Loading...
HomeMy WebLinkAbout2630 VISTOSA PL; ; FPR2019-0151; PermitPERMIT REPORT Lcity of Carlsbad Print Date: 01/26/2022 Job Address: 2630 VISTOSA PL, CARLSBAD, CA 92009-8143 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2162506300 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Project Title: Description: KENNY RESIDENCE -NEW 13D SYSTEM Permit No: FPR2019-0151 Status: Closed - Finaled Single Family Fire Sprinkl Applied: 08/01/2019 Issued: 08/20/2019 Finaled Close Out: 03/26/2020 Inspector: Final Inspection: Applicant: FPContractor: FROEHLICH FIRE PROTECTION INC FROEHLICH FIRE PROTECTION INC JAMES FROEHLICH 619 STEFFY RD 619 STEFFY RD RAMONA, CA 92065-3531 RAMONA, CA 92065-3531 (619) 484-7053 (619) 484-7053 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov Page 1 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom® Residential Pendent Sprinkler VK468 is a small, thermosensitive, glass- bulb residential sprinkler available in several different finishes and temperature ratings to meet varying design requirements. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corro- sion resistant as indicated in the Approval Chart. The orifice design, with a K-Factor of 4.9 (70.6 metrict), allows efficient use of available water supplies for the hydraulically designed I fire-protection system. The glass bulb operating element and special deflector characteris- tics meet the challenges of residential sprinkler standards. t . LISTINGS AND APPROVALS \( '1' Cu/US UL Listed (C-UL-US-EU): Category VKKW EU .. VdS Approved NYC Approved: MEA 89-92-E, Volume 35 WARNING. Cancer and Reproductive Harm- ZL UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metrict) tMetric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Brass UNS-C23000, Phosphor Bronze UNS-051000, or Brass UNS-C26000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Polytetrafluoroethylene (PTFE) Tape Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Compression Screw: Brass UNS-C36000 For ENT coated sprinklers: Belleville spring - Exposed, Screw and PiIcaD - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Sprinkler: Base Part No. 13637 Order Sprinkler VK468 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the tempera- ture rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 175 °F (79 °C) = D For example, sprinkler VK468 with a Brass finish and a 155 °F (68 °C) temperature rating = Part No. 13637AB. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017) Wrench for recessed sprinklers: Part No. 13577W/B* (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool** Part No. 15915 (available since 2010.) *A 1/2' ratchet is required (not available from Viking). **Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Form No. F_012706 19.02.21 Rev 19.1 Replaces Form No. F_012706 Rev 17.1.P65 (Removed F-i Escutcheon.) Page 2 of 5 \tij IF(JIs1 l:II[.1.iu.LIv FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient ' Classification Temperature Rating' Bulb Color U o or Ceiling Temperature' Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion Resistant Coatings': ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Chart. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with ENT coating. W rench Flats Protective Shield Sprinkler 0 5r 5c Figure 1: Standard Sprinkler Wrench 21475M/B Pro±ec±ive Sprinkler Cap Form No. F_012706 19.02.21 Rev 19.1 Page 3 of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Cha Viking VK468, 49 K-Factor Residential Pendent Sprinkler For systems designed to NFPA 130 or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 130 Sprinkler Base L__NPT Thread Size Nominal K-Factor Maximum Water Overall Length SIN Part Number' Inches mm U.S. metric2 Working Pressure Inches mm 13637 VK468 1/2 15 4.9 70.6 175 psi (12 bar) 2-1/4 58 Ordinary Temp Intermediate Temp Max. Coverage Rating (155 °F168 °C) Rating (175 °F179 °C) Listings and Approvals3 Minimum Area Deflector Installation Spacing Ft.X Ft. Flow4 Pressure4 Flow4 Pressure to Type CUL Ft. (mXm) GPM PSI GPM PSI Ceiling US- VdS NYC6 NSF (m) (Umin) (bar) (L/min) (bar) 5 EU 12X12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) Standard 14X14 13 7.0 13 7.0 (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) surface-mounted escutcheons, or See See See See 16X 16 13 7.0 13 7.0 1-1/8 to recessed with Foot- Foot- Foot- Foot- 8 (4.9 X 4.9) (49.2) (0.48) (49.2) (0.48) 2 inch the Micromatic® E-1, E-2, or 10 notes 7 and 10. notes Model 7 and note note (2.4) 18X18 17 12.0 17 12.0 E-3 Recessed (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) Escutcheon 20X20 20 16.7 20 16.7 (6.1 X 6.1) (75.7) (1.15) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. 