Loading...
HomeMy WebLinkAbout2864 WHIPTAIL LOOP; 100; FPC2017-0045; PermitPERMIT REPORT 4ity of Carlsbad Print Date: 01/25/2022 Job Address: 2864 WHIPTAIL LOOP, # 100, CARLSBAD, CA Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091201000 Track #: Valuation: $70,602.18 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: ELEVATE -SPRINKLER TI <100 HEADS (68) BUILDING B / SUITE 100, 103, 104, 105, 109 ALL SUITES ON ONE PLAN Permit No: FPC2017-0045 Status: Closed - Finaled Applied: 02/16/2017 Issued: 03/10/2017 Finaled Close Out: 02/05/2021 Inspector: Final Inspection: FPContractor: EPIC FIRE PROTECTION INC 765 TURTLE POINT WAY SAN MARCOS, CA 92069-8126 (760) 310-6122 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page _1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov PERMIT FPC2017-0045 2864 WHIPTAIL LOOP #100 SUITES 100,103,104, 105 m 109 ARE ALL ON SAME PLANS QUICK RESPONSE EXTENDED COVERAGE PENDENT QUICK RESPONSE EXTENDED COVERAGE RECESSED PENDENT mono wali ~U~b FIRE SPRINKLER CORPORATION QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS MODEL GL8109 PENDENT • RECESSED PENDENT QUICK RESPONSE EXTENDED COVERAGE LIGHT HAZARD AUTOMATIC SPRINKLERS MODEL GL8109 PENDENT • RECESSED PENDENT SPECIFICATIONS AND APPROVALS DESCRIPTION AND OPERATION The Globe Quick Response Model GL8109 Extended Coverage Pendent Sprinkler for Light Hazard occupancies is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While this Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard light hazard extended coverage pendent sprinklers are specified; but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction, in accordance with their listings and in accor- dance with NFPA 13. The heart 'of Globe's GL Series sprinkler proven actuating as- sembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in waterdischarge which is distributed in an approved pattern. TECHNICAL DATA See reverse side for Approvals and Specifications. Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C) Water Working Pressure Rating - 175 psi (12 Bars) Factory tested hydrostatically to 500 psi (34 Bars) Maximum low temperature glass bulb rating is -67°F (-55°C) Frame - bronze • Deflector - brass • Screw - brass Bulb seat - copper. Spring - nickel alloy• Seal - teflon Bulb - glass with alcohol based solution, 3mm size Escutcheon Assembly - steel flDiJk°I Cc T=MDS:0AT11PJ= RATINa'CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 'cc ORANGE/RED Sffi INTERMEDIATE YELLOW/GREEN NOV 2016 GFS-205 (Formerly A.41) [ SIN NOMINAL I THREAD I LENGTH I FINISHES I cULus I I MODEL "K" FACTOR SIZE I I j Factory Bronze I I GL8109 8.0(llametnc) 3I4NPT )20rrnn 3' (7.6cm) Chrome White Polyester' I x I Black Polyesteru I I NOTE, METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'AVAILABLE AS cULun LISTED AS CORROSION RESISTANT WHEN SPECIFIED ON ORDER. cULus LISTING DESIGN . USE REQUIREMENTS FOR LIGHT HAZARDS ONLY TEMPERATURE MAX. AREA OF I I MIN. DISTANCE I SIN MODEL STYLE COVERAGE LENGTHcWIDTH MIN. PRESSURE I MIN. FLOW I G.P.M. y.m,ij I I I BETWEEN I I SPRINKLERS I 135°F I 555°F ' I 175F I 2001° (SC) I l6Bc) I l79Cl (93c) Foot (MeNlo) P.5.19-am) I I I Feet (MeNlo) I PENDENT X 16(4.9)516(4.9) 10.3(0.71) I 26(98) I I I I I MI. 5)x 18 (5.5) 16.6(1.14) I 33(125) GL8109 RECESSED X X X I 8(2.4) I PENDENT I I I I X - - - 20(6.1) a 20(6.1) 24.4(1.88) I I 40(151) NOTE, METRIC CONVERSIONS ARE APPROXIMATE. SPRINKLERS SHALL BE LIMITEDAS PER THE REQUIREMENTS OF NPPA13 AND PAY OTHER RELATED DOCUMENTS. FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED, USE THE MINIMUM FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH DESIGN CRITERIAARE STATED. CROSS SECTION 3/4" ADJUSTMENT RECESSED PENDENT ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own manufactured Quantity • Model Number • Style • Orifice products found to be defective in material or workmanship for a Thread Size Temperature • Finishes dos/rod period of one year from date of shipment. Quantity - Wrenches - P/N 325390 For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List). Quantity - %' Adjustable Recessed Escutcheons Quantity - Recessed Wrenches - PIN 325391 Quantity - Protective Caps - PIN 327109-CAP (Friction Fit Recessed) 4077 AIRPARI< DRIVE, STANDISH, MICHIGAN 48658 - G BE 989-846-4583 FAX 989-846-9231 1-800-248.0278 WWE.globesprinkler.cem IITKIN NOV 2016 PRINTED U.S.A. GFS-205 (Formerly A.41)