Loading...
HomeMy WebLinkAbout6200 FLYING LEO CARRILLO LN; ; FPC2019-0018; Permit1City of PERMIT REPORT Carlsbad Print Date: 02/04/2022 Job Address: 6200 FLYING LEO CARRILLO IN, CARLSBAD, CA 92009-3042 Permit Type: FIRE-Construction Commercial Work Class: Fire Alarm Parcel #: 2226010400 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPC2019-0018 Status: Closed - Finaled Applied: 02/05/2019 Issued: 02/22/2019 Finaled Close Out: 08/19/2021 Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: LEO CARRILLO RANCH STABLE -FIRE ALARM NOTIFICATION AND DETECTION IN BARN AREA Applicant: FPçontractor: COSCO FIRE PROTECTION INC COSCO FIRE PROTECTION INC JOHN MOCKER 1075 W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE TI Fire Alarm System $620.00 Total Fees: $620.00 Total Payments To Date: $620.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 f I www.carlsbadca.gov 5/ DN-7070:P • A-b N FS2-3030 Intelligent Addressable Fire Alarm System General The NFS2-3030 is an intelligent Fire Alarm Control Panel (FACP) designed for medium- to large-scale facilities. Fire emergency detection and evacuation are extremely critical to life safety, and the NFS2-3030 is ideally suited for these appli- cations. The NFS2-3030 is part of the ONYX® Series of prod- ucts from NOTIFIER. The NFS2-3030 is ideal for virtually any application because it features a modular design that is config- ured per project requirements. With one to ten Signaling Line Circuits (SLCs), the NFS2-3030 supports up to 3,180 intelli- gent addressable devices. Information is critical to fire evacuation personnel, and the NFS2-3030's large 640-character Liquid Crystal Display (LCD) presents vital information to operators concerning a fire situa- tion, fire progression, and evacuation details. A host of other options are available, including single- or multi- channel voice; firefighter's telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection prod- ucts for challenging environments; wireless fire protection; and many additional options. Features Certified for seismic applications when used with the appro- priate seismic mounting kit. Approved for Marine applications when a marine-listed ver- sion is used with marine-listed compatible equipment. See DN-60688. Complies with UL 2572 Mass Notification Systems (NFS2- 3030 version 20 or higher). One to ten isolated intelligent Signaling Line Circuits (SLC) Style 4, 6 or 7. Wireless fire protection using SWIFT Smart Wireless Inte- grated Fire Technology. See DN-60820. Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. - Detectors can be any mix of ion, photo, thermal, or multi- sensor; wireless detectors are available for use with the FWSG. - Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG. Large 16 line, 640 character LCD backlit display or use display-less as a network node. Network options: - High-speed network for up to 200 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). —Standard network for up to 103 nodes (NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/400, AFP-1010, and AM2020). Up to 54 nodes when DVC-EM is used in network paging. Built-in Alarm, Trouble, Security, and Supervisory relays. VeriFire® Tools online/off ine program option. NOTIFIER® by Honeywell NFS2-3030 (left) and NFS2-3030 with DVC audio option (right) With built-in Degraded Mode operation, the system is capa- ble of general alarm if a fire alarm condition is present even if the central processing unit (CPU) fails. Weekly Occupancy Schedules allow changing sensitivity by time of day and day of week. EIA-485 annunciators, including custom graphics. History file with 4000-event capacity in nonvolatile memory, plus separate 1000-event alarm-only file. Advanced history filters allow sorting by event, time, date, or address. Alarm Verification selection per point, with automatic counter. Autoprogramming and Walk Test reports. Multiple central station communication options: - Standard UDACT - Internet - Internet/GSM Positive Alarm Sequence (PAS) Presignal. Silence Inhibit and Auto Silence timer options. Field-programmable on panel or on PC, with VeriFire Tools program, also check, compare. Non-alarm points for lower priority functions. Remote ACKJSignal Silence/System Reset/Drill via monitor modules. Up to 1000 powerful Boolean logic equations. Supports SCS Series smoke control system in both HVAC and FSCS modes. FM6320 approved Gas Detection System with FMM-4-20 module and any FM listed gas detector. EIA-232 printer port. EIA-485 annunciator port. DN-7070:P • 3/8/17 - Page 1 of 8 111111,u iIi!1Pllffl E S o 640-CHARACTER DISPLAY FEATURES Backlit, 640-character display. Program keypad: full QWERTY keypad. Up to nine users, each with a password and selectable access levels. 11 LED indicators: Power; Fire Alarm; Pre-Alarm; Secu- rity; Supervisory; System Trouble; Other Event; Signals Silenced; Point Disabled; CPU Failure; Controls Active. Membrane Switch Controls: Acknowledge; Signal Silence; Drill; System Reset; Lamp Test. LCD Display: 640 characters (16 lines x 40 characters) with long-life LED backlight. FLASHSCAIP INTELLIGENT FEATURES Polls up to 318 devices on each loop in less than two seconds. Activates up to 159 outputs in less than five seconds. Multicolor LEDs blink device address during Walk Test. Fully digital, high-precision protocol (U.S. Patent 5,539,389). Manual sensitivity adjustment - up to nine levels. Pre-alarm ONYX intelligent sensing - up to nine levels. Sensitivity levels: - Ion —0.5 to 2.5%/foot obscuration. - Photo - 0.5 to 2.35%/foot obscuration. - Laser (VIEW®) - 0.02 to 2.0%/foot obscuration. - Acclimate PlusTM —0.5 to 4.0%/foot obscuration. - IntelliQuad - 1.0 to 4.0%/foot obscuration. - lntelliQuadTM PLUS - 1.0 to 4.0%/foot obscuration Drift compensation (U.S. Patent 5,764,142). Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515). Automatic detector sensitivity testing (NFPA-72 compliant). Maintenance alert (two levels). Self-optimizing pre-alarm. Programmable activation of sounder/relay bases during alarm or pre-alarm. Read Status displays the level of detector cleanliness. FSL-751 VIE W@ (VERY INTELLIGENT EARLY WARNING) SMOKE DETECTION TECHNOLOGY Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524). Addressable operation pinpoints the fire location. Early warning performance comparable to the best aspira- tion systems at a fraction of the lifetime cost. Sample System Options SLC Intelligent Loop DEWCES R ---------- I J Upto32 LCD-160 LCD2-80 remote displays EIA-485 - ll FWSG FAPT-851 NBG-12LX T 4 XP6110 I/O Modules FSL-751 FSP-851 FMM-1 FRM-1 FSAB000 etc. IDC Relay Contact CPU2-3030D display or CPU2-3030ND EIA-485 3072 annunciator/control points 4 ACM-8R ACM/AEM-24AT LDM-32 Relay Control LED Annunciator Custom Graphics Dual phone lines to Optional 2048-point UDACT Central Station ElA-232 NFS2-3030 IHIIII Shown in CAB-C4 with display DVC-EM audio in CA-1 in second tier PRN Series Printer NOTE: CPU2-3030 firmware version 14.0 (and higher) can support LCD-160 on the RDP port, or LCD2-80 in terminal mode, but not both at the same time. Page 2 of 8— DN-7070:P • 3/8/17 FAPT-851 ACCLIMATE PLUS TM Low-PROFILE INTELLIGENT MULTI-SENSOR Detector automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. Microprocessor-based technology; combination photo and thermal technology. Low-temperature signal at 40°F ± 5°F (4.44°C ± 2.77C). FSC-851 INTELLIQUAD ADVANCED MULTI-CRITERIA DETECTOR Detects all four major elements of a fire (smoke, heat, CO, and flame). Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. INTELLIGENT FAAS70 DETECTORS FSA-5000, FSA -8000, FSA- 20000 AND FSA-20000P Connects directly to the SLC loop of compatible ONYX series panels. Provides five event thresholds that can be individually pro- grammed with descriptive labels for control-by-event pro- gramming; uses five detector addresses. Uses patented particle separator and field-replaceable filter to remove contaminants. Advanced algorithms reject common nuisance conditions FSA-5000 covers 5,000 square feet through one pipe. FSA-8000 covers 8,000 square feet through one pipe. FSA-20000 covers 28,800 square feet through one to four pipes. FSA-20000P covers 28,800 square feet through one to four addressable pipes. Supports addressable pipes to pinpoint location of alarm events. FCO-851 INTELLIQUADTM PLUS ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR Detects all four major elements of a fire. Separate signal for life-safety CO detection. Optional addressable sounder base for Temp-3 (fire) or Temp-4(CO) tone. Automatic drift compensation of smoke sensor and CO cell. High nuisance-alarm immunity. FMM-4-20 GAS DETECTION MODULE Interface to industry-standard linear scale 4-20 mA sensors. Five programmable thresholds. FM Approved, Class 6320 (Stationary Gas Sensors! Detectors). SWIFT WIRELESS Self-healing mesh wireless protocol. Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices. Up to 4 wireless gateways can be installed with overlapping network coverage. RELEASING FEATURES Ten independent hazards. Sophisticated cross-zone (three options). Delay timer and Discharge timers (adjustable). Abort (four options). VOICE AND TELEPHONE FEATURES Up to eight channels of digital audio. 35 watt, 50 watt, 75 watt, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series). Solid state message generation. Hard-wired voice control module options. Firefighter telephone option. 30- to 120-watt analog amplifiers (AA Series). Backup tone generator and amplifier option. FlashScan® Exclusive World-Leading Detector Protocol At the heart of the NFS2-3030 is a set of detection devices and device protocol - FlashScan (U.S. Patent 5,539,389). FlashS- can is an all-digital protocol that gives superior precision and high noise immunity. As well as giving quick identification of an active input device, this protocol can also activate many output devices in a frac- tion of the time required by competitive protocols. This high speed also allows the NFS2-3030 to have the largest device per loop capacity in the industry - 318 points - yet every input and output device is sampled in less than two seconds. The microprocessor-based FlashScan® detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test. ONYX Intelligent Sensing ONYX Intelligent Sensing is a set of software algorithms that provide the NFS2-3030 with industry-leading smoke detection capability. These complex algorithms require many calcula- tions on each reading of each detector, and are made possible by the very high-speed microcomputer used by the NFS2- 3030. Drift Compensation and Smoothing. Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces maintenance requirements by allowing the system to automatically perform the periodic sensitivity measurements required by NFPA 72. Smoothing filters are also provided by software to remove transient noise signals, usually caused by electrical interference. Maintenance Warnings. When the drift compensation per- formed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given. There are three warning levels: (1) Low Chamber value; (2) Maintenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit. Sensitivity Adjust. Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change automatically between day and night. Nine levels of pre-alarm sensitivity can also be selected, based on predeter- mined levels of alarm. Pre-alarm operation can be latching or self-restoring, and can be used to activate special control func- tions. Self-Optimizing Pre-Alarm. Each detector may be set for "Self-Optimizing" pre-alarm. In this special mode, the detector "learns" its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks. Cooperating Multi-Detector Sensing. A patented feature of ONYX Intelligent Sensing is the ability of a smoke sensor to consider readings from nearby sensors in making alarm or pre-alarm decisions. Without statistical sacrifice in the ability to resist false alarms, it allows a sensor to increase its sensitivity to actual smoke by a factor of almost two to one. DN-7070:P • 3/8/17 - Page 3 of 8 Field Programming Options Autoprogram is a timesaving feature. The FACP "learns" what devices are physically connected and automatically loads them in the program with default values for all parameters. Requiring less than one minute to run, this routine allows the user to have almost immediate fire protection in a new installa- tion, even if only a portion of the detectors are installed. Keypad Program Edit. The NFS2-3030, like all NOTIFIER intelligent panels, has the exclusive feature of program cre- ation and editing capability from the front panel keypad, while continuing to provide fire protection. The architecture of the NFS2-3030 software is such that each point entry carries its own program, including control-by-event links to other points. This allows the program to be entered with independent per- point segments, while the NFS2-3030 simultaneously monitors other (already installed) points for alarm conditions. VERIFIRE® TOOLS VeriFire® Tools is an offline programming and test utility that can greatly reduce installation programming time, and increase confidence in the site-specific software. It is Win- dows® based and provides technologically advanced capabili- ties to aid the installer. The installer may create the entire program for the NFS2-3030 in the comfort of the office, test it, store a backup file, then bring it to the site and download from a laptop into the panel. Product Line Information "Configuration Guidelines" on page 4 "Main System Components" on page 4 "Networking Options" on page 4 "Auxiliary Power Supplies and Batteries" on page 4 "Audio Options" on page 5 "Compatible Devices, EIA-232 Ports" on page 5 "Compatible Devices, EIA-485 Ports" on page 5 "Compatible Intelligent Devices" on page 5 "Enclosures, Chassis, and Dress Plates" on page 6 "Other Options" on page 7 CONFIGURATION GUIDELINES Stand-alone and network systems require a main display. On single-FACP systems (one NFS2-3030D), the display option is the CPU2-30300. On network systems (two or more net- worked fire panel nodes), at least one NCA-2, NCS, or ONYX- Works annunciation device is required. Options listed as follows. MAIN SYSTEM COMPONENTS CPU2-3030D: NFS2-3030 Primary Display. CPU2-3030D ships with keypad/display installed; includes 640-character backlit LCD display, QWERTY programming and control key- pad. CPU2-3030 is a central processing unit and requires an AMPS-24(E) power supply. For English ULC applications, use CPU2-3030DC. Non-English versions are available: CPU2- 3030D-FR, CPU2-3030D-HE, CPU2-3030D-KO, CPU2- 3030D-PO, CPU2-3030D-SC, CPU2-3030D-SP, CPU2- 3030D-TC, and CPU2-3030D-TH. For English Marine applica- tions order CPU2-3030D-M; for non-English Marine applica- tions order CPU2-3030D-M and the appropriate KP-KIT-XX. (See DN-60688.) CPU2-3030ND: CPU2-3030 without display. Non-English ver- sions are available: CPU2-3030ND-FR, CPU2-3030ND-HE, CPU2-3030ND-KO, CPU2-3030ND-PO, CPU2-3030ND-SC, CPU2-3030ND-SP, CPU2-3030ND-TC. LCM-320: Loop Control Module. Provides one SLC. NFS2- 3030 supports up to five LCM-320s and five LEM-320 expand- ers for a total of ten SLCs. See DN-6881. LEM-320: Loop Expander Module. Expands an LCM-320. See DN-6881. SAMPLE SYSTEM: Four-loop NFS2-3030 with display: CPU2-3030D, DP-DlSF two BMP-1s, CHS-M3, two LCM- 320s, two LEM-320s, AMPS-24, SBB-A4, DR-A4, BP2-4, BB- 100, batteries. NETWORKING OPTIONS NCA-2: Network Control Annunciator, 640 characters. An alternate primary display for CPU2-3030 can be provided by the NCA-2, NCS, or ONYXWorks. Using NCA-2 as primary display enables non-English languages. On network systems (two or more networked fire panel nodes), one network display (either NCA-2, NCS, or ONYXWorks) is required for every sys- tem. On network systems, the NCA-2 connects (and requires) a standard Network Communication Module or High-Speed Network Communication Module. Mounts in a row of FACP node or in two annunciator positions. Mounting options include the DP-DISP, ADP-4B, or in an annunciator box, such as the ABS-2D. In CAB-4 top-row applications, a DP-DISP and two BMP-1 blank modules are required for mounting. Non-English versions are available: NCA-2-FR, NCA-2-HE, NCA-2-KO, NCA-2-PO, NCA-2-SC, NCA-2-SP, NCA-2-TC, NCA-2-TH. For English ULC applications, order NCA-2C; for marine applica- tions, order NCA-2-M; for non-English marine applications order NCA-2-M and appropriate KP-KIT-XX. See DN-7047. NCM-W, NCM-F: Standard Network Communications Mod- ules. Wire and multi-mode fiber versions available. See DN- 6861. HS-NCM-W/MF/SF/WMF/WSF/MFSF: High-speed Network Communications Modules that can connect to two nodes. Wire, single-mode fiber, multi-mode fiber, and media conver- sion models are available. See DN-60454. RPT-W, RPT-F, RPT-WF: Standard-network repeater board with wire connection (RPT-W), multi-mode fiber connection (RPT-F), or allowing a change in media type between wire and fiber (RPT-WF). Not used with high-speed networks. See DN- 6971. ONYXWorks: UL-listed graphics PC workstation, ONYXWorks GUI software, and computer hardware. See DN-7048 for spe- cific part numbers. NFN-GW-EM-3: NFN Gateway, embedded. (Replaces NFN- GW-EM.) See DN-60499. NWS-3: NOTI'FIRE.NETTM Web Server. See DN-6928. CAP-GW: Common Alerting Protocol Gateway. See DN- 60756. VESDA-HLI-GW: VESDAnet high-level interface gateway. See DN-60753. LEDSIGN-GW: UL-listed sign gateway. Interfaces with classic and high-speed NOTI'FIRE.NET networks through the NFN Gateway. See DN-60679. OAX2-24V: UL-listed LED sign, used with LEDSIGN-GW. See DN-60679. AUXILIARY POWER SUPPLIES AND BATTERIES AMPS-24(E): One required for each NFS2-3030. Addressable power supply and battery charger with two 24 VDC outputs. Addressable by any FlashScan® or CLIP mode FACP. Charges 7 to 200 AH batteries. Occupies up to five addresses on an SLC, depending on configuration. Primary input power for panel. See DN-6883. APS2-6R: Auxiliary Power Supply. Provides up to 6.0 amperes of power for peripheral devices. Includes battery input and Page 4 of 8— DN-7070:P • 3/8/17 transfer relay, and overcurrent protection. Mounts on two of four positions on a CHS-4L or CHS-4 chassis. See DN-5952. ACPS-610: 6.0 A or 10.0 A addressable charging power sup- ply. See DN-60244. FCPS-24S6/-24S8: Remote 6 A and 8 A power supplies with battery charger. See DN-6927. BAT Series: Batteries. AMPS-24 uses two 12 volt, 7 to 200 AH batteries. See DN-6933. AuDio OPTIONS NOTE: See "Enclosures, Chassis, and Dress Plates" on page 6 for mounting hardware. DVC-EM: Digital Voice Command, digital audio processor with message storage for up to 32 minutes of standard quality (4 minutes at high quality) digital audio. See DN-7045. DVC-RPU: Digital Voice Command Remote Paging Unit for use with DVC-EM. Includes the keypad/display. See DN- 60726. DS-DB: Digital Series Distribution Board, provides bulk ampli- fication capabilities to the DVC-EM while retaining digital audio distribuition capabilities. Can be configured with up to four DS- AMPs, supplying high-level risers spread throughout an instal- lation. See DN-60565. DVC-KD: DVC-EM keypad for local annunciation and controls; status LEDs and 24 user-programmable buttons. See ON- 7045. DS-AMP/E: 125W, 25 VRMS, or 100W, 70VRMS. 70VRMS requires DS-XF70V step-up transformer. Digital Series Ampli- fier, part of the DS-DB system. See DN-60663. DS-RFM, DS-FM, DS-SFM: Fiber conversion modules for DVC-EM, DS-DB distribution board, and DAA2/DAX Series amplifiers. See DN-60633. DAA2-5025(E): 50W, 25 Vrms Digital Audio Amplifier assem- bly with power supply; includes chassis. See DN-60556. DAA2-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assembly with power supply; includes chassis. See DN-60556. DAA2-7525(E): 75W, 25 Vrms digital audio amplifier assembly with power supply; includes chassis. See DN-60556. DAX-3525(E): 35W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-3570(E): 35W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. DAX-5025(E): 50W, 25 Vrms Digital Audio Amplifier assembly with power supply, includes chassis. See DN-60561. DAX-5070(E): 50W, 70.7 Vrms Digital Audio Amplifier assem- bly with power supply, includes chassis. See DN-60561. TELH-1: Firefighter's Telephone Handset for use with the DVC-EM when mounted in the CA-2 chassis. See DN-7045. CMIC-1: Microphone used with DVC/DVC-EM. Included with CA-2 chassis assembly. See DN-7045. RM-1/RM-1SA: Remote microphone assemblies, mount on ADP-4 (RM-1) dress panel or CAB-RM/-RMR (RM-1SA) stand-alone cabinets. See DN-6728. AA-30: Audio Amplifier, 30 watts, 25 Vrms. Includes amplifier and audio input supervision, backup input, and automatic swi- tchover, power supply, cables. See DN-3224. AA-120/AA-100: Audio Amplifier. AA-120 is 120 watts, 25 Vrms. AA-1 00 is 100 watts, 70.7 Vrms. The amplifier contains an integral chassis for mounting to a CAB-134, -C4, or -D4 backbox (consumes one row). Includes audio input and ampli- fied output supervision, backup input, and automatic switcho- ver to backup tone. See DN-3224. DAA Series Digital Audio Amplifiers: Legacy DAA Series amplifiers are compatible with DVC systems running 5R4.0. For specific information on DAA-50 series amplifiers, refer to DN-7046. For information on DAA-7525 Series, refer to DN- 60257. COMPATIBLE DEVICES, EIA -232 PORTS PRN-7: 80-column printer. See DN-60897 VS4095/5: Printer, 40-column, 24 V. Order from Keltron, Inc. See DN-3260. DPI-232: Direct Panel Interface, specialized modem for extending serial data links to remotely located FACPs and/or peripherals. See DN-6870. COMPATIBLE DEVICES, EIA -485 PORTS ACM-24AT: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED, Trouble LED, and switch per circuit. Active/Alarm LEDs can be programmed (by powered-up switch selection) by point to be red, green, or yel- low; the Trouble LED is always yellow. See DN-6862. AEM-24AT: Same LED and switch capabilities as ACM-24AT; expands the ACM-24AT to 48, 72, or 96 points. See DN-6862. ACM-48A: ONYX® Series ACS annunciator - up to 96 points of annunciation with Alarm or Active LED per circuit. Active/ Alarm LEDs can be programmed (by powered-up switch selec- tion) in groups of 24 to be red, green, or yellow. Expandable to 96 points with one AEM-48A. See DN-6862. AEM-48A: Same LED capabilities as ACM-48A; expands the ACM-48A to 96 points. See DN-6862. ACM-8R: Remote Relay Module with eight Form-C contacts. Can be located up to 6,000 ft. (1828.8 m) from panel on four wires. See DN-3558. LCD-160: Liquid Crystal Display annunciator, 160-character backlit. Can store character sets for multiple languages. LCD- 160C is used for ULC applications. See DN-6940. LCD2-80: Terminal and ACS mode. 80-character, backlit LCD display. Mounts up to 6,000 ft. (1828.8 m) from panel. Up to 32 per FACP. See LCD2-80 (DN-60548). SCS Series: Smoke control station; eight (expandable to 16) circuits. See DN-4818. TM-4: Transmitter Module. Includes three reverse-polarity cir- cuits and one municipal box circuit. Mounts in panel module position (as in single-address mode applications) or in CHS- M3 position. See DN-6860. UDACT-2: Universal Digital Alarm Communicator Transmitter, 636 channel. See DN-60686. UZC-256: Programmable Universal Zone Coder provides pos- itive non-interfering successive zone coding. Microprocessor- controlled, field-programmable from lBM-compatible PCs (requires optional programming kit). Mounts on a CHS-4 series chassis within NFS2-3030. COMPATIBLE INTELLIGENT DEVICES NOTE: "A" suffix indicates ULC-Listed model. FWSG Wireless SWIFT Gateway: Addressable gateway sup- ports wireless SLC devices. Not appropriate for ULC applica- tions. See DN-60820. FSA-5000: Intelligent FAAST® XS Fire Alarm Aspiration Sens- ing Technology. Intelligent aspirating smoke detector for appli- cations up to 5,000 sq.ft. For Canadian applications, order FSA-5000A. FSA-8000: Intelligent FAAST® XM Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 8,000 sq.ft. For Canadian applications, order FSA-8000A. See DN-60792. DN-7070:P • 3/8/17 - Page 5 of 8 FSA-20000: Intelligent FAAST® XI Fire Alarm Aspiration Sensing Technology. Intelligent aspirating smoke detector for applications up to 28,800 sq.ft. For Canadian applications, order FSA-20000A. See DN-60849. FSA-20000P FAAST® XT PRO Intelligent Aspiration Detector For applications up to 28,800 sq. ft. (2601 sq. m.) through one to four addressable pipes. See DN-60792 FSB-200(A): Intelligent beam smoke detector. See DN-6985. FSB-200S(A): Intelligent beam smoke detector with integral sensitivity test. See DN-6985. FSC-851(A): FlashScan IntelliQuad Advanced Multi-Criteria Detector. See DN-60412. FCO-851(A): FlashScan IntelliQuad PLUS Advanced Multi-Cri- teria Fire/CO Detector. See DN-60689. FSI-851(A): Low-profile FlashScan ionization detector. See DN-6985. FSP-851 (A): Low-profile FlashScan photoelectric detector. See DN-6935. FSP-851R(A): Low-profile intelligent photoelectric sensor, remote test capable. For use with DNR(W). See DN-6935. FSP-851T(A): Low-profile FlashScan photoelectric detector with 135°F (57°C) thermal. See DN-6935. FST-851(A):: FlashScan thermal detector 135°F (57C). See DN-6936. FST-851R(A): FlashScan thermal detector 135°F (57°C) with rate-of-rise. See DN-6936. FST-851H(A): FlashScan 190°F (88°C) high-temperature ther- mal detector. See DN-6936. FAPT-851(A): FlashScan Acclimate PlusTM low-profile multi- sensor detector. See DN-6937. FSL-751(A): FlashScan VIEW® laser photo detector. See DN- 6886. DNR(A): InnovairFIex low-flow non-relay duct-detector housing (order FSP-851 separately). Replaces FSD-751 PLJFSD- 751 RPL. See DN-60429. DNRW(A): Same as above with NEMA-4 rating, watertight. See DN-60429. B224RB: Low-profile relay base. See DN-60054. B224B1: Isolator base for low-profile detectors. See DN- 60054. B21OLP: Low-profile base. Standard U.S. style. Replaces B71OLP. See DN-60054. B501(A): European-style, 4° (10.16 cm) base. See DN-60054. B200S: Intelligent programmable sounder base, capable of producing a variety of tone patterns including ANSI Temporal 3. Compatible with sychronization protocol. See DN-60054. B200S-LF: Low-frequency version of B200S. See DN-60054. B200SCOA: Based on B200SA, with added CO detector markings in English/French. For Canadian applications only. B200SR: Sounder base, Temporal 3 or Continuous tone. See DN-60054. B200SR-LF: Low-frequency version of B200SR. See DN- 60054. FMM-1(A):: FlashScan monitor module. See DN-6 720. FDM-1(A): FlashScan dual monitor module. See DN-6 720. FZM-1(A): FlashScan two-wire detector monitor module. See DN-6 720. FMM-101(A): FlashScan miniature monitor module. See ON- 6720. FMM-4-20: FlashScan 4-20 mA protocol monitor module. See DN-60411. FCM-1(A): FlashScan control module. See DN-6 724. FCM-1-REL(A): FlashScan releasing control module. See ON- 60390. FTM-1(A): Firephone Telephone Module connects a remote firefighter telephone to a centralized telephone console. Reports status to panel. Wiring to jacks and handsets is super- vised. See DN-6989. FRM-1(A): FlashScan relay module. See DN-6724. FDRM-1(A): FlashScan dual monitor/dual relay module. See DN-60709. NBG-12LX: Manual pull station, addressable. See ON-6 726. ISO-X: Isolator module. See ON-2243. ISO-6: Six Fault isolator module. For Canadian applications order ISO-6A. See DN-60844. X136-C(A): FlashScan six-circuit supervised control module. See DN-6924. XP6-MA(A): FlashScan six-zone interface module; connects intelligent alarm system to two-wire conventional detection zone. See DN-6925. XP6-R(A): FlashScan six-relay (Form-C) control module. See DN-6926. XP10-M(A): FlashScan ten-input monitor module. See ON- 6923. SLC-IM: SLC integration module, for VESDAnet detectors. See DN-60755. ENCLOSURES, CHASSIS, AND DRESS PLATES CAB-4 Series Enclosure: NFS2-3030 mounts in a standard CAB-4 Series enclosure (available in four sizes, "A" through "D"). Backbox and door ordered separately; requires BP2-4 battery plate. A trim ring option is available for semi-flush mounting. See DN-6857. EQ Series Cabinets: EQ series cabinets will house amplifiers, power supplies, battery chargers and control modules. EQ cabinets are available in three sizes, "B" through "D". See ON- 60229. CAB-BM Marine System: Protects equipment in shipboard and waterfront applications. Order CPU2-3030D-M; for non- English marine applications order CPU2-3030D and appropri- ate KP-KIT-XX. Also order BB-MB for systems using 100 AH batteries. For a full list of required and optional equipment, see DN-60688. CHS-M3: Mounting chassis for CPU2-3030. One required for each CPU2-3030D/3030ND. CA-2: Chassis for FACP control panel when DVC-EM is used with firefighter's telephone. Mounts in the top two rows of a CAB-4 series enclosure. DP-DISP: Dress panel for top row in cabinet with CPU2- 3030D installed. D13-113: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. See ON-7046. CHS-131-11: Battery chassis; holds two 12.0 AH batteries. Mounts on the left side of DAA2 chassis. See DN-7046. CA-11: Chassis, occupies one tier of a CAB-4 Series enclosure. The left side accommodates one DVC-EM and a DVC-KD (optional); and the right side houses a CMIC-1 microphone and its well (optional). See DN-7045. CA-2: Chassis assembly, occupies two tiers of a CAB-4 Series enclosure. The left side accommodates one DVC-EM mounted Page 6 of 8- DN-7070:P • 3/8/17 on a half-chassis and one NFS2-3030 or NCA-2 mounted on a half-chassis. The right side houses a microphone/handset well. The CA-2 assembly includes CMIC-1 microphone. ADDR Series doors with two-tier visibility are available for use with the CA-2 configuration: ADDR-134, ADDR-C4, ADDR-D4 (below). ADDR-134: Two-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-B4 backbox with the ADDR-134. See DN-7045, DN-6857. ADDR-C4: Three-tier-sized door designed for use with the CA- 2 chassis configuration. ADDR Series doors are similar to CAB-4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-C4 backbox with the ADDR-C4. See DN-7045, DN-6857. ADDR-134: Four-tier-sized door designed for use with the CA-2 chassis configuration. ADDR Series doors are similar to CAB- 4 Series "DR' doors, but a clear window space exposes the top two tiers of the CAB-4 enclosure. Use an SBB-D4 backbox with the ADDR-D4. See DN-7045, DN-6857. DPA-1: Dress panel, used with the CA-1 chassis when config- ured with a DVC-EM, DVC-KD, and CMIC-1. See DN-7045. DPA-2: Dress Panel used with the CA-2 chassis assembly. DPA-1A4: Dress panel, used with the CA-1 chassis when the CMlC-i is not used. Provides mounting options on right two bays for two ACS annunciators, or for blank plates. See DN- 7045. ADP-4B: Annunciator dress plate. Mounts in rows 2, 3 or 4 of a CAB-4 series enclosure. Used with ACS series annuncia- tors. BMP-1: Blank module for unused module positions. DP-1B: Blank dress panel. Provides dead-front panel for unused tiers; covers DAA2/DAX series or AA-series amplifier. BP2-4: Battery plate, required. CHS-41L: Low-profile four-position Chassis. Mounts two AA-30 amplifiers. CHS-4N: Chassis for mounting up to four APS-6Rs. CHS-6: Chassis used with the XP6 and XP10 Multi-Modules. Mounts up to six modules in any CAB-4 series row. NFS-LBB: Battery Box. The NFS-LBB is used to mount up to two 55 AH batteries. Dimensions: Box: 24" (610 mm) wide x 14" (356 mm) high x 7.75" (197 mm) deep. Door: 24.125" (613 mm) wide x 14.25" (362 mm) high; door adds 0.0625" (approx. 1.6 mm) to depth. BACKBOXES NOTE: "C" suffix indicates ULC-Listed mode!. BB-100: Backbox for batteries and power supplies. The BB- 100 is used to mount up to two 100 AH batteries and power supply, if needed. 30" (76.20 cm) wide x 25' (63.50 cm) high x 7.5" (19.05 cm) deep; depth includes door. BB-200: Backbox for batteries and power supplies. Holds up to four 100 AH batteries (200 AH capacity) and power supply. 30" (76.20 cm) wide x 36' (91.44 cm) high x 7.5' (19.05 cm) deep; depth includes door. BB-UZC: Backbox for housing the UZC-256 for applications where the UZC will not fit in panel enclosure. Black; for red, order BB-UZC-R. See DN-3404. ABF-i B(C) Annunciator Flush Box ABF-1DB(C) Annunciator Flush Box with Door. ULIULC Listed. ABF-2B Annunciator Flush Box ABF-213B(C) Annunciator Flush Box with Door ABF-4B Annunciator Flush Box ABS-1TB(C) Annunciator Surface Box ABS-1 B(C) Annunciator Surface Box ABS-213 Annunciator Surface Box ABS-2D(C) Annunciator Surface Box ABS-4D(C) Annunciator Surface Box SEISKIT-CAB: Seismic mounting kit. Required for seismic- certified applications with NFS2-3030 and other equipment mounted in CAB-4 Series Enclosures. Includes battery bracket for two 26 AH batteries. SEISKIT-LBB: Seismic kit for the NFS-LBB. Includes battery bracket for two 55 AH batteries. OTHER OPTIONS 411: Slave digital alarm communicator. See DN-6619. 411 UDAC: Digital alarm communicator. See DN-6746. IPDACT-2, IPDACT Internet Monitoring Module: Connects to primary and secondary DACT telephone output ports for internet communications over customer-provided Ethernet connection. Requires compatible Teldat VisorALARM Central Station Receiver. Can use DHCP or static IP. See DN-60408. IPCHSKIT: IP Communicator Chassis Mounting Kit. For mounting an IPDACT-2/2UD onto the panel chassis or CHS-4 series chassis. Use IPENC for external mounting applications. IPSPLT: Y-adapter option allow connection of both panel dialer outputs to one IPDACT-2/2UD cable input. IPENC: External enclosure for IPDACT, includes IPBRKT mounting bracket; Red; for black, order IPENC-B. IPGSM-4G: Internet and Digital Cellular Fire Alarm Communica- tor. Provides selectable configurable paths: cellular only, I only, or IP primary with cellular backup. Connects to the primary and secondary ports of a DACT. For Canadian applications order IPGSM-4GC. See DH-60769. NOTE: For other options including compatibility with retrofit equip- ment, refer to the panels installation manual, the SLC manual, and the Device Compatibility Document. System Specifications SYSTEM CAPACITY Intelligent Signaling Line Circuits ...........1 expandable to 10 Intelligent detectors ..........................................159 per loop Addressable monitor/control modules..............159 per loop Programmable software zones.............................over 2000 ACS annunciators per CPU2-3030 .......................32 address x 64 or 96 points NOTE: The CPU2-3030 can support up to 96 annunciator address points per ACM-24AT/-48A. SPECIFICATIONS Primary Input Power: - AMPS-24:110-120 VAC, 50/60 Hz, 4.5 A maximum. - AMPS-24E: 240 VAC, 50/60 Hz, 2.25 A maximum. DC Output: - Main 24 VDC: Up to 5.0 A - Aux 24 VDC: Up to 5.0 A -5VDC: Up to 0.15 A. Current draw (Standby/Alarm): - CPU2-3030D board: 0.340 A. - CPU2-3030ND board: 0.120 A. - LCM-320: 0.130 A. - LEM-320: 0.100 A. DN-7070:P • 3/8/17 - Page 7 of 8 -AMPS-24(E)*: 0.13 A. (Draws power from secondary power source only.) NOTE: See AMPS-24(E) Manual 51907 for a complete current draw calculation sheet and details of input and output values. Battery charger range: 7 AH —200 AH. Use separate cabinet for batteries over 26 AH. Float Rate: 27.6 V. SHIPPING WEIGHT CPU2-3030D: 5.95 lb (2.70 kg). CPU2-3030ND: 2.90 lb (1.32 kg). TEMPERATURE AND HUMIDITY RANGES This system meets NFPA requirements for operation at 0 - 49°C/32 - 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme tempera- ture ranges and humidity. Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15— 27°C160 - 80°F AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. STANDARDS The NFS2-3030 complies with the following UL Standards and NFPA 72, International Building Code (IBC), and California Building Code (CBC) Fire Alarm Systems requirements: UL 864 (Fire). UL 1076 (Burglary). UL 2572 (Mass Notification Systems). (NFS2-3030 version 20 or higher) ULC-S527-11 Standard for the Installation of Fire Alarm Sys- tems. LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervisory). AUXILIARY (Automatic, Manual and Waterflow) (requires TM-4). REMOTE STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory) (requires TM-4). PROPRIETARY (Automatic, Manual, Waterflow and Sprin- kler Supervisory). Not applicable for FM. EMERGENCY VOICE/ALARM. OT, PSDN (Other Technologies, Packet-switched Data Net- work). IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seis- mic). CBC 2007 (Seismic). UL Listed: S635. ULC Listed: S527-11. MEA: 232-06-E. Fire Dept. of New York: COA#621 1. CSFM: 7165-0028:0224 (Commercial). FM Approved. FM6320 Approved. Class 6320 for Gas Detection. City of Chicago. City of Denver. Singapore Productivity and Standards Board (PSB). CCCF listed. Fire Services Department (Hong Kong). Marine Applications: Marine approved systems must be con- figured using components itemized in this document. (See Main System Components, in "Product Line Information.) Spe- cific connections and requirements for those components are described in the installation document, PN 54756. When these requirements are followed, systems are approved by the fol- lowing agencies: US Coast Guard 161.002/55/0 (Standard 46 CFR and 161.002). Lloyd's Register 11/600013 (ENV 3 category). American Bureau of Shipping (ABS) Type Approval. NOTE: For information on marine applications, see DN-60688. IntelliQuadTM, NOTI.FIRE.NETTM, ONYXWorksTM and SWIFT TM are all trademarks; and Acclimate® PIusTM, FlashScan, Intelligent FAAS1®, NOTIFIER®, ONYX®, VeriFire® Tools, and VIEW® are all registered trademarks of Honeywell International Inc. 02017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EIIIIIIIIIEMNS & MANIFACHER All specifications are subject to change without notice. QUALITY SYSTEMS Country ot Origin: USA For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 8 of 8— DN-7070:P • 3/8/17 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0028:0222 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models* DPI -232 Direct Panel Interface Module. Model DPI -232 extends EIA -232 serial data lines between control panels and/or peripherals. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. NOTE: *Rec 4-13-2006 JW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct V' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6927:A2 FCPS.24S6(C/E) & FCPS. 24S8(CIE) 6- & 8-Amp 24-Volt Remote Power SuDolies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger. The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- ries. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B (Style Y) or Class A (Style Z, with ZNAC-4 option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-2456/-2458 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C & FCPS-2458C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E Features UL-Listed NAC synchronization using System Sensor, Wheelock, or Gentex "Commander2" appliances. Operates as a "sync-follower" or as a "sync-generator" (default). See note on page 2. Contains two fully-isolated input/control circuits - triggered from FACP NAC (NAC expander mode) or jumped perma- nently "ON" (stand-alone mode). Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module) NACs. 6-amp (FCPS-2456) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous output in stand-alone mode (UL 1481). Compatible with coded inputs; signals passed through. Optional power-supervision relay (EOLR-1). In stand-alone mode, output power circuits may be config- ured as: resettable, (reset line from FACP required), non-resettable, or a mix of two and two. Fully regulated and filtered power output - optimal for pow- ering four-wire smoke detectors, annunciators, and other system peripherals requiring regulated/filtered power. Power-limiting technology meets UL power-limiting require- ments. Form-C normally-closed trouble relay. Fully supervised power supply, battery, and NACs. Selectable earth fault detection. AC trouble report selectable for immediate 2-hour delay. Works with virtually any UL 864 fire alarm control which uti- lizes an industry-standard reverse-polarity notification cir- cuit (including unfiltered and unregulated NAC power). Requires input trigger voltage of 9 - 32 VDC. Self-contained in compact, locking cabinet - 15"H x 14.5W x 2.75"D (cm: 38.1 H x 36.83W x 6.985D). NOTIFIER® by Honeywell Includes integral battery charger capable of charging up to 18 AH batteries. Cabinet capable of housing 7.0 AH batter- ies. Battery charger may be disabled via DIP switch for applica- tions requiring larger batteries. Fixed, clamp-type terminal blocks accommodate up to 12 AWG (3.1mm2) wire. Specifications Primary (AC) Power: FCPS-24S6C/-2458C: 120 VAC, 60 Hz, 3.2A maximum. FCPS-2456E/-2458E: 240 VAC, 50 Hz, 1.6A maximum. Wire Size: minimum #14 AWG (2.0mm2) with 600 V insula- tion. Control Input Circuit: Trigger Input Voltage: 9 to 32 VDC. Trigger Current: 2.0 mA (16-32 V); Per Input: 1.0 mA (9 - 16 V). Trouble Contact Rating: 5 A at 24 VDC. Auxiliary Power Output: Specific application power 500 mA maximum. Output Circuits: +24 VDC filtered, regulated. 3.0 A maximum for any one circuit. Total continuous current for all outputs (stand-alone mode): - FCPS-2456: 4.0 A maximum. - FCPS-2458: 6.0 A maximum. Total short-term current for all outputs (NAC expander mode): - FCPS-2456: 6.0 A maximum. - FCPS-24S8: 8.0 A maximum. Secondary Power (Battery) Charging Circuit: Supports lead-acid batteries only. DN-6927:A2 • 5/17/13 - Page 1 of 2 Float-charge voltage: 27.6 VDC. Maximum current charge: 1.5 A. Maximum battery capacity: 18 AH. Applications Example 1: Expand notification appliance power an additional 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example, the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the FACP through the notification appliance circuit. Example 2: Use the FCPS to expand auxiliary regulated 24- volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A (FCPS-2458). Both resettable and non-resettable power options are available. Resettable outputs are created by con- necting the resettable output from the FACP to one or both of the FCPS inputs. Example 3: Use addressable control modules to activate the FCPS instead of activating it through the FACP notification appliance circuits. This typically allows for mounting the FCPS at greater distances* away from the FACP while expanding system architecture in various applications. For example, an addressable control module is used to acti- vate the FCPS, and an addressable monitor module is used to sense FCPS trouble conditions. Local auxiliary power output from the FCPS provides power to the addressable control module. "NOTE: Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet (3,810 meters). Sync Follower/Generator Note In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance. Strobes accomplish this by monitoring very short timing pulses on the NAC power which are created by the FACP. When installed at the end of a NAC wire run, the FCPS-2456/-24S8 can track (i.e. "follow") the strobe synchronization timing pulses on the existing NAC wire run. This maintains the overall system flash timing of the additional strobes attaches to the FCPS. When the FCPS-2456/-2458 is configured (via DIP switch set- tings) as a "sync follower," the FCPS's NAC outputs track the strobe synchronization pulses present at the FCPS's sync input terminal. The pulses originate from an upstream FACP or other power supply. When the FCPS-2456/-2458 are configured (via DIP switch settings) as a "sync generator," the FCPS's sync input termi- nals are not used. Rather, the FCPS is the originator of the strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator" mode, the sync type (System Sensor, Whee- lock, or Gentex) is selectable via DIP switch settings. Standards and Codes The FCPS-2456 and FCPS-2458 comply with the following standards: NFPA 72 National Fire Alarm Code. UL 864 Standard for Control Units for Fire Alarm Systems (NAC expander mode). UL 1481 Power Supplies for Fire Alarm Systems. Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S635, S674 ULC Listed: S635 (FCPS-2456C & FCPS-2458C) CSFM Approved: 7315-0028:225 MEA: 299-02-E FM Approved Ordering Information FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5"W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S6C: Same as above, ULC-listed. FCPS-24S6R: Same as FCPS-2456 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1 H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. FCPS-24S8C Same as above, ULC-listed. FCPS-24S8R: Same as FCPS-2458 with red enclosure. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure (15"H x 14.5W x 2.75"D [cm: 38.1H x 36.83W x 6.985D]), and installation instructions. ZNAC-4: Class A (Style Y) NAC option module. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire smoke detector power. BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT Series data sheet DN-6933). System Sensor® and NOTIFIER® are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I SO 9001 We try to keep our product information up-to-date and accurate. - • , We cannot cover all specific applications or anticipate all requirements. MCINERINS A MANIMC1WNG All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6927:A2 • 5/17/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7315-0028:0225 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models FCPS-24S6 and FCPS-24S8 are power limited power supply/battery chargers used for supervision and expanded power driving capability of up to four Notification Appliance Circuits (FACP Fire Circuits, Signaling Devices) or resettable/non resettable outputs. Model ZNAC-4 Class A converter. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 VAC, 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as a Power Supply/Battery Charger for use with separately listed compatible fire alarm control units. XLF: 7315-0075:0206 1-24-03KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division dn-71 14:c • Al -65 NOTIFIER® by Honeywell 80-Character LCD Serial Annunciator General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. N-ANN-80 is black; for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point information including device type, zone, independent point alarm, trouble or supervisory status, as well as any custom alpha labels programmed into the control panel. It includes con- trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-BUS of each FACP. Minimal programming is required, which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACP5 with an ANN-BUS, such as the NFW-50. Features Listed to UL Standard 864, 9th Edition. Backlit 80-character LCD display (20 characters x 4 lines). Mimics all display information from the host panel. Control switches for System Acknowledge, Signal Silence, Drill, and Reset. Control switches can be independently enabled or disabled at the FACP. Keyswitch enables/disables control switches and mechani- cally locks annunciator enclosure Keyswitch can be enabled or disabled at the FACP. Enclosure supervised for tamper. System status LEDs for AC Power, Alarm, Trouble, Supervi- sory, and Alarm Silence. Local sounder can be enabled or disabled at the FACP. N-ANN-80 connects to the ANN-BUS terminal on the FACP and requires minimal panel programming. Displays device type identifiers, individual point alarm, trou- ble, supervisory, zone, and custom alpha labels. Time-and date display field. Surface mount directly to wall or to single, double, or 4' square electrical box. Semi-flush mount to single, double, or 4° square electrical box. Use ANN-SBBOKIT for angled view mounting. Can be remotely located up to 6,000 feet (1,800 m) from the panel. Backlight turns off during AC loss to conserve battery power but will turn back on if an alarm condition occurs. May be powered by 24 VDC from the host FACP or by remote power supply (requires 24 VDC). Up to eight N-ANN-805 can be connected on the ANN-BUS. Controls and Indicators AC Power Alarm Trouble Supervisory Alarm Silenced Specifications Operating voltage range: 18 VDC to 28 VDC. Current consumption @ 24 VDC nominal (filtered and non- resettable): 40 mA maximum. Ambient temperature: 32°F to 120°F (0°C to 49°C). Relative humidity: 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). 