6 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 35. Approved Finishes are: Brass, Chrome, White Polyester, and Black Polyester9 8 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Approved finish is Electroless Nickel PTFE (ENT). ENT is C-UL-US-EU Listed as corrosion resistant. ENT is available with standard surface-mounted escutcheons or the Micromatic Model E-1 Recessed Escutcheon. Form No. F_012706 19.02.21 Rev 19.1 Sprinkler Wrench 3577\.//B** Must be used for Installing recessed Sprinkler Step 1: Carefully slide the wrench sideways around the deflector and protective shield (Note the orientation of the shield in the wrench,) **A 1/2" ratchet is required (not available from Viking). Page of 5 The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com ELM im Step 2: Corefuily press the wrench upward and turn slightly to ensure ¶ engagement with the sprinkler wrench flots, Figure 2: Wrench 13577W/B for Recessed Sprinkler 1/2" (15 mm) NPT 2-1/4" 1-1/2" II 1111(58 mm) (38,1 mm) (28.7 mm) Sprinkler VK468 Instal led with o standard 1/8" (3.1 mm) surface-mounted escutcheon I 1-3/4" (44,5 mm) Figure 3: Sprinkler VK468 Dimensions with a Standard Escutcheon Form No. F_012706 19.02.21 Rev 19.1 Page 5 of 5 ''I IIlI1GI l.l:IIE•'Yw FREEDOM@ RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Ceiling Opening Size 2-5/16" (58.7 mm) minimum 2-1/2" (63.5 mm) maximum 1-1/8" (28,6 mm) Minimum 1-3/4" 1-1/8" (28,6 mm) Minimum Maximum Installed with a Micromatic Maclet E-1 Recessed Escutcheon (50,8 mm) JME Maximum InstalLed with a threaded Micromatic ModeL E-2 Recessed Escutcheon Figure 4: Sprinkler VK468 Dimensions with the Model E-1 and E-2 Recessed Escutcheons DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The mini- mum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA 13D and NFPA13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614, F_080415 and F_080190 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, VdS, and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Form No. F_012706 19.02.21 Rev 19.1 Replaces Form No. F_012706 Rev 17.1.P65 (Removed F-i Escutcheon.) Page 1 o 5 1IIIr1G® - FREEDOM® RESIDENTIAL II[s1iUI7'iVA CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW Eu Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. WARNING: Cancer and Reproductive Harm- Zt TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 OF (-55 "C) Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Deflector Pins: Stainless Steel UNS-530200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-ClI000 and SS UNS-530400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-543000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-530400 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 OF (68 °C) = B, 200 OF (93 "C) = E For example, sprinkler VK494 with a Brass finish and a 200 OF (93 "C) temperature rating = Part No. 20759AE. Standard Cover Plates: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16") Stainless Steel Cover Plates (not availble with any finish or paint): Base Part No. 21876 (2-3/4" diameter) or Base Part No. 21875 (3-5/16" diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) Page 2 of 5 'tJ II(JIt1G® - FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C =A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Part No. 14047W/B** (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a %" ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler ' Sprinkler Maximum Temperature Rating Cover I Large l Square ' Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Color B lb U Classification Temperature Ceiling Assembly Base Part Base Part Base Part - Rating' Temperature' (Required)3 Number4 Number' Number' Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Red Intermediate 200 °F (93 °C) 150 °F (65 °C) 135 °F (57 °C) 13504 or 13642 or 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes6: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings5: ENT Footnotes I. The sprinkler temperature rating is stamped on the deflector. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Maximum ambient temperature for cover assembly is 100 °F (38 °C). Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Stainless Steel versions are not available with any finishes or paint. Form No.F 012116 18.10.11 Rev 18.1.1365 Page 3 of 5 FREEDOM® RESIDENTIAL 'i II(IF1G ® CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 49 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13,13R or 13D Sprinkler Base SIN NPT Thread Size Nominal K-Factor Maximum Water Wor- Inches mm U.S. metric 2 Part Number king Pressure 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max Coverage 6 Flow GPM Pressure Listings and Minimum Area WXL (LPM) PSI (bar) Deflector to Installation Approvals'-' Spacing Ft. XFt. Ceiling Type Ft. m 155°F(68°C) 200°F(93°C)Temperature c..Lus (m X m) RatedSprinklers EU 12X12 13 7.0 (3.7X3.7) (49.2) (0.48) 14X14 13 7.0 (4.3X4.3) (49.2) (0.48) Concealed with Cover See Footnotes 79 10 8 . X ., W A IU I s) 1.0 (4.9 X 4.9) (49.2) (0.48) Refer to Figure 2 Assembly. See Footnote 8. & 11 (2.4) 18 X 18 17 12.0 (5.5X5.5) (64.4) (0.83) 20X20 20 16.7 (6.1X6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. Meets New York City requirements, effective July 1, 2008. For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. Cover Temperature Rating is 135 °F (57 "C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). a. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 9. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 1. 10.C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) -Stainless Steel Cover plate temperature rating is 135 "F (57 "C). Stainless Steel Cover Part Numbers: 21876' and 21875' (large diameter). Form No. F_012116 18.10.11 Rev 18.1.P65 Page 4 of 5 T FREEDOM® RESIDENTIAL I It II'N. l:II[.cu.7M CONCEALED PENDENT V SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area' in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly Protective cap removed Use wrench 14047 W/B** 2-1/4" (57 mm) diameter opening required in the ceiling. Sprinkler Wrench Part No. 14047 WIB** Step 1: Step 2: t Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or I4031**. A leak tight seal should be achieved by turning the sprinkler clockwise Ito 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Form No. F_012116 18.10.11 Rev 18.1.P65 Page 5 of 5 FREEDOM® RESIDENTIAL I1lII[ii1f.. CONCEALED PENDENT SPRINKLER VK494 (K49) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 2-3/4" (70 mm) or 3-5/16" (84 mm) NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation 1/2"(15 mm) NPT 2-9/16 Ma: -1/16" (52 mm) Minimum I I I 3-5/16" (84 mm) Figure 4: Square Cover Assembly 15394 \\ 'JIKIN I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers Form No. F_012116 18.10.11 Rev 18.1.P65 Replaces Form No. F_012116 Rev 18.1 (Added P65 Warning.) dkydraulic Overview Job Number: 19-02 Renort Descrintion: Residp.ntisl- 2 HD-PROOF Job Job Number Design Engineer 19-02 Job Name: Kenny Residence Phone FAX Address 1 2630 Vistosa Place State Cedi000tion/Llcenso Number Address 2 Carlsbad, CA. AHJ Address 3 Job Site/Building System Density Area olApplication 0.05gpmlft2 900112 (Actual 80112) Most Demanding Sprinkler Data lose Streams 4.9 K-Factor 13.00 at 7.039 5.00 Coverage Per Sprinkler 256112 Number Of Sprinklers Calculated surrrberotSprlrkkro Coleuloted 2 0 byRon, Pr050uroDerrard So,tem Flaw Demand 60.171 26.48 Total Demand 31.48 @60.171 Pressure Result +37.823(38.6%) Supplies Check Point Gauges Node Name Flow(cipm) Hose Flow(ppm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(pm) 1 Water Supply 500.00 5.00 98.000 97.000 BOR 43.282 4.03 26.48 Kenny SPK Water Supply at Node 1 (500.00, 5.00, 98.000, 97.000) 10 rStatic°ressure98006 & 648@60.171 60- CL 31.48 with hose streams 50- 40- System demand curve i ..1 30- - - 111111 'lflllllllltlllllt 20 - - - 10- - - 0- 'i'ii•i."i.i•u.tu.u..u-u-'.w •jjjjj..w ..aj.jj..0 iiiiiiiii _______ 800 900 .: fbP0300 400 500 600 700 1000 Water flOWr gpm ,©M.E.P.CAD, Inc. JAutoSPRlNK2019v15.1.9.0 7/19/2019 7:39:40PM Page 1 111 Hydraulic Summary I Job Number: 19-02 Rnrtrt flpesrnntinn Rcesiolcentjol- 9 H11-PP()Or Job Job Number 19-02 Design Engineer Job Name: Kenny Residence Stole CertitvattonlUoonse Number Address 1 2630 Vistosa Place AHJ Address 2 Carlsbad, CA. Job S,lelBuilding Address 3 Drewing Name Kenny SPK System Remote Area(s) Most Demanding Sprinkler Dote 4.9 K-Factor 13.00 at 7.039 Occupancy Residential- 2 HD-PROOF Job Suffix Home Allowance At Source 5.00 Pressure 0.05gpm/ft2 Area otApplivation 900ft2 (Actual 80ft2) Additional How Supplies Node Flow(gpm) Number 01 Sprinklers Calculated Number At 2 0 N000lex Calculated Coverage Per Sprinkler 2561t2 AutoPeak Results: Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 5.00 System flow Demand 26.48 Total Abler Requited (Including Hose All000anse( 31.48 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Above Ground 14.16 between nodes 9 and 7 