HomeMy WebLinkAbout6161 EL CAMINO REAL; ; FPC2018-0359; PermitPERMIT REPORT k-city of Carlsbad CARLSBAD, CA 92009-1602 Work Class: Fire Sprinklers Track #: Lot #: Project #: Plan #: Construction Type: Orig. Plan Check #: Plan Check #: Permit No: FPC2018-0359 Status: Closed - Finaled Applied: 11/01/2018 Issued: 11/20/2018 Finaled Close Out: 03/07/2019 Inspector: Final Inspection: Print Date: 02/17/2022 Job Address: 6161 EL CAMINO REAL, # BLDG 2, Permit Type: FIRE-Construction Commercial Parcel #: 2131002400 Valuation: $80,369.28 Occupancy Group: #of Dwelling Units: Bedrooms: Bathrooms: Project Title: Description: VIASAT BLDG 2 PHASE 3 DAY 2 - RELOCATE/ADD SPRINKLER PROTECTION (38 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 FIRE Reinspection (per inspection) $193.00 Total Fees: $746.00 Total Payments To Date: $746.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov OITA14 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18503 ViaSat Bldg. 2 - Day 2 6161 El Camino Real Carlsbad, CA 92009 FPC20I8-0359 6161 EL CAMINO REAL #BLD VIASAT BLDG 2 PHASE 3 DAY 2- RELOCATE/ADD SPRINKLER PROTECTION (38 HEADS) 2131002400 11/1/2018 FPC20I8-0359 UBMII IALSHEET EXISTING FEATURES Sizes: U 21/2" U 3" U 8" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gprn meter (standard) U - with cu ft/min meter Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) AW.NA Compliant C510 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM® Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM A126 Class B Coatings FDA Approved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Gate valve tamper switch (OSY-40) B A DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES VALVES VALVES OPEN VALVES in. mm I in. I mm in. mm in. mm in. I mm in. I mm in. mm in. mm lbs. I kg lbs. I kg 21/2 65 371/8 943 22 559 4 102 10 I 254 163/8 416 137/8 352 4 1102 101 I 45.9 211 I 95.8 3 I 80 381/8 968 22 559 4 1102 10 I 254 18 7/8 479 155/8 397 4 1102 101 I 45.9 231 1104.9 8 1200 711/81 1807 48 1219 71/21191 16 I 406 373/41 959 291/4 743 71/21191 847 1384.5 13231600.6 10 250 841/8 2137 58 1473 9 229 18 I 457 453/41 1162 353/8 899 9 229 14101640.1 222811011.5 FLOW CHARACTERISTICS MODEL 950DA 2 1/2" & 3" (STANDARD & METRIC) FLOW RATES (Its) 12.6 25.2 37.9 50.5 104 Co 69 cO 35 200 400 600 800 FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Its) 63.1 126.2 189.3 252.4 04 cc 0. 0 1000 2000 3000 FLOW RATES (GPM) Rated Flow (Established by approval agencies) 39 In 35 Uj 4000 TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12(305mm) and a maximum of 30' (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. PROTECTIVE ENCLOSURE Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 3' 115 173 230 346 4" 198 298 397 595 6' 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 1 2458 3687 I 12 MIN. 30 MAX. SUPPORT DIRECTION OF FLOW MAIN INLET CD OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM Al 26 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 950DA. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com FireLock® V34, K11.2 Ltauicr Models V3411 Standard Response, V3412 Quick Response 40.30 Extended Coverage/Light Hazard (ECLH) Pendent and Recessed Pendent twh V3411/V3412 V3411/V3412 Pendent Recessed Pendent 1.0 PRODUCT DESCRIPTION Models: V3411, V3412 Style: Extended Coverage! Light Hazard - Pendent, Recessed Pendent Nominal Orifice Size: /8716 mm K Factor: 11.2 Imp./16.2 SI.' Nominal Thread Size: 3/4 N P1/20 mm BSPT Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi!48kPa Temperature Rating: See chart QD Coverage: Extended spray coverage is up to 400 square feet (37.2 sq. m) per NFPA 13 and FM Data Sheet 2-0. 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. 2.0 CERTIFICATION/LISTINGS c® i USliD ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. p System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 40.30 2552 Rev G updated 03/2017 © 2017 Victaulic company. All rights reserved. 1 ictauliC victaulic.com 2.0 CERTIFICATION/LISTINGS (Continued) APPROVALS/LISTINGS Model V3411 V3411 V3411 V3412 V3412 V3412 Orifice Size (inches) ~ 5/a" 5/a" s/a" 5/ % Orifice Size (mm) 16 16 16 16 16 16 Nominal K Factor Imperial 11.2 11.2 11.2 11.2 11.2 11.2 Nominal K Factor SI.2 16.2 16.2 16.2 16.2 16.2 16.2 Response Standard Standard Standard Quick Quick Quick Deflector Type Pendent Recessed Pendent Up to ½" Adjustment Recessed Pendent Up to 1/4" Adjustment Pendent Recessed Pendent Up to ½" Adjustment Recessed Pendent Up to Ajustment Room Size Feet/meters Approved Temperature Ratings F°/C° 34 cULus A A A A A A 16X16 FM B C - C D - 4.9 X 4.9 NYC/MEA5 A A A A A A CSFM6 A A A A A A cULus A A A A A A 18X18 FM B C - C D - 5.5 X 55 NYC/MEA5 A A A A A A CSFM6 A A A A A A cULus A A A A A A 20X20 FM B C - C D - 6.1 X 6.1 NYC/MEA5 A A A A A A CSFM6 A A A A A A 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. Listings and approval as of printing. Not all temperature rating combinations are Approved or Listed. Check Victaulic for specific combinations. Light hazard only. MEA #62-99-E 6 CSFM #7690-0531:112 Temperature Rating A - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C) B - 135°F(57°C), 155°F (68°C), 175°F (79°C) C - 135°F (57°C), 155°F (68°C) D— 135°F (57°C) 40.30 2552 Rev G Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulitnm JtGIuIiC• 3.0 SPECIFICATIONS - MATERIAL Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon7 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 3.1 SPECIFICATIONS - ACCESSORIES Installation Wrench: El Open End: V34 O Recessed: V34 Sprinkler Finishes: Plain Brass El Chrome Plated El White Painted8 Custom Painted8 VC-2509 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 4.0 DIMENSIONS 21/2 / 64 mm 13/4"! 45 mm -. 