50mm) pipe size. The unit may also be used as a sectional waterfiow detector on large systems. The unit contains two single pole double throw snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when afiow of 10 gallons per minute (38 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure Screw the device into the TEE fitting as shown in Fig.2. Care must be The VSR-S switches and retard device are enclosed in a general purpose, taken to properly orient the device for the direction of waterflow die-cast housing. The cover is held in place with two tamper resistant The vane must not rub the inside of the TEE or bind in any way. The screws which require a special key forremovaL Afield installable cover stem should move freely when operated by hand. tamper switch is available as an option which maybe used to indi c a t e T h e d e v i c e c a n also be used in copper or plastic pipe installations with unauthorized removal of the cover. See bulletin number 5401103 for the proper adapters so that the specified TEE fitting may be installed installation instructions of this switch. on the pipe run. Note.' Do not leave cover off for an extended period of time. ' PotterElectric Signal Company, LLC •2081 Craig Road, St. Louis, M0,63146-4161 •Phone: 800-325-3936/Canada 888-882-1833• www.pottersignal.com PItINTEDINUSA MFG.#5401206- REV G PAGE IOF3 I2JO8 These devices may be mounted in horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where theywilibe accessible. The units shoulduot be installed within 6" (15cm) of a valve, drain or fitting which changes the direction of the waterfiow. Select the proper paddle for the pipe size and type of TEE used see Fig. I for instructions on changing paddle. The unit has a 1" NPT bushing for threading into a non-corrosive TEE. See Fig. 2 for proper TEE size, type and installation, Use no more than three wraps of teflon tape. .UP POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as lire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4"(101 nun) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, IJLC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment: Indoor or outdoor use (See Note 1) to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells -4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-340 to 660C). Z Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical 4B at 10 ft (3m) (2) Minimum dB at 10 ft (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA4-12 1750080 .12A 90 77 10(250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC 1%4BA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC P8A248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) I20VAC PBAI206 1806120* .05A 92 83 8(200) I20VAC PBAI208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have IJLC listing. In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 orBBX-1. Standard electrical boxes will not provide a weatherproof enclosure, if the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC St. Louis, MO, Phone: 8 6 6 - 5 7 2 - 3 0 0 5 / C a n a d a 8 8 8 - 8 8 2 - 1 8 3 3 w w w . p o t t e r s i g n a l . c o m ---- -- '-' PRINTED IN USA MPG. #5400776 - REV Y-1 PAGE I 0F2 01/13 Class 125 Bronze Ring Check® Valves Inline lift type • resilient discs • spring actuated 125 PSI/8.6 bar saturated steam to 3530 F/178° C (PTFE Disc) 250 PSII17.2 bar non-shock cold working pressure MATERIAL UST PART SPECIFICATION Body Bronze ASTM 8584 Alloy C84400 Stem Stainless Steel ASTM A 582 Alloy C30300 Spring 316 Stainless Steel Disc Holder Stainless Steel Type 301 Disc Water. Oil or Gas (Buna-N) Steam (PTFE) (Y) Seat Screw Stainless Steel ASTM A276 Alloy S43000 Body End Bronze ASTM B584 Alloy C84400 1-480 Threaded S-480 Solder Dimensions Size A B C In. mm. I. mm, in. mm. In mm. T-480$-410 lbs. m. Lbs. Ku. Master Cm. Oty. % 10 2.00 51 1.38 35 1.44 37 0.41 0.19 0.44 0.20 100 ½ 15 2.06 52 1.38 35 1.19 30 0.36 (116 0.40 0.18 100 V4 20 2.25 57 1.63 41 1.31 33 0.48 0.22 0.52 0.24 100 1 25 2.63 67 2.00 51 1.50 38 0.77 0.35 0.85 0.38 50 11/4 32 2.94 75 2.38 60 1.69 43 1.14 0.51 1.28 0.58 30 1½ 40 3.31 84 2.75 70 2.00 51 1.63 0.74 1.75 0.79 30 2 50 3.69 94 3.38 86 2.31 59 2.27 1.03 2.70 1.23 10 OrdethiW The T.4111 and 3-481 both have standard Buns-N Discs. Also available with PTFE 00 DIscs; specify T481-YorS-488.Y %"thin ? require ½ pound pressure to open. Install pipe diameters minimum downstjeam train pump discharge or changes is direction to avoid fluwtnitulance. Flow straighteners may be required In extreme canes. Note On pump discharge, the preferred check valves aver inline, spring assisted, center-gilded, lift checks. T480-Y (PTFE Disc) NPTxNPT FB NIBCO® Check Valves may be Instilled is both horizontal and vertical lines with upward flower is any Inteim8dinte position. Warning -Do Not Use For Recipurselleg Air Compressor Service. 