Loading...
HomeMy WebLinkAbout5545 FERMI CT; ; FPC2018-0013; PermitPERMIT REPORT CL7city of Carlsbad Print Date: 02/03/2022 Job Address: 5545 FERMI CT, CARLSBAD, CA 92008-7324 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0013 Status: Closed - Finaled Applied: 01/10/2018 Issued: 01/30/2018 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: Project Title: Description: TAYLORMADE PGA & KIA BUILDOUT - FIRE ALARM -INSTALLING 2 NEW INTERFACE MODULE FOR NEW DUCT DETECTORS Applicant: iii ENTERPRISES SALOMON GOMEZ 115 MARKET PL ESCONDIDO, CA 92029-1353-SAN DIEGO (760) 747-3050 x216 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov F2.ot- OOL3 ii FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS TAYLOR MADE PGA & KIA BUILDOUT 5545 FERMI COURT CARLSBAD, CA 92008 FIRE ALARM SYSTEM MATERIAL DATA SHEETS 1"1130 J [ 1it1 9 THE INDUSTRY'S LEADING ADDRESSABLE TECHNOLOGY V-Flex is the patented polling loop technology that literally defines price and performance on a simple pair of wires. By using two wires instead of four, V-Flex offers significant advantages over home run wiring or the conventional four-wire multiplex—providing economical expansion of peripheral devices and point identification to your central monitoring station. Benefits Reduced Costs Since each V-Flex sensor can be installed using two wires for power and data—including existing wiring in many cases—costs are substantially reduced. Reduced Power Consumption V-Flex devices draw minimal amounts of current, minimizing the need for auxiliary power supplies. Fast, Accurate Identification and Response Point ID allows you to quickly and easily pinpoint the source of alarm or trouble from the keypad and communicate the information to the proper authorities—and lets you bypass protection at any specific point. Reduced Time and Labor V-Flex offers a labor and time-saving maintenance feature that gives you the ability to diagnose and pinpoint defects. As a result, installation and service professionals can arrive at the site already knowing the exact location of the problem. Service calls become much more efficient, saving you the time and labor costs associated with repeat visits. Reduced Maintenance Costs V-Flex can initiate functional smoke detector testing from a VISTA-32FB, VISTA-128FBP or VISTA-250FBF series system keypad—automatically logging results locally and sending them to a monitoring center. This drastically reduces system maintenance costs when annual tests or inspections are performed. Honeywell's V-Flex addressable technology offers many new and exciting innovations while fully supporting existing addressable loop products. You'll experience efficiencies in installation and reliability that will add up quickly on your bottom line. Begin experiencing the V-Flex advantage today! I ACC ESSORI ES 41 01 SN Relay Module Form C contacts rated ' at 2A, 28\IACNDC with contact supervision DT7500SN V-Plcx DUAL TC Motion Sensor '35' or 50' (un or 15m) enses Pattern containment and pattern shaping through K-Band microwave technology 0,50,100 lbs.0, 23, 45 Kg) selectable pet immunity with optional lens 5193SD/5193SDT One Piece Photoelectric Smoke Detector 5193SDT feaures (1350F/570C) neat sensor 4959SN Addressable I Overhead Door Contact Rugged aluminum housing and adjustable Ubracket type magnet 3:andard gap 2' E1mm) Tamper 4193SN/42935N Micro-miniature V-Plex Adapter Makes any hardwired cevice V-Plex ready Built-in serial number for addressing One superVsed, one unsupervisec zone 1S2500SN • V-Plex PIR Motion Sensor 35' or 50 (urn or 15m) enses J, 40, 80 Its (0, 18, 36 Kg) selectable pet immunity with optional lens 269St V-Plex Holdup Switch Fully supervised - Reset key for testing and -eset of alarm - •• Stainless steel protective cover - 49395N Addressable Surfaoe Mount Contact - Traditional "39" style with snap on cover to conceal . mourting screws Stafldard gap: 1.25". (32m-,n) = 5'(1.5m)CLII jacketed cable 41903N iWo Zone Remote Point Module DIP switch programmale - Left Zone-EOLR supervised, open or closed circuit sensors • Rignt Zone-unsupervised. - - closed circuit sensors - FG1325SN FlexGuarc 1ex3ore signal . processor Selectable sensitivity Easy installation with FG-701 Tester NI) minimum range '25 (9.6m) max range - 4191 5N-WH Recessec . -410 1,2(12.7mm) - diameter case . . S:andard gap: - 7;8" (22mm) Ptgrammable recessed contact with bjilt-in RPM (Remote' Pont Module) Also available with steel door adapter One ass-b /style B EOLR supervised aux. input zone. Operating and power ano communication with control via V-Pex loop 4208SNF Universal Class A& Class B Expander Module Provides 'p to six class B superv. sad zones and converts two panel zones to class A supervised zones Powered from addressable oop or DC power sLpply Seral number adc.ressing v.a DIP s'Mzch 4297 Polling Loop Extender Module so ates and protects diffeent areas of protection Exter ds loop distance Separate DC input, no loop current drain 4208SN Universal Eight Zone Remote Point Module Remote expansion zcre mooule Supports serial numoer application VISTAKEY Access Control Now, you can quickly and easily add access control - every time you install a VISTA commercial security system. VistaKey maximizes security investments by integrating access control, intrusion detection and fire detection into a single system. You can offer your customers 1-15 doc:rs of seamless integration, and.a unique combination of security and access control features: Arms and disarms security system with access card Conveniently connects to the V-Flex bus Tracks employee door entry and locks/unlocks doors on schedule Restricts access based on job function, time or locatior Events can be recorded to the VISTA event log; = printer optional S VPLEXVSl V-Plex ShortIsolator - • Detects and isolates polling - - loop branches with complete - - •, or resistive shorts, and overload or defective polling loop devices on initial - powerup Can be used to isolate = - burglary devices from fire 1: devices, increasing life safety and protection LED indithtOr reduces troubleshooting time and nainteharce bosts Powerd dirbty from tt'e V-Flex two-wire polling loop i an be placed on any major or minor branch in any configliratonior the polling loop For more information: www.honeywell.com/security/hsc Automation and Control Solutions Honeywell Security & Commuiications 2 Corporate Center Dr. Suite 100 Melville, NY 11747 1.800.467.5875 www.honeywell.com L1/FtEXBR/D Febry 2011 © 201. Honeywell ntemaioaI CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM . LISTING SERVICE LISTING No. 7300-1645:0127 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: HONEYWELL SECURITY2 Corporate Center Dr, Ste. 100, Melville, NY 11747 Contact: Issa Khouryawad (516) 577-2312 Fax (516) 577-3540 Email: issa.khouryawad@honeywell.com DESIGN: Models 41935N, *4193 SNP zone expander modules and 4190SN 2-Zone Expansion Module.The modules are accessories for use with Ademco fire alarm control panels supporting polling loop devices. They are intended to be connected to the control unit's polling circuitry and provide point identification for devices which are provided only with a set of dry contacts. Models must be installed within the control panel cabinet or inside a UL listed enclosure. For fire alarm, the supervised zone must be used. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 8-12VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use only with Ademco's separately listed fire alarm control units. NOTE: Formerly 7300-0078:178 *Rev 12-27-12 gt ' This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 Listing Expires June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division