Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 132; FPC2017-0155; PermitCARLSBAD, CA 92008-1207 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Print Date: 02/03/2022 Job Address: 2525 EL CAMINO REAL, # 132, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $66,974.40 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Permit No: FPC2017-0155 Status: Closed - Finaled Applied: 06/05/2017 Issued: 06/14/2017 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: PERMIT REPORT Lcity of Carlsbad Project Title: Description: WATCH EDGE -SPRINKLER TI 7-100 HEADS (19) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ALEXIS CASSIDY 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov 01TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 17502 WATCH EDGE The Shoppes at Carlsbad 2525 El Camino Real #132 Carlsbad, CA 92008 FPC20I 7-0155 2525 EL CAMINO REAL UNITI32 FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response 1 V2703/V2 704 V2707/V2 708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to /4719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. \4taU11cr 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.' Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 40.10 2544 Rev. j updated 07/2014 © 2014 victaulic company. All rights reserved. 1 JtauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS 011000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: El Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS 065100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: Eli Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated El White painted3 El Black painted3 El Custom painted3 El Proprietary Nickel Teflon2 coating3 El VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 \,JtauIiC victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" 1/2" 1/2" /2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/19°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 200°F/93°C 200°F/93°C 175 °F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C FM 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141 °C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C NYC/MEA 62-99-E 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/1 41 °C 286°F/141°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286° F/i 41 °C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C CSFM 7690-0531:112 200°F/93°C 200°F/93°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 200°F193°C 200°F/93°C 200°F/93°C 360°F/182°C 360°F/182°C 286°F/141°C 286°F/141°C 286°F/141°C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 155°F/68°C None None 200°F/93°C 175°F/79°C 286°F/141°C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286°F/141°C 200°F/93°C 286°F/1 41°C 286°F/1 41°C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68°C 155°F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 2007/93°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360'F/1 82'C 135°F/57°C 135°F/57°C 155°F/68°C 55°F/68°C 1 CE 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 86°F/141 °C 2 360'F/1 82'C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. j updated 07/2014 0 2014 Victaulic Company. All rights reserved. victauliccom 3 'u4tauiic victaulic.com I Sprinklers I FireLock® I k5.6, V27 I Publication 40.10 Dimensions: 1?A6'/ 37 mm 2Ia'I 60 mm 1W! I 41 mm 1W! 2W! 41 mm 60 mm Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Mir, m Hole I 1 3As7 mx! 17 mm Typical Ceiling Tile ,30m _ 1 _ 1W! Finished Surface 30 r 43 mm MAXIMUM RECESS 211A6"/ 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/60 mm Max. Hole 2"/51 mm Min. Hole Typical Ceiling Tile 1W! Typ g 18mm 1W! 24 mm 37 mm MAXIMUM RECESS 24' mm Finished Surface 75 mm MAXIMUM EXTENSION 3/4"Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 4 ACtauIic 4' Un, 2' 0.6m a victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent 2' 4' 6' 8' 10' 12' 14' 0.6n, U. 1.8,,, 2.4,,, 3.0n, 3.7,,, 4.3n, Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory 2' 4' 6' 8' 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4,,, 3am 3.7,,, 4.3,1, 49m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 5 iict:aullil 10, 8' 2.4,,, 6 1.8n, 4, 1.2,,, 2' 0.6m 0 7psi 48 kPa 15 psi 103 kPa 30p51 207 kPa 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F157 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8/107 C Blue Extra High 1< 360 F/182 C 300 F/149 C Purple - M Open - No Bulb Standard response only. 8150/65 if was coated. Available Wrenches: V27-2 Recessed V27 Open End V2707V2708Pendent / / V2707,V2708 Recessed Pendent / - V2703, V2704 upright I A WARNING ... Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. Installation Note Reference should always be made to the -40 Victaulic FireLock Automatic Sprinklers This product shall be manufactured by Victaulic or to Victaulic specifications. All products Installation and Maintenance Sheet for the product you are installing. This installation sheet to be installed in accordance with current Victaulic installation/assembly instructions. is included with each shipment of Victaulic products for complete installation and assembly Victaulic reserves the right to charge product specifications, designs and standard data, and is available in POE format on our website at victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic is registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 6 Jl'ctauIills Bull Moose Tube'sO Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's® Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM A123 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED H1PRM NFPA El SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 1527 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1/2 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 6.27 2.64 lbs/ft 4.223 37 2-1/2 2.875 2.635 4.92 3.53 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WATER FILLED BUNDLE WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 2.27 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 2.72 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10.80 lbs/ft 16.316 19 Only available in Casa Grande, AZ "corrosion Resistance Ratio per latest lii Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road U Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas, X Masury, OH 63017 Dull Moose Tube's® Eddythread 40 ADVANTAGES OF BULL MOOSE TUBE® EDDVTHREAD 40® I) isa lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD Il® MIC preventative coating. EDDVTHREAD 40® SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LB.!FT WEIGHT SIZE 1 1.295 1.083 1-1/4 1.650 1.418 1-1/2 1.900 1.654 2 2.375 2.123 'Corrosion Resistance Ratio per latest UI Directory listing 1.00 1.461 1.860 70 1.00 2.070 2.754 51 1.00 2.547 3.468 44 1.00 3.308 4.842 30 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road chesterfield, MO Gerald, MO Kent WA Cats Grande AZ Dallas TX Masaty, OH - 63017 c®us LISTED <> APPROVED [;] A ONFSA NFPA' .