Loading...
HomeMy WebLinkAbout2506 EL CAMINO REAL; ; FA090034; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA090034 2506 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: Lot #: 0 Status: ISSUED Applied 7/9/2009 Approved: 7/13/2009 Reference No.: Issued: 7/13/2009 PC #: Inspector: Project Title: CHILDREN'S VILLAGE FIRE ALARM PLAN CHECK/INSPECTION Applicant: Owner: Fees ($) Add'l Fees ($) Total ($) Balance ($) L230 0 230 0 fAo9oo 4 CHILORENS VILLAGE, INC. 2506 EL CAMINO REAL, CARLSBAD, CA Fire Alarm Submittal 07/07/09 0 1 0 Submitted By; CLS Security Electronics Contact: Dan Dorgan 9295 Chesapeake Dr. San Diego, CA. 92123 License #675676/Type C 1 CHILDRENS VILLAGE, INC. Fire Alarm Submittal Equipment List Qy Description Model Manufacture CSFM# 1 Fire Alarm Panel 5208 Silent Knight 7165-0559:137 1 Fire Alarm Annunciator 5235 Silent Knight 7165-0559:137 25 Smoke Detector 2W-B System Sensor 7272-1653:152 4 Heat Detector 5602 Sstem Sensor 7270-1653:167 5 Manual Pull Station BG-12 Silent Knight 7150-0075:184 13 Horn/Strobe P2R System Sensor 7125-1653:188 8 Strobe SR System Sensor 7125-1653:186 1 Horn/Strobe W.P. HR System Sensor 7135-1653:189 Lot Wire 18/2 Cond. (Notification) Lot Wire 18/2 & 18/4 Cond. (Initiation) Lot Wire 1 8/4Cond. (Annunciator) Lot Wire 2414 THWN (Underground) 9 S Model 5208 Fire Alarm Control Panel with Digital Communicator L t" The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. S a Features 10 zones, 8 Class B (Style B) and 2 Class A (Style D) or Class B (Style B) zones, expandable to 30 zones Supervised zone expanders and I/O modules can be mounted remotely from the main control panel Event History Buffer (150 events) with date/time stamp All zones are compatible with 2- or 4-wire detectors 8 selectable/programmable output patterns for notification appliance circuits Built-in Digital Alarm Communicator Transmitter (DACT) 4 Notification Appliance Circuits 4 programmable general purpose relays Programmable smoke verification, pre-alarm delay, cross zoning and enhanced verification mode features that can help minimize false alarms Programmable from the built-in control panel touchpad, remote annunciator, or Windows® SKSS downloading software Direct connect port for on-site up/downloading with Windows® SKSS downloading software Built-in walk test feature Single or dual interlock water releasing capability Plex door option combines a dead front cabinet door with a clear window, limiting access to the panel while providing single button operation of the reset and silence functions Programmable AC trouble relay Built-in synchronization for appliances from AMSECO®, Gentex®, Faraday, System Sensor®, and Wheelock® Programmable date settings for Daylight Saving Time Clock source setting options for 50 Hz, 60 Hz, or internal (uses the panel's internal clock) Specifications Operating Voltage: 24 VDC Primary AC: 120 Vrms @ 60Hz, 2A Total DC Load: 6 Amp Current Draw: Standby: 140 mA Alarm: 460 mA Flush Mounting Dimensions: Height: 24.75" (62.9 cm) Width: 14.5" (36.8 cm) Depth: 3-7/16" (8.73 cm) with 5/8" protruding Overall Dimensions: Height: 26-3/8" (67 cm) Width: 17-3/16" (43.66 cm) Total Depth: 4" (10.16 cm) Operating Temp: 32° to 120° F (0° to 49° C) Humidity: 10 - 93% noncondensing Optional Accessories SK-5235 LCD Remote Annunciator SK-5217 10 Zone Expander (2 max. per system) SK-5280 Status Display Module (8 max. per system) 7181 Fire Zone Converter 5220 Direct Connect Module 5824 Serial/Parallel Printer Interface Module --I--I-- SK-5208 SKSS Downloading Software Plex-2 Door Option Listings and Approvals UL Listed CSFM Listed MEA approval 429-92-E Vol. XIII SILENT KNIGHT by Honeywell S Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. in addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 4 -Po Telephone Line 2 Direct Connect I For On-Site Programming 2 Class A (Style D) D or Class B (Style B) Ej Initiation Circuits -- Programmable i + Form C Relays 8ClassB(StyleB)4 Initiation Circuits : Li To AC D SILENT This document is not intended to be used for installation purposes. We try to KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight by Honeywell 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. MADE IN AMERICA FORM# 350318 Rev B. 11/05 Copyright © 2005 Silent Knight Notification Appliance Circuits 5235 Remote Annunciators ti IH--- SBUS Devices 5280, 5217, & 5824 S SK-5235 Remote Annunciator Program and Operate the SK-5208 FACP from a Distance with the SK-5235 Remote Annunciator. The SK-5235 remote annunciator provides remote annunciation for the SK-5208 Fire Alarm Control Panel. The SK-5235 performs all system operations. It also provides trouble and alarm information and can be used for programming. The SK-5208 can support up to six 5235 Remote Annunciators. Operation When the system is normal and 1 receiving AC power, the power LED is on and all other LEDs are off. Other LEDs turn on as the conditions occur. Users identify themselves to the - * control panel by entering a code on the annunciator. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information. Features SK-5235 Remote Annunciator 2-line 16-character LCD display Indicates Trouble Alarm Supervisory, and System Status Specifications Ordering Information conditions with LEDs and LCD Operating Voltage: 24 VDC SK5235 display Current Draw: Remote Annunciator Each SK-5235 is individually Standby: 30 mA supervised by the SK-5208 Alarm: 50 mA FACP Dimensions: Compatible Products Up to 6 per SK-5208 FACP Width: 7-3/16" SK5208 Operation and appearance Height: ,8.26 cm) Fire Alarm Control Panel comparable to the control (12.7 cm) panel's on-board annunciator Depth: 1-1/8" Can be wired up to 1500 ft from (2.86 cm) FACP Operating Temp: 32° to 120° F OPR operator's key ships with (0° to 49° C) SK-5235, this key can be used Maximum Wiring to perform user operations, but Distance: 1500ft will not open the control panel door Approvals MEA429-92-E SILENT CSFM 7165-0559:137 KNIGHT UL Listed by Honeywell S SK-5235 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model SK-5235 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of supporting up to 6 supervised SK-5235. Module shall be designed to mount on a dual gang electrical box with 18 gauge to 14 gauge wire. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA U KNIGHT keep our product information up-to-date and accurate. We cannot cover all FORM# 350321 Rev B 1/07 specific applications or anticipate all requirements. All specifications are Copyright © 2007 Silent Knight subject to change without notice. For more information, contact Silent Knight IYY Hm oswf4 . . 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Model SK-5208 Fire Control/Communicator Installation and Operation Manual 0 Table 3-2: Current Draw Calculations Device # of Devices Current per Device Standby Current Alarm Current For each device use this formula: tins column X 1 his column = Current per number of devices. SK-5208 Fire Panel (Current draw from battery) Standby: 140 mA 140 mA Alarm: 460 mA 460 mA Panel Accessories SK-5217 Zone Expander (2 max.) Standby: 60 mA mA Mann: 260 mA mA 5824 Serial/Parallel Interface Gateway Module max., y: 45 mA mA Alarm: 45 mA mA 5220 Direct Connect Standby: 15 mA mA Alarm: 15 mA mA SK-5235 Annunciator (6 max.) Standby: 30 mA mA Mann: 50 mA mA SK-5280 Status Display Module (8 max.) Relay (max.) Per Standby: 10 mA mA Alarm: 80 mA mA Outputs output 100 mA mA Max. 700 mA mA 7181 Zone Converter Standby: 35 mA mA Alarm: 65 mA mA Total System Current Smoke Detectors Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Standby: mA mA Alarm: mA mA Smoke Detector Current mA mA Notification Appliances Alarm: mA mA Alarm: mA mA Alarm: mA mA Alarm: mA mA Notification Appliances Current mA Additional Devices Standby: mA Alarm: mA Standby: mA Alarm: mA Additional Devices Current mA Total current ratings of all devices in system (line A + line B + C +D) mA mA Total current ratings converted to amperes (line E x .001): A A Number of standby hours (24 or 60 for NFPA 72, chapter 1, 1-5.2.5): H Multiply lines F and G. Total standby AH AH Alarm sounding period in hours. (For example, 5 minutes = .0833 hours) H Multiply lines F and I. Total alarm All AH *Add lines H and J. Total ampere AH hours required Use next size battery with capacity greater than required. 0 3-6 P/N 151204 A [I I] C D E F ci H J K Control Panel Installation 3.63 Maximum Battery Standby Load Table 3-3 shows the maximum battery standby load for the SK-5208 based on 24 and 60 hours of standby. The standby load calculations of line D in the Current Draw Calculation Worksheet (Table 3-2) must be less than the number shown in Table 3-3 for the battery size used and standby hours required. Batteries larger then 18 AH will not fit into the SK-5208 cabinet and must be housed in the AB-33 Accessory Battery Cabinet. See Section 3.8 for battery installation. Table 3-3: Maximum Battery Standby Load Rechargeable Battery Size Max. Load for 24 hrs. Standby, 5 mins. Alarm *Max. Load for 60 hrs. Standby, 5 mins. Alarm 7 A 270 m 105 m 12 A 475 m 190 m 18 A 685niA 270 m 35 A l.IA 450 m * Requiredfor NFPA 72AuxiliaryProtected Fire Alarm systems for Fire Alarm Service (City Box) andRemote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/Transmitter (DACT). Silent Knight does not support the use of batteries smaller than those listed in Table 3-3. If you use a battery too small for the installation, the system could overload the battery resulting in the installation having less than the . required 24 hours standby power. Use Table 3-2 to calculate the correct battery amperes/hour rating needed for your installation. 0 PIN 151204 3-7 Control Panel Installation 3.8 Backup Batteries The control panel battery charge capacity is 7.0 to 35.0 AH. Use 12V batteries of the same AH rating. Determine the correct AH rating as per your current load calculation (see 3.6.2). Wire batteries in series to produce a 24-volt equivalent. Do not parallel batteries to increase the AR rating. Batteries larger than 18 AR (not to exceed 35 AH) use the RBB Remote Battery Box. It is recommended that you replace the batteries every five years. The following steps and diagram explain how to connect the batteries. Connect the black wire to the negative (-) side of battery #1. Connect the jumper wire provided (P/N 140694) from the positive (+) side of battery #1 to the negative side of battery #2. Connect the red wire to the positive (+) side of battery #2 14 - RED Control Panel Black ( B ( attery Jumper PIN Note: Replace batteries 140694) every 5 years. Shipped With Panel Battery #1 - + Battery #2 - - UL Listed I2VDC Battery UL Listed I2VDC Battery Gell Cell Cell Cell Apply AC power connecting the batteries to the power supply to prevent arcing on battery terminals. Note: The total current draw on smoke power, accessory power, and notification device outputs must not exceed 6A. 0 PIN 151204 3-9 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:137 Page 1 of I CATEGORY: Control Unit (Non High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove, MN 55369 Contact: Michael Mclsaac (763) 493-6400 FAX (763) 391-5464 DESIGN: Model SK-5208 fire alarm control unit. Power-limited, automatic, manual, remote station, central station, waterflow, Releasing Device Service, and sprinkler supervisory services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: SK5208 Control Unit SK-5220 Direct Connect Module SK-5280 Status Display Module SK-5217 Zone Expander SK-5235 Remote Annunciator SK-2190 Enclosure SK-7181 Zone Converter INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed compatible initiating and indicating devices. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: 1. For the Alarm Verification Feature (delay of fire alarm), the maximum Retard/Reset/Restart shall not exceed 30 seconds. Burglary and other non-fire functions were not examined. 08-17-2006 jw '. This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 18, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division System Sensor 2-wire Compatibility for SK-5208 by Silent Knight Page 1 of 1 0,-:--\ SYSTEM w SENSOR a1vonccd idecs. odvon.ceo oIuflons 2-wire Compatibility for Manufacturer: Silent Knight Model: SK-5208 n Detector Base Model Max Zone Model Style EOL Zone Model Detectors ID 1151 B110 LP, 16 5208, 5217 B D 7628/ 243 B401 ' N/A 2100AT N/A 20 5208, 5217 B D 7628 / N/A 243 2100S N/A 20 5208, 5217 B D 7628 / N/A 243 2100TR N/A 1 5208, 5217 B D 7628 / N/A 243 2100TS N/A 20 5208, 5217 BD 7628 / 243 N/A 2151 B110 LP, 16 5208, 5217 B D 7628/ 243 B401 ' N/A 2151T B110LP, 16 5208, 5217 B D 17628 / 243 B401 ' N/A 2W-B N/A 20 5208, 5217 B D* 17628 / N/A 243 2WT-B N/A 20 5208, 5217 B D* 17628 / N/A 243 2WTA-B N/A 20 SK-5217, FC- B D" 7628/ 243 5217 ' N/A 2WTR-B N/A 1 SK-5217, FC- B D* 7628 / 243 5217 ' N/A 4451HT 8401B 20 5208 B/D 4.7K 243 5451 IB401B 120 5208 BID 4.7K 124J * CAUTION: Fire alarm control panels vary by manufacturer on the implementation of Style D (also called Class A) circuits. Therefore, the only way to insure the proper operation of 2-wire i3 smoke detectors on a Style D initiating device circuit (IDC) is to use a System Sensor 2W-MOD2 module. Any 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA- B, or 2WTR-B) wired in the Style D initiating device circuit (IDC) configuration requires the use of a System Sensor 2W-MOD2 module. http://www. systemsensor. com/html/2wirprnt.php?page=2-wire&panel=SK-5208&co=SiI. 10/30/2007 SYSTEM SENSORS Photoelectric Smoke Detectors System Sensors series smoke detectors represent significant advancement in conventional detection. The il family is founded on three principles: installation ease, intelligence and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port . • In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch - Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the j3 protocol, the EZ Walk loop test feature is available on two-wire P detectors.This feature verifies the initiating loop wiring by providing LED status indication at each detector. Installation ease.The 3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads.The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, P heads plug in to the base with a sin iple Stop-Drop 'N Lock" action. Intelligence. P detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the P line