HomeMy WebLinkAbout890 PALOMAR AIRPORT RD; ; FPC2019-0291; PermitPERMIT REPORT
CQ of
Carlsbad
Print Date: 01/25/2022
Job Address: 890 PALOMAR AIRPORT RD, CARLSBAD, CA 92011-4443
Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm
Parcel #: 2110213600 Track #:
Valuation: $379,056.50 Lot #:
Occupancy Group: Project #:
#of Dwelling Units: Plan #:
Bedrooms: Construction Type:
Bathrooms: Orig. Plan Check #:
Plan Check #:
Permit No: FPC2019-0291
Status: Closed - Finaled
Applied: 12/30/2019
Issued: 01/08/2020
Finaled Close Out: 04/01/2020
Inspector:
Final Inspection:
Project Title:
Description: WINDMILL FOOD HALL -REVISION TO PLANS FOR TI EXISTING FA SYSTEM CHANGES AND ADDITIONS (ADDED 2ND FLOOR INT(
SCOPE OF WORK) DELTA 6 REVISIONS
Applicant: FPContractor:
JOHNSON CONTROLS SECURITY SOLUTIONS JOHNSON CONTROLS SECURITY SOLUTIONS
LLC LLC- DO NOT USE
MALCOLM DCOSTA 3870 MURPHY CANYON RD, # 140
3870 MURPHY CANYON RD, # 160 SAN DIEGO, CA 92123-4403
SAN DIEGO, CA 92123-4403 (561) 226-8210
(619) 805-5300
FEE AMOUNT
FIRE Plan Review Per Hour - Office Hours $136.00
FIRE Plan Review Per Hour - Office Hours $204.00
FIRE Reinspection (per inspection) $193.00
FIRE TI Fire Alarm System AddI Inspection $271.00
Total Fees: $804.00 Total Payments To Date: $668.00 Balance Due: $136.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
HIGHLIGHTED SET
Cut Sheets and CSFM Listing Sheetsj For:
Windmill Food Hall
Tenant Improvements
890 Palomar Airport Road
Carlsbad, California 92008
Revision 6 - Changes and Additions
Installer:
Johnson of(,
Controls
tqcn
Integrated Security
3870 MURPHY CANYON ROAD
SUITE 140
SAN DIEGO, CA. 92123
(800) 289-2647
LIC 4977249 (C-b, C-7)
4, SYSTEM
SENSOR
Indoor Selectable-)
Output Strobes and
Horn Strobes for)___
Ceiling Applications
System Sensor L-Series audible visible notification
products are rich with features guaranteed to cut
installation times and maximize profits with lower
current draw and modern aesthetics.
Features
Plug-in design with minimal intrusion into the back box
Tamper-resistant construction
Automatic selection of 12- or 24-volt operation
at 15 and 30 candela
Field-selectable candela settings on ceiling units:
15, 30, 75, 95, 115, 150, and 177
Horn rated at 88+ dBA at 16 volts
Rotary switch for horn tone and two volume selections
Universal mounting plate for ceiling units
Mounting plate shorting spring feature checks wiring continuity
before device installation
Electrically Compatible with legacy SpectrAlert and SpectrAlert
Advance devices
Compatible with MDL3 sync module
Listed for ceiling mounting only
Agency Listings
SIGNAI.ING
0
LISTED APPROVED
S5512 FM approved except 7125-1653:0504
S4011 for ALERT models 7135-16535503
3057383
The System Sensor L-Seies offers the most versatile and
easy-to-use line of horns, strobes, ard horn strobes in the industry
with lower current draws aid modern aesthetics. With white and red
plastic housings, wall arc ceilng mounting options, System Sensor
L-Series can meet virtually an" application requirement.
The entire L-Series prcdjct line of neil ng-mount strobes and horn
strobes include a variet of features that increase their application
versatility while simplifylig ins:alati3r. All devices feature a plug-in
design with minimal intrusion mb :he back box, making installations
fast and foolproof while virtual y eliminating costly and time-
consuming ground faults.
To further simplify installation, the L-:Saries utilizes a universal
mounting plate so instavers can mojnt them to a wide array of back
boxes. With an onboarcl shcrtng sp ng, installers can test wiring
continuity before the device is insta led.