—.— Bull Moose Tube's® EddyliteO is a lightwall threadable pipe manufactured in NPS 1' through 2". EddyliteO is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. EddyliteO is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED <> APPROVED [] 4 PJ!fA NFPA 6 ADVANTAGES OF BULL MOOSE TUBEO EDDVLITE Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. WATER BUNDLE FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 0.16 4.31 2.617 4.230 37 Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. A For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road J Chesterfield, MO Gerald, MO Kent WA Cans GrandR AZ Dallas TX Masury, OH 63017 Dull Moose Tube's Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® I) is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MlC preventative coating. economical to use than Schedule 10 due to reduced delivery costs -.---_- and ease of handling. Furthermore, NPS O.D. EDDY FLOWS EDDY FLOWZ WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR PER FT. WT. SIZE an opportunity for downsizing and further cost savings. 1-1/4 1.660 1.530 1.98 1.222 2.019 61 - 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 ' 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED APPROY I] 4 PJ!EA NFPA' For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA (ass Grand6 AZ Dallas, TX Masuty, OH 63017 7 Dull Moose Tubes® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® U a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NIPS O.D. ULTRA ULTRA EDDY® WEIGHT WATER BUNDLE (IN) (IN) EDDY® (ID) CRR°° PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 Pressfit is a Registered trademark of Victaulic company of America ** Corrosion Resistance Ratio per latest UL Directory Listing c®us LISTED APPROVED 1] 4 ON NFPA 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. !As <'f For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Coos Grande, AZ Dallas, TX Masuty, OH 63017 NPS(IN) 1 1-1/4 1-1/2 2 2-1/2 3 4 c®us LISTED 0.0(m) 1.315 1.660 1.900 2.375 I.D. 1.201 1.546 1.786 2.261 ULTRA EDDY' [ EmptyWeight(lb/ft) 0.868 1.107 1.274 1.604 Water Filled Weight (lb/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 1.660 1.900 2.375 2.875 3.500 4.500 LD.(in) - 1.530 1.728 2.203 2.705 3.334 4.310 EDDY FLOW' Empty Weight (lb/fl) 1.222 1.844 2.330 2.809 3.361 4.968 Water-Filled Weight (b/ft) 2.019 2.860 3.982 5.299 7.144 11.290 1.98 3.44 2.78 1.66 1.00 1.00 0.0(m) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 (•) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Eniptywemght(Ib/ft) 1 410 1 810 2090 2,640 3,130 4,140 5,620 10 Water li/ed Weight (lb/It) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R.1527 991 776 627 492 354 250 7 CO(in) 1.315 1.660 1.900 2.375 1.137 1.482 1.712 2.177 EDDYLITE' I Empty Weight(lb/ft) 1.260 1.617 1.967 2.617 Water-Filled Weight(Ib/It) 1.700 2.364 2.965 4.230 C.R.R. 0.13 0.08 0.12 0.16 1.295 1.650 1.900 2.375 EDDYTHREAD [ l.D.n) - 1.083 1.418 1.645 2.123 40 EmptyWeight(lb/ft) 1.461 2.070 2.547 3.308 Water-Riled Weight(lb/ft) 1.860 2.754 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 0Din) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 .0(m) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE Emptywemght(liiit 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water-Filled Weight (lbift) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. - , 1.00 1.00 1.00 1.00 1.00 1.00 1.00 C~3 A For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande, AZ Dallas, TX Masurt OH 63017 APPROVtD C;] 4 NFPA 4-1 c®us LISTED APPROVOI ORM NFPX --- 10 NIPS PIPE TYPE WEIGHT PER FOOT PIECES PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE WEIGHT PER BUNDLE ULTRA EDDY 0.868 91 1,659 1,896 1,975 SCHEDULE 10 1.410 91 2,695 3,079 3.208 1 EDDyLITEe 1.260 91 2,408 2,752 2,867 EDDYTHREAD-400 1461 70 2,148 2,454 2,557 SCHEDULE40 1.680 70 2,470 2,822 2.940 ULTRAED6Y0 1107 61 1,418 1,621 1,688 EDDYFLOW® 1222 61 1,565 1,789 1,864 SCHEDULE 10 1.810 61 2,319 2,650 2,760 11/4 EDDYLITE® 1.617 61 2,071 2,367 2,466 EDDYTHR-EAD 400 2.070 51 2.217 2,534 2,639 SCHEDULE 40 2.270 51 2,431 2.778 2,894 -: ULTRAEDDY® 1.274 61 1,632 1,865 1,943 EDDY FLOW® - 1.844 61 2,362 2,700 2,812 SCHEDULE10 2.090 61 2,677 3,060 3,187 1-1/2 EDDY LITE® 1.967 61 2,520 2,880 3,000 EDDYTHREAD40® 2.547 44 2,353 2,690 2,802 SCFIEDULE40 2.720 44 2,513 2,872 2,992 . ULTRA EDDY® 1.604 37 1,246 1,424 1,484 EDDY FLOW® 2.330 37 1,810 2,069 2,155 SCHEDULE 10 . 2.640 37 2,051 2,344 - 2,442 2 EDDYLITE® 2.617 37 2,033 2,324 2,421 EDDYTHREAD40 3.308 30 2,084 2,382 2,481 SCHEDULE 40 3.660 30 2,306 2,635 2.745 1-- - - 1 EDDY FLOW® 2.809 1,770 2,022 2,107 2-1/2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 SCHEDULE40 5.800 3,654 4,176 4,350 r EDDY FLOW® 3.361 1.341 1,533 1,596 3 SCHEDULE 10 4.340 ' 19 1,732 1,979 2,062 SCHEDULE 40* . 7.580 3,024 3.456 3,601 r1EDDY FLOW® 4.968 1,982 2,265 2.360 4 SCHEDIJIE10 5.620 19 2,242 2,563 2,670 SCHEDULE 40* SCHEDULE 10 10.800 9.289 10 4,309 1,951 4,925 2,229 5,130 2,322 8 lSCHEDULE1O 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande. AZ. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 BC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1 1544 1 12351 1012 1 867 1 726 40 1 40 1 40 1 40 1 40 37 34 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED <*> APPROVED U] A ONFM NFPA' A A For Additional Information Contact (800) 325-4467 www.bullmoosetube.com ('L) Or From Canada Call: (800) 882-4666 sales@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Casa Grande. Al Dallas, TX Masuiy, OH 63017 11 FireLock® Outlet-I ®< > IL PC- BI SEE VICTALJLIC PUBLICATION 10.01 FOR DETAILS STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1715, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 11/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para__________ Location Approved Date www.victaulic.com '\.Actaulid vicTAuLic IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. 02009 viclAuLic COMPANY. ALL RIGHTS RESERVED. REV_G 10.521 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I STYLE 922 DIMENSIONS V . z El if-----it 1218 110 387 650 0.54 1 1/2 1/2 1 1.42 1.95 1.22 4.08 2.56 1.2 40 15 30.2 36.1 1 49.5 31.0 + 103.6 65.0 0.54 3/4 1 3/ 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 1 13/16 1.64 2.30 1.22 4.08 t 2.56 1.3 25 30.2 41.7 - 58.4 31.0 103.6 65.0 0.59 2 1/2 1 1.66 2.19 1.46 4.60 1 2.56 1.3 50 15 30.2 42.2 55.6 37.1 116.8 65.0 - 0.59 3/4 13/16 T 1.64 2.19 1.46 1 4.60 l 2.56 1.4 20 30.2 41.7 55.6 37.1 116.8 65.0 0.64 1 13/16 1.88 2.54 1.46 i 4.60 2.56 1.5 25 - 30.2 47.8 64.5 - - 371 116.8 65.0 0.68 2½ x ½ 1/a f 1.91 2.44 1.71 5.40 2.56 - 1.6 65 15 30.2 48.5 62.0 - 43.4 137.2 65.0 0.73 3/4 13A6 1.89 2.44 1.71 5.40 2.56 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1- 1 13A6 2.13 2.79 1.71 5.40 2.56 - 1.6 25 30.2 54.1 70.9 43.4 137.2 65.0 0.73 ½ 1 3/ 1.91 2.44 1.71 5.50 2.56 1.6 76.1 mm X 15 30.2 48.5 62.0 43.4 139.7 650 0.73 4 - --- 34 13/16 1.89 2.44 1.71 . 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 4 65.0 0.73 1 13/16 2.13 f 2.79 1 1.71 1 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 139.7 65.0 0,80 t Victaulic female threaded products are designed to accommodate standard NFl or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. Q 2009 vICTAuLIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 \%taulicr REVG IRS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-I STYLE 922 PERFORMANCE Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. ictaulic REVG 10.523 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 ictaulic VICTALIC IS REGISTERED TRADEMARK OF VIcTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings SMITH,.-COOPEW INTERNATIONAL Ductile Iron Threaded Fittings Specifications branded ductile r0n threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP cULus Ductile iron castings conform to ASTM A53 LISTED Fitting dimensions conform to ASME 1316.3 o Bushings and plugs conorrn to ASME B16.14 FM <S> Fittings are 100% air tes:ed APPROVED NPT threads on ai fittings conform to ASME B1.:20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 140DI Temerature Working Pressure, Nonshock psiG Derces F 300# Class Threaed Fittings 20 3 100 153 203 250 503 500 480 460 300 440 -- 350 420 463 L50 530 550 280 360: 340: 620 650 320 300 Fig. 35E3-90° Elbow c®US <Z> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 35E 3006 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E 3012 1.75 25 50 0.8 1-1/2 35E3014 1.94 18 36 1.1 2 10 20 1.8 35E 3020 2.25 2-1/2 35E 3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 35RE3010004 1.20 1.22 80 70 50 35 35 30 30 25 20 18 18 160 0.3 0.4 0.4 0.5 0.6 0.7 0.6 0.7 0.8 1.0 1.0 lx 1/2 1 x 3/4 1.26 1.36 1.45 1.53 - 1.63 1.67 1.75 140 100 70 70 60 60 50 35RE3010006 35RE3012004 1.38 1.34 1.45 1-1/4 x 1/2 1-1/4x 1-1/4x1 1-1/2x 1/2 1-1/2x314 E3 3/4 35RE3012006 35R012010 35RE3014004 1.58 1.52 35RE3014006 35RE3014010 35RE3014012 35RE3020004 1.52 1.75 1-1/2x1 1-1/2x1-1/4 1.65 1.82 1.80 1.88 1.97 40 36 36 2x1/2 1.60 2x3/4 2x1 35RE3020006 3E3020010 5R 35RE3020012 1.60 1.73 1.90 - 2.02 2.16 2.39 1.97 2.02 18 16 36 32 24 1.0 1.2 1.3 2x1-1/4 - 2.10 12 10 6 6 2x1-1/2 2-112 x 1-1/2 2-1/2 x 2 35RE3020014 35RE3024014 - 2.16 2.51 20 1.5 2.2 2.5 12 12 35RE3024020 2.60 JA Fig. 35F 3_450 Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 35F 3004 35F 3006 35F 3010 0.88 150 300 160 80 0.2 0.3 0.5 0.98 1.13 1.29 1.44 - 1.69 1.95 80 40 25 1-1/4 1-1/2 2 2-1/2 35F3012 50 40 20 0.7 1.0 1.6 2.7 35F3014 35F 3020 20 10 35F 3024 4 8 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 3513004 35T3006 1.13 1.31 80 30 160 60 0.3 0.5 0.7 1.1 1.5 2.4 4.3 1 1-1/4 35T 3010 35T3012 1.50 1.75 1.94 25 50 20 20 10 10 1-1/2 35T3014 - 2 -. 2-1/2 35T 3020 3513024 2.25 6 4 12 8 2.70 111 SMITH-COOPER INTERNATIONALA • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner IMaster 3/4x 1/2 1x1/2 lxl/2x1 1 x 3/4 1 x3/4x3/4 1x3/4 x1 1-1/4x1/2 1-1/4x1/2x1-1/4 1-1/4x3/4 l-1/4 x3/4x1-1/4 1-1/4x1 1-1 /4xlxl/2 1-1/4 x1 x 3/4 i-1/4x lxi 35RT3006004 35RT3010004 35RT3010004010 1.20 1.20 _T.26 1.22 1.36 1.50 1.45 1.45 1.50 1.53 1.75 1.62 1.75 1.67 1.53 1.63 60 30 30 25 35 25 20 25 15 20 15 25 20 20 120 60 60 50 70 50 40 50 30 40 30 50 40 40 0.4 0.6 0.6 0.6 0.6 0.7 0.8 0.9 0.9 1.0 1.0 0.7 0.8 0.9 1.26 1.50 1.36 1.38 35R13010006 1.38 35RT3010006006 35RT3010006010 35RT3012004 1.38 1.31 1.45 1.50 1.34 1.75 1.45 1.75 1.34 1.53 1.45 1.62 1.58 1.26 1.38 35RT3012004012 35RT3012006 35RT3012006012 35RT3012010 1.58 35RT3012010004 1.34 35RT3012010006 1.45 35RT3012010010 1.58 1.50 1.69 1-1l4x1x1-1/4 i-1/2x1/2 1-1/2x1/2x1-1/4 35RT3012010012 1.75 1.41 1.69 1.41 1.56 1.75 1.66 1.88 1.94 1.75 1.88 15 16 24 12 16 20 30 32 48 1.0 1.0 1.1 35RT3014004 35RT3014004012 1.81 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 24 1.2 1.1 1.1 1-1/2x 3/4 1-1/2x3/4x1-1/4 35RT3014006 1.52 1.52 32 35RT3014006012 1.94 1.66 40 1-1/2x3/4 x1-1/2 35RT3014006014 1.94 1.75 1.65 1.25 1.94 1.80 1.69 1.75 18 12 20 36 24 40 1.2 1.2 0.8 -0. 