HomeMy WebLinkAbout705 PALOMAR AIRPORT RD; 300; FPC2020-0088; PermitPERMIT REPORT 4ity of Carlsbad Print Date: 01/25/2022 Job Address: 705 PALOMAR AIRPORT RD, # 300, Permit Type: FIRE-Construction Commercial Parcel #: 2101001600 Valuation: $277,106.58 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: AEROTEK -SPRINKLER TI (52 HEADS) CARLSBAD, CA 92011-1060 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2020-0088 Status: Closed - Finaled Applied: 05/14/2020 Issued: 07/07/2020 Finaled Close Out: 08/17/2020 Inspector: Final Inspection: Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, # 244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 4 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov Upright Pendent Vertical Sidewall Horizontal Sidewall Recessed Concealed Horizontal Sidewall Pendent ReIiabk f2c..2.O2D - OOBulletin 014 Rev. Model Fl FR Series Quick Response Standard Spray Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall LI Conventional * Recessed Pendent/F1/F2 Recessed PendentjFP XLH Recessed Pendent F1/F2 (4) XLH Recessed Pendent FP Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS SchadenverhUtung GmbH *NSF Certified to NSF/ANSi Standard 61 Annex G EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1 425), 0786-CPD-40252 (RA1 475) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie (XLH Only) Deflector Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL0 K 5.6 Quick 1/2" NFl See See F1FR42 **F1 FR42LL0} K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature 'Finish Table" F1FRXLH Ratings" Table. F1FR28 K2.8 (1) Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US Metric Height Organization I Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2" (15mm))" 1/2" NPT (R1/2) 5.6 I 80 2.25" (57mm) 1, 2, 3,4, 6 RA14250(2)(3)(4) 7/16" (10mm) 1/2" NPT (R1/2) 4.2 60 2.25" (57mm) 1 RA142314 RA1413 4 3/8" (10mm) 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA1411 4 Conventional-Install in Upright or Pendent Position 15mm (1) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 1 RA14753 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon)* Plated - cULus listed Corrosion Resistant Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread Nominal K Factor Sprinkler Approval Sprinkler Identification Number (SIN) Size US I i Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2" (15mm) (1) 7/16(11mm) 1 1/2" NPT (R1/2) 1 5.6 I 80 2.25" (57mm) 1,5 RA1415 1/2" NPT (R1/2) ] 4.2 60 2.25" (57mm) 1,5 RA1410 cULus listed corrosion resistant (Polyester coated) sprinkler. *DuPont Registered Trademark 3. Model Fl FR56, Fl FR42, Fl FRXLH & Fl FR28 Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1414 7/16" (10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) RA1413 3/8" (10mm) 1 1/2" NPT (R1/2) 2.8 40 2.25" (57mm) RA141 1 (1) Refer to escutcheon data table for approvals & dimensions Model Fl FR56LL & Fl FR42LL Quick Response Recessed Pendent Sprinkler(1) Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Sprinkler Identification Number (SIN) US Metric 1/2" (15mm) 1/2" NPT(R½) 5.6 80 2.25" (57mm) RA1415 7/16" (10mm) I 1/2" NPT (R1/2) 1 4.2 60 1 2.25" (57mm) RA1410 (1) Refer to escutcheon data table for approvals & dimensions — — ,X 7/2RESJEER NREUMCM7 USD1 55SF AGaJNST SERRUIIR RIVhVN MOSS---.FACE F IW CLIUNG DIMENSION I At -MW RECESS — 1725-1] - AIAIUSIMENF :a,AT AT MINIMUM RECESS 3/879.5mm) f1 FE ESCCECERS# I Al MAXIMUM RECESS - 1/8722.2mm) (12 Ar MINIMUM RECESS 1-5/8747.3mm) F? XSCUIT.l*lNv Ar MAXIMUM RECESS ?—I/872&6mm) Al MINIMUM RECESS - 7-5/8747.3mm) Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Fl or F2 7X 7/2RCEUcER 2 5/8 014. [6M7mmJ HOLE IN CEIUNG 2 5/78 014. [54. 7,nm] CUP FACE OF F7777N0 70 FACE OF COILING 9/MOOS/ON IT MRS/MUM RECESS — IT MINIMUM REV — ____ AT MAXIMUM RECESS - 9/I67l4.ss,s,J Y-7'12.7--1 AT MINIMUM RECESS - 1T254mmJ J I 3 1/4 Dt Model F1 FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 FP Model Fl FR56 Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Nominal K Factor Sprinkler Approval Sprinkler US Metric Orifice Thread Size Height Organizations Identification Numbers (SIN) ½" (15mm) ½" NPT (R1/2) 5.6 80 2.25" (57mm) 1, 2, 3 15mm 1/2" NPT (R1/2) 5.6 80 2.25" (57mm) 3(1) RA1485 23 111LPC Approval is for pendent position only. cULus Listed corrosion resistant (Polyester coated) sprinkler. Electroless Nickel PTFE (Teflon")* Plated - cULus listed Corrosion Resistant Vertical Sidewall *DuPont Registered Trademark 4 Sprinkler Type Deflector to Ceiling Distance (Min. - Max.) Upright 4(102mm) - 12" (305mm) Pendent 4(102mm) - 12" (305mm) Temperature Ratings Classification Sprinkler Temperature Max. Ambient Temp. Bulb Color 0 OF Ordinary 57 135 100°F (38°C) Orange Ordinary 68 155 100°F (38°C) Red Intermediate 79 175 150°F (66°C) Yellow Intermediate 93 200 150°F (66°C) Green High (1) 1 141 1 286 1 225°F (107°C) I Blue (1) Not available for recessed sprinklers. Escutcheon Data (1) (1) SIN RA1435 - cULus permits use with Fl, F2 or FP escutcheons for light hazard" onI while FM limits use for same hazard with F2 escutcheon only. Maintenance The Model F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH and Model F1FR56, F1FR56LL, F1FR42, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Sprinklers should be inspected and the sprinkler system maintained in accor- dance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory ap- plied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of dam- aged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Maximum Working Pressure 175 psi (12 bar) 100% Factory tested hydrostatically to 500 psi (34.5 bar) Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate0) Bronze Brass Chrome Chrome Plated Chrome White Polyester Plated Coated (4)(5)(6) White Painted Special Application Finishes Sprinkler Escutcheon Cover plate' Electroless Nickel PTFE(Teflon®)"7) Electroless Nickel PTFE (Teflon®)* Bright Brass Bright Brass 3 Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint216 Black Paint Off White Off White (2)(6) Off White Satin Chrome Chrome Dull Chrome Dull Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414 and RA1475. cULus listed Corrosion Resistant Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Cover plate Model Cover plate Thread size Cover plate Temperature Cover plate Adjustment Cover plate Finish Note: When Model Fl FR56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. "DuPont Registered Trademark 7.