Installers can also easil-, adapt dev:es to a suit a wide range of
application requirements us;ng tielc--selectable candela settings,
automatic selection of 12-o 24-volt operation, and a rotary switch
for horn tones with two --cljme selecotons.
L-Series Specifications
General
L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-
gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used
for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, [-Series
products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output
and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs
shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor
L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.
Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177.
Strobe
The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service. The strobe
shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible
signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and
associated lens/reflector system.
Horn Strobe Combination
The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective
service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act
requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist
of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a
temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe
models shall operate on a coded or non-coded power supply.
Synchronization Module
The module shall be a System Sensor Sync-Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module
shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns
on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also
control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more
synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply.
Standard Operating Temperature 32°F to 120°F (0°C to 49°C)
Humidity Range 10 to 93% non-condensing
Strobe Flash Rate 1 flash per second
Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR1
Operating Voltage Rang& 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal)
Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V (24V nominal)
lnputTerminal Wire Gauge 12 to 18 AWG
Ceiling-Mount Dimensions (including lens) 6.8" diameter x 2.5" high (173 mm diameter x 64 mm high)
Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9" diameter x 3.4" high (175 mm diameter x 86 mm high)
(SBBCRL, SBBCWL)
Notes:
Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs
P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 cd.
AV0566800
(UL Current Draw Data
UL Max. Strobe Current Draw (mA RMS)
8-17.5 Volts
Candela DC
(16-33 Vol
(DC FWR
(15 87 (41 60
30 153 63 86
(75'N/A Ciii) 142
95 N/A 134 164
115 N/A 158 191
150 N/A 189 228
177 N/A 226 264
DC Input
8-17.5 Volts
15cd 30cd
16-33 Volts
15cd 30cd 1,75ccf, 95cd 115cd 150cd 177cd
Temporal High) 103 167 71 90 (143 165 187 217 254
Temporal Low 96 165 54 71 137 161 185 211 249
Non-Temporal High 106 173 71 90 141 165 187 230 273
Non-Temportal Low 95 166 54 71 124 161 170 216 258
3.lKTemporal High 111 164 69 94 147 163 184 229 257
3.lKTemporal Low 103 163 54 88 143 155 185 212 252
3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271
3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259
16-33 Volts
FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd
Temporal High 107 135 179 198 223 254 286
Temporal Low 78 101 151 172 199 229 262
Non-Temporal High 107 135 179 198 223 254 286
Non-Temportal Low 78 101 151 172 199 229 262
3.1K Temporal High 108 135 179 200 225 255 289
3.lKTemporal Low 79 101 150 171 196 229 260
3.1K Non-Temporal High 108 135 179 200 225 255 289
3.1K Non-Temporal Low 79 101 150 171 196 229 260
Horn Strobe Tones and Sound Output Data
Horn and Horn Strobe Output (dBA)
Switch Position Sound Pattern dB
8-17.5
Volts
DC
16-33
Volts
DC FWR
1 Temporal High 84 89 89
2 Temporal Low 75 83 83
3 Non-Temporal High 85 90 90
4 Non-Temporal Low 76 84 84
5 3.1 KHz Temporal High 83 88 88
6 3.1 KHz Temporal Low 76 82 82
7 3.1 KHz Non-Temporal High 84 89 89
8 3.1 KHz Non-Temooral Low 77 83 83
AVDS86830
L-Series Dimensions
2.47
1.37
Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box
Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box
L-Series Ordering Information
)Ceiling Horn Strobes
PC2RL 2-Wire, Horn Strobe, Red
PC2WL 2-Wire, Horn Strobe, White
Model Description
Ceiling Strobes
(SCAL) Strobe, Red)
SCWL Strobe, White
SCWL-CLR-ALERT Strobe, White, ALERT
Accessories
TRC-2 Universal Ceiling Trim Ring Red
TRC-2W Universal Ceiling Trim Ring White
SBBCRL Ceiling Surface Mount Back Box, Red
SBBCWL Ceiling Surface Mount Back Box, White
"S TEM 52017 Systenr Sensor 3825 Ohio Avenue • St. Charles, IL 60174 Product specifications subject to change adhout notice. visit oystemsensor.cam
SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 AVDSO
for current product ntormatroe, ncluthng the latest version at this data sheet.