9 1.0 1.2 1-1/2x1 35RT3014010 35RT3014010004 1.65 1.44 i-1/2x1 x1/2 1-1/2x1x3/4 35RT3014010006 1.50 1.44 16 32 1-1/2x1x1 1-1/2x1 x1-1/4 35RT3014010010 1.65 1.50 1.80 16 32 35RT3014010012 1.82 1.67 1.88 12 12 12 16 - 16 16 14 14 10 10 8 8 8 24 1-1/2x1x1-1/2 1-1/2x1-1/4 35R13014010014 1.94 1.80 1.94 1.88 24 24 32 1.3 1.4 - 0.9 1.0 1.1 1.3 1.4 1.6 1.7 1.9 1.9 201.5 35RT3014012 1.82 1.82 1-1/2x1-1/4x3/4 1-1/2x 1-1/4x 1/235RT3014012004 35RT3014012006 1.41 1.34 1.66 1.75 1.80 1.88 1.52 1.45 32 32 28 28 20 16 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1-1/2x 1-1/4x 1-1/2 2x 1/2 2x3/4 2x1 2 x 1 x2 2x1-1/4 35R13014012014 35RT3020004 1.94 1.49 1.88 1.49 1.94 1.88 1.97 2.02 2.25 2.10 35RT3020006 35RT3020010 1.60 1.60 1.73 1.73 35RT3020010020 2.25 2.02 16 16 35RT3020012 1.90 1.90 2x1-1/4 x2 2x1-1/2 35R13020012020 35RT3020014 2.25 2.10 2.02 2.25 2.16 8 8 16 16 2.0 2.1 2.02 2x1-1/2x1/2 2x1-1/2x3/4 35R13020014004 1.49 1.60 1.41 1.52 1.88 1.97 10 10 8 8 8 20 20 16 16 16 1.3 1.4 1.5 1.7 1.8 35RT3020014006 2x1-1/2x1 2x1-1/2x1-1/4 35RT3020014010 1.73 1.65 1.82 2.02 -2. 1-0 35813020014012 1.90 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 I APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Hew! Tee Size in Part Number a u er A in B in C in Packing Weight lb Inner Master 3/4x1 ix 1-1/4 35BT3006010 1.45 1.45 1.67 1.37 1.58 30 20 60 40 0.6 0.9 35B13010012 1.67 1 x 1-1/2 1-1/4x1x1-1/2 35BT3010014 35BT3012010014 1.80 1.80 1.80 1.65 1.82 15 15 15 - - 10 10 8 30 30 30 20 20 16 1.0 - 1.2 - 1.3 1.6 1.8 1.8 1.88 1-1/4x1-1/2 1-1!4x2 35B13012014 35BT3012020 1.88 1.88 - 1.82 2.10 2.10 1.90 1-1/2x1-1/4x2 1-1/2x2 35BT3014012020 2.16 2.10 2.02 2.02 35BT3014020 2.16 2.16 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Size Part Number A Packing Weight Inner Master in in lb 1 x 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4x3/4 35RC3012006 35RC3020010 2.06 40 80 40 0.6 I 1.0 2x 1 (not hex)l 2.81 20 Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 1 1-1/4 1-1/2 2 35SP3004 35SP3006 35SP3010 35SP3012 35SP3014 0.94 1.12 600 350 1200 700 400 - 0.07 0.1 0.1 0.3 0.4 0.6 1.25 1.37 200 - 100 80 45 200 160 90 1.44 35SP3020 1.50 ceus APPROVED A Fig. 35CP3 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1.75 1 35CP3010 60 120 0.4 1-1/4 35CP3012 2.00 70 0.5 35 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 1 3.00 9 2-1/2 35CP3024 18 2.2 Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 -Hex Bushing Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1 x3/4 1-1/4 x1 35HB3010004 35HB3010006 1.06 1.06 180 360 0.2 0.1 0.2 180 360 180 35HB3012010 1.19 90 - 1-1/2 x 1 1-1/2 x 1-1/4 2 x 1 35HB3014010 1.25 75 75 40 150 150 80 0.4 0.3 0.6 35H83014012 35HB3020010 1.25 1.38 2x1-1/4 2x1-1/2 35HB3020012 35HB3020014 1.38 1.38 40 40 80 80 0.6 0.6 Fig. 35SP3 - Square Head Plug Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 1-1/2 35U3010 35U 3012 35U 3014 2.19 20 15 10 40 30 20 1.0 1.2 1.7 2.50 2.62 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 01 A Size in Part Number A in Packing Weight lb Inner Master 1 1-1/4 1-1/2 2 35X 3010 1.50 1.75 20 12 8 6 40 24 16 12 0.9 1.4 1.8 2.8 35X3012 35X3014 35X 3020 1.94 2.25 Size in Part Number A in Packing Weight lb Inner Master 1/2 3503004 0.87 300 600 0.1 - 0.1 0.2 0.4 0.5 - 0.8 3/4 - 35C 3006 35C3010 0.97 1.16 1.28 200 110 70 50 400 220 140 100 1 1-1/4 1-1/2 2 2-1/2 3503012 3503014 35C 3020 35C 3024 1.33 1.45 25 18 50 36 1.70 1.6 Fig. 35BC3 - Beam Clamp c©us <e> APPROVED A A Fig. 35X 3- Cross LISTED Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner Master 1-1/4x1 1-1/2x1 2 x 1 35RX3012010 1.67 1.58 1.65 1.73 15 12 8 30 24 16 1.2 1.4 2.0 35RX3014010 1.80 35RX3020010 2.02 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 3/8 35B03003 0.75 100 200 0.3 1/2 35B03004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smichcooper.com 114 INSTALLATION STEPS - '!Lfl INTO WOOD & STEEL: I LNSTALLATION STEPS - I1iib INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS* into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4°, 3/8', 1/2' or metric all thread rod, bolt stock. (The 1/2' requires the #I4SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8'or 1/2" portable drill. Insert the SAMMYS into the #I4SW (red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4', 3/8', Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in purlin steel. iIIifl'II1I INSTALLATION STEPS -!JIjIi, INTO CONCRETE: 1 Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre -drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the 414 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre.-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2' or metric all thread rod or bolt stock. (#14SWred nut driver used with 1/2' screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS -I1Th®LINTO CONCRETE:] Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8'or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. N1106M gmm kii11IIli 1i! 0-,psUlliilI1lfr'Ilia SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driverfor installations. f Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. Watch a video demonstration at www.ilwbulldex.com SAMMYS FOR STEEL 1/4" 8024957 DSTR 100 • 1/4-20 xl" TEKS 3 1510 (20 ga.) .036"-20 ga 3/16" 25 125 1/4 8025957 DST 100 1/414x1 TEKS3 446 (20 ga.) .036"-2o ga 3/16 25 125 1/4" 8026957 DST 150 I/4-14x1-1/2"TEKS3 970 (16 ga.) .036"-20 ga 3/16" 25 125 - 1/4 8027957 DST 200 1/414x2 TEKS3 446 (20 ga) - - 036 2004 3/16 25 125 1/4 8030957 TEKSOO 1224x1-1 /2 TEKS5 3125 (3/16) .188"-3/16" 1/2 25 125 3/8w 8038957 OSTR1 • 1/4-20x1" TEKS 3 1510 (20 ga.) 1500 1475 .036"-20g0 3/16" 25 125 " 3/8" 8037957 DSTR 1-1/2 • 12-24 x 1-1/2" TEKS 5 1510 (3/16") 1500 1475 .060"-16 ga. 1/2 25 125 #14 Black 3/8" 8039957 DSTR 516 * 5/16-18 x 1-1/4"TEKS 3 2200 (2o ga.) 1500 1475 .036"-20ga 3/16" 25 125 Nut Driver Part 3/8" - 8040957 DST 10 114-14 x 1"TEKS 3 446 (20 - 036"-20 ga 3/16" 25 125 3/8 8077925 DST 10-SS 1/4-14 xl" TEKS 3 446 (20 .036-20 ga 3/16" 25 125 3/8" 8041957 DST 15 1/4-14x1-1/2" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8078925 DST 115-SS 1/4-14 x 1-1/2"TEKS 3 446 (20 .036"-209a 3/16" 25 125 3/8" 8042957 DST 20 1/4-14x2" TEKS 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8043957 DST 25 1/4-14x2-1/2"TEKS3 446 (20 ga.) .036"-20 ga 3/16" 25 125 970 (16 ga.) 3/8" 8044957 DST 30 1/4-14 a 3" TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 3/8.8045957 —DST 516 5/16-18x1 1/4TEKS3 1500 (3/16) 1500 1475 .125"-1/8" 3/16 25 125 3/8" 8046957 TEKSO 12-24x1-1/2TEKS5 3125 (3/16) 1500 1475 .250-1/4" 1/2" 25 125 - • 1/2" 8031925 DST 2.0 1/4-14x2"TEKS3 446 (20 .188"-3/16 1/4" 25 125 1/2 8033925 DSTR 10 1/420 xl TEKS 3 1510 (20 ga) .036"-20 ga 3/16 25 125 1/2 8034925 DSTR516 5/16-1.8.x 1 1/4 TEKS3 2220 Q0 ga) .036'-20 ga 3/16 25 125 I 1/2" 8035925 DST 5.16 5/16-18x1-1/4" TEKS 3 1500 (3/16") .125"-1/8" 3/16" 25 125 #14SWRed L 1/2" 8036925 TEK5.O 12-24x1-l/2" _TEKS 5 3125 (3116") .188"-3/1 1/2" 25 125 NutDnver _.