Loading...
HomeMy WebLinkAbout7660 EL CAMINO REAL; ; FPC2019-0178; PermitPERMIT REPORT C 4LClty of arlsbad Print Date: 02/03/2022 Permit No: FPC2019-0178 Job Address: 7660 EL CAMINO REAL, CARLSBAD, CA 92009-7901 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2165800100 Track #: Applied: 07/31/2019 Valuation: $0.00 Lot #: Issued: 08/12/2019 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check U: Final Inspection: Project Title: Description: GELSONS MARKET- PANEL REPLACEMENT Applicant: FPContractor: ADT LLC ADT LLC ROBERT CARO P0 BOX 310702 3830 CALLE FORTUNADA BOCA RATON, FL 33431-0702 SAN DIEGO, CA 92123-1825 (561) 989-7919 (619) 514-8481 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov www.boschsecurity.com 0 BOSCH Invented for life Fully integrated intrusion, fire, and access control allows users to interface with one system instead of three Conettix IP-based communication options provide high-speed, secure alarm transport and control through connection of wired and/or wireless cellular network interfaces Up to 8 programmable areas each supporting both with perimeter and interior points with your choice of touch screen, ATM style, or LED keypads 75 points with flexible configuration options to meet multiple installation requirements OPTIONAL GV4 version 2.00 firmware upgrade available (NEW) GV4 panels are the premier commercial control panel line from Bosch. GV4 panels integrate intrusion, fire and access control providing one simple user interface for all systems..With the ability to adapt to large and small applications, the D7412GV4 provides up to 75 individually identified points that can be split into 8 areas. The control panel includes a communicator that sends events to selected public switched telephone network (PSTN), IP network, or cellular network destinations through four programmable route groups. With the D7412GV4 you can: Monitor alarm points for intruder or fire alarms while operating keypads and other outputs Program all system functions local or remote using Remote Programming Software (RPS) or by using basic programming through the keypad. Add up to two doors of access control using the optional D9210C Access Control Interface Module. Programmable Outputs 2 A alarm power at 12 VDC 1.4 A auxiliary power at 12 VDC Four alarm-output patterns Programmable bell test System Response High-performance micro-controller provides industry-leading system response High-speed device bus (NEW) 31 custom point indexes, including fire supervisory Selectable point response time Cross point capability Fire alarm verification Fire inspector's local test Watch mode Scheduled events (SKEDs) arm, disarm, bypass and unbypass points, control relays, control authority levels, and control door access User Interface Supervision of up to 16 keypads (up to 32 unsupervised keypads can be used) Remote Programming Software (RPS) Lite allows end users to perform control panel management tasks - Add/Delete/Change user passcodes and authorities, view and print the panel history event log 2 1 D7412GV4 Series Control Panels Custom keypad text is fully programmable, including remote programming Full function command menu including Custom Functions Authority by area and 16-character name for each user 14 custom authority levels control user's authority to change, add, or delete passcodes or access control credentials; to disarm or bypass points; and to start system tests Area Configurations Area programming offers a wide selection of different system configurations. Each area is assigned an account number to define annunciation, control, and reporting functions. Multiple areas can be linked to a shared area which is automatically controlled (hallway or lobby). Area arming can be conditional on other areas (master or associate). Any area can be configured for perimeter and interior arming, not requiring a separate area for this function. Custom Functions For added convenience, Custom Functions can be programmed to eliminate keystrokes for users allowing the installer to program an easy command for a complicate function. For example, a custom function can be written to bypass a group of points and arm the system, allowing the user to perform this function with one easy command. This can be used to control a particular room, or even a single door allowing customized access. In