HomeMy WebLinkAbout2830 CAZADERO DR; ; AS070301; PermitCity of Carlsbad
Sprinkler Permit
Permit No: AS070301
Job Address: 2830 CAZADERO DR
Permit Type: SPRINK
Parcel No: 2153204000
Lot #: 0
Reference No.:
PC #:
Status: ISSUED
Applied 12/27/2007
Approved: 12/27/2007
Issued: 12/27/2007
Inspector:
Project Title: ZEZELJ RESIDENCE THREE FIRE SPRINKLER INSPECTIONS
@ $65/EA
Applicant:
PREMIER FIRE PROTECTION
P0 BOX 2027
LAKESIDE, CA
619-871-9795
Owner:
ZEZELJ FAMILY TRUST 01-30-04
2807 LUCIERNAGA ST
CARLSBAD CA
Fees ($) Add'I Fees ($) Total ($) Balance ($)
tqco /Fire & Building
I Products
Technical Services: Tel: (800) 381-931?/ Fax: (800) 791-5500
,a
rapid response TI
HOME FIRE SPRINKLER SYSTEM
Series LFII Residential
Concealed Pendent Sprinklers, Flat Plate
49 K-factor
General
DescriptiOn
The Series LFIi (1Y3596) Residential
Concealed Pendent Sprinklers are decorative, fast response, fusible sol-
der sprinklers designed for use in resi-
dential occupancies such as homes,
apartments, dormitories, and hotels.
The cover plate assembly conceals
the sprinkler operating components
above the ceiling. The flat profile of the
cover plate provides the optimum aes-
thetically appealing sprinkler design.
In addition, the concealed design of
the Series IFil (TY3596) provides 1/2
inch (12,7 mm) vertical adjustment.
This adjustment reduces the accuracy
to which the fixed pipe drops to the
sprinklers must be cut to help assure
a perfect fit Installation.
The Series LFII are to be used in wet
pipe residential sprinkler systems for
one- and two-family dwellings and mo-
bile homes per NFPA 13D; wet pipe
residential sprinkler systems for resi-
dential occupancies up to and includ-
ing four stories in height per NFPA
13R: or, wet pipe sprinkler systems for
the residential portions of any occu-
pancy per NFPA 13.
The Series LFll (TY3596) has a 4.9
(60,5) K-factor that provides the re-
quired residential flow rates at reduced
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the"INSTALLER
WARNING that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and in-
stallation can permanently damage
a sprinkler system or Its compo-
nents and cause the sprinkler to fall
to operate in a fire situation orcause
it to operate prematurely.
Page 1 of 4
pressures, enabling smaller pipe sizes
and water supply requirements.
The Series LFlI (TY3596) has been
designed with heat sensitivity and
water distribution characteristics
proven to help In the control of residen-
tial fires and to improve the chance for
occupants to escape or be evacuated.
The Series LFIi (TY3596) Residential
Concealed Pendent Sprinklers are
shipped with a Disposable Protective
Cap. The Protective Cap is temporarily
removed for Installation, and then it
can be replaced to help protect the
sprinkler while the ceiling is being in-
stalled or finished. The tip of the Pro-
tective Cap can also be used to mark
the center of the ceiling hole into plas-
ter board, ceiling tiles, etc. by gently
pushing the ceiling product against the
Protective Cap. When the ceiling in-
stallation is complete the Protective
Cap is removed and the Cover Plate
Assembly installed.
WARNINGS
The Series LFII (TY3596) Residential
Concealed Pendent Sprinklers de-
scribed herein must be Installed and
maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association, in addition to the
standards of any other authorities hav-
ing Jurisdiction. Failure to do so may
Impair the performance of these de-
vices.
The owner is responsible for maintain-
ing their fire protection system and de-
vices In proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
with any questions.
SprinkleriModel
Identification
Number
SIN TY3596
JANUARY, 2006
Aft
Technical
Data
Approvals:
UL and C-UL Listed.
