HomeMy WebLinkAbout2310 CAMINO VIDA ROBLE; ; FA100002; PermitCity of Carlsbad Fire Alarm Permit Permit No: FAI 00002 2310 CAMINO VIDA Job Address: ROBLE Permit Type: FALARM Parcel No: 2130500800 Lot #: 0 Status: ISSUED Applied 1/21/2010 Approved: 1/21/2010 Reference No.: Issued: 1/21/2010 PC #: Inspector: Project Title: NORTH COAST CHURCH T.I. FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: JJJ ENTERPRISES R J VIDA ROBLE INVESTORS L L C 533 S VINEWOOD ST 2333 STATE ST #200 ESCONDIDO CA CARLSBAD CA 760-747-3050 Fees ($) Add'l Fees ($) Total ($) Balance ($) 230 0 230 0 L&!EIPRISES FIRE ALARM - SECURITY - LOW vol;FAGE SYSTEMS NORTH COAST CHURCH 2310 CAMINO VIDA ROBLE CARLSBAD, CA FIRE ALARM SYSTEM : FA0 (XX' DN-7101:A Al-110 (Pi) NOTIFIER® with Built-In Communciator by Honeywell General FireWarden-1 00-2(E) IntelIiaent Addressable FACP The Notifier FireWarden-100-2 (NFW2-100) is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This com- pact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Con- sult the wire table on page 3 for specific installation instruc- tions.) The FireWarden- 100-2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. Available accessories include LED, graphic and LCD annunci- ators, and reverse polarity/city box transmitter. The panel is programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. NOTE: Unless otherwise specified, the terms Fire Warden-100-2 is used in this document to refer to both the Fire Warden- 100-2 and the Fire Warden-100-2E FACPs (Fire Alarm Control Panels). Features Listed to UL standard 864, 9th edition, On-board DACT. Four Style V (Class B) or two Class A (Style Z) NAC cir- cuits. Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Up to 32 annunciators or remote annunciators via EIA- 485. ElA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1.000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive, Automatic device type-code verification. One person audible or silent walk test with walk-test tog and printout. Point trouble identification. Waterilow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only detectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 5, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn). See wire table on page 3. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (NC-100). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and auxiliary power outputs is 3.6 amps. (System power increases to 6.6 amps with optional XRM-24 transformer.) PROGRAMMING AND SOFTWARE: Autoprograrn (learn mode) reduces instalation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs.. 99 software zones. Continuous fire protection during online programming at the front panel. DN-7101:A • G9121107 - Page 1 of 4 I Program Check automatically catches common errors not linked to any zone or input point. User interface LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCEIPRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) KEYPAD CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILl SYSTEM RESET (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys ENTER Ordering Options NFW2-100(E): 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. NFW2-100R: Same as NFW2-100, exept in a red backbox. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. DP-9692B: Optional dress panel for FireWarden-100-2. TR-CE-B: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH, Cl-IG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG-120 or CHG-75 required for batteries larger than iSAH. BAT Series: Batteries, see data sheet DN-6933. XRM-24(E): Optional transformer. Increases system power to 6.6 amps. Use XRM-24E with FireWarden-100-2E. PRTIPK-CABLE: Cable printer/personal computer interface cable. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. COMPATIBLE ANNUNCIATORS ACM-BR: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden-100-2, see the following data sheets (docu- ment numbers) ACM-8R (DN-3558), ACS/ACM Series (DN-0524), LDM Series (DN-0551), FDU-80 (DN-6820). COMPA TIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detector. NP-100T: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. ND-100: Photoelectric low-flow duct smoke detector. ND-100R: Photoelectric low-flow duct smoke detector with relay option. NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0" (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NJMM-100P. NZM-100-6Six-zone interface module. Mount one or two modules in a BB-2F cabinet (optional). Mount up to six mod- ules on a CHS-6 chassis in a BB-6F. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-100-2, see the following data sheets (document numbers): NIOO-lSO (DN-6994), NP-IOU/NP-lOOT (DN-6995), NI-100 (DN-6996), NH-100/NH-100R (DN-6997), ND- 100/ND- IOOR (DN-7006), NMM- 100/NMM-iOOP/NDM-100/NZM- 100 (DN-6999), NC-100/NC-100R (DN-7000), NOT-BGI2LX (DN- 7001), and NZM-100-6 (DN-60 150). Page 2 of 4— ON-11O1:A 09/21/07 Wiring Requirements While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical interference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. SLC Wire Requirements Distance in Feet (m) Wire Size Wire Type Non-Plenum (FPLR): Twisted-pair, unshielded 10,000 feet (3,048 m) 12 AWG (3.31 mm2) Genesis 4315, Belden 5020UL Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL FireWarden-100-2 Wire Requirements DN-7101:A .09/21107 - Page 3 014 SYSTEM SPECIFICATIONS System Capacity Intelligent Signalling Line Circuits..........,........ 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring 1 (TR-CE-B): 22.00" (55.88 cm.) high x 19.65" (49.91 cm.) wide. Addressable device capacity ..........................................198 Programmable software zones .........................................99 Annunciators....................................................................32 Electrical Specifications AC Power: FireWarden-100-2: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7 - 18 AH. FireWarden-100-2 cabinet holds maxi- mum of two 18 Al-I batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style Y (Class B) or one Style Z (Class A) for a total of four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 47K ohm, 1/2 watt (PIN 71252 UL listed) for Style V (Class B) NAC. Refer to panel documen- tation and Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.5 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.5 amps for powering four- wire smoke detectors. Power-limited. Refer to Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control, Supervised and power-limited. Telephone Interface: Requires dedicated business tele- phone number with a minimum of 7 volts DC. Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. Cabinet Specifications Door: 19.26' (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x Shipping Specifications Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C160 - 80°F. NFPA Standards The FireWarden-100-2 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterfiow) (requires 4XTM). - REMOTE STATION (Automatic, Manual and Waterfiow) (Where a DACT is not accepted, the alarm, trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual and Waterfiow). - CENTRAL STATION (Automatic, Manual and Waterfiow, and Sprinkler Supervised). - AUTO DETECTOR SELF TEST Agency Listings and Approvals The listings and approvals below apply to the basic FireWar- den-100-2 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7165-0028:235 MEA: 120-06-E, Volume 2 Firewarden® and Notifier® are registered trademarks of Honeywell International Inc. Microsoft® and Windows® are registered trademarks of the Microsoft Corporation. 02007 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so ooi This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate, We cannot cover all specific applications or anticipate all requirements. NtINURINC 11 MANUFA110R1NC All specifications are subject to change without notice. QUALITY SYSTEMS Made inthe U.S. A. For more information. contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com - -*.---------,.-1_ Page 4 of 4— DN-7101:A .09/21/07 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE VFIRV LISTING No. 7165-0028:235 Page 1 of 1 CATEGORY: Control Unit (Commercial)* LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Vladimir.Kireyev@honeywell.com DESIGN: Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). This panel also can be used with NFV-25/50ZST (Fire Voice-25/-50ZST) Zoned System Voice with Telephone for Emergency Voice evacuation Applications. Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL Standard 864, 9th Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:208; 7170-0075:219 *Rev. 08-17-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 17, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6820:A1 • D-123 FDU-80 80 Character Liquid Crystal Display The FDU-80 is a compact, cost-effective, 80 character, backlit LCD Fire Annunciator for use with the NOTIFIER FireWarden- 100-2, NFS-640, NFS2-640, and NFS-320 Fire Alarm Control Panels (FACPs). The FDU-80 mimics the display of the control panel and displays complete system point status information. Up to 32 FDU-80s may be connected onto the EIA-485 Terminal Mode port of each control panel. The FDU-80 requires no programming, which saves time during system commissioning. Features 80-character Liquid Crystal Display. Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. System status LEDs for Power, Alarm, Trouble, Supervi- sory, and Alarm Silenced, No programming necessary— FDU-80 connects to the ter- minal mode port. Displays device type identifiers, individual point alarm, trou- ble or supervisory, zone and custom alpha labels. Time and date display field. Aesthetically pleasing design. May be powered by 24 VDC from the host FACP or by remote power supplies (requires 24 VDC). Up to 32 FDU-80 annunciators per FACP. Plug-in terminal blocks for ease of installation and service. Can be remotely located up to 6,000 feet (1828.8 m) from host control panel. Local piezo sounder with alarm and trouble resound. Semi-flush-mounts to 2.188"/5.556 cm (minimum) deep, three-gang electrical box (NOTIFIER P/N 10103) or three- gangable electrical switchbox. Surface-mounts to NOTIFIER SBB-3 surface backbox. Operation The FDU-80 annunciator provides the FACP with point annun- ciation with full display text on an 80-character LCD display. The FDU-80 also provides an array of LEDs to indicate sys- tem status, and also includes control switches for remote con- trol of critical system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188"/5.556 cm (minimum) deep, three-gang electrical box or three-gangable electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. ( na NOTIFIER 8 by Honeywell -4tANN== AL.. ANNUNCIAr -T.. ! 68201du8.pg Agency Listings And Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635 ULC Listed: CS100 MEA Listed: 245-00-E CSFM: 7120-0028:209 FM Approved Ordering Information FDU-80: 80 character, backlit, LCD Fire Annunciator with con- trol switches for remote control of system functions, and key- switch lock. 10103: Three-gang electrical box, minimum 2.188(5.556cm) deep, for semi-flush-mount applications. SBB-3: Three-gang surface backbox for surface-mount appli- cations. dn-6820:A1 • 02/24/09 - Page 1 of 2 ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ......:... I SO 9001 This document is not intended to be used for installation purposes. _____________ We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENG111MIN9 & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161 FAX: (203) 484-7118. www.notifier.com Page 2 of 2— dn-6820:A1 • 02/24/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION MARKING: APPROVAL: 7120-0028:209 Page 1 of 1 Annunciators Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484-1200 FAX (203) 484-7309 Models FDU-80 and *FDU 80G remote fire annunciators. Units are compact 80-character, backlit LCD fire annunciators. Refer to listee's data sheet for additional detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. Listee's name, product number, electrical rating and UL label. Listed as annunciators for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. *Rev. 10-03-06 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-6995:al • Al -320 NOTIFIER® by_Honeywall GENERAL NP-100, NP-100T Addressable Photoelectric Detectors for the FireWarden Series The NP-100 and NP-100T addressable, low-profile plug-in photoelectric detectors use a state-of-the-art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWar- den Series (FireWarden-100-2 and FireWarden-50) Address- able Fire Alarm Control Panels (FACP5). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annun- ciator capability is available as an optional accessory (P/N RA400Z). FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade entry of address: 01 - 99 with FireWarden- 100-2, and 01 —50 with Fire Warden-50. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED blinks" when the unit is addressed (communi- cating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0" (10.16 cm) octagonal box, or 4.0' (10.16 cm) square electrical box (using a plaster ring - included). Other system features: Fully coated circuit boards and superior RF/transient pro- tection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (P/N RA400Z). NP-100 with B35OLP base NP-100T with B35OLP base APPLICATIONS Use photoelectric detectors in life-safety applications to pro- vide a broad range of fire-sensing capability, especially where smoldering fires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are designed to commercial standards and offer an attractive appearance. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0" (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class B) wiring. dn-6995:al • 05/08/09 - Page 1 of 2 OPERATION Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100-2 and one of 50 possible addresses on the FireWarden-50 Signaling Line Circuit (SLC). It responds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique uni- polar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) without sending an alarm level signal. Because of its unipolar chamber, the NP-100(T) is approximately two times more responsive than most photo- electric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 10 on Inspection, Testing and Maintenance) when installed/connected to a FireWarden-100-2 or FireWar- den-50 addressable tire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- Warden-50 for record keeping. SPECIFICATIONS Voltage range: 15 - 32 VDC (peak). Standby cur en 300 p 0 14 VDC. LED current 6.5 mA 24VC (latched "ON"). Air velocity: 4,000 ft. mm. (20 rn/sec.) maximum. Diameter: 6.1" (15.5 cm) installed in B71OLP base. Height: 2.1" (5.33 cm) installed in B71OLP base. Weight: 3.6 oz. (102 g). Operating temperature range: for NP-100: 0°C to 49°C (32°F to 120°F); for NP-100T. 0°C to 38°C (32°F to 100°F). Temperature: 0°C - 49°C (32°F - 120°F). Relative humidity: 10% - 93%, non-condensing. LISTINGS Listings and approvals below apply to the NP-100 and NP- 100T detectors. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed, file SillS. CSFM approved: file 7270-0028:231. MEA approved: file 243-02-E Vol. II, Maryland State Fire Marshal: permit 2173. FM approved. PRODUCT LINE INFORMATION NP-100: Adressable photoelectric detector; B71OLP base included. NP-lOOT: Same as NP-100 but with thermal element; B71OLP base included. B71OLP: Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB: Plug-in System Sensor relay detector base. Diame- ter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8,89 cm) octagonal box. All mounting boxes have a mini- mum depth of 1.5" (3.81 cm). B224Bl: Plug-in System Sensor isolator detector base. Maxi- mum 25 devices between isolator bases (see DN-6994). Diameter: 6,2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501 BH-2: Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). B501BHT-2: Plug-in System Sensor temporal tone sounder detector base. ACCESSORIES: RA400Z: Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with 8501 and B71OLP bases only. SMK400E: Surface mounting kit provides for entry of surface wiring conduit. For use with 8501 base only. RMK400: Recessed mounting kit. For use with 8501 base only. M02-04-00:Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. 155-127-01 0: Detector removal tool without pole. BCK-200B: Black detector covers, box of 10. WCK-200B: White detector covers, box of 10. NOTIFIER® is a registered trademark of Honeywell International Inc. Bayblend® is a registered trademark of Bayer Corporation. 02008 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING MANUMC1lJtINt All specifications are subject to change without notice. QUALITY SYSTEMS For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203)484-7118. www.notifier.com Page 2 012- dn-6995:al • 05/08/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-100T photoelectric type smoke detectors. Model NP-100T has a 1350F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF 7272-0075:194 11-03-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or ;'.. recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division DN-7001 :B • Al -380 NOT.BGI2LX NOTIFIER® Addressable Manual Pull Station (4 For FireWarden Series Panels by Honeywell L lneuigenjAddr.s.ab!eDeyi oil -i - General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels. Because the NOT-BG12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. - Handle latches in down position and the word ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Construction Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. Specifications Normal operating voltage: 24 VDC. Maximum SLC loop voltagef28.0 VjbC. Maximum SLC loop currentI4jAj Ambient Temperature: 32°F to 120°F (0°C to 49°C) Relative Humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F) For use indoors in a dry location Installation The NOT-BG12LX will mount semi-flush into a single-gang, double-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NOT-BG12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). The NOT-BGI2LX Addressable Manual Pull Station Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1-99 on FireWarden-100-2, 1-50 for FireWarden-50). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. DN-70018• 10120/2008—Page 1 o12 Manual stations shall connect with two wires to one of the con- trol panel SLID loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. Back of station without door Terminal Connections: 1 SLC (-); 2 SLID (+) 1 C) C) - .......-.