Loading...
HomeMy WebLinkAbout2525 EL CAMINO REAL; 268; FPC2019-0271; PermitPERMIT REPORT city of Carlsbad Print Date: 02/03/2022 Permit No: FPC2019-0271 Job Address: 2525 EL CAMINO REAL, #268, CARLSBAD, CA 92008-1210 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 1563022700 Valuation: $0.00 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Applied: 12/09/2019 Issued: 03/16/2020 Finaled Close Out: 08/19/2021 Inspector: Final Inspection: Project Title: Description: LE FUN LAND -FIRE ALARM TI (ADDRESSABLE, 11 DEVICES) Applicant: FPContractor: JOHNSON CONTROLS FIRE PROTECTION LP JOHNSON CONTROLS FIRE PROTECTION LP DOUGLAS DANIELS P0 BOX 3042 3568 RUFFIN RD BOCA RATON, FL 33431-0942 SAN DIEGO, CA 92123-2597 (561) 341-7780 (858) 633-9123 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov FPC2JD(9 -c2 -( Johnson Controls 3568 Ruffin Road, South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci.com Fire Detection and Alarm System Product Submittal Project: Le FunLand The Shoppes at Carlsbad 2525 El Camino Real Suite 268 Carlsbad, CA 92008 For any questions regarding this submittal, please contact Douglas Daniels, 858- 633-9123 or douqlas.daniels(ãici.com 11/13/2019 REV.#: 0 PROJECT 1 Johnson Controls 3568 Ruffin Road, South Johnson San Diego, CA 92123-2597 Controls Tele: (858) 633-9100 Fax: (858) 633-9101 www.jci. corn Fire Detection and Alarm System Products Qty Model No. Description C.S.F.M. No. 1 4098-9755 Duct Detector 3240-0026:0241 1 2098-9806 Remote Test Switch 7300-0026:0150 2 4090-9010 Relay lAM 7300-0026:0311 1 49V0-APPLC Strobe 7125-0026:0373 3 49SV-APPLC Speaker Strobe 7125-0026:0384 Business Information 11/13/2019 REV.#: 0 PROJECT LI !3®Simplex TrueAlarm® Analog Sensing UL, ULC, CSFM Listed; FM Approved,, Addressable Duct Sensor Housings with TrueAlarm MEA (NYC) Acceptance* Photoelectric Sensor; Available with Multiple Relay Control I1I!It* Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: Individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via mNetTM or MAPNET H®, 2-wire communicationst Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by IDNet!MAPNET II communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC; includes one relay Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interlace board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) 4098-9843 remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. o on man 0000 0 0 I100D Duct Sensor Housing, Front and Bottom View 0 2098-9808 2098-9806 Remote Status/Alarm Indicator and Test Station dtittie Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. IIj11liiI1o]6]g,IJ0Ic]tHTi1j1 Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarm sensors and IDNet and MAPNET II communications are protected by one or more of the following U.S. Patents: 5155,468; 5,173,683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; D383,407; 0388,352; D392,573; 4,796,025. S4098-0030-5 3/2007 irri 1111 I1ifs1g9I0I ttv7Tm1irj Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) I iTi1T1 F9 TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Photoelectric Sensing (Continued) Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. i-ire iarm ontroi i-'anei 1-eatures Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity Automatic environmental compensation Smoke sensitivity is displayed in percent per foot Ability to display and print detailed sensor information in plain English language Relays of model 4098-9756 are under panel control I .irri ror ON, OF r, or override Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility Basic Duct Sensor Housing; operating power is supplied by Simplex fire alarm control panel models 4010, ( 4020, 4100, 4100U, 4120. Also 2120 CDT if 4098-9756) and either lDNet or MAPNET Il communications (no relay output) configured for MAPNET Il, TrueAlarm operation Duct Sensor Housing with supervised multiple relay output, Same as above except relay operation is not compatible with 2120 CDT; 4098-9756 requires separate 24 VDC fire alarm power and 4081-9008 end-of-line resistor harness; includes one 4098-9843 relay Relay output is for up to 15 total 4098-9843 Relays (additional relays are ordered separately) Remote LED Indicator and Test Station, Select One if Required Model Description Compatibility Mounting 2098-9808 Red LED status indicator Use single gang box, 4098-9755 Test Station with keyswitch and red LED status indicator 4098-9756 3"Hx2"Wx2"D 098-9806J (turning switch to TEST" initiates alarm for system testing) (76 mm x 51 mm x 51 mm) Epoxy Encapsulated Remote Relay and End-of-Line Resistor Model Description Compatibility Location Relay; single