5.375" (13.65 cm.) high x 6.875" (17.46 cm.) wide x 1.375' (3.49 cm.) deep. For use indoors in a dry location. All connections are power-limited and supervised. Agency Listings and Approvals The listings and approvals below apply to the N-ANN-80. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL: S635 FM approved CSFM: 7120-0028:240 MEA: 442-06-E Vol. 2 The ANN-BUS POWERING THE DEVICES ON THE ANN-BUS FROM AUXILIARY POWER SUPPLY The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the ANN-BUS power requirements. See the FACP manual for more information. dn-71 14:c • 5/22/09 - Page 1 of 2 ANN-BUS DEVICE ADDRESSING Each ANN-BUS device requires a unique address (ID Number) in order to communicate with the FACR A maximum of 8 devices can be connected to the FACP ANN-BUS communication circuit. See the FACP manual for more information. WIRE REQUIREMENTS: COMMUNICATIONS CIRCUIT The N-ANN-80 connects to the FACP ANN-BUS communica- tions circuit. To determine the type of wire and the maximum wir- ing distance that can be used with FACP ANN-BUS accessory modules, it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus. The total worst case current draw is calculated by adding the individual worst case currents for each module. NOTE: For total worst case current draw on a single ANN-BUS refer to appropriate FACP manual. After calculating the total worst case current draw, the following table specifies the maximum distance the modules can be located from the FACP on a single wire run. The table ensures 6.0 volts of line drop maximum. In general, the wire length is lim- ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. These cases are marked in the chart with an asterisk (*) Maxi- mum length can never be more than 6,000 feet (1,800 m), regardless of gauge used. See table below. WIRE REQUIREMENTS: POWER CIRCUIT 14 to 18 AWG (0.75 - 2.08 mm2) wire for 24 VDC power cir- cuit is acceptable. All connections are power-limited and supervised. A maximum of eight N-ANN-80 modules may be connected to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Current Draw (amps) 22 Gauge 18 Gauge 16 Gauge 14 Gauge 0.100 1,852 ft. 4,688 ft. * 6,000 ft. *6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000 (max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION The following figure illustrates the wiring between the FACP and ANN-BUS devices. ANN-BUS and power wiring are supervised and power limited. BA+- TBI ANN-BUS Device AB 0 NFW-50 TB 12345678 FACP Wiring to ANN-BUS Device ORDERING OPTIONS: N-ANN-80: Black 80 character LCD Annunciator. N-ANN-80-W: White, 80 character LCD Annunciator. ANN-SB80KIT-B: Black surface mount backbox with angled wedge. ANN-SB80KIT-W: White surface mount backbox with angled wedge. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. I so 9001 We try tc keep our product information up-to-date and accurate. • We cannot cover all specific applications or anticipate all requirements. R6INIUIN All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notitier.com Page 2 of 2— dn-71 14:c • 5/22/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7120-0028:0240 Page 1 of I CATEGORY: 7120--ANNUNCIATORS LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Models N-ANN-80 and *N ANN 80W remote fire annunciators. Unit is a 80-character, supervised backlit LCD fire annunciator. Communication between the control panel and the annunciator is accomplished over a two-wire serial interface employing the ANN-BUS protocol. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listees name, product number, electrical rating and UL label. APPROVAL: Listed as an annunciator for use separately listed compatible fire alarm control units. Refer to manufacturer's installation manual for details. XLF: 7120-0075:0211 *Rev 12-11-14 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6985:C • H-212 FSB-200(A) and FSB-200S(A) Single-Ended, Reflector-Type Addressable Beam Smoke Detector GENERAL The Notifier FSB-200 and FSB-200S are intelligent, addressable reflected beam smoke detectors for protecting open areas with high and sloping ceilings, and wide-open areas, where spot-type smoke detectors are difficult to install and maintain. Ideal applications are atriums, cathedral ceilings, aircraft hangars, warehouses, sporting arenas, concert halls, and enclosed parking facilities. They are compatible with the NFS-3030, NFS2-3030, NFS-640, NFS2- 640, and NFS-320 in FlashScan® or CLIP mode, as well as legacy addressable panels. Installation of the single-ended reflective design is much quicker than a dual-ended projected beam detector. Alignment is easily accomplished with an optical sight and a two-digit signal strength meter incorporated into the beam detector. Listed for operation from —22°F to 131°F, the FSB-200 and FSB-200S are usable in open area applications where temperature extremes exceed the design limits of other types of smoke detection. The FSB-200 and FSB-200S are a transmitter/receiver unit and a reflector. When smoke enters the area between the unit and the reflector it causes a reduction in the signal strength. When the smoke level (signal strength) reaches the predetermined threshold, an alarm is activated. The detectors have four standard sensitivity selections as well as two Acclimate® settings. When either Acclimate® setting is selected, the detector's advanced software algorithms automatically adjust to the optimum sensitivity for the specific environment. The FSB-200S has an integral sensitivity test feature of a filter attached to a servomotor inside the detector optics. Activation of the RTS1 51 or RTS1 51 KEY remote test stations moves the filter into the pathway of the light beam, testing the detector's sensitivity. This sensitivity test feature allows the user to quickly and easily meet the annual maintenance and test requirements of NFPA 72, without physical access to the detector. The servomotor must be powered by +24 VDC, not SLC power. FEATURES Listed to UL 268, ULC CAN/ULC S529. Transmitter/receiver built into same unit. Six user-selectable sensitivity levels. 16' to 328' (use BEAMLRK beyond 230') protection range. Removable plug-in terminal blocks. Digital display - no special tools required. Built-in automatic gain control compensates for signal dete- rioration from dust buildup. Optional remote test station. Optional long-range kit (BEAMLRK) for applications in excess of 230'(70 m). Optional multi-mount kit (BEAMMMK) providing ceiling or wall mount capability with increased angular adjustment. Optional heater kits (BEAMHK and BEAMHKR) for prevention of condensation (not intended to increase or reduce the specified operating temperature). Paintable cover. NOTIFIER® by Honeywell FSB-200 with Reflective Plate 6975re11ect.jpg FSB-200 with BEAMMMK 6975bBarrnk.jpg - SPECIFICATIONS OPERATIONAL SPECIFICATIONS Protection Range: 16 to 230 feet (5 to 70 m), 230 to 328 feet (70 to 100 m) using optional BEAMLRK kit. Adjustment Angle: ±10° horizontal and vertical. Note that the optics move independently of the unit. Sensitivity (6 levels): NOTE: Sensitivity settings are a feature of specific control panels. Level —25%. Level 2-30%. Level 3-40%. Level 4-50%. Acclimate® Level 5 - 30% to 50%. Acclimate® Level 6 - 40% to 50%. Fault Condition (trouble): 96% or more obscuration blockage. In alignment mode. Improper initial alignment. Self-compensation limit reached. Alignment Aid: Optical gunsight. Integral signal strength indication. Two-digit display. Indicators: Alarm - local red LED and remote alarm. Trouble - local yellow LED and remote trouble. Normal - local flashing green LED. DN-6985:C• 11/16109—Page 1 of 4 Test/reset features: Integral sensitivity test filter (FSB-200S only, requires external power supply). Sensitivity filter (incremental scale on reflector). Local alarm test switch. Local alarm reset switch. Remote test and reset switch (compatible with RTS151 and RTS1 51 KEY test stations). Smoke Detector Spacing: On smooth ceilings, 30 - 60 feet (9.1 to 18.3 m) between projected beams and not more than one-half that spacing between a projected beam and a sidewall. Other spacing may be used depending on ceiling height, airflow characteristics, and response requirements. See NFPA 72. ENVIRONMENTAL SPECIFICATIONS Temperature: -22°F to 131°F (-30°C to 55°C). Humidity: 10-93% RH noncondensing. ELECTRICAL SPECIFICATIONS Voltage: 15 to 32 VDC. Average Standby Current (24 VDC): 2 mA maximum (LED flashing, SLC © 24 V). Alarm Current (LED on): 8.5 mA maximum. Trouble Current (LED on): 4.5 mA maximum. Alignment Current: 20 mA maximum. External Supply (FSB-200S only): Voltage - 15 to 32 VDC Current - 0.5 A maximum. Remote Output (Alarm): Voltage - 15 to 32 VDC (Output voltage same as device input voltage) Current - 15 mA maximum, 6 mA minimum (Output current is limited by 2.2K ohm resistor) Heater Kit BEAMHK: Voltage - 15 to 32 V; Current - 92 mA maximum © 32 V (heater only); Power Consumption - nominal 1.6W © 24 V, maximum 3.0W © 32 V. Reflector Heater Kit BEAMHKR: Voltage - 15 to 32 V; Current - 450 mA maximum © 32 V (per reflector); Power Consumption (per reflector) - nominal 7.7W © 24 V, maximum 15.0 W © 32 V. MECHANICAL SPECIFICATIONS Shipping Weight: 3.7 lbs (1.68 kg) Detector Dimensions: 10.0 H x 7.5° W x 3.3" D (254 mm H x 191 mmWx84mmD). Reflector Dimensions for 16 to 230' (5 to 70m) Applications: 7.9" x 9.1" (200 x 230 mm). Reflector Dimensions for Applications Beyond 230I70m: 15.7" x 18.1" (400 x 460 mm). SENSITIVITY SELECTION The detector has six sensitivity selections (sensitivity settings are a feature of specific control panels). Each of these selections is only acceptable over a specific distance separation between the detector and the reflector per UL 268. The chart below determines which selections are acceptable for your installed distance. The sensitivity of the detector can be set only when the housing is removed and the detector is not in the fine adjustment step of the alignment mode, indicated by the illumination of the dual digital display. To set the sensitivity, depress the sensitivity button one time. See Switch Locations diagram. Once the switch is pressed, the digital display will illuminate and read the current sensitivity setting in percent obscuration. To change the sensitivity, continue to depress the sensitivity switch until the desired setting is achieved. The digital display will turn off automatically if no further switch presses occur. Acceptable Acceptable DISTANCE DISTANCE