- i 1 I -- L_ ®_ - _ Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Patented: U.S. Patent No, D428,351; 6,380,846; 6,314,772; 6,632,108. BG12TR: Optional trim ring. 17021: Keys, set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: S692 MEA: 67-02-E Vol. IV CSFM: 7150-0028:199 FM Approved Detail of BREAKAWAY TAB* 14 15 0 A)T i 0 1 13032 02 LOOP LED ROTARY DECIMAL SWITCHES J *Do not remove tab. Notitier® is a registered trademark of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. ., We cannot cover all specific applications or anticipate all requirements. ENSIMERINC & MANUFACTURINS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2o1 2— DN-7001:13 • 10120/2008 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Fire Alarm Boxes LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Vladimir Kireyev (203) 484-6277 Fax (203) 484-7309 Vladimir.kireyev@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG- 12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBC- 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBC- 12SP, NOT-BG12LX, and NBG-12LXSP fire alarm pull boxes. All units except Model NBC- 12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBC-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG- 12LAOB and NBG-12LOB are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-1 0 back box. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. *Updated 08-11-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 11, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Monitor Modules dn-6999:bl jNOTPFIER® for FireWarden Series Panels by Honeywell General NMM.100(A), NMM-IOOP(A), NZM- lflfllAi and NflM.IOOIAI Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (NZM-100(A)). NMM-100(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to often be mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate, consecutive addresses in intelligent, two-wire systems. NMM-100(A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2, 01 -50 on Fire Warden-50. LED flashes during normal operation and latches on steady to indicate alarm. The NMM-100(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. NMM-100(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. Iii !tj (J_9 L-. . k \ NMM-100(A) (Type H) NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100(A) SPECIFICA TIONS Nominal operating voltag : 15 to 32 VDC. : Maximum current dra 5.0 m (. Don). Average operating curren/ crpA-L-aD flashing), 1 com- munication every 5 seconds, k-6OL.J Maximum IDC wiring resistance: 40 ohms. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125' (5.398 cm) deep box. NMM-IOOP(A) Mini Monitor Module Built-in type identification automatically identifies this device as a monitor module to the panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct Decade entry of address: 01 - 99 on FireWarden- 100-2. 01 -50 on FireWarden-50. dn-6999:bl • 11/19/09 - Page 1 of 4 ° 1415 ° 1 ADDRESS 0 . 81 13( \21 ,-'-. \2 1 51 9-6 L_- TENS ONES I [c\ T 1 1° J The NMM-100P(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P(A) is intended for use in intelligent, two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- ing device circuit for normally-open-contact fire alarm and security devices. NMM-100P(A) NMM-100P(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices, May also be used to monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the cir- cuit. NMM-100P(A) OPERATION Each NMM-100P(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). NMM-100P(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 40 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 400 pA. EOL resistance: 47K ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. NZM-1 00(A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade entry of address:, 01 - 99 on FireWarden- 100-2, 01 —50 on FireWarden-50. LED flashes during normal operation. LED latches steady to indicate alarm on command from control panel. The NZM-100(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (nor- mal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being moni- tored must be UL compatible with the module. NZM- 100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum lOG loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM- 100(A) OPERATION Each NZM-100(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/nor- mal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM- 100(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 ohms, Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. NDM-100(A) Dual Monitor Module The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices. The module has a single panel- controlled LED. NOTE: The NDM-100(A) provides two Style B (Class B) lOG cir- cuits ONLY Style V (Class A) IDC circuits are NOT supported in any application. NOM-100(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing). Maximum IDC wiring resistance: 1,500 ohms. Page 2 of 4— dn-6999:bl • 11/19/09 Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance: 40 Ohms. Temperature range: 32° to 120°F (01 to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5° (11,43 cm) high x 4" (10.16 cm) wide x 2.125° (5.398 