Loading...
HomeMy WebLinkAbout5780 FLEET ST; ; FPC2018-0060; Permitty PERMIT REPORT Ur-isb ö of ad Print Date: 02/04/2022 Permit No: FPC2018-0060 Job Address: 5780 FLEET ST, CARLSBAD, CA 92008-4702 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: Track #: Applied: 02/20/2018 Valuation: $0.00 Lot #: Issued: 03/05/2018 Occupancy Group: Project #: Finaled Close Out: 08/19/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: PACIFIC RIDGE CORPORATE CENTER -FIRE RECALL SYSTEM FOR ELEVATOR MOD Applicant: FPContractor: NOVA SECURITY NOVA SECURITY CORY HILL 8779 COTTONWOOD AVE, # STE 103 358 RIVER TRAIL PL SANTEE, CA 92071457 SANTEE, CA 92071-6907 (619) 448-3007 (619) 448-3007 FEE AMOUNT FIRE TI Fire Alarm System $601.00 Total Fees: $601.00 Total Payments To Date: $601.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov PACIFIC RIDGE CORPORATE CENTER 5790 FLEET STREET CARLSBAD, CA 92008 Fire Alarm Submittal 02/16/18 FPC20180060 5780 Fleet ST F NEW& ~ lKh .FILE COPY Submitted By; N+--:V^—SERIY 8779 Cottonwood Avenue SUITE 103 Santee, CA. 92071 619-448-3007 Cont. Lie. C-10 # 802053 PACIFIC RIDGE CORPORATE CENTER Qty Description 1 Fire Alarm Panel 4 Smoke Detector 2 Addressable Relays Fire Alarm Submittal Equipment List Model Manufacture CSFM# IPA-60 POTTER 7165-0328:500 PAD 100 PD POTTER 7272-0328:504 PAD100-RM POTTER 7165-0328:500 (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel Features 60 addresses available on this analog addressable system Additional system capacity achieved via multi-point SLC modules 99 software zones NFPA 72 Compliant Smoke Sensitivity Test Built-In System Operates as Class A or Class B for SLC, P-Link and NACs 5 Amp Power Supply, Expandable to 310 amps 2 NACS, Regulated, Rated at 3 Amps each, expandable to 188 2 Input/Output (I/O) Circuits for system flexibility rated at 1 Amp each, ideal for manual release and abort Strobe Synchronization and System Wide Sync for Potter/AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes Dedicated Alarm, Supervisory and Trouble Relays 4,000 Event History Buffer Cabinet will house up to 18 A batteries Optional two line DACT with UD-1000 that can report General, Zone or Point Information Built in TP Communicator Ethernet Port for Programming and Network Connectivity E-Mail System Status, Reports and Event Information Product includes 5 year warranty. LISTED UUKL Compliance accomplished when using DRy-SO with the Space Age Electronics GL8 Description Technical Specifications The IPA-60 is an analog/addressable releasing fire alarm system with a total system capacity of 60 addresses. Additional capacity on the system is achieved using multi-point SLC modules. The control panel utilizes the exclusive Potter protocol that includes a complete line of sensors and modules. Each SLC may be comprised of any combination of smoke sensor, heat detectors or modules and allows for a total of 50 ohms of impedance and may use any wire compliant with the National Electrical Code (NEC). The IPA-60 has a 5 Amp power supply with two Notification Appliance Circuits (NACs) and two Input/Output (I/O) circuits. The NACs are rated at 3 Amps each and the I/Os are rated at I Amp each. Each output is regulated and power limited. In addition, each output is uniquely programmable and may be configured for steady signal, strobe synchronization, constant power, door holder power, or releasing. The strobe synchronization includes Potter/AMSECO, Gentex, System Sensor and Cooper/Wheelock and with the exclusive Quadrasync each output may have a unique brand and all strobes will flash together. The I/Os are designed for inputs such as manual release stations and abort switches that will not require polling and react nearly instantaneously. The IPA-60 is listed for releasing of fire suppression systems. The software allows cross zones, counting zones, and timers for suppression. The system is capable of multiple release outputs across multiple hazards. In addition, the PSN-1000 may be used to extend releasing capability. The NACs may be expanded using the PSN-1000 series intelligent power supplies. Each PSN-I 000 adds another 10 Amps of power, 2 additional input circuits and the IPA-60 will support up to 31 power supplies. The system will synchronize the strobes system wide. In addition, the PSN- I 000E has space to allow the installation of up to six expansion cards. The cards mount on a stacker bracket that allows access to all SLC circuit connections. Dimensions 16"W x 17"H x 3 718"D 3.0 Amps @ 120 VAC 50/60 HZ AC Mains 2.0 Amps @ 240 VAC 50/60 HZ Enclosure 16 gauge cold rolled steel with removable locked door with Lexan viewing window Standby Current-130 mA Alarm Current-200 mA 5 Amps power for NACs, I/O, and P-Link Battery 3 Amps per NAC, regulated 1 Amp per I/O circuit, regulated Battery Charger range 8-55 Ah Battery Charger voltage 27.3 VDC P-Link maximum current of 1 Amp Temperature and 32° to 120° (0°C to 49°C) with a maximum Humidity Range humidity of 93% non-condensing. NFPA 12, 12A, 13, 15, 16, 17, 17A, 70, 72, 750, and 2001 ANSI/UL 864 - Local (L), Remote Sta- tion (RS), Central Station (CS), Propriety (PPU), Auxiliary (AUX).Type of Service: Automatic (A), Manual (M) Water flow Standards (WF) Sprinkler Supervisory (SS) Type of Signaling: Digital Alarm Communicator (DAC), March Time (March), Non Coded (NC), Reverse Polarity (Rev Pol), Other Technologies (OT) IBC 2000, 2003, 2006, 2009, 2012 Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830100-REVB • 05/17 PAGE 1 0F4 (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel SLC Loop Accessories The control panel may be connected with up to 60 addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PAD 00-PD Analog Photo Electric Smoke Detector is a smoke detector with a listed obscuration of 1.02 to 3.83 percent per foot. PADI00 PHD Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector. PAD 100-HD Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F. PAD 100-DUCTR Addressable Duct Smoke Detector with Form C Relay. PAD 100-DUCT Addressable Duct Smoke Detector. PAD 100-6B 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. PAD 100.4B 4" round base that may be mounted to an electrical box and wired for connection to the above sensors. PAD! 00-TB Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. PAD 100-RB Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. PAD100-SB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. PAD 100-CD Addressable CO gas detector. PAD 100-DD Addressable photo electric smoke detector for use in DUCT/DUCTR enclosure. Modules Device Description PAD 100-MIM Micro Input Module provides a small foot print contact module for mounting inside an enclosure. PADI 00-PSSA Single Action Addressable Pull Station. PADI 00-PSDA Dual Action Addressable Pull Station. PAD 100-SIM Single Input Module is a standard contact module with an LED that mounts into a 4" square electrical box. PAD 100-DIM Dual Input Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. PAD I 00-TRTI Two Relay Two Input module provides two form C relays that are individually controlled by the control panel. Each relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. Also provides two contact inputs. PADTOO-NAC Notification Appliance Circuit module is an addressable remote appliance circuit controlled by the panel. PAD100-ZM Zone Module is used to connect conventional 2-wire smoke detectors to the system. PAD100-IM Isolater Module interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. PADlOO-RM Relay Module that provides one form C relay controlled by the control panel. Relay is rated for 2 amps at 30VDC or 0.5 amps at 125VAC. PAD 100-LED Module provides a single addressable LED that is controlled by the control panel. PAD1 00-SM Speaker Module provides switching for two audio channels. PAD100-LEDK Addressable LED and key switch that mounts in a single gang box. PAD 100-DRTS DUCTR Remote Test Switch that mounts n a single gang box and optionally supervised. PAD100-OROI One Relay One Input Module provides one form C relay and one input. The relay is rated at 2 amps at 30VDC or 0.5 amps at 125VAC. Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830100-REVB • 05/17 PAGE 2OF4 ® POTTER The Symbol of Protection IPA-60 Fire Alarm Control Panel SLC Features The Potter protocol is a digital protocol with a proven design for reliability and noise immunity. The system does not require special cable or conductors for connection of the Signaling Line Circuit as long as the cable is compliant with NFPA 70 and NFPA 72. The system allows for Class A or Class B installations as well as "T-Taps", with a max wiring distance of 10,000 Ft. Sensor Features The sensors through the fire alarm control panel provide a real time status as to the condition of the system. The smoke detector sensitivity, heat detector temperature level and drift compensation are all programmable options. The system also allows for a day/night mode where the panel automatically adjusts the sensitivity depending on the time of day. To assist in the reduction of false alarms, the smoke detectors also have a maintenance warning that sends a trouble signal when a detector is dirty to the point that it can no longer maintain the programmed sensitivity. User Interface The fire alarm control panel has a 2 x 16 LCD display to provide information to the system status. The keypad has navigation keys to allow manipulation of the Menu on board the panel. The panel is shipped standard with the following LEDs: AC Power - Green Alarm - Red Earth Fault - Amber