to minimize nuisance alarms. Two-wire P detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 boo test/maintenance module, or to a panel equipped with the P protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent per-foot-obscuration. Agency Listings & <~> 0 MEAMSFM LISTED APPROVED approved approved SOil I 091146 7272-1209:210 290-01-E 2093 (j Smoke Detector Specifications S Smoke detector shall be a System Sensor 13 Series model number_______ listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-B, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4W1-B) with thermal sensor rated at 135°F (57.2°C). The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors, Wring connections shall be made by means of SEMS screws. Thedetector shall allow pro-wiring of he base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UI. smoke box, The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, out olsensitivity, alarm, and freeze trouble (Model 2W1B,4WT-B) conditions,When used in conjunction with the 2W-MOD2 module, 2-wire models snail include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the circuit without testing each detector individually. : Operating Voltage Nominal: 12/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: SO pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 o (178 grams) Operating Temperature Range 2\A/-B and 4W-B: 32°1-120°F (O'C-49'C); 2WT-B and 4WT-B: 32°F-100°F (0°C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 135°F (57.2°C) fixed FreezeTrouble 2WPB and 4WT-B only: 417 (.5°C) Sensitivity 2.5%/ft. nominal Input Terminals 14-22 AWG Mounting 314-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling ...n ° LED Mode Green LED Red LED Condition Duration Power up Blink every tO seconds Blink every 10 seconds Initial LED status ;ndicatlon 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm, off Solid i1Tt'7T1Information Model Thermal Wiling Alarm Current - - _. . 2W-B No 2-wire 130 mA max. limited by control panel 2W1-B Yes 2-wire 130 mA max. limited by control panel 4W-13 No 4-wire 20 mA @ IN 23mA @ 24V 4W1B Yes 4-wire 20mA@ 12V,23mA@24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal I replacement tool SENS-RDP Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter fl 7i Ctem Sensc "STEM __ 3825 Ohio Avenue St. Charles, IL 60174 ISENSOR' Phone: 600- SENSOR2. Fax: 630-377-6495 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL F7RE is LISTING No. 7272-1653:152 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-8 photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (1350 F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or * recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 5600 Series Mechanical Heat Detectors System Sensors 5600 series mechanical hear detectors offer a low-cost means for property protection against fire, and for non-life-safety installation5 where smoke jetectors are inappropriate. Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601 P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang -- 3.5" and 4 Octagonal 4" square with square to round plaster ring Reversible mounting bracket Agency Listings ®4j>MEA 0 LISTED APPROVED approved 52101 3016008 1913-03 F. 72701209.227 Multiple configurations. The 5600 series offers a full-line of configurations to acconmocate a broad range of applications. Both single- and dual-circuirmodels are available for low- and high- temperature ratings with either fixed temperature or combination fixed temperature/fate-of-rise (FOR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation fiexibility.To satisfy a variety ofhstallarion needs, the 5600 series easily rrounts to single-gang and octagonal back boxes. And these models accommodate fcur-square back boxes, when used with a square to round platter ring. The reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series prvides clear markings on the exterior of the unit to en sure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature raring, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/rate-of-rise units are marked EX/ROR The 5600 series also provides a post activation indicator in the fom of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the un:t in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number_ listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire W Protective Signaling Systems. The detector shall be either a single-circu it or a dual-circuit type, normally open. The detector shail berated for activation at either 135°F (57°(.) or 194°F 90°Q, and shall activate by means of afixed temperature thermal sensor, or a combination fixed ternperature/iate-of-l& thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F 8.3°C) per minute. The detector shall include a reversible mounting bracketfbr mounting