••••••••• _.••.- Part #8114910 *Includes retaining nut Y SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins WOE u.s free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. ~ SS N M, TTAYfs° Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2" thicknesses. "10 A standard screwgun with a depth sensitive nosepiece should be used to c e qt.t e ci install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Made in the U.S.A. V9.1 V VIWW!IWbUlldX.COfl1J 1/4" 8047957 SWO 100 1/4-14x1"TEKS3 1477 (16ga.) .060'-16 ga 3/16" 25 125 1/4 8049957 SWDR lOU 1/420 xl TEKS 3 1900 (20 ga) .036"-20 ga 3/16 25 125 3/8" 8050957 SWO 10 1/4-14 Xl" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16° 25 125 3/8 8080925 SWDIOSS 1/414x1 TEKS3 1477 (169a) .060"-16 ga 3/16 25 125 3/8" 8051957 SAID 15 1/4-14 x 1-1 /2" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16° 25 125 3/8.8052957 SWD20 114-14 x TTEKS3 1477 (16 ga.) .060"-16 ga 3/16 25 125 3/8" 8053957 SAID 516 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga.) .036"-20 ga 3/16 25 125 JE.°° 3/8 8055957 SWDR 1 11420 xl TEKS 3 1900 (20 ga) 1500 1475 .036"-20 ga 3/16 25 125 #14 SW Red <8> 3/8° 8054957 SWDR 1-1/2 * 12-24 x 1-1/2"TEKS 5 2375 (3116") 1500 1475 .188"-3/16° 1/2" 25 125 Nut Driver S" 318" 8056957 SWDR 51 1. 6 5/16-18 x 1-1/4"TEKS 3 2480 (20 ga:) 1500 - 1475 .036"_-20 ga 3/16" 25 - 125 Part #8114910 - 3/8" 8057957 SWT15 12-24x1-1/2°TEKS5 2375(3/16") .188"-3!16" 1/2" 25 125 - "Includes retaining nut "Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. Installs into angled z-purlin; allows threaded rod to hang plumb. AJIows 17° deflection from vertical. 'Made in the U.S.A. Watch a video demonstration at www.itwbulldex.com #14 Black Nut Driver — Part # 8113910 j 3/8" 8268957 SH-TEK 50 r!J I 1/2" 8270957 SH-TEK5.O 12-24x1-3/4' #14SHOrange j Nut Driver Part #8273910 'Does not comply with ROHS requirements/Includes retaining nut 2368(1/2" steel Vertical) 1306(45° off Vertical) 2281 (3/16" HSS) 1585(3/16" HSS 45" off Vertical) 2368(1/2° steel Vertical) 1306(45° off Vertical) 2281 (3/16" HSS) 1585(3/16" HSS 45° off Vertical) 1500 (Vertical) 4' 3/16" 1/2" 25 125 850(45" off Vertical) 2-1/2" 3/16" 1/2" 25 125 I S A 1141111 V X-P R E S 5® Installs into Metal Deck, Purlin, or Tubular Steel j The Sammy X-Press expands to provide direct vertical attachment in: - light gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press It® Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. WI Watch a vfdeo dt®ho\ www.itwbuildex.co 8181922 XP 200 Sammy1146 (22 ga) 185 (Luminaire) .125' 25 125 Metal Deck X-Press 200 250 (Luminlire) 850(2%" Pipe) .027' 940 (2" Pipe) 029" 3/8" 8150922 XP 20 Sammy1146(22ga) 185 (Luminalre) .027" 1475 (4" Pipe) :104" .125' 25 125 Metal Deck X-Press 20 250 (Luminaire) .056' 283 (Conduit & Cable) .029" 1500(4" Pipe) .060' 3/8" 8153922 XP 35 Sammy 1783(16 ga) 185 (Luminaire) .029 :: .125' 25 125 Pudin x- 250 (Luminaire) P) :104: 416 (Conduit & Cable) .059" Pre-Pour Structural Concrete@ 3000 PSI Metal Deck 3/8" 8150922 XP 20 Sammy1146 (22 ga) 850 (2% Pipe) 25 125 Metal Deck I X-PI r ®s 20 Post-Pour Range It LWC 35 PCF (lbsin (Pt-Pour) Pre-Pour Structural Concrete @ 3000 psi Post-Pour Range II LWcS 35 PCF (Ibs! ft') The Sidewinder expands to provide "Less jobsite material needed. horizontal attachment in: - 16 ga - 3/16" steel- puriin, tubular steel. No retaining nut required. 02- 'Installs in seconds with Sammy X-Press It® Tool, "Provides design flexibility. " saving time & installation costs. Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof Watch a vde ,jenonstratun' deck, tubular steel, or vapor barrier fabric. /.. 3!8" 8293957 SWXP 35 1798 (16 ga) 80 (Luminaire) .059' .125" 25 125 Pudin - X- Press _416 (Conduit & Cable) MWSi The Swivel X-Press allows you to hang plumb in extreme roof pitches: - 89° in z-putiin - 45° in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press It0 Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor baffler fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Wafch a video demonstration at www.ftwbuildex.com 750(2" Pipe) 3/8" 8294922 SXP2O Swivel 1061 (22gaVert) 170 Vertical (Luminaire) 80@45°(Luminaire) .029" 635 (2' Pipe) .029" .125" 25 125 Metal Deck X-Press 20 829 (450 Off Veil) 283 Vertical (Conduit & Cable) 233 @45" (Conduit & Cable) 1250 (3-1/2" Pipe) *i 3/8" 8295922 SXP35 Swivel 1675(16gaVerl) 250 Vertical (Luminaire) 80@90"(Luminaire) .029" .125" 25 125 Pullin X-Press 35 1558(89" Off Vert) .059" 635 (2" Pipe) 500 Vertical (Conduit & Cable) 333 @89" (Conduit & Cable) 1/2' 8272957 SXP 2.0 Swivel X-Press 2.0 1061(2290 Veil) 829 (45" Off Veil) .027' .125" 25 125 Metal Deck 1/2" 8271957 SXP3.5 Swivel 1675(1690 Veil) X-Press 3.5 1558(89° Off Vert) .069" .125" 25 125 Puilin r /\i "The Sammy X.Press expands to provide metal deck (22-16 gauge) (e z-purlin (18-16 gauge) Made in the 1 Watch a video demonstratIon - . .. www.iiwbulldex.comJ 8194910 UXPIT" Universa!X-Press it Tool 8152910 XPDB 25/64 Drill Bit 'Tool Includes: Sleeve, Bit Receiver, Hen bWenclr, and 25/64" Dill Bit APPROVALS 8007957 GST 10 3/8" Vertical CPVC 1-1/2" 300 1-1/2" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2" 8008957 GST2O 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 GST2O-SS 3/8" Vertical 2-1/2" 850 1-1/2" 8010957 GST3O 3/8 Vertical 4' 1500 1-1/2" 4" 1475 1-1/2" 8009925 GST25-380 3/8" Vertical 4" 