35 mm Standard Pendent - V3411, V3412 40.30 2552 Rev G Updated 03/2017 © 2017 Victaulic company. All rights reserved. victaulic.com 3 ___________ 4.1 INSTALLATION DIMENSIONS Ys" (60mm) Max. Hole 2 (51 mm) Mm. Hole - 11/16" ye (29 ram) (18mm) (16mm) Typical Ceiling Tile 13/8-1 _ 4 Finished Surface (34 m (47 mm) m) MAXIMUM RECESS 25/Io" (75 mm) MAXIMUM EXTENSION ½" Adjustment Recessed - V3411, V3412 (drawings not to scale) (24 Mm. Hole mm) Typical Ceiling Tile (16 mm) _ $ _ l/8' Finished Surface (47 mm) MAXIMUM RECESS 26/16"" )75 mm) MAXIMUM EXTENSION 3/4" Adjustment Recessed - V3411, V3412 (drawings not to scale) (35 mm) -4 )29 mm) 40.30 2552 Rev 0 Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 4 ictaulilce victaulic.com 5.0 PERFORMANCE Room Size Sprinkler Performance Flow And Pressure (Minimum) V3411, V3412 Room Size Flow Rate End Sprinkler Pressure GPML/LPM PSI/kPa Ft. x Ft. FM UL FM UL m x m 16X16 30 30 7 7 4.9X4.9 115 115 50 50 18X18 33 33 9 9 5.5X5.5 125 125 60 60 20X20 40 40 13 13 6.1X6.1 150 150 90 90 Miniumum Installation Spacing Feet/meters Response UL FM V3411 -Standard 10.0 3.0 no criteria V3412 - Quick 8.0 10.0 2.4 3.0 6.0 NOTIFICATIONS A WARNING I Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. 40.30 2552 Rev 0 Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com 5 %J'tauIic victaulic.com 7.0 REFERENCE MATERIALS Ratings All glass bulbs are rated for temperatures from -65°F (-54°C) up to those shown in adjacent table. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green Available Wrenches Open End Recessed Pendent V34 V34 Recessed Pendent - V34 1-40: FireLockTM Automatic Sprinklers Installation Manual T13-901: Corrosion Resistant Sprinklers Technical Data 40.88: FireLackTM Sprinkler Escutcheons User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer, Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, prodect, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our weboite at www.vicfaolic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 40.30 2552 Rev 0 Updated 03/2017 0 2017 Victaulic Company. All rights reserved. victaulic.com N. \Ltaulic FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: j4tauIic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 S.1.1 Nominal Thread Size: ½" NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart 1 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I41719 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. ii Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock'5 I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 © 2014 victaulic company. All rights reserved. 1 Ataulic - victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Material Specifications: Accessories Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: F-1 Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated White painted3 El Black painted3 El Custom painted3 Proprietary Nickel Teflon2 coating3 El VC-250 155, 200, 286 SR Only: LII Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 2 \1'tauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/2" 1/2" /2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal 1< Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor SI.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type upright Pendent Recessed upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C cuLus 1750F/790C 1750F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 175°F/79°C 2860F/1410C 286°F/141*C 286°F/141°C 286°F/1410C 286°F/141°C 200°F/93°C 360°F/1820C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/680C 1350F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 1750F/790C 175°F/790C 155°F/68°C 1550F/68°C 1550F/680C 155°F/68°C FM 200°F/930C 200°F/93°C 175°F/791C 1750F/790C 1750F/790C 175°F/79°C 2860F/1410C 286'F/1410C 200°F/930C 200°F/93°C 200°F/93°C 200°F/93°C 360°F/1820C 360°F/1820C 286°F/141°C 286°F/141°C 135°F/570C 135°F/570C 135°F/570C 1350F/57°C 135°F/57°C 1550F/680C 155°F/680C 155°F/68°C 155°F/680C 1550F/68°C 135°F/57°C NYC/MEA 62-99-E 1750F/790C 1750F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/79°C 2860F/141'C 286°F/141 °C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 360'F/1 820C 360°F/1820C 286°F/141 °C 2860F/1410C 286°F/1410C 1350F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/570C 135°F/570C 135°F/57°C 135°F/57°C 175°F/79°C 175°F/79°C 155°F/68°C 1550F/68°C 155°F/680C 155°F/68°C CSFM 7690-0531:112 200°F/93°C 200°F/93°C 175°F/790C 175°F/79°C 175°F/79°C 175°F/79°C 286°F/141 °C 286°F/141 °C 200°F/930C 200°F/93°C 200°F/930C 200°F/93°C 360°F/1 82°C 360°F/182°C 286°F/1 41 °C 2860F/1410C 2860F/1410C 135°F/57°C 155°F/68°C 135°F/57°C LPCB 175°F/79°C None None 1550F/68°C None None 200°F/93°C 175°F/79°C 286'F/1 410C 200°F/930C 360°F/1 82°C 135°F/570C 1350F/570C 135°F/570C 1350F/57°C 155°F/68°C 1550F/680C 1350F/57°C 155°F/680C 1550F/680C 135°F/57°C VNIIPO 175°F/79°C 175°F/79°C 155°F/68°C 1750F/79°C 175°F/79°C 1550F/68°C 200°F/93°C 200°F/93°C 175°F/790C 200°F/930C 200°F/93°C 175°F/79°C 286°F/141 °C 286°F/141 °C 200°F/930C 286°F/141°C 2860F/141°C 200°F/93°C 360°F/1 82°C 360°F/1 82°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 1550F/680C 1550F/680C None 1550F/680C 1550F/68°C None 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286°F/141°C 2860F/141°C 360°F/1 82°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/790C None None 1750F/79°C None None 200°F/93°C 200°F/93°C 2860F/1410C 2860F/141°C 360°F/1820C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with 1/2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 02014 Victaulic company. All rights reserved. victaulic.com 3 jiItauIice victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: r7 21/8 60 mm 1 /8/ I 41 mm 60 Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2/51 mm Mm. Hole 17 Typical Ceiling Tile 30 mm I"A6'/ Finished Surface 37m 7 MAXIMUM RECESS 75 mm MAXIMUM EXTENSION ½ Adjustment Recessed - V2707, V2708 (drawing not to scale) 2W/sO mm F-- Max. Hole 2"/5l mm 18mm 37 mm Mm Hole I l/ 24 mm Typical Ceiling Tile Finished Surface 24 mm MAXIMUM RECESS - 75 mm MAXIMUM EXTENSION 3/4 Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 4 j4'tauiic 0 victaulic.com I Sprinklers I FireLockw I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent lx om 8: 4, 1,2m 2' 0.6m 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa 2' 4 8: 8' 15' 12' 14' O.6m 1. 2.1 1.8m 2.4m 3.0,, 3.7m 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory IIIIIIILIti1I 2' 4' 6 8' IV 12' 14 16 0.6m 1.2n 1.8m 2.4m 3.Om 3.7n 4.3m 49m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Au:hority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines coulc adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 JtauIicr 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F 8/107 C Blue Extra High K 360 F/182 C 300 Ff149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent / / V2707, V2708 Recessed Pendent V2703, V2704 upright - / 11 A WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. It LIM OWN Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our weboite at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 6 \J'tauIic Bull Moose Tube's Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVE) ONFSA (!III FPA' 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. SIZE (IN) (IN) I.D. (IN) CRR** WEIGHT/FT WATER FILLED WEIGHT BUNDLE SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 991 1.81 lbs/ft 2,518 61 1-1/2 1.900 1.682 7.76 209 lbs/ft 3.053 61 2 2.375 2.157 627 264 lbs/ft 4.223 37 2-1/2 2.875 2.635 492 3.53 lbs/ft 5.893 30 3 3.500 3.260 ' 354 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 1-1/4 1.660 1.380 1.00 227 lbs/ft 2.918 51 1-1/2 1.900 1.610 .1 .00 272 lbs/ft 3.602 44 2 2375 2.067 100 3.66 lbs/ft 5.114 30 2-1/2* 2.875 2.468 1.00 580 lbs/ft 7.875 30 3* 3.500 3.068 1.00 7.58 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10:80 lb/ft 16.316 19 'Only available in Cana Grande, AZ -Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA cans Grande, AZ Dallas, TX Masurt OH 63017 Dull Moose Tube's Eddythread 40® ADVANTAGES OF BULL MOOSE TUBP EDDYTHREAD 40® U is a lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM A135 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. EDDYTHREAD 40 SPECIFICATIONS c®us LISTED NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR LB/FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 *Corrosion Resistance Ratio per latest UI Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grand AZ Dallas TX Masury, OH 63017 (;] 4A NFPA 5 BuD Moose Tube's® EddyliteO is a lightwall threadable pipe manufactured in NPS 1 "through 2". Eddylit&° is truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylitee is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPR0V (;]4 ( N FPA' 6 ADVANTAGES OF BULL MOOSE TUBEa EODVLITE Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. 'Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 10! CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1.315 1.137 0.13 7.47 1.260 1.700 91 1-1/4 1.660 1.482 0.08 4.79 1.617 2.364 61 1-1/2 1.900 1:712 0.12 4.53 1.967 2.965 61 2 2.375 2.177 .: 0.16 ' 4.31 2.617 4.230 37 'Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com ('2 Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa Grandty AZ Dallas, TX Masuty, OH 63017 Dull Moose Tube's® Eddy Flow® ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® U is a specially engineered Certified to ASTM Al 35 and A795 Type E, Grade A. replacement for Schedule 10, FM approved for roll grooving and welding for use in wet systems. offering better flow characteristics UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type while providing design flexibility, sprinkler systems. This product is FM approved, as well Lightweight - saves shipping costs and offers easier handling. as UL Listed (for U.S. and Canada) Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. for roll grooving and welding. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. As an added benefit, it is more Supplied with EDDY GUARD Il® MlC preventative coating. economical to use than Schedule 10 due to reduced delivery costs ' and ease of handling. Furthermore, NPS O.D. EDDY FLOW® EDDY FLOW® WEIGHT WATER FILLED BUNDLE Eddy Flow's® larger ID provides SIZE (IN) (IN) (ID) CRR* PER FL WE SIZE an opportunity for downsizing and further cost savings. 1-1/4 1.660 1.530 1.98 1.222 2.019 61 1-1/2 1.900 1.728 3.44 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 *Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. c®us LISTED APPROVRJ I@ A.='. oiffim NFPA Q ® For Additional Information Contact (800)325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 saIes@bullmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA (sea Grand AZ Dalia TX Masuty, OH 63017 7 Dull Moose Tube's' Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I.) a versatile product that can be • Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with • FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. • UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. 'With a larger ID than other products on the market today, Ultra Eddy®offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM's requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY' WEIGHT WATER BUNDLE (IN) (IN) EDDY' (ID) CRR PER FT. FILLED WI. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 2.261 1.00 1.604 3.344 37 Pressfit is a Registered Trademark of Victauflc Company of America ** Corrosion Resistance Ratio per latest UI Directory listing c®us LISTED APPROM 14m] ONM NFPA 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation, In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas TX Masory, OH 63017 9 1 O.D.(in) 1.315 1.660 1.900 2.375 l.D.(in) 1.137 1482 1.712 2.177 EDDYLITEO Empty Weight (lb/ft) 1.260 1.617 1.967 2.617 Water-filled Weight (lb/ft) 1.700 2.364 2.965 4.230 C.R.R.013 OD(in) 1.295 008 1.650 012 1.900 016 2.375 I I lD(in) 1.083 1.418 1.645 2.123 EDDYTHREAD I .EmptyWeightQb/ft) 1.461 2.070 2.547 3.308 I Water-Filled Weight (lb/It) 1.860 2.754 3.468 4.842 [ (HR. O.D.(in) 1.00 1 315 1.00 1.660 1.00 1.900 1.00 2.375 2.875 3.500 4.500 I LD.(ln) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE C Empty Weight (lb/fl) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 I Water-Filled Weight (lbfft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 A For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road U Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas IX Masur3t OH 63017 c®us LISTED IiPPROVHJ ONFM L NFPA NPS(IN) 1 1-114 1-1/2 2 2-1/2 3 4 00(i) 1.315 1.660 1.900 2.375 I;D.(in) 1.201 1.546 1.786 2.261 ULTRA EDDY*EmptyWeight(lb/ft) 0.868 1.107 1.274 1.604 Pater-Filled Weight Pb/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 CO (in) 1.660 1.900 2.375 2.875 3.500 4.500 IC(in) 1.530 1.728 2.203 2.705 3.334 4.310 Empty Weight (lb/h) 1.222 -1.844 2.330 2.809 3.361 4.968 EDDY FLOW- Water-Filled Weight {lb/ft) 2.019 2.860 3.982 - 5.299 7.144 11.290 (HR 198 344 278 166 100 100 iO.a(mn) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 --(D. 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE EmptyweightOb/fl) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 10 hWter-lledWeight(1b/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 (RH. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE c®us LISTED /IPPRQVth [; I4A NFPA' 10 ULTRA EDDYO 0.868 91 1,659 1,896 1,975 SCHEDULE10 1.410 91 2,695 3,079 3,208 1 EDDYLITE' 1.260 91 2,408 2,752 2,867 EDDYTHREAD4On' 1.461 70 2,148 2,454 2,557 SCHEDULE 46 ' 1.680 70 2,470 2,822 2,940 LIMA EDDY 1.107 61 1,418 1,621 1,688 EDDY FLOW' 1.222 61 1,565 1,789 1,864 SCHEDULE 10 - :! EDDYLITE' 1.810 61 2,319 2,650 2,760 11/4 1.617 61 2,071 2,367 2,466 EDDYTHREAD4O' 2.070 51 2,217 2,534 2.639 SCHEDULE 40 2270 51 2431 2778 2,894 ULTRA EDDY 1 1.274 61 1,632 1,865 1,943 EDDY FLOW' 1.844 61 2,362 2.700 2,812 SCHEDULE 10 2.090 61 2,677 3,060 3,187 11 /2 EDDYLITE' 1.967 61 2,520 2,880 3,000 EDDYTHREAD40 2.547 44 2,353 2,690 2,802 SCHEDULE 40 2.720 44 2.513 2.872 2,992 - -- ULTRA EDDY' 1.604 37 1,246 1,424 1,484 EDDY FLOW' J 2.330 37 1 810 2,069 2,155 SCHEDULE10 ' 2.640 37 2,051 2,344 2,442 2 EDDYLITE' ' 2.617 37 2033 2,324 2,421 EDDYTHREAD40' 3.308 30 2,084 2,382 2,481 I SCHEOULE4O 3.660 30 2,306 2,635 2,745 EDDY FLOW' 2.809 1,770 2,022 2,107 2-1/2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 J SCHEDULE40 5.800 3,654 4,176 4.350 iL 3.361 1,341 1,533 1,596 3 SCHEDULE 10 4.340 19 1,732 1,979 2,062 -- SCHEDULE40 7.580 3024 3,456 3,601 1 EDDY FLOW' 4.968 1,982 2,265 2,360 4 SCHEDULE1O 5620 19 2,242 2,563 2,670 - SCHEDULE40 10.800 4,309 4,925 5,130 6i SCHEDULE 10 , 9.289 10 1,951 2,229 2,322 8 SCHEDULE 10 16.940 7 2,490 2,846 2,965 * Only Available in Casa Grande. AZ. Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 1 2.50 1 2.75 3.00 11/4 136 1 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 11/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 40 40 40 38 34 31 28 27 25 24 23 22 2 1/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1544 1235 1 1012 1 867 1 726 1 40 1 40 40 40 40 1 37 1 34 1 32 30 29 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings Max Zone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. F25 ft. 30 ft. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 119 L250 312 205 175 147 40 40 40 37 33 30 28 26 25 23 22 339 291 243 40 40 40 21 518 40 36 33 30 29 27 26 24 23 BULL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED APPROVED C;] 4 )N NFPA' •- For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ DallasX Masury, OH 63017 11 Mechanical-I® STYLES 920 AND 920N STYLES 920 AND 920N STYLE 920 CROSS PATENTED Victaulic MechanicalT® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a °holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-I outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HOPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap 110 hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-T unit. See page 8 for further information. MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPOM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade "I" nitrite Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect ____________ Para__________ Location Approved Date www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF vICTAuLIc COMPANY. 02017 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV_N \,htuIicr 11.02_i DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½"/50 x 15mm through 8 x 4"/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N j"IT :App,oy. II 2 1/2 (a) D 920N 500 1.50 2.00 2.53 1.61 I 5.35 2.75 3.1 50X15 3410 ii_51 164 41 136 7041.5 3/4 (a) U 920N 500 1.50 1.97 1 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 j 1.5 - 1(a) U 920N ' 500 1.50 1.85 I 2.53 1.61 5.35 2.75 3.0 25 3450 38.1 47 ,j 64 - 41 136 70 1.4 - 1¼ (a) tU 500 1920N.75 2.05 2.75 3.00 1.61 3 5,35 3.00 3.5 3.2 32 3450 1 44.5 52 70 76 41 136 76 1.7 1.5 11/2 (a) to + 500 -4--+---+- 1.75 2.03 ( 2.75 -'- 3.12 --+ 1.61 - 5.35 3.25 3.6 3.2 40 920N 3450 I 500 I 44.5 1.50 52 I 2.21 70 2.74 79 41 1 1.82 136 5.64 83 2.75 - 1.7 3.0 1.5 21/2 ½ (a) §n 65X 15 345038i456 70 46 H370414 4/4 (a) §u 920N - 500 1.50 2.18 2.74 1.82 5,64 2.75 3.0 20 - 3450 38.1 55 70 - 46 143 70 1.4 - 1(a) §U 920N , 500 1.50 1 2.06 2.74 I - I 1.82 5.64 2.75 2.9 25 3450 4, - 38.1 ------ 52 70 46 + - 143 - -- 70 --- 4- 14 - - 1¼ 1(a) U 500 1.75 2.30 - - I 3.00 3.25 I 1.82 6.29 3.00 3.5 3.2 32 92 N 3450 14.5 76 83 46 160 761.7j1.5 1 ½ 1(a) U 920N - 500 , 2.00 j 2.28 3.00 3.25 1.82 6.26 3.25 3 3.6 I 3. 