HomeMy WebLinkAbout2525 EL CAMINO REAL; 132; FPC2017-0150; PermitPERMIT REPORT Ccity of Carlsbad Print Date: 02/03/2022 Job Address: 2525 EL CAMINO REAL, # 132, Permit Type: FIRE-Construction Commercial Parcel #: 1563022700 Valuation: $66,974.40 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: WATCH EDGE -FIRE ALARM TI CARLSBAD, CA 92008-1207 Work Class: Fire Alarm Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2017-0150 Status: Closed - Finaled Applied: 06/01/2017 Issued: 06/21/2017 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: Applicant: JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS 3568 RUFFIN RD SAN DIEGO, CA 92123-2597 (858) 633-9123 FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP P0 BOX 3042 BOCA RATON, FL 33431-0942 (561) 341-7780 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue; Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov lmplexbrinnelI Lt- 3568 Ruffin Road ij qc. :::o::::otm0 92123 -633-91-01 Sirnp/exGrinnell www.simplexgrinnell.com S Fire Detection and Alarm System Product Submittal Project: Watch Edge The Shoppes at Carlsbad 2525 El Camino Real Carlsbad, CA FPC20I 7-0150 2525 EL CAMINO REAL UN11132 For any questions regarding this submittal, please contact Douglas Daniels, 858- 5 633-9123 or ddaniels(simplexqrinneIl.com 5/30/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco. TM S. tqcU Simp/exGrinnell impiexnnneii Lt- 3568 Ruffin Road San Diego, California 92123 P: 858-633-9100 F: 858-633-9101 www simplex grinnell. corn Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. E 4100-9311 FACP (existing) 7165-0026:0251 1 4090-9010 Relay lAM 7300-0026:0223 2 4906-9204 Strobe 7125-0026:0235 2 49SV-APPLC Speaker Strobe 7320-0026:0384 Business Information Warranty Information S 5/30/2017 REV.#: 0 PROJECT Safer. Smarter. Tyco .TM 4I00ES Fire Control Panels Addressable Fire Detection and Control Basic Panel Modules and Accessories 4100ES Cabinets are Available with One, Two or Three Bays Option Modules (Continued) Additional IDNet 2 communications SLCs, IDNet 2+2 Modules with quad short circuit isolating output loops; additional power supplies, alarm relays, and auxiliary relays LED/switch modules and panel mount printers; VESDA Air Aspiration Systems interface, ASHRAE BACnet Interface, TCP/IP Bridges Battery brackets for seismic area protection (see page 2) 4100ES compatible legacy interface modules, including control of conventional (non-addressable) NACS (see data sheet reference list on page 12) 4I00ES Listings reference: UL 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UUKL) UL 2017, Process Management Equipment (QVA)() UL 1076, Proprietary Alarm Units-Burglar (APOU) UL 1730, Smoke Detector Monitor (UULH) UL 2572, Mass Notification Systems (PGWTvl); refer to data sheet S4100-0034 for audio equipment ULC S527, Control Units for Fire Alarm Systems IM CPU provides dual configuration programs: Two programs allow for optimal system protection and commissioning efficiency with one active program and one reserve; downtime is reduced because the system stays running during download PC based programmer features: Convenient front panel accessed Ethernet port for quick and easy download of site-specific programming Modifications can be uploaded as well as downloaded for greater service flexibility; AND, firmware enhancements are made via software downloads to the on-board flash memory * See pages 6 and 7 for product that is UL or ULC listed and additional listing information. This product has been listed by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions concerning material presented in this document NYC Fire Dept COA #6151. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. S4100-0100-13 1/2016 LiSimplEx S UL, ULC, CSFM Listed, FM, NYC Fire Dept Approved* I i(! I (-1 Master Controller (top) bay standard equipment: 32-Bit Master Controller with color-coded operator interface and raised switches for high confidence feedback Dual configuration program CPU, convenient service port access, and capacity for up to 2500 addressable points CPU assembly includes 2 GB dedicated compact flash memory for on-site system programming and information storage An Enhanced Power Supply (EPS) and battery charger (9 A output) with on-board: IDNAC SLCs (signaling line circuit) for addressable appliance control, an IDNet 2 Module for addressable device control; and programmable function auxiliary output Also available with InfoAlarm Command Center expanded content user interface (see data sheet S4100-0045) Standard addressable device interfaces include: 250 point addressable device IDNet 2 SLC that supports TrueAlarm analog sensors and IDNet communications monitoring and control devices with an electrically isolated output channel allowing use with either shielded or unshielded, twisted or untwisted single pair wiring; and providing dual short circuit isolating output loops MINIPLEX Transponder and remote LCD and LED annunciator support via RUI+ (remote unit interface) communications port with electrically isolated output for use with either shielded or unshielded, twisted or untwisted single pair wiring (refer to details on page 6) Standard power supplies (EPS) provide enhanced power delivery IDNAC SLCs to addressable notification appliances: With IDNAC SLCs, a constant 29 VDC source voltage is maintained during alarm, even during battery operation, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby Efficiencies include lower strobe currents, wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, and the ability to use smaller gauge wiring - all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will also operate during worst case alarm conditions IDNAC SLCs are compatible with both TrueAlert ES and lrueAlert addressable notification appliances, and remote 4009 IDNAC Repeaters to extend power and wiring distance even farther Optional modules and connections include: Fire Alarm Network Interfaces, city connections, and up to five (5) RS-232 ports for printers and terminals Building Network Interface Module (BNEC) for Ethernet connectivity options (see data sheet S4100-0061) Side mounted DACT assembly requiring minimal panel space; DACT is compatible with IP Communicators Emergency communications systems (ECS) equipment; 8 channel digital audio or 2 channel analog audio C 4I00ES Series Fire Detection and Control Panels provide extensive installation, operator, and service features with point and module capacities suitable for a wide range of system applications. An on-board Ethernet port provides fast external system communications to expedite installation and service activity. Dedicated compact flash memory archiving provides secure on-site system information storage of electronic job configuration files to meet NFPA 72 (National Fire Alarm and Signaling Code) requirements. Modular design. A wide variety of functional modules are available to meet specific system requirements. Selections allow panels to be configured for either Stand-Alone or Networked fire control operation. Module Bay Description. The Master Controller Bay (top) includes a standard multi-featured enhanced power supply (EPS) with IDNet 2 Module, the master controller board, two vertical expansion blocks, and operator interface equipment. The Expansion Bays include a Power Distribution Interface (PDI) for connection of single or multiple block modules, and/or slot style (motherboard/daughter card) modules. The Battery Compartment (bottom) accepts two batteries, up to 50 Ah, to be mounted within the cabinet without interfering with module space. 4100-6080 DACT Master Controller Bay mounting location jboar d t .1 w ' 'ble er with rboard [Expansion Bayl JU Typical bays with mixed module sizes [Expansion Bay 2}jf [Battery Compartment ... 4100ES Module Placement Reference in 3-Bay Cabinet Iiirn rirn I Boxes can be close-nippled; each box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Cabinet assembly design has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires 4100-7912 option for additional legacy card stabilizer brackets and battery brackets as detailed on data sheet S2081-0019 The latching front panel assembly easily lifts off for internal access Modules are power-limited (except as noted, such as relay modules) The NEMA 1/1P30 box is ordered separately and available for early installation Doors are available with tempered glass inserts or solid; boxes and doors are available in platinum or red Boxes and door/retainer assemblies are ordered separately per system requirements; refer to data sheet S4100-0037 Lf. .1-] jc r-TIMMIFTRIM-RUTI-TT-1 "- The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly viewable and accessible (no access door) 12:Vx 25 -14 19 NNUIAL I I I Upload/Download Basic operator instructions Panel sounder Ethernet port access are printed on the interface (under sliding cover) mounting plate liii ii!1 IY "Install Mode" allows grouping of multiple troubles for uninstalled modules and devices into a single trouble condition (typical with future phased expansion); with future equipment and devices grouped into a single trouble, operators can more clearly identify events from the commissioned and occupied areas Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring "Recurring Trouble Filtering" allows the panel to recognize, process, and log recurring intermittent troubles (such as external wiring ground faults), but only sends a single outbound system trouble to avoid nuisance communications WALKTEST silent or audible system test performs an automatic self-resetting test cycle Support for TrueAlarm individual analog sensing and IDNAC addressable notification with front panel information and selection access Optional 4190-6104 Truelnsi9ht Module mounting location EPS Power Supply with lDNeI 2 Module S 34100-0100-13 1/2016 Ground Fault Manual Evac [City isconnect 0= EltrPII: Or =1 Almost Dirty FuiIt L Latch L!A1N1lT flh1(JIt4- Convenient and extensive operator information is provided using a logical, menu-driven display Multiple automatic and manual diagnostics for maintenance reduction Alarm and Trouble History Logs (up to 1250 entries for each, 2500 total events) are available for viewing from the LCD, or capable of being printed to a connected printer, or downloaded to a service computer Convenient PC programmer label editing Password access control Convenient Status Information. With the locking door S closed, the glass window allows viewing of the display, status LEDs, and available operator switches. Features include a two-line by 40-character, wide viewing angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. LED indicators describe the general category of activity being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to the control switches and allows further inquiry by scrolling the display for additional detail. SIX SYSTEM STATUS INDICATOR LEDs provide system status indications in.addition to LCD information, LEDs flash to indicate the condition and then when acknowledged, ULC SYSTEMS require designating remain on until reset: a Ground Fault Fire Alarm & Priority 2 Alarm, red LED indicator Supervisory & Trouble, yellow LED Alarm Silenced, yellow LED / / AC Power, green LED (on for normal) FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts PRIORITY 2 ACK acknowledges a Priority 2 Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SUPV ACK acknowledges system supervisory conditions, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts TROUBLE ACK acknowledges system troubles, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts THREE PROGRAMMABLE LEDs provide custom labeling, the top S two LEDs are selectable as red or yellow, the bottom LED is selectable as green or yellow Custom label insert L Waterfiow-East i ,flO 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions, provides up to 40 characters for custom label information FIRST ALARM DISPLAY: Operation can be selected for maintained display of first alarm until acknowledged ALARM SILENCE causes audible and visible notification appliances to be silenced (default operation, may be modified through panel programming for compliance with local requirements) SYSTEM RESET restores control panel to normal when all alarmed inputs are returned to normal SYSTEM IS NORMAL 15 am THU 24-OCT-15 S FIVE PROGRAMMABLE 1 1 POINT STATUS I ADDITIONAL FUNCTION 1 1 LCD NAVIGATION 1 1 NUMERIC KEYPAD for FUNCTION SWITCHES, I I CONTROL KEYS: I KEYS: I CONTROL: I [Point category and point each with a yellow LED Point Enable and Event Time Request Menu selection selection (alphabet indicator Disable [re Information Requestj Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position this time) J I I [ j Force Off or Disarm selection buttons Return On/Off or I Arm/Disarm to Auto Mode 3 S4100-0100-13 1/2016 IDNet Addressable Device and IDNAC Addressable Notification Appliance Control Overview. The 4100ES BPS power supply with IDNet 2 Module provides addressable initiating device and IDNAC addressable notification appliance Signaling Line Circuits (SLCs) that supervise wiring connections and the individual device/appliance communications status on their SLC. With these 2-wire SLCs, initiation, monitoring, and control devices such as manual fire alarm stations, TrueAlarm sensors, control relays, and sprinkler waterfiow switches; and notification appliances such as strobes and horns can communicate their identity and status and receive fire alarm system control. Additional interface modules include circuit isolators, conventional DC zone adapters, and interface to other system circuits such as fans, dampers, and elevator controls. 119011FIrererITT-n. Me Each addressable device on an IDNet communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Both Class B and Class A operation is available. Sophisticated p011 and response communication techniques ensure supervision integrity and allow for '1-tapping" of the circuits for Class B operation. Devices with LEDs pulse the LED to indicate receipt of a communications poll and can be turned on steady from the panel. With addressable devices, the location and status of the connected device is monitored and logged, and displayed on the operator interface LCD and on remote system annunciators with each device having its own 40 character custom label for precise identification. kflTT.t1 i nw_T r i tII:1 I.1LSJ.I] ti1 Addressable initiating device communications include operation of lrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. TrueAlarm Addressable Sensor Reference ............. TrueAlarm Photo TrueAlarm Photo/Heat Sensor with Base I Sensor in CO Base Programmable sensitivity of each sensor can be selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. To evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read (or downloaded as a report) and compared to the alarm threshold directly in percent. CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. (refer to data sheet S4098-0052 for details) TrueAlarm heat sensors can be selected for fixed temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to I{VAC system problems. Readings can selected as either Fahrenheit or Celsius. TrueSense Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 4100E5 IDNet address. The panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this operation, refer to data sheet S4098-0024. W.LJI il.I-11 [4-Li ii. II fl TI1II I[4!j 1444 Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72 requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. CO Sensors track their 10 year active life status providing indicators to assist with service planning. Indicators occur at: 1 year, 6 months, and end of life. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. il.irvx r i -i*isirm.i'i r'A'1nIT1 1] L.(1 IDNet Addressable Channel Capacity. The CPU bay standard power supply (EPS) provides an IDNet 2 Module providing a signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. IDNet 2 and IDNet 2+2 Module SLCs are isolated from other system reference voltages to reduce common mode noise interaction with adjacent system wiring. Additional 250 address IDNet 2 or IDNet 2+2 Modules are available. IDNet 2 and IDNet 2+2 SLC Wiring Specifications Maximum Distance ito 125 4000 ft (1219 m); 50 ohms from Control Panel 2500 feet (762 m); 35 ohms per Device Load 126-250 Total Wire Length Allowed With Up to 12,500 ft (3.8 km); T' Taps for Class B Wiring 0.60 pF Maximum Capacitance Between 1 hF IDNet 2 Channels Loading per device 0.8 mA supv., 1 mA alarm; 2 mA per activated device LED Wire Type and Connections Shielded or unshielded, twisted or untwisted wire* Connections Terminals for 18 to 12 AWG (0.82 mm to 3.31 mm2) IDNet 2 and IDNet 2+2 Module Compatibility: IDNet communicating devices and TrueAlarm sensors including QuickConnect and QuickConnect2 sensors * Some applications may require shielded wiring. Review your system with your local Simplex product supplier. S S4100-0100-13 1/2016 [NAC SLC Control bf TrueAlert and TrueAlert ES Addressable Notification Addressable notification appliance communications S include operation of TrueAlert and TrueAlert ES Visible only (VIO, strobe), Audible only (AIO, horn), Audible/Visible (A/V, horn/strobe), and strobes of Speaker/Visible (S/V) notification appliances. (S/V appliances require separate speaker wiring.) IDNAC SLC addressable communications allow each horn and strobe to be individually controlled using a single two-wire circuit, confirms the wiring connections to the individual notification appliance's electronic circuit, and confirms communications between each appliance and the fire alarm control panel. Addressable communications increases supervision integrity versus conventional notification systems by providing supervision beyond the circuit wiring to each individual appliance and by constantly verifying the ability of each appliance to communicate with the control panel. Individual Appliance Status and Settings. The fire alarm control panel monitors and records each addressable notification appliance status, type of appliance, and its configured appliance settings. A fault in any individual appliance automatically reports a trouble condition to the control panel. S S TrueAlert ES Addressable Appliance Reference t!F: i T!1 NO (horn) V/O (strobe) AN (horn/strobe) Virtual NACs Provide Control Convenience. For control convenience, IDNAC notification appliances can be grouped into Virtual NACS (VNACs) for group