Form C (7 A @ 120 VAC); refer to pages 3 and 4 4098-9756 only; Locate relays within 3 ft 4098-9843 for additional relay information; one included with 4098-9756; (1 m) of device being connect up to 15 wiring is 18 AWG (0.82 mm2) color coded wire leads controlled per NFPA 72 4081-9008 End-of-Line Resistor Harness; 10 kQ, 1/2W; (ref. 733-894); 4098-9756 At last relay location required to supervise remote relay coil connection * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2" (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2" (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2' (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2" (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2" (51 mm) longer than duct width S4098-0030-5 3/2007 supplied for unused hole J 0UUDDt1U •© II o.— ,01 Dopt_______________ '1 o n-auo oo Yellow LED, relay control trouble indicator (4098-9756 only) 0 Redsensor 0 D s LED FSde ofducD.._., 5i © III Wiringtermina15J netic test area \ Mount as shown (preferred) or with electronics area located to d sensor area J the LEFT or UP ONLY (171 mm) Sampling tube access hole screws IBM 1I4ijD] : rin ri .r II NOTE: Refer to Installation Instructions 574-776 for additional detail and maintenance information. 1 4 11-3/8" (289 mm) 101 moe sensor, m in interfacebase(sul Metal plate with dual holes for 3/4 (19 mm) conduit, plug 3-3/8" (86 mm) 13/16" (21 mm) ' provided sampling tube, ordered Test ports (2) for measuring airflow 1 [separately per duct width and for aerosol injection Exhaust tube (supplied) Duct wall End View with Duct and Tubes 18" Round duct outline' DucthousingJ (minimum diameter) 1"1haust tube _,,_[8 Square duct outline1 — I (minimum width) SarnpHng tube, keyed for proper hole alignment with holes facing into airflow (template is provided for proper tube installation) 4098-9843 Remote Relay (7 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72 (38 mm) _., 1-3/16" (30 mm) 3 S4098-0030-5 3/2007 Ii1rr1ii mI.] ir;i Exhaust Sensor Damper OK Exhaust -LI —Return Air Do not locate sensor here Return air damper Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. Fresh Supply air Air Filter " Sensor Do not locate bank OK sens Bend or other here obstruction Return ai"' widths minimum 6 Duct inlet 6 Duct widths minimum Specifications General Mechanical and Environmental Air Velocity Range (linear ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alarm LED and Test Station with Remote Alarm LED Current Black base with clear cover Remote Status/Alarm LED 1.2 mA, no impact to 24 VDC alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to 24 VDC alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 It (76 m) maximum Addressable Operation Data Communications IDNet or MAPNET II communications, auto-select, one address per housing; I provides operating power to model 4098-9755 Model 4098-9756 with Supervised Multiple Relay Control, Requires Separate Fused 24 VDC from Fire Alarm Power Supply Input Voltage 18-32 VDC (24 VDC nominal) Standby Current 13 mA @ 24 VDC Alarm Current (one relay activated) 115 mA @ 24 VDC; add 15 mA for each additional remote 4098-9843 relay For use with 4098-9843 relay only, quantity of 15 maximum; distance of 500 ft Supervised Remote Relay Control Output (152 m) maximum; requires 4081-9008 (ref. 733-894) 10 k, 1/2 Wend-of-line resistor 4098-9843 Relay Output Ratings, Single Form C, use with Model 4098-9756 Only Coil Current Relay Contacts 15 mA @ 24 VDC, up to 15 maximum per relay control 7Aat 0.35 PF@28 VDC& 120 VAC 250 iA © 5 VDC Location Distance I 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device I being controlled per NFPA 72 Tyco, Simplex, the Simplex logo, TrueA farm, IDNel, and MAPNETJI are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). .Simplex Tyco Safety Products Westminster• Westminster, MA 0 144 1-0001 • USA S4098-0030-5 3/2007 www.tycosafetyproducts-usa-wm.com 0 2007 Tyco Safefy Products Westminster. All rights reserved All specflcations and other information shown were current as ofdo cument revision dote and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 3240-0026:0241 Page 1 of 1 CATEGORY: 3240 -- DUCT SMOKE DETECTOR HOUSING/BASE LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4098-9755, *4098975515p *4098.9755TTp 4098-9756, *4098975615p *4098..9756TTp 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0150 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplex100 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette©jci.com DESIGN: Models 2098-9805, -9806, -9808, -9744 and 4098-9830 remote alarm indicator; Model 4098-9835 remote power/alarm