Maximum Velocity Under Ground 10.93 between nodes 1 and 2 Volume capacity 0! Wet Pipes 64.36ga1 Volume capacity of Sty Pipes Supplies Node Name Hose Flow (gpm) Static (psi) Residual Flow Available (psi) (gpm) (psi) Total Demand (gpm) Required (psi) Safety Margin (psi) 1 Water Supply 5.00 98.000 97.000 I 500.00 97.994 31.48 60.171 37.823 Contractor Controdor Number Context Name Contact Title Name of Contrawor: Phone Extension Address I FAX Address E.meil Address 3 Web.Site , © M.E.P.CAD, Inc. AutoSPRINK 2019 v15.1 .9.0 7/19/2019 7:39:42PM Page 2 1111Hydraulic Graph Job Number: 19-02 Water Supply at Node I 100— Static Pressure 98.000 I - 500.00 @ 97.000 ------------ 90- 80— 70— 60- 26.48 )60.171 31.48 with hose streams CD a- 50— (I) (0 a) 0 40— = S stem demand curve 30- 20— OH 0_LJ1LI.I.1hIhIh1111111111 111111111 111111111 111111111 111111111 III 111111 200 400 600 800 1000 ioo 300 500 700 900 Water flow, gpm Hydreufls Graph Water Supply at Node 1 Static : Pressure 98.000 Residual: Pressure 97.000 @ 500.00 Available Pressure at time 05 Test 97.994 @ 31.48 System N- 60.171 @26.48 System Derrard lirciudira Floss A0000rca Sr Soureal 60.171 @31.48 , 0 M.E.P.CAD, inc. AutoSPRINK 2019 v15.1 .9.0 7/19/2019 7:39:43PM Page 3 111 1Hydraulic Graph Job Number: 19-02 BOR 100— Static Pressure 98.000 - I @97.000 90T 80— 70— 60— 0) - a- 50- Cn EL 6.48 43.282 31.48 with hose streams 40- 30--- 3 stem demand curve 20— 0 — 1111W LLLU.LL1 '111111 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I ioo 200 300 400 500 600 700 800 900 1000 Water flow, gpm lydroollo Groph BOR Static Pressure N/A Residual: Pressure N/A Available Pressure St Tlrrre of Test N/A Systornssrrarsi 43.282 @ 26.48 Syotcrrr Dcrrrend (lnutudIrre Hose Aeowaneo at Source) 43.282 @ N/A f, © M.E.P.CAD, Inc. J AutoSPRINK 2019 v15.1 .9.0 7/19/2019 7:39:43PM Page 4 1111 Hydrau11c Analysis Job Number: 19-02 Reoort Descriotion: Residential- 2 HD-PROOF Pipe Ty Diameter Flow Velocity HWC Friction Loss ILength Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary =. ..... Route l ..... DR 0.8740 13.00 6.95 150 0.094407 441/2 Pf 0.885 101 7 11-0 11-6 13.00 4.9 7.039 7.707 Sprinkler, E(4-0), Tr(1'-0) 5-0 Pe Pv -0.217 FM 0.8740 26.48 14.16 150 0.352101 2-6 Pt 1.935 7 9 11-6 11-6 13.48 7.707 9.643 Flow (q) from Route 2 T(3-0) 3-0 5-6 Pe Pv FM 0.8740 11.77 6.30 150 0.078599 242-3V2 Pf 23.838 9 5 11-6 10-6 9.643 33.914 T(3-0) 19Tr(1-0), 4E(7-0), 2cp1g(1-0), 31(3-0) 61-0 30331/2 Pe Pv 0.434 FM 1.1010 26.48 8.92 150 0.114373 20-1% Pf 4.816 5 4 10-6 0-0 14.71 33.914 43.282 Flow (q) from Route 3 2E(7-0), f(-0.000), 2Tr(1-0), CV (5-0), EE(1-0), BOR, Z 22-0 4211/2 Pe Pv 4.552 UG 1.0250 26.48 10.30 150 0.162033 5-0 Pf 1.029 4 3 0-0 -1-8 43.282 45.039 EE(1-4) 1-4 6-4 Pe Pv 0.728 UG 1.1010 26.48 8.92 150 0.114373 85-0 Pt 13.722 3 2 4-8 4-8 45.039 58.760 WMV(-4.000) 85-0 Pe Pv UG 0.9950 26.48 10.93 150 0.187254 181/2 Pf 1.410 2 1 4-8 -1-8 58.760 60.171 S, T(5'- 10) 5-10 T61/2 Pe Pv -0.000 5.00 Hose Allowance At Source 1 31.48 =. ..... Route 2 ..... DR 0.8740 13.48 7.21 150 0.100984 0-6 Pt 0.353 102 7 11-0 11-6 13.48 4.9 7.570 7.707 Sprinkler, T(3-0) 3-0 Pe 3-6 Pv -0.217 .Route 3 ..... FM 0.8740 14.71 7.87 150 0.118627 120-11% Pt 23.838 9 5 11-6 10'6 11.77 9.643 33.914 Flow (q) from Route 1 7E(7-0), 6T(3-0), 12Tr(1'-0), cplg(1-0) 80-0 200'11% Pe Pv 0.434 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule 40 Steel Pipe Inside Diameter 4.87 ) = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 f, © M.E.P.CAD, Inc. in AutoSPRINK 2019 v15.1.9.0 7/19/2019 7:39:45PM Page 6 ~ffijHydraufic Analysis I Job Number: 19-02 iepon Description: I<esiaentiai- 2 HD-t-°ttuul- pype Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON DR Drain Drop Discharge gpm BalV Ball Valve DY Dynamic Velocity fps BFP Backfiow Preventer BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN SP Riser Nipple Sprig Pt Total pressure at a point in a Pipe DeIV Deluge Valve ST Stand Pipe Pn Normal pressure at a point in a pipe DPV E Dry Pipe Valve 90° Elbow UG Underground Pf Pressure loss due to friction between points EE 45° Elbow Pe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 221/2* Elbow Pv Velocity pressure at a point in a pipe f Flow Device - fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirE Wirsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. till AutoSPRlNK 2019 v1 5.l.9.0 7/19/2019 7:39:45PM Page 7 1111 Hydraulic Analysis Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary 66 .Route I ..... DR 0.8740 13.00 6.95 150 0.094407 441/2 P1 0.885 101 7 11-0 116 