control, grouping that can be made across SLCs, not defined by their wiring connection. Panel Control Convenience. Applicable operation settings for each appliance can be programmed without having to replace appliances or remove them from the wall or ceiling. An appliance's VNAC notification zone can be easily changed through programming without having to add additional circuits, conduit, and wiring. Audible and visible appliances for non-Fire Emergency Communications notification can be programmed to operate separately on the same pair of wires as the fire alarm notification appliances. The result is lower installation, retrofit, and overall life-cycle cost of ownership compared with traditional conventional notification systems. Installation, Retrofit, and Life-Cycle Cost Benefits. With each addressable appliance capable of being controlled separately on the same two-wire IDNAC SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be "T-tapped" allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Location Information, Diagnostics and Troubleshooting. Each addressable notification appliance has its own 40 character custom label to identify the location of the appliance and to aid in troubleshooting fault conditions. In conventional notification systems, conventional appliances are not capable of communicating with the control panel. Fault reporting on a conventional system is limited to the circuit wiring and the entire area (zone) covered by appliances on the notification appliance circuit (NAC) making it much more difficult and costly to locate and correct the source of a problem. Using the TrueAlert magnet test allows each appliance to individually identify its candela setting and address and to briefly operate if desired, and using the TrueAlert ES Appliance Self-Testfeature provides detailed performance verification per appliance. On-Board Test Sensors. TrueAlert ES appliances are equipped with on-board sensors to detect strobe and/or horn output allowing efficient and unobtrusive Self-Testing. When Automatic Self-Test is initiated from the control panel, each appliance within the selected VNAC group will briefly operate and then report its Self-Test status to the control panel, all within several seconds. Silent Self-Test can be selected to test only visible appliance if desired. The control panel is in a trouble condition during testing and in the event of an alarm, Self-Test is automatically terminated. Additionally, Automatic Self-Test can be scheduled to occur at a convenient time on a regular basis. (Requires version 2.03.01 or higher software.) Automatic Self-Test results are communicated to the control panel with a time and date stamp and are stored in memory. Results are viewable at the front panel display and printed reports can be generated from the panel service port. (See sample reports on page 11.) Individual Self-Test is selected from the control panel when individual appliances need to be observed to operate. Each appliance in the selected VNAC group will turn on its LED until individually activated by applying a magnet. After performing the individual test, the appliance LED turns off to indicate completion. Results are recorded the same as during the automatic test. liii _tI*1 III F1T LJ1i 11 {1(1(] it.( EPS Power Supplies provide three, 3 A IDNAC SLCs for control and power to TrueAlert ES and TrueAlert addressable notification appliances. Both power supplies incorporate an efficient switching design that provides a regulated output of 29 VDC, even during battery operation. With 29 VDC minimum output at the panel, addressable notification SLCs can support wiring distances 2 to 3 times farther than available with conventional notification, or support more appliances per SLC, or work with smaller gauge wiring, or combinations of these benefits, all resulting in installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. 11011,739111711=, lti it.iTA lIii Et4 IDNAC SLC Capacity: Up to 127 addresses and up to 139 unit loads (appliances are typically one unit load, devices such as Isolators may require more than one load, refer to individual device data sheet for specific information) Recommended wire type UTP, unshielded twisted pair Maximum wire length allowed with "T-Taps" for 10,000 ft (3048 m) Class wiring, _B_ _per _SLC Maximum wire length per 4000 ft (1219 m) SLC to any appliance Appliance Supervisory 1 unit load = 0.8 mA per appliance Current Wiring connections Terminals for 18 to 12 AWG (0.82 mm to 3.31 mm2) Installation Instructions (see 579-1015 for more information) I S4100-0100-13 1/2016 tuI:1'rnFi,1W1 Mounts in Slot 2 of a two slot motherboard and provides EPS with IDNet 2 Module Details (Continued): one Class B or Class A, RUI+ isolated communications • DCAI (Dual Class A IDNAC Isolator) Module creates channel with earth fault detection RUI+ isolated communications controls up to 31 remote devices per master controller at up to 2500 ft (762 m) for single run, or 10,000 ft (3048 m) total if wiring is Class B and T-tapped; if more distance is required, up to four total RUT channels are supported; add up to three 4100-1291 RUT Expansion Modules (4100-1291 provides unisolated RUT communications) Compatible RUI+ remote equipment includes: MENIPLEX transponders, 4603-9101 LCD Annunciators, and 4100 Series 24 I/O and LED/Switch modules RUI Expansion Module 4100-1291 is also compatible with the RUI+ remote equipment listed above; and is required for control of 4602 Series LED/Switch and I/O Annunciator modules, including 4602-9101 Status Command Units (SCU), and 4602-9102 Remote Command Units (RCU); (refer to data sheet S4602-0001) Open slot space on the left of the CPU motherboard is available for either another dual slot motherboard, or for one or two block modules (refer to diagram on page 2) Slot 1 of the motherboard is primarily for the 4100-6078 Network Interface Board with media modules EPS (Enhanced Power Supply) with IDNet 2 Module Details: (see page 9 for specifications) Rating is 9 A output with "Special Application" appliances Outputs are power-limited, except for the battery charger Provides system power, battery charging, auxiliary power, earth detection, on-board electrically isolated IDNet 2 Module with 250 point SLC, three on-board 3 A IDNAC SLCs, and provisions for either an optional City Connect Module or an optional AlarmlSupv/Thl Relay Module IDNet 2 Module SLC Output provides Class B or Class A communications for up to 250 addressable devices with dual short circuit isolating loop outputs (see details on page 4) Note: The "IDNet 2 Module" replaced the "IDNet 1+ Module" and the term "EPS with IDNet 2 Module" replaces the term "EPS+" two Class A outputs from one IDNAC SLC Class B Input; up to two can be connected to one IDNAC SLC, with up to 6 total per EPS; total Class A output loop current is limited to the 3 A rating of the IDNAC SLC Battery Charger is dual rate, temperature compensated, and charges up to 50 Ali sealed lead-acid batteries mounted in the battery compartment (33 Ali for single bay cabinets); also is UL listed for charging up to 115 Ali batteries mounted in an external cabinet (see data sheet S2081-0012 for details) Battery and Charger Monitoring includes battery charger status and low or depleted battery conditions; status information provided to the master controller includes analog values for: battery voltage, charger voltage and current, actual system voltage and current, and individual IDNAC SLC currents Low Battery Cutout is selectable for each EPS power supply, Canadian models are shipped selected, other models are shipped unselected 2 A Programmable Output: Select for conventional non-synchronous NAC operation to provide supervised reverse polarity for sounder base power, Suppression Release Peripheral (SRP) power, or other coded NAC operation requirements Select for Auxiliary (AUIX) operation for sounder base power, 4-wire detector power, or door holder; supervised AUX operation does not require an end-of- line relay to provide Power-Limited operation EPS Mounted Optional Modules (select one): City Connect Module (4100-603 1, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC S Ii'F liii I fll-fl Ft1 ME= Master Controller and Expansion Bay Selection Model Model Type and Listing Description Current 4100-9311 120 VAC, 50/60 Hz Input UL 4100ES Master Controller Assembly with LCD display, operator interface and RUI+ isolated output communications interface; 9 A EPS (Enhanced 4100-9312 English French 1120 VAC, 50/60 Hz Canadian - ULC 4100-9313 - Power Supply) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B Without IDNet devices: IDNAC SLCs, one 2 A output configurable for Supervisory = 425 mA 4100-9511 220-240 VAC, 50/60 Hz Input UL Auxiliary Power or Simple NAC operation and Alarm = 735 mA expansion slot for City Circuit orAlarrn/Supvrrbl Relay option Note: Master Controller current does not subtract - from 9 A output rating 4100-9331 120 VAC, 50/60 Hz input UL 4100ES Master Controller Assembly ; same as above models except without LCD Display and Operator Interface 4100-9332 120 VAC, 50/60 Hz input, - ULC Canadian, English 4100-2300 Expansion Bay Assembly; order for each required expansion bay 4100-2303 Slot Module Stabilizer