Loading...
HomeMy WebLinkAbout2210 FARADAY AVE; ; FPC2017-0160; Permitcity of PERMIT REPORT Carlsbad Print Date: 02/03/2022 Permit No: FPC2017-0160 Job Address: 2210 FARADAY AVE, CARLSBAD, CA 92008-7225 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Underground Fire Parcel #: Track #: Applied: 06/12/2017 Valuation: $0.00 Lot #: Issued: 09/27/2017 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check#: Inspector: Plan Check #: Final Inspection: Project Title: Description: CARLSBAD BACKFLOW UPGRAGE - 10' BACKFLOW FPContractor: HCI SYSTEMS INC 4585 MURPHY CANYON RD SAN DIEGO, CA 92123-4318 (909) 628-7773 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $733.00 Total Fees: $733.00 Total Payments To Date: $733.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov U AO S Carlsbad Municipal Water District - A Subsidiary District of the City of Carlsbad A 5950 El Camino Real - Carlsbad CA 92008 Ph. (760) 438-2722 Fax (760) 431-2658 Email backflowcarlsbadca.gov CARLSBAD Acct. No: 8303908 Date of Notice: MARCH 1, 2017 Service Address 2210 FARADAY AV Interval: 3 Location FIRE - Meter #42245859 CARLSBAD 2210 LLC % CUSHMAN & WAKEFIELD 3870 MURPHY CANYON RD STE 150 SAN DIEGO CA 92123 Make/Model AMES 3000 Size: 10 Serial No.: 3KL0828 Type: DCDA Mtr. Size/Num.: 1 1/2 ' 0015901167 User Code C GPS: RE: ANNUAL BACKFLOW RECERTIFICA TION NOTICE -DUE 30 DAYS FROM DATE OF NOTICE **FAILURE TO COMPLY WILL INCUR LATE FEES** AFTER 7 DAYS LATE $8.00 --AFTER 21 DAYS LATE $24.00 From the date of this notice, you will have 30 days in which to have your backflow assembly tested and certified. If repairs are needed, the assembly will require retesting before it can be certified. The enclosed tester list is provided as a convenience. If you choose a tester not shown on the enclosed list, please have the tester contact our office to verify they, meet the requirements. The testing company must also possess a valid City of Carlsbad business license. Only tests performed by testers meeting the requirements will be considered valid. The Field Testing & Maintenance Form provided by the District must be completed by the repair and test contractor, signed by the tester and the original returned to the District. Test forms from other agencies, nor the tester's own forms will be accepted. This form must be completed and returned to the District within 30 days from the notice date or your water service will be subject to termination. Date Tested: AWWA or ABPA Cert. No.: Gauge Serial No.:____________ Firm Name: Tester Name:_____________________________________ Telephone No.: PSI:_____________ Line Valve #1 - Replaced ( ) Line Valve #2 - Tight ( ) Leaked ( ) Replaced Reduced Pressure Principle Assembly Double Check Valve Assembly Check #1 Check #2 Tight ( ) Tight ( ) Apparent Drop Test Before Opened At Repairs Leaked ( ) Leaked ( ) Actual Drop Pass( ) Fail( New Materials and Repairs Made Apparent Drop Test After Tight ( ) Tight ( ) Opened At Repairs Actual Drop Pass( Name and Phone No. of Repair Person:_____________________________________________________ Test After Repairs Done By: Firm Name: Tester Name: Date: Gauge Serial No.: AWWA or ABPA Cert No.: Telephone No.: Tester's signature affixed to this form certifies the above to be true. Testers Signature: ORIGINAL MUST BE RETURNED TO THE DISTRICT city of Carlsbad Address: 1635 Faraday Ave. Carlsbad, CA 92008 Fire Prevention: Phone: (760) 602-4665 Fax: (760- 602-8561 Jacauelvn Lankhorsl (Fire Permit Technician) Phone No: (760) 602-2731 Office Hours: Monday - Thursday 7:30am - 5:30pm Friday 8:00am - 5:00pm City Submittal Requirements: (3) Drawings, (1) Submittal Booklet (City will keep (1) Drawing & (1) Booklet) Submittal Note: - 10 Days turn around (Not Over the Counter or Expedite Service at this time) - We can mail our drawings + application to the city. - Once plan has been approved, the city will let us know about the fees due (We can pay in person or use credit card authorization form) - Approved plans can be picked up at the same address or can be mailed back if postage has been provided to the city. Fees: Check Fee Schedule O Systems Inc. FIRE / LIFE SAFETY & LOW VOLTAGE SPECIALISTS California Contractor's License # 905493 Underground Material Submittal Prepared for: Carlsbad Double Check Detector Assembly Upgrade 2210 Faraday Avenue Carlsbad, CA 92008 FPC20I7-0160 2210 Faraday AVE Ontario • San Diego • Irvine • Northern California Corporate Office: 1354 South Parkside Place, Ontario, CA 91761 Phone: (909) 628-7773 FAX: (909) 628-7774 24-Hour Service: (877) 331-2084 Website:www.hcisystems.net ES-A-3000SS Scri P..r% AuioORS Ll A M E S Double Check Detector Assemblies FIRE Sizes: 21/2" - 12" (65— 300mm) Senes3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the reverseflowoffire protection system substances, i.e., glycerin wetting agents, stagnantwater and water of non-potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a drinking water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free* through the waterway. The double check detector assembly consists of two independently operat- ing, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam-check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable seat. There shall be no brass or bronze parts used within the cam-check valve assembly. The check valve seats shall be of molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shall con- sist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly: Noryl® Flange dimension in accordance with AWWA Class D. NoryP is a registered trademark of General Electric Company. It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. Contractor____ Approval Contractor's P.O. No. Representative - Features Cam-Check Assembly valve provides low head loss Short lay length is ideally suited for ret- rofit installations Stainless Steel body is half the weight of competitive designs reducing installa- tion and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of main- tenance No special tools required for servicing Compact construction allows for smaller vaults and enclosures Furnished with 5N x W bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - less shutoff valves OSY - UL/FM outside stem and yoke resil- ient seated gate valves OSY FxG - flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection CFM - cubic feet per minute GPM - gallons per minute meter Post indicator plate and operating nut available - consult factory "The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name - Job Location Engineer - Approval - Ames product specifications In U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com Pressure - Temperature Temperature Range: 33°F - 110°F (0.5°C - 43°C) Maximum Working Pressure: 175psi (12 bar) Capacity Flow curves astested by Underwriters Laboratory per UL 1469,1996. * Rated flow **UL Tested kPa psi 3" (80mm) * ** I__Il F. IIP! — IL 0 25 50 100 150 200 250 300 350 400 450 500 550 600 gpm 95 190 380 570 760 950 1140 1330 1520 1710 1900 20902280 1pm 15 Ips (6 mps kPa psi 4" (100mm) ** 62 9 41 6 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2280 2470 26602850 1pm 5 10 15 fps 1.5 3 4.6 mps I I A Standards ASSE 1048, AWWA C510-92, CSA B64.5, UL 1469 Approvals UL Classified (OSY only), FM (sizes 21/2 - 10, OSY only) HS 4 OUL o- We psi 6" (150mm) ** 103 15 83 12 62 9 41 6 21 3 0 100 200 300 400 500 600 700 800 900 10001100 1200 1300 1400 1500 gpm 380 760 1140 1520 1900 2280 2660 3040 3420 3800 4180 4560 4940 5320 5700 1pm 5 10 15 fps 1.5 3 4.6 mps kPa psi 8" (200mm) * ** 83 12 - 62 9 - - 41 6 213 0 250 500 750 1000 1250 1500 1750 2000 2250 250 gpm 950 1900 2850 3800 4750 5700 6650 7600 8550 9500 1pm 5 10 15 fps 1.5 3 4.6 mps kPa psi 10" (250mm) * ** 103 15 83 12 62 9 0-10 21 3 - 41 6 0 250 500 750 1000 1250 1500 17502000 2250 25003000 3500 gpm 950 1900 2850 3800 4750 5700 6650 7600 8550 9500 11400 13300 1pm 5 10 fps 1.5 3 mps kPa psi 12" (300mm) 110 16 - 97 14 83 12 69 10 558 41 6 284 14 2 0 5001000 1500 2000 2500 30DO 3500 4000 4500 gpm 1900 3800 5700 7600 9500 11400 13300 15200 17100 1pm 5 10 fps 1.5 3 mps r 0 0 SIZE (ON)IIJI0l80011I166 0181#181111 NET WEIGHT in. mm in, A mm in. C (OSY) mm D in. mm G in. mm L in. mm P in. mm w/Gates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16/e 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18/8 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22I4 578 41/2 114 10 250 22 559 