13.00 4.9 7.039 7.707 Sprinkler, E(4-0), Tr(1'-O) 5-0 9 -4/2 Pe Pv -0.217 FM 0.8740 26.48 14.16 150 0.352101 2-6 P1 1.935 7 9 11-6 11-6 13.48 7.707 9.643 Flow (q) from Route 2 . T(3'-0) 3-0 5-6 Pe Pv FM 0.8740 11.77 6.30 150 0.078599 242-31/2 P1 23.838 9 5 11-6 101 6 9.643 33.914 T(3-0) 19Tr(1-0), 4E(7'-0), 2cp1g(1-0), 31(3-0) 61-0 3033h, Pe Pv 0.434 FM 1.1010 26.48 8.92 150 0.114373 2011/2 P1 4.816 5 4 10-6 00 14.71 33.914 43.282 Flow (q) from Route 3 2E(7-0), f(-0.000), 2Tr(1'-O), CV (5-0), EE(1-0), BOR, Z 22-0 421% Pe Pv 4.552 UG 1.0250 26.48 10.30 150 0.162033 5-0 Pt 1.029 4 3 0-0 -1-8 43.282 45.039 EE(1-4) 1-4 6-4 Pe Pv 0.728 UG 1.1010 26.48 8.92 150 0.114373 85-0 Pf 13.722 3 2 -1-8 -1-8 45.039 58.760 WMV(-4.000) 85-0 Pe Pv UG 0.9950 26.48 10.93 150 0.187254 1-81/2 Pf 1.410 2 1 -1-8 4-8 58.760 60.171 5, T(5-10) 5-10 7-61/2 Pe Pv -0.000 5.00 Hose Allowance At Source 1 31.48 .Route2 ..... DR 0.8740 13.48 7.21 150 0.100984 0-6 Pf 0.353 102 7 11-0 11-6 13.48 4.9 7.570 7.707 Sprinkler, T(3'-O) 3-0 3-6 Pe Pv -0.217 =. ..... Route 3 ..... FM 0.8740 14.71 7.87 150 0.118627 120-11% Pt 23.838 9 5 11-6 10'6 11.77 9.643 33.914 Flow (q) from Route 1 7E(7'-0), 6T(3-0), 12Tr(1-0), cplg(1-0) 80-0 200'11% Pe Pv 0.434 lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule 40 Steel Pipe Inside Diameter 4.87 Value ) = Factor C Value Multiplier Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 , © M.E.P.CAD, Inc. 111 AutoSPRINK 2019 v15. 1.9.0 7/19/2019 7:39:45PM Page 6 Job Number: 19-02 fl'rinfi,n Pdn*iL ) flDD11 ~ffijl-lydraulic Analysis Job Number: 19-02 ieporr uescripiion: i<esiaentiai- z hU-F'RUUi- Pp]ype Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON DR Drain Drop Discharge gpm BalV Ball Valve DY Dynamic Velocity fps BFP BV Backfiow, Preventer Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN SP Riser Nipple Sprig Pt Total pressure at a point in a pipe DelV Deluge Valve ST Stand Pipe Pn Normal pressure at a point in a pipe DPV E Dry Pipe Valve 90° Elbow UG Underground Pf Pressure loss due to friction between points EE 45° Elbow Pe Pressure due to elevation difference between indicated Eel 11%° Elbow points Ee2 221/20 Elbow Pv Velocity pressure at a point in a pipe f Flow Device Id Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wrsbo WMV Water Meter Valve Z Cap 1&©MEPCAD, Inc. till AutoSPRlNK2019vl5.1.9.0 7/19/2019 7:39:45PM Page 7 Hydraulic Overview Job Number: 19-02 Rnnrt Dsnrintiryn RsirtpntiaI- 2 I-1r)-(AI C Job Job Number Design Engineer 19-02 Job Name: Kenny Residence Phone FAX Address 1 2630 Vistosa Place State Certification/License Number Address 2 Carlsbad, CA. AHJ Add.. 3 Job Site/Building System Density Area ofApptoetlan 0.05gpm/ft2 900ft2 (Actual 221ft2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 13.00 at 7.039 5.00 Coverage Per Sprtnlder Number Of Sprinklens Calculated ftdvnbe,orcysinktarsCalculated 256ft2 2 0 System P,nan.u,e Demand System Flee Demand 61.849 26.86 Total Demand 31.86 @61.849 Prescure Result +36.145 (36.9%) Supplies Check Point Gauges Node Name Flow(qpm) Hose Flow(ppm) Static(psil Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(ppm) 1 Water Supply 500.00 5.00 98.000 97.000 BOR 44.635 4.02 26.86 Kenny SPK Water Supply at Node 1 (500.00, 5.00, 98.000, 97.000) 100- LI_I I Static Pressure 98.006 90- 80- _ 70- _ 686 @61.849 60 - 31.86 with hose streams 40- System demand curve '1 1 30- 11111 'lflllllllfllllltl 20 10- '.l_I.J..LJ.J.J_? iii ii' till 11111 1lJ.11.I 0 Liii huJJJJ. il.l.l.1.uJ i.l.l.l.l_l.l.I 800 400 600 1000 500 700 900 Water flow, gpm , © M.E.P.CAD, Inc. Ifl Auto SPRINK 2019 v15.1.9.0 7/19/2019 7:39:15PM Page 1 1111 Hydrau1ic Summary Job Number: 19-02 Rnnrt fln'rintiren Pccrok1centiceI 9 I-1rJAI ( Job Job Number 19-02 Design Engineer Job Nome: Kenny Residence State CartiScotionlLlcorse Number Add.. I 2630 Vistosa Place AHJ Address 2 Carlsbad, CA. Job Sirelgulldlrg Address 3 Drawing Name Kenny SPK System Remote Area(s) Most Demanding Sprinkler Data 4.9 K-Factor 13.00 at 7.039 Occupancy Residential- 2 HD-CALC Job Suttlo Rose Allowance At Source 5.00 Pressure 0.05gpm/ft2 Area clAppdcation 900ft2 (Actual 221fi2) Additional Hose Supptoo Node Flow(øm) Number Of Sprinklers Calculated Number Of Nozzles Calculated 2 0 Coverage Per Sprinkler 256ft2 AutoPeak Remits: Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 5.00 System Flaw Demand 26.86 Total Water Required (Including Race Allowance) 31.86 Maximum Pressure Unbalance In Loops 0.000 Maximum Velocity Abase Ground 14.37 between nodes 8 and 6 Meelrrrum Velocity Under Ground 