indicator with test switch; Model 2098-9816 remote power/alarm/trouble indicator; Model 4098-9834 remote alarm indicator with test switch. Refer to listee's data sheet for detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote indicators or use with separately listed compatible detectors and control units. Models 2098-9805, -9806, -9808, -9744, and 4098-9834, -9835 are intended for use with duct smoke detectors. Model 2098-9816 is intended for use with projected beam detector systems. NOTE: *Rev. 05-12-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct IV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CAST!L.LO, Program Coordinator Fire Engineering Division 5SimpIEx Multi-Application Peripherals UL, ULC, CSFM Listed; IDNet Communicating Devices FM Approved* Model 4090-9010, 8 A Relay lAM I11!i(*I Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of separate, 8 A Normally Open (Form A, NO) and 8 A Normally Closed (Form B, NC) contacts Low power latching relay design allows IDNet communications to supply both data and module power Operation upon loss and restoration of communications is switch selectable to either reset the output relays to normal or to keep them latched in the selected state For use with following Simplex® control panels: Model Series 4007E5, 4008, 4010, 4010E5, 4100ES, and 4100U fire alarm control panels for IDNet communications Compact construction: Mounts in standard 4" (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 1i/ square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications, can be selected at panel to indicate activated state Optional 4" square box covers are available to allow LED to be viewed after installation UL listed to Standard 864 I.I4.-1IIllr1 8 A Relay lAMs allow fire alarm control panels to control a remotely located NO and NC contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. IMIfl!11 Model Description . (4090-9010j BA Relay lAM Optional Trim Plates and Adapter Model I Description 4090-9801 For semi-flush I Trim plate, galvanized mounted box I steel, with LED viewing For surface window; includes 4090-9802 mounted box mounting screws 4090-9813 Adapter plate to fit 4 11/16 (119 mm) square electrical box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:0311 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9010 8 A IDNet Relay lAM Package (shown approximately 1/2 size) IDNet communications I address per Communications device Relay lAM Power Supplied by IDNet communications Installation 579-1063 Instructions Contact Ratings* (not rated for incandescent switching) Type Separate contacts; 1, NO and 1 NC Maximum Voltage 250 VAC or 30 VDC Ratings Current Ratings 8 A, resistive 3.5 A, inductive at 0.35 PF * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120/240 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) Up to 2500 ft (762 m) from control panel IDNet Communications Up to 10,000 ft (3048 m) total wiring Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4W' H x 4" W I Ye" D (105 mm x 102 mm x 35 mm) Mounting Plate Sheet metal, galvanized Temperature 32° to 120° F (0° to 49° C), Range intended for indoor operation Humidity Range I Up to 93% RH at 100° F (38° C) S4090-0015-1 11/2014 8 A Relay lAM Mounting Information INS 4" (102 mm) square box, 2-1/8' (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate © © © © Add supplied label wARNNa I AvERnssaEp4rI cover on-site if controlling IAvnssaJim, eli:NRLI am I 4-9/16" 120 or 240 VAC 4-5/16" (116 mm) ('09 mm' Light pipe for LED viewing © © 1 [© © 4-9/16" (116 mm)— 4-5/16" (109 mm) 4090-9801, Trim plate for 4090-9802, Trim plate for semi-flush mounted box surface mounted box Optional Trim Plates for Visible LED TYCO, SIMPLEX and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. ®S i rn p1 EX Tyco Fire Protection Products• Westminster, MA 01441-0001 • USA S4090-0015-1 11/2014 www.simplex-fire.com 0 2014 Tyco Fire Protection Products. All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:0311 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models 4090-9118 relay lAM (individually addressable module) module, 4090-9119 relay lAM module with unsupervised feedback, 4090-9008 dual relay lAM, *40909010 eight amp relay lAM and 4090-9120 six-point I/O module. (lAM). Refer to listee's data sheet for detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 04-24-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division £ SimplEx TrueAlert ES Addressable Notification Appliances UL, ULC, CSFM Listed; FM Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Approved Description Ceiling Mount Addressable Visible (VIO) Notification Appliances are individually powered, addressed, and controlled from a Simplex fire alarm control panel IDNAC signaling Line circuit (SLC). WO notification appliances use a multi-candela strobe with synchronized 1 Hz flash rate and selectable candela rating. LED and Xenon tube strobes devices are interoperable on the same IDNAC channel, separate appliance and cover selection greatly simplifies the ordering and installation process. Features Individually addressed Visible Only (WO) notification appliances Multi-candela LED strobe available in low (15, 3075 and 113 cd) and high (110, 135 and 185 cd) range candela models. Small compact design and low current draw due to energy efficient Xenon tube strobes, with LED indicators. Advanced addressable notification controlled by IDNACSLCs. IDNAC SLCs provide regu1ated29 VDC allowing horns to operate with lower current Electrical test point access by removing the cover Strobe intensity can be programmed from the control panel or the device Wiring supervision to each appliance allows I-tapped connections for Class B circuits to simplify wiring (class A circuits require in/out wiring) Self-Test Mode allows on-board sensors to detect the strobe output and then report their status to the control panel TrueAlert Device Reports at the control panel detail appliance point ID, custom label, type, and candela setting Magnet test diagnostics assist checkout and testing of appliances and wiring Compatibility with ADA requirements Strobe operation is listed to UL Standard 1971 and ULC Standard S526 synchronized strobe operation on its IDNAC channel. LED Indicator and Magnet Test feature: Indicator LED indicates magnet test acknowledgment, 3 digit IDNAC address, and candela rating Indicator LED can be configured to blink every polling cycle :o indicate appliance supervision When the controller is in diagnostic mode, the magnet test pulses the Indicator LED to indicate appliance address and can be set :0 also briefly flash the strobe LEDs Mechanical design features Rugged, high impact, flame retardant thermoplastic housing in red and white colors Various covers and lettering options available - Red with white letters or white with red letters covers can be easily removed without disturbing the connected housing and avoiding trouble conditions In/out wiring terminals for 18 AWG to 12 AWG Mounts on 4" square or single gang USA electrical boxes. Adapter plate required for mounting on single gang electrical boxes. Optional wire guards Weatherproof back boxes are required for surface mounting. Figure 1: Indoor Ceiling Mount Strobe Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling code (NFPA 72), ANSI Al 17.1; the appropriate model bLilding code: BOcA, IcBo, or sBccl; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert Addressable Wiring Isolator Isolator Model 4905-9929 Isolator Model 4905-9929 is available for remote mounting on TrueAlert addressable circuits to isolate short circuited wiring from functioning wiring. Refer to data sheet S4905-0001 for additional information. TrueAlert ES Diagnostics Test Features Controllers can be selected to pulse each appliance's LED when it receives a supervision poll. When the controller is selected for diagnostic mode, the appliance magnet test feature provides a response at the individual appliance being tested. Silent Appliance Magnet Test The appliance LED pulses sequentially to conveniently indicate the apoliance's address when a magnet is applied. Operational Appliance Magnet Test In this test mode, after the address is indicated by pulsing the appliance LED, the strobe will briefly flash to indicate proper operation. TrueStart Instrument Two (TSIT) The 2nd generation of the Simplex True5tart Test Instrument adds testing of IDNAC SLc wiring and TrueAlert ES appliances to its ability to test lDcs, NAcs, and IDNet communications before connection to the control panel. Please contact your local Simplex representative for additional information. *Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. A49VO-0001 Rev. 12 3/2019 5SimpIEx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Installation Reference LH Address dip switch Set device address before fixing cover in place. Candela flag setting -.... Set flag to FACP to control candela rating from an FACP providing IDNAC notification. To set candela manually, set the flag to the desired candela rating. Wiring terminals for strobe connections accept #12-18 AWG wires Use slotted screwdriver here to remove cover IDNAC SLC Operation Advantage TrueAlert Addressable visible appliances on IDNAC SLCs TrueAlert Addressable visible