Loading...
HomeMy WebLinkAbout2910 JEFFERSON ST; ; AS160224; PermitCity of Carlsbad Sprinkler Permit Permit No: AS160224 2910 JEFFERSON Job Address: ST Permit Type: SPRINK Parcel No: 2033541300 Lot #: 0 Reference No.: PC #: Status: ISSUED Applied 8/2/2016 Approved: 8/2/2016 Issued: 8/2/2016 Inspector: Project Title: 2910 JEFFERSON BACKFLOW DEMO EXISTING SINGLE DETECTOR CHECK VALVE & INSTALL NEW 4" WLKINS 375ADA (RPDA) BACKFLOW PREVENTOR. RELOCATED EXISTING FDC & WAFER CHECK VALVE. Applicant: COSCO FIRE PROTECTION 4990 GREEN CRAIG LN SAN DIEGO, CA 858-444-2000 Owner: BESAW FAMILY TRUST 10-21-01 34382 STARBOARD LANTERN DANA POINT CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 445 0 445 0 San Diego Branch Office cosco 4990 Greencraig Lane ,. San Diego, CA 92123 I s...... 4-2000 fax: 444-2056 Fire Protection (858) 44 CA Lic.: C-16 #577621 www.coscoflre.com MATERIAL SUBMITTAL & HYDRAULIC CALCULATIONS Date: 6-27-16 2910 JEFFERSON BACKFLOW 2910 JEFFERSON STREET CARLSBAD, CA. 92008 JOB # 10.CD 5690 All material submitted, may be substituted by material of equal performance & design, & shall be deemed acceptable by purchaser. AS 1 60224 Submitted by: HUGO A. 2910 JEFFERSON ST Los Angeles 0 San Francisco 0 Orange 0 Fresno 0 San Diego 0 Seattle U ZURN Model 375ADA WILKINS Reduced Pressure Detector Assembly 0 Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. The Model 375ADA shall provide protection where a potential health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance ASSE® Listed 1047 (2 1/2 - 8') CSA® Certified B64.4 (2-1/2 - 8) AWWA Compliant C550 UL® Classified C-UL® Classified FM® Approved Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California. NYC MEA 104-05-M NSF® Listed-Standard 61, Annex G* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backflow Assembly 3/4" Model 975XLD Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM, NSF Listed Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM, NSF Listed Sensing line Stainless steel, braided hose Features Sizes: 2 1I2*, 3* 4", 6", 8", 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 *2 1/2" & 3" sizes use 4' body & reducer coupling Dimensions & Weights (do not include pkg.) WILKINS Options (with OS&Y gates) (Suffixes can be combined) El - with OS & Y gate valves (standard) E] L - less shut-off valves (grooved body con- nections) LM - less water meter - with remote reading meter - with gallon meter (standard) - with cu ft/min meter G - with groove end gate valves El FG - with flanged inlet gate connection and grooved outlet gate connection MS - with Integral Relief Valve Monitor Switch BG - with grooved end butterfly valves with integral supervisory switches El BF - with flanged end butterfly valves with integral supervisory switches L P1 - with Post Indicator Gate Valve Accessories 0 Air gap (Model AG) Repair kit (rubber only) E] Thermal expansion tank (Model XT) fl OS & Y Gate valve tamper switch (OSY-40) El QT-SET Quick Test Fitting Set MODEL 375ADA with standard OS&Y WEIGHT MODEL WITHOUT WITH WITH 375ADA GATES WITH OS&Y WITH OS&Y BUTTERFLY BUTTERFLY SIZE GATES (GXF) GATES (GXG) VALVES VALVES (GXG) (GXF) in. Immlbs s jths ths Ibsj 21/2 65 112 50.8 214 97 206 93.5 154 70 164 74 380 111 50 23110&8 221 1003 156 7116977 41009845 252 114226 103 1 146 66 68 76 6 ThU Thi 69 387 176 357 162 225 102 255 116 200321 146 797 362 773 351 465 . 211 511 232 MODEL 375ADA With BG option Attention: Model 375ADA (grooved body) and Model 375DA (flange body) have different lay lengths. MODEL 1 375ADA I I A WITH SIZE I A I BUTTERFL' VALVES in. I mm I in. I mm I in. I mm DIMENSION (apero BLESS I I I l 6 I EWITH I GATE I c I c IoS&YEoPENI OS&Y I BUTTERFLY I VALVES I I I CLOSED I VALVES I In. I mm I In. I mm I in. I mm I In. I mm I in. I mm I in. Imm I in. Zurn Industries, LLC I Wilkins 1747 commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876 Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. E Date: 10/15 Document No. BF-375ADA Patent No. 5,913,331 Product No. Model 375ADA Page 1 of 2 C O Rated Flow (established by approval agencies) 31.5 to 104 CL 69 uj 35 Soo 101.0 104 a 150MM V) 35 0 400 800 1200 1600 FLOW RATES (GPM) MODEL 375ADA 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 252.4 - - Flow Characteristics MODEL 375ADA2-112" -3" (STANDARD AND METRIC) 0 6.3 12.6 FLOW RATES (us) 18.9 25.2 19 15 a. ; 1: IL 0 100 200 FLOW RATES (GPM) 300 400 MODEL 375ADA4" & 6" (STANDARD & METRIC) FLOW RATES (Us) - 0.0 25.2 50.5 75.7 C i o a 104 0 -J 69 uj 35 co A OL 4000 U, U, a. 0 1000 2000 3000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instruc- tions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12' (305mm) and a maximum of 30' (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 1 2644 1 3525 5288 p.