additions, Custom Functions can be activated with a token or card, or automatically as a scheduled event (SKED) providing further flexibility and ease of use. Door-Activated Custom Function A custom function activates when user credentials are presented to a D9210C Access Control Interface Module door controller's reader. The custom function behaves as though the user performed a function at the keypad associated with the door controller. Passcode Security For high security applications, GV4 can be configured for several different passcode options. Dual Authentication requires a user to enter their passcode and also use a token or card (NEW). Two-Man Rule - Requires two people with two unique passcodes to be present at the time of opening. Early Ambush - Allows users to verify that the facility is safe by requiring two passcode entries at different keypads within the same area, sending a duress event if the user does not enter the passcode a second time after inspecting the premises. Easy Exit Control The D7412GV4 Control Panel changes from one armed state to another armed state without disarming. For example, if you change the state from Perimeter Arm to Master Arm, the control panel complies and reports the change. Easy Exit Control reduces the number of keystrokes, simplifying system operation. Programmable Passcode-controlled Menu List The system prompts users to enter a passcode prior to viewing the keypad menu. The keypad display shows the user the menu options allowed according to the user's authority level. Passcode-controlled menus provide users only with the options and information pertinent to them, simplifying system operation. Flexible Control The system provides the flexibility to select added convenience or high security. For example, you can restrict passcode arming and disarming to a keypad's immediate local area, even if the user has access to other areas. This is particularly useful for high security areas, where a user may have access to the area, but would prefer to only disarm the area individually rather than with the rest of the system. Another option is to program the system to disarm all areas the user can access from any keypad. Invisible Walk Test A menu item allows the user to test invisible 24-hour points within the scope of the keypad without sending a report to the central station. System Users The system supports up to 399 users, each can have a passcode, an access token and a wireless keyfob. User passcodes contain three to six digits. Passcodes can be assigned to one of 14 customized authority levels in each area and can be restricted to operate only during certain times. Communication Formats The D7412GV4 Control Panel prioritizes and sends reports in Contact ID or Modem lila2 communications formats to four route groups. Each group has a programmable primary and backup destination. The D7412GV4 provides flexible communications for most central stations with reporting capabilities such as: Individual point numbers Opening or closing reports by user and area number Remote programming attempts Diagnostic reports UP Communication The D7412GV4 uses the B420 Ethernet Communication Module, DX4020, and/or the ITS-DX4020-G Cellular Communicator to communicate with the Conettix 06600 and D6100i Communications Receiver/Gateways. Using Conettix IP communication offers a secure path that includes anti-replay/anti- substitution features and provides enhanced security with encryption. The B420, 0X4020 and ITS-DX4020-G can all be used for remote programming. GV4 is the first Security Control panel to support DNS (Domain Name System) for both remote programming and central station communication. DNS provides ease of use, eliminating the need to use static IP addresses as your reporting destination, and accommodates a simple solution for central station disaster recovery. 3 1 D7412GV4 Series Control Panels IP Setup is available via the installer keypad menus and the remote programming software, eliminating the need to use complicated internet programming tools such as ARP and Telnet (NEW). Communication Paths D7412GV4 Control Panels accommodate up to four separate destinations for primary, alternate, and backup receivers for automatic test reports. When resetting alarms or arming or disarming a system, the user is identified by name and number. Firmware Updates (NEW) Remote firmware updates using the RPS Firmware Update wizard through the lP connection (8420 Ethernet Communication Module) as well as an on-site flash update key, provides for easy feature enhancements without replacing ROM chips. *For GV4 version 2.00 firmware update information, refer to the, "GV4 version 2.00 firmware updates" datasheet to learn more about key enhancements, and supported products. A wide variety of input options Each point: Accommodates normally-open (NO) and normally-closed (NC) devices with end-of-line (EOL) resistor supervision. Is programmable for fire, fire supervisory, or intrusion application. Can be hard-wired, addressable, or wireless. Security and Fire Detection The D7412GV4 Control Panel provides eight on-board points, and up to 67 additional off-board points. You can program individual points to monitor all types of burglar alarms, fire alarms, and supervision devices. Access Control The D7412GV4 provides custom door strike, point shunt and auto disarming response by area. There are 14 panel-wide access levels with both manual and scheduled control. Store, view, or print access events such as: Access granted No entry Request-to-enter Request-to-exit Wireless Interface The B820 SD12 Inovonics Interface Module connects an Inovonics EN4200 Serial Receiver to the control panel SD12 bus, allowing this UL Listed (NEW) wireless system to be programmed locally via the panel keypad, as well as remotely through RPS. Event Log The event log stores up to 1,000 local and transmitted. events. The event log includes time, date, event, area, point, user number, and transmission status (NEW). View the event log from a keypad or use RPS to remotely retrieve event information. RPS operators can retrieve events periodically using one call, rather than receiving several calls each day. When the event log reaches a programmed threshold of stored events, it can send an optional report to a receiver. Scheduled Events (SKEDs) The internal clock and calendar start individually scheduled events (SKEDs). SKEDs perform functions such as arm or disarm, relay control, or point bypassing. The D7412GV4 Control Panel offers: 40 scheduled events with up to 25 different functions Eight opening windows and eight closing windows Eight user windows Day-of-week, date-of-month, or holiday only schedules Four holiday schedules of 366 days each (leap year) Fire Test When a user activates Fire Test Mode, the control panel suppresses all reports to the central station. The keypad and annunciator show all testing data. An automatic sensor reset feature saves time; you do not need to reset the sensors manually. At the end of test, the keypad shows the number of untested points. Programming, Diagnostics and Controls Installers can program locally or remotely through RPS as well as basic keypad programming. A programmable system passcode prevents unauthorized remote programming. Two Data Buses GV4 provides 2 data buses which support a wide array of components. The SDI bus supports keypads access and communications modules and also allows connection of existing components in a retrofit application. The new SDI2 bus supports input and output devices as well as a new interface module, and an Ethernet communicator. SD12 allows these devices to be mounted up to 1000 ft (305 m) from the control panel, providing installation convenience and flexibility. Commercial Fire Alarm Support Suitable for Commercial Fire (UL 864, 9th Edition) applications. USA: UL 365 Police Station Connected Burglar Alarm Units and Systems UL 609 Local Burglar Alarm Units and Systems UL 636 Holdup Alarm Units and Systems UL 864 Control Units and Accessories for Fire Alarm Systems (Commercial Fire) UL 985 Household Fire Warning System Units UL 1023 Household Burglar Alarm System Units UL 1076 Proprietary Burglar Alarm Units and Systems UL 1610 Central Station Burglar Alarm Units 4 1 D7412GV4 Series Control Panels I ANSI/SIA CP-01:2010 False Alarm Reduction CSFM California Office of The State Fire Marshall 7165-1615:0242 Control Unit (Commercial) FM 3010 FCC Part 15 Class B, Part 68 Region Certification USA - FDNY- #6102 UL 864 9th Edition [D9412GV4, CoA 07412GV4] UL AMCX.S1871, Central Station Alarm Units; AMTB. S1871, Control Panels, SIA False Alarm Reduction; AOTX.51871, Local Alarm Units; APAW.51871, Police