Loading...
HomeMy WebLinkAbout6286 EL CAMINO REAL; ; FA070082; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA070082 6286 EL CAM INO Job Address: REAL Permit Type: FALARM Parcel No: 2131101500 Lot #: 0 Status: ISSUED Applied 11/15/2007 Approved: 11/19/2007 Reference No.: Issued: 11/19/2007 PC #: Inspector: Project Title: ASPIRATIONS DAYCARE CENTER 2 FIRE ALARM INSPECTIONS @ $65/EA Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: ASPIRATIONS INC C/O ALAN HElM 1966 CHERRYWOOD ST VISTA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 j 130 0 FAo-4<)o%?_ IFNFIRP _u_ FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS I it' Ii t' hecit ci Kit cd itti ippsus ii tulip! ,trtte 5'. till lilt' It fttlt 41(tlk hl'. ci'tiei'mid iititTattl' Ill ituice it hr tirtdtctittit lii st ncr or '.ttiiii ,iritl Iris Will/u this it' tn in suppiuri ii all ippltc5iii0n hr a hildititi peititti IS iii tic epicss utideistatidnig that lilt, ci test in n ",I% cItes es tile tn ncr ic coliiraeioi- ti tile 11 pioksiittial ii guicer or architect fiw sok respittisihil ii 11111 ctiinpi tance with said codes antI standards. including the building code or for any respotisihihy for cid icienctes. errors. omissions (it, negligence In these plaits wheihei' or not noted in this review. Date: '//6/'i Reviewer: RECOMMEND APPROVAl. 0 RECOMMEND APPROVAL AS NOTED ASPIRATIONS DAY CARE CENTER 6286 EL CAMINO REAL CARLSBAD CALIFORNIA FIRE ALARM SYSTEM APPROV, SUBMITTED EAR LS cEPARTMENT - ASPIRATIONS DAY CARE CENTER CARLSBAD, CALIFORNIA BILL OF MATERIALS NOTIFIER NFW2-100 FIRE ALARM CONTROL PANEL CSFM# 7165-0028:235 NOTIFIER NOT-BGI2LX ADDRESSABLE MANUAL PULL STATION CSFM# 7150-0028:199 NOTIFIER NP-100 ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR CSFM# 7272-0028.231 NOTIFIER NH-100 INTELLIGENT ADDRESSABLE THERMAL DETECTOR CSFM#72 70-0028:234 NOTIFIER NMM-100P ADDRESSABLE MONITOR MODULE CSFM# 7300-0028:230 WHEELOCK SERIES AS AUDIBLE STROBE APPLIANCE CSFM# 7125-0785:131 WHEELOCK SERIES RSS STROBES CSFM# 7125-0785:141 DN-7101 •A1-11O FireWarden.1 00.2(E) Intelligent Addressable FACP NOTIFIER with Built-In Communciator by Honeywell r . - GENERAL The Notifier FireWarden-100-2 (NFW2-100) is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter) all on one circuit board. This com- pact intelligent addressable control panel has an extensive list of powerful features. The SLC (Signaling Line Circuit) of the FireWarden-100-2 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an inci- dent and activate the notification circuits in under 10 seconds. With this improved polling, devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. (Consult the wire table on page 3 for specific installation instructions.) The FireWarden-100-2's quick-remove chassis protects the electronics during construction. The backbox can be installed allowing field wiring to be pulled. When construction is com- pleted, the electronics can be quickly installed with just two bolts. Available accessories include LED, graphic and LCD annunci- ators, and reverse polarity/city box transmitter. The panel is programmed through the FACP's keypad or via a standard PS-2 computer keyboard, which can be plugged directly into the printed circuit board. This permits easy typing of address labels and other programming information. NOTE: Unless otherwise specified, the terms Fire Wa rden- 100-2 is used in this document to refer to both the Fire Warden- 100-2 and the Fire Warden- 100-2E FACPs (Fire Alarm Control Panels). FEATURES On-board DACT. Four Class B or two Class A NAC circuits. Selectable strobe synchronization for System Sensor, Wheelock, and Gentex devices. Complies with UL 864 9th Edition requirements. Remote Acknowledge, Silence, Reset and Drill via address- able monitor modules. Up to 32 annunciators or remote annunciators via EIA- 485. EIA-232 printer/PC interface (variable baud rate) on main circuit board. Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. Detector sensitivity test capability (NFPA 72 compliant). History file with 1,000-event capacity. Maintenance alert warns when smoke detector dust accu- mulation is excessive. Automatic device type-code verification. One person audible or silent walk test with walk-test log and printout. Point trouble identification. Waterfiow (nonsilenceable) selection per monitor point. System alarm verification selection per detector point. PAS Positive Alarm Sequence) and presignal delay per point (NFPA 72 compliant). NOTE: Only defectors may participate in PAS. SLC LOOP: SLC can be configured for NFPA Style 4, 6, or 7 operation. SLC supports up to 198 addressable devices per loop (99 detectors and 99 monitor, control, or relay modules). SLC loop maximum length 10,000 ft. (3,000 rn). See wire table on page 3. NOTIFICATION APPLIANCE CIRCUITS (NACS): Four onboard NACs with additional NAC capability using output control modules (NC-100). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. Selectable strobe synchronization per NAC. 2.5 amps maximum per each NAC circuit. NOTE: Maximum or total 24VDC system power shared between all NAC circuits and auxiliary power outputs is 3.6 amps. (System power ir.creases to 6.6 amps with optional XRM-24 transformer.) PROGRAMMING AND SOFTWARE: Autoprogram (learn mode) reduces installation time. Custom English labels (per point) may be manually entered or selected from an internal library file. Two programmable Form-C relay outputs. 99 scttware zones. Continuous fire protection during online programming at the front panel. Program Check automatically catches common errors not linked to any zone or input point. DN-71 01 • 08/28/06 - Page 1 014 USER INTERFACE LED INDICATORS AC POWER (green) FIRE ALARM (red) SUPERVISORY (yellow) ALARM SILENCED (yellow) SYSTEM TROUBLE (yellow) MAINTENANCE/PRESIGNAL (yellow) DISABLED (yellow) BATTERY FAULT (yellow) GROUND FAULT (yellow) KEYPAD CONTROLS ACKNOWLEDGE/STEP ALARM SILENCE DRILL SYSTEM RESET (lamp test) 16-key alpha-numeric pad (similar to telephone keypad) 4 cursor keys ENTER ORDERING OPTIONS NFW2-100(E): 198-point addressable Fire Alarm Control Panel, one SLC loop. Includes 80-character LCD display, sin- gle printed circuit board mounted on chassis, and cabinet. 4XTM Reverse Polarity Transmitter Module: Provides supervised output for local energy municipal box transmitter, alarm, and trouble. DP-96928: Optional dress panel for Fire Warden- 100-2. TR-CE-B: Trim Ring for semi-flush mounting. BB-26: Battery backbox, holds up to two 26 AH batteries and CHG-75. NFS-LBB: Battery box, houses two 55 AH batteries. CHG-75: Battery charger for lead-acid batteries with a rating of 25 to 75 AH. CHG-120: Remote battery charging system for lead-acid bat- teries with a rating of 55 to 120 AH. Requires additional NFS- LBB for mounting. NOTE: CHG- 120 or CHG-75 required for batteries larger than I8AH. BAT Series: Batteries, see data sheet DN-6933. XRM-24(E): Optional transformer. Increases system power to 6.6 amps. Use XRM-24E with FireWarden-100-2E. PRT/PK-CABLE: Cable printer/personal computer interface cable. PRN-6: UL listed compatible event printer. Uses tractor-fed paper. COMPATIBLE ANNUNCIATORS ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. ACM Annunciator Series: LED-type fire annunciators capa- ble of providing up to 99 software zones of annunciation. Avail- able in increments of 16 or 32 points to meet a variety of applications. LDM Graphic Series: Lamp Driver Module series for use with custom graphic annunciators. FDU-80 (Liquid Crystal Display) point annunciator: 80-character, backlit LCD-type fire annunciators capable of displaying English-language text. NOTE: For more information on Compatible Annunciators for use with the Fire Warden- 100-2, see the following data sheets (docu- ment numbers) ACM-8R (DN-3558), ACS/ACM Series (DN-0524), LDM Series (DN-0551), FDU-80 (DN-6820). Page 2 of 4— DN-7101 • 08/28/06 COMPATIBLE ADDRESSABLE DEVICES All feature a polling LED and rotary switches for addressing. NI-100: Addressable low-profile ionization smoke detector. NP-100: Addressable low-profile photoelectric smoke detec- tor. NP-lOOT: Addressable low-profile photoelectric smoke detec- tor with thermal sensor. NH-100: Fast-response, low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate- of-rise option. ND-100: Photoelectric low-flow duct smoke detector. ND-100R: Photoelectric low-flow duct smoke detector with relay option. NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0' (10.16 cm.) box. Includes plastic cover plate and end-of- line resistor. Module may be configured for either a Style B (Class B) or Style D (Class A) bC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B (Class B) only lDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option. Connects with wire pigtails. May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power. Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style VIZ (Class B/A) zone of supervised polarized Notification Appli- ances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification Appliance Circuit option requires external 24 VDC to power notification appliances. NC-1100R: Addressable relay module containing two isolated sets of Form-C contacts, which operate as a DPDT switch. Mounts directly to a 4.0" (10.16 cm.) box, surface mount using the SMB500. NOT-BG12LX: Addressable manual pull station with interface module mounted inside. N100-ISO: Fault Isolator Module. SMB500: Used to mount all modules except the NMM-100P. NOTE: For more information on Compatible Addressable Devices for use with the Fire Warden-100-2, see the following data sheets (document numbers): N100-ISO (DN-6994), NP- 100/NP- lOOT (DN-6995), NI-100 (DN-6996), NH- 100/NH- IOOR (DN-6997), ND- 100/ND- IOOR (DN-7006), NMM- 100/NMM- 100P/NDM- 100/NZM- 100 (DN-6999), NC- 100/NC-100R (DN-7000), and NOT-BG I2LX (DN-7001). WIRING REQUIREMENTS While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical inter- ference. Wire size should be no smaller than 18 AWG (0.78 mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Use the table below to determine the specific wiring requirements for the SLC. SLC Wire Requirements Distance in Feet (m) Wire Size Wire Type Non-Plenum (FPLR). Genesis 4315, Belden 5020UL Twisted-pair, unshielded 10,000 feet (3,048 m) 12 AWG (3.31 mm2) Plenum (FPLP): Genesis 4515, Belden 6020UL Non-Plenum (FPLR): Twisted-pair, unshielded 8,000 feet (2,438 m) 14 AWG (2.08 mm2) Genesis 4313, Belden 5120UL Plenum (FPLP): Genesis 4513, Belden 6120UL Non-Plenum (FPLR): Twisted-pair, unshielded 4,875 feet (1,486 m) 16 AWG (1.31 mm2) Genesis 4311, Belden 5220UL Plenum (FPLP): Genesis 4511, Belden 6220UL Non-Plenum (FPLR): Twisted-pair, unshielded 3,225 feet (983 m) 18 AWG (0.821 mm2) Genesis 4306, Belden 5320UL Plenum (FPLP): Genesis 4506, Belden 6320UL FireWarden-100-2 Wire Requirements DN-7101 • 08/28/06 -Page 3 014 SYSTEM SPECIFICATIONS All SYSTEM CAPACITY Intelligent Signalling Line Circuits.......................................1 Addressable device capacity ..........................................198 Programmable software zones.........................................99 Annunciators ....................................................................32 ELECTRICAL SPECIFICATIONS AC Power: FireWarden-100-2: 120 VAC, 60 Hz, 3.0 amps. FireWarden-100-2(E): 240 VAC, 50 Hz, 1.5 amps. Wire size: minimum 14 AWG (2.00 mm2) with 600 V insulation. Battery: Two 12 V 18AH lead-acid batteries. Battery charger capacity: 7 - 18 AH. FireWarden-100-2 cabinet holds maxi- mum of two 18 AH batteries. Communication Loop: Supervised and power-limited. Notification Appliance Circuits: Each terminal block pro- vides connections for two Style V (Class B) or one Style Z (Class A) for a total of four Style V (Class B) or two Style Z (Class A) NACs. Maximum signaling current per circuit: 2.5 amps. End-of-Line Resistor: 4.7K ohm, 1/2 watt (P/N 71252 UL listed) for Style V (Class B) NAC. Refer to Notifier Device Compatibility Document for listed compatible devices. Two Programmable Relays and One Fixed Trouble Relay: Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive). Form-C relays. Special Application Power (24 VDC Nominal): Jumper selectable (JP4) for conversion to resettable power output. Up to 0.5 amps total DC current available from each output. Power-limited. Four-Wire Resettable Special Application Smoke Detector Power (24 VDC nominal): Up to 0.5 amps for powering four- wire smoke detectors. Power-limited. Refer to Notifier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization output. Nominal special application power: 24 VDC. Maximum current: 40 mA. End-of-Line Resistor: 4.7K ohm. Output linked to NAC 1 control. Supervised and power-limited. Telephone Interface: Requires dedicated business tele- phone number with a minimum of 7 volts DC. Obtain dedicated phone line directly from your local phone company. Do not use shared phone lines or PBX (digital) type phone line extensions. CABINET SPECIFICATIONS Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.12' (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) wide x 5.20" (13.34 cm.) deep. Trim Ring (TR-CE-B): 22.00' (55.88 cm.) high x 19.65" (49.91 cm.) wide. SHIPPING SPECIFICATIONS Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 30F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 270C160 - 80°F. NFPA STANDARDS The FireWarden-100-2 complies with the following NFPA 72 Fire Alarm Systems requirements: - LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). - AUXILIARY (Automatic, Manual and Waterflow) (requires 4XTM). - REMOTE STATION (Automatic, Manual and Waterflow) (Where a DACT is not accepted, the alarm trouble and supervisory relays may be connected to UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble, 4XTM is required.) - PROPRIETARY (Automatic, Manual and Waterflow). - CENTRAL STATION (Automatic, Manual and Waterflow, and Sprinkler Supervised). - AUTO DETECTOR SELF TEST AGENCY LISTINGS AND APPROVALS The listings and approvals below apply to the basic FireWar- den-i 00-2 control panel. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 CSFM: 7165-0028:235 MEA: 120-06-E, Volume 2 Microsoft® and Windows® are registered trademarks of the Microsoft Corpo- ration. 02006 by Honeywell international Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ENGINEERING & MANUFACTURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A, For more information, contact Notifier. Phone: (203)484-7161, FAX: (203) 484.7118. www.notifier.com Page 4 of 4 - DN-71 01 • 08/28/06 CALIF ORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0028:235 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models Fire Warden 100 and *Fire Warden 100-2 addressable control units. Local, auxiliary, remote station, central station and proprietary (protected premise). Refer to listee's data sheet for detailed product description, operational considerations and required/optional accessories. When required, accessories shall be CSFM listed. RATING: 120 VAC, 60 Hz, 2.06 A Primary, 24 VDC Secondary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as an addressable fire alarm control panel for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. This control unit can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. XLF: 7165-0075:208 *Rev/Rece 06-27-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager U'll NOTIFIER CR by Honeywell GENERAL The NOTIFIER NOT-BG12LX is a state-of-the-art, dual- action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for NOTIFIER's addressable FireWarden-100 fire alarm control panel. Because the NOT-BG12LX is addres- sable, the control panel can display the exact location of the activated manual pull station. This leads fire service personnel quickly to the location of the alarm. FEATURES Aesthetically pleasing, highly visible, dual-action design. Meets ADA 5 lb. maximum pull force. Easily operated (dual-action). Attractive shape and textured finish. Mounts, semi-flush, to a standard single-gang (2.125' 15.398 cm] minimum depth), double-gang, or 4.0" (10.16 cm) square electrical box. When the handle latches in down position, the word AC- TIVATED" appears at the top of the handle in bright yel- low to clearly indicate the station has been operated. Key/lock reset; needs only a 1/4-turn to lock/unlock. Includes Braille text on station handle. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.1 mm2 wire). Optional trim ring (BG-TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Maintenance personnel can open station (for inspection and testing) without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes red in normal operation and latches on steady red when in alarm. ENGINEERING SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored LEXAN® (or polycarbonate equivalent) with clearly visible operating instructions pro- vided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b 0 or SB-I/O; or semi-flush mount- ing on a standard single-gang, double-gang, or 4.0" (10.16 LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. June 15, 2005 DN-7001 • A1-380 NOT-BG1 2LX Addressable Manual Pull Station for FireWarden-1 00 Section: Addressable Patented, U.S. Patent No. D428,351; 6,380,846 U.S. Patent Pending: 0916 86,286 MEA California State Fire 67-02-E Vol. IV Marshal 7150-0028:199 <:*> LISTED - APPROVED The NOT-BG12LX Addressable Manual Pull Station cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the control panel SLC loops. The manual station shall, on com- mand from the control panel, send data to the panel repre- senting the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. ELECTRICAL SPECIFICATIONS Normal operating voltage: 24 VDC, Maximum SLC loop voltage: 28.0 VDC, product information up-to-date and accurate. We cannot cover au specific applications or I ISO go 01 This document is not intended to be used for installation purposes. We try to keep our I anticipate all requirements. At; specifications are subject to change without notice. I For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: 1203i 484-7118 I i i •i NOTI Ft ER" ENGINERINC & MANUFACTURING by Honeywell 12 Clintonville Road, Northtord, Connecticut 06472 QUALITY SYSTEMS DN-7001 06/15/05 - Page t of Maximum SLC loop current: 230 pA. INSTALLATION The NOT-BG12LX can be semi-flush mounted into a single- gang, double-gang, or standard 4.0' (10.16 cm) square elec- trical outlet box, or surface mounted to the Model SB-10 or SB-I/O surface backbox. If the NOT-BG12LX is semi-flush mounted, then the optional trim ring (BG-TR) may be used. The BG-TR is usually needed for semi-flush mounting with 4.0" (10.16 cm) or double-gang boxes (not with single-gang boxes). CONSTRUCTION ) . ••.: a _1 2 Back of station without door. Shell, door, and handle are molded of durable LEXAN® (or polycarbonate equivalent) with a textured finish. OPERATION Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTIVATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bot- tom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action re- sets the handle; closing the door automatically resets the switch. Manual stations connect with two wires to one of the control panel SLC loops. Each manual station, on command from the control panel, sends data to the panel representing the state of the pull station switch. Two rotary decimal switches allow address settings (01-99). PRODUCT LINE INFORMATION NOT-BG12LX Dual-action addressable pull station. Includes key lock/reset feature. SB-b 0 Surface backbox. SB-I/O Surface indoor/outdoor backbox. BG-TR Optional trim ring 7 0 Detail of BREAKAWAY TAB* 11 14 15 1 01 2 3 aMñ 'I TERMINAL CONNECTIONS 1 SLC 2 SLC (+) Cover open to show easy access to miniature monitor module, rotary switch, and UL label. Page 2012 - DN-7001- 06/1505 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:199 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Notifier, One Fire-Lite Place, Northford CT 06472-1653 Contact: Larry Flood (203) 484*7161 FAX (203) 484-7309 DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBC- 12-LO, NBG-12LOB, NBG-12W, NBG-12LW, NBG-12NC, NBG-12WP, NBG-12LWP, NBC- 12L, NBG-12LX, NBG-12LA, NBG-12PS, NBG-12LSP, NBG-12LPS, NBG-12LPSP, NBC- 12SP, NOT-BG12LX, and *NBG12LxsP fire alarm pull boxes. All units except Model NBC- 12S are dual action pull stations. Models NBG-12LR and NBG-12LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-12WP, NBG-12LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG- 12LAOB and NBG-12L0B are intended for outdoor use when installed with Models WBB, SB- I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. Rev 1-06-2006 jew This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the ted resLilts and/or other data but does not make an independent verification of any claims. This listing is not an endorsecent or recommendation of the item listed. This listing should not be used to verify correct operational requirements or inslatlaton jI criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dote IsduOd: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager Juno 15, 2005 ON-6995 A1-310 NOTIFIER by Honeywell GEN ERAL The NP-100 and NP-100T addressable, low-profile plug- in Photoelectric detectors use a state-of-the-art photoelec- tric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden-100 Addressable Fire Alarm Con- trot Panel (FACP). The NP-100T adds thermal sensors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (PIN RA400Z). FEATURES SLC loop: Two-wire loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. Architecture: Unique single-source, dual-chamber design to respond quickly and dependably to a broad range of fires. Sleek, low-profile design. Integral communications and built-in type identification. Built-in tamper-resistant feature. Removable cover and insect-resistant screen for simple field cleaning. Operation: Withstands air velocities up to 4,000 feet-per-minute (20 mlsec.) without triggering a false alarm. Factory preset at 1.5% nominal sensitivity for panel alarm threshold level. Visible LED "blinks" when the unit is addressed (com- municating with the fire panel) and latches on in alarm. Mechanicals: Sealed against back pressure. Direct surface mounting or electrical box mounting. Mounts to. single-gang box. 3.5' (8.89 cm)or 4 0" 110.15 cm) octagonal box, or 4.0" (10.15 cm) square electrical box (using a plaster ring - Included). Other system features: Fully coated circuit boards and superior RF/transieni NP-100 and NP-lOOT Addressable Photoelectric Detectors Section: Addressable liforni Ca State Fir <*> Marshal \/ 7272-0028:231 APPROVED LISTED Sills MARYLAND MEA State Fire Marshal 243-02-E Vol II Permit # 2173 NP-IOU i with B71OLP base 934pho1 jpg NP-IOOTwith B71OLPbase ' 6935ph01.jpr protection. 94-VO plastic flammability rating. Low standby current. Options: Remote LED output connection (PIN RA400Z). SPECIFICATIONS Voltage range: 15-32 VDC (peak). Standby current: 300 pA © 24 VDC. LED current: 6.5 mA © 24 VDC (latched "ON"(. AirVelocity: 4,000 ft/mm. (20 m/sec.) maximum. Diameter: 6.1' (15.5 cm) installed in B710LP base. Height: 21" 15.33 cm installed in B710LP base. Weight: 3.6 ox. (102 g). Operating temperature range: for NP-100: 0"C to 49 (32"F to 120'F(: for NP-lOOT. Q to 38°C (32F to 100 F), Temperature: 0°C - 490 (32°F — 1207). Relative humidity: 1001. — 93%, non-condensing. Thir ':c, jre'n 5 'sci ias.:'"j 0 ira .; --iahr::r,"r p.Jrf:'D'rr '1)5 c ' i''a sir 'd'ji 1.l,r ,'h".,'',,5.t".. "a'. arrirsie .°Je cari°'ri c'Der aD rpar''r apsi liii .51,5 'Dr ar',I,clpair' all r5o''5r'r'ri AD spesiirsrriisr's are sui;105' '5 'a's'D',,'.'.i"'Dt.I r.'DI,c For 'store niurm-Olios, oo'rOr.: tiOl'iFIER. Phone: 202) 8'716 FAX. '202, i047110 i 71; ' iit1 (l NOT I F I E R' ENCINEERINC g MANUFACTURING by Honeywell 12 Ohrrto's'j)ie Road, 110r1h10rd, Con'secircui 06172 QUALITY SYSTEMS 011-6995 06/15/05 — Page 1 0'? APPLICATIONS Use Photoelectric detectors in life-safety applications to provide a broad range of fi re-sensing capability, espe- cially where smoldering tires are anticipated. Ionization detectors are often better than photoelectric detectors at sensing fast, flaming fires. CONSTRUCTION These detectors are constructed of off-white LEXAN®. NP-100(T) plug-in, low-profile smoke detectors are de- signed to commercial standards and otter an attractive appearance. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. INSTALLATION NP-100(T) plug-in detectors use a detachable mounting base to simplify installation, service and maintenance. Mount base on box which is at least 1.5 inches (3.81 cm) deep. Suitable boxes include: 4.0" (10.16 cm) square box with plaster ring. 4.0' (10.16 cm) octagonal box. 3.5" (8.89 cm) octagonal box. Single-gang box. NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring "T- taps" or branches are permitted for Style 4 (Class B) wiring. ['I•j4•1'i I I.]' Each NP-100(T) uses one of 99 possible addresses on the FireWarden-100 Signaling Line Circuit (SLC). It re- sponds to regular polls from the system and reports its type and status. The NP-100(T) addressable photoelectric sensor's unique unipolar chamber responds quickly and uniformly to a broad range of smoke conditions and can withstand wind gusts up to 4,000 feet-per-minute (20 rn/sec.) with- out sending an alarm level signal. Because of its unipo- far chamber, the NP-100(T) is approximately two times more responsive than most photoelectric sensors. This makes it a more stable detector. DETECTOR SENSITIVITY TEST Each detector can have its sensitivity tested (required per NFPA 72, Chapter 7 on Inspection, Testing and Mainte- nance) when installed/connected to a FireWarden-100 addressable fire alarm control panel. The results of the sensitivity test can be printed off the FireWarden-1 00 for record keeptng. PRODUCT LINE INFORMATION NP-100 Addressable photoelectric detector: B71OLP base included.' NP-100T Same as NP-100 but with thermal element: B71OLP base included: RA400Z Remote LED. Mounts to a single-gang box. B71OLP Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4,0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224RB Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plas- ter ring, 4,0" (10,16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1 Plug-in System Sensor isolator detector base. Maximum 25 devices between isola- tor bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0" (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). Prior to 03/28/05, the 8710LP base was sold separately. Page 2 of 2 - DH-6995 0605.05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0028:231 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Notifier, One Fire-Lite Place, Northford, 0106472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NP-100 and NP-lOOT photoelectric type smoke detectors. Model NP-lOOT has a 135°F supplement integral heat sensor which only assists in a fire situation. The purpose of this thermal circuitry is to increase the sensitivity of the detector. This thermal circuitry is NOT approved for use as a heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24VD0 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detector for use with separately listed compatible fire alarm control units. All units are suitable for installation inside air duct with a maximum air velocity of 4000 fpm. Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires, which smolder for hours before bursting into flames. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires, which consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-0075:194 11 .Q3QQ4 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has re lie nd the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not he used to verify correct operational requirements or inslallation criteria Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dote lEsued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager June 15.2005 DN-6997•A1-320 I ® NH-1 00 Series I NOTIFIER Intelligent Addressable Thermal I by Honeywell (Heat) Detectors for FireWarden-100 I Section: Addressable I GENERAL The NOTIFIER NH-100 Series thermal detectors are ad- dressable sensors that use a state-of-the-art thermistor sensing circuit for fast response. These sensors are de- signed to provide open-area protection and are intended for use with the FireWarden-1 00 Fire Alarm Control Panel (FACP). Both the NH-100 and NH-i OOR sensors provide fixed tem- perature alarm detection at 135°F/57°C. The NH-100R sensor responds to rate-of-rise conditions of greater than 15°F18.31C per minute. These thermal detectors provide cost effective, addressable property protection in a variety of applications. Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional accessory (P/N RA400Z). FEATURES SL loop: Two-wire SLC loop connection. Unit uses base for wiring. Addressing: Addressable by device. Direct Decade 01 - 99 (FireWarden-100) entry of ad- dress. Architecture: Sleek, low-profile, stylish design. State-of-the-art thermistor technology for fast response. Integral communications and built-in device-type iden- tification. Built-in tamper resistant feature. Built-in functional test switch activated by external mag- net. Operation: Factory preset at 135°F (57°C). Rate-of-rise model (NH-100R), 15°F (8.3°C) per minute. 360°-field viewing angle of the visual alarm indicators (two bicolor LEDs). LEDs blink green in Normal condi- tion and turn on steady red in Alarm. Visible LEDs "blink" every time the unit is addressed. Mechanicals: Sealed against back pressure. SEMS screws for wiring of the separate base. Designed for direct-surface or electrical-box mounting. Plugs into separate base for ease of installation and maintenance. c:i MEA 387-02-E Vol. II LISTED S747 <9> APPROVED California State Fire Marshal 7270-0028:234 NH-100 with B71OLP base Separate base allows interchange of photoelectric, ion- ization and thermal sensors. Other system features: Remote test feature from the panel. Walk test with address display. Low standby current. 94-5V plastic flammability rating. Options: Remote LED output connection to optional RA400Z re- mote LED annunciator. Recessed (RMK400) or surface (SMK400) base mount- ing kits. SPECIFICATIONS Diameter: 6.1" (15.5 cm) installed in B71OLP. Height: 2.1" (5.33 cm). Weight: 4.8 oz. (137 g). Installation temperature: —4°F to 100°F (-20°C to 38°C). Humidity range: 10% to 93% relative humidity (noncon- This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IS09001 For more information, contact NOTIFIER. Phone: (203) 484.7161 FAX: (203) 484-7118 NOT I F I E R° ENGINEERING & MANUFACTURING by Honeywell 12 Clintonville Road, Norlhford, Connecticut 06472 QUALITY SYSTEMS DN-6997 • 06/15/05 - Page 1 012 densing). Voltage range: 15 to 32 VDC peak. Standby current: 300 lJA @ 24 VDC (one communica- tion every five seconds with LED blink enabled). LED current: 6.5 mA @ 24 VDC. Mounting: B71OLP flanged base, sold separately. Fixed-temperature setpoint: 135°F (57C). Rate-of-rise detection: responds to greater than 15°F! 8.3°C per minute. INSTALLATION NH-100 Series plug-in intelligent thermal detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on box that is at least 1.5 (3.81 cm) deep. Suitable boxes include: 4.0 (10.16 cm) square box. 3.5' (8.89 cm) or 4.0° (10.16 cm) octagonal box. Single-gang box (except relay or isolator base). NOTE: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring '7- taps" or branches are permitted for Style 4 (Class "B") wiring only. APPLICATIONS Use thermal detectors for protection of property. CONSTRUCTION These detectors are constructed of off-white Bayblend®. The NH-100 Series plug-in intelligent thermal detectors are designed to commercial standards and offer an at- tractive appearance. Baybtend® is registered trademark of Bayer Corporation. OPERATION Each NH-100 Series detector uses one of 99 (FireWarden-100) possible addresses on a control panel SLC loop. It responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when com- manded by the panel. The NH-100 Series offers features and performance that represent the latest in thermal de- tector technology. PRODUCT LINE INFORMATION NH-100 Intelligent thermal sensor; B71OLP base in- cluded.* NH-100R Same as NH-100 with rate-of-rise feature; B71OLP base included.* RA400Z Remote LED. Mounts to a single-gang box. B71OLP Plug-in detector base. Dimensions: 6.1" (15.5 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0 (10.16 cm) octagonal box, 3.5" (8.89 cm) octagonal box, or single-gang box. All mounting boxes have a minimum depth of 1.5' (3.81 cm). M02-04-00 Test magnet B224RB Plug-in System Sensor relay detector base. Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5" (8.89 cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B224B1 Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). Diameter: 6.2" (15.75 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring, 4.0" (10.16 cm) octagonal box, or 3.5(8.89cm) octagonal box. All mounting boxes have a minimum depth of 1.5" (3.81 cm). B501BH Plug-in System Sensor sounder detector base. Diameter: 6.0' (15.24 cm). Mounting: 4.0" (10.16 cm) square box with or without plaster ring. Mounting box has a minimum depth of 1.5" (3.81 cm). *Prior to 03/28/05, the 8710LP base was sold separately Page 2 of 2 - DN-6997 - 06/15/05 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:234 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Notifier, One Fire-Lite Place, Northford, CT 06472-1653 Contact: Lawrence Flood (203) 484-1200 FAX (203) 484-7309 DESIGN: Models NH-100, (fixed temperature) and NH-100R rate-of-rise with fixed temperature heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: NH-100 135° F fixed temperature NH-i OOR 1350 F fixed temperature and 150 F rate-of-rise INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-0075:195 11-03-2004 o This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager NOTIFIER by Honeywell June 15. 