Loading...
HomeMy WebLinkAbout6797 EMBARCADERO LN; ; FA150053; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA150053 6797 Job Address: EMBARCADERO LN Permit Type: FALARM Parcel No: 2146500101 Lot #: 0 Reference No.: PC #: Status: PENDING Applied 8/21/2015 Approved: Issued: Inspector: Project Title: DEHESA CHARTER SCHOOL INSTALL ADDRESSABLE FIRE ALARM SYSTEM FOR FIRST FLOOR OCCUPANT. INCORPORATE EXISTING ELEVEATOR CONTROL SYSTEM INTO THIS NEW FIRE ALARM SYSTEM. NOTE: THERE ARE NO AIR HANDLERS ABOV 2000CFM Applicant: SENTINEL SECURITY SYSTEMS 1859 S. ESCONDIDO BL ESCONDIDO, CA 760-741-0890 Owner: MACQUARIE POINSETTIA INC 1420 5TH AVE #2220 SEATTLE WA Fees ($) Add'I Fees ($) Total ($) Balance ($) 289 0 289 0 DEH,ES,A CHARTER SiCROOL, 6797 Embarcadero. Lane Carlsbad, CA 92011 Specification Documentation. for: Fi zi - re Alarm. System raw* a 0- SENTINEL SECURITY SYSTEMgi m ALARM COMPANY OPERATORS LICENSE ACO 140 STATE CONTRACTORS LICENSE C40 4541177 40< 1859 S. Escondido Boulevard Escondido, CA 92025 Submitted By: Zak Pescar Phone No.: (760) 741-0890 08/19/15 0- U3ilIV8flS OJd&1 FA150053 DEHESA CHARTER SCHOOL TABLE OF CONTENTS FACP (POTTER P400 & D ANNUNCIATOR) DATA SHEET PG. 1-5 LISTING SHEET PG. 6 VOICE EVACUATION SYSTEM DATA SHEET PG. 7-8 LISTING SHEET PG. 9 ALARM BOX (PULL)- ADDRESSABLE DATA SHEET PG. 10-11 LISTING SHEET PG. 12 SMOKE DETECTOR- ADDRESSABLE DATA SHEET PG. 13-14 LISTING SHEET PG. 15 HEAT DETECTOR- ADDRESSABLE DATA SHEET PG. 16-17 LISTING SHEET PG. 18 SPEAKER/STROBE (WALL & CEILING) DATA SHEET PG. 19-21 LISTING SHEET PG. 22 RELAY OUTPUT MODULE DATA SHEET PG. 23-24 LISTING SHEET PG. 25 RELAY (120 VAC) DATA SHEET PG. 26-27 LISTING SHEET PG. 28 INPUT MODULE- ADDRESSABLE DATA SHEET PG. 29-30 LISTING SHEET PG.31 WIRE-FIRE DATA SHEET PG. 32-35 0 LISTING SHEET PG.36 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0198 Page 1 of 1 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN: Models *pFc..6500 fire alarm control panels Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: CA-6500: Class A Expander UD-1000:DACT *3006607*3006610*3006623*3006623*3006618: Main Boards RA-6075, RA-6075}6500: Rmote Annuciators 3005013, 3005012: EOL Resistors PSN-1000, PSN-1000(E): Fire Power Expander Models AE-8, AE-14; Power expander enclosures SLCE-127: Loop Expander RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. NOTE: *For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev 03-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTIO N OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 6911-0328:0219 Page 1 of 1 CATEGORY: 6911 -- VOICE COMMUNICATION SYSTEMS CONTROL UNITS LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63 0 4 2 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Modejr25E, -50,-50E, -100, -100E, -150,-150E, -200,-200 E a u d i o a d j u n c t system4heseunits are intended to be used in conjunction with a l i s t e d e l e c t r i c a l l y - . compatible fire alarm control unit to provide voice communication, pa g i n g , e v a c u a t i o n t o n e signals, and voice alarm signals with voice override. Refer to listee ' s d a t a s h e e t f o r d e t a i l e d product description and operational considerations. RATING: Input: 24-32 VAC/DC, Standby: 24 VOC, PVX 25/ 25E / 50/ 50E 7-18 Ah Battery PVX 100 / 100E 7-24 Ah Battery INSTALLATION: In accordance with listee's printed installation instructions, wi r i n g d i a g r a m , a p p l i c a b l e c o d e s and ordinances and in a manner which is acceptable to the authority h a v i n g j u r i s d i c t i o n . MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a voice/tone communication/evacuation/relocation/audio a d j u n c t s y s t e m f o r u s e with separately listed electrically compatible fire alarm speakers a n d c o n t r o l u n i t s . Supervision is dependent upon the fire alarm control panel. Refer t o t h e c o n t r o l p a n e l ' s l i s t i n g . and installation instructions for proper configurations. Suitable for hi g h r i s e a p p l i c a t i o n s w h e n used in conjunction with separately listed fire alarm control units. R e f e r t o l i s t e e ' s I n s t a l l a t i o n Instruction Manual for details. XLF: 6911-1446:0100 08-06-13 gt This listing is based upon technical data submitted by the a p p l i c a n t . CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an i n d e p e n d e n t v e r i f i c a t i o n o f a n y c l a i m s . T h i s l i s t i n g i s n o t '- an endorsement or recommendation of the item listed. T h i s l i s t i n g s h o u l d n o t b e u s e d t o v e r i f y c o r r e c t operational requirements or installation criteria. Refer to listee ' s d a t a s h e e t , i n s t a l l a t i o n i n s t r u c t i o n s a n d / o r o t h e r Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0328:0201 Page 1 of I - CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN: Models APS-SA single action adAPSDA'd9at action addressable pull boxes. Refer to listee's data sheet for additional description and operational considerations. - . RATING: 22-24VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, .rating and UL label. APPROVAL: Listed addressable pull boxes for use with separately listed and compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. S 02-06-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division /- CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE —0 0 LISTING No. 7272-0328:0194 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co 1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: ModeAjd PSHA photoelectric type smoke detectors. Model PSHA employs a supplemental heat sensor. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 22-24 VDC * INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units when used in conjunction with listee's Models AB-4, AB-6, ASB, AIB and ARB bases.Models with supplemental heat sensor are not approved for use in lieu of the required heat detectors. C 12-23-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not . an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING- BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0328:0193 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billwpottersignal.com DESIGN: Model HIand RHA heat detectors. Model FHA is a 135-185 OF fixed temperature heat detector and Model RHA is combination 15 OF rate-of-rise and 135-174 OF fixed temperature heat detector. Unit consists of resistors, capacitors, diodes, transistors, LED, thermistors, mounted on a printed wiring board inside an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: FHA: 135-185 OF fixed temperature RHA is combination 15 OF rate-of-rise and 135-174 OF fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as heat detector for use with model AB-4, AB-6, AIB, ASB or ARB bases and separately listed compatible fire alarm control units. 12-23-10 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7320-0328:0208 Page 1 of I CATEGORY: 7320 - SPEAKERS LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN: Model FASPKRing and wall mounted speaker. lSPKST24CLP1 mounted speaker strobe. Models FASPKR and SPKSTR-24CLP are availaliirfred or white. Models are to be mounted in standard 4" X 2 1/8" back boxes. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Speaker 25 Vrms and 70.7 Vrms Strobe 21-30 VDC Flash Rate 60 flashes per minute Candela 15, 30, 75, 95 and 115 cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/candela ratings and UL label. APPROVAL: Listed as speakers and speaker strobes for use with separately listed compatible fire alarm control units. Units with strobe lights are suitable for the hearing impaired applications. For indoor use only. XLF: 7320-0569:0137 07-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM - LISTING SERVICE LISTING No. 7165-0328:0196 Page 1 of 1 CATEGORY: 7165 - FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw©pottersignal.com DESIGN: Models PFC- 8060, PFC-8060/230, PFC-8500 and PFC-85001230 fire alarm control units. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, • releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PFC-8000: Power Supply ALE-127: Loop Expander Board 3005013, 3005012: EOL Resistors LCD-AN, LED-AN: Remote Annunciators CIZM-4: Smoke Detector Module SCI: Loop Powered Short Circuit Isolator MCM:Miniature Contact Module SCM-41DC M-4: Loop Powered Contact Modules C-1—R—M-4: Twin Relay Module MOM-4: Monitor Output Module 24VDC RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Units meet the requirements of UL Standard 864, 9th edition. 