Maximum Working Pressure: -if 175 psi (12,1 bar)
Discharge Coefficient:
K = 4.9 GPM/ps1112 (70,6 LPM/ba
Temperature Rating:
160°F/71°C Sprinkler with
135°F/579C Cover Plate
Vertical Adjustment:
1/2 inch (12,7 mm)
Finishes:
Cover Plate:
Flat White, Bright White, Chrome, or
Custom
Physical Characteristics:
Body ..............Brass
Cap ..............Bronze
Saddle .............Brass
Sealing Assembly ..........
Beryllium Nickel w/ Teflorit
Soldered Link Halves .....Nickel
Lever .............Bronze
Compression Screw ......Brass
Deflector ......Copper or Brass
Guide Pin Housing .....Bronze
TFP442
Page 2 of 4 1FP442
Minimum Flow (b) and
Maximum Maximum Residual Pressure
Coverage Spacing For Horizontal Ceiling
Area (°) Ft. (Max. 2 Inch Rise
Ft. x Ft. (m) for 12 inch Run)
(m x m)
16OFl71°C
Sprinkler
12x12 12 13 GPM (49,2 LPM)
(3,7 x 3,7) (3,7) 7.0 psi (0,48 bar)
14x14 14 13 GPM (53,OLPM) (4,3 x 4,3) (4,3) 7.0 psi (0,48 bar)
16x16 16 I3 GPM (60,6LPM) (4,9 x 4,9) (4,9) 7.0 psi (0,48 bar)
18x18 18 17 GPM (64,3 LPM) (5,5 x 5,5) (5,5) 12.0 psi (0,83 bar)
20 x 20 20 20 GPM (75,7 LPM)
(6,1 x 6,1) (6,1) 16.7 psi (1,15 bar)
For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the
next highest coverage area for which hydraulic design criteria are stated.
Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated
using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.
TABLE A
NFPA 13D AND NFPA 13R WET PIPE HYDRAULIC DESIGN CRITERIA
FOR THE SERIES LFII (TY3596) RESIDENTIAL CONCEALED PENDENT SPRINKLER
Guide Pins ......Stainless Steel
Support Cup ..........Steel
Cover Plate ..........Copper
Retainer ............Brass
Cover Plate Ejection Spring .....
.Stainless Steel
tDuPont Registered Trademark
Operation
When exposed to heat from a fire, the
Cover Plate, which is normally sol-
dered to the Support Cup at three
points, fails away to expose the Sprin-
kler Assembly. At this point the Deflec-
tor supported by the Arms drops down
to its operated position. The fusible
link of the Sprinkler Assembly is com-
prised of two link halves that are sol-
dered together with a thin layer of sol-
der. When the rated temperature is
reached, the solder melts and the two
link halves separate allowing the sprin-
kler to activate and flow water.
Design
Criteria
The Series LFli (1Y3596) Residential
Concealed Pendent Sprinklers are UL
and C-UL Listed for installation in ac-
cordance with the following criteria.
NOTE
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufacturer's
recommendations that may be accept-
able to the Authority Having Jurisdic-
tion.
System Typo. Only wet pipe systems
may be utilized.
Hydraulic Design. The minimum re-
quired sprinkler flow rate for systems
designed to NFPA 130 or NFPA 13R
are given in Table A as a function of
temperature rating and the maximum
allowable coverage areas. The sprin-
kler flow rate is the minimum required
discharge from each of the total
number of "design sprinklers" as
specified in NFPA 130 or NFPA 13R.
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
Is to be the greater of the following:
The flow rates given in Table A for
NFPA 13D and 13R as a function of
temperature rating and the maxi-
mum allowable coverage area.
A minimum discharge of 0.1 gpm/sq.'
ft. over the "design area' comprised
of the four most hydraulically de-
manding sprinklers for the actual
coverage areas being protected oy
the four sprinklers.
Obstruction To Water Distribution.
Locations of sprinklers are to be in
accordance with the obstruction rules
of NFPA 13 for residential sprinklers.