1480-V (PTFE Disc) C x.0 For detailed Operating Presser. refer to Visit our website for the most current information. Preemie Teinperalure Chides page 114 D NJBCO INC. WORLD HEADQUARTERS • 1516 MIDDLERURY St • WO4ARt IN 465164740 • USA • PH: 1.800.234.0227 TECH SERVICES PH: 1.888.446.4226 • Fc 1.88823&0657 • INTERNATIONAL OFFiCE PH: +1.514295.3327 • FA) +1.514.2953455 ....... tq a Fire Protection Products Worldwide www.tyco-fire corn contacts I RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinklers, Flat Plate Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Se- ries LFII Residential 4.9 K-factor Con-cealed Pendent Sprinklers (TY3596) are decorative, fast response, fus- ible solder sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch 02,7 mm) vertical adjustment This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 130 wet and dry pipe residential sprin- kler systems for residential occu- pancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA .13 IMPORTANT Always refer to. Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal-lation of sprinkler systems and com- ponents. Improper handling and In-stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate ma fire situation or cause It to operate prematurely. Pane I of 6 The Series I.F1I Residential Concealed Pendant Sprinklers (1Y3596) has been designed with heat sensitivity and wa-ter distribution characteristics proven to help in the control of residential fires and to Improve the chance for occu-pants to escape or be evacuated. The Series LFII Residential Concealed Pendent Sprinklers ,(TY3596) are shipped with a Disposable Protective Cap. The Protective Cap is temporar-ily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being In-stalled or finished. The tip of the Pro-tective Cap can also be used to mark the center of the ceiling hole Into plas-ter board, ceiling flies, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling Installation Is complete the Protective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, It has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendant Sprinklers (TY3596) need not be increased over the number of de- sign sprinklers (hydraulic design area) as specified for wet pipe sprinkler sys- tems, as Is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendant Sprinklers of-fer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hy- draulic design area) for systems de- signed to NFPA 13,13D, or 13R. FEBRUARY 2014 Wi'Ie1SII The Series LA! Residential Con-cealed Pendant Sprinklers (1Y3596) described herein must be Installed and maintained in compliance with this document and with the applica-ble standards of the National Fire Pro-tection Association, in addition to the standards of any authorities having ju-risdiction. Failure to do so may impair the performance of these devices. The owner Is responsible for maintain- ing their fire protection system and de-vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number 1Y3596 TFP442 TFP442 Page 4 of 6 WET PIPE SYSTEM Maximum Minimum Flow and Residual Pressure°1 Covera ge Maximum Spacing Ordinary Temp. Rating Area ( Ft. 160°F (71°C) Minimum Ft. x Ft. (m x m) (m) Deflector to Ceiling Installation Type Spacing R. Flow Pressure GPM PSI (m) (L/min) (bat) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per 8 16 x 16 16 13 7.0 (4,9 x 4,9) (4,9) (49,2) (0 NFPA 13D or 13R, or 13. Installed in Concealed,48) (24) 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below 20x20 20 20 16.7 bottom of (6,1 x6,1) (6,1) (75,7) (1,15) beam (a) For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage_,a for which hydraulic design criteria are stated. (b). Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. (c) For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure Ordinary Temp. Rating Minimum Coverage Area'. Maximum Spacing Ft. x Ft. Ft. (m) 160°F (71°C) Deflector to Installation Spacing Flow Pressure (m x m) Ceiling Type Ft. GPM PSI (m) (L/min) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) (0157) Beamed Ceilings per NFPA 13D or Concealed 13R, 8 (2,4) 16x16 (4,9 x 4,9) 16 (4,9) 15 (56,8) 9.4 (0,65) or 13. Installed In 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x6,1) (6,1) (79,5) (1,27) beam For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area of the flow In accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFiI RESIDENTIAL 4.9 K-FACTOR FLAT-PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA tqca Fire Protection Products Worldwide www.tyco-fire.corn Contacts I Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TV- FRB Pendent Sprinkler, where applica- ble, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently dam- age a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. NOTICE The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this doc- ument, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY313 .......Upright 5.6K, 1/2 NPT TY323 ......Pendent 5.6K, 1/2 NPT Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved CE Certified Sprinklers with Polyester Finish are UL and C-UL Listed as Corrosion-Resis- tant Sprinklers. Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* * The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Un- derwriters Laboratories, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/barl/2) Temperature Rating 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Finishes Sprinkler: Refer to Table A Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ...................Bronze Button..............Brass/Copper Sealing Assembly.........Stainless Steel w/TEFLON Bulb ......................Glass Compression Screw........Bronze Deflector.................Bronze