appliances on IDNAC SLCs provide visible notification using one two-wire circuit that also confirms connection to the individual notification appliance's electronic circuit. This operation increases circuit supervision integrity by providing supervision that extends beyond the appliance wiring connections. Reduced current usage on IDNAC SLCs A constant 29 VDC source voltage is maintained, even during battery standby. This allows appliances to operate at higher voltage with lower current and ensuring a consistent current draw and voltage drop margin under both primary power and secondary battery standby. Efficiencies include wiring distances up to 2 to 3 times farther than with conventional notification, support for more appliances per IDNAC SLC, use of smaller gauge wiring, or combinations of these benefits. Reducing Installation and Testing Time With separate controls on the same two-wire SLC, installation time and expense for both retrofit and new construction can be significantly reduced. When Class B wiring is used, wiring can be T-tapped, allowing more savings in distance, wire, conduit (size and utilization), and overall installation efficiency. Use of the magnet test feature improves installation efficiency. TrueAlert device reports conveniently identify information about each connected appliance. Product Selection Table 1: Ceiling Mount Addressable Visual Only V/O Appliances Model* Lens color Description Installation Instructions 49VO-APPL. I 49 VO-AP PLC-BA Clear 49V0H-APPLC 1 49V0H-APPLC-BA VO appliance only. Select cover separately. 579-1227 49V0H-APPLCA Amber 49V0H-APPLCB - 1....1.••. 49V0H-APPLCG Green 579-1280 49V0H-APPLCR Red Table 2: Surface/WP back boxes Model lColor Installation instructions 49WPBB-VOCR Red 49WPBB-VOCW White rDscription ace/WP back box in red aceiwP back box in white 579-1270 Note: Use WP back boxes for surface mounting only. Using weatherproof back boxes does not make an appliance weatherproof. Page 2 AC49VOC-0001 Rev. 12 3/2019 5impIèx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 Table 3: Adapter plates Model Description Installation Instructions 49V0-APCS VO Ceiling Mount Adapter Plate. Required for 1 5791227 mounting on a single gang electrical box. Table 4: V/O Covers (Required when ordering APPLC models) Model* Color Wording 49V0C-CRALT Red ALERT 49V0C-CRBF FEU/FIRE - 49V0C-CRFEU FEU 49V0C-CRF FIRE 1Jo - )III/ALERT 49fp5 49V0C-CRBM 49V0C-CRBCF )l(/FIRE 49V0C-CRBAF j4,,>-/FIRE 49V0C-CK IBlack Blank 49V0C-CWALT White ALERT 49V0C-CWBF 49V0C-CWWEU FEU/FIRE FEU 49V0C-C\NF FIRE 49V0C-CWS 49V0C-CWBM Simplex logo only Jill/ALERT 49V0C-CWBCF T )/FIRE 49V0C-CWBAF j-/FlRE Table 5: Wire Guards Model - . . IDescription .. --. 49WG-VOCR VC) Ceiling Mount Red Wire Guard 49WGBB-VOCR JVO Ceiling Mount Wire Guard Back Box Note: * (-BA) indicates model is available either with or without the -BA suffix. Model numbers ending in -BA are assembled in the USA IDNAC SLC Controller Compatibility Reference Table 6: Compatibility Reference Compatible Controllers Data Sheet Controller Output IDNAC SIC Output Appliance Voltage Reference Voltage Design Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 29 VDC 23 VDC 4009 IDNAC Repeater P999 4100E5 Flex 35, 50, and 100 Amplifiers S4100-0034 IDNAC SLC (regulated) (with 6 VDC drop) 4100ES Constant Supervision and Signal Cards Page 3 AC49VOC-0001 Rev. 12 3/2019 !iSimplEx Visual Only Notification Appliances, Indoor Ceiling Mount Strobe, Model Series 49V0 TrueAlert ES V/O LEGACY Compatibility Reference Table 7: Compatibility Reference Compatible Controller Data Sheet Reference 'Controller Output Available Strobe lntenty Appliance Voltage Minimum 4100ES or4100U with 54100-0031 TrueAlert Power Supply TrueAlert Addressable SLC 15,30, 75, and 110 cd 17 VDC 4009 IFS, Remote TrueAlert 17 VDC Power Supply S4100-0037 TrueAlert Addressable S4009-0003 Controller (40091) Electrical Ratings Differences for Legacy Applications (refer to above specifications for other ratings) Voltage Range 117VDC to 31 VDC Special Application Candela Setting l5cd 130 cd 175cd 1110cd 17 VDC RMS Current Ratings, with horn on continuousat high setting, use when connected to 73 mA 114 mA 210 mA 1269 mA lrueAlertAddressable SLCs per above * For connection to legacy fire panel models Simplex 4009T and 4100,TPS. High candela (49V0H) appliances are not compatible with Simplex models 40091 and IFS, see the fire panel compatibility charts. Ceiling Mount V/0 Specifications Table 8: Specifications Specification Rating Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 1040 F (40° C) Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2 ); two Connections wires per terminal for in/out wiring, use unshielded Twisted Pair (UTP) for IDNAC. IDNAC SLC Loading Maximum of 127 addresses per SLC, 139 unit loads. See device and compatible Fire Panel Installation Instructions for circuit current load limits. Table 9: Percentage of rated light output at room temperature On-Axis Vertical, Below Axis Horizontal, Left/Rightof Axis Angle 0o 450 - 900 450 900 UL required output - 100% 45% 25% 45% 25% Typical output 327% 134% 83% 129% 47% Table 10: Appliance Specifications Specification Rating Operating Voltage Range 23 VDC to 30 VDC, Special Application Supervisory Requirements 1 unit load (= 0.8 mA control panel current) Flash Rate and Synchronized SLC 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, max 127 SN appliances per IDNAC Loading channel Candela 15 cd 30 cd 75 cd cd .110 cd .90/95 135 cd 185 cd Setting 49V0 model 55 mA 83 mA 153 mA N/A 199 mA N/A N/A Current 49V0H model N/A N/A N/A iN/A 1253 mA 296 mA 377 mA consumption** 49V0H amber N/A N/A N/A 1,253 mA (90 cd) 1296 mA 377 mA N/A lens 49V0H blue lens N/A N/A 253 mA 296 mA (95 cd) 377 mA N/A N/A ** Measured at 23VDC on IDNAC Addressable SLC © 2019 Johnson controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings may be applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). AC49VOC-0001 Rev. 12 3/2019 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0373 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexloo Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Model 49AVTrue Alert ES addressable horn/strobes with suffixes WRF, WRF-BA, MNF, WWF-BA, *wRS WRS-BA, WNS-BA, *WRQ WRQ-BA and APPLW. Model 49AVTrue Alert ES addressable horn/strobe covers with suffixes WRFIRE,WVVFIRE, WRS,\MNS, WRALT, WNALT, WRFEU, WtNFEU, WRBLNG, and \MNBLNG. Model 49VOTrue Alert ES addressable strobes with suffixes WRF, WRF-BA, VVVVF, \MNF-BA, *wRS WRS-BA, \Is MNS-BA, *WRA WRA-BA, *\A \MNA-BA, *\Q *WRQ ,WRQ-BA, and *Q Model 49VOCTrue Alert ES addressable strobe covers with suffixes WRFIRE, WNFIRE, WRS, WINS, WRALT, \MNALT, WRFEU, WNFEU, WRBLNG, and \MNBLNG. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 17-31 Vdc INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as a wall mount horn/strobe or strobe for indoor use only. Models require the use of the 4009-9401 TrueAlert NAC extender (CSFM Listing No. 7300-0026:214) or 4100-5120, -5121, -5122 True Alert Power Supples*or 4100-5311, -5313, -5325, 53-27 Extended Power Supplies (CSFM Listing No. 7165-0026:251) *or 4010-9601, -9602, -9603, -9604, -9606, 9701, -9702, 9722 Control Units (CSFM No. 7165-0026:369) or 4007-9201, -9202 Control Units (CSFM No. 7165-0026:378). Refer to listee's Installation Instruction Manual for details. *Rev 09-02-15 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct RV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTIL.LO, Program Coordinator Fire Engineering Division fi SimplEx TrueAlert Addressable Notification Appliances UL, ULC Listed; FM Approved* Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Introduction Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances are individually powered, addressed, and controlled from the Simplex Fire Alarm control Unit IDNAC Signaling Line circuit (SLC). Audio is supplied from a separate compatible Simplex Fire Alarm control Unit audio NAc. Wiring supervision is electronically monitored allowing audio and IDNAC wiring to be T-tapped for class B wiring, reducing wiring costs and wiring distances. Installation on standard 4 inch square 2 1/8 inch deep USA electrical boxes for flush installations (provided by others) or surface/WP backboxes (order below) for surface or WP installations. Appliances are available in 400-4000 Hz and 200- 10000 Hz high fidelity models. Separate appliance and cover selection greatly simplifies the ordering and installation process. Model numbers ending in -BA are assembled in the USA. Separate appliance and cover selection greatly simplifies the ordering and installation process. For more detailed information, please consult datasheet S49SWc-0001. Figure 1: Ceiling Mount Addressable Spea kerNisible Notification Appliance Ceiling Mount Addressable Speaker Product Selection Table 1: Ceiling Mount Addressable Speaker SN Appliances Model Description Installation - Instructions 495V-APPLc) SN appliance only. Select cover and surface/WP box (if 579-1203 495V-APPLC-BA required) separately. Table 2: High Fidelity Appliances Model iDescription Installation instructions High Fidelity SN appliance - 49HFV APPLC only. Select cover and 4gHFv-APpLc-BA surface/WP box (if required) 579-1203 separately. Table 3: High Candela Appliances Model Description Installation instructions High candela SN appliance 9 4 svH-AppLc-BA only. Select cover and 49SVH-APPLC jweatherproof box (if required) 579-1203 separately. Table 4: High Fidelity High Candela Appliances 1Description HFVH-APPLC - - ' SN Appliance Only. Select HFvH-AppLc-BA i cover and surfacetiNP box (if required) separately. 