Station Alarm Units; APOU.51871, Proprietary Alarm Units; NBSXS1871, Household Burglar Alarm System Units; UOJZ.S1871, Con- trol Units, System; UTOU.S 1871, Con- trol Units and Accessories, Household System Type CSFM 7167-1615:0243 CSFM 7165-1615:0242 Brazil ANATEL 1083-12-1855 Compatible Products Keypads D1265 Touch Screen Keypad D1255 Series Keypads (01255,01255W, 01255B, 01255R6, 01265) D1260 Series Keypads (D1260, 01260W, 01260R, D1260BLK, 01260B) 01256RB Fire Keypad D1257RB Remote Fire Alarm Annunciator 0720 Series Keypads (0720, 0720W, 0720R, 0720B) 0279A Independent Zone Control Detectors 0278S Four-wire Addressable Detector Base, 12 VDC 0285/TH Photoelectric Smoke Detector Heads D298S Addressable Detector Base, 24 VDC 07050 Series Addressable Photoelectric Smoke and Smoke Heat Detector Heads F220-B6PM/S 12/24 VDC Addressable Detector Bases with POPITs FCC-380 Carbon Monoxide Detector MX7751 Addressable PIR Detector MX794i Long Range Multiplex PIR Detector MX934i Addressable PIR Detector MX938i Addressable PIR Detector ZX776Z PIR Detector ZX794Z Long Range PIR Detector ZX835 lrilech Microwave/PIR Detector 7X935Z PIR Detector ZX938Z PIR Detector ZX970 PIR/Microwave Detector Bosch conventional detectors, including Professional Series, Blue Line Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount motion detectors, as well as glass break, seismic, request-to-exit, photoelectric, heat, and smoke detectors. Enclosures D8103 Universal Enclosure 08108A Attack-resistant Enclosure D8109 Fire Enclosure Magnetic Contacts Bosch magnetic contacts include recessed, terminal connection, miniature, overhead door, and surface mount. Modules Conettix B426 Ethernet Communication Module (NEW) B208 Octo-input Module B308 octo-output Module B520 Auxiliary Power Supply Module (NEW) B820 S012 Inovonics Interface Module Conettix B420 Ethernet Communication Module Conettix ITS-0X4020-G Cellular Integrated Communicator Conettix 0X4020 Network Interface Module Conettix DX401OV2 USB/Serial Interface Module Conettix C900V2 Dialer Capture Module 0113 Battery Lead Supervision Module D125B Dual Class B Initiating Module D127 Reversing Relay Module 0129 Class A Initiating Module 0130 Auxiliary Relay Module 0185 Reverse Polarity Signaling Module 0192G Notification Appliance Circuit Module 0928 Phone Line Switcher 05060 MUX Programmer 08125 POPEX Point Expander 081280 OctoPOPIT Eight-point Expander 5 1 D7412GV4 Series Control Panels D8125MUX Point Expander 081251NV Wireless Interface Module 08129 Octo-relay Module D8130 Door Release Module D9127 Series POPIT Modules 09131A Parallel Printer Interface Module D92 10C Access Control Interface Module D57432 Eight-input Remote Module DS7457i Series Single-zone Multiplex Input Modules DS7460i Two-input Module DS7461i Single-input Multiplex Module DS7465i Input and Output Module ICP-SDI-9114 SDI Splitter Transformers 01640 Transformer 01640-CA Transformer Programming RPS or RPS-LITE Remote Programming Software Readers ARD-1310 iCLASS Mullion Reader ARD-1340 iCLASS Switchplate Reader ARD-RK40-09 iCLASS PIN Reader ARD-VSMART CLASS Reader D8223 Prox Pro Reader 08224 Mullion Reader D8224-SP Switch Plate Reader 08225 Mini Mullion Reader 0830 1W Low-profile Proximity Readers Wireless 8820 SDI Inovonics Interface Module SD12 Inovonics Interface and Receiver Kit. Includes 8820 and EN4200 (ENKIT-SDI2) EN 1210 Universal Transmitter (Single-input) EN12 10E0L Universal Transmitter with EOL Resistor EN 1210W Door-Window Transmitter with Reed Switch EN 1215E0L Universal Transmitter with Wall Tamper, Reed Switch, and EOL Resistor EN 12230 Water-resistant Pendant Transmitter (Double-button) EN1223S Water-resistant Pendant Transmitter (Single-button) EN1224-ON Multiple-Condition Pendant Transmitter EN 12330 Necklace Pendant Transmitter (Double-button) EN 1233S Necklace Pendant Transmitter (Single-button) EN 12350 Beltclip Pendant Transmitter (Double-button) EN1235DF Fixed-location Transmitter (Double-button) EN1235S Beltclip Pendant Transmitter (Single-button) EN 1235SF Fixed-location Transmitter (Single-button) EN 1247 Glass-break Detector Transmitter EN 1249 Bill Trap Transmitter EN1242 Smoke Detector Transmitter EN 1260 Wall Mount Motion Detector EN1261HT High Traffic Motion Detector EN1262 Motion Detector with Pet Immunity EM 1265 360° Ceiling Mount