=. •% ..IwI.:.. l.JI .4 FIX $ aIIfr:UØ2iII DIRECTION OF FLOW C) DIRECTON OF FLOW 4) OUTDOOR INSTALLATION (MODEL 375ADA with BG option) INDOOR INSTALLATION (MODEL 375ADA with G option) Specifications The Reduced Pressure Detector Backflow Prevention Assembly shall be ASSE® Listed 1047, and supplied with full port OS & V gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Backflow Prevention Assembly shall be a WILKINS Model 375ADA. Zum Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 11_2 Ph. 905-405-8272, Fax 905405-1292 www.zurn.com Page 2 of 2 OSYSU Series Outside Screw an4 Yoke Vqlv go.POTTER The Symbol of Protection Supervisory Swztca Features NEMA 4X* (IP 65) and 6P (IP 67) *Enclosure is 4X For additional corrosion protection of mounting hardware, use model OSYSU-2 CR1-I -40° to 1400 (-40°C to 60°C) operating temperature range Visual switch indicators Two conduit entrances Adjustable length trip rod Accomodates up to I2AWG wire Three position switch detects tampering and valve closure Knurled mounting bracket prevents slipping Fine adjustment feature for fast, easy installation RoHS compliant One or two SPDT contact models (-1,-2) I Before any work is done on the fire sprinkler or fire alarm system, the I SIGNALING I building owner or their authorized representative shall be notified. I I Before opening any closed valve, ensure that opening the valve will not C®US ( E cause any damage from water flow due to open or missing sprinklers, I LISTED + APPROVED piping, etc. I .Important: This document contains important information on the installation and operation of OS&Y valve supervisory switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description The OSYSU is used to monitor the open position of an OS&Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS&Y valves ranging in size from 2" to 12" (50mm to 300mm). They will mount on some valves as small as '/2" (12,5mm). The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device. Testing The operation of the OSYSU and its associated protective monitoring system shall be inspected, tested, and maintained in accordance with all applicable local and national codes and standards and/or the Authority Having Jurisdiction (manufacturer recommends quarterly or more frequently). A minimum test shall consist of turning the valve wheel towards the closed position. The OSYSU shall operate within the first two revolutions of the wheel. Fully close the valve and ensure that the OSYSU does not restore. Fully open the valve and ensure that the OSYSU restores to normal only when the valve is fully opened. A CAUT1014 Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Technical Specifications Dimensions See Fig 8 Weight 1.6 lbs (0,73 kg) Cover: Die Cast Finish: Red Powder Coat Enclosure Base: Die Cast Finish: Black Powder Coat All parts have corrosion resistant finishes Tamper Resistant Screws Cover Tamper Optional Cover Tamper Switch Available OSYSU-l: One Set of SPDT (Form C) OSYSU-2: Two Sets of SPDT (Form C) Contact Ratings 10.0 Amps at 125/250 VAC 2.0 Amps at 30VDC Resistive 10 mAmps minimum at 24 VDC -40° F to 140°F (-40°C to 60°C) Environmental NEMA 4X (IP 65) and NEMA 6P (IP 67) Enclosure Limitations (Use suitably rated conduit and connector) Indoor or Outdoor Use (See OSYSU-EX Bulletin 5400705 for Hazardous locations) Conduit Two Knockouts for 1/2" conduit provided Entrances (See Notice on Page 6 and Fig. 9 on Page 5) Service Use NFPA 13,13D, 13R, 72 Specifications subject to change without notice Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 10F6 I OSYSU Series POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Swztcn Theory of Operation The OSYSU is a 3 position switch. The center position is the normal installation position. Normal is when the switch is installed on the OS&Y valve, the valve is fully open and the trip rod of the OSYSU is in the groove of the valve stem. Closing the valve causes the trip rod to ride up out of the groove and activates the switches. Removing the OSYSU from the valve causes the spring to pull the trip rod in the other direction and activates the switches. Visual Switch Status Indication There are 3 visual indicators to determine the status of the switches. Fig I; the actuator button of the micro switches are on the raised section of the switch actuator. Fig 2; the trip rod is perpendicular to the base and lined up with the alignment mark on the mounting bracket. Fig 3; the white visual indicator is visible through the window on the back of the switch actuator. A final test is to meter the contacts marked COM and N.O. to ensure they are an open circuit when the valve is open and that they close and have continuity within 2 revolutions of turning the valve handwheel towards the closed position and the contacts remain closed as the valve is completely closed and until the valve is completely opened when the trip rod drops back into the groove in the valve stem. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 2OF6 OSYSU Series (P) POTTER Outside Screw and Yoke Valve The Symbol of Protection Supervisory Switch Small Valve Installation - 1/2" Through 2 1/2" Sizes Fig uu Slotted mounting holes and micro-adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Small Valve Installation NOTE: If the valve stem is pre-grooved at 1/8" minimum depth; proceed to step 7. . 1. Remove and discard "E" ring and roller from the trip rod. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland so that the spring loaded trip rod of the OSYSU is pulled against the non threaded portion of the valve stem. Position the OSYSU with the bracket near the handwheel as shown in Fig. 6 if possible to avoid creating a pinch point between the wheel and the OSYSU. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 5). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to 5 in-lbs minimum to hold the trip rod in place and properly seal the enclosure. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 10). Reinstall trip rod and repeat Step 3 procedure. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. Mark the valve stem at the center of the trip rod. Remove the OSYSU. Utilizing a 3/16" or 1/4" diameter straight file, file a 1/8" minimum depth groove centered on the mark on the valve stem. Deburr and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. NOTE: A groove depth of up to approximately 3/16" can make it easier to install the OSYSU so that it does not restore as it rolls over by the threads of the valve stem. Mount the OSYSU on the valve yoke with the spring loaded trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the OSYSU with the flat side of the bracket toward the hand wheel, as shown in Fig. 6, to help avoid creating a pinch point between the wheel and OSYSU. When in this preferred mounting position, it is usually best to use the white indicator visible through the window, as illustrated in Fig. 3, to aid in initially locating the OSYSU in the correct position on the yoke. If the unit must be installed inverted with the white indicator no longer easily visible, use the visual indicators of the actuator buttons on the micro-switches, as illustrated in Fig. 1, or the trip rod alignment mark on the bracket, as illustrated in Fig. 2 , to aid in initially locating the OSYSU. Final adjustment can be made by slightly loosening the two screws on the bracket and using the fine adjustment feature (see Fig. 5). The adjustment is correct when the plungers on the switches are depressed by the actuator and there is no continuity between the COM and NO terminals on the switches. Tighten the adjustment screws and all mounting hardware securely (20 in-lbs minimum). Check to insure that the rod moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL OPEN towards the CLOSED position. Reinstall the cover and tighten the cover screws to 15 in-lbs minimum to properly seal the enclosure. A CAUTION Close the valve fully to determine that the stem threads do not activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525. REV E • 8/15 PAGE 3OF6 OSYSU Series POTTER Outside Screw and Yoke Vqlvç The Symbol of Protection Supervisory Switch Fig 7 Large Valve Installation - 3" Through 12" Sizes Slotted mounting holes and micro- adjustment feature may be used for fine adjustment of switch assembly to mounting bracket. Re-tighten screws to 20 in-lbs minimum. Large Valve Installation as it rolls over by the threads of the valve stem. NOTE: If the valve stem is pre-grooved at 1/8" minimum 6. Mount the OSYSU on the valve yoke with the spring loaded depth; proceed to step 6. trip rod of the OSYSU pulled against the valve stem and centered in the groove of the stem. If possible, position the With the valve in the FULL OPEN position, locate the OSYSU with the flat side of the bracket toward the hand OSYSU across the valve yoke as far from the valve gland wheel, as shown in Fig. 7, to help avoid creating a pinch as possible so that the spring loaded trip rod of the OSYSU point between the wheel and OSYSU. When in this preferred is pulled against the non threaded portion of the valve stem, mounting position, it is usually best to use the white indicator Position the OSYSU with the bracket near the handwheel as visible through the window, as illustrated in Fig. 3, to aid in shown in Fig. 7 if possible to avoid creating a pinch point initially locating the OSYSU in the correct position on the between the wheel and the OSYSU. yoke. If the unit must be installed inverted with the white Mount the OSYSU loosely with the carriage bolts and clamp indicator no longer easily visible, use the visual indicators bar supplied, of the actuator buttons on the micro-switches, as illustrated Loosen the locking screw that holds the trip rod in place and in Fig. 1, or the trip rod alignment mark on the bracket, as adjust the rod length (see Fig. 5). When adjusted properly, illustrated in Fig. 2 , to aid in initially locating the OSYSU. the rod should extend past the valve screw, but not so far 7. Final adjustment can be made by slightly loosening the two that it contacts the clamp bar. Tighten the locking screw to screws on the bracket and using the fine adjustment feature 5 in-lbs minimum to hold the trip rod in place and properly (see Fig. 5). The adjustment is correct when the plungers seal the enclosure, on the switches are depressed by the actuator and there is NOTE: If trip rod length is excessive, loosen the locking no continuity between the COM and NO terminals on the screw and remove the trip rod from the trip lever. Using switches. pliers, break off the one (1) inch long notched section (see & Tighten the adjustment screws and mounting hardware Fig. 10). Reinstall trip rod and repeat Step 3 procedure. securely (minimum 20 in-Ibs). Check to insure that the rod Mark the valve stem at the center of the trip rod, moves out of the groove easily and that the switches activate within two turns when the valve is operated from the FULL Remove the OSYSU. Utilizing a 3/8" or '/2" diameter straight OPEN towards the CLOSED position. file, file a 1/8" minimum depth groove centered on the mark 9. Reinstall the cover and tighten the cover screws to 15 in-lbs on the valve stem. Deburr and smooth the edges of the minimum to properly seal the enclosure. groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the I A CAUTION valve is operated. I I I NOTE: A groove depth of up to approximately 3/16" can Close the valve fully to determine that the stem threads do not I make it easier to install the OSYSU so that it does not restore I activate the switch. The switch being activated by the stem threads could result in afalse valve open indication. Potter Electric Signal Company, LLC • St. Louis, MO • Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 5401525- REV E • 8/15 PAGE 4OF6 Nj EM Rod retracted and (2672) breakaway section removed [93.26 Rod fully extended Cover Tamper Switch (2)o.886 Knockouts For I/ Electrical Conduit Connections Ground S )/4"-20] Hardwar Clamp Bar ved 9.09 (77.47 2.23 157 113 0 rP) POTTER The Symbol of Protection OSYSU Series Outside Screw and Yoke Vqlvç Supervisory Switch Dimensions Fig 8 Knockout Removal Fig 9 To remove knockouts: Place screwdriver at inside edge of knockouts, not in the center. NOTE: Do not drill into the base as this creates metal shavings which can create electrical hazards and damage the device. Drilling voids the warranty. Potter Electric Signal Company, LLC • St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com 540)525- REV E • 8/15 PAGES OF 6 rP') POTTER 10 The Symbol of Protection Breaking Excessive Rod Length Fig 10 mm~ Switch Terminal Connections Clamping Plate Terminal Fig 11 All conduit and connectors selected for the installation of this product shall be suitable for the environment for which it is to be used and shall be installed to the manufacturer's installation instructions. For NEMA 4, 4X, 6, 6P installations, the cover screws are recommended to be tightened to 15 in- lbs minimum and the trip rod locking screw tightened to 5 in-lbs minimum to properly seal the enclosure. Typical Electrical Connections Fig 12 EOLR CM NC N NO NCCOM TO FIRE ALARM PANEL S An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be .severed, thereby providing supervision of the connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device inoperable risking severe property damage and loss of life. Do not strip wire beyond 3/8" of length or expose an uninsulated conductor beyond the edge of the terminal block. When using stranded wire, capture all strands under the clamping plate. OSYSU Series Outside Screw and Yoke Vqlvç Supervisory Switch Ordering Information Model Description Stock No. OSYSU-1 Outside Screw & Yoke 1010102 Supervisory Switch (Single switch) OSYSU-2 Outside Screw & Yoke 1010202 Supervisory Switch (Double switch) OSYSU-2 Outside Screw & Yoke Supervisory 1010210 CRH Switch (Double Switch). Corrosion resistant hardware of 316 stainless steel & nickel plated to ASTM B377 Type V Brackets Cover Screw 5490424 Hex Key for Cover Screws and 5250062 Installation Adjustments Optional Cover Tamper Switch Kit 0090200 Engineering Specifications: OS&Y Valves UL, CUL Listed / FM Approved and CE Marked valve supervisory switches shall be furnished and installed on all OS&Y type valves that can be used to shut off the flow of water to any portion of the fire sprinkler system, where indicated on the drawings and plans and as required by applicable local and national codes and standards. The supervisory switch shall be NEMA 4X and 6P rated and capable of being mounted in any position indoors or out and be completely submerged without allowing water to enter the enclosure.. The enclosure shall be held captive by tamper resistant screws. The device shall contain two 1/2 conduit entrances and one or two Single Pole Double Throw (SPDT) switches. There shall be a visual indicator to display the status of the switches. To aid in installation, it shall be possible to make fine adjustments to the position of the switch on the valve without loosening the mounting bracket from the valve. The device shall contain an adjustable length trip rod and roller, the trip rod shall be held captive by a set screw accessible upon removal of the cover. The switch contacts shall be rated at I OA, 125/250VAC and 2A, 30VDC. OS&Y Valve supervisory switch shall be model OSYSU-1 for the single switch model and OSYSU-2 for the two switch model manufactured by Potter Electric Signal Company LLC Es) I [I Supervisory switches have a normal service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. Potter Electric Signal Company, LLC St. Louis, MO Tech Support: 866-956-0988 / Customer Service: 866-572-3005 • www.pottersignal.com ISO 9001:2008 1 DESIGNING, MANUFACTURING, WI I $11 & DISTRIBUTING QUALITY SYSTEMS 5401525 - REV £ • 8/15 