49HFVH-APLCA-BA Appliance with amber colored 5791203 lens. Select cover and surface/ IwP box (if required) separately. 'High Fidelity High candela S/ 49HFVH-APLCB-BA V Appliance with blue colored lens. Select cover and surface/ WP box _(if _required) _separately. Table 5: SN Covers (Required when ordering APPLC models) SKU 761or Wording 49Svc-cRALT lRed ALERT 49Svc-cwALT i,White 49Svc-cRBA Red j,-/FIRE 49Svc-cwBA iWhite 49Svc-cRBc iRed ALARM 495vc-cwac White /FlRE 49Svc-cRBF IRed 49Svc-cwBF White FEU/FIRE 49Svc-cRFEU Red FEU 49Svc-cwFEu 1White C-CFlRE R - ............................ --.- FIRE 49SvC-cwFlRE White 495VC-CRS IRed ....-- Si mplex logo only W.... - 495VC-CK Black No logo or lettering *Additional listings maybe applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. S49Svc-0001 Rev. 7 10/2018 Simplex Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Weatherproof Product Selection Table 6: Weatherproof Ceiling Mount Addressable SN Appliances SKU Description -- Installation instructions 46SVHAPPLC0 'SN Appliance Only. Select cover and surface/WP 5791241 49SvH-ApPLC-co (Canada only) box separately Table 7: SN Covers (Required when ordering APPLC-O models) SKU Color Wording 49SVC-CRALT-0 Red ALERT 49SVC-CWA LT- O White 49SVC-CRBA-O :Red 49SVC-CWBA-O —White 49SVC-CRBC-O Red */FIRE ALARM 49SVC-CWBC-0 White 4SSVC-CRBF-O Red 49SVC-CWBF-0 White :EU/FIRE 49SVC-CRFEU-O Red 'FEU 9S 4vC-CWFEu-O White 49SVC-CRFIRE-0 Red 49SVC-CWFIRE-O White FIRE 49SVC-CRS-0 Red 49SVC-CWS-0 White Simplex logo only 49SVC-CK-O Black Table 8: Surface/WP Back Boxes SKU lColor . - Description Installation instructions 49WPBB-SVCR Red Surface/WP back box in Red 5791240 49WPBB-SVCW White Surface/NP back box in White Table 9: Wire Guards and Wire Guard Back Boxes L Description t/GBB-SVCR-O Wire Guard Back Box, Ceiling, Red, WP AIG-SV4/CR Wire Guard, Ceiling, Red Ceiling Mount SN Specifications Table 10: Appliance General Specifications Specification Ràtihg Dimensions 8 1/8" H x 7 1/8"W x 3" D (206mm x 180mm x 76mm) Environmental 32° to 120° F (0° to 49° C); 10% to 93%, non-condensing at 104° F (40° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm to 3.31 mm2); two wires per terminal for in/out wiring. Use unshielded Twisted Pair (UTP) for IDNAC and audio wiring. Table 11: Speaker Audio Specifications ion Specifii - Ratng - ._--- i - Input voltage 25 or 70.7 Vrms Power Taps 1/4, ½, 1, and 2W Frequency Response 400 to 4000 Hz (SN, SNH), 200 to 10000 Hz (H/F, General Signaling = 125 to 12 kHz HFNH) Table 12: Speaker Output Ratings Wattage Tap 1/4 W ½ W 1 W 2W Model SN H/F SN H/F SN H/F S/V H/F Reverberant Chamber Test, per iiL148U(dBA) . 79 J76 83 0 186* ..Jgg* 87* Anechoic Chamber Test,_per_ULC-5541_(dBA)* 79 178 183 82 86* 85* 89* 88* * Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (peru554. -An ech.icChamber .Attenuat.Ofl- lAngle- 'Attenuation - Testing) Testing) -3 dB 170o '-6 dB 180, Page 2 S49SVC-0001 Rev. 7 10/2018 5 SimplEx Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Table 13: Percentage of rated light Angle On-Axis Vertical, Below Axis. Horizontal, Left/Right of Ails -- 45 450 190* UL required output 100% 45% [25% 45% 2500 Typical output 327% 134% 129% 47% Table 14: IDNAC SLC Specifications Specification i.Rating -. Typical Operating Voltage Range 23 VDC to 30 VDC, Special Application Appliance voltage design reference 23VDC (with 6VDC drop) Supervisory Requirements 1 unit load 0,8 mA control unit current) Flash Rate and Synchronized SLC Loading 1 Hz; with up to 63 synchronized strobes maximum per powered circuit, 127 SN appliances per IDNAC channel Maximum of 127 addresses per SLC, 139 unit loads. See device and IDNAC SLC Loading compatible Fire control Unit Installation Instructions for circuit current iload limits. unshielded twisted pair recommended IDNAC SLC Wiring Specifications (refer to control unit installation Maximum wire length allowed with 'T-Taps" for class B wiring per SLC = instructions for more information) 10000 ft (3048 m) I Maximum wire length to any appliance = 4000 ft (1219 m). This can be doubled to 8000ft (2438m) by using a 4009 IDNAC Repeater. Table 15: Current consumption** Candela Setting 115 cd 30 cd 75 cd 110 c 135 cd 185 cd 49SV and 49HFJ I159 mA models 82 mA 145 