to 31,11 and 4-inch octagonal, single ganq, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate-of-rise element of combination fixed temerature/rate-of-rise models shall be restorable, to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum installation Temperature 5601P. 5603,562 1, and 5623:100°F (38°C) 5602,5604,5622, and 5624: 150°F (65ffC) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.31 Alarm Temperature 5601 P.5603,5621, and 5623:135'F (57°C) 5602, 5604, 5622, and 562: 194°F (90°C) Weight 6 oz. (170 grams) Rate-of-Rise Threshold 15°F (8,3°C) rise per minute (models 5601 P.5602,5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Operating Voltage / Contact Ratings 6-125VAC / 3A 6-28VDC/1A 125VDC / 0.3A 25OVDC/0.1A Input Terminals 14-22 AWG nKD X xi )w mm 5601P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature/ Rate-or-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature/ Rare-of-Rise 50 thet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (2.62m x 7.62m) 5621 Dual Lettering 35°F (57°C) Fixed lemperature/ Rate-of-Rise 50 feet x SO feet (I 5.241n x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.21n) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature °NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. Th SYSTE.14 325 Ohio Avenue. SL Charles, IL 60174 SENSOR ° Phone: 800-SENSOR2. Fax: 630-377-6495 25 feet x 25 feet C162m x 7.62m) 0 2c1J6 Sysre.t Son,,,, t PsoJi,&I(&1rmft1,Iix1l thie 51000,0w ol this dot, shoot 'US051 W2. 1111k.01676 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7270-1653:167 Page 1 of I CATEGORY: Heat Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Intl Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 5601, 5601P, 5602, 5621, and 5622 combination fixed-temperature and rate-of- rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models Fixed Temperature Electrical 5601, 5601P 135°F 6-125V AC, 3A 5602 194°F 11 5603 135°F 6-28V DC, 1A 5604 194°F 1. 5621 135°F 125V DC, 0.3A 5622 194°F 11 5623 135°F 250V DC, 0.IA 5624 194°F INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances • and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: 0 Authorized By: JUNE 30, 2009 Listing Expires June 30, 2010 FRANCIS MATEO, Program Coordinator Fire Engineering Division June 30, 2000 DF-52004 F-050 S (a FIreuTeALarms www.firellle.com GENERAL The Fire'Lite BG-12 Series is a cost-effective, feature- packed, non-coded series of manual fire alarm pull sta- tions. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series fea- tures a variety of models including single- and dual-action versions. The BG-12 Series provides Fire'Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down posi- tion to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.25 mm2). Terminal numbers are molded into the backplate, elimi- nating the need for labels. BG..I2 Series Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices c®us California State Fire Marshal 7150-0075:184 LISTED (except BG-I2LOB) S711 < > APPROVED Wel Switch contacts are normally open. Can be surface (with SB-b) or semi-flush mounted. Semi-flush mount to a standard single-gang, double- gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (12.7 mm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the popular BG-10 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, Point-of-Purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. This document is not intended to be used for installation purposes. We try to keep our - product information up-to-date and accurate. We cannot cover all specific applica- tions or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, EI =6 :b dl ajL% A, Connecticut 06472. Phone: (800) 627-3473, Toll Free FAX: (877) 699-4105, FAX Beck:(888) 388-3299. Made in the U.S.A. DF-52004 - Page 1 of 2 7 1.000" (25.40) 'I, Length Gauge 5.500" (139.70) n) 1.390" (35.306) CONSTRUCTION PRODUCT LINE INFORMATION Cover, backplate and operation handle are all molded Model of durable polycarbonate material. BG-12S . • Cover features white lettering and trim. Red color matches System Sensor's popular BG-12 SpectrAlertTM horn/strobe series. OPERATION BG-12L Description Single-action pull station with pigtail connec- tions, hex lock. Dual-action pull station with SPST NIO switch, screw terminal connections, hex lock. Same as BG-12 with key lock. S S The BG-I2 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking per- sons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bot- tom as a visible flag. Resetting the station is simple: in- sert the key or hex (model dependent), twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: 62004tb11 .op BG-12 SB-b Height: 5.500 inches 5.500 inches (13.97 cm) (13.97 cm) Width 4.121 inches 4.125 inches (10.4673 cm) (10.4775 cm) Depth: 1.390 