1500 1-112" 8022925 SWG 25-380 3/8" Horizontal 3-1/2" - 4'* 1500 1-1/2" 8021957 SWG 20 3/8" Horizontal 2-1/2"-3""° 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45° Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CSI2O 3/8" 45" Angle off Vertical 4" 1500 1-1/2° 8139957 SH-GST20 3/8" 17° Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2° I 0l0f&.1I11F[c11 mammm M&M I 8038957 DSTR 1 3/8' Vertical 1500 .035" 4" 1475 .105' 8037957 DSTR 1-1/2 3/8" Vertical 4" 1500 .035" 4" 1475 .105' 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188' 8046957 TEK50 3/8' Vertical 4" 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 3/8' Horizontal 4' 1500 .037" 4' 1475 .060" 8054957 SWDR 1-1/2 3/8' Horizontal 4" 1500 .037" 4" 1475 .060° 8137957 SH-DSTR1 3/8" 17° Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268957 SH-TEK5O 3/8" Vertical 2-1/2" 850 70° Angle off Vertical 4" 1500 8150922 XP 20 3/8" Vertical 2-1/2" 850 .027" 4" 1475 105' 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4" 1475 8294922 SXP 20 3/8° Vertical or up to 45° 2" 750 .027" 2" 635 .029" 8295922 SXP 35 3/8" Vertical orupto89° 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP35 318" Hedzontal 3-1/2' 1250 .060" SAMMYS FOR CONCRETE - PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3900 8061957 SWC2O 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8° Vertical 2-1/2" 850 Pre-Pour Structural © 3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Range II LWC r 35 PCF (lbs/ft3) 185 .027" 8150922 XP 20 3/8" Vertical 250 .035" 8153922 XP 35 3/8" Vertical 185 .027" 250 .035" 185 .027" 8181922 XP 200 1/4" Vertical 250 .035" Vertical 170 .027" 8294922 SXP 20 3/8" 45" 80 .027" Vertical 250 .060" 8295922 SXP 35 3/8" 90" 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" 8150922 XP 20 318" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8153922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060' Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP35 3/8" Horizontai 500 .060" Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4° or 3/8" Onto Vertical Rod UL Listed 4S16 - Cable Hanger, Cat No. C12000 Plenum Rated, Qheet Steel Gauges Complies w/ NEC Standards Gauge No. 22ga. 20ga. 18ga. 16ga. 14ga. 12ga. 1/8" 3116" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250° SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4 UL and FM tests were performed in compliance with NFPA 13 Standards. "SWG 20 Maximum pipe size in composite wood joist allowed bytJL 152-112° Fastening requirement: 5 times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installation, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist. Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: ______ Model ___________Root __Diameter __________Hole _Size: GST 20 .182" 1/8" GST 25-380 .280" 7/32" SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com PIPE HMIGE# .1soLmmoAscG,munMC.LuK.pwafl IEEE LWEDA3MtCEEEU$NIiP Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made In the U.S.A.Products _ Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description 3.3.7.1 Product description KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.37.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACt 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. Listings/Approvals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor MA(D S <*> APPBWM IndeDendent code evaluation IBC®/ IRC® 2015 IBC®/ lRC® 2012 lBC®/ lRC® 2009 IBC®/ IRC®2006 Hilti, Inc. (US) 1-800.879-8000 1 www.us.hilti.com I en español 1.800.879-5000 1 Huh (Canada) Corp. 1.800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Figure 1 - KWIK HUS-EZ I anchor installation details Table 1 - Hilti KWIK HUS-EZ I specifications',' Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter db, in. 1/4 Nominal embedment hnom in. 1-5/8 2-1/2 Effective embedment h, in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T inst ft-lb (Nm) 18 (24) Wrench size in. 7/16 1 T551 is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters wrench size 'da - 1 13flch , - h hnom - h0 Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 93,4,5 Nominal Nominal Tension - cpN Shear - On anchor embed. f' = 2,500 psi f' = 3,000 psi f' = 4,000 psi f' = 6,000 psi f' = 2,500 psi f' = 3,000 psi f, = 4,000 psi f, = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 1/4 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2,3,4,5 Nominal Nominal Tension - Shear - anchor embed. f'c = 2,500 psi f, = 3,000 psi f = 4,000 psi f' = 6,000 psi f, = 2,500 psi f'c = 3,000 psi f' = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) 1 / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) See section 3.1.8.6 to convert design strength value to ASD value. Linear interpolation between embedment depths and concrete compressive strengths is not permitted. Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, X. = 0.68; for all-lightweight, ) = 0.60 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNS = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors',' Nominal anchor Nominal internal Tensile3 Shear' Seismic shear' diameter thread diameter in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 UNC (16.4) (3.6) (1.6) 1/4 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASO value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension qN = (PA.., f.. as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with <0.64A50, f515 as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with :5 (P 0.60 A 5 f as noted in AOl 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Huh (Canada) Corp. 1.800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete1'2 Edge distance in shear (Ito and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear3 uncracked concrete f. fRN 1AV fRy fRV 'HV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h 3 (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a ij 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 _______ 1.00 0.68 0.62 1.00 0.60 _______ 1.00 n/a n/a g 3-1/4 (83) 0.96 0.78 _______ ________ 0.70 0.63 0.68 0.88 