04-11-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct v% operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:0101 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Apollo America lnc.25 Corporate Dr., Auburn Hills, Ml 48326 Contact: John Schertel (248) 332-3900 Fax (248) 332-8807 Email: John.Schertel©apollo-fire.com DESIGN: Models MR-101/C, *MR..lollc/R *MR..101..sSEIc *MRI01..SSEJC/R MR-104/C, *MR104/C/R, *MR104..sSE/C *MR..104.SSE/c/R MR-201/C, MR201/C/*R, *MR20 1-SSE/C, *MR..2SsE/C/R MR-204/C, MR204/CI*R, *MR204..ssE/C *MR2o4ssE/c/RtAM18pA2 PAM-3, PAM-4, PAM-SD, RlC-1, RIC-2, RIC- 3 , R l C - 4 , MRRIC301/*C,(MRRtCa0tC/R, MRRIC305*/C, * MR-RIC-305/C/R, MRRlC401*/C, *MR..RlC401IC/R MRRIC405*/C and *MR..Rlc..405/CIR relay modules. *Models MR-ITM/C and MR-ITM/C/R relay modules (with test mode). Refer to listee's data sheet fo r d e t a i l e d product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & o r d i n a n c e s a n d in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible fire alarm co n t r o l u n i t s . 4V NOTE: Refer to manufacturer's Installation Manual for details. 1. Formerly Air Products and Controls, Inc. Rev. 04-03-14 gt This listing is based upon technical data submitted by the applicant CSFM F i r e E n g i n e e r i n g s t a f f h a s r e v i e w e d the test results and/or other data but does not make an independent verificati o n o f a n y c l a i m s . T h i s l i s t i n g i s n o t . an endorsement or recommendation of the item listed. This listing sh o u l d n o t b e u s e d t o v e r i f y c o r r e c t Iry operational requirements or installation criteria. Refer to listee's data sheet, installation instruc t i o n s a n d / o r o t h e r 1' Date issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Enaineerina Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0196 Page I of 1 CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, MO 63042 Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: biIIwpottersignal.com DESIGN: Models PFC- 8060, PFC-80601230, PFC-8500 and PFC-8500/230 fire alarm control units. Automatic, Manual, waterfiow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components: PFC-8000: Power Supply ALE-127: Loop Expander Board 3005013, 3005012: EOL Resistors LCD-AN, LED-AN: Remote Annunciators ClZM-4: Smoke Detector Module SCI: Loop Powered Short Circuit Isolator Contact 'di SCM-4, DCM-4: Loop Powered Contact Modules TRM-4: Twin Relay Module MOM-4: Monitor Output Module RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. Units meet the requirements of UL Standard 864, 9th edition. 04-11-11 bh Tt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct 'v operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2015 Listing Expires June 30, 2016 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM S LISTING SERVICE LISTING No. 7161-1487:0100 Page 1 of I CATEGORY: 7161 -- CABLES-FIRE PROTECTIVE SIGNALING LISTEE: Contact Orville Allen (262) 947-0720 Fax (262)9470724 Email: orville@genesiscable.com DESIGN: Model FPL, FPLP and FPLR power limited fire protective signaling cable. Conductors: In accordance with the standard Insulation: GPT-150, Foam PP, HDPE or LOPE Assembly: 2 to 12 insulated conductors Shield (Optional): Aluminum polyester tape shield Braid (Optional): Metal braid over cable core Jacket: PVC compound Gitto/Global Corp., Grade GA-91-84, GPT-45, G A 5 0 3 3 , G A 9 3 0 1 6 Refer to listees data sheet for detailed product description and operatio n a l c o n s i d e r a t i o n s . INSTALLATION: In accordance with listees printed installation instructions, applicable c o d e s & o r d i n a n c e s , NEC Article 760, and in a manner acceptable to the authority having jurisd i c t i o n . MARKING: Listees name, Type 'FPL" and UL label. APPROVAL: Listed as power-limited fire protective signaling cables. ... Rev. 06-18-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent ver i f i c a t i o n o f a n y c l a i m s . T h i s l i s t i n g i s n o t an endorsement or recommendation of the item listed. This listing sh o u l d n o t b e u s e d t o v e r i f y c o r r e c t S operational requirements or installation criteria. Refer to listee's data sheet, ins t a l l a t i o n i n s t r u c t i o n s a n d / o r o t h e r Date Issued: July 01, 2014 Listing Expires June 30, 2015 Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division