40 920N - 19.8j.58 300 1,50 . 2.22 T i 2.75 I 83 . 46 2.25 159 6.46 83 3.18 I I1J 3.9 761 ½(a) 15 2065 1 56 4].9_.L ._Z_ 164 81 1.8 3/4 (a) 920N 300 150 I 2.19 2.75 2.25 6.46 I 3.18 3.9 1 20 2065 I 38,1 56 70 - 57 164 81 1.8 - 1 (a) 920N 300 1.50 ) 2.07 2.75 I 1-- 2.25 6.46 + --------- 3.18 3.8 25 .L 2065 . .... L 70 57 164 81 1.7 1¼ (a) U 920N 500 1.75 2.30 3.00 3.31 1.92 6.29 3.00 3.5 3.2 32 3450 44.5 I 58 1 76 84 49 160 I 76 1.6 1.5 1½ (a) U 2 N 90 500 2.00 2.28 3.00 3,31 1.92 6.29 I 3.25 3.5 3.3 40 , 920N 3450 500 58 1.50 58 2.52 Th 3.05 84 - 49j 2.28 160 6.15 83 2.75 1.6 3.4 1.5 3 ½ (a) U 80 15 ~ (a) U 920N 3450 500 38.1 1.50 64 2.49 78 - 3.05 - - 58 -- 4 2.28 - 156 -.-. 6.15 70 -, 2.75 1.6 -- + 3.4 - 20 3450 38.1 63 78 - 58 156 70 1 1.6 - 1(a) 920N 500 1.50 2.38 3.06 2.28 6.15 2,75 3.3 25 .p - 3450 38.1 -i-- 61 78 --- - --+ I 58 -+--- 156 70 - 1.6 -4---- - 1¼ (a) to 500 1.75 2.55 3.25 3.56 2.28 6.15 3.00 3.8 3.7 32(b) 3450 44.5 65 83 90 58 156 76 - 1.8 1.8 1½ (a) to 500 2.00 2.78 3.50 3.56 2.28 ' 6.15 3.25 4.1 3.8 40(b) 920N 50.8 71 89 58!156 83 19 L8 2 (a) U 920N 500 I 2.50 2.75 3.50 3.56 2.28 6.75 3.88 4.9 4.6 50 920N j 3450 ' 63.5 500 2.50 I 3.00 89 L 90 3.75 58 2.44 172 6.72 99 3.88 2.3 2.1 3.8 3½ 2 90 __50 3450 _63.5 76 - 95 62 _171 99 1.8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 1 Available with grooved or female threaded outlet. Specify choice on order. Center of run to end of fitting. II Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21h" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF vlCTAuLIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1LO2_2 'J(taUIIC REV_N DIMENSIONS GROOVED OUTLET SOMME lot 101, WOW imi FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Size Style No. M x. Work Prassure@ Dimensions Appr Weight x. Each I [ I U I Wi1 =am UItiti13 ' R TABLE CONTINUED FROM PAGE 2 4 1/2 (a)0 920N 500 I 1.50 303 3.56 I 2.69 7.01 2.75 3.7 X 15 100 345038.1 77 9O 6 7870 1.8i 8f1 14(a) U 500 920N 1.50 3.00 3.56 2.69 I 7.01 2.75 3.7 20 3450 38.1 76 90 68 178 70 1.8 - 1(a) a 500 ' 1.50 2.88 3.56 2-.- .69 7.01 2.75 3.6 25 3450 I 38.1 73 90 - - 68. 178 I 70 1.8 - 14 (a) to 920N 1 500 . 1.75 3.08 3.78 1 4.00 -- 2.69 7.01 i 3.00 4.0 3.6 9 68 178 ,76 _,- 19 L8 11/2 (a) to 920N 500 2.00 . 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) 3450 50.8 83 102 102 68 178 1 83 2.0 1.9 2 (a) to 920N 500 2.50 I 3.25 4.00 4.00 -t.-t.-t 2.69 7.01 3.88 5.0 -~-, 4.6 50 3450 63'5 83 102 102 t L78 992.32i 22½(a) t 920 500 2.75 2.88 4.00 4.00 2.69 7.34 4.63 5.8 5.0 65 3450 - 69.9 73 102 102 - 68 .....--f'--''- 186 118 + I 2.6 2.3 -•- 761 920 500 2.75 2.88 4.00 2.69 7.34 4.63 6.4 mm 3450 69.9 73 - 102 68 1 186 118 - 2.9 t 3(a) t 2 1 500 3.50 3.31 4.50 4.12 2.69 7.73 5.12 I 8.4 6.4 80 88.9 _ 84 114 1 105~ 68 . 1264_130 3.8 '2 1 ¼ (a)a 108.0 x 920N I 500 1.75 3.08 3.78 2.63 7.64 3.05 . 5.0 1 32 3450 44.5 78 96 ' 67 I 194 78 2.3 - 1 ½ (8)a 20N 500 2.00 3.28 4.00 2.63 i 7.64 ( 3.25 5.0 40 3450 500 t 50.8 J2 83 L 41 194 83 2.3 2(a) 920N 2.50 3.25 4.00 2.63 7.64 4.00 4.0 50 3450 63.5 1 83 102 67 194 102 1.9 - mm 50076.1 I 2.75 2.88 4.00 4.00 2.63 7.64 . 4.29 - 8.0 4 7.8 3450 69.9 73 102 - 102 67 - - 194 -.-.- 109 - 3.6 3.5 3 (a) 920 500 3.50 3.31 4.50 4.50 I 2.63 7.63 4.88 6.8 ' 6.5 80 920 3450 500 88.9 2.00 84 4,03 114 4.75 114 4.75 -f --+- 67 3.16 194 9.70 I 124 3.69 3.1 7.4 .,-,.- 3.0 7.6 5 1½ (a) t 125X40 3450 50.8 102 Ui 121 80 24694 3.4j34 2 (a) t 920 500 2.50 4.00 4.75 4.75 3.16 9,70 4.38 8.2 ' 8.0 50.._ 4 3450 63.5 12. i 80 246 4 m 17 36 2½ (a) t 920 500 4 2.75 3.63 4.75 4.75 3.16 9.70 4.63 8.3 7.9 65 3450169.8192 121 12180 246 118 3.8 3.6 761 mm 2 9 0 500 2.75 I 375 4.75 3.16 9.70 4.63 8.0 3450 69.9 95 - 121 80 246 118 - 3.6 ,[ 3(a) t 920 500 I 3.50 ' 3.81 5.00 4.63 3.16 9.70 5.31 8.4 8.8 80 920N 3450 88.9 500 2.50 97 3.75 127 4.50 118 80 3.17 246 8.00 135 3.88 3.8 8.0 4.0 2 133.0 X 50 3 !. j. 500 4 2_ I .f . + 203 99 3' - . 920 3.50 3.81 5.00 3.00 9.46 5.31 8.0 80 3450 88.9 I 97 127 - ) 76 240 1 135 3.6 - I TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: *a Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be t Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 2'/2 BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.vjCtauliC.com Ac- atUIjC VICTAULiC IS A REGISTERED TRADEMARK OF viCTAuLIC COMPANY. © 2017 viclAuLic COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_3 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS -~f GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x ½"I50 x 15mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. res ure@ Dimensions Weight Each $ $GM am om I ir ft 1. TABLE CONTINUED FROM PAGE 3 1 ½ t 139.7 x 920N 500 2.00 3.78 4.50 3.30 8.23 3.25 7.0 40 3450 50,8 i 96 I 114 - 84 209 83 3.2 - t - .- -- -- - - + 2t N 500 2.50 3.75 4.50 3.30 8.23 3.88 9.0 50 920N 3450 500 63.5 1.75 95 4.43 114 5.13 - 5.13 84 3.79 209 9.15 99 3.25 4.1 5.1 - 4.8 6 11/4 X32(b) 150 345 0 44.5112 130 130 96232.183 2.3 2.2 1½ (a) to 9 ON 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 ( 5.1 40(b)2 3450 5081i2 130 130%232832A123 2(a) to 92014 500 2.50 4.38 5.13 5.13 3.79 9.15 3.88 6.0 5.6 so 3450 f 63.5 -+ - 111 130 130 96 232 99 2.7 2.5 2½920 .- 500 2.75 4.01 5.13 5.12 3.69 10.51 4.63 8.3 7.6 65 4 . 3450 500 69.9 _ 2.75 110 130 130 94 -t 267 -+ 118 - _ 3.8 '- 3.4 76.1 mma 4.15 5.21 3.69 10.51 4.63 8.4 3450 69.9 105 - 132 94 1 267 118 - 3.8 3(a) t 500 3.50 4.31 5.50 - 5.13 3.69 -f-+- 10.51 I 5.31 . 9.9 - 8.4 80 920 3450 88.9 110 140 130 94 267 135 45 18 4(a) to 920 500 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 3450 500 114.3 2.00 97 4.41 146 5.13 137 I 94 3.63 267 9.40 I -4-t- 159 1 3.25 4.6 7.8 4.6 1½ (a) 15 x .0 40 3450 50.8 112 I 130 - 92 239 I 83 3.5 - 2(a) 920N 500 2.50 4.38 5.13 3.63 -, 9.40 3.88 1 8.0 so 3450 63.5 111 130 92 239 99 1 3.6 76.1 mm 9 20 3450 500 2.75 4.38 5.50 5.13 3.63 9.40 4.63 9.5 9.5 ,ggwo 1301 2 2 3 920 500 3.50 I 4.31 5.50 5.13 3.63 9.40 5.31 8.1 14.0 80 3450 88.9 k 110 140130 .92 ....3iiJ. . 7 6.4 I 500 4.50 4.45 5.38 3.63 9.40 6.12 10.0 0aomm92o 3450 1 11'4.3 113 ii.4.5 4 920 500 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 92 239 159 1 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com (tauIic. vICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 vICTAuLIc COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS Y z GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HOPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm Si. Styl M X. Work Noe Pr'essure@~ Dimensions 6 d ' . U1IA QSW fm. I - - TABLE CONTINUED FROM PAGE 4 1 165.1 x 920N 500 1.50 3.88 I 4.56 3.79 9.34 2.75 8.0 25 3450 38.1 I99 .. 4. ..i -96 ?.? 70 - 3.6 1'h 920N 500 i 1.75 4.43 5.13 3.79 r 3.25 8.4 32 3450 -.-4 44.5 113 130 _. ..4 - I 96 237 83 I 3.8 + 1½ Ia) '1 920N 500 2.00 4.41 5.13 - + - 5.13 3.79 9.34 3.25 - 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 2 (a) t 500 2.50 ,-.'----+.t .-,..f---,'---t---. 4.38 5.13 5.13 . 3.79 9.34 1 3.88 I --+-.-+-.--. 8.5 6.0 50 3450 635 ' 111 130 130 96 237 99 I 3.9 2.7 76.1 mm 500 2.75 +--+- 4.01 5.13 -.t - 5.21 3.63 10.51 I 4.63 8.6 7.6 3450 69.9 110 I 130 132 92 267 118 3.9 3.4 3(a)te - 3.50 -+- 4.31 5.50 --+ ---- I 5.13 3.63 10.51 5.31 I 130 . 9 - 2 267t 135 - + 10.2 8.4 -+- 500 I 80 920 3450 1 88.9 110 140 4.6 3.8 4 (a) 920 500 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 920 2 500 2.75 5.44 .u 267 6.19 159 6.25 4.81 12.42 4.50 4.8 11.6 11.6 8 2(a) t 200X50 3450 69 159122 500 2½ (a) t 920 2.75 5.07 1 6.19 6.19 4.81 12.42 4,50 11.6 11.6 65 3450 - 500 69.9 2.75 129 - 157 . 157 122 316 114 4 - 5.3 5.3 - 76.1 mm 5.25 I - 6.25 . 4.81 12.42 l 4.56 - 11.6 • 3450 69.9 .- 133 159 122 1 316 ) I ---+-- 5.3 1-- 3(a) 920 500 3.50 '1-•' 5.31 j 6.50 4 6.50 4.81 12.42 5.31 12.6 11.6 4(a) to 500500 4.50 4.81 6.75 6.38 4.81 I 12.42 6.25 15.3 12.5 100 - 3450 1143 122 171 162 122 j316 159 6.9 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT' clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 vICTAuUc COMPANY. ALL RIGHTS RESERVED. REV_N \%taulict 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-T® fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Formulas for Values: IsP =Q2 Where: Isp = Q2 Where: v Q=Flow(GPM) Q= Flow (m3/hr) AP = Pressure Drop (psi) Q = x Flow Coefficient IFAP ç= V AP = Pressure Drop (Bar) U LJ J Q = K x 4i K= Flow Coefficient Exaggerated for clarity Equivalent Length of Outlet Size Schedule OUTLETsara 40 Carbon Steel Pipe jiTb e1:1sI.1'Ji Cv/Kv Values ½ 0.840 15 21.3 '/4 1050 - 4 - 16 20 26.7 13.7 1 1.315 .. 3 8 21 25 33.7 - 1.8 14 1 6 50 48 32 I 42.7 42.9 41.1 1 ½ 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 10 ½ 112 104 50 60.3 96 89.1 21/2 2.875 20 121'1 119 150 65 73.0 102 128.5 76.1 mm I 3.000 16 - 161 - L. . 3 3.500 14 15½ 249 237 80 889 213.4 203.1 4.500 20 22 421 401 100 114.3 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.165in14.2mm. 1 FireLock° Innovative Groove System (IGS) outlet www.victaulic.com taulicr vicTAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_6 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. 21/2-6 2.875 - 6.625 All 10,40 400 400 400 290 232 362 65-150 73.0-16831 2755 2755 2755 1999415991 2496 21/2 - 4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 l -+- 2065 —..t 2065 - 2065 - I 1999 - 1- 1599 - 2496 - 21/2-4 2.875 - 4.500 I All SF 300 300 300 290 232 362 65-100 73.0-114.3 6.625 10 - t-. 2065 — 300 f 2065 -- 300 I 2065 + —. 250 I 1999 + 290 + I 1599 - 232 2496 362 6 150 168.3 6.625 34 30,40 2065 300 i 2065 300 1724 i 300 1999 290 1599 232 2496 -- 362 6 150 168.3 4 - 2065 2065 i - - 1999 t 1599 2496 8 8.625 I 21/2 10,41 400 — I — - 145 200 219.1 8.625 3, 4 10 300 4 . 250 1000 145 8 200 219.1 8.625 34 3040 . 2065 300 . — — 1724 300 — - 1000 145 — 8 200 219.1 2065 I 2065 I 1000 NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation VIC-TAP II HOLE CUTTING TOOL FOR 4 - 87100 - 200 MM CARBON STEEL PIPE The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500 psi/3450 kPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5'/125mm, 6'/150mm and 87200 mm diameter pipe. The Style 931 comes with a 21h'/65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCl) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com .4tuiic.° vIcTAuLIc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_N 11.027 MechanicaIT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 148O REV N UPDATED 12/2017 ictehulie viclAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 vtcuic COMPANY. ALL RIGHTS RESERVED. 11.02_L FireLock® STYLE 922 The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 1/4 through 76.1 mm/32 to 76.1 mm piping systems, Style 922 outlets are UL/ULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2O68kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF ViCTAIJLIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERvED, REV.G \4tauIic 10.521 IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 DIMENSIONS MAI -U I_I • Dimensions inches/millimeters Weight Each 1A ½ 1 1.30 1.83 1.10 3.87 2.56 1.0 32 x 15 30.2 133.0 46.5 2Z9 98.3 65:0 0.45 + ~ 1 3A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 46.5 27.9 98.3 f-4 65.0 0.50 . 