11.08 between nodes 1 and 2 Volume capacity or Wet Pipes 64.36ga1 Volume capacity of Dry Pipes Supplies Node Name Hose Flow Static (gpm) (psi) Residual Flow Available (psi) (gpm) (psi) @ Total Demand Required (gpm) (psi) Safety Margin (psi) 1 \fterSupply 5.00 98.000 97.000 500.00 97.994 31.86 61.849 36.145 Contractor Contractor Number Contact Name Contact role Rome of Cortracton Phone Eetonelcr Address t FAX Address 2 Enroll Address 3 Atab.Site , © M.E.P.CADr Inc. Ifi AutoSPRINK 2019 v15.1.9.0 7/19/2019 7:39:17PM Page 2 IHydraulic Graph Job Number: 19-02 I SsupJUiLL'cac.1ipLiiJii. flVOiUCi Liar £ I iL.rSJtLi.. Water Supply at Node I 100 - Static Pressure 98.000 I 500.00 @ 97.000 90- 80--- 70 6.86 61 .849 60-: -31.86 with hose (C) - streams CL 50 (C) - (C) - a, 40- S stem demand curve 30- 20— 0— WIfflWJJJ.LLuhIIIHH 11111111 IIIIIIII 111111111 IIIIIIP liii III liii II ioo 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hydraulic Graph Water Supply at Node 1 Static: Pressure 98.000 Residual : Pressure 97.000 @ 500.00 Available Pressure at Time or Test 97.994 @31.86 System Derrerrd 61.849 @26.86 System Parr ard Ira kJdirg Hose AlAs. rae at Sou roe) 61.849 @31.86 , © M.E.P.CAD, Inc. R11 AutoSPRINK 2019 v15.1 .9.0 7/19/2019 7:39:18PM Page 3 1111 Hydrau1ic Graph Job Number: 19-02 ' U 1"I ('Al (' BOR 100— Static Pressure _______ 5000 @ 97.000 90 80— 70— 60— (I) - 50— 6.86 44.635 31.86 with hose streams 40- 30 I stern demand curve 20— 200 400 600 800 1000 ioo 300 500 700 900 Water flow, gpm HydrIic Greph BOR Static : Pressure N/A Residual: Pressure N/A Available Pressure at Itme of Test N/A System era 44.635 @26.86 Sy,tarnOeriand(IrrctudirgHreeArowencoetSource) 44.635 @ N/A ,©M.E.P.CAD, Inc. AutoSPRINK2019v15.1.9.0 7/19/2019 7:39:18PM Page INode Analysis Job Number: 19-02 P,,-f ' ur ('Al (' Node Elevation(Foot) Fittings Pressure(psi) Discharge( gpm) 1 4-8 S, T(5-10) 61.849 26.86 201 10-0 Spr(-7.039) 7.039 13.00 202 10-0 Spr(-8.003) 8.003 13.86 2 4-8 WMV(-4.000) 60.401 3 -1-8 EE(1-4) 46.419 4 0-0 EE(1-0), BOR, Z 44.635 5 10-6 T(3'-0) 35.138 6 10-6 T(3'-O), Tr(1'-O) 8.159 , © M.E.P.CAD, Inc. III AutoSPRINK 2019 v15.1.9. 0 7/19/2019 7:39:1 9PM Page 5 Job Number: 19-02 rcepo Friction Loss Fittings 0.094407 Sprinkler, E(4'-O), Tr(1'-O) 0. 36 15 13 Flow (q) from Route 2 T(3-0) 0.094005 16Tr(1-0), 2E(7'-0), 2cp1g(1-0), 3T(3'-O) 0.117430 Flow (q) from Route 3 2E(7'-0), f(-0.000), 2Tr(1'-O), CV (5-0), EE(1'-0), BOR. Z 0.192259 5, T(5'-l0) Hose Allowance uescrlptlon: rcesraenhlal- Z II U*J\LU Length Pressure Eq. Length Summary Total Length 9-2 5-0 14-2 Pt 1.337 Pe -0.217 Pv 2-0% 3-0 5'-0'/2 Pt 1.826 Pe Pv 226-7 41-0 267-7 Pt 25.154 Pe Pv 20'-1'/2 22-0 42-1% Pt 4.945 Pe 4.552 Pv 5-0 14 6-4 Pt 1.056 Pe 0.728 Pv 85-0 85'-0 Pt 13.982 Pe Pv - 1-8% 5-10 7-6% Pt 1.448 Pe -0.000 Pv Pn 0.106317 Sprinkler, Flow (q) from Route 1 9E(7'-0), 14Tr(1'-O), 7T(3'-0), cplg(1'-O) Value Multiplier Value Of C 100 Multiplying Factor 0.713 0-6 Pf 0.372 3-0 Pe -0.217 3-6 Pv 136-8 Pt 25.154 99-0 Pe 235-8 Pv 130 140 150 ~~jj jHydraulic Analysis -Pipe Type Diameter Flow Velocity HI Downstream Upstream Elevation Discharge K-Factor Pt =. ..... Route l ..... DR 0.8740 13.00 6.95 15 201 6 10-0 10-6 13.00 4.9 7.1 8; FM 0.8740 26.86 14.37 15 6 8 10-6 10-6 13.86 8; 9.1 FM 0.8740 12.97 6.94 15 8 5 10-6 10-6 9.1 35 FM 1.1010 26.86 9.05 15 5 4 10-6 0-0 13.89 35 44 UG 1.0250 26.86 10.44 15 4 3 0-0 -1-8 44 46 UG 1.1010 26.86 9.05 15 3 2 -1-8 -1-8 46 60 UG 0.9950 26.86 11.08 15 2 1 -1-8 -1-8 60 61 5.00 1 31.86 Route ..... DR 0.8740 13.86 7.41 15 202 6 10-0 13.86 10-6 4.9 8.003 8.159 =. ..... Route 3 ..... FM 0.8740 13.89 7.43 150 8 5 10-6 12.97 10-6 9.984 35.138 Equivalent Pipe Lengths of Valves and Fittings (C=120 only) ( Actual Inside Diameter Schedule 40 Steel Pipe Inside Diameter 4.87 ) = Factor D39 159 159 84 .0 84 .138 0 .138 .635 0 .635 .419 0 .419 .401 0 .401 .849 f, © M.E.P.CAD, Inc. AutoSPRINK 2019 v15. 