PAGE 6 OF 6 QL4 Municipal Water District APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES Please submit a completed Approved Materials List to the District's Share File site (all 11 pages). The Project Name should be listed at the top of each page. To obtain a link to the Share File site please contact the Engineering Department Assistant. PROJECT NAME: Supplier Name: (W F2- Contact Person: /xc. A-&1o, Ur- Phone: (i) 2LC-7 ._9f571 - FOR DISTRICT USE ONLY BELOW THIS LINE REVIEWED ONLY FOR GENERAL CONFORMITY TO PLANS AND STANDARD SPECIFICATIONS U APPROVED PROJECT #: U APPROVED AS NOTED U MAKE CORRECTIONS NOTED & RESUBMIT U REJECTED EAM WO#: Initials Date As-Built Stamp: ,fl CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: 2910 Jefferson St. SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2910 Jefferson St. CITY: Carlsbad PHONE: (_858 ) 444-2000 x 1715 (Cosco Fire Protection, Inc.) FAX NUMBER: (858) 444-2056 Largest Building (ft.2): Sprinkled? __ Construction Type:__________________ SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): southeast corner of Grand and Jefferson TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 86 PSI Hydrant Number (if applicable): H62262 Elevation of test 56 Feet Date/Time of Test1 Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 6,375 GPM Residual Pressure 20 PSI At peak demand. this water system is capable of providing a fire flow discharge @ 20 psi of 6,375 gpm. This flow does not exceed the maximum 15 fps criteria for the City. 'Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x I have witnessed and/or reviewed this water flow information and by personal knowledge and/or on-site observation certify that the above information is correct. Name: Jennifer R.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: 7)1/ Tit?e/Org: PiectManager Date: 06/30/2016 . . 2910 Jefferson St Fire Flow Availability Prepared By: Jennifer R. Mae[, P.E. - MCS Date: Thursday, June 30, 2016 0 Fire Protection by Computer Design COSCO FIRE PROTECTION 4990 Greencraig Lane San Diego, CA. 92123 (858) 444-2000 Job Name : JEFFERSON BACKFLOW PROOF CALC Building : FP1 Location 2910 Jefferson Street Carlsbad, CA. 92008 System : EXISTING Contract 10.CD_5690 Data File PROOF CALC.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I COSCO FIRE PROTECTION JEFFERSON BACKFLOW PROOF CALC 16 HYDRAULIC CALCULATIONS for Project name: Jefferson Backflow Location: 2910 Jefferson Street Carlsbad, CA. 92008 Drawing no: FP1 Date: 6-30-16 Design Remote area number: EXISTING Remote area location: EXISTING BLDG Occupancy classification: N/A Density: .068 - Gpm/SqFt Area of application: 3000 - Sq Ft Coverage per sprinkler: N/A - Sq Ft Type of sprinklers calculated: N/A No. of sprinklers calculated: EXIS ITNG In-rack demand: N/A - GPM Hose streams: 500 - GPM Total water required (including hose streams): -GPM Type of system: WET Volume of dry or preaction system: N/A - Gal Water supply information Date: 6-30-16 Location: JOB SITE . Source: STATIC: 86 PSI, RES.:20 PSI, FLOW: 6375 GPM Name of contractor: COSCO FIRE PROTECTION Address: 4990 GREENCRAIG LANE SAN DIEGO, CA. 92123 Phone number: (858) 444-2000 Name of designer: H.A. Authority having jurisdiction: CARSLBAD FIRE DEPARTMENT Notes: (Include peaking information or gridded systems here.) Page 1 Date 6-30-16 @ -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Sup .urve C COSCO FIRE P OTECTION JEFFERSON BACKFLOW PROOF CALC S Page 2 Date 6-30-16 City Water Supply: Demand: Cl - Static Pressure : 86 Dl - Elevation : 0.217 C2 - Residual Pressure: 20 D2 - System Flow : 232.9 C2 - Residual Flow : 6375 . D2 - System Pressure : 68.001 Hose ( Demand) : 500 D3 - System Demand : 732.9 Safety Margin : 16.792 150 140 130 p120 110 R E10° 590 : 580 U 70 60 - R 13 E5° 40 30 20 C2 10 .... .... . 75911500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings USummary COSCO FIRE OTECTION Page 3 JEFFERSON BACKFLOW PROOF CALC Date 6-30-16 Fitting Legend Abbrev. Name 1/2 % 1 1% 1'/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I NFPA139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD COSCO FIRE PROTECTION Page 4 JEFFERSON BACKFLOW PROOF CALC Date 6-30-16 Node Elevation K-Fact Pt Pn Flow Density Area Press o. Actual Actual Req. BOR 0.5 64.9 na 232.9 UG1 -3.0 66.62 na BF1 -3.0 67.51 na BF2 -3.0 68.36 na TEST 0.0 68.0 na 500.0 The maximum velocity is 5.66 and it occurs in the pipe between nodes BOR and UG1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams - 2007 cosco FIRE PROTECTION Page 5 JEFFERSON BACKFLOW PROOF CALC Date 6-30-16 .Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt P1/Ft Eqv. Ln. Total P1 Pn *UG PIPING BOR 232.90 4.1 E 14.534 2.750 64.900 Qa = 232.90 to 140.0 - 0.0 14.534 1.516 UG1 232.9 0.0120 0.0 17.284 0.208 Vel = 5.66 UG1 0.0 4.1 3E 43.601 30.500 66.624 to 140.0 0.0 43.601 0.0 BF1 232.9 0.0120 0.0 74.101 0.890 Vel = 5.66 BFI 0.0 4.1 T 29.067 12.000 67.514 to 140.0 2E 29.067 58.134 0.0 BF2 232.9 0.0120 0.0 70.134 0.843 Vel = 5.66 BF2 0.0 4.1 E 14.534 32.000 68.357 to 140.0 G 2.907 46.508 -1.299 TEST 232.9 0.0120 1 29.067 78.508 0.943 Vel = 5.66 500.00 Qa = 500.00 732.90 68.001 K Factor= 88.88 C S Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Oil VENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, 0 RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section AIR/VACUUM VALVE 2 Piece Assembly with Bolt Down Base and 15092 VCAS-1424-SM w/tape & screen ENCLOSURE Removable Cover, Polyethylene Material, Sandstone VCAS-1830-SM w/tape & screen *must be accompanied by Color with Identification Band, OSHA Blue for VCAS-2436-SM w/tape & screen - a shop drawing WATER, OSHA Purple for Recycled Water 1424 for 1" r Potable 1830 for 2" 2436 for 3" r RCW ANGLE METER STOP, 1" Bronze Angle Meter Stop (Ball Valve) with 90 15081 Ford BA43-444W-Q-NL QUICK JOINT X Degree Lockwing, Inlet Quick Joint for Copper Jones - J1963WSG METER NUT Water Tube x Meter Swivel Nut Outlet McDonald 74602BQ Mueller - B24258 ANGLE METER STOP, 1-1/2", 2" Bronze Angle Meter Stop (Ball Valve) 15081 Ford BFA43-777W-Q-NL QUICK JOINT X with 90 Degree Lockwing, Inlet Quick Joint for Jones - J1975WSG - METER FLANGE Copper Water Tube x Meter Flange Outlet McDonald 74602BQ - Mueller - B24276 ANGLE VALVE Bronze Angle Valve, 2" and Smaller 15080 Nibco T-375-B - 300 PSI Rated, Female Threaded Ends Jones J-380 - ANGLE VALVE Bronze, Angle Design, 300 PSI Rated, 4" Inlet 15080 Jones J-344HP - HYDRANT HEAD Female IPT, 2-1/2" Outlet National Standard Hose Thread, Cap and Chain ANODE, MAGNESIUM High or Standard Potential Anode with a Galvanized 13110 Corrpro - *n:ust be accompanied by Steel Core Encased in a Square Magnesium Alloy Corrosion Control Products - a shop drawing Ingot Pre-Packaged in a Permeable Cotton Cloth Farwest Bag. Provide Ingot Weight as Specified on the Calpico Approved Plans ANODE, ZINC Each Zinc Anode shall be Pre-Packaged in a 13110 Corrpro - Permeable Cloth Bag and shall Weigh 30 Pounds Corrosion Control Products - Farwest Calpico Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 2 Revised 08/19/14 0 OLIVENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, 10 RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project f?g& i3Fe) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section BACKFLOW Reduced Pressure Principal Type Assemblies as 15112 List of Approved Backflow PREVENTER Approved by the State of California, Department of Prevention Assemblies *n,ust be accompanied by Health Services - a shop drawing BOLT KIT, 316 SS Hex-Head Machine, ASTM A193, Grade B 8M 15050 Tripac Fasteners - *for specific uses only Bolts and ASTM A 194, Grade 8M Nuts, Grade 8M Pacific Coast Bolt - Flat Washers ITP, Inc. - Bolt Kit includes: Bolts, Nuts, and Flat Washers BOLT KIT Hex-Head Machine, Cadmium/Zinc Plated, ASTM 15050 Tripac Fasteners - A307, Grade B Bolts and A307 2H Heavy Hex Nuts Pacific Coast Bolt Bolt Kit includes: Bolts, Nuts, and Flat Washers ITP, Inc. BURY ELBOW, 16' DI Long Radius Bury El, MJ or P0 15109 Clow - DUCTILE IRON Holiday Free Epoxy Lined Bells Star Sigma - South Bay Foundry CATHODIC TEST 54 Lb Concrete Body with 12 Lb Ductile Iron Lid 13110 Brooks 1 -RT - STATION BOX and Lid Ring. "CP TEST" shall be Cast into the Lid Farwest Type 1-RT - in 1" Letters. For Cathodic Protection Test Stations, J&R 3RT - Anode Ground Beds and Insulated Flange Test Stations CATHODIC WELDING For Welding Cathodic Bond Wires to Steel Pipelines 13110 Cadweld - COATING, INTERNAL For Coating the Internal Pipe Lining for an Insulated 13110 Aquatapoxy CCI - PIPE Flange Kit Hydro-Pox - CONNECTOR, All Brass Split Bolt to be Accompanied and Encased 15292 TRACER WIRE with Rubberized Tape, and then Electrical Tape 15293 SPLICING KIT Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 3 Revised 08/19/14 0 OLIVENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, 0 RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project e4y22,c ek) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section CORPORATION STOP, Bronze Ball Valve, Male Iron Pipe Thread x Quick 15080 Ford FB 1100-x-Q-NL - MIPT X QUICK JOINT Joint (T-Head Only), 1", 1-1/2" and 2" Full MCD 74704BQ - Opening Mueller - B25028 - 1" 1-1/2" 2" Jones - J1935 SG 0 0 COUPLING, C900 PVC, 4" through 12" Solid PVC for Obtaining Deflection 15292 CertainTeed - HIGH DEFLECTION Only. Provides 4 Degree Maximum Deflection 4" 6" 8" 10" 12" 30000 COUPLING, C900 PVC, 4" through 12" Solid PVC for Closure or Repair 15292 CertainTeed - CLOSURE / REPAIR 4" 6" 8" 10" 12" ]000 COUPLING, C905 PVC, 4" through 12" Solid PVC for Obtaining Deflection 15293 Specified HIGH DEFLECTION Only. Provides 4 Degree Maximum Deflection 14" 16" 18" 20" 24" 30000 COUPLING, Use for Above Ground DI or Steel Pipe 15061 Grinnell #7001 - MECHANICAL 4" or Larger 15240 Tyler 500 - CLAMP-TYPE 15251 Victaulic #44, #77 - *must be accompanied by a shop drawing COUPLING, 4" and Larger, Steel or Ductile Iron Construction, 15122 APAC 301 STRAIGHT Slip x Slip, Epoxy Coated with 304 or 316 Stainless Ford FC1 - FLEXIBLE Steel Bolts and Nuts. Powerseal 3501 - *n,usf be accompanied by For Use on AC, PVC, DI, or Steel Pipe Romac 501 - a shop drawing Must be Restrained When Used with AC Pipe Smith-Blair 411 - Indicate Size Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 