Loading...
HomeMy WebLinkAbout362 WALNUT AVE; ; FPR2019-0221; Permit((7city of Carlsbad Print Date: 10/06/2020 Job Address: 362 WALNUT AVE, CARLSBAD, CA 92008-3151 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2041321703 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Multifamily Fire Alarm Permit No: FPR2019-0221 Status: Closed - Finaled Applied: 11/12/2019 Issued: 01/09/2020 Finaled Close Out: 10/06/2020 Inspector: Final Inspection: Project Title: Description: WALNUT BEACH HOMES -SPRINKLER MONITORING FOR 2 BLDGS (14 DEVICES, NEW CONSTRUCTION, 11 UNIT CONDO PROJE 3 STORIES) Applicant: FPContractor: SYMONS FIRE PROTECTION SYMONS FIRE PROTECTION INC ANGELA ZUMAYA 12155 PAINE PL 12155 PAINE PL POWAY, CA 92064-7154 POWAY, CA 92064-7154 (619) 588-6364 (619) 588-6364 FEE AMOUNT FIRE Sprinkler Monitoring $766.00 Total Fees: $766.00 Total Payments To Date: $766.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov ______• ':W AW S. Fire Sprinkler Monitoring System Complete Material Submittal Prepared for: Walnut Beach Homes 362 Walnut Ave Carlsbad, CA 92008 December 3rd, 2019 :Ff K ~,O ~ ~ - 02U- 1 12155 Paine Place • Poway, CA 92064 • (619) 588-6364 • Fax (619) 588-6805 • CA Lic. #682025 I.?i=cDLJ I'C E:I Li L '0 I LIdIL TABLE OF CONTENTS - FIRE ALARM SYSTEM SUBMITTAL 1. FIRE ALARM SILENT KNIGHT - FIRE ALARM CONTROL PANEL - 5104B INTERSTATE - FIRE ALARM BATTERIES 7Ah - 12V - SLA-O 124 SPACE AGE— FIRE ALARM DOCUMENT CABINET - ACE-i 1 TELGUARD - FIRE ALARM CELLULAR DIALER - TG7-FS SILENT KNIGHT - FIRE ALARM PULL STATION - SK-PULL-DA SILENT KNIGHT - FIRE ALARM SMOKE DETECTOR - 2W-B S S 12155 Paine Place G Poway, CA 92064 0 (619) 588-6364 G Fax (619) 588-6805 G CA Lic. #682025 5104B "41 Fire Control Communicator The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-atone unit, it can be used to monitor: Sprinkler systems for waterf low, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line . connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to the central station. If one of the telephone lines faults for more than 60 seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of the six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. FEATURES & BENEFITS UL bb4 Listed as an Six fully supervised I-useless overload Reports in SIA and A single, NFPA 72 Central inputs: one Class A protection with most major programmable output Station or Remote input, and five Class B automatic reset communications is provided for alarm Station protected inputs circuitry and fault formats or dialer failed premise unit Downloadable for indicators - Operates on loop start conditions (cannot be FM approved remote programming eliminates the cause phone lines ahead of used for evacuation of most field calls. , purposes). Can be used as a • 60 hours of standby 1 UUU9 stand-alone or as a power • Dual phone line system. add-on DACT interface Automatic self tests every 24 hours with report sent to central station 5104B Technical Specifications PHYSICAL Dimensions: 12.25"W x 14.5"H x 3.0 D (31.1cm W x 36.8 cm H x 7.6cm D) Weight: 15 tbs. (6.75 kg) Color: Red ENVIRONMENTAL Operating Temperature: 32°F to 120°F (0°C to 49°C) Humidity: 10 to 93% relative humidity (non- condensing) ELECTRICAL: Add-on Applications - UL Listed Input: I20VAC 60Hz 40 watts CURRENT: Standby: 50mA Alarm: 135mA STAND ALONE APPLICATIONS Input: 120VAC 60Hz 40 watts Standby: 12V 7 amp hour rechargeable battery 5230 Remote Annunciator: (three maximum per system) Load: 60mA standby, 120mA alarm INDICATOR LIGHTS (LEDS) Power On: (Green) Trouble Silenced: (Yellow) Until Trouble is Cleared/Flashing: Supervisory Dialer Failure: (Yellow) Telephone Line Fault: (2 Red) Inside Cabinet at Li and L2 Inputs TELEPHONE REQUIREMENTS FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE: 0.OB Type of Jack: RJ31X (2 required) ORDERING INFORMATION 510413: Fire Alarm Communicator. Four-zone digital communication of fire and trouble. ACCESSORIES 5230: Remote