Bracket, used when expansion bays have style modules (Continued on next page) 6 S41000100-13 1/2016 S S S C Module Selection Information Communication Modules Model 4100-6078 Description For Master Controller; mounts in Slot 3 Modular Network Interface; each requires For Redundant Master Controller two media modules (below) Size 1 Slot Supv. 46 mA Alarm 46 mA 4100-6061 1 Slot 46 mA 46 mA 4100-6056 Wired Media Module Select two media cards as required; mounts on Fiber Optic Media Module 4100-6078 or 4100-6061; Class B or Class X operation N.A. 55 mA 55 mA 4100-6057 N.A. 25 mA 25 mA 4100-6047 Building Network Interface Card (BNIC), refer to data sheet S4100-0061 for details 2 Blocks 291 mA 291 mA 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6078 or 4100-6061 Network Interface Card, requires telephone line connection N.A. 60 mA 60 mA 4100-1291 Remote Unit Interface Module (RUI, unisolated); up to 3 maximum per control panel 1 Slot 85 mA 85 mA 4100-6031 Select one per EPS (Note: maximum one City Circuit module per panel) City Circuit, with disconnect switches N.A. 20 mA 36 mA 4100-6032 City Circuit, w/o disconnect switches N.A. 20 mA 36 mA 4100-6033 Alarm/SupvlTbl Relay, 3 Form C relays, 2 A @ 32 VDC N.A. 15 mA 37 mA 4100-6046 Dual Port RS-232 standard interface (single block) 3 maximum RS-232 Modules per panel 1 Block 60 mA 60 mA 4100-6038 Dual Port RS-232 with 2120 interface (slot module) 1 Slot 132 mA 132 mA 4100-6079 SafeLINC Internet Interface (refer to data sheet S4100-0062 for details) 2 Blocks 145 mA 145 mA 4190-6104 Truelnsight Remote Monitoring Module (refer to data sheet S4100-0063 for details) Side Mt. 62 mA 73 mA 4100-6101 Physical Bridge, Class B, includes 1 modem module and 2 wired modules 1 Slot 210 mA 210 mA 4100-6102 Physical Bridge, Class X, includes 2 modem and 2 wired modules 2 Slots 300 mA 300 mA 4100-6048 VESDA Aspiration System Interface (refer to data sheet S4100-0026 for details) 1 Slot 132 mA 132 mA 4100-6080 DACT, Point or Event Reporting; 1 shipped unless 4100-7908 is selected; 2 max. per system; includes 2, 2080-9047 cables, 14 It (4.3 m) long, RJ45 plug and spade lugs Side Mt 30 mA 40 mA Additional Enhanced Power Supplies, Expansion Power Supply, and Accessories (for additional non-addressable Power Supplies, refer to data sheet S4100-0031) Model Voltage/Listing Description Size Supv. I Alarm LIL & Expansion EPS with IDNet 2 Module; 9 A Expansion Power 4100-5311 120 VAC ULC Supply (EPS) with battery charger, electrically isolated 250 point IDNet 2 Module, three Class B IDNAC SLCs, one 2 A output 4 Blocks Right 225 mA 490 mA ___________ ____________ - configurable for Auxiliary Power or Simple NAC operation, and Side add IDNet device 4100-5313 220-240 VAC UL expansion slot for City Circuit or Alarm/SupvlTbl Relay option; 120 currents separately VAC model has selectable low battery cutout 4100-5325 120 VAC UL & Enhanced Power Supply (EPS); 9 A EPS, functionally identical to the Expansion EPS except without the IDNet 2 Module 4 Blocks ULC Right Side 125 mA 220 mA 4100-5327 220-240 VAC UL 4100-5101 120 VAC UL Expansion Power Supply (XPS); 9Aoutput, 3 built-in Class NB conventional (non-addressable) 3 A NACs that can 120 VAC , 4100-5103 Canadian ULC also be selected as 2 A auxiliary power output, 2 A separate 2 Blocks 50 mA 50 mA auxiliary power output; without battery charger; Canadian 4100-5102 220-240 VAC UL model has low battery cutout 4100-5115 NAC Expansion Module, 3 NACs, Class A/B, mounts on XPS only N.A. 25 mA 25 mA Dual Class A IDNAC Isolator (DCAI), converts a single Class B IDNAC SLC input to two Class A or two Class B SLC outputs; provides short circuit isolation between 4100-6103 each Class A or B output circuit; connect up to two DCAI Modules per IDNAC SLC 1 Block 8.3 mA 18.5 mA input up to a maximum of 6 DCAI Modules per EPS; each isolated output SLC used requires one IDNAC address the total current remains controlled by the Class B input source SLC at 3 A maximum 4100-5152 12 VDC Power Option, 2 A maximum 1 Block 1.5 A maximum 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum 1 Block included w/loads 4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet 4100-0638 4100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from EPS System Option for Seismic Compliance Model I Description 4100-7912 System option for Seismic compliance, provides additional stabilizer brackets required for legacy style cards Module Selection is continued on next page S4100-0100-13 1/2016 [Module Selection Information (Continued) Addressable Interface Modules (Note: Total of initiating SLCs per CPU, including VESDA Interface, is 30) Model IDescription I Supv. I Alarm 41003109* IDNet 2 Module, 250 point capacity; no devices electrically isolated output with two short ___________ circuit isolating Class B or Class A output loops, 1 block; standard on EPS with 50 devices IDNet 2 Module; alarm currents for 50 and above devices includes 20 device 125 devices LEDs in alarm 250 devices 50 mA 60 mA 90 mA 150 mA 150 mA 225 mA 250 mA 350 mA 41003110* IDNet 2+2 Module, 250 point capacity; electrically isolated output with four short no devices circuit isolating Class B or Class A output loops, 1 block; mounts in expansion 50 devices bay or available master controller bay module locations only, not applicable for 125 devices EPS mounting; alarm currents for 50 and above devices includes 20 device LEDs in alarm 250 devices 50 mA 60 mA 90 mA 150 mA 150 mA 225 mA 250 mA 350 mA IDNet Short Circuit Isolating Loop Output Module; mount up to two on a 4100-3109 module; for use with 41003111* 4100-3109 modules in expansion bays or available master controller bay module locations only; not applicable for mounting on a 4100-3109 mounted on an EPS; this option is for aftermarket field installation only Four Loop IDNet Master Controller; for the Master Controller Assemblies listed on page 6, this option moves the 4100-3112 standard IDNet 2 Module from the Master Controller EPS to an available block space in the master controller bay and adds 2, 4100-3111 IDNet Loop Output Modules; requires selection of Factory Built Option 4100-7905; current requirements remain the same *Note: Loading per IDNet device (no LEDs on) = 0.3 mA supervisory and 1 mA alarm. Each IDNet 2 and IDNet 2+2 Short Circuit Isolating Loop Output can be individually controlled for system diagnostics and can be assigned a public point for Fire Alarm Network annunciation. Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on page 10) Model 4100-3202 Description 4 DPDTw/feedback Resistive Ratings IOA@ 250 VAC Inductive Ratings 10A@ 250 VAC Size 2 Slots Supv. 15 mA Alarm 175 mA 4100-3204 4 DPDT w/feedback 2 A @ 30 VDCNAC 1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 60 mA 4100-3206 8 SPDT 3 A @ 30 VDC/120 VAC 1-1/2 A @ 30 VDC/120 VAC 1 Block 15 mA 190 mA Current Calculation Notes: To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered by panel power supplies. 0 To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel SLC and NAC loads and all external loads powered from panel power supplies. End User Programming Software (requires 4100-8802) Model I Description 4100-8802 I Programming Software (select) End User Programming Software Selection (select maximum of one each from below) Model j Description 4100-0292 1 Custom Labels Editing; allows editing of 40 Character Custom Labels for non-system user points Access Level/Passcode Editing; allows user to re-assign Access Levels and Passcodes for each display function; 4100-0296 Acknowledge, Alarm Silence, System Reset, Point Enable/Disable, WALKTEST Enable/Disable, Clear History Logs, Change Time & Date, etc. 4100-0295 1 Port Vectoring Setup and Control; Allows vectoring of events to PC Annunciator, Printers, LCD Annunciators, etc. WALKTEST Configuration Setup and Control; Allows user to create or edit WALKTEST groups used to test system 4100-0298 initiating devices and signals by a single person, these groups allow an inspector to conduct a one-person WALKTEST in a specific area of a building (or different buildings), and limit the activation of the building signals to only the intended area; up to 8 WALKTEST groups are supported Miscellaneous Accessories Model 4100-1279 Description Single blank 2" display cover; 4100-2302 provides a single plate for a full bay 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-9856 4100ES Canadian French Appliqué Kit; Simplex, 4100ES, ContrOle Incendie 4100-9868 Special Purpose Appliqué Kit: Simplex, Elevator Recall Control and Supervisory Control Unit, 4100ES 4100-9869 Special Purpose Appliqué Kit: Simplex, Sprinkler Waterflow and Supervisory Station, 4100ES 4100-6029 Smoke Management Application Guide; required for UUKL listing 41O0034 Tamper Switch, one per cabinet assembly if required; monitors solid door for panels with solid door; monitors the internal retainer panel for panels with class door (not the glass door); has a built-in addressable IDNet lAM 2081-9031 Series resistor for WSO, lDCs (NO. water flow and tamper on same circuit, wires after water flow and before tamper) 4700, 1 W, encapsulated, two 18 AWG leads (0.82 mm2 ), 2-1/2" Lx 1-3/8" Wx 1" H (64mm x 35mm x 25mm) S4100-0100-13 1/2016 S S S General Specifications 