inches 1.375 inches 1 (3.5306 cm) (3.4925 cm) Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A © 30 VAC or VOC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN® (or polycarbonate equivalent) with clearly visible operating in- structions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching backbox SB-10; or semi- flush mounting on a standard single-gang, double-gang, or 4(10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Sta- tions shall be Underwriters Laboratories listed. NOTE: The words "FIRE/FUEGO" on the BG-I2LSP shall appear on the front of the station in white letters, approximately 3/4" high. Page 2 of 2 - DF-52004 BG-12LSP Same as BG-12L with English/Spanish (FIRE! FUEGO) labeling. BG-121-013 Same as BG-12L with "outdoor use" listing. Includes WBB outdoor backbox, and sealing gasket. (FM Pending) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION ___ OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7150-0075:184 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds (203) 484-7161 FAX (203) 484-7309 DESIGN: Models BG-12, BG-125, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-12LSP, BG-125P, BG-12LR, BG-12LRA, BG-I2LAO, BG-I2LAOB, BG-12-LO, BG-I2LOB, BG-I2LPS, BG-I2LPSP, BG-I2SL, UT-PSI and UT- PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-I2WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when S installed with Model WP-10 back box. Models BG-LAOB and BG-I2LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. * These manual pull boxes do not meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:199 *updated 06-22-2009 fm " This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator 0 Fire Engineering Division SIGNALING ®4MEA LISTED APPROVED approved 54011 3023572 MEA452-05-0 55552 53593 0 7125-1653:1860nd00,,00bes) 7300-1653:187 (o.'tdoort'obes) 7125-1653:168 (horWst,obe, r51n,e,suooes) 7135-1653:189 (ho,ns, chines) SSTEM SENSOR Selectable Output Horns, Strobes, and Horn/Strobes SpectrAlertAdvance selectable-output horns, strobes, and horn/strobes are rich with features guaranteed to cut installation times and maximize profits. SPECTRA-ert S Features Electrically compatible with existing SpectrAlert products Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Plug-in design The SpectrAlert Advance series of notification appliances is designed to simpify installatiors, wth features such as plug in designs, instant feedbacc messagesto ensure correct installation of individual devices and 11 field-selectable candela settings for wall and ceiling strobes and born/strobes. Field selectable candela settings on wall and ceiling units: 15,15/75, When installing Advance products, first attach a universal mounting 30, 75,95, 110, 115, 135, 150, 177, 185 plate to a four-inc-1 square, four-inch octagon or double-gang Same mounting plate for wall- and ceiling-mount units junction box.The two-wire mounting plate attaches to a single-gang -------------,------------- junction box. 11011l1I0.J spllllCj 015 rriouriiirig ld165 101 C0F11lFlUI1 CF165LI 116510165 installation Tamper resistant construction Outdoor wall and ceiling products rated from —40°F to 151°F Design allows minimal intrusion into the back box Horn rated at 88+ dbA at 16 volts Rotary switch for horn tone and three volume selections Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn) outdoor requirements Outdoor products NEMA4X rated Compatible with MDL sync module Agency Listings Next, connect the notification appliance circuit wiring to the SEMS terminals on the mounthg p1ae. Finally, attach the horn, strobe jr horn/strobe to the mounting plate by inserting the produc:'s :abs in the mounting plate's grooves. The device will rotate into p:.si:ion, locking the product's pins into the mounting plate's termirals.The de'ice will temporarily hold in place with a catch until it is secured with a captured mounting screw. The SpectrAlert Advance series includes outdoor notification appliances. Outdoor str:bes and horn/strobes (two wire and four wire) are available for wall or ceiling. Outdoor horns are available for wall only. All System Sensor outdoor products are rated between minus 40 degree; Fahreil-eitand 151 degrees Fahrenheit in wet or dry applications. Advance Specifications S Genera) SpectrAlert Advance horns, strobes and horn/strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-Inch octagon back box or double-gang back box Two-wire products shall also mount to a single-gang 2 x 4 x 17/s-inch back box A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit" Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 0124 volts When used with the Sync-Circuit Module, 12-volt rated notification appliance circuit outputs shall operate between nine and 17.5 volts; 24-volt rated notification appliance circuit