Motion Detector EN4200 Serial Receiver EN5040-T High Power Repeater with Transformer The D7412GV4 includes the following parts: Quant. Component 1 D7412GV4 Board 1 Mounting Skirt 1 Faceplate with D7412GV4 Label 1 Literature pack Installation Instructions Owners Manual Release Notes 1 Literature CD containing all product literature The available kits come with the parts indicated in the following table: Kits Components -A -B -C -D D7412GV4 Board 1 1 1 1 0101 Lock and Key Set 1 1 1 O1O1F Lock and Key Set 1 0122 Dual Battery Harness 1 0161 Dual Modular Phone Cord 2 D928 Dual Phone Line Switcher 1 01640 Transformer 1 1 1 06103 Enclosure 1 08103 Enclosure 1 08108A Attack-resistant Enclosure 1 6 I D74123V4 Series Control Panels D8109 Fire Enclosure 1 Technical specifications Communications Telephone • One telephone line Connection: D928 Dual Phone Line Module required for two telephone lines Environmental Considerations Relative Humidity: 5% to 93% at +30°C (+86°F), non-condensing Temperature (Operating): 0°C to +50°C (+32°F to +122°f:) Number of... Areas: 8 Card Readers (Doors): 2 Credentials (Tokens): 399 Custom Functions: 4 Events: Up to 1000 Passcode Users: 399. plus 1 service passcode Parallel Printers: 1 Points: 75 (8 on-board, up to 67 off-board) Programmable Relay Outputs: 67 RF Points: 67 SKEDs: 40 Power Requirements Current Draw (Maximum): 300 mA Output (Alarm): 2Aat12VDC Output (Auxiliary, Continuous 1.4 A at 12 VDC nominal Power, and Switched Auxiliary combined): Voltage (Operating): 12 VDC nominal Voltage (AC): 16.5 VAC 40 VA plug-in transformer (D1640) Trademarks Inovonics is a trademark of Inovonics Wireless Corporation. D7412GV4 75 Point Control Communicator Order number D7412GV4 D7412GV4A Attack-resistant Package Contains one PCB, one transformer, and one attack- resistant enclosure. Order number D7412GV4-A D7412GV4-B Fire/Burglar Package Contains one PCB, one dual battery harness, two telephone cords, one telephone line switcher, one transformer, and one fire enclosure. Order number 07412GV4-B D7412GV4-C Standard Burglar Package Contains one PCB, one lock and key set, one transformer, and one universal enclosure. Order number D7412GV4-C D7412GV4-D Burglar PAckage Contains one PCB, one lock and key set, one transformer, and one D6103 Enclosure. Order number D7412GV4-D Accessories SDI2 Inovonics Interface and Receiver Kit Kit containing B820 and EN4200 for use on SD12 bus panels. Order number ENKIT-SDI2 D928 Dual Phone Line Switcher Allows the control panel to operate over and supervise two separate phone lines. Only one 0162 phone cord is supplied. Two additional 0161 or D162 phone cords are required. Order number D928 D101 Lock and Key Set Short-body lock set with one key supplied. Uses the D102 (#1358) replacement key. Order number D101 D122 Dual Battery Harness Harness with circuit breaker. Connects two batteries to a compatible control panel. Order number D122 D122L Dual Battery Harness with Long Leads Color-coded harness with circuit breaker and leads measuring 89 cm (35 in.). Connects 12 V batteries to compatible control panels. Order number 0122L D126 Standby Battery (12 V, 7 Ah) Sealed lead-acid standby and auxiliary rechargeable power supply. Order number D126 D1218 Battery (12 V, 18 Ah) A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors Order number D1218 7 1 D7412GV4 Series Control Panels D1224 Battery (12 V, 26-28 Ah) A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors. Order number D1224 D1238 Battery (12 V, 38 Ah) A 12 V sealed lead-acid battery for standby and auxiliary power with two bolt-fastened terminals. Includes hardware for attaching battery leads or spade connectors. Order number D1238 D137 Mounting Bracket Used to mount accessory modules in 08103, D8108A, and D8109 enclosures. Order number D137 D138 Mounting Bracket, Right Angle Used to mount accessory modules in D8103, D8108A, and 08109 enclosures. Order number D138 D1640 Transformer System transformer rated at 16.5 VAC, 40 VA. Order number D1640 D8004 Transformer Enclosure For applications such as fire alarm that might require a transformer enclosure. Order number 08004 D9002-5 Mounting Skirt Mounts inside 08103, 08108A, and D8109 enclosures. Can accept up to six standard 7.62 cm x 12.7 cm (3 in. x 5 in.) cards. Order number D9002-5 DuO Tamper Switch Screw-on tamper switch