141/2 368 240 109 73 33 6 150 481/2 1232 1 301/8 765 51/2 140 15 381 1 271/2 699 1 151/2 394 390 177 120 54 8 200 521/2 1334 1 373/4 959 6I4 171 15 381 1 291/2 749 1 181/2 464 572 259 180 82 10 250 551/2 1410 1 453/4 1162 1 8 200 15 381 1 291/2 749 1 191/2 495 1 774 351 190 86 12 300 571/2 1461 1 531/8 1349 1 91/2 241 15 381 1 291/2 749 1 21 533 1 1044 474 220 100 AL _ A M E S I19001 -20081 CERTIFIED I FIRE &WATERWORKS amesfirewater.com 6I ___ A Watts Water Technologies Company USA: Backflow- Tel: (916)928-0123 • Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 Latin America: Tel: (52) 81-1001-8600 ES-A-3000SS 1410 © 2014 Ames Fire & Waterworks MODEL 3500A0 SHOWN ABOVE ZURN Model 350DA WILKINS Double Check Detector Assembly Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Sizes 2 1/2 - 10" Horiz. &Vert) (12" Horizontal Only) ASSES Listed 1048 (Sizes 2 1/2" thru 12") GSA® Certified 1364.5 (Sizes 2 1/2" thru 8", & 12') AWWA Compliant C510 (Sizes 2 1/2" thru 12'), and C550 UL® Classified (Sizes 2 1/2" thru 12") C-UL® Classified (Sizes 2 1/2" thru 12") FM® Approved (Sizes 2 1/2" thru 10") NYC MEA 147-99-M Vol 4 (2-1/2" - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 12") Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4" Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless Steel, 300 Series Features Sizes: 2 1/2", 3", 4", 6", 8", 10", 12" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) Options (Suffixes can be combined) O - with OS & Y gate valves (standard) J L - less shut-off valves (flanged body connections) LM - less water meter - with remote reading meter - with gallon meter (standard) O CFM - with cu ft meter CMM - with cu meter meter 0 G - with groove end gate valves 0 FG - with flanged inlet connection and grooved outlet connection P1 - with Post Indicator Gate Valve GF - with flanged inlet connection and grooved outlet connection BG - with grooved end butterfly valves with integral monitor switches (2 1/2" - 10') -509 - with AWWA C509 gate valves Accessories Repair kit (rubber only) O Thermal expansion tank (Model XT) O OS & Y Gate valve tamper switch (OSY-40) Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. DIMENSION r"mate) _(app WEIGHT MODEL A BLESS E E E LESS Os&Y OS&Y BUTTERFLY 350DA A C wiWITH WITHGATE D OS&Y OS&Y F SHUTOFF GATE GATE VALVES SIZE BUTIERFLY VALVES OPEN CLOSED BUTtERFLY VALVES GROOVED VALVES VALVES VALVES VALVES FLANGED GROOVED in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. rrni in. mm lbs. j lbs. j lbs. jj lbs. 21/2 65 31 787 28 711 157/8 403 33141 95 9 229 173/4 451 153/8 391 81/4 210 31/2 89 68 31 178 81 160 73 140 64 3 80 32 1813_ 28112 724 157/8 403 33/41 95 9 229 201/4 514 17 _ L32 81/2 216 31/2189 68 31 19B 90 . 150 68 120 54 4 100375/8956328/9835191/249541/21149229221/2572181/446492296152106 48 296 134282 6 150 443/4 1137 375/8 956 231/2 597 6 152 101P 267 301/2 775 241/4 616 101/4 260 7 178 180 82 480 218 454 216374170850386802 M-nia 10 250633/41619577/81470373/4 959 10 8200603/4l54537/81369373/4959102541230537940281/272412305 ~87/8 254 12 305455/61159 343/4 883 13 330 216 404 183 1222 554 1156 12 30066Vl68a n/a 38 965 10 12541 12 1 3051 53 4640V229 n/a n/a 2264632i023736 n/a Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. H Date: 1/17 Document No. BF-350DA Patent No. 5, 913.331 Product No. Model 350DA Page 1 of 2 PROTECTIVE VERTICAL INSTALLATION - Flow Characteristics MODEL 350DA 21/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (us) 12.6 25.2 37.9 O Rated Flow (ctahlihed by approval agencies) 50.5 rmcz - LEIB 800 157.7 _____________________________ 103 U) 69 Ae U)— ________ 34o W 0 0 500 1000 FLOW RATES (GPM)1 2000 2500 MODEL 350DA 10" & 12" (STANDARD & METRIC) FLOW RATES (I/s) 0.0 31.5 63.1 94.6 126.2 157.7 189.3 220.8 252.4 283.9 15 10 a.. 0 200 400 600 FLOW RATES (GPM) MODEL 350DA 6" & 8" (STANDARD & METRIC) 0.0 31.5 631 FLOW RATES (us) 94.6 126.2 v) 15 —J 6' 10 IL A 103 /) O 69 34g iy 0 500 1000 1500 2000 2500 3000 3500 4000 4500 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 1 5288 OUTDOOR INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350DA. Zurn Industries, LLC I Wilkins 1747 commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2