4 Revised 08/19/14 C n 61 C OLIVENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project 4t L) tk-) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section COUPLING, 4" and Larger, Steel or Ductile Iron Construction, 15122 APAC 311, 313 TRANSITION Holiday Free Epoxy Coated with 304 or 316 SS Ford FC2A - FLEXIBLE Bolts and Nuts. Powerseal 3501, 3506 - *n,ust be accompanied by For use on AC, PVC, DI, or Steel Pipe. Romac XR501 - a shop drawing Must be Restrained When Used with AC Pipe Smith-Blair 413 - Indicate Size DISMANTLING JOINT Telescoping, Adjustable, Double Flanged Fitting, Romac Flexijoint - *must be accompanied by with High Tensile Strength Zinc Plated Tie Bars. Star - StarFiex a shop drawing NSF-61 Epoxy or Nylon Interior and Exterior Coating FIRE HYDRANT, Cast Iron 12" through 18" Long with Machined 15109 South Bay Foundry BREAK-OFF RISERS V-Groove 4" from One End, Groove to be 1/8" to 15090 Clow 3/16" Deep and ¼" Wide Sigma - Star FIRE HYDRANT 6" High Pressure 200 PSI Wet Barrel, Bronze Fire 15109 Clow 2060, 2065 - Up To 200 PSI Hydrant, with Six-Hole Bolt Pattern Jones J3765, J3775 - American AVK 2464X, 2468X - FITTING, DUCTILE Flanged, Push On, Tees, Bends, Crosses, Reducers, 15240 Bachman - IRON, 4" Adapters, etc. For 4", Per AWWA Cl 10, C1 11, 15292 Sigma C153 and OMWD Standards. Holiday Free Epoxy 15293 Star - Lined Bells Tyler 111/4 22 1/2 45 90 Tee End Cap US Pipe 0 00 00 FITTING, DUCTILE Flanged, Push On, Tees, Bends, Crosses, Reducers, 15240 Bachman - IRON, 6" Adapters, etc. For 6", Per AWWA Ci 10, C1 11, 15292 Sigma - C1 53 and OM\VD Standards. Holiday Free Epoxy 15293 Star Lined Bells Tyler - 111/4 221/2 45 90 Tee End Cap US Pipe 0 0000 - Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 5 Revised 08/19/14 Oil VENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project 1F7Q'( 73'jfti) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section FITTING, DUCTILE Flanged, Push On, Tees, Bends, Crosses, Reducers, 15240 Bachman IRON, 8" Adapters, etc. For 8", Per AWWA C1 10, C1 11, 15292 Sigma C153 and OMWD Standards. Holiday Free Epoxy 15293 Star Lined Bells Tyler - 111/4 22 1/2 45 90 Tee End Cap US Pipe O 00000 FITTING, DUCTILE Flanged, Push On, Tees, Bends, Crosses, Reducers, 15240 Bachman IRON, 10" Adapters, etc. For 10", Per AWWA Ci 10, Ci 11, 15292 Sigma C153 and OMWD Standards. Holiday Free Epoxy 15293 Star - Lined Bells Tyler 11-1/4 22-1/2 45 90 Tee End Cap US Pipe o 0 000 0 FITTING, DUCTILE Flanged, Push On, Tees, Bends, Crosses, Reducers, 15240 Bachman - IRON, 12" Adapters, etc. For 12", Per AWWA C 10, Ciii, 15292 Sigma C15 3 and OMWD Standards. Holiday Free Epoxy 15293 Star Lined Bells Tyler 11-1/4 22-1/2 45 90 Tee End Cap US Pipe 0 0 DO DO FLANGE COUPLING 6" and Larger, Mechanical x Flange. Steel or Ductile 15.122 Dresser 127, 128 - ADAPTER Iron without Anchor Pins, Holiday Free Epoxy Ford FFCA Style Coated, 304 SS Bolts and Nuts. Baker 601, 602 Powerseal 3521, 3526 Romac FCA501, FC400 Smith-Blair 912, 913 GASKET, PAPER 1/8" Thick Full Face or Ring, Aramid Fiber Bound 15050 Garlock Bluegard - with Nitrile. No Asbestos Content Klinger C4400 - Full Face Tripac 5000 X. 0 Calpico - S Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 6 Revised 08/19/14 I—] Oil VENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project 1rr))v PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section GROUT Non-Shrink Cement Based Construction Grout for 03000 UPCON High Flow - Crack Repair, Flooring Mortar, Dowel Grouting, Master Flow 713 - Crack Sealing and General Binding INSULATING BLANKET Insulating Blanket for Corrosion Interference 13110 *must be accompanied by Mitigation a shop drawing INSULATING Insulating Couplings for Corrosion Protection of 15080 Wilkins Model DUXL - COUPLINGS Pipelines/Appurtenances Watts Model LF3 003 *must be accompanied by 1" 1 1/2" 2" 3" a shop drawing 0 0 0 0 INSULATING FLANGE Insulating Flange Kits for Corrosion Protection of 13110 Advance Product Systems KIT Pipelines/Appurtenances Calpico Corrpro Farwest JOINT RESTRAINT 360 Degree Wedge Type Restraint System for 15240 Ford Uniflange 1300 Series - ASSEMBLY Ductile Iron and C900 PVC, Sizes 6" Through 24" 15292 Ford Uniflange 1500 Series EBAA Iron Sigma PV-LOK - Romac DI- Roma Grip Romac 600 Series MARKING TAPE 6" wide, Warning/Identification (Metallic) Marking 15061 Linetec - Tape for Buried Facilities 15240 Terra Tape - POT RCW S FM ELEC FIBER 15292 Calpico - 0 0 0 0 0 0 15293 Christy - S Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 7 Revised 08/19/14 S I Oil VENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Projecti 8TC/) Lk414l') PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section METER BOX 17"x28" Precast Meter Box and 2 Piece Polymer 15081 J&R Concrete Products, Inc. *must be accompanied by Concrete Cover with Reading Lid for 1" Water 15090 Armor Cast a shop drawing Service, Use Purple Covers for Recycled Water, 15091 Old Castle - For Water Service Installation, Polymer Concrete Cover Shall Have Hole for Touch Read Device. MAR and Blowoff Installation Does Not Require Hole Cut Out WS MAR/130 0 METER BOX 24"x36" Precast