that fits all enclosures. Shipped in packages of two. Order number DuO ICP-EZTS Dual Tamper Switch Combination tamper switch with a wire loop for additional tamper outputs. Order number ICP-EZTS D8108A Attack Resistant Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). UL Listed. Includes lock and key set. Requires the 02402 Mounting Plate. Order number D8108A D8103 Enclosure Grey steel enclosure measuring 41 cm x 41 cm x 9 cm (16 in. x 16 in. x 3.5 in.). Order number D8103 D8109 Fire Enclosure Red steel enclosure measuring 40.6 cm x 40.6 cm x 8.9 cm (16 in. x 16 in. x 3.5 in). UL Listed. Includes a lock and key set. Order number D8109 Software Options RIPS Kit (USB) Account management and control panel-programming software with USB security key (dongle). Order number 05500C-USB 8 1 D7412GV4 Series Control Panels I Represented by, Americas, Botch Security Systems, Inc. 130 Perinton Parkway Fairport, New York, 14450, USA Phone: 51 800 289 0096 Fax: +1 585 223 9180 security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, AMcas Bosch Security Systems B.V. P.O. Boo 80002 5617 BA Eindhooen, The Netherlands Phone: 13140 2577 284 Fax: *31402577 330 omea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific, Robert Bosch (SEA) Pie Ltd, Security Systems 11 Bishan Street 21 Singapore 573943 Phone: +65 6571 2808 Fax: 065 6571 2699 apr.securitysystems@bosch.com ww-w.boschsecurity.asia China, Bosch (Shanghai) Security Systems Ltd. 201 Building, No. 333 Fuquan Road North l8P Changning District, Shanghai 200335 China Phone *862122181111 Fan: *86 21 22182398 www.boschsocurity.com.cn America Isobar Robert Bosch Ltdu Security Systems Division Via Anhanguera, Km 98 COP 13065-900 Campinas, Sao Paulo, Brazil Phone: *55 19 2103 2860 Fax: +55 19 2103 2862 a1.securitysystems@bosch.com www.boschsecurity.com C Bosch Security Systems 2013 Data subject to change without notice 2495670155 1 on. V8, 30. Jan 2013 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL I; FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1615:0242 Page 1 of 2 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: BOSCH SECURITY SYSTEMSI30 Perinton Parkway, Fairport, NY 14450 Contact: Peter Namisnak (585) 678-3655 Fax (585) 678-3263 Email: peter.namisnak©us.bosch.com DESIGN: Models D7412GV4 and D9412GV4 fire alarm control units. Inherently power-limited; remote station, central station and local service. Refer to listee's data sheet for detailed product description and operational considerations. System components: D122/0122L; Dual Battery Hardness D12513; Powered Loop Interface Module 0928; Dual Phone Line Switcher Module Dual Class A Initiating Circuit Module Relay Module 0192G; Notification Appliance Circuit Module 01640; Class 2 Transformer 08004; Transformer Enclosure 08125MUX; POPEX Module 08129; OctoRelay Module D8130; Door Release Module D9210B, D921OBC, D92I0BLC, D9210C; Access Control Interface Module DX4020, B420; Network Interface Card ITS-DX4020-G; GPRS/GSM IP Communicator 091271/D9127U; POPIT Module D8128D; OctoPOPIT Module D1255RB/D1256RB/D1257RB; Keypads/Annunciators D8125; Zone Expander Module 09131A; Parallel Printer Interface Module 06600; Receiver 28010 (27 K Ohm)/15-03130-004(1 K Ohm)! 15-03130-005(560 Ohm)/25899 (2.21 K Ohm)i; EOLR Resistors D8103/D8108/08108A; Enclosures ICP-SDI-91 14; SDI Splitter/Isolator Module B208; Input Module B308; Output Module D57432, DS7457iF, DS7460i, DS7461i, DS7465i; Multiplex Modules B440, B441, *B443; Cellular Modules B450; Interface Module 08109, BATB-40, BATB-80; Enclosures *Revision 09-20-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does-not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-1615:0242 Page 2 of 2 INSTALLATION: In accordance with the listees printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. Refer to listees Installation Instruction Manual for details. These control units can generate a distinctive three- pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturers installation instruction manual for details. Authority having jurisdiction shall be consulted prior to installation. These control units meet the requirements of UL Standard 864, 9th Edition. 11 *Revision 09-20-16 dc ~ Oz This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not .. --! an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division