Sensitivity Percent Display between between Detector Setting Obscuration Reading Detector and and Reflector Reflector Level 1 25% 25 16.4 to 120 5.0 to 36.6 Level 2 30% 30 25 to 150 7.6 to 45.7 Level 3 40% 40 60 to 220 18.3 to 67 Level 4 50% 50 80 to 328 24.410 100 Acclimate® 30% 1050% Al 8010 150 24.4 to 45.7 Level 1 Acclimate® 40% to 50% A2 80 to 200 24.4 to 67 Level 2 In addition to the four standard sensitivity selections, the detector has two Acclimate® settings. When either Acclimate® setting is chosen the detector will automatically adjust its sensitivity using advanced software algorithms to select the optimum sensitivity for the environment. The sensitivity will be continuously adjusted within the ranges specified in the chart above. Total obscuration can be converted to percent per foot, assuming uniform smoke density for the entire length of the beam. The chart below converts total obscuration percent per foot for all acceptable sensitivity settings. Page 2 of 4- DN-6985:C • 11/16/09 0 K 0 0 STYLES ISOLATOR SHUNTS (SHOWN S/SABLES) Switch Locations AI1MUROf tNDIAR SenshMty In Wt. vs. DFlaroa eiroueiero izrdkwm unhake dt,itiolioei 0 2M *.ffli Oictinoo in FanS Table 1: Total Obscuration H Remote Power Source* 1./sad an/v for FSB -2go. From Panel Communica TO Line e See electrical Or Previous 32 VOC Maximum Device ratings, device. Twisted pair is recommended Wiring Diagram FSB-200/FSB-200S .5 Pin 191 Remote Alarm Out Pin 2 AUX (-) I I Pin 4 Reset Input Pin 3 Test Input Pin 5 See RTS151/KEY Installation Instructions to act Si ratingsa/the RTS151/KEY RTS151/KEY Wiring Diagram with RTS151/KEY I LC ,iN nuss. Moral wuinceLRIJUVIAW S Alignment and Adjustment Locations PARTS LIST Item Quantity Transmitter/Receiver Unit 1 Paintable Trim Ring 1 Reflector 1 Plug-In Terminal Blocks 3 Isolator Shunts 2 Instruction Manual 1 Orange Sticky Paper 1 wallir VAITICIII Housing Screw Locations DN-6985:C • 11/16/09 - Page 3 of 4 B RTS1 51 KEY CTBB.1!11 iBEAMHK BEAMMMK RTS1 51 (ceiling or wall mount kit sold sepa- rately) AGENCY LISTINGS AND APPROVALS These listings and approvals apply to the devices specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL Listed: S2522 (FSB-200, FSB-2005) ULC Listed: S2522 (FSB-200A, FSB-200SA) CSFM: 7260-0028:228 MEA: 95-04-E Maryland State Fire Marshal: Permit #2167 FM Approved PRODUCT LINE INFORMATION FSB-200: Intelligent beam smoke detector FSB-200A: Same as FSB-200 with ULC Listing. FSB-2005: Intelligent beam smoke detector with integral sen- sitivity test. FSB-2005A: Same as FSB-200S with ULC Listing. BEAMLRK: Long range accessory kit (required for applica- tions in excess of 230 ft/70 m). BEAMMMK: Multi-mount kit (provides ceiling or wall mount capability with increased angular adjustment). BEAMSMK: Surface-mount kit. RTS151: Remote test station. RTS151A: Same RTS151 with ULC listing. RTS151KEV: Remote test station with key lock. RTS151KEYA: Same as the RTS151KEY with ULC listing. BEAMHK: Heating kit for use with the transmitter/receiver unit of FSB-2005. For prevention of condensation. BEAMHKR: Heating kit for use with the reflector on FSB-2005. For prevention of condensation 6500-MMK: Heavy-duty multi-mount kit for installations prone to vibration or where there is difficulty mounting the set angle. When installed with the transmitter/receiver unit, the 6500- SMK must be used as well. 6500-SMK: Surface-mount kit (required when using 6500- MMK to mount transmitter/receiver). Acclimate® PlusTM is a trademark of Honeywell International Inc. ©2009 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. I We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. M~~ All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6985:C • 11/16/09 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7260-0028:0228 Page 1 of 1 CATEGORY: 7260 -- SMOKE DETECTION SYSTEM-BEAM TYPE LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models FSB-200 and FSB-2005 projected beam smoke detector. Each unit consists of resistors, capacitors, diodes: photo diodes and LED, on a printed wiring board inside an enclosure that has an opening to the outside air. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 15-32VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as projected beam smoke detectors for use with Models BEAMMMK, BEAMSMK and BEAM LRK mounting kits (CSFM Listing No. 7300-1209:231) and separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. 06-16-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 19, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FST-951 Series Intelligent Thermal (Heat) Detectors DN-60975:A NOTIFIER® by Honeywell General The NOTIFIER FST-951 Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermal technologies make the FST-951 Series ideal for both system operation and build- ing design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F! 57°C fixed-temperature, rate-of-rise and a 180°F/880C fixed high- temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. Detectors are available for both FlashScan® and CLIP applications as desig- nated. Features Sleek and stylish contemporary design. Advanced thermal technology for fast response. Fixed temperature model (FST-951) factory preset to 135°F (57°C). Rate-of-rise model (FST-951R), 15°F (8.3°C) per minute. High temperature model (FST-951 H) factory preset to 190°F (88°C). Addressable by device. Compatible with FlashScan® and CLIP protocol systems. Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). Two-wire SLC connection. Visible LEDs blink" every time the unit is addressed. 3600-field viewing angle of the visual alarm indicators (two bi- color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. Integral communications and built-in device-type identification. Remote test feature from the panel. Built-in functional test switch activated by external magnet. Walk test with address display (an address of 121 will blink the detector LED 12-(pause)-1). Low standby current. Built-in tamper-resistant feature. Designed for direct-surface or electrical-box mounting. Sealed against back pressure. Plugs into separate base for ease of installation and mainte- nance. SEMS screws for wiring of the separate base. Optional remote, single-gang LED accessory. Optional sounder, relay, and isolator bases. FST-951 A in B300-6 Base Detector spacing: UL approved for 50 ft. (15.24 m) center to center. FM approved for 25 x 25 ft. (7.62 x 7.62 m) spacing. Relative humidity: 10% - 93% non-condensing. Thermal ratings: Fixed-temperature set point 57°C (135°F), rate-of- rise detection 8.3°C (15°F) per minute, high temperature heat 88°C (190°F). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 200uA @ 24 VDC (one communica- tion every 5 seconds with LED enabled). LED current (max.): 4.5mA @ 24 VDC ("ON"). Applications Use thermal detectors for protection of property. For further informa- tion, refer to 156-6522, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications. Installation The FST-951 Series plug-in intelligent thermal detectors use a sepa- rate base to simplify installation, service, and maintenance. Installa- tion instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see DN-60054. NOTE: 1) Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring 'T-taps" or branches are permitted for Style 4 (Class "B") wiring. 2) When using relay or sounder bases, consult the ISO-X(A) installation sheet 156-1380 for device limita- tions between isolator modules and isolator bases. Specifications Size: 2.0° (5.3 cm) high: base determines diameter. - B300-6: 6.1' (15.6 cm) diameter. - B501: 4° (10.2 cm) diameter. For a complete list of detector bases, see DN-60981 Shipping weight: 3.40z (96.4g) Operating temperature range: FST-951, FST-951R Series: -20°C to 38°C (-4°F to 100°F); FST-951 H Series: -20°C to 66°C (-4°F to 150°F). DN-60975:A • 4/23/18 - Page 1 of 3 Agency Listings and Approvals These listings and approvals apply to the detectors specified in this document.In some cases, certain detectors or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. UL/ULC Listing: S2101 FM Approved CSFM: 7270-0028:0502 Product Line Information NOTE: "A" suffix indicates ULC Listed model. NOTE: "-IV" suffix indicates FlashScanO and CLIP device. FST-951: White, low-profile intelligent 135°F fixed thermal sensor, FlashScan only. FST-951A: Same as FST-951 but with ULC listing. FST-951-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, FlashScan and CLIP. FST-951A-IV: Same as FST-951-IV but with ULC listing. FST-951R: White, low-profile intelligent rate-of-rise thermal sensor, FlashScan only. FST-951 RA: Same as FST-951 A but with ULC listing. FST-951 R-IV: Ivory, low-profile intelligent rate-of-rise fixed thermal sensor, FlashScan and CLIP. FST-951 RA-IV: Same as FST-951 R-IV but with ULC listing. FST-951H: White, low-profile intelligent 190°F fixed thermal sensor, FlashScan only. FST-951 HA: Same as FST-951 H but with ULC listing. FST-951H-IV: Ivory, low-profile intelligent 190°F thermal sensor, FlashScan and CLIP. FST-951 HA-IV: Same as FST-951 H-IV but with ULC listing. INTELLIGENT BASES NOTE: For details on intelligent bases, see DN-60981 B300-6: White, 6" base, standard flanged low-profile mounting base. B300-6-IV: lvory,6" base, standard flanged low-profile mounting base. B300A-6: Same as B300-6, ULC listed. B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B501-WHITE: White, 4" standard European flangeless mounting base. UL/ULC listed. B501-BL: Black, 4" standard European flangeless mounting base. UL/ULC listed. B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed. B501-WHITE-BP: Bulk pack of B501 -WHITE contains 10. B224RB-WH: White, relay base. B224RB-IV: Ivory, relay base. B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224B1-WH: White, isolator detector base. B224B1-IV: Ivory isolator detector base. B224B1A-WH: White, isolator detector base, ULC listing. B224B1A-IV: Ivory isolator detector base, ULC listing. 8200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz .i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +1- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz .i-/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B21OLP(A) base. TR300-IV: Ivory, replacement flange for B21OLP(A) base. RA100Z(A): Remote LED annunciator. 3 - 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501 (A) and B3006(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. DN-60975:A • 4/23/18 - Page 2 of 3 Notifier® and FlashScan® are registered trademarks of Honeywell International Inc. Notifier® and Bayblend® is a registered trademark of Bayer Corp. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IS09001 _ All specifications are subject to change without notice. :11 23= MGINEEIUNG & MRNEACIUIING QUALITY SYSTEMS For more information, contact Notifier. Phone: (800) 627-3473, FAX: (203) 484-7118. www.notifier.com Page 3 of 3— DN-60975:A • 4/23/18 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0028:0502 Page 1 of 1 CATEGORY: 7270-- HEAT DETECTOR LISTEE: NotifierOne Fire-Lite Place, Nlorthford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models FST-951, FST-951 H, NH-200, NH-200H (fixed temperature) and FST-951 R, NH-200R (fixed temperature with Rate-of-Rise) electronic heat detectors. Suffix -IV for ivory color and -BL for black color. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Models FST-951 and NH-200 (fixed temperature): 135°F. Models FST-951H and NH-200H (fixed temperature): 190°F. Models FST-951R, NH-200R (fixed temperature with rate of rise):135°F. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL label. APPROVAL: Listed as heat detectors for use with Notifier base B71OLP (CSFM No. 7300-0028:173); System Sensor bases B501, B21OLP, B300-6, B300-6-IS (CSFM No. 7300-1653:0109); B224B1, B224RB (CSFM No. 7300-1653:0126); B200S, B200SR (CSFM No. 7300-1653:0213); B200S-LF, B200SR-LF (CSFM No. 7300-1653:238); and separately listed compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev 02-14-18 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6720:E FMM.1 (A), FMM.1 01(A), FZM-1 (A) & FDM-1 (A) Monitor Modules with FlashScan© General Four different monitor modules are available for Notifier's intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-contact input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors (FZM-1 (A)). FMM-1(A) is a standard-sized module (typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input devices. FMM-101(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75" (6.985 cm) W x 0.65" (1.651 cm) D that supervises a Style B (Class B) circuit of dry-contact input devices. Its compact design allows the FMM-101(A) to be mounted in a single-gang box behind the device it monitors. FZM-1(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D (Class A) or Style B (Class B) circuit. FDM-1(A) is a standard-sized dual monitor module that mon- itors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (lDCs) at two separate, consecutive addresses in intelligent, two-wire systems. FlashScan® (U.S. Patent 5,539,389) is a communication protocol developed by NOTIFIER that greatly increases the speed of communication between analog intelligent devices. Intelligent devices communicate in a grouped fashion. If one of the devices within the group has new information, the panel CPU stops the group poll and concentrates on single points. The net effect is response speed greater than five times that of other communication protocols. FMM.1 (A) Monitor Module Built-in type identification automatically identifies this device as a monitor module to the control panel. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFl) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. LED flashes green during normal operation (programma- ble option) and latches on steady red to indicate alarm. The FMM-1(A) Monitor Module is intended for use in intelli- gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1(A) can be used to replace MMX-1(A) modules in existing systems. FMM-1(A) APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- NOTIFIER® by Honeywell FMM-1(A) (Type H) open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. FMM-1(A) OPERATION Each FMM-1(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FMM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.0 mA (LED on). Average operating current: 375 pA (LED flashing), 1 com- munication every 5 seconds, 47k EOL. Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. EOL resistance: 47K Ohms. Temperature range: 32°F to 120°F (0°C to 49°C). Humidity range: 10% to 93% noncondensing. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. DN-6720:E• 07/30/2015 - Page 1 of 4 FMM.1O1 (A) Mini Monitor Module Temperature range: 32°F to 120°F (0°C to 49°C). Built-in type identification automatically identifies this Humidity range: 10% to 93% noncondensing. UCVIUC 00 0 1110" 01 1110 U V LU LI IC JCI al. Powered directly by two-wire SLC loop. No additional power required. High noise (EMF/RFI) immunity. Tinned, stripped leads for ease of wiring. Direct-dial entry of address: 01 - 159 on FlashScan loops; 01 —99 on CLIP loops. 1415 0 1 ADDRESS 0 1 :E 12 1( 3 0~3 3 11 4 LOOP 109 I 8 76 8 76 I TENS ONES II II H I oU iluj jH Ii-.J LU 13 1(0 The FMM-101(A) Mini Monitor Module can be installed in a single-gang junction directly behind the monitored unit. Its small size and light weight allow it to be installed without rigid mounting. The FMM-101(A) is intended for use in intelligent, two-wire systems where the individual address of each mod- ule is selected using rotary switches. It provides a two-wire initiating device circuit for normally-open-contact fire alarm and security devices. The FMM-101(A) can be used to replace MMX-101(A) modules in existing systems. FMM-101(A) APPLICATIONS Use to monitor a single device or a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally-open dry-contact devices. May also be used to monitor normally-open supervisory devices with spe- cial supervisory indication at the control panel. Monitored cir- cuit/device is wired as an NFPA Style B (Class B) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. FMM-101(A) OPERATION Each FMM-101(A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). FMM-101(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Maximum IDC wiring resistance: 1500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 450 pA. EOL resistance: 47K Ohms. Dimensions: 1.3° (3.302 cm) high x 2.75" (6.985 cm) wide x 0.65" (1.651 cm) deep. Wire length: 6" (15.24 cm) minimum. FZM.1 (A) Interface Module Supports compatible two-wire smoke detectors. Supervises IDC wiring and connection of external power source. High noise (EMF/RFI) immunity. SEMS screws with clamping plates for ease of wiring. Direct-dial entry entry of address: 01 - 159 on FlashScan loops, 01 - 99 on CLIP loops. LED flashes during normal operation; this is a program- mable option. LED latches steady to indicate alarm on command from control panel. The FZM-1(A) Interface Module is intended for use in intelli- gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- wire conventional smoke detectors. It transmits the status (normal, open, or alarm) of one full zone of conventional detectors back to the control panel. All two-wire detectors being monitored must be UL compatible with the module. The FZM-1(A) can be used to replace MMX-2(A) modules in existing systems. FZM-1(A) APPLICATIONS Use the FZM-1(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA Style B (Class B) or Style D (Class A) Initiating Device Cir- cuit. A 3.9 K Ohm End-of-Line Resistor (provided) terminates the end of the Style B or D (class B or A) circuit (maximum IDC loop resistance is 25 Ohms). Install ELR across termi- nals 8 and 9 for Style D application. FZM-1(A) OPERATION Each FZM-1 (A) uses one of the available module addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status (open/normal/short) of its Initiating Device Circuit (IDC). A flashing LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to current limita- tions on the loop). FZM-1(A) SPECIFICATIONS Nominal operating voltage: 15 to 32 VDC. Maximum current draw: 5.1 mA (LED on). Maximum IDC wiring resistance: 25 Ohms. Average operating current: 270 pA, 1 communication and 1 LED flash every 5 seconds, 3.9k eol. EOL resistance: 3.9K Ohms. External supply voltage (between Terminals 110 and T11): DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum. Current: 90 mA per module maximum. Temperature range: 32°F to 120°F (0°C to 49°C). Page 2 of 4— DN-6720:E •07/30/2015 Humidity range: 10% to 93% noncondensing Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125 (5.398 cm) deep box. FDM.1 (A) Dual Monitor Module The FDM-1(A) Dual Monitor Module is intended for use in intelli- gent, two-wire systems. It provides two independent two-wire initiating device circuits (lDCs) at two separate, consecutive addresses. It is capable of monitoring normally open contact fire alarm and supervisory devices; or either normally open or nor- mally closed security devices. The module has a single panel- controlled LED. NOTE: The FDM-1(A) provides two Style B (Class B) IDC circuits ONLY Style D (Class A) IDC circuits are NOT supported in any application. FDM-1(A) SPECIFICATIONS Normal operating voltage range: 15 to 32 VDC. Maximum current draw: 6.4 mA (LED on). Average operating current: 750 pA (LED flashing) Maximum IDC wiring resistance: 1,500 Ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K Ohms. Temperature range: 32° to 120°F (0° to 49°C). Humidity range: 10% to 93% (non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125" (5.398 cm) deep box. FDM-1(A) AUTOMATIC ADDRESSING The FDM-1(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the FDM-1 (A) is set to address "26", then it will automatically assign itself to addresses "26" and "27". NOTE: "Ones" addresses on the FDM-1(A) are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation FMM-1(A), FZM-1(A), and FDM-1(A) modules mount directly to a standard 4" (10.16 cm) square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances, and regula- tions. These modules are intended for power-limited wiring only. The FMM-101(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances, and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. UL: S635. ULC: S635. FM Approved. CSFM: 7300-0028:0219, 7165-0028:0224, 7165-0028:0243. MEA: 457-99-E. U.S. Coast Guard: 161.002/50/0 (NFS2-640, NFS2-320, NFS2-3030). Lloyd's Register: 11/600013 (NFS2-640, NFS2-320, NFS2-3030). Fire Dept. of New York: COA #6121 (NFS2-640, NFS- 320), COA# 6114 (NFS2-3030). Product Line Information NOTE: "A" suffix indicates ULC-listed model. FMM-1(A): Monitor module. FMM-101(A): Monitor module, miniature. FZM-1(A): Monitor module, two-wire detectors. FDM-1(A): Monitor module, dual, two independent Class B circuits. SMB500: Optional surface-mount backbox. NOTE: See installation instructions and refer to the SLC Wiring Manual, PN 51253. DN-6720:E• 07/30/2015 - Page 3 014 FlashScan® and NOTIFIER® are registered trademarks and FireWatchT is a trademark of Honeywell International Inc. @2015 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. I so 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. • We cannot ccver all specific applications or anticipate all requirements. QUALITY SYSTEMS All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Page 4 of 4— DN-6720:E 07/3012015 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL LISTING SERVICE FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM (§ LISTING No. 7300-0028:0219 Page 1 of 1 CATEGORY: 7300 --FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennetthoneywell.com DESIGN: Models XP6-R relay module, XP6-C, supervising control module, XP10-M input monitor module, XP6-MA six zone interface module, FMM-1, FMM-101, FZM-1, FSM-101, FDM-1, FTM-1 monitor modules, FCM-1, FRM-1 control modules, and *FDRM.1 with 2 input/2 output relay module. All devices are intended to be connected between the signaling line circuit of a compatible fire alarm control panel. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 16-33 VDC Primary INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number and UL label. APPROVAL: Listed as control unit accessories for use with listee's separately listed compatible fire alarm control units. Model FTM-1 is intended to be used with Notifier Models NFS-640, NFS2-640 (CSFM Listing No. 7165-0028:214), NFS-3030, NFS2-3030 (CSFM Listing No. 7165-0028:224) Fire Alarm Control Units. NOTE: If an external power supply is used for Model XP6-MA, the negative of the external power supply is referenced to the negative of the auxiliary supply of the compatible control panel. This is done in order to detect ground faults on the initiating circuit. *Rev. 10-24-11 mt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division DN-6726:D • H-240 NBG-I2LX Addressable Manual Pull Station General The Notifier NBG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interlace for any Notifier intelligent control panel except FireWarden series panels, and the NSP- 25 panel. Because the NBG-12LX is addressable, the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features Maintenance personnel can open station for inspection and address setting without causing an alarm condition. Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. Handle latches in down position and the word "ACTIVATED" appears to clearly indicate the station has been operated. Captive screw terminals wire-ready for easy connection to SLC loop (accepts up to 12 AWG/3.25 mm2 wire). Can be surface mounted (with SB-10 or S3-1/0) or semi- flush mounted. Semi-flush mount to a standard single- gang, double-gang, or 4" (10.16 cm) square electrical box. Smooth dual-action design. Meets ADAAG controls and operating mechanisms guide- lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. Highly visible. Attractive shape and textured finish. Key reset. Includes Braille text on station handle. Optional trim ring (BG12TR). Meets UL 38, Standard for Manually Actuated Signaling Boxes. Up to 99 NBG-12LX stations per loop on CLIP protocol loops. Up to 159 NBG-12LX stations per loop on FlashScan® pro- tocol loops. Dual-color LED blinks green to indicate normal on FlashScan® systems. Construction Shell, door, and handle are molded of durable polycarbonate material with a textured finish. Specifications Shipping Weight: 9.6 oz. (272.15 g) Normal operating voltage: 24 VDC. Maximum SLC loop voltage: 28.0 VDC. Maximum SLC standby current: 375 pA. Maximum SLC alarm current: 5 mA. Temperature Range: 32°F to 120°F (0°C to 49°C) Relative Humidity: 10% to 93% (noncondensing) For use indoors in a dry location @NOTIFIER® by Honeywell The NBG-12LX Addressable Manual Pull Station Installation The NBG-12LX will mount semi-flush into a single-gang, dou- ble-gang, or standard 4" (10.16 cm) square electrical outlet box, or will surface mount to the model SB-10 or SB-I/O sur- face backbox. If the NBG-12LX is being semi-flush mounted, then the optional trim ring (BG12TR) may be used. The BG12TR is usually needed for semi-flush mounting with 4" (10.16 cm) or double-gang boxes (not with single-gang boxes). Operation Pushing in, then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word "ACTI- VATED" (in bright yellow) appears at the top of the handle, while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the key and pull the door open. This action resets the handle; clos- ing the door automatically resets the switch. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual switch. Two rotary decimal switches allow address settings (1 —159 on FlashScan® systems, 1 —99 on CLIP systems). Architectural/Engineering Specifications Manual Fire Alarm Stations shall be non-coded, with a key- operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key. An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red-colored polycarbonate material with clearly visible operat- ing instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-b 0 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or DN-6726:D.4/13/2012—Page 1 of 2 4" (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel, send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. The loop poll LED shall be clearly visible through the front of the station. The LED shall flash while in the normal condition, and stay steadily illuminated when in alarm. Product Line Information NBG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) NBG-12LXSP: Spanish/English labelled version. NBG-12LXP: Portuguese labelled version. SB-10: Surface backbox; metal. SB-I/O: Surface backbox; plastic. BG12TR: Optional trim ring. 17021: Keys, set of two. NY-Plate: New York City trim plate. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). MEA: 67-02-E. CSFM: 7150-0028:0199. FDNY: COA #6085 (NFS2-640), COA #6098 (NFS2-3030). BSMI: C1313066760047. U.S. Coast Guard. Lloyd's Register. FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER® and FlashScan® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IF*11111 IMNIMC1IRINC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Notifier. Phone: (203) 484-7161, FA)(: (203) 484-7118. www.notifier.com Page 2 of 2— DN-6726:D • 4/13/2012 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL r-1fkT FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0028:0199 Page 1 of 1 CATEGORY: 7150-- FIRE ALARM PULL BOXES LISTEE: NotifierOne Fire-Lite Place, Northford, CT 06472-1653 Contact: Pete Sennett (203) 484-6127 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Models NBG-12, NBG-12S, NBG-12LR, NBG-12LRA, NBG-12LAO, NBG-12LAOB, NBG-1 2-LO, NBG-1 2LOB, NBG-1 2W, NBG-12LW, NBG-1 2NC, NBG-1 2WP, NBG-1 2LWP, NBG-1 2L, NBG-1 2LX, NBG-1 2LA, NBG-1 2PS, NBG-12LSP, NBG-1 2LPS, NBG-1 2LPSP, NBG-125P, NOT-BG12LX, NBG-12LXSP, NBG-12LXBL and NBG-12LXP fire alarm pull boxes. All units except Model NBG-12S are dual action pull stations. Models NBG-12LR and NBG-I2LRA are intended for agent releasing device. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models NBG-I2WP, NBG-I2LW, NBG-12W, NBG-12LWP, NBG-12LAO, NBG-12L0, NBG-I2LAOB and NBG-12L0B are intended for outdoor use when installed with Models WBB, SB-I/O, or WP-10 back box. Refer to listee's Installation Instruction Manual for details. These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments which the controls and operating mechanisms required to be operable at no more than 51bs. force with one hand and shall not require tight grasping, pinching, or twisting of the wrist. *Corrected 10-08-12 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct Rv' operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division F E .1. to" ~-L Sys tpem 'F SYSTEM $ SENSOR® Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications SpectrAlert Advance audible visible notification products are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall units Mounting plate shorting spring checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert devices Compatible with MDL3 sync module Listed for ceiling or wall mounting The SpectrAlert Advance series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry. With white and red plastic housings, wall and ceiling mounting options, and plain and FIRE-printed devices, SpectrAlert Advance can meet virtually any application requirement. Like the entire SpectrAlert Advance product line, wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, SpectrAlert Advance utilizes a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with three volume selections. Agency Listings SIGNALING ®MEAA LISTED APPROVED approved 7125-1653:186 (indoor strobes) 7125-1653:188 (horn strobes, 04011 (chimes, horn strobes, horns) 3023572 MEA452-05-E chime strobes) S5512 (strobes) 7135-1653:169 (horns, chimes) SpectrAlert Advance Specifications General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync.Circuit°° Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 ard 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full- wave rectified unfiltered power supply. Strobes and hcrn strobes shall have field-selectable candela settings including 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model ______ listed to UL 1971 and shall be approved for fire protective service The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/16 x 411/16 x 21/8-inch back box. The module shall also control two Style V (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12to18AWG Wall-Mount Dimensions (including lens) 5.6"L x 4.7-W x 2.5'D (142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm Lx 119 mm W x 33 mm D) Wall-MountTrim Ring Dimensions (sold as a5 pack) (TR-HS) 5.7"L x 4.8"W x 0.35"D (145 mm Lx 122 mm W x 9 m D) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P, 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd. UL Current Draw Data UIL Max. Strobe Current Draw (mA RMS) tuJu:ti€rn7 Y1;1iFi 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-temporal High 57 56 69 75 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 UL Max. Current Draw (mA RMSf, Z-W~ire -146-m- Stro-6e,-ttandard Candela Range (15-115 cd) 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 ,UL Max. Current Draw (mAAMSY,270n~Kd 'Stro"gjh,Candela Range (135-185 cd) 1, 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Horn and Horn Strobe Output (dBA) 8-17.5 16-33 24-Volt Nominal Switch Volts Volts Reverberant Anechoic Position Sound Pattern dB DC FWR DC FWR DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 75 75 80 80 86 86 96 96 3 Temporal Low 71 71 76 76 83 80 94 89 4 Non-Temporal High 82 82 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 73 74 81 81 88 84 96 92 Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 78 85 85 90 90 97 98 9t Coded Low 74 75 81 81 88 85 96 92 tSettings 7, 8, and 9 are not available on 2-wire horn strobes SpectrAlert Advance Dimensions di Wall-mount horn strobes SpectrAlert Advance Ordering Information -.- Wall Horn Strobes Wall Strobes (cont.) P2R 2-Wire Horn Strobe, Standard cd, Red SRH Strobe, High cd, Red; P2R-P 2-Wire Horn Strobe, Standard cd, Red, Plain SRH-P Strobe, High cd, Red, Plain P2R-SP 2-Wire Horn Strobe, Standard cd, Red, "FUEGO" SRH-SP Strobe, High cd, Red, "FUEGO" P2RH 2-Wire Horn Strobe, High cd, Red SW Strobe, Standard cd, White P2RH-P 2-Wire Horn Strobe, High cd, Red, Plain SW-P Strobe, Standard cd, White, Plain P2W 2-Wire Horn Strobe, Standard cd, White SWH Strobe, High cd, White P2W-P 2-Wire Horn Strobe, Standard cd, White, Plain SWH-P Strobe, High cd, White, Plain P2WH 2-Wire Horn Strobe, High cd, White Horns P2WH-P 2-Wire Horn Strobe, High cd, White, Plain HR Horn, Red P4R 4-Wire Horn Strobe, Standard cd, Red HW Horn, White P4R-P 4-Wire Horn Strobe, Standard cd, Red, Plain Accessories P4RH 4-Wire Horn Strobe, High cd, Red TR-HS Trim Ring, Wall, Red P4W 4-Wire Horn Strobe, Standard cd, White SBBR Indoor Surface Mount Back Box, Red Wall Strobes SBBW Indoor Surface Mount Back Box, White SR Strobe, Standard cd, Red SR-P Strobe, Standard cd, Red, Plain SR-SP Strobe, Standard cd, Red, "FUEGO" Notes: All -P models have a plain housing (no FIRE' marking on cover) All -SP models have "FUEGO" marking on cover "Standard cd" refers to strobes that include 15, 15/75, 30, 75, 95, 110, and 115 candela settings. "High cd" refers to strobes that include 135, 150, 177, and 185 candela settings. rlV$7j7 3825 Ohio Avenue • St. Charles, IL 60174 1S for SENSOR' Phone: 800-SENSOR2 • Fax: @2014 System Sensor 630-377-6495 Product specificationt sublect to change without notice. V;Sit systerrnsensor,cnm Current product information, including the latest version ot this data sheet. www.systemsensor.com AVDS10201 • 1/14 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL _____ FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:0188 Page 1 of 1 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Pete Sennett (630) 762-5362 Fax (203) 484-7309 Email: pete.sennett@honeywell.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH Horn/Strobes* four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix 'P' for plain housing with no lettering. "K" suffix models are suitable for outdoor applications at temperatures from -40°F to +151°F (-40°C to +66°C) and are rated NEMA 4X when used with the System Sensor weather proof back boxes models SA-WBB (Wall), SA-WBBW (Wall), SA-WBBC (Ceiling) and *SA..t/BCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8 - 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as *horn/strobes or chime/strobes suitable for signaling appliances and equipment for the hearing impaired applications when used with separately listed compatible fire alarm control units. Horn/strobes with -K suffix are suitable for indoor or outdoor use, ceiling or wall mount. Chime section is suitable for private mode and indoor use only. Horn/Strobes or chime/strobes* can generate the distinctive three-pulse audible Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2010 Edition. Refer to listee's Installation Instruction Manual for details. "corrected 12-15-11 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division