1.9.0 7/19/2019 7:39:20PM Page 6 111 IHydrau1ic Analysis Job Number: 19-02 rceport uescriptlon: rcesiaentlal- z Pipype Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge g gpm BalV Ball Valve DR Drop BFP Backfiow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 90° FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN SF Riser Nipple Sprig Pt . . Total pressure at a point in a pipe DelV Deluge Valve ST Stand Pipe Pn Normal pressure at a point in a pipe DPV E Dry Pipe Valve 90° Elbow UG Underground Pf Pressure loss due to friction between points EE 45° Elbow Fe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device -. fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union \NrF Wrsbo WMV Water Meter Valve Z Cap © M.E.P.CAD, Inc. E.nAutoSPRINK 2019 05.1.9.0 7/19/2019 7:39:20PM Page 7 Hydraulic Overview Job Number: 19-02 Rnrert flaerrintiron Rreir1ntre1 I I.Ifl Job Job Number Design Engineer 19-02 Job Name: Kenny Residence Phone FAX Address 1 2630 Vistosa Place Stole CertOoatiorlLioena Number Address 2 Carlsbad, CA. AHI Address 3 Job Sitelguitdirg System Density Ares otApplicotion 0.logpm/ft2 9001t2 (Actual 2441t2) Most Demanding Sprinkler Data Hose Streams 4.9 K-Factor 20.00 at 16.660 5.00 Coverage Per Sprrtder Number Of Spttnldors Calculated NvmberorSptklarsColcruotod 400ft2 1 0 Sysrorn Pressure Demand 505tsrr Flare Demond 52.091 20.00 Total Demand 25.00 @ 52.091 Pressure Result +45.905(46.8%) Supplies Check Point Gauges Node Name Flow(ppm) Hose Ftow(ppm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 1 Water Supply 500.00 5.00 98.000 97.000 BOR 40.128 3.16 20.00 Kenny SPK Water Supply at Node 1 (500.00, 5.00, 98.000, 97.000) 100- Static Pressure 8.O0U a 90 80 7 7n 60 20.00 Q 52.091 ' 25.00 with hose streams U) 40 30 - System demand urve 11111 92 lot, 800 400 600 fl 0Q300 500 700 1000 900 : Water flow, gpm ,,©M.E.P.CAD, Inc. Ifl AutoSPRlNK2019v15.1.9.0 7/19/2019 7:40:03PM Page 1 ~jjjjHydraulic Summary Job Number: 19-02 Rwnnnrt flcem,njntipnn PsecidonfiwL I I-Irk Job Job Number 19-02 Design Engineer Job Hostel Kenny Residence State CadificutiorciUcanna Number Address 1 2630 Vistosa Place AHJ Address 2 Carlsbad, CA. Job SiteiBuiidirg Address 3 Growing Name Kenny SPK System Remote Area(s) Most Demanding Sprinkler Data 4.9 K-Factor 20.00 at 16.660 Occupancy Residential- 1 HD Job Suffix Hose Allowance At Source 5.00 Pressure 0.l0gpm/ft2 Area ctApplication 9001t2 (Actual 244ft2) Additional Hose Supplies Node Flow(gpm) Number Of Sprinklers Calculated Number 01 Noadlas Calculated 1 0 Coceraga Per Sprinkler 400ft2 AutaPeak Rao&dts; Pressure For Remote Area(s) Adjacent To Most Remote Area Total Hose Streams 5.00 System Flow Demand 20.00 Total VrNtar Required (Including Hose Allowance) 25.00 Maximum Pressure Unbalance In Loops 0.000 Maximum tHlctetyAboca Ground 10.70 between nodes 10 and 301 Maximum Velocity Under Ground 8.25 between nodes 1 and 2 Volume capacity of Wet Pipes 64.36ga1 Volume capacity of Dry Pipes Supplies Node Hose Flow 'Name (gpm) Static (psi) Residual Flow (psi) (gpm) Available (psi) Total Demand Required (gpm) (psi) Safety Margin (psi) 1 Water Supply 5.00 98.000 97.000 500.00 97.996 25.00 52.091 45.905 Contractor Contractor Number Contact Name Contact Tdte Name of Contredor: Phone Extension Ad dress t FAX Address 2 E-mail Address 3 WOc.hitO © M.E.P.CAD, Inc. J AutoSPRINK 2019 v15. 1.9.0 7/19/2019 7:40:05PM Page 2 1111 HydrauIic Graph Job Number: 19-02 D.-..-.,..* fl-........-;..*;..... O......:A.....;,.I 4 tin Water Supply at Node I 100— Static 77 Pressure 98.000 500.00 @ 97.000 90 80- 70— 60--- .00 52.091 Z i501: 25.00 with hose streams 40 30 -: S stem demand curve 20- 0_wJJJu.u.Lu.1111111111111111111111111111 111111111 IIIIIIII liii III 111111111 ioo 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hydraulic Graph Water Supply at Node 1 Static : Pressure 98.000 Residual: Pressure 97.000 @ 500.00 Available Pressure at Time sUrest 97.996 @25.00 Systoe,Der,ard 52.091 @ 20.00 Sy em Demer,d Orokidirra Itse uflemerce Ct Geurra) 52.091 @25.00 (, © M.E.P.CAD, Inc. J AutoSPRINK 2019 v15.1.9.0 7/19/2019 7:40:06PM Page 3 1111 HydrauIic Graph Job Number: 19-02 O,...;.-1.......;...I a airs BOR 100— Static Pressure 98.000 I - oo.00 97.000 80--- 7 60--- - Z CL 50— CL 0.00 4O.128 40— 25.00 with hose streams 30- -3 stem demand curve 20- 0_U1111LLU1U1hhhhhhhhh1111111111 111111111 111111111 11111111 11111111 II 111111 200 400 600 800 1000 ioo 300 500 700 900 Water flow, gpm Hydraulic Graph BOR Static: Pressure N/A Reddunl: Pressure N/A Available Pressure at Time of Test N/A System Denrerd 40.128 @ 20.00 Syeterr Derrerd irciudiro hoeeAflosorce erSourcol 40.128 @ N/A , © M.E.P.CAD, Inc. AutoSPRINK 2019 v15.1 .9.0 7/19/2019 7:40:06PM Page 4 111 Hydraulic Analysis -Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary 66 ..... Route l ..... DR 0.8740 20.00 10.70 150 0.209466 2101/2 Pt 2.910 301 10 101-0 10-6 20.00 4.9 16.660 19.353 Sprinkler, E(4'-O), E(7'-0) 11-0 13101/2 Pe Pv -0.217 FM 0.8740 11.88 6.35 150 0.079939 142-1% Pf 13.358 10 5 10-6 10'6 19.353 32.711 Tr(1-0) 11Tr(1-0), 2T(3-0), E(7-0) 25-0 167-11/2 Pe Pv FM 1.1010 20.00 6.74 150 0.068041 20-1% Pf 2.865 5 4 10-6 01 0 8.12 32.711 40.128 Flow (q) from Route 2 2E(T-0), f(-0.000), 2Tr(1-0), cv (5-0), EE(1-0), BOR, Z 22-0 42-1% Pe Pv 4.552 U 1.0250 20.00 7.78 150 0.096394 5-0 Pf 0.612 4 3 0-0 -1-8 40.128 41.469 EE(1'-4) 1-4 6-4 Pe Pv 0.728 U 1.1010 20.00 6.74 150 0.068041 85-0 Pt 9.783 3 2 -1-8 -1-8 41.469 51.252 WMV(-4.000) 85-0 Pe Pv U 0.9950 20.00 8.25 150 0.111398 181/z Pf 0.839 2 4-8 4-8 51.252 52.091 S. T(5'-l0) 5.