Operational Sensitivity. The sprin-
klers are to be installed relative to the
ceiling mounting surface as shown in
Figure 3.
Sprinkler Spacing. The minimum
spacing between sprinklers is 8 feet
(2,4 m). The maximum spacing be-
tween sprinklers cannot exceed the
length of the coverage area (Ref. Ta-
ble A) being hydraulically calculated
(e.g., maximum 12 feet for a 12 ft. x
12 ft. coverage area, or 20 feet for a 20
ft. x 20 ft. coverage area).
Installation
The Series LFll (TY3596) must be in-
stalled in accordance with the follow-
ing instructions:
NOTES
Damage to the fusible Link Assembly
during installation can be avoided by
handling the sprinkler by the support
cup only (i.e., do not apply pressure to
the fusible link Assembly).
A leak tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of 7
to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi-
03/27/2885 89:53 7148782165 FIRE SPEC INC PAGE 83
QUICK RESPONSE
A UTOMA TIC SPRINKLERS
GL SERIES
UPRIGHT'PENDENT
VERTICAL SIDE WALL
HORIZONTAL SIDEWALL
DESCRIPTIONAND OPrioN CONVENTIONAL (OLD STYLE)
The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule
as the thermosensitive element. Tlis provides sprinkler operation approximately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appear-
ance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. it offers the additions) feature of greatly Increased safety to life and Is available In various styles, orifices, temp.rare ratings and finishes to meet
many varying design requirements. Quick Response Sprinklers QUICK RESPONSE should be used advisedly and under the direction of approving UPRIGHT CONVENTIONAL authorities having jurisdiction.
The heart of Globe's CL. Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains
a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands Increasing the internal pressure. At
the prescribed temperature the Internal pressure within the ampule
exceeds the strength of the glass causing the glass to shatter. This
results in water discharge which Is distributed in an approved
pattern depending upon the deflector style used.
QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL
See reverse side for Approvals and Specifications. EIPIWALL
Temperature Ratings - I 35°F (57°C). I 55°F (68°C), 175°F (79*C).
200°F (93°C). 286°F (141°C).
Water Working Pressure Rating. 175 psi (12 Bars).
Factory tested hydrostatically to 500 psi (34 Bars).
1(0
41 Maximum low temperature glass bulb rating is .67°F (.55°C).
Frame - bronze • Deflector- brass • Screw - brass
Bulb seat copper • Spring - nickel alloy • Seal - teflon QUICK RESPONSE
Bulb - glass with alcohol based solution. 3mm size. HORIZONTAL SIDEWALL.
SPRINKLER I BULL I j
P4.F.P,A. MAXIMUM
EMPERATURES COLOR CEILING TEMPERATURE
CLASSIFICATION)jAVAILAIRL&I
ORDINARY OUNGE/RED
INTERMEDIATE YELLOWIGREEN
HIGH BLUE
4077 AIRPARK DRIVE, £TAP4DH, MICIUGAN 4ISS 99-$46-4553 -. FAX $446-,23 I
JUNE 2001 A.20 BULLETIN GL56 IS. REV. #5
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL.
ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795.
ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040.
LICENSE : 772285
DESIGNER : STEVE PETRI
DATE : 12-10-2007
FILE : ZEZELJ
JOB NAME : ZEZELJ RES.TWO HEAD CALC 16 X 16
LOCATION : 2832 CAZADERO DRIVE
DESIGN DATA.
DESIGN CRITERION: TWO HEAD CALC 16 X 16
MIN SPR FLOW 13 Gpm
AREA PER SPRINKLER
TOTAL CALCULATED AREA
TOTAL SPRINKLERS CALCULATED
FLOW DATA.
TOTAL SPRINKLER FLOW
DOMESTIC DEMAND
TOTAL WATER REQUIRED
BASE OF RISER NODE: B FLOW:
256 Sq Ft Thew pLui hit \,: been reviewed for apparent compliance
with the oirrem applicable codes and standards in force
512 Sq Ft this review in support cit an application Ira building
iii the un sdiction The owner or contractor may util ize
permit wi h the express understanding hat this review
n no way relieves the owner or con I actor or their 2 prokssitiiial engineer or architect for sole responsibility
for full compliance with said codes and standards:
including the building code or for any responsihilty for
deficiencies. errors, omissions or negligence in these
plaits whether or not noted in this review.
Date: 2(V(O1 Rcviewer)
£flntA flt?A I 2 6 . 1 Gpm
0 RECOMMENI) APPROVAL. AS NOTED
5 (nm _________________ -
31.1 Gpm
31.1 Gpm PRESSURE: 25.8 Psi
AUTHORITY HAVING JURISDICTION : CARLSBAD FIRE
PHONE
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL.
ENGINEERS : PREMIER FIRE PROTECTION. (619)-659--9795.
ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040.
Date: 12-10-2007 File: C:\WINDOWS\ZEZELJ.RES
JOB : ZEZELJ RES.TWO HEAD CALC 16 X 16
Page 1
SOURCE I STATIC : 91.0 Psi RESIDUAL : 90.0 Psi FLOW : 26 Gpm
DESIGN I SPRINKLER MANUF : TYCO MODEL : LF11 4.9
I SPRINKLER Q : 13.0 Gpm VALVE : .0 Psi
SPRINKLER P : 7.0 Psi METER : 13.0 Psi
NODE ELEVATION K- PRESSURE DISCHARGE
NO. Feet ----------------------------------------------------------- FACTOR Psi Gpm
1 8.0 4.9 7.0 13.0
2 8.0 4.9 7.2 13.1
3 8.0 7.4
4 8.0 10.7
5 8.0 18.0
T 8.0 20.2
B .0 25.8 5.0 DOME
A .0 32.6
M .0 35.9
S .0 SOURCE 52.5 31.1
SPRINKLERS FLOWING
AREA PER SPRINKLER
TOTAL DESIGN AREA
MIN SPRINKLER FLOW
REQUIRED DENSITY
COMPUTED DENSITY
TOTAL SPRINKLER FLOW
TOTAL DOMESTIC FLOW
TOTAL WATER REQUIRED
TOTAL SPRINKLER PRESS
WATER METER LOSS
VALVE FIXED LOSS
SUPPLY PRESS AVAILABLE
DEMAND PRESS REQUIRED
PRESSURE CUSHION
MAXIMUM VELOCITY
2
256 SqFt
512 SqFt
13 Gpm
.051 Gpm/Sq Ft
.051 Gpm/Sq Ft
26.1 Gpm
5 Gpm
31.1 Gpm
39.5 Psi
13.0 Psi
.0 Psi
Copyright (2003)
89.6 Psi by
52.5 Psi Hydronics Engineering
37.1 Psi 34119 Fremont Bi, Suite 609
Fremont, Ca., 94555
12.1 F/S (510) 487-9160
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.31 - SUBMITTAL. Page 2
ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795.
ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040.