6801 • 03117
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. c73:5-153:00 Page 1 of 2
CATEGORY: 7135 --AUDIBLE DEVICE
LISTEE: Syslm Sensor,Unincorporated Div of Honeywell Int'l lnc3825 Ohio Ave, St. Charles, IL
60174
Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309
Email: megan.sisson@honeywell.com
DESIGN: System Sensor Indoor 2-wire and *4..wire Models:
HWL, HRL, HGWL and HGRL Horns;
CHWL and CHRL Chimes;
P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *4f\fl
Wall Horn Strobes;
(PC2RL PC2WL, *PC4RL and *pc4wL(ceiling Horn Strob(;s)
CHSRL and CHSWL Wall Chime Strobes;
CHSCRL and CHSCWL Ceiling Chime Strobes;
Wall Bezel Parts:
BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG,
BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG,
BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG,
BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG,
Ceiling Bezel Parts:
BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG,
BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG.
Color Lens:
LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and
LENS-RC2.
WallTrim Rings:
*TR2 and *TR2W
CeilingTrim Rings:
*TRC2 and *TRC2W
Wall Surface Mounted Back Boxes:
SBBRL, SBBGRL, SBBWL and SBBGWL,
Ceiling Surface Mounted Back Boxes:
Revision 08-21-2017 dcc
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2019 p r Listing Expires June 30, 202O
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
Listing No. 7135-1653:0503
Page 2 of 2
SBBCRL and SBBCWL
MP120KL 120 VAC Adapter Mounting Plate
Refer to listee's data sheet for detailed product description and operational considerations.
RATING: 12 VDC regulated and 24 VDC/FWR
INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes &
ordinances and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating, and UL label.
APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control
units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be
consulted prior to installation. Refer to listee's Installation Instruction Manual for details.
Revision 08-21-2017 dcc
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2019 (Listi,ing ExpJIS (June 30, 2020)
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION
OFFICE OF THE STATE FIRE MARSHAL
FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM
LISTING SERVICE
LISTING No. (7125-1653:0504) Page 1 of 2
CATEGORY: (7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIREp)
LISTEE: LSystem Sensor, Unincorporated Div of Honeywell Int'l Inc.825 Ohio Ave, St. Charles, IL
60174
Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309
Email: megan.sissonhoneywell.com
DESIGN: System Sensor Indoor 2-wire Models:
SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT
Wall Strobes;
SCWL and SCWL-CLR-ALERT(çling Strob]
Wall Bezel Parts:
BZR-F, BZR-AL, BZR-AG, BZR-EV, BZR-P, BZR-SP, BZR-PG,
BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG,
BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG,
BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG,
Ceiling Bezel Parts:
BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG,
BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG.
Color Lens:
LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and
LENS-RC2.
WallTrim Rings:
TR2 and TR2W
CeilingTrim Rings:
TRC2 and TRC2W.
Wall Surface Mounted Back Boxes:
SBBRL, SBBGRL, SBBWL and SBBGWL,
Ceiling Surface Mounted Back Boxes:
SBBCRL and SBBCWL
Refer to listee's data sheet for detailed product description and operational considerations.
*Rev 04-04-19 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2019 (istgExpJDs (June 30, 2020]
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division
Listing No. 7125-1653:0504
Page 2 of 2
RATING: Regulated 12 VDC setting: 8-17.5 VDC
Regulated 24 VDC/fwr setting: 16-33 VDC
INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes &
ordinances and in a manner acceptable to the authority having jurisdiction.
MARKING: Listee's name, model number, electrical rating, and UL label.
APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately
listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal
ceiling mounted. *Listed with software code, S05-0048-001 for low temperature
compensation. Authority having jurisdiction should be consulted prior to installation. Refer to
listee's Installation Instruction Manual for details.
*Rev 04-04-19 gt
This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed
the test results and/or other data but does not make an independent verification of any claims. This listing is not
an endorsement or recommendation of the item listed. This listing should not be used to verify correct
operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other
Date Issued: July 01, 2019 (Listing Expires) (June 30, 2O
Authorized By: DAVID CASTILLO, Program Coordinator
Fire Engineering Division