120 VAC Models 4.6 A maximum @ 102 to 132 VAC, 50/60 Hz 220-240 VAC Models 2.3 A maximum @ 204 to 264 VAC, 50/60 Hz; Enhanced Power Supplies (EPS) separate taps for 220/230/240 VAC Battery Input Rating 12 A maximum @ 24 VDC (during battery operation) Input Power 120 VAC Models 4 A maximum @ 102 to 132 VAC, 60 Hz Expansion Power Supplies (XPS) 220-240 VAC Models 2 A maximum @ 204 to 264 VAC, 50/60 Hz; separate taps for 220/230/240 VAC 9 A output for "Special Application" appliances Total Power Supply Note: The 9 A output rating of the EPS was determined Output Rating such that optional module currents, and external device and appliance currents can be directly added together, not to exceed 9 A total. Output switches to 3 A, regulated 29 VDC during Alarm, 127 addresses, 139 Power Supply Output IDNAC SLC Ratings unit loads; DC-DC converter circuit is >92% efficient over battery backup during mains AC Ratings for EPS operating range failure or brownout Output terminals are rated for 18 to 12 AWG with duplicate conditions output terminals rated for two wires each, allowing up to IDNAC SLC Wiring four (4) Class B branch circuit T-taps to be made in the cabinet; additional T-taps may be made in external wiring junction cabinets or boxes 2 A maximum, 24 VDC nominal (19.5 to 31.1 VDC) Auxiliary Power Tap Compatible Special Application Appliances Simplex TrueAlert ES and TrueAlert addressable notification appliances; contact your Simplex product representative for compatible appliances Battery Charger Battery capacity range UL listed for battery charging of 6.2 Ah up to 115 Ah (batteries larger than 50 Ah Ratings for EPS require a remote battery cabinet); ULC listed for charging up to 50 Ah batteries (sealed lead-acid Charger characteristics Temperature compensated, dual rate, recharges depleted batteries within 48 batteries) and performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Including module currents and auxiliary power outputs; Total Power Supply NAC outputs are rated 9 A output for "Special Application" Power Supply Output Ratin g "Regulated non-addressable appliances; 4 A output for 24 Output switches to Output Ratings for DC" power (see details below); 6 A output with each NAC battery backup XPS (nominal 28 VDC selected as auxiliary power output during mains AC on AC; 24 VDC on Auxiliary Power Tap failure or brownout 2 A maximum I battery backup) conditions 2 A maximum per NAC; NACs Programmed for Rated 19.1 to 31.1 VDC Auxiliary Power 5 A maximum total Special Application I Simplex homs, strobes, and combination horn/strobes and speaker/strobes (contact your Simplex product Appliances I representative for compatible appliances) Regulated 24 DC Appliances Power for other UL listed appliances; use associated external synchronization modules where required Operating Temperature 32° to 120°F (0° to 49° C) Environmental Operating Humidity Up to 93% RH, non-condensing @ 90° F (32° C) maximum Additional Technical Reference Description Document Description Document ES Installation Instructions 574-848 IDNet 2 and 2+2 Module Installation Instructions 579-1169 ES Operating Instructions 579-197 EPS Installation Instructions 579-1015 DCAI Module Installation Instructions 579-1029 S4100-0100-13 1/2016 S Expansion Bay Module Loading Reference Slot Slot Slot Slot slot slot Slot slot Block A Block C Block E Block G Block B Block 0 Block F Block H Expansion Bay Chassis Size Definitions: 1 Block = 4" W 5.65" H (1 02 mm x 144 mm); (often called 4 x 5 modules) I Slot =2"Wx 11.3" H(51 mm x 287 mm), typically a motherboard with daughter card Mounting and CPU Bay Module Reference (* indicates supplied modules) lOne 2" card: either 4100-6078 Network Module with [rnedia cards or 4100-6038 RS-232/2120 Interface - [Master Controller Bay 4100-6030 Service Modem mounts Space for two 2" slot I only on master controller board :l::rr n::in;et Knockout Cabinet height: or 4100-6032 4100-6031 screw/nail (2 bay shown block modules, or one City Circuit or 4100-6033 holes (for for reference) double block (vertical Relay Module mounts on mount) module semi-flush bottom of EPS mounting) I Bay = 22" 1'l 2Bay40" Optional 4100-6049 (1016 mm) Truelnsight Module 4100-6080 DACT i-\ , j - - mounting location mounting location •EPS power supply Exposed cabinet for 0 3 Bay - 56 with IDNet 2moduJ semi-flush mounting - (1422 mm) qontroleT_ 1/2" (12.7 mm) Wallboardwith erboardJ minimum reference forTypical Expansion Bay , L I semi-flush showing mixed module slzes)j I ri I 1 mounting, I I stud IH Two bay cabinet shown Stud without dress panel j I alignment - I markers, each side Door 4-3/4" fl fuJ (121 mm) H I 4" stud Battery Compartment (50 Ah maximum) J I Door can be hung L- I [hinged leftor right f 1 .111 ' 24" (610 mm) .0-146-29/32" / (175 mm) [Optional semi-flush trim kit] 4 11-11/16" 10 (296 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. 10 S4100-0100-13 1/2016 S H rueAlert ES Appliance Self-Test iLast Test Results Report Example Service Port Page 1 REPORT 10 TrueAiertES Self-Test Report 12:34:56pm WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-1-1 VO FIRST FLOOR (up to 40 characters) 03-DEC-14 NO OUT N/A Ti-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL Ti-2-4 AO FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP TRUEALERTES SELF-TEST REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort Results Description: NORMAL = works correctly NO OUT = No Output, no light or sound was detected NOT TST = no result; either the appliance did not return a result before the test ended or the test was conducted as silent (strobes only) and audible appliance was not activated N/A = not applicable (no strobe on audible only, etc.) UNSUPP = appliance not compatible with Self-Test (TrueAlert addressable appliance not TrueAlert ES addressable appliance) Note: Additional TrueAlert ES Self-Test information is detailed in ES Operating Instructions 579-197 shipped with the panel. TrueAlert ES Appliance Self-Test All Test Results Report Example Service Port REPORT 10 TrueAiertES Self-Test Report 12:34:56pm Page 1 WED 03-DEC-14 Point ID Custom Label Date Visual Audible Ti-i-1 VO FIRST FLOOR 03-DEC-14 NO OUT N/A Ti-2-5 AV FIRST FLOOR EAST WING 03-DEC-14 NO OUT NORMAL Ti-2-6 AV FIRST FLOOR NORTH ENTRANCE 30-OCT-14 NO OUT NORMAL T7-3-55 AO SECOND FLOOR EAST WING 03-DEC-14 N/A NO OUT T8-2-45 AV SECOND FLOOR ROOM 29 03-DEC-14 NOT TST N/A Ti-i-il AV FIRST FLOOR SOUTH ENTRANCE 30-OCT-14 NORMAL NORMAL T8-2-60 AV SECOND FLOOR ROOM 22 03-DEC-14 NORMAL NORMAL T1-2-4 AO FIRST FLOOR ROOM 17 03-DEC-14 N/A UNSUPP T1-2-7 AO FIRST FLOOR ROOM 12 30-OCT-14 N/A UNSUPP T8-3-43 AV SECOND FLOOR ROOM 25 30-OCT-14 UNSUPP UNSUPP TRUEALERTES SELF-TEST REPORT COMPLETED - Press RETURN for next Screen OR CTRL-X to abort TrueAlert ES Appliance Self-Test Individual Appliance Report Example [] CUSTOM LABEL 4-1-2 POINT ADDRESS: 4-1-2 CARD:4 CHANNEL:1 DEVICE:2 EXTENDED POWER SUPPLY UNIT NUMBER: 2 AV Type: AV RUI NUMBER: LOCAL PRIMARY STATUS NORMAL AUDIBLE GROUP CONFIG: 000 VISUAL GROUP CONFIG: 000 STYLE: INDOOR OPERATION: GENERAL EVAC CANDELA RATING 15CD COLOR LENS YES TONE TYPE BROADBAND CODING TYPE TEMPORAL VOLUME HIGH LAST TEST TIME: MON 02-JUN-14 01:00 AM LAST VISUAL TEST: NORMAL LAST AUDIBLE TEST: NORMAL LAST TEST VOLUME: NORMAL DEVICE TEST TROUBLE: NORMAL 11 S4100-0100-13 1/2016 Additional 4IOOES Data Sheet and Related Product Reference Subject Introducing the 4100ES Data Sheet S4100-0060 Subject Fire Alarm Network Overview Data Sheet S4100-0055 41 ODES Enclosures S4100-0037 Network Communications S4100-0056 41 ODES Audio and Firefighter Phone Modules S4100-0034 Network Display Unit (NDU) S4100-0102 LED/Switch Modules & Printer S4100-0032 Addressable Device Compatibility S4090-0011 Remote Annunciators S4100-0038 4009 IDNAC Repeater S4009-0004 MINIPLEX Transponders S4100-0103 Remote Battery Charger S4081-0002 Building Network Interface (BNIC) S4100-0061 SafeLINC Internet Interface S4100-0062 InfoAlarm Command Center S4100-0101 41 ODES Panels for Conventional Notification S4100-0031 Graphic I/O Modules S4100-0005 TrueAlarm Sensors S4098-0019 Truelnsight Remote Service S4100-0063 Remote IDNet Isolator S4090-0005 Agent Release Applications S4100-0040 TrueAlarm IDNet Isolator Base S4098-0025 TrueAlert ES Audible Only Appliances 549A0-0001 TrueAlert ES Weatherproof Appliances, UL Listed S49WP-0001 TrueAlert ES Visible Only Appliances S49VO-0001 TrueAlert ES Weatherproof Appliances, ULC Listed S49WP-0002 TrueAlert ApplianceIIDNAC SLC Isolator S4905-0001 TrueAlert ES Emergency Communications Appliances with Color Lenses - S49LENS 0001 TrueAlert ES Audible/Visible Appliances S49AV-0001 S S S TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. VESDA is a trademark ofXtralis Pty Ltd NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association (NFPA). ASHRAE and BACnet are trademarks ofASHRAE, American Society of Heating, Refrigeration, and Air Conditioning Engineers. Rsi in p I EX Tyco Fire Protection Products• Westminster, MA • 01441-0001 USA S4100-0100-13 1/2016 www.simplex-fire.com © 2015 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:0251 Page 1 of 4 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models 