2005 DN-6999 • A1-350 Addressable Monitor Modules for the FireWarden-100: NMM-1 00, NMM-I OOP, NZM-1 00, NDM-1 00 Section: Addressable GENERAL Four different monitor modules are available for NOTIFIER's FireWarden-100 intelligent fire alarm control panels to sLot a variety of applications. Monitor modules are used to supervise a circuit of dry-contact input de- vices, such as conventional heat detectors and pull sta- tions, or monitor and power a circuit of two-wire smoke detectors (NZM-100). NMM-1 00 -The NMM- 100 Monitor Module is a standard- sized module (typically mounts to a 4.0" [10.16 cm] square box) that supervises either a Class A (Style D) or Class B (Style B) circuit of dry-contact input devices. NMFv1-1 OOP - The NMM-1 OOP is a Miniature Monitor Mod- ule (a mere 13 (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) 0) used to supervise a Class B (Style B) cir- cuit. Its compact design allows the NMM-100P to be mounted in a single-gang box behind the device it is moni- torin g. NZM-100 - The NZM-100 Interface Module is a stan- dard-sized module used to monitor and supervise com- patible two-wire, 24 volt, smoke detectors on a Class A (Style D) or Class B (Style B) circuit. NDM-1 00 The NDM-1 00 Dual Monitor Module is a stan- dard-sized module (typically mounts to a 4.0 (10.16 cm) square box) that supervises two Class B (Style B) circuits of dry-contact input devices. NMM-100 MONITOR MODULE Built-in type identification automatically identifies this de- vice as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMFIRFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct Decade 01 - 99 (FireWarden-1 00) entry of ad- dress. LED flashes red during normal operation and latches on steady to indicate alarm. The NMM-100 Monitor Module is intended for use in intel- ligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire Class A or Class B fault-tolerant Initiating Device Circuit (IDC) for normally- open-contact fire alarm and supervisory devices. NMM-100 Applications - Use to monitor a zone of four-wire smoke cletoctors, manual fire alarm pull stations, walerliow devices, or other normally-open dry-contact alarm activation deviccu, May also be used to monitor normally-open sLipervisory devices vnth special supervi- sory indication at the control panel. MnnitorerJ circuit may be ovired as an NFPA Style B (Class 8) or. Style 0 (Class Di Initiating Device C;rcui A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is re- .ij California State Fire UI MEA Marshal 72-01-E Vol. II 11 7300-0028:230 LISTED - - (except NDM-100) (except NOM-100) S635 < > APPROVED C 9 6789, 0 8 1 D 213 7 TE14S101514 2 e78 9 6 4 3 5 2' 4 ONES LOOP ADDRESS NMM-100 and NZM-100 quired for supervision of the Style D circuit. Maximum IDC resistance is 1,500 ohms. NMM-100 Operation - Each NMM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop, It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NMM-100 Specifications Nominal operating voltage: 15 to 32 VDC Maximum current draw: 5.1 mA (LED on). Average operating current: 400 i,jA (LED flashing) EOL resistance: '17K ohms. Temperature range: 32'F to 120F (0'C to 49'C. Humidity range: 00. to 93'o noncondei-ising. Dimensions: 4.5" 111.43 cm) high x 4.0" (10.16 cml widex 1,25" (".175 cm deep Mounts to a 4,0" (10 16 cm) sqLiurn x 2.125" (5.398 cm) deep box. This 000UrTOri .5 -n; intcnd,od In loT j'2 ic' eLialialTOT purposes. We iry In keNo cur DrOCUTI infr"rair, 5D-io-dCU0 lr".ij accurOtS. 'i-IC cc r,nct co-ocr 011 OFECi'S epolcat'ons 0 erLope :e Cli mg': 0rr,e-i, a : speo'oaIo's Cr's sJi;yooi In cLang's 71:i°rc0 T'0Cc For rrrorr oo,-'noi NOTIFiER. Pso ce' 203 48.'-716i PAY.: i2O3 45U.7110 i -uei t) NOTI F E R' INGINFERING g MNUfcTlJRlNg by Honeywell 2 Cin0".'fi1C. Road. :'.ir5Irrj Connect0u 06472 Q UALITY SYSTEMS ON-6999 06/15/05 - Page 1 oI:i ThTf ['i']Jl Built-in type identification automatically identifies this de- vice as a monitor module to the FireWarden-i 00. Powered directly by two-wire SLC Loop. No additional power required. High noise (EMFRFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address (01-99 for FireiNarden-100). The NMM-100P Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The NMM-100P is intended for use in in- telligent, two-wire systems where the individual address of each module is selected using rotary switches. It pro- vides a two-wire initiating device circuit for normally-open- contact fire alarm and security devices. 1415 0 1 ADDRESS 0 1 12 3L__..______Jt iii (y 0P1 (4 ,t 14 1O Y5 TENS ONES NMM-1001112 Applications - Use to monitor a single device or a zone of tour-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact devices. May also be used to monitor nor- mally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit/device is wired as an NFPA Style B (Class B) Initiating Device Cir- cuit. A 47K ohm End-of-Line Resistor (provided) terminates the circuit. N MM-lOOP Operation - Each NMM-100P uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (lDC). NMM-100P Specifications Nominal operating voltage: 15 to 32 VDC. Average operating current: 375 pA maxinlurn. EOL resistance: 47K ohms. Temperature range: 32F to 120CF (OC to 49C). Humidity range: 10% to 93 noricoridensinq. Dimensions: 1.3 (3 .302 cm) high x 2.75 (6 985 cm) vide x 0.5 (1,270 Cill) deep Wire length: 6.0 (15.24 cm) mninimuni. Pnrje 2 ci 3— Elf J-69-J9 05. 15.05 HZM-100 INTERFACE MODULE Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power soLirce (resettabte). High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address (01-99 for FireWarden-100). LED flashes during normal operation, LED latches steady to indicate alarm on command from control panel. The NZM-100 Interface Module is intended for use in in- telligent, addressable systems, where the individual ad- dress of each module is selected using built-in rotary switches. This module allows intelligent panels to inter- face and monitor two-wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one lull zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL-com- patible with the module. NZM-100 Applications - Use the NZM-100 to moni- tor a zone of two-wire smoke detectors. The monitored cir- cuit may be wired as an NFPA Style B (Class B) or Style 0 (Class A) Initiating Device Circuit. A 3.9 K ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 ohms). Install ELR across terminals 8 and 9 for Style D application. NZM-100 Operation - Each NZM-100 uses one of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (100). A flashing LED indicates that the module is in communication with the con- trol panel. The LED latches steady on alarm (subject to current limitations on the loop). NZM-100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 270 pA (LED flashing). EOL resistance: 3.9K ohms. External supply voltage (between Terminals T3 and T4): DC voltage: 18 to 28 volts power limited. Ripple voltage: 0.1 VAMS maximum. Current: 90 mA per module maximum. Requires regulated, resettable 24 VDC power. Temperature range: 32CF to 120F (0'C to 49°C). Humidity range: 101% to 93% noncondensing. Dimensions: 4.5 (11.43 cm) high x 4.0" (10.16 cm) wide x 1.25 (3.175 cm) deep. Mounts to a 4.0 (10 16 cm) square x 2.125 (5.398 cm) deep box. ct. O LU 0 _J INSTALLATION NMM-100, NZM-100, and NDM-100 modules mount di- rectly to a standard 4.0' (10.16 cm) square, 2.125' (5,398 cm) deep, electrical box: They may also be mounted to the SMB500 surface-mount box. Mounting hardware and in- stallation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regulations. These modules are intended for power- limited wiring only. The NMM-100P module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordinances and regulations. ARCH ITECTS'/ENGINEERS' SPECIFICATIONS Specifications of these and all NOTIFIER products are available from NOTIFIER. PRODUCT LINE