mA 1193mA N/A N/A 49SVH and 49HFVH N/A N/A N/A 1259 mA 281 mA 325 mA Weatherproof SV N/A N/A appliances _________ 320 mA 360 mA N/A - 400 mA ** Measured at 23VDC on IDNAC Addressable SLC Speakers are for connection to compatible fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. Table 16: Equipment Compatibility References Compatible Equipment Data Sheet Reference 4100ES with EPS+ or EPS Power Supply S4100-0100 4009 IDNAC Repeater S4009-0004 4100ES Flex 35 and 50 Watt Amplifiers 4100ES 100 Watt Amplifiers 'flS41OO-0034 4100ES constant Supervision and Signal cards Page 3 S49SVC-0001 Rev. 7 10/2018 Simplex Ceiling Mount Addressable Speaker Visible (SN) Notification Appliances Ceiling Mount SN Installation Reference Appliance with cover (front) -- Mount to 4"X4"X2-1/8" /Magnet test location electrical box using 8-32 indicated area that screws is not textured tO mount only 000,00000 0 Candela flag setting Set flag to FACP to control candela rating from an FACP providing notification I!J!MLl. and strobe connections accept F Wiring terminals for speaker •- ire 11=533HEMBEE-11 IIPJL im . Irme1I .1r I' . candela rating. Use slotted screwdriver 1ACP here to remove cover. the flag to the desired :'T~7~5 Figure 2: Installation reference © 2018j0hn50n controls. All rights reserved. All specifications and other information shown were current as of document revision and are subject to change without notice. Additional listings maybe applicable, contact your local Simplex® product supplier for the latest status. Listings and approvals under Simplex Time Recorder co. Simplex, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm code are registered trademarks of the National Fire Protection Association (NFPA). S49SV-0001 Rev. 7 10/2018 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:0384 Page 1 of 1 CATEGORY: 7125-- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Simplexl00 Simplex Drive, Westminster, MA 01441-0001 Contact: Jim Goyette (978) 731-8580 Fax (978) 731-8881 Email: james.goyette@jci.com DESIGN: Models: 495V-APPLC,49HFV-APPLC,49SV-APPLC-BA,49H FV-APPLC-BA,49SVH-APPLC-BA, 49HFVH-APPLC-BA,49SVH-APPLC,49HFVH-APPLC,495V-CWF,49HFV-CWF,49SVH-CW F and 49HFVH-CWS True Alert ES, Addressable ceiling mounted Speaker/Strobes. Models: 495V-APPLW,49HFV-APPLW,495V-APPLW-BA,49HFV-APPLW-BA,495V-WRF, 49HFV-WRF, *49SvAppLWo *49SVAPPLW0BA *49SVAPPLWCO True Alert ES, Addressable wall mounted Speaker/Strobes. Refer to listee's data sheet for detailed product description and operational consideration. RATING: 23-30 Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as signaling devices for the hearing impaired when used with listee's separately listed electrically compatible fire alarm control units. For indoor and outdoor use. Refer to listee's Installation Instruction Manual for details. *Revision 04-17-2018 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2019 Listing Expires June 30, 2020 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division johnson Controls Johnson Controls Fire Protection, LP, 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com Contractor's License Detail for License # 986047 I Business Information JOHNSON CONTROLS FIRE PROTECTION LP P 0 BOX 3042 BOCA RATON, FL 33431 Business Phone Number:(562) 405-3800 Entity Partnership Issue Date 08/14/2013 Expire Date 08/31/2021 This license is current and active. All information below should be reviewed. Classifications C10 - ELECTRICAL C16 - FIRE PROTECTION CONTRACTOR Bonding Information Contractor's Bond_ This license filed a Contractor's Bond with FEDERAL INSURANCE COMPANY. Bond Number: 82332032 Bond Amount: $15,000 Effective Date: 01/01/2016 Contractor's Bond History Elill________ ______ Bond of Quahfying tndivicival This license filed Bond of Qualifying Individual number 82332031 for RONALD GILBERT MAYLE in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 08/13/2013 This license filed Bond of Qualifying Individual number 82520648 for JOSEPH ANTHONY FEDDELER in the amount of $12,500 with FEDERAL INSURANCE COMPANY. Effective Date: 07/26/20180 Workers' Compensation This license has workers compensation insurance with the OLD REPUBLIC INSURANCE COMPANY Policy Number:MWC313943 Effective Date: 10/01/2018 Expire Date: 10/01/2020 Workers' Compensation History Other -- - Personnel listed on this license (current or disassociated) are listed on other licenses. 10/11/2019 REV.#: 0 PROJECT #: 480- Johnson Controls Johnson Controls Fire Protection, LP 3568 Ruffin Road, South San Diego, CA 92123-2597 Tele: (858) 633-9100 Fax: (858) 633-9101 www.JohnsonControls.com 10/11/2019 REV.#: 0 PROJECT #: 480-