4100-9111, -9112, -9113, -9114, -9115, -9116, -9121, -9122, -9131, -9132, -9133, -9211,-9212,-9213,-9222,-9230,-9311,-9312,-9313,-9314,-9315,-9316,-9331,-9332, -9511, -9512, -9513, -9600, -9601 and -9602 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station, proprietary and central station, process monitoring, smoke control system, smoke detector monitor, emergency communication and relocation, waterfiow and sprinkler supervisory service. Suitable for releasing device service. Models 4100-9111,-9112,-9113,-9114,9115,-9116,-9121,-9122,-9211,-9212,-9213, -9222, -9311, -9312, -9313, -9314, -9511, -9512 and -9513 suitable for mass notification system as an autonomous control unit. The network display units are suitable for mass notification system system as a central control station. The remote annunciators are suitable for mass noticication system system as a local operating console. Refer to listees data sheet for detailed product description and operational considerations. System components: 4100-7101, -7104, -7113, -7115: Master Controller Assembly 4100-7105: Redundant Master Controller Assembly 4100-7150, -7151, -7152,-7154,-7156, -9833: Master Controller Replacements 4100-5005, -5015: 8-Point Class A IDC Module 4100-1291: Remote Unit Interface Module 4100-3102,-9812: MAPNET II Module 4100-3103: MAPNET/IDNET Isolator Module 4100-6038 RS-232/2120: Communication Module 4100-6014-6078: Modular Network Interface Module 4100-1293: Printer 4100-6052,-6080: Event Reporting DACT 4100-6053: Point reporting DACT 4100-6067: Contact Closure DACT 4100-6031, -6032, -9827, -9828: City Module 4100-2300, -2320: Expansion Bay 2975-9408 thru -9412: Backbox 2975-9438 thru -9440: Backbox 4100-2101 thru -2103, -2121 thru -2123: Glass Door and Retainer 4100-2104 thru -2106, -2124 thru -2126: Glass Door and Retainer *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 2 of 4 4100-2111 thru -2113, -2131 thru -2133: Solid Door 4100-2114 thru -2116, -2134 thru -2136: Solid Door 2975-9422 thru -9426, -9428, -9429: Enclosure 2975-9431, -9432: Enclosure 2975-9441 thru -9452: Enclosure 4100-0633, -6034: Tamper switch 4100-9141,-9142,-9151,-9152,-9241 thru-9246,-9342,-9352,-9542 Network Display Unit 4100-6030, -6055: Service Modem 4100-5101, -5102, -5103: Expansion Power Supply 4100-5111, -5112, -5113: System Power Supply 4100-5125, -5126, -5127: Remote Power Supply 4100-1288, -1289: LED/Switch Controller 4100-1275 thru -1287, -1295, -1299: LED/Switch Module 4100-1300, -1301, -1302: LED/Switch Module 4100-1290 24: Point Graphic I/O Module 4100-9607-9609-9610, -9611,-9612,-9614,-9615 Remote Annunciator 4100-1292: Remote LCD Display 4100-3115: XA Loop Interface Module 4100-3101,-3104, -3105, -3106, -31 07,3108,*3109,*3110,*31 11-9811 IDNET Module 4100-9116: Addressable IDNET Isolator 4090-9117: Addressable Power Isolator 4100-9643: Utility Cabinet 4100-0634,-0635-. Power Distribution Module 4100-5152, -5153, -5154, 5155: Auxiliary Power Supply 4100-6033, -9829: Alarm Relay Card 4100-3201, -3202,-3203,-3204,-3206: Auxiliary Relay Modules 4100-0620: Basic Transponder Interface Card 4100-6043, -6044: Converter 4100-6045: Decoder Module 4100-6054: Fiber Optic Driver 4100-5115: Expansion NAC 4100-9816: Master Clock Interface 4100-6048: VESDA Interface 4100-5311,-5313,-5325,-5327: Extended Power Supply 4100-6103: Dual Class A Isolator 4100-5120, -5121, -5122: True Alert Power Supply 4081-9306, -9308: Expansion Battery Charger 4100-2140: Rack Mount Bay Mounting Kit 4100-2144: Rack Mount PDM Mounting Kit 4100-0156: Eight Volt Converter 4100-0625: Local Mode Transponder Interface Card 4601-9100, -9108,-9109,-9110,-9111 Local Mode Controller 4100-0623: Basic Network Transponder Interface Card 4100-0621, -0622, -1341 :Audio Riser Module 4100-6036, -6037,-6101,-6102: Physical Bridge Assembly *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 3 of 4 4100-9849, -9863: TCP/IP Physical Bridge Assembly (Style 4) 4100-9850, -9864: TCP/IP Physical Bridge Assembly (Style 7) 4100-6056.- Wired Media Card 4100-6057: Fiber Optic Media Card 4100-9620: Analog Audio Expansion Bay 4100-9621 : Digital Audio Expansion Bay 4100-1210: Analog Audio Controller Card 4100-1211, -1311: Digital Audio Controller Card 4100-1212 thru -1225, 1261, -1262 Analog Audio Amplifier 4100-1312 thru -1325, -1361, -1362 Analog Audio Amplifier 4100-1226 thru -1239, 1263, -1264 Digital Audio Amplifier 4100-1326 thru -1339, -1363, -1364 Digital Audio Amplifier 4100-1240: Audio Input Option Card 4100-1241, -1242: Message Expansion Card 4100-1243,-1244: Microphone Module 4100-1245, -1248, -1266: Amplifier Expansion NAC 4100-1246, -1249, -1267: Amplifier Class A Adapter 4100-1252, thru -1255 :Audio Operator Interface Module 4100-1270: Master Telephone Assembly 4100-1271 : Remote Telephone 4100-1272: Expansion Phone Card 4100-1273: Telephone Class A Adapter 4100-5116: Expansion Signal Card 4100-1259, -1260, -1268: Constant Supervision NAC Modules 4100-1265: Degrade Fail-Safe Microphone Module 4100-6068: TFX Interface Module 4100-6072, 6073, 6074, 6075: Fiber Optic Modem S 4100-9842: Fiber Modem Audio Expansion Board 4100-9901 thru -9926, -9930 thru -9939Retro-fit Kits 4100-7153,-7155: Display Replacement 4100-9401, -9402, -9441, -9442: Remote User Interface 4100-0640: FUI Controller Memory Add-on Module 4100-7157: Expanded Memory CPU Card 4100-6065: BMUX Communication Card 2081-9046: Coil Supervision Module 4100-6066: TFX Loop Card 4100-5130: TFX Voltage Regulator Module 4100-1340: TFX Audio Interface Module 4100-1297: TFX Phone Card 4100-1298: TFX Master Telephone with Phone Card 4100-6069: BACpac Ethernet Module 4100-1274: Microphone Multiplex Module 4100-6047: Building Network Interlace Card 4190-6104: Remote Service Gateway RATING: 120, 220, 240 VAC primary; 24 VDC secondary *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7165-0026:0251 Page 4 of 4 INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model/catalog number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units suitable for use with separately listed compatible initiating and indicating devices. Also Suitable for high-rise applications. The control unit is compatible with the Model 4090-9007Signal Individual Addressable Module (CSFM Listing No. 7165-0026:318). These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. This control unit meets the requirements of UL-864, 9th Edition Standard. NOTE: 1. For Fire Alarm Verification feature (delay of the fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. 2. Combined from 7170-0026:250 S *Rev. 09-05-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 4090-90108 A IDNet Relay lAM Package (shown approximately 1/2 size) OMNI [.] iii Communications IDNet communications, 1 address per device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type - Separate contacts; 1, NO and 1, NC Maximum Voltage I 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 Mm 2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 %"H x 4"W x 1 D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) fiSimplEx S UL, ULC, CSFM Listed, FM Approved* I'I1! I (-1 Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow 5 LED to be viewed after installation UL listed to Standard 864 I flstrintinn 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Model Description 4090-9010 18 A Relay lAM Optional Trim Plates and Adapter Model Description 4090-9801 For semi-flush Trim plate, galvanized mounted box steel, with LED viewing 4090-9802 For surface window; includes mounted box mounting screws S 4090-9813 Adapter plate to fit 11/16 (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Application Peripherals IDNet Communicating Devices Model 4090-9010, 8 A Relay lAM S4090-0015-1 11/2014 8 A Relay lAM Mounting Information 7 7 7 7 7 7 7 7 7 7 7 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate J © ©111 © © LITIIi Add supplied label to— - -J I uit, ,I tT ri cover on-site if controlling IAvTISsEJV41-I 4-9/16" 120 or 240 VAC 4-5/16" (116 mm) (109 mm) Light pipe for LED viewing © ©U © © -- 4 4-9/16(116mm) 4 4-5/16" 009 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited ®S i M p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4090-0015-1 11/2014 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as ofdocument revision date ant/are subject to change without notice. [I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0223 Page 1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models* 4090-9001, -9001TSP, -9001TTP, and -9051 Supervised lAM Monitor Module; 4090-9002, -9002TSP, and -9002TTP lAM Relay Module; 4090-9106, -9106TSP, and-9106TTP Class "A' ZAM Initiating Module; 4090-9101, -9101TSP, and -9I01TTP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24 VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. NOTE: S *Recel.t 03-29-2006 jw This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division 55im plEx lrueAlert Addressable Notification Appliances S UL, ULC, CSFM Listed, FM Approved; P1 Multi-Candela Visible Only (V/O) MEA (NYC) Acceptance* LJf Appliances (Strobes), Ceiling Mount C I !1ti i *i Individually addressed and controlled multi-candela VIO (visible only) notification appliances provide: Multi-candela xenon strobe with synchronized 1 Hz flash rate and with intensity programmable