1 1 3/16 1.52 2.18 1.10 I 3.87 2.56 1.2 25 30.2 1/6 38.6 1.42 55.4 1.95 27.9 1.22 98.3 4.08 65.0 2.56 4 0.54 1.2 1½ 1/2 40 15 30.2 36.1 1 49.5 31.0 103.6 65.0 ' 0.54 + t 3/4 1 1.40 1.95 1.22 4.08 2.56 I 1.2 20 30.2 35.6 49.5 31.0 103.6 65.0 0.54 - 1 11/16 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 1 41.7 1 1.66 58.4 2,19 31.0 1.46 103.6 4.60 65.0 2.56 0.59 1.3 2 1h 50 x 15 30.2 - 42.2 55.6 37.1 116.8 65.0 0.59 '/4 13/16 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 1 41.7 55.6 37.1 116.8 65.0 0.64 4 1 1/6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 13A6 47.8 1.91 64.5 2.44 37.1 1.71 116.8 5.40 65.0 2.56 0.68 ' 1.6 21/2 ½ 65 x 15 30.2 i 48.5 62.0 43.4 1 137.2 65.0 0.73 3/4 1 3A6 i z 1.89 2.44 1.71 5.40 2.56 1,6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 . 1 1 3/16 2.13 2.79 1.71 5.40 2.56 1.6 25 30.2 1 t-io 54.1 1.91 70.9 2.44 43.4 1.71 137.2 5.50 65.0 2.56 0.73 1.6 ½ 761 mm X 15 30.2 48:5 1 62.0 43.4 1 139.7 65.0 0.73 t 1 3/16 1.89 2.44 1.71 5.50 2.56 1.6 20 30.2 48.0 62.0 43.4 139.7 65.0 0.73 t 1 1/6 2.13 2.79 1.71 5.50 2.56 1.7 25 30.2 54.1 70.9 43.4 1 139.7 65.0 1 0.80 f Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAtJLIC IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. C 2009 vICTAuLIc COMPANY. ALL RIGHTS RESERVED. 1O.52_2 jtauIic' REVG IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Hazen-Williams Coefficient of friction is 120 www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVG 10.52_3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV 0 UPDATED 12/2009 ictaulic viciuic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY- 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.52 Ductile Iron Threaded Fittings SMITH..,COOPE9 INTERNATIONAL Ductile Iron Threaded Fittings Specifications <: branded ductile iron threaded fittings are UL Listed and FM Approved at 500 psi Rated to 300 WSP cULus o Ductile iron castings conform to ASTM A536 LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300# Class Threaded Fittings -20 to 100 500 150 200 -- 500 480 250 460 300 440 350 420 400 380 400 450 500 360 340 - 550 600 650 - 320 300 Fig. 35E 3_900 Elbow c®uS <Ce> APPROVED LISTED 1'! Size in Part N umber I U er A in Packing Weight lb Inner Master 1/2 35E 3004 35E 3006 1.13 100 200 140 80 50 0.2 3/4 1 1-1/4 1.31 70 0.3 0.5 0.8 35E3010 35E 3012 1.50 40 25 1.75 1-1/2 2 2-1/2 35E3014 35E 3020 35E 3024 1.94 2.25 18 36 - 20 1.1 1.8 3.2 10 2.70 4 8 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4 x 1/2 35RE3006004 35RE3010004 1.20 1.22 80 160 140 100 70 70 0.3 0.4 1 x1/2 1 x3/4 1.26 1.38 1.36 1.45 70 50 35RE3010006 0.4 1-1/4x1/2 1-1/4 x 3/4 3 301200 - 35RE3012006 1.34 1.53 35 0.5 0.6 1.45 1.63 35 1-1/4x1 35RE3012010 1.58 1.67 30 30 25 60 - 60 50 40 36 0.7 1-1/2 x 1/2 35RE3014004 1.52 1.52 1.75 1.75 -0.6- 0.7 1-1/2 x 3/4 35RE3014006 1-1/2x1 35RE3014010 1.65 1.80 20 0.8 1-1!2x1-1/4 35RE3014012 1.82 1.88 18 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2x3/4 35RE3020006 1.60 1.97 18 16 12 36 32 1.0 2 x 1 2x1-1/4_ 35RE3020010 1.73 2.02 1.2 35RE3020012 1.90 2.10 24 1.3 2x1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1/2 x 1-1/2 35RE3024014 2.16 2.51 6 12 12 2.2 2.5 2-1/2 x 2 35RE3024020 2.39 2.60 6 k;!.. Fig. 35F 3-45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 - 0.88 150 300 0.2 3/4 - 35F 3006 0.98 80 - 160 80 - 0.3 0.5 1 35F 3010 1.13 40 - 1-1/4 35F3012 1.29 1.44 25 _20 10A 50 40 20 0.7 1.0 1.6 1-1/2 2 35F3014 35F 3020 35F 3024 1.69 2-1/2 1.95 4 8 1 2.7 Fig. 35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 35T 3004 3513006 1.13 80 30 160 60 0.3 3/4 1.31 0.5 1 35T3010 1.50 25 50 0.7 1-1/4 35T3012 35T3014 1.75 10 20 20 1.1 1.5 1-1/2 1.94 10 2 2-1/2 35T3020 2.25 6 12 8 2.4 4.3 3513024 2.70 4 111 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1/2 1x1/2 35RT3006004 35RT3010004 1.20 1.20 1.22 60 120 0.4 0.6 1.26 1.26 1.36 30 60 1x1/2x1 -- 1 x3/4 1x3/4x3/4 1x3/4x1 35R13010004010 1.50 1.36 1.50 1.45 30 25 35 60 50 70 0.6 0.6 0.6 35R13010006 35RT3010006006 1.38 1.38 1.31 1.45 1.38 1.50 1.45 1.50 35RT3010006010 25 50 0.7 1-1/4 x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 1-1/4x3/4 35R13012004012 35RT3012006 35R13012006012 35RT3012010 35R13012010004 1.75 1.53 1.75 25 15 20 15 50 0.9 1.45 1.75 1.58 1.45 1.62 1.58 1.62 1.75 1.67 - 1.53 1.63 30 40 30 50 40 0.9 1-1/4x3/4x1-1/4 1.0 1-1/4x1 1-1/4x1x1/2 1.0 0.7 0.8 1.34 1.26 25 20 1-1/4 x1x 3/4 35R13012010006 1.45 1.38 1-1/4x1x1 35R13012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 1-1/2x1/2 35R13012010012 1.75 1.69 1.75 15 16 30 32 1.0 1.0- 35RT3014004 1.41 1,41 1.66 1-112 x 1/2 x 1-1/4 35R13014004012 1.81 1.56 1.88 24 48 _1.1 1-1/2x1/2x1-1/2 35R13014004014 1.94 1.66 1.94 12 24 1.2 1-1/2x3/4 35R13014006 1.52 1.52 1.75 16 32 1.1 401.1 1-/2x3/4x1-1/4 35R13014006012 1.94 1.66 1.88 20 1-1/2x3/4x1-1/2 1-1/2x1 35RT3014006014 1.94 1.75 1.94 18 12 36 24 40 1.2 1.2 0.8 35RT3014010 35R13014010004 1.65 1.44 1.65 1.25 1.80 1.69 1-1/2x1x1/2 20 1-112x1x3/4 35R13014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35R13014010010 35RT3014010012 1.65 1.82 1.50 1.67 1.80 1.88 16 32 1.0 1-1/2x1x1-1/4 - 1-1/2x1x1-1/2 12 24 12 35RT3014010014 1.94 1.80 1.94 12 24 1.3 14 1-112x1-1/4 35RT3014012 1.82 1.82 1.88 12 24 1-1/2x1-1/4x1/2 35R13014012004 1.41 1.34 1.66 16 32 0.9 1-1/2x1-1/4 x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 11/2x11/4x11/435RT3014012012 1-1/2x1-1/4x1-1/2 2x1/2 182 175 188 14 28 13 35RT3014012014 35RT3020004 1.94 1.88 1.94 14 28 1.4 1.5 1.49 1.49 1.88 10 20 2x3/4 2x1 2 x 1 x 2 35R13020006 1.60 1.60 1.97 10 8 20 16 16 1.6 1.7 1.9 35RT3020010 1.73 1.73 2.02 2.02 2.25 35RT3020010020 2.25 8 2x1-1/4 35R13020012 1.90 1.90 2.10 8 16 1.9 2 x 1-1/4 x 2 2x1-1/2 2x1-1/2x1/2 35R13020012020 2.25 2.10 2.25 8 16 16 20 2.0 2.1 1.3 35R13020014 2.02 2.02 2.16 8 35RT3020014004 1.49 1.41 1.88 10 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 8 20 16 16 1.4 1.5 1.7 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 C c®uS <> APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 35BT3 - Bull Head Tee Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35813006010 1.45 1.45 1.37 30 20 60 40 0.6 1x1-1/4 35B13010012 1.67 1.67 1.58 -0.9,.