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 g 5 (127) 0.93 0.80 1 0.70 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 CZ 10 (254) 0.89 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete' 2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear' I toward edge from edge factor in shear3 cracked concrete f I RN 1AV 11V 'RV .fHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 1 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 CO 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 CO 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 10(254) 0.90 11(279) 0.94 12(305) 0.98 14(356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROMS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, f A, assumes an influence of a nearby edge. If no edge exists, then I AV = IAN 4 Concrete thickness reduction factor in shear, fHv assumes an influence of a nearby edge. If no edge exists, then fHV = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation inupper flute Nominal Nominal NominalTension - 4N Shear - Tension -(pN Shear - On internal anchor thread embed. f,= 3,000 psif'= 4,000 psif= 3,000 psif,,= 4,000 psif= 3,000 psif'= 4,000 psif 0= 3,000 psi '= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck 1'2'3'4'56'7'8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - 4N Shear - Tension - 4N Shear - 4V anchor thread embed. f'= 3,000 psif= 4,000 psif'= 3,000 psif= 4,000 psif= 3,000 psif= 4,000 psif= 3,000 psif'= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 ______ (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1/4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by a N,Wis = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - 0V,ejs = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. us 1-800-879-8000 1 www.us.hiiti.com I en españoi 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies min. 3/4' - , - - 'I . -' Mm. 3,000 psi sand-lightweight1 or normal -weight concrete CO flute ' Min. 4-1/2" Minimum TAnchor/ (typical) 20 gauge steel deck \L Lower Flute edge _J flute (typical) i Mm. 1-1/4" __...j Mm. 12' (typical) (ridge) - 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. - II 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile3 Shear4 Shear' diameter diameter N r V r V req in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N = A N q R as noted in GSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V, < A,4 4 0.6 f R as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with V 4 <A04 4 0.6 f R as noted in GSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 AnchorO.D. da in. 1/4 (mm) (6.4) Effective embedment2 h el in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment' 2-1/2 h nom in. 1-5/8 (mm) (41) (64) 4-1/8 in. 3-1/4 Minimum concrete thickness h min (mm) (83) (105) Critical edge distance c3 in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance S ncac in. 1.5 (mm) (38) Minimum edge distance Cmin in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) in. 2 I 2-7/8 Mininimum hole depth in concrete h0 (mm) (51) () Minimum specified ultimate strength futa psi 125,000 (N/mm') (862) in 0.045 Effective tensile stress area A seN (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3,370 Factored steel resistance in tension N D.6.1.2 (kN) (15.0) lb 750 Factored steel resistance in shear V55, D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V req (kN) (1.5) lb 725 Factored steel resistance in shear Vear D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic (kN) (2.8) Cbeff. for factored conc. breakout resistance, uncracked concrete kCCflC, - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete kC Cr - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 qJ - 1.0 D.6.2.6 Anchor category - - 3 1 1 D.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 lb 665 1,645D.6.3.2 Factored pullout resistance in 20 MPa uncracked concrete Npruncr (kN) (3.0) (7.3) lb 340 815 Factored pullout resistance in 20 MPa cracked concrete Nprcr D.6.3.2 (kN) (1.5) (3.6) 275 815 Factored seismic pullout resistance in 20 MPa cracked concrete Nprw (lb kN) (3.6) (1.2) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section D.2. For all design cases, tp5 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (kccr) or uncracked concrete (kcnc) must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, tp5 = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (us) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in uncracked concrete 1,2,3,4,5 Nominal __________ Tension - Nr Shear - V, f' = 20 MPa f'c = 25 MPa f 30 MPa f'c = 40 MPa f = 20 MPa f' = 25 MPa I = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concrete1'23'45 Nominal Tension - Nr Shear - V __________ f' = 20 MPa f' = 25 MPa 1',, = 30 MPa f' = 40 MPa f' = 20 MPa f = 25 MPa f' = 30 MPa f' = 40 MPa anchor Effective Nominal diameter embed, embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by Aa as follows: for sand-lightweight, Aa = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - mm = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879.8000 1 www.us.hilti.com I en español 1.800-879-5000 1 Huh (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2.3,4,5,6,7 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - N Shear - Vr Tension - N Shear - V anchor thread embed. I = 20 MPa I = 30 MPa I = 20 MPa I' = 30 MPa f, = 20 MPa f, = 30 MPa f, = 20 MPa I', = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck" 2'3'4'5'6'18 II Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear - Vr Tension - N, Shear - V, anchor thread embed. I = 20 MPa I = 30 MPa IC = 20 MPa f'C = 30 MPa f' = 20 MPa f, = 30 MPa f'c = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h,0,, (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,oeo = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - 0.45 For the 1/42-1/2 anchor - 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Mm. effective embedment het in. Allowable load Ultimate load Tension lb Shear lb45 Tension lb Shear lb 4,5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Description