from the control panel or jumper selected as 15, 30, 75, or 110 cd Advanced addressable notification controlled by IDNAC SLCs providing regulated 29 VDC allowing strobes to operate with lower current even under battery backup Wiring supervision to each strobe allowing "T-tapped" connections for Class B circuits to simplify wiring (Class A circuits require in/out wiring) TrueAlert Device Reports at the control panel detailing appliance point ID, custom label, type, and candela setting (see sample on page 2) Magnet test diagnostics to assist checkout and testing of appliances and wiring Compatibility with ADA requirements Compatibility with legacy TrueAlert addressable systems for upgrade and replacement (see page 3) UL listed to Standard 1971 and TJILCS526* LED indicator and magnet test feature: Appliance LED can be selected to display each polling cycle to indicate appliance supervision In diagnostic mode, the magnet test pulses the LED to indicate appliance address AND pulses to indicate the intensity selection; a brief output of the strobe is also selectable to confirm operation Mechanical design features: Rugged, high impact, flame retardant ceiling mount thermoplastic housings are available in red or white Rear of housing does not extend into box and easily mounts to standard electrical boxes Mounting options include red wire guards and adapters for surface mounted electrical boxes * See page 2 for wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:235 for allowable values and/or conditions concerning material presented in this document. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. Ceiling Mount Addressable V/Os I'[*f .11 riri Multi-Candela TrueAlert addressable strobes provide convenient installation to standard electrical boxes. The strobe is individually addressed and individually controlled with power, supervision, and control supplied from a Simplex fire alarm control panel providing IDNAC Signaling Line Circuits (SLCs). (See compatibility list on page 3.) 14 It.] iI7i!j.]II*14I.1i1 U4E1]1161I Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117. 1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert addressable appliances on IDNAC SLCs provide separate visible (and audible) notification using a single two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current allows efficient IDNAC SLC operation. With IDNAC SLCs, a constant 29 VDC source voltage is maintained, even during battery standby, allowing strobes to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, or support for more appliances per IDNAC SLC, or use of smaller gauge wiring, or combinations of these benefits, all providing installation and maintenance savings with high assurance that appliances that operate during normal system testing will operate during worst case alarm conditions. S4906-0004-4 2/2015 Description Multi-Candela Addressable Strobe; intensity selectable as: 15, 30, 75, or 110 candela C II ']Lt41 Reducing Installation and Testing Time. With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be '7" tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. (Refer to data sheet S4905-0001 for additional information.) Test Features. Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test. In this test mode, in response to the magnet test, the appliance LED pulses sequentially to conveniently indicate the appliance's address. Operational Appliance Testing. In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT). The 2nd generation of the Simplex TrueStart Test Instrument adds testing of IDNAC SLC wiring and TrueAlert (and TrueAlert ES) appliances to its ability to test IDCs, NACs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. Product Selection Multi-Candela Ceiling Mount Addressable Strobe Housing Model Color FIRE Lettering 4906-9202 Red I White I 4 %' x 2 /16" x 2 %" D 4906-9204 White Red (121 mm x 75 mm x 67 mm) Dimensions VIO Adapters (see diagram on page 3) Model Description Dimensions 4905-9910 Ceiling Mount, Surface Mount Adapter Plate, zinc plated; required for 4%' x 3%"(124 mm x 79 mm) ceiling surface mount Wire Guards (see diagram on page 3) Model Description Dimensions 49059926* Ceiling Mount Red wire guard with mounting plate, compatible with 6 %' x 4 %" x 2 /8" semi-flush or surface mounted boxes (156mm xlii mmx 73mm) * UL listed by Space Age Electronics Inc. TrueAlert Device Reports Reference Service REPORT 5 Port : TrueAlert Device Report Page 1 12:34:56am TUE 27-Jan-15 DEVICE POINT ID CUSTOM LABEL TYPE CANDELA T14-1-1 Location Label . . . up to 40 characters V/0 15 T14-1-2 Break Room 5 A/V 110 T14-1-3 Boiler Room A/V 75 T14-1-4 Elec. Room 7 A/V 30 2 S4906-00044 2/2015 S Ceiling Mount V/O and Guard Installation Reference Bottom view __ Magnetic test location LED indicator/ Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard Ceiling mount strobe Optional 4905-9926 wire guard with mounting plate ---------------------------------------- Strobe intensity viewing slot (JT__Intensity selection plug, [_J I accessible only from rear of lens \_,/ housing; factory setting is FACP, controlled bypanel Single gang box (Wiremold V57445) 2-1/4" (57 mm) deep, supplied by others Address setting DlPswitch is behind strobe assembly, select address and strobe candela setting before inserting into housing S IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Reference Controller Output IDNAC SLC Output Voltage Appliance Voltage Design Reference 41 DOES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4007E5 with IDNAC Notification S4007-0002 4010ES with ESS Enhanced System Supply S4010-0011 Specifications General Specifications (see page 2 for dimensions) Environmental 32° to 122° F (0" to 50° C); 10% to 93%, non-condensing at 1000 F (38" C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wirina Installation Instructions 579-808 Strobe Specifications Typical Operating Voltage Range 23 VDC to 31 VDC, Special Application (see below for 17 VDC rating) Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 46 synchronized strobes maximum per NAC Candela Setting 15 c I 30 c I 75 c I 110 c 23 VDC RMS Current Ratings, for connection to IDNAC Addressable SLCs 60 mA 92 mA 180 mA 240 mA TrueAlert Strobe LEGACY Compatibility Reference Compatible Controller Data Sheet Controller Output Available Strobe Appliance Voltage Reference Intensity Minimum 4100ES or 4100U with TrueAlert Power Supply S4100-0031 TrueAlert 15, 30, 75, and 17 VDQ 4009 TPS, Remote TrueAlert Power Supply S4100-0037 Addressable SLC 110 c TrueAlert Addressable Controller (4009T) S4009-0003 Electrical Ratings Difference for Retrofit Applications Voltage Range 17 VDC to 31 VDC, Special Application Candela Setting 15 c 30 c 75 c 110 Cd 17 VDC RMS Current Ratings, use when connected to TrueAlert Addressable SLCs per 76 mA 128 mA 242 mA 328 mA above S4906-0004-4 2/2015 S S TYCO, SIMPLEX and the product names listed in this material are ,narks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). B®S i rn p1 EX Tyco Fire Protection Products • Westminster, MA 01441-0001 USA S4906-0004-4 2/2015 © 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revcian date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL , - R1, FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0235 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models "TrueAlert non-addressable "4904-9331, 4904-9342, 4904-9332, 4904-9343, 4904-9333 and 4904-9344 synchronized strobe lights. Models "TrueAlert non-addressable "4904-9168,4904-9171,4904-9169,4904-9172, 4904-9170 and 4904-9173 non-synchronized strobe lights. Models "TrueAlert addressable" 4904-9350, 4904-9351, 4904-9352, 4904-9353, 4904-9354, 4909-9355 synchronized strobe lights. Models "TrueAlert addressable" 4904-9356, 4904-9357, 4904-9358, 4904-9359, 4904-9360, 4909-9361 synchronized strobe lights. Models "TrueAlert addressable" 4906-9201, -9202, -9203, -9204, and -9208 synchronized multi-candela strobe lights are intended for indoor use. *Models 4906-9201, -9203 and -9208 are intended for wall mounted only. *Models 4906-9202 and -9204 are intended for ceilingl mounted only. Intended for use with either Model 4209-9401 NAC Extender or with the TrueAlert power supply of Model 4100U fire alarm control panel. Model 4906-9208 employs two lenses, clear lens for "Fire" and amber for "Non-Fire". Model 4905-9938 sync control module. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 4904-9331, -9342, -9350, -9353, -9356, -9359, -9168, -9171: 15cd, 1 Hz. 4904-9332, -9343, -9351, -9354, -9357, -9360, -9169, -9172: 75cd, 1 Hz. 4904-9333, -9344, -9170, -9173, -9352, -9355, -9358, -9361: 110cd, 1 Hz. Models 4906-9201, -9202, -9203, -9204, -9208: 15, 30, 75, 110cd, 1 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner, acceptable to the authority having jurisdiction. Intended for indoor use and wall mounting only. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as strobe lights suitable for the hearing impaired when used with listee's separately listed fire alarm control units. For "TrueAlert non-addressable" synchronized strobes, Model 4905-9938 sync control module must be used. "Rev 04-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division "~O' 0,00 0 00 000 000000 0 00 1.10 Z-9-9 ".",~1101-0-.,-,O--00-.Oo.o0.0--ool-o~"0.0.0,-O.O0000-~~ 0000000óo' 000000000c 0000000000 000000000c 000000000, UQUJU o0 000000o 000 \ oo0000o00 \00000 00000 0 \ 000oQ00000i \ 0 0 0000000 d0000) 00 >000000 0.. 