outputs shall operate between 17 and 33 volts, Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC, or full-wave rectified, unfiltered power supply. Strobes and horn/strobes shall have field-selectable candela settings including 15, 15/75, 30, 75,95,110,115,135,150,177,185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination The horn/strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn/strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder.The horn on horn/strobe models shall operate on a coded or non-coded power supply. Outdoor Products SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151 degrees Fahrenheit,The products shall be listed for use with a System Sensor outdoor/weatherproof back box with half inch and three-fourths inch conduit entries, Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal three Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a single pair of wires. The module shall mount to a 411/ x 4fl/ x 21/&4nch back bocThe module shall also control two StyleY (class B) circuits or one Style Z (class A) circuitThe module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) K Series Operating Temperature -40°F to 151°F (-40°C to 66°C) Humidity Range 10 to 93% non-condensing (indoor products) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12DC/FWRor regulated 24DC/FWR Operating Voltage Range' 8 to 17.5 V (12V nominal) or 16 to 33 V (24 nominal) Input terminal wire gauge 12 to 18 AWG Ceiling mount dimensions (including lens) 6.8-diameter x 2.5 high (173 mm diameter x 64mm high) Wall mount dimensions (including lens) 5.61 x 4.7-W x 2.5D (142 mm Lx 119 mm W x 64 mm D) Horn dimensions 5.61x4.7-Wx 13T2 (142 mm Lx 119 mmWx 33 mm D) Wall-mount back box skirt dimensions (BBS-2, BBSW-2) 5.91 x 5.0W x 2.2D (151 mm Lx 128 mm W x 56 mm D) Ceiling-mount back box skirt dimensions (BBSC-2, B)3SCW-2) 7.1 diameter x 2.25 high (180 mm diameter x 57 mm high) Wall-mount weatherproof back box dimensions (SA-WBB) 5.71 x 51W x 2.0D (145 mm Lx 130 mm W x 51 mm D) Ceiling-mount weatherproof back box dimensions (SA-WBBC) 7.1 diameter x 2.0 high (180 mm diameter x 51 mm high) Wall-mount trim ring dimensions (TR-HS,TRW-HS) 5.71 x 4.812W x 0.3512 (146mm Lx 122W mm x 9 D mm) Ceiling-mount trim ring dimensions (TRC-HS, TRCW-HS) 6.9- diameter x 035 high (176 mm diameter x 9 m high) Notes: Full Wave Rectified (FWR) voltage Is non-regulated, time varying power source that is used on some power supply and panel outputs, P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd 0 8-17.5 Volts 16-33 Volts Sound Pattern dB DC FWR DC FWR Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-temporal High 57 56 69 75 Non-temporal Medium 42 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 Coded Medium 44 51 56 69 Coded Low 40 46 52 50 UL Current Draw Data Candela 8-173 Volts DC FWR 16-33 Volts DC FWR Standard 15' 123 128 66 71 Candela Range 15/75' 142 148 77 81 30' NA NA 94 96 75' NA NA 158 153 95' NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 High 135 NA NA 228 207 Candela Range 150 NA NA 246 220 177 NA NA 281 251 185 NA NA 286 258 &- 17.5 Volts 16-33 Volts DC Input 15 15/75 15 15175 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-temporal High 141 152 91 100 116 176 201 221 229 Non-temporal Medium 133 145 75 85 102 163 187 207 216 Non-temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-temporal High 142 161 103 112 126 181 203 221 229 Non-temporal Medium 134 155 85 95 110 166 189 208 216 Non-temporal Low 132 154 80 90 105 161 184 202 211 DClnput 16-33 Volts 135 150 177 185 FWR Input 16-33 Volts 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-temporal High 255 270 303 309 Non-temporal High 233 248 275 281 Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267 Non-temporal Low 238 254 291 295 Non-temporal Low 214 229 256 262 Candela Derating For K series products used at low temperatures, listed candela ratings must be reduced in accordance with this table. Listed Candela 71 Candela rating at -40°F 15 Do not use below 32°F 15/75 30 /5 44 95 70 110 110 115 115 135 135 150 150 177 177 185 185 Horn Tones and Sound Output Data Switch Position Sound Pattern d8 8-17.5 Volts DC FWR 16-33 Volts DC FWR 24 Volt Nominal Reverberant Anechoic DC FWR DC FWR Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 3 Temporal tow 71 73 76 76 83 80 94 89 4 Non-temporal High 82 82 88 88 93 92 100 100 - 5 Non-temporal Medium 78 78 85 85 90 90 98 98 6 Non-temporal tow 75 75 81 81 88 84 96 92 7t Coded High 82 82 88 88 93 92 101 101 8t Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low /5 /5 81 81 88 85 96 92 tsettings 7,8, and 9 are not available on 2-wire horn/strobe. S SoectrAlert Advance Dimensions Wall-mount hom/strobes Ceiling-mount horn/strobes 7.1 Dia. S Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information