Supervisory - Amber Silenced - Amber Trouble - Amber Pre-Release - Amber Release - Red The common buttons include a Silence, Reset, Acknowledge, and Drill. All of the buttons are accessible once the locked door is opened. P-Link The IPA-60 has a proprietary communication protocol that communicates through a RS-485 connection to field devices. Up to 64 devices may be connected to a single P-Link connection. The P-Link includes the communication terminals and regulated 24 VDC connection for the field devices. The field devices may be any of the following: PAD IOO-SLCE-Analog/Addressable loop expansion module RA-6075R —2 x 16 LCD annunciator with a key pad in a locked metal enclosure. RA-6500R(F) —4 x 40 LCD annunciator with a key pad in a locked metal enclosure. Flush mount version available. LED-16(F) - 16 LED annunciator with common indicators in a locked metal enclosure. Flush mount version available. PSN-1000(E) - 10 amp, remote intelligent power supply with 6 NACs, 2 I/Os and a P-Link repeater. This panel is listed in conjunction with the IPA-60 as releasing circuits. CA-6500 - Class A convertor that converts the SLC, NACs and P-Link connection UD-1000 —UL listed, Dual line telephone alarm communicator DRV-50 - LED driver expander, used to connect up to 50 LEDs in a graphic display FCB-1000 - Fire communication bridge, provides remote mounting of the Ethernet connection FIB-1000 - Fiber interface module, used to extend P-Link to multi- mode fiber (2 required) RLY-5 - Relay module, provides 5 form C relay contacts rated at 3.0 amps 24VDC/125AC SPG-1000 - Serial parallel gateway, allows for the connection to a serial or parallel printer The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the stacker bracket or ordered with the optional rack mount enclosure. MC-1000 Multi-Connect allows up to sixty-three IPA series panels to share a single reporting technology. AE-2 - Two card expansion cabinet AE-8 - Eight card expansion cabinet AE-14 - Fourteen card expansion cabinet Ethernet/I.P. Connection The IPA-60 is shipped standard with an Ethernet connection. This connection is the programming port and may be connected to a building Wide Area Network (WAN) or Local Area Network (LAN). Once connected to the Internet, the panel may be selectively programmed to e-mail alarm conditions, trouble conditions, supervisory conditions, test, Event History and detector status. An e-mail may be sent to the panel and the panel will e-mail the event history, detector status, configuration file or server status to an authorized E-mail account. In addition, reminders may be set to send an e-mail for service, testing or other conditions. In addition, the Ethernet connection is UL listed as an IP communicator. The IP communicator is listed to report to the UL listed Sur-Gard III IP receiver. The IP communicator replaces the traditional less reliable alarm communicator transmitter that utilized telephone lines. The IP communicator is an active method of connection and communication to the monitoring station. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com 8830100-REVB • 05/17 PAGE 3OF4 (E)POTTER IPA-60 The Symbol of Protection Fire Alarm Control Panel Dimensions 0 01 TOP • DEPTH =3.75' oj DOOR = 16.07' BACKBOX = 15.77 DEPTH = 3.84" 0 "0 LEFT SIDE o BOTTOM RIGHT SIDE DWG #593-1 Ordering Information Model Description I Stock No. IPA-60 Fire Alarm Releasing Control Panel 13992714 Compatible Releasing Devices Note: For releasing applications please order the Potter EOLD (3005012) for circuits connected to a releasing solenoid or actuator. Brand Description Skinner 73218BN4UNLVN0C112CZ 732 12BN4TNLVNOC322C2 Victaulic 753-E Series Mini Max MX 123 & MX200 wl 8876677 & 889323 Viking 11591, 11601, 11602, 13843, & 13844 TLX PA0036 Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 . www.pottersignal.com 8830100-REVB • 05/17 PAGE 4OF4 (E.)POTTER The Symbol of Protection Features PAD 00-RM Relay Module One (I) Form C relay contact SLC Class A, Class X & Class B Mounts in a standard 4" or double gang box Wiring terminals accessible when mounted in box All wiring terminals accept 22 to 12AWG Product includes a 5 year warranty 13 Description The PAD 100-RM uses one (1) SLC loop address to provide one (1) Form C relay contact. The module mounts on either a 4" square or double gang box. The PAD 100-RM includes one red LED to indicate the module's status. In normal condition, the LED flashes when the device is being polled by the control panel. Application The PAD IOO-RM is compatible with Potter's IPA series addressable fire alarm control panels. The PAD100-RM is an interface module providing one (I) Form C relay contact. Setting the Address Each addressable SLC device must be assigned an address. The address is set using the DIP switch located on the PAD IOO-RM. The PAD 100-RM uses a single device address to identify relay contacts. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to the panel or device: Power to the device is removed. Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24.0V Max SLC Standby 240iA Current Max SLC Alarm Current 2401A Relay Contacts 2A @3OVDC, 0.5A @125VAC Operating Temperature Range 32 to 120°F (0 to 49°C) Operating Humidity Range 0 to 93% (non-condensing) Max no. of Module Per 127 units Loop Dimensions 4.17" (106mm)L x 4.17" (lO6mm)W x 1.14" (29mm)D Mounting Options Standard 4" Square or Double Gang Box Shipping Weight 0.6 lbs Potter Electric Signal Company, LLC • St. Louis, MO Phone: 800-325-3936 www.pottersignal.com 8830084 -REV B • 12/17 PAGE 1 OF 2 (E)POTTER The Symbol of Protection PAD 00-RM Relay Module Installation Using Compatible Electrical Box Fig 1 Wiring Diagram PADIOO-RM Relay Circuit Fig 2 FROM FACP OR PREVIOUS MODULE TO NEXT MODULE 0D o VD I LM 1) FORM C E—R'~c TF: RELAY CONTACTS 0 LIJ o a a 0 0 c o cD It is possible that the internal relay in the PAD I 00-RM may be shipped in the non-normal I activated state. To ensure that the internal relay is set to the normal state, connect the module to the SLC loon and reset the control nanel before terminating the wiring to the modules output. Ordering Information Model Description I Stock No. PADIOO-RM Relay Module 1 3992705 Potter Electric Signal Company, LLC St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830084-REVB • 12/17 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION MPAI—S OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0328:0500' Page 1 of 1' CATEGORY:' 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: bilIwpottersignal.com DESIGN: Models IPA-60, IPA-100, and IPA-4000 fire alarm control units. Automatic, Manual, waterflow and sprinkler supervisory type device and local, auxiliary, releasing, remote station (PPU), proprietary (PPU) and central station (PPU) services. Refer to listee's Installation Instruction Manual for details. System components (CSFM Listing 7305-0328:0200): PAD100-DIM Dual Input Module PAD100-LED Addressable LED Module PAD 100-OROI One Relay-One Input Module PAD 100-RM Relay Module PAD 100-SIM Single Input Module PAD 100 TRTI Two Relay-Two Input Module PAD 100-ZM Zone Module PAD 100-IM lolator Module PAD 100- NAC Notification Appliance Circuit Module PAD 100-SM Speaker Module PAD 100-MIM Micro Input Module PAD 100-LEDK LED Key Switch Module PAD 100-DRTS Duct Remote Test Switch PAD 100-SLCE127 Point SLC Expander MC-1000 Multi-Connect PAD 100-DUCTR AE-2 Enclosure RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, rating and UL label. APPROVAL: Listed as fire alarm control units when use with separately listed electrically and functionally compatible initiating and indicating devices. Refer to listee's Installation Instruction Manual for details. 03-07-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2017 'Listing Expires) June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division (E)POTTER PAD100-PD The Symbol of Protection Photoelectric Smoke Sensor Features Low profile, less than 2 inches with the base Wide selectable sensitivity range of 1.0 to 3.70/o/foot Sensor communicates sensitivity to control panel UL listed smoke calibration and sensitivity Optional locking tab to prevent unwanted removal Simple DIP switch address setting, no programming tool required LED alarm indicator Product includes a 5 year warranty X@ LISTED Description The Photoelectric Smoke Sensor is a listed Analog Addressable smoke sensor compatible with fire alarm control panels that utilize the Potter Addressable Device (PAD) protocol. The PAD 100-PD is a low profile smoke sensor with a wide sensitivity range. The sensor and base (not included) are made of a durable plastic in an off-white color to blend in with the ceiling. The PAD 100-PD has a sensitivity range of 1.0 to 3.7 % per foot and is UL. The PAD100-PD features drift compensation and has built in dirty detector warning as well as. The PAD 100-PD and the control panel communicate over a proven and robust digital communication path and the system analyzes the information at the particular device. The total polling speed is less than five (5) seconds, well under the UL requirements. The sensor is compatible with any of the PAD series sensor bases and simply twists on. The PAD100-PD is addressed using DIP switches in the rear of the sensor and can be easily programmed in the field without special tools. Setting the Address Each addressable device on the SLC loop must have a unique address from 1 to 127 to function properly. The address is set using DIP switches. Before connecting a device to the SLC loop, take the following precautions to prevent