Annunciator/Programmer 7181: Fire Zone Converter Module 7860: Telephone Connecting Cord for RJ31X Jack (2 required) 6712: 12 volt, 7AH rechargeable battery COMMUNICATION FORMATS: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK L4/2, Radionics BFSK AGENCY LISTINGS AND APPROVALS UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service FM Approved CSFM Approved MEA For a complete listing of all compliance approvals and certifications, please visit www.silentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Honeywell is a registered trademarks of Honeywell International, Inc This document is not intended to be used for installation purposes. We try to keep our product information up-to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444 For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 Doc 350349 I Rev F 05/08 © 2018 Honeywell International Inc. L CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0114 Page 1 of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Model *5104B Provides automatic, manual and waterfiow service when used as a central station protective premise unit. Intended to monitor various initiating devices and transmit to a central station receiving unit various preprogrammed alarm and trouble signals. Refer to listee's data sheet for detailed product description, electrical rating and operational considerations. *5104B *Six zone control/communicator control unit 5230 Remote annunciator/keypad INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. *Rev. 08-01-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data bUt does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should not be used to listee's data sheet, installation instructions verify correct and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TBgRJST S General Purpose Outrageously 0ependab1i The Power of a Perfect Fit Interstate's SLA battery family powers more than devices. They empower the people who use them-and choose them. SLA0826 4V 4.5 Ah 1.89 2.07 Dimensions 3.70 TH 3.94 Terminal 1 Fl SLA0833 4V 8 3.58 1.97 3.98 3.98 F2 SLA0836 4v 10 Ah 4.02 1.97 3.70 3.94 F2 SLA0855 6V ii Ah 2.01 1.65. 2.01 2.24 Fl SLA0865 6V 1.2 Ah 3.82 0.98 2.05 2.24 Fl SLA0184 6v 2.0Ah 1.69 1.46 2.99 2.99 Fl SLA0902 6V 2.8 Ah 2.60 1.30 3.82 4.06 Fl SLA0885 6V 3.2 Ah 528 1.34 2.36 2.60 Fl SLA0905 6V 4.5 Ah 2.76 1,85 4.02 4.17 Fl SLA0906 6V 5 Ah 2.64 2.64 3.78 3.98 Fl SLA0916 6V 5 2.64 2.64 3.82 4.65 SPR SLA0935 6V 7 Ah 3.86 2.20 4.02 4.02 Fl SLA0925 6V 7 Ah 5.94 1.34 3.70 3.94 Fl SLA0945 6V 9 3.86 2.20 4.65 4.72 Fl SLA0955 6V 10 Ah 5.94 1.97 3.70 3.90 Fl SLA0959 6V 12 Ah 5.94 1.97 3.70 3.90 F2 SLA0961 6V 12 Ah 5.94 1,97 370 3.90 Fl SLA0986 6V 20 Ah 6.18 3.27 4.92 4.92 NB SLA0993 6V 42 Ah 6.38 3.46 6.42 6.69 F2 SLA0994 6V 42 Ah 6.38 3.46 6.42 6.85 NB SLA0988 8V 3.2 Ah 5.28 1.42 2.48 2.72 Fl SLA1000 12V 700 mAh 3.78 0.98 2.44 2.44 Plug SLA1 005 12V 1.3 Ah 3.82 1.69 2.09 2.28 Fl SLA0218 12V 2 Ah 2.76 1.89 3.86 4.09 Fl SLA1020 12V 2Ah 5.91 0.79 3.54 3.54 Fl S S Part # 'SLA1016 Volts 12V Ah Capacity* 2.3 Ah L 7.01 w 1.38 Dimensions H 2.36 TH 2.60 Terminal Fl SLA1015 12V 2.3 Ah 701 1.34 2:36 2.36 Fl SLA1022 12V 29 Ah 3.11 2.20 3.90 4.21 Fl SLA0077 12V 2.9 Ah, 3.11 2.20 3.90 4.13 Fl SLA1 042 12V 3 Ah 5,28 2.64 2,36 2.60 F2 SLA1 035 12V 3.5 Ah 5.28 2.64 2.36 2.60 Fl SLA1041 12V 3.5 Ah 5.28 2.64 2.36 2.60 Fl SLA1055 '12V 5 Ah 3.54 2.76 3.98 4.21 Fl SLA1056 12V 5 Ah 3.54 2.76 3.94 4.21 F2 SLA1075 12V 8.Ah 5.94 2.56 3.70 3.94 Fl SLA1079 12V 8 A 5.94 2.56 3.70 3.94 F2 SLA1080 12V 7.5 Ah 5.94 2.56 3.70 3.90 F2 SLA1097 12V 10 Ah 5.94 2.56 4.37 4.61 F2 SLA1104 12V 12 Ah 5.94 3.86 3.66 3.86 F2 SLA1105 '12V 12 Ah 5.94 3.86 3.66 :3.86 Fl SLA1098 12V 12 Ah 5.94 3.86 3..66 4.09 NB SLA1116 12V 18 Ah 7.13 2.99 6.57 6.57 NB SLA1115 12V 18 Ah 7.13 2.99 6.57 6.57 F2 SLA1146 12V 26 Ah 6.50 6.89 4.88 4.88 NB SLA1150 12V 3O Ah 6.50 '4.88 6.89 6,89 NB SLA1156 12V 35 Ah 7.72 5.12 6.22 6.65 INS SLA1155 12V 35 Al, 7.76 5.16 6.26 7.09 