Date: 12-10-2007 File: C:\WINDOWS\ZEZELJ.RES
JOB : ZEZELJ RES.TWO HEAD CALC 16 X 16
PIPE BEG FLOW K-FACTOR LENGTH C-FACTOR PRESSURE
NO. Gpm FITTING TYPE FTG FR- LOSS Psi
END DIAMETER TOTAL (Psi/Ft)
1 q= 13.0 K=
-------------------------------------------------------------------------------
4.9 L= 7.0 Pt 7.0 Pt 7.0
1 Q= 13.0 F= B F= 5.0 C= 150 Pe .0 Pv -.1
Vel= 4.4 D= 1.101 TL= 12.0 .0307 Pt .4 Pn 6.9
3 Pt 7.4
2 q= 13.1 K= 4.9
--------------------------------------------------------------------------
L= 3.0 Pt 7.2 Pt 7.2
2 Q= 13.1 F= B F= 5.0 C= 150 Pe .0 Pv -.1
Vel= 4.4 D= 1.101 TL= 8.0 .0312 Pf .2 Pn 7.0
3 Pt 7.4
3 q= .0 K= .0
--------------------------------------------------------------------------
L= 20.0 Pt 7.4 Pt 7.4
3 Q= 26.1 F= B4R F= 9.0 C= 150 Pe .0 Pv -.5
Vel= 8.8 D= 1.101 TL= 29.0 .1115 Pt 3.2 Pn 6.9
4 Pt 10.7
4 q= .0 K= .0
--------------------------------------------------------------------------
L= 45.0 Pt 10.7 Pt 10.7
4 Q= 26.1 F= BL8R F= 20.0 C= 150 Pe .0 Pv -.5
Vel= 8.8 D= 1.101 TL= 65.0 .1115 Pf 7.2 Pn 10.2
5 Pt 18.0
5 q= .0 K= .0
--------------------------------------------------------------------------
L= 13.0 Pt 18.0 Pt 18.0
5 Q= 26.1 F= L F= 7.0 C= 150 Pe .0 Pv -.5
Vel= 8.8 D= 1.101 TL= 20.0 .1115 Pf 2.2 Pn 17.4
T Pt 20.2
T q= .0 K= .0
--------------------------------------------------------------------------
L= 9.0 Pt 20.2 Pt 20.2
6 Q= 26.1 F= SCRR F= 10.0 C=.150 Pe 3.5 Pv -.5
Vel= 8.8 D= 1.101 TL= 19.0 .1115 Pf 2.1 Pn 19.7
B Pt 25.8
B q= 5.0 DOME
--------------------------------------------------------------------------
L= 5.0 Pt 25.8 Pt 25.8
7 Q= 31.1 F= LLLB F= 26.0 C= 150 Pe .0 Pv -1.0
Vel= 12.1 D= 1.025 TL= 31.0 .2185 Pf 6.8 Pn 24.8
A Pt 32.6
A q= .0 K= .0
--------------------------------------------------------------------------
L= 110.0 Pt 32.6 Pt 32.6
8 Q= 31.1 F= LLEECC F= 18.0 C= 150 Pe .0 Pv -.2
Vel= 5.0 D= 1.59 TL= 128.0 .0258 Pt 3.3 Pn 32.5
M Pt 35.9
N q= .0 K= .0
--------------------------------------------------------------------------
L= 10.0 Pt 35.9 Pt 35.9
9 Q= 31.1 F= BG F= 6.0 C= 150 Pe .0 Pv -1.0
Vel= 12.1 D= 1.025 TL= 16.0 .2185 Pt 3.5 Pn 35.0
S Pt 39.5 --------------------------------------------------------------------------
Meter =13.0
S Q= 31.1 <<< SOURCE >>> Pt 52.5
E=>45-E1b L=>90-E1b B=>TeeBch R=>TeeRun C=>CouPlg S=>SwgChk G=>GatVlv
HYDRONICS: RESIDENTIAL FIRE SPRINKLER HYDRAULICS 4.2 - SUBMITTAL.
ENGINEERS : PREMIER FIRE PROTECTION. (619)-659-9795.
ADDRESS : 12651 Ridgeton Drive, Lakeside CA 92040.
DATE : 12-10-2007 FILE : C:\WINDOWS\ZEZELJ.RES
JOB : ZEZELJ RES.TWO HEAD CALC 16 X 16
PSI FIRE SPRINKLER HYDRAULIC GRAPH
100
90
80
70
60
50
40
30
20
10
0
10 15 20 25
0 Supply Curve
Static : 91.0
Resid : 90.0
Flow : 26.0
30 35 40 45 50
FLOW - Gpm
S Demand Curve
Avl Pr : 89.6 @ 31
Req Pr : 52.5 @ 31
Pr Cush: 37.1
Copyright: Hydronics Engineering, 2003.
34119 Fremont Bi, Suite 609,
Fremont, CA. 94555.
(510) 487-9160.