0, )00000 000000 000o0000000b0000 000 )0000000 00000 D 0000 e 0 0 0 n 000 B®Si rn plEx TrueAlert Addressable Notification Appliances S UL, ULC Listed* [11 Ceiling Mount Addressable Speaker Visible Lf.fJ i (SN) Notification Appliances Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel 1DNAC Signaling Line Circuit (SLC). S/V notification appliances use a multi-tapped speaker for audio/tone notification and a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. Wiring supervision is electronically monitored and allows audio wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Ceiling mount speaker visible appliances are available in 400 - 4000 Hz models and high fidelity models capable of operating between 200 - 10000 Hz. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWC-000 1. S Ceiling Mount Addressable Speaker/Visible Notification Appliance -dimt Slttit Ceiling Mount Addressable Speaker SN Appliances TrueAlert ES Addressable S/V appliance dimensions with cover: 8 1/8 H x 7 %" W x 3" D (206 mm x 180 mm x 76 mm) Model I Description 49SV-APPLC(-BA) I Speaker Visible appliance only. Select cover separately. High Fidelity Appliances Model Description 49HFV-APPLC(-BA) I High Fidelity appliance only. Select cover separately. High Candela Appliances 49SVH-APPLC(-BA) I High Candela appliance only. Select cover separately. - High Fidelity High Candela Appliances Model Description 49HFVH-APPLC(-BA) High Fidelity High Candela appliance. Select cover separately. 49HFVH-APLCA-BA High Fidelity High Candela appliance with amber colored lens. Select cover separately. 491-lFVH-APLCB-BA High Fidelity High Candela appliance with blue colored lens. Select cover separately. SN Covers (Required when ordering APPLC models) Model Color lWording Model Color Wording 49SVC-CRALT Red ALERT 495 VC-C WALT White ALERT 49SVC-CRBA j-/FIRE 49SVC-CWBA Li-/FIRE 49SVC-CRBC */FIRE ALARM 495VC-CWBC Y/FlRE ALARM 49SVCCRBF FEU/FIRE 49SVCCWBF FEU/FIRE 495VC-CRFEU FEU 49SVC-CWFEU FEU 49SVC-CRFIRE FIRE 495VC-CWFIRE FIRE 49SVC-CRS Simplex logo only 495VC-CWS Simplex logo only 49SVC-CK Back No logo or lettering Note: (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in —BA are assemoieci in tne UA * Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire S49SVC-0001-1 11/2015 IDNAC SLC Controller Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SLC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 IDNAC SLC 29 VDC (regulated) 23 VDC (with 6 VDC drop) 4009 IDNAC Repeater S4009-0004 4100ES Flex 35, 50, and 100 Amplifiers S4100-0034 4100ES Constant Supervision and Signal Cards tin u i11TIrniA&.i. liUi.i Specifications (see page 1 for appliance dimensions) Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm'); two wires per terminal for in/out wiring. Use Unshielded Twisted Pair (UTP) for IDNAC and audio wiring. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Installation Instructions 579-1203 (49SV, 49SVH and 49HFV models) 579-1206 (Amber/Blue 49HFVH model) Speaker General Specifications Input Voltage 25 or 70.7 Vrms PowerTaps Ya,%,1, and 2W 400 to 4000 Hz (SN, SNH), 200 to 10000 Hz General Signaling = 125 to 12 kHz Frequency Response (H/F, HFNH) Speaker Output Ratings 25 or 70.7 Vrms @ 10 ft (3 m) Wattage Tap Model 1/2 W 1W 2W SN H/F SN H/F SN H/F SN H/F Reverberant Chamber Test, per UL 1480 (dBA) 79 76 83 80 86* 84 89° 87° Anechoic Chamber Test, per ULC-S541 (dBA)° 79 78 83 82 86* 85* 1 89* 88* . Select taps as indicated to satisty the ULU tire alarm applications requirement of 85dBAminimum Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Attenuation _Angle __Attenuation _Angle Testing) -3 dB 70° -6 dB 80° output at room temperature Angle On-Axis ____________ Vertical, Below Axis Horizontal, Left/Rig htof Axis 0° I_100% 45°I 90° 45°I90° UL required output 45%I_25% 45%I_25% Typical output I_327% 134%I_83% 129%.1 Appliance peciricatuons OperatingVoltageRange 23VDCto30VDC,SpecialApplication SupervisoryRequirements 1 unit load (=_0.8mA control panel current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit,max127SNappliancesperIDNACchannel CandelaSetting Current consumption** 49SV and 49HFV models 49SVH and 49HFVH modelslN/A l5cd I_30cd I_75cd 110Cd _135cdI185 Cd 59mA I_82mA I_145mA 1 193 m I_N/A I_N/A I_N/A ] 235mA _N/A _255mA I_295mA -- ivieasurea at z6lvuL. on IUN/\I. /oaressaoie LU Note: Speakers are for connection to compatible fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. 2 S49SVC-0001-1 10/2015 S S Ceiling Mount S/V Installation Reference Appliance with cover (front) "-7 ( / w' Magnet test location / / 0 indicated by area that j o is not textured CO OOOO.O-KAOOOO 00000 110 0000000,00 000000 10%'0 0000000000 00000000MID.10 00000000 Appliance test points, audio circuit power taps, J 00000000,00 0 000000000 0 00 and address dip switch \00000000 0 Set audio circuit power taps and \ '.' device address before fixing \ El Wiring terminals for speaker fl and strobe connections accept 2 #12-18 AWG wires 10 set candela manually, set 10 '\ the flag to the desired : 75 candela rating.' 30 15 Use slotted screwdriver FACP here to remove cover S S 3 S49SVC-0001-1 10/201 S Mount 1o4" X 4" X 2-1/8" Appliance (rear) electrical box using 8-32 screws Note: Ceiling mount only cover UI Candela flag setting Set flag to FACP to control candela rating from an FACP providing IDNAC notification. S S S TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). - Tyco Fire Protection Products. Westminster, MA • 01441-0001 USA S49SVC-0001-1 11/2015 %S I M EX www.simplex-fire.com 02015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: SimplexloO Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: jgoyette@tycoint.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,495V-APPLC-BA,49HFV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,495V-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 49SV-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF and 49HFV-WRF True Alert ES, Addressable wall mounted Speaker/Strobes. Models: 4950-APPLC, 49HF-APPLC, 4950-APPLC-BA, 49HF-APPLC-BA,4950-CW and 49HF-CW True Alert ES, ceiling mounted Speakers. Models: 49S0-APPLW, 49HF-APPLW, 49S0-APPLW-BA, 49HF-APPLW-BA,49S0-WRF and 49HF-WRF True Alert ES, wall mounted Speakers. Models: 49SVC-CK,49SVC-CRALT,49SVC-CRFI RE,49SVC-CRS,49SVC-CRBC,49SVC-CWBC, 49SVC-CWFI RE,49SVC-CRFEU,49SVC-CRBF,49SVC-CWALT,49SVC-CWBA,49SVC-CRB A,49SVC-CWS,49SVC-CWBF and 49SVC-CWFEU True Alert ES, Speaker/Strobe Ceiling Mount Dress Covers. Models: 49SVC-WRALT,49SVC-WRBA,49SVC-WRBC,49SVC-WRBF,49SVC-WRFEU,49SVC-WRFI RE,49SVC-WRS,49SVC-WWALT,49SVC-\WVBA,49SVC-W1VBC,49SVC-WVBF,49SVC-W WFEU,49SVC-W\NFIRE and 49SVC-WWS True Alert ES, Speaker/Strobe wall Mount Dress Covers. Models: 49S0C-CWFI RE,49S0C-CRFIRE,49SOC-CRS,4950C-CWS,49S0C-CK,49S0C-CR, 4950C-CW,49S0C-CWALT and 49S0C-CRALT True Alert ES, Speaker Ceiling Mount Dress Covers. 12-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff the test results and/or other data but does not make an independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division Listing No. 7125-0026:0384 Page 2 of 2 Models: 49S0C-WRFEU ,49S0C-WRBF,4OSOCWRBC,49S0C-WRBA,49S0C-WWS,49S0C-WWFI RE,49S0C-WRBLANK,49S0C-WRFIRE,49S0C-WRS,49S0C-WJVBA,49S0C-WJVBC,49S OC-\MNBF,49S0C-WAfFEU,49S0C-WAfBLANK,49S0C-\MNALT and 49S0C-WRALT True Alert ES, Speaker Wall Mount Dress Cover. Models: 49MP-SVWR,49MP-SVWW,49MP-SOWR and 49MP-SOVWV True Alert ES,Back Plates. Models: 49SV-LENS-AMBER,49SV-LENS-BLUE,49SV-LENS-RED and 49SV-LENS-GREEN True Alert ES, Colored Lens Kit. Refer to listee's data sheet for detailed product description and operational consideration. RATING; 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signalling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. S 12-08-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2016 Listing Expires June 30, 2017 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division tqccs ell License Number 986047 SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com SIMPLEXGRINNELL LP 12728 SHOEMAKER AVENUE SANTA FE SPRINGS, CA 90670 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2017 This license is current and active. All information below should be reviewed. dO - ELECTRICAL C16 -FIRE PROTECTION CONTRACTOR Contractor's Bond This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 10/01/2016 Bond of Qualifying Individual This license filed Bond of Qualifying Individual number 82332031 for MAYLE RONALD GILBERT in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82332035 for ROSTEN TIMOTHY PAUL in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC308342 Effective Date: 10/01/2016 Expire Date: 10/01/2017 Workers' Compensation History 10/4/2016 REV.#: 0 PROJECT #: 480-XX)O(XX-XX I X)000000(X tq!;0 SimplexGrinnell SimplexGrinnell LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.simplexgrinnell.com S SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: 8:00AM TO 17:OOPM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST S 10/4/2016 REV.#: 0 PROJECT #: 480-XXXXXX-XX I XXXXXXXXX