Meter Box and 2 Piece Polymer 15081 J&R Concrete Products, Inc. - *must be accompanied by Concrete Cover with Reading Lid for 1" Water Armor Cast a shop drawing Service, Use Purple Covers for Recycled Water Old Castle - For Water Service Installation, Polymer Concrete Cover Shall Have Hole for Touch Read Device MAR and Blowoff Installation Does Not Require Hole Cut Out WS MAR/130 0 OUTLET, WELD-ON Weld-On Outlet with Reinforcing Collar or Wrapper 15080 Pipeline Products *must be accompanied by for Connection to CML&C Steel Pipe a shop drawing PIPE, COPPER WATER Type K Soft Seamless Rolled Tubing, Type K Soft 15220 Cerro - TUBE Seamless Straight Lengths, Type K Hard Seamless Mueller - Straight Lengths (Soft - Buried Applicaton ONLY) Cambridge-Lee (Hard - Above Ground ONLY) Soft Hard 1" 1-1/2" 2" 3" 0 0 0 00 I Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 8 Revised 08/19/14 I OLIVENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications projectfr& PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section PIPE, DUCTILE IRON For Water Lines 4" and Larger Manufactured per 15240 American Pipe - *,,,ust be accompanied by AWWA C15 I Griffin - a shop drawing and lay Pacific States sheets U.S. Pipe PIPE, PVC C900 For Water Lines 4" through 12" Manufactured per 15292 Diamond Plastics - AWWA C900 in Class 150 and 200 Vinyllech - DR14 DR18 North American Pipe - 4" 6" 8" 10" 12" IM Eagle 00 D 0 PIPE, PVC C905 For Water Lines 14" through 24" Manufactured per 15293 Diamond Plastics AWWA C905 VinylTech - 14" 16" 18" 20" 24" North American Pipe 0 0 0 0 0 JMEagle PLASTIC 8-MTh Thick Polyethylene Encasement Tube for 09954 POLYETHYLENE Ductile Iron Pipe, CML&C. ENCASEMENT 109952 PLASTIC WRAPPER Clear Plastic Wrapper over Wax Tape Coating and Denso Tape PVC Self-Adhesive - Primer in Underground Applications Trenton Poly-Ply POLYETHYLENE 8-MIL Thick Polyethylene Encasement Sheet for 09954 WRAP Buried Fittings and Valves. Purple Color for Recycled Water SERVICE SADDLE Cast Bronze Body with Stainless Steel Double Band 15080 Ford - 202BS FOR ACP, DIP, AND Straps or Single Wide Strap with 4 Bolts, IF Outlet Romac - 202BS - PVC PRESSURE PIPE Sizes McDonald -3846 - ACP DIP PVC Jones - J-969 0 0 - 1" 1-1/2" 2" 0 0 Please Contact the District's Inspection Dept. for the material to be used lithe Part or Model numbers shown are no longer available. Pg 9 Revised 08/19/14 Oil VENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWDs Standard Specifications Project ftEl2't 42i) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section TAPE, PLASTIC 10 to 50 MIL x 2" Wide General Utility Tape for 09954 Calpico Vinyl Tape - ADHESIVE Corrosion Protection of Above and Below Ground 09952 Christy Pipes and Fittings Northtown - Polyken-900 - Scotchwrap - 50 - TAPPING SLEEVE Fabricated Stainless Steel Tapping Sleeve with 15080 Ford - FTSS - FOR ACP, DI, AND PVC Stainless Steel Bolts and Nuts PowerSeal - 3460AS PIPE Romac - SSTIII - Smith Blair - 665 - THREDOLET Forged Steel Fitting ASTM A105. 3000#, NPT 15061 Bonney Forge - Threads Allied Piping Products Pipeline Products TRACER WIRE AWG No. 8 Stranded Copper Wire with High 15292 Calpico - HMW/PE #8 - Molecular Weight Polyethylene (BMW/PE) 15293 Farwest - BMW/PE #8 - Insulation Specifically Designed for Direct Burial in KALAS - w-08hmwpe-str Corrosive Soil or Water VALVE BOX AND Cast Iron Frame and Lid and 12" Pipe Sleeve. Cast 15092 South Bay Foundry - SBF 1243 COVERS, on the Lid the Words "OMWD", and "WATER" or MANUAL AIR RELEASE "RW" AND BLOW-OFF (For Street Use Only) ASSEMBLIES *must be accompanied by a shop drawing VALVE BOX AND Cast Iron Frame and Cover and Extension Pipe. Cast 15101 South Bay Foundry - SBF 1208-N - COVERS, on the Cover the Words "OMWD", and "WATER" GATE VALVE or "RW" Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 10 Revised 08/19/14 n OLIVENHAIN MUNICIPAL WATER DISTRICT APPROVED MATERIALS LIST FOR CONSTRUCTION OF POTABLE WATER, RECYCLED WATER AND SEWER FACILITIES *All Material Being Used Shall Conform w/OMWD's Standard Specifications Project f1ZoA1 /Zc) PLEASE INDICATE WHICH PRODUCT YOU ARE USING BY PLACING AN "X" ON THE APPROPRIATE LINE TO THE RIGHT OF EACH MANUFACTURER Item Description Std Manufacturer Spec Section VALVE, Single Chamber, HDPE Control Floats, Stainless 15108 Vent-O-Mat DN25 RBX 2521 COMBINATION AIR Steel Body, 1/4" NPT Test/Bleed Cock Vent-O-Mat DN50 RBX 4021 - RELEASE & Vent-O-Mat DN80 RBX 1631 - AIR/VACUUM, 3" AND Vent-O-Mat DNIOO RBX 2531 - SMALLER VALVE, GATE, 3" through 24" Resilient Seated, Non-Rising Stem, 15101 AVK or Approved Equal - RESILIENT SEATED Counter-Clockwise Opening, Type 304 or 316 SS *must be accompanied by Body Bolts, 250 PSI Working Pressure, Holiday a shop drawing Free Interior Lining WAX TAPE COATING 4 Part, Cold Applied Wax Tape Coating System for 09952 Denso Densyl Tape Buried Piping Components Trenton No.1 Wax Tape - System Includes: Primer, Wax Tape, Clear Wrap, 10 MIL Tape, and 8 MIL Thick Polyethelene Sheet so Please Contact the District's Inspection Dept. for the material to be used if the Part or Model numbers shown are no longer available. Pg 11 Revised 08/19/14