diameter KH-EZ 1/4x1-5/8 11/4 1/4 KH-EZ 1/4x2-1/2 11/4 1/4 KH-EZ 1/4x1-5/8 13/8 3/8 KH-EZ 1/4x2-1/2 13/8 3/8 1 All dimensions in inches. Internal thread Hole Minimum length diameter embedment Qty/ box 3/8 1/4 1-5/8 100 3/8 1/4 2-1/2 100 7/16 1/4 1-5/8 100 7/16 1/4 2-1/2 100 Hilti, Inc. (US) 1-800.879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiltica I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/ie 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 1/16 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved c Seismic Restraints System US LISTED Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects. please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • P11: 951.737.5599 • FAX: 951.737.0330 .1 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer C® US LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electra-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of Seismic Restraints System US USTED California OSHPD Approved c Size Range - Secures 3/8' thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish — Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 OFFICE/MANUFACTURING FACILITY • 1315 SAMPSON AVE. . CORONA, CA 92879 PH 9517375599 . FAX: 951.137.0330 CUSTOMER SERVICE • 800.186.5266 www.tofco.com B -1-- A Fig. 200-/2. 200-/4 Fig. 200-1 to 200-2 Fig. 200_2112 to 200-8 Fig. 200 Fig. 200F Fig. 200S Wit Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) ØTOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170INFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut C® US LISTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171E & A-A-1192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. Fig. 200C 200_1/2 /2" (15) /8"-16 31/8 ' (79.4) 2/8" (66.7) 11 (5.0) 200-/4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/8" (85.7) 2/8' (66.7) 12 (5.5) 200-11I4 1/4" (32) /8"-16 33/4" (94.0) 2/8' (73.0) 13 (5.9) 200-1I2 11/2" (40) /8"-16 3 /8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 2' (50) /8"-16 41/2' (114.3) 3" (76.3) 15 (6.9) 200_2112 21/2" (65) /8"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-3/2 31/2" (90) /8"-16 7/8" (187.3) 51/4' (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6' (150) 1/2"..13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8' (200) 1/2"..13 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. I 01 COOPER B-Line Fig. 200-1 to 200-2 Fig. 200_112. 200-/4 Fig. 200_2112 to 200-8 'DLCO c®uS LISTED Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved /4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM OS 2-0. S: m 200M8-1/2 1/2" (15) MO 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4° (20) MO 31/8' (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4° (20) M10 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200M8-1 1° (25) M8 3I8" (85.7) 25/8 (66.7) 12 (5.5) 200M1 -1 1° (25) M10 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-1112 11/2" (40) MO 3I8" (98.4) 2/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3/8" (98.4) 2/8" (73.0) 14 (6.4) 2001Y18-2 2° (50) MO 4/2" (114.3) 3" (76.3) 15 (6.9) 200M10-2 2° (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2" (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3" (75) MiO 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 41' (100) M10 7/8" (187.3) 5' (127.0) 35 (16.0) 200M-5 5" (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 611 (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 1 8" 1 (200) 1 M12 131/8" (333.4) 1 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8'-16 or 1/2°..13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. ITt.J.u1.i.I C @ us LISTED IIIIIIIIIIII - ( .. 200H-2-3/8 2' (50) /8-16 4/16' (115.9) 3/32 (81.7) 48 (21.8) 200H-2-1/2 2" (50) 1/2"_13 423/32' (119.8) 3/8' (85.7) 45 (20.4) 200H-21/2-3/8 21/2' (65) /8"-16 5/16' (134.9) 323/32 (94.4) 59 (26.7) 200H-21/2-1/2 21/2 (65) /2"13 5/32' (138.9) 3/8 (98,3) 56 (25.4) 200H-3-3/8 3' (75) /8"-16 53/4" (146.0) 327/32° (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2"..13 5/8" (148.1) 331/32' (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6I8" (174.6) 4/16" (112.7) 76 (34.5) 200H-4-1/2 4" 1 (100) 1/2"_13 71/32" (178.6) 1 419/32" (1116.7) 73 1 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8' pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. .... .. ... COOPER B-Line P!Ga!eiLu Mill b!! WK TCNL F PP I® Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFitO can be easily applied in temperatures from -10°F to 150°E LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -10° to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ" System Compatible Program* Certified to NSF/ANS/Std 61 -G MCK SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, ti ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 WU © 2012 Fire Protection Products, Inc. FPPI°, LubeFit° are registered trademarks of Fire Protection Products, Inc. FGG/BM/CZ', Blaze-Master's, FlowGuard Go/cF and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. J=WwW%;P,1P,11!U-_uM PipeFi Thread Sealing Paste F] M Loh F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. F 0 so ~bfl SYSTEM COMPATIBLE *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 32 02. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com wu LA MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPPf5, LubeFit5 are registered trademarks of Fire Protection Products, Inc. FBC", BlazeMaster, FlowGuard Gold5 and Co,zan® are registered trademarks of Noveon IP Holdings Corp. Spears® Compatible indicates that Thread Fit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. I FJ lnlg I F P P I Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cuffing oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. wu © 2013 Fire Protection Products, Inc. FPPPTh. ThreadFil5 are registered trademarks of Fire Protection Products, Inc. MADU IN U.S.A. Features Heavy Duty Cuffing Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke FIRICV:q; SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSI-IEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.