-10 7-6% Pe Pv -0.000 5.00 Hose Allowance At Source 25.00 =. ..... Route 2 ..... FM 0.8740 8.12 4.34 150 0.039508 221-1% Pf 13.358 10 5 10-6 10'6 19.353 32.711 T(3'-0) 3cp1g(l'-O), 20Tr(1'-0), 10E(7'-0), 7T(3'-0) 117-0 338'l% Pe Pv Equivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule 40 Steel Pipe Inside Diameter 487 ) = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 , © M.E.P.CAD, Inc. 9 AutoSPRINK 2019 v15.1.9.0 7/19/2019 7:40:08PM Page 6 Job Number: 19-02 Rnnrt flp.srintirn RpsidntiI- 1 i-ir 1111Hydraulic Analysis Job Number: 19-02 - eport uescription: i(esiaentiaI- 1 HI) Pipjype Diameter Flow Velocity HWC Friction Loss ILenqth lPressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN DR Drain Drop Discharge gpm BalV Ball Valve DY Dynamic Velocity fps BFP Backflow Preventer BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 900 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN SP Riser Nipple Sprig Pt S Total pressure at a point in a pipe DelV Deluge Valve ST Stand Pipe Pn Normal pressure at a point in a pipe DPV Dry Pipe Valve UG Underground Pf Pressure loss due to friction between points E EE 90° Elbow 45° Elbow Pe Pressure due to elevation difference between indicated Eel 111/40 Elbow points Ee2 221/2* Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WrF Wrsbo WMV Water Meter Valve Z Cap , © M.ESP.CAD, Inc. Ifl AutoSPRINK 2019 v15.l .9.0 7/19/2019 7:40:08PM Page 7 IHydrau1ic_Analysis Job Number: 19-02 Report Description: Residential- 1 HD Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary GO ..... Route l ..... DR 0.8740 20.00 10.70 150 0.209466 210h/z Pt 2.910 301 10 10-0 10-6 20.00 4.9 16.660 19.353 Sprinkler, E(4'-O), E(7'-0) 11-0 13-10% Pe Pv -0.217 FM 0.8740 11.88 6.35 150 0.079939 142-11/2 Pt 13.358 10 5 10-6 10'6 19.353 32.711 Tr(1'-O) 11Tr(1'-0), 2T(3'-0), E(7'-0) 25-0 167'1'/2 Pe Pv FM 1.1010 20.00 6.74 150 0.068041 2011/z Pt 2.865 5 4 10-6 01 0 8.12 32.711 40.128 Flow (q) from Route 2 2E(7'-O), f(-0.000), 2Tr(1'-O), CV (5-0), EE(1'-O), BOR, Z 22-0 42'l% Pe Pv 4.552 UG 1.0250 20.00 7.78 150 0.096394 5-0 Pt 0.612 4 3 0-0 -1-8 40.128 41.469 EE(1'-4) 1-4 6-4 Pe Pv 0.728 UG 1.1010 20.00 6.74 150 0.068041 85-0 Pt 9.783 3 2 -1-8 -1-8 41 .469 51.252 WMV(-4.000) 85-0 Pe Pv UG 0.9950 20.00 8.25 150 0.111398 181/2 Pt 0.839 2 I -1-8 4-8 51.252 52.091 5, T(5'-1 0) 5-10 7-6% Pe Pv -0.000 5.00 Hose Allowance At Source 1 25.00 =. ..... Route 2 ..... FM 0.8740 8.12 4.34 150 0.039508 22111/2 Pf 13.358 10 5 10-6 10-6 19.353 32.711 T(3'-O) 3cplg(1'-O), 20Tr(1'-0), 10E(7'-0), 7T(3'-0) 117-0 33811/2 Pe Pv lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) Actual Inside Diameter ( Schedule Steel Pipe Inside Diameter 487 ) = Factor C Value Multiplier Value Of C 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 (, © M.E.P.CAD, Inc. PjjAutoSPRINK 2019 v15. 1.9.0 7/19/2019 7:40:08PM Page 6 ~jjljHydraufic Analysis Job Number: 19-02 eport uescription: <esiaential- 1 FlU Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Summary Upstream Total Length Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing ON Drain Discharge gpm BalV Ball Valve DR Drop BFP Backflow Preventer DY Dynamic Velocity fps BV Butterfly Valve FM Feed Main Pressure psi C Cross Flow Turn 900 FR Feed Riser Length Foot cplg Coupling MS Miscellaneous Friction Loss psi/Foot Cr Cross Run OR Outrigger HWC Hazen-Williams Constant CV Check Valve RN Riser Nipple Pt i Total pressure at a point n a pipe DelV Deluge Valve SF Sprig DPV Dry Pipe Valve ST Stand Pipe Pn Normal pressure at a point in a pipe E 900 Elbow UG Underground Pf Pressure loss due to friction between points EE 450 Elbow Fe Pressure due to elevation difference between indicated Eel 11W Elbow points Ee2 22W Elbow Pv Velocity pressure at a point in a pipe f Flow Device fd Flex Drop FDC Fire Department Connection fE 900 FireLock(TM) Elbow fEE 450 FireLock(TM) Elbow fig Flange FN Floating Node fT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve SFx Seismic Flex Spr Sprinkler St Strainer T Tee Flow Turn 900 Tr Tee Run U Union WirF Wrsbo WMV Water Meter Valve Z Cap , © M.E.P.CAD, Inc. 11 AutoSPRlNK 2019 v15.1.9.0 7/19/2019 7:40:08PM Page 7