INFORMATION NMM-100 Monitor module. NMM-100P Mini monitor module, NZM-100 Two-wire detector monitor module. NOM-100 Dual monitor module, SMB500 Optional surface-mount backbox. t I n ....... u t'T ' H I fv MOUNTING DIAGRAMS For standard-sized - modules -. DN-6999 '06/1 5/05 - Page 3';ll Built-in type identification automatically identities this de- vice as two monitor modules to the control panel. Powered directly by the two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of Wiring. Direct-dial entry of address 01 - 99 (FireWarden-100) uses two addresses per module. LED flashes red during normal operation and latches on steady red to indicate alarm. The NDM-100 Dual Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides two independent two-wire fault-toler- ant Initiating Device Circuits (lDCs) at two separate, con- seciitive addresses. It is capable of monitoring normally open-contact fire alarm and supervisory devices, or either normally open or normally closed devices for non-fire ap- plications. NOM-100 Applications - Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull sta- tions, watertlow devices, or other normally-open dry-con- tact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervi- sory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) Initiating Device Circuit. The 47K ohm End-of-Line Resistors (provided) terminate the Style B circuit. Maximum IDC resistance is 1,500 ohms. NOM-100 Operation - Each NDM-100 uses two of 99 (FireWarden-100) available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/ short) of its Initiating Device Circuit (IC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limitations on the loop). NDM.100 Specifications Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Average operating current: 750 pA (LED flashing). EOL resistance: 47K ohms. Maximum IDC wire resistance: 1,500 ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 935/0 noncondensing. Dimensions: 4.5" (11.43 cm) high x 40" (10.16 cm) nude x 1.25" (3.175 cm) deep. Mounts to a 4.0" (10.16 cm) square x 2.125" (5.398 cm) deep box. Accessories: SMB500 electrical box. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:230 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Notifier, 12 Clintonville Rd, Northiord CT 06472 Contact: Lawrence Flood (203) 484-1200 Fax (203) 484-7309 DESIGN: Models NMM-100P, NMM-100, and NZM-100 monitor modules; Models NC-100R and NC-100 control modules. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. IN 4 a bill 10-20-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results (j) and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or inslallation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Dote Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager 00 COOPER Wheelock Series AS Audible Strobe Appliances and Series AH A uC3,clibl4 • B. SERIES AS SERIES AH Description The Wheelock patented 2-wire Series AS Audible Strobe Appliances and Series AH Audibles offer more features with low current draw. Strobe options for wall mount models include 1575cd or the Wheelock patented MCW multi-candela wall strobes with field selectable candela settings of 15/30/75/110cd, or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models incorporate Wheelocks patented MCC multi-candela ceiling strobe with field selectable intensities of 15/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. The audible provides a selectable choice of either a continuous horn or temporal pattern (Code 3) when constant voltage from a Fire Alarm Panel (FACP) is applied. Each tone has 3 dBA settings to choose from. When used with the Wheelock Series SM or DSM Sync Module or Wheelock PS-24-8MC Power Supplies with Patented Sync Protocol, synchronization of the continuous horn tone provides the temporaF( ode 3) tone (mandated by NFPA 72) simultaneously for all audible appliances. This ensures a distinct temporal (code 3) pattern when 2 or more audibles are within hearing distance. If not synchronized the temporal sound could overlap and not be distinctive, At the same time the strobes will be synchronized. This provides the ability to comply with ADA guidelines concerning photosensitive epilepsy and the NFPA standards when installing 2 or more visual appliances within the field of view all of this plus the ability to silence the audible is achieved by using only 2 wire. Features Approvals include: UL Standard 1971 UL Standard 464 New York City (MEA), California State Fire Marshal (CSFM) Factory Mutual (FM), and Chicago (BFP). See app rQvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI Compliant Wall mount models are available with Field Selectable Candela Settings of 15/30/75/110cd or 135/185cd (IVlulti Candela models) or 1575cd (single candela model) Ceiling mount models are available with field Selectable candela settings of 15/30/75195cd or 115/177cd (multi-candela ceiling models) Selectable Continuous Horn or Temporal (Code 3). 3 Selectable dBA settings (99, 95 and 90 dBA) in both tones Patented 2-01ire Audible Strobe Appliance. Patented Universal Mounting Plate Weatherproof models are available for outdoor use Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL Regulated Voltage Range using filtered DC or unfiltered FWR input voltage The strobes can be synchronized using Wheelock's sync modules or power supplies with built in sync proto00 Fast installation with IN/OUT screw terminals using 912 to #18 AWG wires For Wea1hiproof Series A. SCnj Dv.sheet SfiOO4 MEA iiii APPROVED E5946 151-v2.E -1 125-0781 NOTE: All CAUTIONS and WARNINGS are identified by the symbol Al. All warnings are printed in bold capital letters. Al WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT, VISIT WWV.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO Y u AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of i to 2 flashes per second and ADA Guidelines specify a flash rate of 110 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe Products are listed under UL Standard 1971 for indoor use with a temperature range at 32F to 120F CC to 49'C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use Only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Ratings Per UL 1971 Model Number - Input Voltage VDC Regulated Voltage Range L VDC/FWR Strobe Candela (Cd) AS-24MCW 24 16.0-33.0 15/30/75/110 AS-24MCCH 24 16.0-33.0 115/177 AS-241575W 24 16.0-33.0 15 (75 on Axis) AS-121575W 12 8.0-17.5 15 (75 on Axis) AS-24MCC 24 16.0-33.0 15/30/75/95 AS-24MCWH 24 16.0-33.0 135/185 ASWP-2475W 24 16.0-33.0 75 @ -31F Table 2: dBA Ratings for 12 VDC and 24 VDC Series ASIAH 12 and 24 VDC Audible Reverberant I Anechoic Description Volume dBA Per UL 464 dBA @10 ft. @10 ft. High 91 99 Continuous Medium 88 95 Horn Low 83 90 High 87 99 Medium 84 95 Code 3 Horn Low 79 90 Table 3: Average RMS Current Audible Wall Mount Audible Strobe Models Ceiling Mount Audible Strobe Models AH-24 AS-241575W AS-24MCW AS-24MCWH 24 VDC Models AS-24MCC AS-24MCCH 1 575c l5cd 30cd 75cd llOcd 135cd 185cd 15cd 30cd 75cd 95cd ll5cd 177cd High (99) 24 vdc 0.062 0.100 0.080 0.102 0.150 0.194 0.250 0.320 0.088 0.114 0.165 0.205 0.250 0.320 dBA UL max* 0.080 0.121 0.088 0.125 0.200 0.267 0.355 0.480 0.095 0.138 0.221 0.285 0.355 0.480 24 vdc 0.033 0.080 0.060 0.084 0.132 0.173 0.230 0.305 0.066 0.092 0.145 0.186 0.230 0.205 Med (95) dBA UL max 0.043 0.107 0.074 0.110 0.190 0.253 0.340 0.465 0.080 0.122 0.201 0.269 0.340 0465 24 vdc 0.017 0.072 0.052 0.076 0.121 0.158 0.220 0.295 0.056 0.082 0.132 0.173 0.220 0.295 Low (90) d8A UL max* 0021 0.100 0.068 0105 0.182 0.245 0.335 0.4600.074 0.113 0198 0.263 0.335 0.480 Wall Mount Audible Audible 12 VDC Models Strobe Table 4: Average Current* (AMPS) For SeriesSVP A High dBA Medium dB' Low dBA A. H-12AS-121575W Voltage Setting Setting Setting ........ (99) dBA (95) dBA (90) dBA I-tgh i9 12 dc 0.183 0250 4 0 IDC 0128 0051 0.088 d131- ULna,010 0 jj 01O Med (82) 12idc 0.070 0 1195 'JEA ma,' 0 102 0 275 i 'RiAS current ratings are per UL aierage PiAS method UL max ourrent rating is the rna/irnurh RMS currer,iw:th:n the listed 'oltage range 116-33i Lou o 12 edo 8.028r,, 17 (or 24i units i For strobes the UL rna/ current is usually at the m!nimurn E li'd 'jttO (101 / 24 urik Frru oicle then a' r er lsusJdllJ .JL mu, . o U m.imi j licth en:ttnp (33,j Mr 24, Hnik Pr,c ,,nfiItr P///P ratings. see installation instructions. (Approvals CSFMTFMTBFP Wiring Diagrams SERIES AS AP PLIANC ES NON SYNCH RON IZED FROM TO NEXT PRECEDING ____ I APPLIANCE APPLIANCE OR EOLR OR FACP SERIES AS APPLIANCES SYNCHRONIZED WITH SM MODUL OLE CLASS "B" NAC CIRCUIT WITH AUDIBLESILENCE FEAT FRE SM AØ SAC Clrcelt I SERIES AS APPLIANCES SYNCHRONIZED WITH MULTIPLE SM MODULES Audible NAC Cu DSM Ill Strcbe NAC Cir Sync HF I I A S AS Audible NAC Cr DSM #2 Strobe NAC cYflCT 0+ Audible NAC dir' P [robe NAC i Sync 0+ SERIES AS & RSS APPLIANCES SYNCHRONIZED WITH PS-12/24-8Cp and PS-12/24-8Mp OUTPUTS EOLR 'CLASS A. OR AS C S-CASS P AS RR S,is PS-12/24-BCP o PS-)2/2,1 8KIP SERIES AS APPLIANCES SYNCHRONIZED WITH DSM MODULE CLASS"A" NAG CIRCUIT WITH NO AUDIBLE SILENCE FEATURE DSM Interconnecting wiring shown. Maximum of twenty (20) For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring informationon the power supplies refer to Installation Instructions P84662 for PS-24-8MC. Specifications and Ordering Information Model Number Order Code Strobe Candela Non- Sync wISM, DSM or 24 vc 12 vb c Wall Mount Ceiling Mounting Options *** Agen AS-24MCW-FR 9024 15/30/75/110 X X X - X - A,BDEFOHJ,N,O,RX X X AS-24MCW-FVV 9025 15/30/75/110 X X X - X - A,BDE,FGHJNOR,X X X AS-24MCWH-FR 3468 135/185 X X X - X - ABD,E,FGHJ,NOR,X x x AS-24MCWH-FW 3469 135/185 X X 7 - X - ABDEFGH,JNOR,X x x AS-241575W--FR 7405 15 (75 on Axis) X X X - X - ABDEF,GHJNOR,X X X AS-121575W-FR 7410 15 (75 on Axis) X X - X 7 - ABD,FGHJNORX X X AS-24MCC-FR 3161 15/30/75/95 X 7 7 - - 7 ABD,EF,GHJNOR,X X X AS-24MCC-FW AS 24MCCH FW 3162 3467 15/30/75/95 X 7 7 115/177 - / / / 75 -31°F X / - X /- - / - / / - 7 - - - X 7 / ABD,EFG,HJN.OR,X ABDEFGHJNOPX (see Data Sheet S9004) AD, E. F.Hi'JOR,X 7 / 7 / X 1 X ASV/JP2475Ai-FR" AHR AH-24-'1'J 9012 7892 7893 / / ABDEFGHJ,N O,R.X 7 7 AH-12-R 7891 AH-12-VJ i789 - X 7 7 X / 7 7 XjB.D.EFGH.JNOx ABD.E,F,G,H J.N.O,R.X K 7 7 - / 7 -7.7 AH-24V\JPP" 7416 7415 X. X I X X I / I / "For Viealherproof Series AS/AH specifications see data sheet 69054. PENDING '"Refer to Data Sheet S7000 for Mounting OptionS, Note: Models are availsole in either Red or White. Contact C'JSlorner Service for Order Code and Delivery, NOTE: Due to continuous development of our products, specifications and offerings are subject to change withsut notice in Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS Audible Strobe appliances and Series AH Audible appliances or approved equals. The SeriesAS Audible be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 454 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarni Control Panel (FACP). The audible Portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. The Series AS shall be of low current design. Where Multi— Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110 or 135/185 candela for wall mount and 15/30/75/95 or 115/177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant, The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). When synchronization is required the appliance shall be compatible with Wheelocks SM. DSM Sync Modules orWheelock PS-24-8M0 Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash— rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock synchronization. The Series AS Audible Strobe and Series AH Audible shall incorporate a Patented Universal Mounting Plate that shall allow mounting to a single-gang, double-gang 4-inch square, 100mm European type backboxes or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. 273 Branchporf Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 Fax' (732) 222-2588 wwv. coo perwheelock .com WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRA1p' Made RIJSA CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -24300, -24750 and -241000 audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model AS-24M0W and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP-2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations RATING: Electrical: 8-17.5/16-33 VDC/VFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:110cd MOW: Selectable 15cd, 30cd, 75cd, 110cd MOO: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable 115cd. 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS. 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. *Rev. 06-13-06 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. 'Rev. 06-13-06 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the lest results and/or other data but does not make an independent verification of any Claims. This listing is not an endorsement or recommendation of the item listed This listing should not be used to verify correct operational requirements or installation criteria. Refer to istee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager 00 COOPER Wheelock Series RSS and RSSP Strobes and Strobe Plates AZZ IRE : 677 ji Series RSS Series RSS Series RSSWP RSS Round Description The Wheelock patented Series RSS Strobe Appliances and Series RSSP Strobe Plates have lower current draw while maintaining outstanding performance, reliability and cost effectiveness. These versatile appliances will satisfy virtually all requirements for indoor, wall or ceiling mount applications. Strobe options for wall mount models include 1575 or the Wheelock Patented MCW multi-candela strobe with field selectable candela settings of 15/30/75/10ed or the high intensity MCWH strobe with field selectable 135/185cd. Ceiling mount models include the patented MCC multi-candela ceiling strobe with field selectable intensities of 1 5/30/75/95cd or the high intensity MCCH strobe with field selectable 115/177cd. All models may be synchronized using the Wheelock SM, DSM Sync Modules or the PS-24-8MC Power Supplies with the Wheelock Patented Sync Protocol. Synchronized strobes can eliminate possible restrictions on the number of strobes in the field of view. Wheelock's synchronized strobes offer an easy way to comply with ADA recommendations concerning photosensitive epilepsy as well as meeting the requirements of NFPA 72. The Wheelock Series RSS Strobes employ a Patented Integral Strobe Mounting Plate that can be mounted to a single gang, double gang, 4" square, 100mm European backboxes or the SHBB surface backbox. If the flush backbox has side or top space between it and the finished wall, the NATP (Notification Appliance Trimplate) may be used. It provides an additional .65" of trim for the Appliance. An attractive cover plate is provided for a clean, finished appearance on all models. The Series RSSP Multi-Candela Strobe Plates are a cost effective way to retrofit required wall strobe appliances to bells, horns, chimes, multitones or speakers and easily mounts to standard 4" backboxes or for surface mount use with the Wheelock SBL2 surface backbox. MEA APPROVED S5391 151-92-E 7125-0785:141 Features Approvals include: UL Standard 1971, New York City (MEA), California State Fire Marshal (CSFM), Factory Mutual (FM), and Chicago (BFP) See approvals by model in Specifications and Ordering Information ADA/NFPA/UFC/ANSI compliant. Meets OSHA 29 Part 1910.165 Wall mount Multi-Candela models are available with Field Selectable Candela Settings of 15/30/ 75/1Oed or 135/185cd. Single Candela models are available in 1575cd Ceiling mount Multi-Candela models are available with field selectable candela settings of 15/30/75/95cd or 115/177cd. (Round or Square) Strobes produce 1 flash per second over the regulated voltage range 12 and 24 VDC models with wide UL "Regulated Voltage" us- ing filtered (DC) or unfiltered VRMS input voltage Synchronize using the Wheelock sync modules or power sup- plies with built-in sync protocol Fast installation with IN/OUT screw terminals using #12 to #18 AWG wire For Weatherproof Series RSS See Datats/ieet S9004 NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERWHEELOCK.COM OR CONTACT COOPER WHEELOCK FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: Strobes are designed to flash at 1 flash per second minimum over their Regulated Voltage Range. Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 t 3 flashes per second. All candela ratings represent minimum effective Strobe intensity based on UL Standard 1971. Series NS Strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series NH horns are listed under UL Standard 464 for audible signal appliances (Indoor use only). "Regulated Voltage Range" is the newest terminology used by UL to identify the voltage range. Prior to this change UL used the terminology "Listed Voltage Range". Table 1: Average RMS Current* RSS/RSSP -Wall Mount I Ceiling Mount RSS/RSSP 241575W 24MCW 24MCWH 24MCC 24MCCH 24VDC I I I Models I I I I I I I 1575cd l5cd I 30cd 75cd ilOcd I 135cd 185cd 15cd 30cd I 75cd I 95cc1 I 115cd J 177cd UL max* 0.090 0.060 0.092 1 0.165 0,220 0.300 1 0.420 1 0.065 0,105 0.189 0.249 1 0.300 1 0.420 RSS/RSSP RSS/RSSP Wall Mount 24VDC _____________ * RMS current ratings are per UL average RMS method. UL max current Models 121575W rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum 12 vdc 0.152 listed voltage (16v for 24v units). For audibles the max current is usually at UL max* 0.255 the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. Table 2: Audibles/Speakers for RSSP Strobe Plate Product Series Multitone Appliances AMT, MT Horns AH, NH, HS Motor Bells MB-G6IG10 Speakers ET-1010/1080, E70, ET70 Chimes CH70 Wiring Diagrams SERIES RSS/RSSP APPLIANCE FROMTi TO NEXT +— r +. PRECEDING _APPLIANCEI I APPLIANCE, SYNC:., OR EOLRL1 NODULE, POWERL SUPPLY OR FACP —L SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH DSM MODULE SINGLE CLASS "A" NAC CIRCUIT DSM[J ACP SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH MULTIPLE DSM MODULES OEM #1 DSM Interconnecting wiring shown. Maximum ofL twenty (20)1 STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE IN UNISON TO NEXT FROMi + APPLIANCE- ,' PRECEDINGO _ I i —0R ECLE APPLIANCE, SYNC '1ODULE, PONERC SUPPLY OR FACP_ ± :rr,oss: AUL1EWE STROBE/PLATE ASSEMBLY AUDIBLE & VISIBLE APPLIANCE OPERATE INDEPENDENTLY LL r- +-1r --- +L - STROBEI. APE LIANCE # For detail using SM or DSM Sync Module refer to Data Sheet S3000 or Installation Instructions P83123 for SM and P83177 for DSM. For wiring information on the power supplies refer to Installation Instructions P84515 for PS- 12/24-8CP and P84333 for PS-1 2/24-8M P. Specifications and Ordering Information SERIES RSS/RSSP APPLIANCE SYNCHRONIZED WITH SM MODULE SINGLE CLASS "B" NAC CIRCUIT S M[i FE 0 :sosc.. 0 ALl L CE 0 Audi±Te SERIES RSS/RSSP APPLIANCES SYNCHRONIZED WITH PS-12124-8CP or PS-12124-8MP Fl OUT 1-47 PUTS II11EiIIIi - CLASS AS C 3-i~~ FS-1 2/24-etlz Model Order Code Wail Mount Ceiling Mount Non- Sync Strobe Candela 24 VDC 12 VDC Color RED Color WHITE Mounting Square or Round Agency Approvals - UL MEA CSFM FM BFP RSS-24MCW-FR 940 X - X 15/30/75/110 X - X - B,DE,F,G,H,J,N,O,R,X Square X X X x x RSS-24MCW-FW 9401 X - X 15/30/75/110 X - - X B,D,E,F,G,HJN,OR.X Square X X X X X RSS-241575W-FR 7471 X - X 15(75onAxis) X - X - B,DE,F,GH,J,NO,R,X Square X X X x x RSS-241575W-FW 7788 X - X 15(75onAxis) X - - X BDE,FG.H.J,N,O,R,X Square X X X x x RSS-121575W-FR 7476 X - X 15(75onAxis) - X X - BD,EF,G,I-IJN,O,R,X Square X X X x x RSS-121575W-FW 7468 X - X 15 (75 on Axis) - X - X BD,E,FG,H,J,N,O,R,X Square X X X x x RSS-24MCC-FW 3158 - X X 15/30/75/95 X - - X B,D,EF,G,H,J,NO,R.X Square X X X X * RSS-24MCC-FR 3157 - X X 15/30/75/95 X - X - BDEFGH,J,NO,R,X Square X X X x * RSS-24MCCR-FW 3160 - X X 15/30/75/95 X - - X BDEFG,H,J,N,OR,X Round X X X x * RSS-24MCCH-FW 3461 - X X 115/177 X - - X B,DEF.G,HJNO,R,X Square X X X x * RSS-24MCCHR-FW 3463 - X X 115/177 X X BDE,F,GH,JNO,R,X Round X X )( 3465 X X 135/185 x RSS-24MCWH-FR X BDEF.G,H,JNOR,X Square X X X x RSS-24MCWH-FW 3464 X X 135/185 XX Ix BDEF,GHJ,NOR,X Square X X X x RSSWP2475WFR** 9013 X - X 180@ 77-F X - B,D,EF,G,H,JNO,R,X Square X X X X * RSSWP2475WFW** 3034 X - X $537 X X - X BDEF,GH,JNOR,X Square x x x x RSSP-121575W-FR 7798 X - X =(75on - X X - DE,Z Square X X X x x RSSP-24MCW-FR 9402 X - X 15/30/75/110 X - X - DE,Z Square X X X x x RSSP-241575W-FR 7793 X X 1 15 (75 on Axis) - - X - DE,Z Square X X X x x *PENDING All models sync with Wheelock SM, DSM or PS-12/24-8CP or PS-12/24-8MP. # Models are available in either Red or White. Call Customer Service for Order Code & Delivery. **For Weatherproof Series RSS Strobe specifications see data sheet S9004. ***Refer to data sheet S7000 for mounting options. Architects and Engineers Specifications The visual notification appliances shall be Wheelock Series RSS Strobe Appliances or approved equals. The Series RSS shall meet and be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The strobe shall be listed for indoor use and shall meet the requirements of FCC Part 15 Class B. The strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan® lens. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). When Strobe Plates are to be installed, they shall be the Wheelock Series RSSP Strobe Plate and shall have the same electronic circuitry as the Wheelock Series RSS. The Series RSS Strobe shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have field selectable settings and shall be rated per UL Standard 1971 at 15/30/75/110cd or 1351185cd for wall mount and 15130/75/95cd or 115/177cd for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 1575 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM, DSM Sync Modules or the Wheelock PS-24- 8MC Power Supplies with built-in Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync module or Power Supply fails to operate, (i.e., contacts remain closed), the strobe shall revert to a non-synchronized flash rate. The strobes shall be designed for indoor surface of flush mounting. The Series RSS Strobe Appliances shall incorporate a Patented, Integral Strobe Mounting Plate that shall allow mounting to single- gang, double-gang, 4-inch square, 1 00m European type backboxes, or the SHBB Surface Backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. An attaching cover plate shall be provided to give the Appliance and attractive appearance. The Appliance shall not have any mounting holes or screw heads visible when the installation is completed. The Series RSSP Multi-Candela or single candela Strobe Plate shall mount to either a standard 4 inch square backbox for flush mounting, or the Wheelock 56L2 backbox for surface mounting. All notification appliances shall be backward compatible. NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Wheelock, Inc. standard terns and conditions. 00 COOPER Wheelock 273 Branchport Avenue Long Branch, NJ 07740 Phone: (800) 631-2148 WE ENCOURAGE AND SUPPORT NICET CERTIFICATION Fax: (732) 222-2588 3 YEAR WARRANTY www.cooperwheelock.com Made in USA 50410 RSS/RSSP 07107 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:141 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Wheelock Inc., 273 Branchport Ave., Long Branch NJ 07740 Contact: Luy Nguyen (732) 433-6005 Fax (732) 222-5607 DESIGN: Synchronized or non-synchronized Strobe Lights. Models are as follows: RSS-##W RSSP-##W RSS-##C RSSP-##C RSS-##CR RSSP-##CR 2415 2415 2415 2415 2415 2415 2475 2475 2430 2430 2430 2430 241575 241575 2475 2475 2475 2475 2430 2430 *2495 *2495 *2495 *2495 24110 24110 1215 1215 121575 121575 Also, Models RSS-24MCW and RSSP-24MCW, RSS-24MCC, RSS-24MCCR, RSSP- 24MCC, RSS-24MCWH, RSS-24MCWHR RSSP-24MCWH, RSS-24MCCH, RSS- 24MCCHR, RSSP-24MCCH, *ZRSMCC *ZRSMCW *ZRSMCCH and *ZRSMCWH Model numbers may be followed by any two alpha/numeric character indicating lens orientation, lettering and color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical 12 = 8-17.5VDC/FWR OR 24 = 1 6-33VDC/FWR Candela 15=5cd, 1575=15/75cd on axis, 3030cd, 7575cd, 110110cd (Wall) RSS-24MCW, RSSP-24MCW, *ZRSMCW: Selectable 15cd, 30cd, 75cd or 1 10c RSS-24MCC, RSS-24MCCR, RSSP-24MCC, *ZRSMCC: Selectable 15cd, 30cd, 75cd and 95cd RSS-24MCWH, RSS-24MCWHR, RSSP-24MCWH, *ZRSMCWH: Selectable 135cd, 185cd RSS-24MCCH, RSS-24MCCHR, RSSP-24MCCH, *ZRSMCCH: Selectable 115cd, 177cd Flash rate 60 flashes/minute INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models with suffix -W, wall mount only. Models with suffix -C, ceiling mount only. All models are for indoor use only. MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as strobe light suitable for the hearing impaired when used with separately listed electrically compatible fire alarm control units. For synchronization strobes, Models SM- 12/24, SMX-12124, DSM-12/24 or DSMX-12/24 Sync Control Module (CSFM Listing No. 7300-0785:132) must be used. Refer to listee's Installation Instruction Manual for details. *Rev. 12-13-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 4, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager