HomeMy WebLinkAbout705 PALOMAR AIRPORT RD; 300; FPC2020-0088; PermitPERMIT REPORT
4ity of
Carlsbad
Print Date: 01/25/2022
Job Address: 705 PALOMAR AIRPORT RD, # 300,
Permit Type: FIRE-Construction Commercial
Parcel #: 2101001600
Valuation: $277,106.58
Occupancy Group:
#of Dwelling Units:
Bedrooms:
Bathrooms:
Project Title:
Description: AEROTEK -SPRINKLER TI (52 HEADS)
CARLSBAD, CA 92011-1060
Work Class: Fire Sprinklers
Track #:
Lot #:
Project #:
Plan #:
Construction Type:
Orig. Plan Check #:
Plan Check #:
Permit No: FPC2020-0088
Status: Closed - Finaled
Applied: 05/14/2020
Issued: 07/07/2020
Finaled Close Out: 08/17/2020
Inspector:
Final Inspection:
Applicant: FPContractor:
TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC
JOHN CAPUTO 1611 S MELROSE PL, # 244
1611A S MELROSE DR VISTA, CA 92081-5471
VISTA, CA 92081-5407 (760) 525-4329
(760) 525-4329
FEE AMOUNT
FIRE NFPA 13 or 13R System 7 - 100 heads $553.00
Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00
4
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov
Upright Pendent
Vertical Sidewall Horizontal Sidewall
Recessed Concealed
Horizontal Sidewall Pendent
ReIiabk f2c..2.O2D - OOBulletin 014 Rev.
Model Fl FR Series
Quick Response
Standard Spray
Model Fl FR56 Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Vertical Sidewall
Horizontal Sidewall LI
Conventional
*
Recessed
Pendent/F1/F2
Recessed
PendentjFP
XLH Recessed
Pendent F1/F2
(4)
XLH Recessed
Pendent FP
Model Fl FR56 Recessed Sprinkler Types
Standard Pendent/F1/F2/FP
Horizontal Sidewall
Model Fl FR56 Concealed Sprinkler Types
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler
Types
Standard Upright
Standard Pendent
Model Fl FR42, Fl FRXLH & Fl FR28 Recessed
Sprinkler Types
Standard Pendent
Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler
Types*
Standard Pendent
Less than 0.25% Lead Content
Listing & Approvals
Underwriters Laboratories Inc. and Certified for
Canada (cULus).
Factory Mutual Approvals (FM)
Loss Prevention Council (LPCB, UK)
VdS SchadenverhUtung GmbH
*NSF Certified to NSF/ANSi Standard 61 Annex G
EC Certificate: 0786-CPD-40239 (RA1414), 0786-
CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1 475)
UL Listing Category
Sprinklers, Automatic & Open (VNlV)
Quick Response Sprinkler
Product Description
Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & F1FR28 Series Sprinklers are quick response
sprinklers which combine the durability of a standard sprin-
kler with the attractive low profile of a decorative sprinkler.
The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH & Fl FR28 Series Recessed automatic sprinklers
utilize a 3.0 mm frangible glass bulb. These sprinklers have
demonstrated response times in laboratory tests which are
five to ten times faster than standard response sprinklers.
This quick response enables the Model F1 FR56, F1FR56LL,
XLH Upright XLH Pendent
F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Series sprinklers to apply wa-
ter to a fire much faster than standard
sprinklers of the same temperature rat-
ing.
The glass bulb consists of an accu-
rately controlled amount of special fluid
hermetically sealed inside a precisely
manufactured glass capsule. This glass bulb is specially
constructed to provide fast thermal response.
At normal temperatures, the glass bulb contains the fluid
in both the liquid and vapor phases. The vapor phase can
be seen as a small bubble. As heat is applied, the liquid
expands, forcing the bubble smaller and smaller as the liq-
uid pressure increases. Continued heating forces the liquid
to push out against the bulb, causing the glass to shatter,
opening the waterway and allowing the deflector to distrib-
ute the discharging water.
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
Application
Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be
exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest
published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick
response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
*Pin tie
(XLH Only)
Deflector
Load Screw
Washer Bulb
Frame Cup
O14FGO6A
Model F1FR42, F1FRXLH Upright
Technical data:
Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish
Pressure Pressure
F1FR56
**F1 FR56LL0 K 5.6
Quick 1/2" NFl See See F1FR42
**F1 FR42LL0} K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature 'Finish Table"
F1FRXLH Ratings" Table.
F1FR28 K2.8
(1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C
Material Data:
Frame Deflector Load Screw *Pintle Cup Washer Bulb
DZR Brass CDA Alloy 260,
CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360
QM Brass or or or coated with PTFE Adhesive Glass
**Low Lead Brass or
CDA Alloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape
Model Fl FR56, Upright, Pendent & Conventional Sprinklers
Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
(SIN)
Size US Metric Height Organization I Upright Pendent
Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position
1/2" (15mm))" 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 3,4, 6 RA14250(2)(3)(4)
7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA1413 4
3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA1411 4
Conventional-Install in Upright or Pendent Position
15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753
cULus listed corrosion resistant (Polyester coated) sprinkler.
Polyester coated FM approved sprinkler.
Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475.
Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant
Upright Pendent Conventional
Model Fl FR56LL & Fl FR42LL Pendent Sprinklers
Installation Wrench: Model D Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number
(SIN)
Size US I
i Metric Height Organization Pendent
Standard-Pendent Deflectors Marked to Indicate Position
1/2" (15mm) (1)
7/16(11mm) 1
1/2" NPT (R1/2)
1
5.6 I 80 2.25" (57mm) 1,5 RA1415
1/2" NPT (R1/2) ] 4.2 60 2.25" (57mm) 1,5 RA1410
cULus listed corrosion resistant (Polyester coated) sprinkler.
*DuPont Registered Trademark
3.
Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414
7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) RA1413
3/8" (10mm) 1 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA141 1
(1) Refer to escutcheon data table for approvals & dimensions
Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1)
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Nominal
Orifice
Thread
Size
K Factor Sprinkler
Height
Sprinkler Identification Number
(SIN) US Metric
1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415
7/16" (10mm) I 1/2" NPT (R1/2) 1 4.2 60 1 2.25" (57mm) RA1410
(1) Refer to escutcheon data table for approvals & dimensions
—
—
,X 7/2RESJEER
NREUMCM7 USD1 55SF AGaJNST SERRUIIR RIVhVN MOSS---.FACE F IW CLIUNG DIMENSION
I At -MW RECESS — 1725-1]
- AIAIUSIMENF :a,AT AT MINIMUM RECESS 3/879.5mm) f1
FE ESCCECERS#
I Al MAXIMUM RECESS - 1/8722.2mm)
(12 Ar MINIMUM RECESS 1-5/8747.3mm) F? XSCUIT.l*lNv
Ar MAXIMUM RECESS ?—I/872&6mm) Al MINIMUM RECESS - 7-5/8747.3mm)
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 Fl or F2
7X 7/2RCEUcER
2 5/8 014. [6M7mmJ HOLE IN CEIUNG
2 5/78 014. [54. 7,nm]
CUP
FACE OF F7777N0
70 FACE OF COILING 9/MOOS/ON
IT MRS/MUM RECESS —
IT MINIMUM REV —
____
AT MAXIMUM RECESS - 9/I67l4.ss,s,J
Y-7'12.7--1 AT MINIMUM RECESS - 1T254mmJ J I
3 1/4 Dt
Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH &
F1FR28 FP
Model Fl FR56 Quick Response Vertical Sidewall Sprinkler
Installation Wrench: Model D Sprinkler Wrench
Installation Position: Upright or Pendent
Approval Type: Light Hazard Occupancy
Installation Data:
Nominal Nominal K Factor Sprinkler Approval Sprinkler
US Metric Orifice Thread Size Height Organizations Identification
Numbers (SIN)
½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3
15mm 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) RA1485 23
111LPC Approval is for pendent position only.
cULus Listed corrosion resistant (Polyester coated) sprinkler.