Flag SLA1161 12V 44 Ah 7.76 6.50 6.69 6.69 INS SLA1165 12V 55 Ah 9.02 5.43 8.07 8.90 Flag 5LA1160 12V 55 Ah 9.02 5.43 8.27 9.25 NB - Reversed SLA1180 12V 65 Ah 13,70 6.61 7.01 7.01 INS SLA1175 12V 75 Ah 10.20 6.61 8.35 8.98 Flag SLA1185 12V 100Ah 12.09 6.61 8.19 9.06 Flag SLA1189 12V 100Ah 12.09 6.61 8.19 8.43 INS 02019 Interstate Batteries I ABC-985 IN1ER577ATE. IOAML&ES Outrageously Uependable Fire and Security S The Power of a Perfect Fit Interstate's SLA battery family powers more than devices. They empower the people who use them and choose them. *Nomina l capacity, 20 hours S For more information, contact your local Interstate All Battery Center or call 866.884.4635. 1 S Standard Features: Installed with a 4 gig digital flash drive with USB B connector 2 Key ring hooks to hold system keys Business card holder for key contacts Overall Dimensions are 12" x 13" tall and 2 % deep 16 gauge steel box and cover for security Durable powercoat baked on finish other colors available Standard 34"cat 30 key lock other lock as- semblies available Solid stainless steel piano hinge Permanently screened white ink 1" high "Fire Alarm Documents" Legend sheet for passwords and system information ACE-Il FIRE ALARM DOCUMENTS The FAD is the perfect fit to meet the demanding code requirements today. SAE's number one goal is to manufacture code compliant solutions and this product allows you to do just that. NFPA 72 2007 section 6.2.2.1 states, "A record of installed software and firmware version numbers shall be maintained at the location of the fire alarm control unit." This durable 16 gauge steel enclosure with a solid piano hinge and key lock will keep all of your code required documents in one safe place. With a 4GB USB flash drive it stores your fire alarm software safe and secure eliminating the occurrences of the soft- ware not being on site when technicians arrive to service the system. Along with your fire alarm soft- ware you can store your test & inspection docu- ments, service records, manuals & AS built drawings for the system. Using a standard USB B connector it allows you to plug in with any standard SB printer cable to upload or download information. The FDB is designed to hold critical manuals and documents with a durable steel retainer. It has designated hooks to organize key rings and hold important business cards for easy access and reference. Inside the cover it has a organized note table that allows for documentation for passwords and other critical system information. MOO R!GE(ED Made In U.S.A. Space Age Electronics, Inc. 2009 ED0549 LT1 0559 Rev.D 1/2 Space Age Electronics, Inc. www.lsae.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! 4 SPACE AGE ELECTRONICS, INC. Specifications: 0 The fire alarm documents box (FAD) shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a red powder coat epoxy finish. The cover shall be permanently screened with 1" high lettering "FIRE ALARM DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and the hinge shall be a solid width 12" stainless steel piano hinge. The enclosure will supply 4 mounting holes. Inside the enclosure will accommodate standard 8 1/2 x 11 manuals and loose document records that will be protected within the enclosure. A legend sheet will be permanently attached to the door for system required documentation, key contacts and system information. The FAD will have securely mounted inside a minimum of 4 Gigabyte digital flash memory drive with a standard USB B connector for uploading and downloading information. The drive shall not be accessible without tools to any person whom gains access to the records. The enclosure shall also provide 2 key ring holders with a location to mount standard business type cards for key contact personnel. USB Storage Interface Requires Standard USB-B Connector Property Information Certifications and Appr000Io 16.1 System Installation Contractor: 16,5 Authority Roving juriadioSon: .Vd....Mh,,00uo. ..USa .s m.,,thg Pfl0V Equipment infornmtion Minimum Required Documentation (SIG-FUN) 3EO p. yr. Arc 0110110.M d.I'p.