cm) deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address 26", then it will automati- cally assign itself to addresses '26" and "27". NOTE: "Ones" addresses on the NDM-lOO(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SM8500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635 ULC: S635 FM Approved CSFM: 7300-0028:230 (NMM-100, NMM-100P, NZM-100); 7300-0028:237 (NDM-1 00) MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol. 3 (NDM-100) Product Line Information NOTE: "A" or suffix indicates ULC-listed model. NMM-100(A): Monitor module. NMM-100P(A): Monitor module, miniature. NZM-1 00(A): Monitor module, two-wire detectors. NDM-100(A): Monitor module, dual, two independent Class B circuits. SMBSOO: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 52304. dn-6999:bl • 11/19/09 - Page 3 of 4 Notifier® and Fire Warden® are registered trademarks and FireWatchm is a trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. ------ I We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I I INLINtEUNG A MANUFACTURING I I All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.nofifier.com Page 4 of 4— dn-6999:bl • 11/19/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:230 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, 12 Clintonville Rd, Northford CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-1 00 control modules. Refer to listees data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listees separately listed electrically compatible fire alarm control units. Refer to listees Installation Instruction Manual for details. XLF: 7300-0075:185 10-20-2004 . This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 15, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division dn-60304:a 0 NOTIFIER® and Series ZNH Horns byHoneywell General 'SNAP' Series Z Series ZRS Strobes, ZNS Horn Strobes The Wheelock Series Z notification appliances feature an easy snap on base that is designed to simplify the installation and testing of horns, strobes, and horn/strobes. The separate Series Z snap-on base can be pre-wired so circuit wiring can be fully tested before the appliance is installed and before the walls are covered. Once all surrounding work is complete, the appliance can be simply installed by snapping it on the base. Shorting contacts in the base, which provide continuity for cir- cuit testing, are permanently opened when the appliance is installed so any subsequent removal of the appliance will indi- cate a trouble condition on that circuit at the control panel when circuit supervision is enabled. The same base is used for all Series Z horns, strobes, and horn/strobes to provide con- sistent installation and easy replacement of appliances if required. A locking screw is also included for the appliance to provide extra secure installation. The Wheelock Series Z appliances incorporate the same dependable circuitry and high efficiency optics that are used in Wheelock RSS strobes, NS Horn/Strobes, and NH Horns that have the same high performance ratings. The Series Z appli- ances are compatible with all UL Listed Regulated" panels and all panels that are compatibility listed with Wheelock RSS, NS and NH appliances. Features EZ Mount SNAP design, with separate base plate provides ability to pre-wire the base and test the circuit wiring before the walls are covered. The base plate is protected by a disposable cover and the appliances can quickly snap onto the base after the walls are painted. Patented EZ Mount Universal Mounting Plate (ZBASE) uses single plate for ceiling and wall mount installations. Wall mount models feature field selectable candela settings of 15/30175/11 Ocd and 135/185cd. Ceiling Mount models feature field selectable candela set- tings of 1 5/30/75/95cd and 11 5/1 77cd. Strobes can be synchronized using the Wheelock SM or DSM Sync Modules or a power supply with built-in Sync Protocol. 12 and 24 VDC models with UL "Regulated Voltage": using filtered DC or unfiltered VRMS input voltage. Strobes produce one (1) flash per second over the "Regu- lated Voltage" range (ZNS, ZRS models). Selectable Continuous Horn or Temporal (Code 3) Tones with selectable 90 or 95 dBA setting (ZNH, ZNS models). Selectable 12 or 24 VDC in one appliance (ZNH model). ADA/NFPA/UFC/ANSI and OSHA 29 Part 1910, 165 com- pliant. a Series ZNS Series ZRS Elf .' 41 o Series ZNS Series ZRH WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. FAILURE TO COMPLY WITH ANY OF THE FOLLOWING INSTRUCTIONS, CAUTIONS AND WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes Strobes are designed to flash at one (1) flash per second minimum over their Regulated Voltage Range." All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series ZNS Strobe products are listed under UL Standards 1971 and 464 for indoor use with temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series ZNH horns are listed under UL Standard 464 for audible signal appliances (indoor use only). Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range." dn-60304:a • 5/6/08 - Page 1 of 4 Table 1: Series ZNS Rating per UL Standard 1971 Input Regulated Strobe Model Voltage voltage Range Candela VDC VDC/FWR (CD) ZNS-MCW 24 16.0-33.0 15/30/75/110 ZNS-MCWH 24 16.0-33.0 135/185 ZNS-MCC 24 16.0-33.0 15/30/75/95 ZNS-MCCH 24 16.0-33.0 115/177 Table 2: Series ZNS/ZNH Horn dBA Ratings Description Volume Reverberant dBA @l Oft per UL 464 Anechoic dBA @lOft I2VDC 24VDC I2VDC 24VDC Continuous Horn High 83 87 89 95 Low 76 81 84 90 Code 3 Horn High 79 82 89 95 Low 72 76 84 90 Table 3: Series ZRS UL Maximum Current* ZRS -Wall Mount ZRS - Ceiling Mount ZRS 24VDC Models MCW MCWH MCC MCCH 15cd 30cd 75cd 110cd 135cd 185cd 15cd 30cd I 75cd 95cd 115cd 177cd 16-33 VDC .060 .092 .0165 .220 .300 .420 f05- o'7 .189 .249 .300 1 .420 * UL maximum current rating is the maximum RMS current within the listed voiiange (16-33V for 24V units). For strobes the UL maximum current is usually at the minimum listed voltage (16V for 24V units). For audibles the maximum current is usually at the max- imum listed voltage (16V for 24V units). For unfiltered FWR ratings, see installation instructions. Table 4: Series ZNS UL Maximum Current* Series ZNS/ZNH 24VDC Audible Wall Mount Strobe Models Ceiling Mount Strobe Models ZNS-NCW ZNH-12/24 ZNS-MCWH ZNS-MCC ZNS-MCCH 15cd 30cd 75cd llOcd 135cd 185cd 16cd 30cd75cd 95cd ll5cd 17 c High (95) dBA 16-33 VDC 044 074 107 184 244 350 477i 082 124 Lö9 275 3501 477 Low (90) dBA .018 .066 .101 .177 .232 .306 _________ .429 .071 .114 .201 .261 .306 .429 Series ZNS/ZNH I2VDC Audible * UL maximum current rating is the maximum RMS current within the listed voltage range (16-33V for 24V units). For strobes the UL maximum current is usually at the minimum listed voltage (16V for 24V units). For audibles the maximum current is usually at the maximum listed voltage (16V for 24V units). For unfiltered FWR ratings, see installation instructions. ZNH-12/24 High (89) dBA 8-17.5 VDC 021 Low(84)dBA .012 Architectural/Engineering Specifications Audible/visual notification appliances shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. These appliances shall be listed under UL Standard 1971 (Stan- dard for Safety Signaling Devices for Hearing Impaired), and UL Standard 464 (Fire Protective Signaling). The appliances shall use a Patented Universal EZ Mount backplate that shall allow mounting to a single-gang, double-gang, 4-inch square, 4-inch octal, or a 31/2-inch octal backbox. Two wire appliance wiring shall be capable of directly connecting to the mounting back- plate. Continuity checking of the entire NAC circuit prior to attaching any audible/visual notification appliances shall be allowed. A dust cover shall fit and protect the mounting plate. The duct cover shall be easily removed when the appliance is installed over the backplate. Removal of an appliance shall result in an alarm condition by the Fire Alarm Control Panel (FACP). Strobe appliances shall produce a minimum flash rate of 60 flashes per minute (1 flash per second) over the Regulated Volt- age Range of 16 to 33 VDC and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The strobes shalt Page 2 of 4— dn-60304:a • 5/6/05 be available with 2 or 4 field selectable settings in one unit and shall be rated, per UL 1971 for up to 185cd for wall mounting and 177cd for ceiling mounting. The strobe shall operate over an extended temperature range of 32°F to 120°F (0°C to 49°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Horns and horn/strobes shall be listed for indoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal Code-3 output that can be synchronized. The horns shall have at least 2 sound level settings of 90 and 95 dBA. When synchronization of strobes or temporal Code-3 audibles is required, the appliances shall be compatible with the Wheelock Series SM and DSM Sync Modules or a power supply with built- in Sync Protocol. The strobes shall not drift out of synchroniza- tion at any time during operation. Audibles and strobes shall be able to be synchronized on a 2-wire circuit with the capability to silence the audible if required. If the sync module or power sup- ply fails to operate (i.e. contacts remain closed), the strobes shall revert to a non-synchronized flashrate. Wiring Diagrams From + + PRECEDING { To NEXT DEVICE - - } DEVICE orFACP orEOLR + - SIGNAL ZNS/ZNH APPLIANCE SM F + STROBE - STROBE A Strobe NAC Ns 1l H c Circuit (2 P , <-EOLR Audible Audible NAC 6601w1r2uwr,,i Circuit ZNS AND ZNH APPLIANCES SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT WITH AUDIBLE SILENCE FEATURE DSM QSYNC+ & SYNC- &+IN1 MINUS 1 + AUDIBLE SINGAL CIRCUIT OUT - AUDIBLE -®+ OUT 2 -Q- -)±IN2 I _J SIGNAL ' MINUS 2 CIRCUIT RETURN ZNS AND ZNH APPLIANCES SYNCHRONIZED WITH DSM MODULE DUAL CLASS "A" NAC CIRCUIT WITH NO AUDIBLE SILENCE FEATURE NOTE: ZNS/ZNH must be set on Code 3 horn tone to achieve synchronized temporal (Code 3) tone. Refer to installation instructions (P83983, P83600 respectively). NOTE: For detail using SM or DSM Sync Module refer to data sheet S3000 or installation instructions P83123 for SM and P83177 for DSM. dn-60304:a • 5/6/08 - Page 3 of 4 Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL Listed: E5946 Ordering Information Model Number U Strobe Candela Sync w/ SM, DSM 24 VDC 12 VDC Mounting Options Agency Approvals _ UL MEA CSFM FM BFP ZNS-MCW-FR 15/30175/110 X - B, D, E, F X =—= - - ZNS-MCW-FW 15/30/75/110 x X B, D, E, F X X X - - ZNS-MCWH-FR 135/185 X X B, D, E, F X x x - - ZNS-MCWH-FW 135/185 X x B, D, E, F X X X - - ZNH-R - X X X B,D,E,F X X X - - ZNH-W - X X B,D,E,F X X X - - ZNS-MCC-FR 15/30/75/95 X X B, D, E, F X X X - - ZNS-MCC-FW 15/30/75/95 X X - B, D, E, F X x x - - ZNS-MCCH-FR 115/177 X x B, 0, E, F X X X - - ZNS-MCCH-FW 115/177 X X - B, D, E, F- X X X - - ZRS-MCW-FR 15/30/75/110 X X - B, 0, E, F- X X X - - ZRS-MCW-FW 15/30/75/110 X X B, 0, E, F X X X - - ZRS-MCWH-FR 135/185 X X B, 0, E, F X X X - - ZRS-MCWH-FW 135/185 X X B, D. E, F x x x - - ZRS-MCC-FR 15/30/75/95 X 3T B, D, E, F X x x - - ZRS-MCC-FW 15/30/75/95 X X " B, D, E, F X X X - - ZRS-MCCH-FR 115/177 X X B, D, E, F x x ZRS-MCCl-I-FW 115/177 X X B. D, E, F X X X - - Lexan® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. ©2005 by Honeywell International Inc. All rights reserved, unauthorized use of this document is strictly prohibited. I O 9001 This document is not intended lobe used for installation purposes. We try to keep our product information up-to-dale and accurate. dl We cannot cover all specific applications or anticipate all requirements. ENCINEERINC MANRFACRINR All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 4 of 4— dn-60304:a • 5/6/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM , LISTING SERVICE LISTING No. 7125-0785:142 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 deborah.piserchia@cooperwheelock.com DESIGN: Models NH-12/24, NH-12/24R, and ZNH horns and Models NS-1215W, NS-121575W, NS-2415W, NS-241575W, NS-2430W, NS-2475W and NS-241 1 OW; NS4-12 15W, NS4- 121575W, NS4-24 15W, NS4-241 575W, NS4-2430W, NS4-2475W and NS4-241 low, NS-24MCW, NS4-24MCW, NS-24MCC, NS-24MCCH, ZNS-MCW, ZNS-MCC, ZNS- MCWH and ZNS-MCCH horn strobes. Model number may be followed by any two- alpha/numeric characters indicating lens, lettering and color. Units are synchronized or non-synchronized strobes. Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are ceiling mount only. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical-Strobe Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Horn: 8-17.5 VDC/FWR and 16-33 VDC/FWR Candela: 15=15cd, 157515/75cd on axis, 3030cd, 75=75cd, 110=110cd (Wall) NS-24MCW, NS4-24MCW, ZNS-MCW: Selectable 15cd, 30cd, 75cd, 110cd NS-24MCC, ZNS-MCC: Selectable 15cd, 30cd, 75cd, 95cd NS-24MCCH, ZNS-MCCH: Selectable 115cd, 177cd ZNS-MCWH: Selectable 135cd, 185cd Flash rate: 60 Flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. All units are for wall mount except for *Models NH-12/24R, NS-24MCC, NS-24MCCH, ZNS-MCC and ZNS-MCCH are for ceiling mount only. MARKING: Listee's name, model number, electrical/candela rating and UL label APPROVAL: Listed as audible and audible/visual signaling devices for use with separately listed electrically compatible fire alarm control units. Models with strobe lights are suitable for the hearing impaired. For indoor use only except for model NH-12/24 horn. All synchronization strobes shall be used with Models SM-12/24, SMX-12/24, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132). Refer to manufacturer's installation manual for details. NOTE: These appliances can produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. *Corrected 07-25-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Deborah Piserchia (732) 433-6001 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRSMCW *ZRSMCCH and *ZRSMCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 16-33VDCIFWR Candela 15=5cd, 1575=15/75cd on axis, 30=30cd, 75=75cd, 110110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRS.MCW: Selectable 15cd, 30cd, 75cd or ll0cd RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRS..MCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12/24, DSM-12124 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division