Electroless Nickel PTFE (Teflon")* Plated - cULus listed Corrosion Resistant
Vertical Sidewall
*DuPont Registered Trademark 4
Sprinkler Type Deflector to Ceiling Distance
(Min. - Max.)
Upright 4(102mm) - 12" (305mm)
Pendent 4(102mm) - 12" (305mm)
Temperature Ratings
Classification
Sprinkler
Temperature Max. Ambient
Temp. Bulb Color
0 OF
Ordinary 57 135 100°F (38°C) Orange
Ordinary 68 155 100°F (38°C) Red
Intermediate 79 175 150°F (66°C) Yellow
Intermediate 93 200 150°F (66°C) Green
High (1) 1 141 1 286 1 225°F (107°C) I Blue
(1) Not available for recessed sprinklers.
Escutcheon Data (1)
(1) SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for light
hazard" onI while FM limits use for same hazard with F2 escutcheon only.
Maintenance
The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL,
F1FRXLH and Model F1FR56, F1FR56LL, F1FR42,
Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should
be inspected and the sprinkler system maintained in accor-
dance with NFPA 25. Do not clean sprinklers with soap and
water, ammonia or any other cleaning fluids. Remove dust
by using a soft brush or gentle vacuuming. Remove any
sprinkler which has been painted (other than factory ap-
plied) or damaged in any way. A stock of spare sprinklers
should be maintained to allow quick replacement of dam-
aged or operated sprinklers. Prior to installation, sprinklers
should be maintained in the original cartons and packaging
to minimize the potential for damage to sprinklers that would
cause improper operation or non-operation.
Sprinkler Types
Standard Upright
Standard Pendent
Conventional
Recessed Pendent
Vertical Sidewall
Horizontal Sidewall
Recessed Horizontal sidewall
Concealed pendent
Maximum Working Pressure
175 psi (12 bar)
100% Factory tested hydrostatically to 500 psi (34.5 bar)
Finishes (1)
Standard Finishes
Sprinkler Escutcheon Cover plate0)
Bronze Brass Chrome
Chrome Plated Chrome White
Polyester Plated
Coated (4)(5)(6) White Painted
Special Application Finishes
Sprinkler Escutcheon Cover plate'
Electroless Nickel
PTFE(Teflon®)"7)
Electroless Nickel
PTFE (Teflon®)* Bright Brass
Bright Brass 3 Bright Brass Black Plating
Black Plated Black Plated Black Paint
Black Paint216 Black Paint Off White
Off White (2)(6) Off White Satin Chrome
Chrome Dull Chrome Dull
Other finishes and colors are available on special order. Consult the
factory for details. Custom color painted sprinklers may not retain their
UL Corrosion resistance listing. Coverplate custom paint is semi-gloss,
unless specified otherwise.
cULus Listed only.
200°F (93°C) maximum.
cULus listed corrosion resistance" applies to SIN Numbers RA1435
(HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and
RA1415 (Pendent) in standard black or white. Corrosion resistance in
other polyester colors is available upon request.
FM Approvals finish as "Polyester coated" applies to SIN Number
RA1414, RA1435 and RA1425 in standard black or white.
LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475.
cULus listed Corrosion Resistant
Ordering Information
Specify:
Sprinkler Model
Sprinkler Type
Orifice Size
Deflector Type
Temperature Rating
Sprinkler Finish
Escutcheon Type
Escutcheon Finish (where applicable)
Cover plate Model
Cover plate Thread size
Cover plate Temperature
Cover plate Adjustment
Cover plate Finish
Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers
and escutcheons are packaged separately.
"DuPont Registered Trademark
7.