% *0 pp.00 *1p0y111 I E- 6M.00.00..0pIObth.dthO0flpy, *114*Om.0I00*SIr*Il.ppIpp*.11001 tppo.g.01p01000p..Ip. I1101*W.10.P010011 SCppInS*d000d0.,Wp.00p.dWfl.O*p.pprd.pph16*.SP82 1ocpy00a.th.ppas.p.nAapp.'.,.a.p..ra 764.0762 II cpproo..ouo.dpp.p.*...pnvp.a. 12 7.110 (*66.24 137.000 039*0110 I.0g. 110 .Or Snt6o.EtppocIpp td000mteo.d sOrlintj0Oltul .0-486.1723 000.1u.00m L715644 6,0.1 Legend sheet for storing system information including contacts, sign-off, maintenance & test information, and alternate locations of additional records. Ordering Information: Part # Description SSU00685 Fire Alarm Storage Cabinet RED Space Age Electronics, Inc 5SU00686 Custom screening with your Logo 800.486.1723 Toll Free Check out our Infinity line eFAD single gang 2 Gig digital storage 508.485.0966 Local solutions (IAMEFAD) 508.485.4740 Fax This document is subject to change without notice, see doc # ED0479 for legal disclaimer No Excuses, Just Solutions! ED0549 LT10559 Rev.D 2/2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0553:0110 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SPACE AGE ELECTRONICS58 Chockett Road, Sterling, MA 01564 Contact: Robert Scholl (508) 485-0966 Fax (508) 485-4740 Email: bobs@lsae.com DESIGN: Models TC2-32, TCI-18, TCX/A 64, TCX/D 128, ACE/A, AC2, ACE/D, IF-2, IFl, lFX/A and lFX/D enclosures. Models ACE-1 1, ACE-12 and ACE-13, *ACE2424, *ACE 3036, *ACE 2436, *ACE 3048 document cabinets. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm equipment enclosures and document cabinets for use with listee's fire alarm equipment. Refer to listee's Installation Instruction Manual for details. S 02-09-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Raj Kosaraju (678) 264-2012 Fax (678) 264-2062 Email: rkosaraju@telular.com DESIGN: Models TG7LAA02, *TG7IJ\001 *TG7LM01 TG7LA002, *TG7LPF01 TG7LAF02, and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model *TG7IJF01 TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. * Revised 10-03-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division TG-7FS CELLULAR ALARM / LTE-V FOR LTE NETWORKS TELGUARD P/NTG7LVF01 t COMMERCIAL FIRE PRODUCT FEATURES :• Certified for use on Verizon's LTE network for long, sunset-free installation. : Meets UL 864 requirements for sole, primary or backup path communications. Minimizes false alarms by providing dual paths for self-tests. The Telguard TG-7FS LTE-V is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LTE-V transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2013 Edition of NFPA 72, the TG-7FS LTE-V can serve as the sole communications path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-V, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LTE-V can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LTE-V because of the new sixty minute supervision mode. The TG-7FS LIE-V can also be installed as a backup path and upgraded to sole path at a later date. Tel guard Ppytà* Telguard rnakesadocin easy with a secure cerr The ft `d' ' allows ecurity. :eà1e*rs a 'stations Uiid Adyanced Reliability icethe.'ability to utilize UItil&teThilar technologies to ciéasvailability an reduoe TG-7FS LTE-V CELLULAR ALARM COMMUNICATOP\ FOR LTE NETWORKS' TELGUARD Powei s 0. 01. - _JN Jd 6OmA Power, onsuml (Standby). '- LTEV ( 25OmA (TrRmIsiô,) La,dhne Tra fo ns UL listed plu-in. 5' Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for Radio Transceiver . . superior in-building penetration. LTEBands4&13 Antenna: Telguard products are easy to install, economical, and UL Listed. 12 ft of .,. mounting b'rãket. Accessories FCC part 15,27 ,an 6tompliant. - • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. . . • HGDL-0: High gain directional antenna. PhysIcaI.DetalIs . EXDL-0: External antenna. 44 • 'M"A 'dn4 ..• - . Shippingeignt8Ib. Operating Environment.is. . 