potential damage to SLC or device. Verify the following: Power to the device is removed Field wiring is correctly installed. Field wiring has no open or short circuits. Technical Specifications Operating Voltage 24 VDC Detector Current Draw 300 tA Alarm indicator 1 LED Alarm set-point range 1.0 to 3.7 %/ft 3.6-12 %/m Installation temperature 32 to 120 0 F / 0 to 49 ° C range Operating relative 0% to 93% (Non-condensing) humidity range Start-up time Max. I sec. Maximum number of 127 addresses per loop Maximum number of lighted indicators in 30 alarm per loop. Color Eggshell White Weight (without base) I01g (3.56oz) Dimensions (without Height: 1.35 in (34mm) base) Diameter: 3.93 in (100 mm) Wall Mount 12" max. from ceiling Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 www.pottersignal.com 8830108- REV B • 12/17 PAGE 0F2 ® P011ER The Symbol of Protection 'PADI 00-PD Photoelectric Smoke Sensor Air Velocity Ratings The PAD 100-PD has an Open Area of Protection air velocity rating of 0 to 300 feet per minute. The system has a maximum of 30 LEDs that can be turned on simultaneously. If the system already has 30 LEDs on, the PAD 100-PD will operate even though the LED may not illuminate. Operation The PAD IOO-PD is an analog addressable sensor that uses one address on the Signaling Line Circuit (SLC) of a compatible fire alarm control panel. The unit communicates with the control panel as it is polled. The LEDs flash every time the unit is polled and they will flash at a fast rate if the unit is in an active status. The polling LED can be turned off if desired for less conspicuous operation. The PAD] 00-PD with the PAD 100-4DB or PAD100-6DB has a low profile of less than two (2) inches to blend into the surrounding environment. The sensor includes an insect screen to prevent foreign objects from reaching the chamber and the can be cleaned to restore operation of a dirty detector. Sensor Sensitivity The PAD 100-PD and the compatible control panel work in tandem to keep the sensitivity consistent. As the sensor is installed over time, the sensor compensates for the dirt in the unit until it is out of range. At that time, the panel will indicate a dirty sensor. The sensor will then have to be cleaned or replaced. The PAD 100-PD can be programmed to provide a maintenance alert prior to reaching the dirty sensor level which will allow for intervention prior to the sensor going into trouble. This allows for sensor replacement or cleaning prior to a nuisance trouble occurs. NOTE: As required by NFPA, do not install the sensors until all construction is complete and the work area has been thoroughly cleaned. If the sensors have been installed in a construction environment, they should be cleaned or replaced before the system is placed into service. Spacing/Mounting The PAD 100-PD is UL listed with a recommended maximum spacing of 30 feet. Refer to NFPA 72 for specific information regarding detector spacing, mounting location, and special applications. Compatible Bases All bases will mount on a single gang, double gang, octagon, 4" square or mud ring electrical box. Device Description Stock No. PAD 100-4DB 4" Standard Base 3992731 PAD 100-6DB 6" Standard Base 3992732 PAD 100-lB 6" base with an isolator module included. 3992730 PAD 100-RB 6" base with one Form-C relay contact. 2A @ 30VDC, 0.5A @ 125VAC 13992728 PAD 100-SB 6" base with sounder module included. Sound pattern is provided from external source. 3992729 Ordering Information Model Description I Stock No. PADIOO-PD Photoelectric Smoke Sensor 3992733 Potter Electric Signal Company, LLC . St. Louis, MO Phone: 800-325-3936 . www.pottersignal.com 8830108- REV B • 12/17 PAGE 2OF2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING . BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0328:0504 Page 1 of I CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: billw@pottersignal.com DESIGN: Models PADIOO-PD, PADICO-DD and PAD100-PHD photoelectric smoke detector heads. Model PAD1 00-PHD has an intergral heat detector. Refer to Listee's data sheet for detailed product description and operational considerations. RATING: 24Vdc INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Models PAD100-PD' and PADIOO-PHD are listed as photoelectric smoke detector heads for use with listee's detector base Models PAD100-4DB, PAD100-6DB, PADIOO-RB, PADI 00-SB (CSFM#7300-0328:502) and Model PAD 100-I B (CSFM#7300-0328:501). Model PAD100-DD is listed as a photoelectric smoke detector head for use with Model PAD 00-DUCT (CSFM#3248-0328:0505). Refer to listee's Installation Instruction Manual for details. 06-21-2017 dcc To This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 07, 2017 Listing Expires \June 30, 2018 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division