Wall Horn/Strobes D2ft 2-wire Horn/Strobe, Standard c&, Red P21R-1 2-wire Horn/Strobe, High cd, Red P2RK 2-wire Horn/Strobe, Standard cd, Red, Outdoor P2111-1I 2-wire Horn/Strobe, High cd, Red, Outdoor P2W* 2-wire Horn/Strobe, Standard cd, White P2W1-r 2-wire Horn/Strobe, 1-11gb cd, White P4R 4-wire Horn/Strobe, Standard cd, Red P4RH 4-wire Horn/Strobe, High cd, Red P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor P4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor P4W 4-wire Horn/Strobe, Standard cd, White P4VVH 4-wire Horn/Strobe, High cd, White Wall Strobes SRt Strobe, Standard cd, Red SRWt Strobe, High cd, Red SRK Strobe, Standard cd, Red, Outdoor SRHK Strobe, High cd, Red, Outdoor SW Strobe, Standard cd, White SWH Strobe, High cd, White Ceiling Horn/Strobes PC2R 2-wire Horn/Strobe, Standard cd, Red PQRH 2-wire Horn/Strobe, High cd, Red PC2RK' 2-wire Horn/Strobe, Standard cd, Red, Outdoor PQRHK 2-wire Horn/Strobe, High cd, Red, Outdoor l)Q\ftJt 2-wire Horn/Strobe, Standard cd, White PQ\//Wt 2-wire Horn/Strobe, High cd, White PC4R 4-wire Horn/Strobe, Standard cd, Red PC4RH 4-wire Horn/Strobe, High cd, Red PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor Wall weatherproof back box Ceiling weatherproof back box Ceiling Horn/Strobes (contd.) PC4W 4-wire Horn/Strobe, Standard cd, White PC4WH 4-wire Horn/Strobe, High cd, White Ceiling Strobes SCR* Strobe, Standard cd, Red SCRH' Strobe, High cd, Red SCRI( Strobe, Standard cd, Red, Outdoor SG1HK Strobe, High cd, Red, Outdoor SCW Strobe, Standard cd, White SCWHt Strobe, High cd, White Horns HR Horn, Red HRK Horn, Red, Outdoor HW Horn, White Accessories BBS-2 Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt. Watt, White BBSC-2 Back Box Skirt. Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White I R-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White TRC-HS Trim Ring, Ceiling, Red TRCW-HS Trim Rino. Ceilino. White Notes: Add"-Pto model number for plain housing (noFlREmarking on cover), e.g., P2R-R f Add-SP'to model number fori4JEGOmarking on cover, e.g., P2R-SP tStandard Cdrefers to strobes that include 15,15/75,30,75,95,110, and 115 candela settIngs 'High cd refers to strobes that include 135,150,177, and 185 candela settings. All outdoor units ending in l(' include a weatherproof back box o Add-Wto model number for weatherproof replacement device (no back box included). "STEM 3825 Ohio Avenue. St. Charles, IL 60174 C7SYSt&flSflSOt Pctspedf5ali ssbjectshangewtnofle.vstemensor.conw ~Mrn Prock'a "•__$ SENSOR- Phone: 800-SENSOR2 Fax 630-377-6495 505-0395 n5.8/39.#2018 S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTiNG SERVICE LISTING No. 7125-1653:188 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix P' for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (40 Degrees C to +66 Degrees C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA.WBBW (Wall), SA-WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or -" recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division 0 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECHON OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE STING No. 7135-1653:189 Page 1 of I CATEGORY Audible Devices LISTEE System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish. Linhan'(systemsensor.com DESIGN: Models HR, HW Horns and CHR, CHW chimes. Intended for indoor use only unless otherwise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (40 Degrees C to +66 Degrees C) and are rated NEMA *4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SAWBBW (Wall), SA-WBBC (Ceiling) and *SA. IBBCW (Ceiling). Models CHR and CHW are intended for private mode use only. Suitable for wall or ceiling mount. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8— 17.5 or 16-33 VdcNFWR OSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. *Rev 12-01-05 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 *Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 01STING No. 7125-1653:186 Page 1 of I CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 x 1185 Fax (630) 377-7245 Trish.Linhartsystemsensor.com DESIGN: Synchronous type strobe lights, Models SR, SRH, SW, SW-CLR-ALERT, SWH, SCR, SCRH, SCW, SCW-CLR-ALERT* and SCWH followed by the suffix -P, -SP, -PG, or none. Intended for indoor use mounted on the wall or the ceiling. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 8-17.5 or 16-33 VDC/FWR Candela: 15,15/75,30,75,95, 110 c INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. OARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired application when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Refer to listee's Installation Instruction Manual for details. *Rev. 05-04-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division