0° +'50!1 +50°C; 1 0.1 9ijumidit '9 UL Listings Commercial Fire Commercial Burglary Residential 864 Control units & 365 Police Station 985 Household fire accessories for fire connected burglar warning systems alarm systems alarm units and 1023 • Household burglar systems alarm systems 1610 central station burglar alarm units; Line security servcies For the most current product specifications and UL Listings visit www.Telguard.com. SECURITY SIGNALING T jr AArM ELECTRONIC SECURITY verigp NETWORK ASSOCIATION LISTED NFPA® '/Il\ . INTERNATIONAL . CERTlFlED Teiguard, a Division of Telular Corporation • 3225 Cumberland Blvd SE Suite 300 Atlanta, GA 30339 USA 800-229-2326, Option 5 www.Telguard.com Copyright Z12017 Teiular Corporation All Rights Reserved S IoneyweEH RMCIM ISILEN SK-PULL-SA I SK-PULL-DA Intelligent Pull Stations The SK-PULL-SA is a single action pull station requiring only one motion to activate the station. The SK-PULL-DA is a dual action pull station requiring two motions to active the station. The SK-PULL-SA and SK-PULL-DA are for use with Honeywell Silent Knight Series fire control panel(FACP). Extremely easy to operate, the SK-PULL-DA and SK-PULL-SA provide a fast and practical means of manually initiating a fire alarm signal. The FACP recognizes each manual pull station by its specific address saving precious seconds in determining the location of an alarm. INSTALLATION The SK-PULL-SA and SK-PULL-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13(5.40 cm) or double gang or 4" (10.61 cm) square electrical box. You can also use the optional (System Sensor PN BG-TR) trim ring if the station is being semi-flush mounted. "41 SK-PULL-SA SK-PULL-DA FEATURES & BENEFITS Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal . operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets ADA requirement for 5 lbs maximum pull force to active Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3 [131) Shell, door, and handle molded from durable LEXAN Reliable analog communications for trouble-free operation Braille text on station handle Rotary address switches for fast installation Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled UL Listed, including UL 38, Standard of Manually Actuated Signaling System CSFM Listed MEA Listed SK-PULL-SA / SK-PULL-DA Technical Specifications For a complete listing of all compliance approvals and certifications, please visit PHYSICAL ORDERING INFORMATION www.silentknight.com. Dimensions: 5.5" H x 4W x 1.45"D (14 x 10.2 x SK-Putt-SA: Single Action Pull Station 3.7cm) SK-Pull-DA: Dual Action Pull Station Microsoft, Windows, and the Windows Logo are Housing Material: LEXAN polycarbonate resin registered trademarks Bi-Colored LED: ACCESSORIES or trademarks of Blinking Green: Normal BG-TR: Optional trim ring. Microsoft Corporation. Steady Red: Alarm SB-I/O: Surface backbox, indoor/outdoor. Silent Knight, System Switch: Single pole, single throw (SPST) normally * Unless otherwise noted, specifications apply to Sensor' and Honeywell' open (N/0) switch which closes upon activation of SK-Pull-SA and SK-Pull-DA are registered the pull station trademarks of Honeywell COMPATIBILITY International, Inc. ELECTRICAL The SK-PULL-SA AND SK-PULL-DA are This document is not Operating Voltage: 15- 32VDC compatible with the following Honeywell Silent intended to be used for SLC Standby and Alarm Current: 350pA Knight fire alarm control panels: installation purposes. We Wire Gauge: Up to 12AWG (3.1 mm2) 6820: Addressable fire alarm control panel try to keep our product information up-to 6820EV5: Addressable fire alarm control panel date and accurate. We ENVIRONMENTAL with an emergency voice system. cannot cover all specific Operating Temperature: 32°F - 120°F (0°C - 6808: Addressable fire alarm control panel applications or anticipate 49°C) 6700: Addressable fire alarm control panel all requirements. All specifications are subject Humidity: 10°/s - 93% non-condensing 5700: Addressable fire alarm control panel to change without notice. 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel For Technical Support, call 800-446-6444 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system For more information Learn more about Honeywell Silent Knight and other products by visiting www.silentknight.com SHoneywell Silent Knight 12 Clintonville Road EX1cThnt®,ii®E1II1 Northford, CT 06472 Doc 3501351 Rev El 11/17 SILENT 8003280103 © 2017 Honeywell International Inc. 1 KNIGHT CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0559:0161 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: SILENT KNIGHT SECURITYOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Megan Sisson (203) 484-6127 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models SK-PULL-SA and SK-PULL-DA single/dual action fire alarm pull boxes. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XLF: 7150-0028:0199 04-16-09 , 0 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division SYSTEM $ SENSOR Photoelectric Smoke Detectors System Sensor j3 series smoke detectors represent significant advancement in conventional detection. The /3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings LISTED <:> 0 MEA MSFM APPROVED approved approved 0. S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease.The il line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors.To complete the installation, i heads plug into the base with a simple Stop-Drop 'N Lock" action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the protocol. The SENS-RDR, a wireless device, displays the sensitivityof P detectors in terms of percent-per-foot obscuration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire P detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. S S ('463 Smoke Detector Specifications S Smoke detector shall be a System Sensor j3 Series model number .listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 135°F (57.2°C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws.The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box.The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2\NT-B, 4\NT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Electrical Specifications Operating Voltage Nominal: 12/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12 V, 23 mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F (0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F (0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble 2WT-B and 4WT-B only: 41°F (5°C) Sensitivity 2.5%/ft nominal InputTerminals 14to22AWG Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Modes LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information Model Thermal 2W-B No 2-wire 130 mA max. limited by control panel 2W7-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12 V, 23 mA @ 24V 4WT-B Yes 4-wire 20mA@ 12V,23 mA@24V Accessories 2W-MOD2 2-wire loop test/ maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76cm) diameter "STEM 3825 Ohio Avenue St. Charles, IL 60174 Product spedfications wbjea to change vothm notice. Visit systemse—com for 5EItJSOR6 Phone: 800-SENSOR2. Fax: 630-377-6495 c,irrent product information, including the latest —ion of this data sheet. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (630) 762-5362 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models 2W-B, 2Wr-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4W1-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (135°17). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 F_ 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire the test results and/or other data but does not make an independent verification Engineering staff of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. operational requirements or installation criteria. Refer to This listing should listee's data sheet, installation not be used to instructions verify correct and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division