- 1 x 1-1/2 1-1/4x1x1-1/2 35B13010014 1.80 1.80 1.65 1.82 15 15 30 30 1.0 1.2 35813012010014 1.88 1.80 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 20 1.3 1.6 1-1/4x2 35BT3012020 2.10 2.10 1.90 10 1-1/2x1-1/4x2 1-1/2x2 35613014012020 35BT3014020 2.16 2.10 2.16 2.02 10 8 20 16 1.8 1.8 2.16 2.02 SMITH-COOPER INTERNATIONAL' • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 cous APPROVED Fig. 3503 - Straight Coupling with Ribs LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 3/4 35CP3004 55- EF3CO(F 35CP3010 35CP3012 35CP3014 35CP3020 1.38 200 400 - 200 0.1 1.63 100 0.2 1 1.75 60 120 0.4 1-1/4 2.00 35 70 0.5 1-1/2 2 2.19 25 50 - 0.7 1.2 2.62 15 30 2-1/2 35CP3024 3.00 9 18 2.2 3'ikw1 71 Size in Part Number A in Packing Weight lb Inner Master 1 x 1/2 1 x3/4 35HB3010004 35HB3010006 - 1.06 180 360 0.2 1.06 180 360 0.1 i-1/4 x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35HB3014010 1.25 75 150 0.4 1-1/2x1-i/4 35HB3014012 35H B3020010 1.25 75 150 0.3 2x1 1.38 40 80 80 0.6 0.6 2x1-1/4 35HB3020012 1.38 40 20 1 35HB3020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3004 35SP3006 35SP3010 - 35SP3012 0.94 600 - 1200 0.07 0.1 0.1 3/4 1.12 350 700 400 1 1.25 200 - 1-1/4 1.37 100 200 0.3 - 1-1/2 35SP3014 1.44 80 160 - - 0.4 2 35SP3020 1.50 45 90 0.6 JI Fig. 35RC3 - Hex Reducing Coupling Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 1-1/4 x 3/4 35RC3010006 35RC3012006 1.69 60 120 80 - 40 0.4 2.06 40 0.6 1.0 2x 1 (not hex) 35RC3020010 1 2.81 20 Fig. 35HB3 - Hex Bushing 0 •,.iI ki L!4ij Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master 1 35U 3010 2.19 2.50 20 15 40 30 1.0 1.2 1-1/4 35U 3012 1-1/2 35U3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 wwwsmithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 1 35X 3010 35X 3012 35X3014 35X 3020 1.50 1.75 1.94 20 40 0.9 1.4 - 1.8 2.8 1-1/4 1-1/2 2 12 24 16 12 8 2.25 6 c®uS <€> APPROVED A A Fig. 3513- Cross LISTED Fig. 35RX3 - Reducing Cross Size in Part Number A in B in Packing Weight lb Inner I Master 1-1/4x1 35RX3012010 1.67 1.58 15 30 1.2 1-1/2x1 2 x 1 35RX3014010 35RX3020010 1.80 1.65 12 24 1.4 2.0 2.02 1 1.73 8 16 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 35C 3006 35C3010 0.87 0.97 300 200 600 0.1 3/4 1 1-1/4 400 0.1 1.16 110 70 220 140 0.2 0.4 35C 3012 1.28 1-1/2 2 35C3014 35C 3020 35C3024 1.33 1.45 - 50 100 0.5 25 50 0.8 2-1/2 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp Ii Size in Part Number A in Packing I Weight lb Inner 3/8 1/2 35BC3003 35BC3004 0,75 0.75 100 80 _Master 200 0.3 0.5 _160 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 9 FAX (323) 890-4456 • www.smirhcooper.com 114 [INSTALLATION STEPS •!A1IiflINTO WOOD & STii] DINSTLLATION STEPS - GEEWft INTO WOOD & STEEL I. Insert the appropriate nut driver into a 3/8" or 1/2"portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver light to the member. Begin installation when the nut driver spins freely on the SAMMYS, stop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #14SW red nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in puriin steel. I. Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4", 3/8", Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum pullout in puriin steel. INSTALLATION STEPS - ! i1 INTO CONCRETE: 1 Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8", 1/2", or metric all thread rod or bolt stock. (#14SW red nut driver used with 112" screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. FINSTALLATION STEPS - INTO CONCRETE: Using an SDS 250 carbide tip bit or HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammer/ rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver. Place tip of screw into the pro-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 3/8"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener. 11111 liii i1ul' ill ii Jim MIA SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. SAMMYSO FURSTEEL Made with Tekse Self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - lIT thicknesses. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Made in the U.S.A. Mtch a video dam 3JwwwMwbulldexcomJ 1/4" 8024957 DSTR 100 1/4-20 xl" TEKS 3 1510 (20 ga.) .036-20 ga 3/16" 25 125 114 8025957 DST 100 1/4-14 x I TEKS 3 446 (20 ga) .036"-20 ga 3/16 25 - 125 1/4" 8026957 DST 150 1/4-14x1-112TEKS3 970 (16 ga.) .036"-20 ga 3/16" 25 125 1/4 8027957 DST 200 1/4-14 x iTEKS3 - 446 (209a) .036%20 ga 3/16 25 125 114 8030957 TEK500 12-24x1-1!2TEKS5 3125 (3/16") .188-3/16 1/2" 25 125 -3/8*-8038957 DSTR 1 1/4-20 xl TEKS 3 1510 (20 ga:) 1500 1475 .036"-2.0. ga 3116' 25 125 3/8" 8037957 DSTR 1-1/2 12-24x1-112" TEKS 5 1510 (3/16") 1500 1475 .060"-l6ga. 1/2" 25 125 #14 Black Q' 3/8 8039957 DSTR 516 5/16-18 xl 1/4 TEKS3 2200(20ga) 1500 1475 .036"-20 ga- 3/16 25 125 Nut Driver Pa 310 3/8" 8040957 DST 10 1/4-14x1"TEKS3 446 (20 .036"-20 ga 3/16" 25 125 - 3/8" 8077925 DST IO-SS 1/4-14x1"TEKS3 446 (20 ga.) 970 (16 ga.) .036"-209a 3/16" 25 125 3/8" 8041957 DST 15 1/4-14 x 1-1/2"TEKS 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8078925 0S115-SS 1/4-14x1-1/2TEKS3 446 (20 .036"-209a 3/16" 25 125 3/8" 8042957 DST 20 1/4-14x2TEKS3 446 (20 .036"-20 ga 3/16" 25 125 3/8 8043957 DST 25 1/4-14x2-1/2TEKS3 446 (20 .036"-20 ga 3/16" 25 125 3/8" 8044957 DST 30 1/4-14 x 3"TEKS 3 446 (20 .036"-20 ga 3/16" 25 125 8045957 DST 516 5/16-18 x 1-1/4"TEKS3 1500(3/16) 1500 1475 .125"-1/8" - 3/16" 25 125 3/8" 8046957 TEKSO 12-24 x 1-1/2"TEKS 5 3125 (3/16") 1500 1475 .250"-1/4" 1/2" 25 125 1/2" 8031925 DST 2.0 1/4-14x2" TEKS 3 446 (20 .188"-3/16" 1/4" 25 125 1/2" 8033925 DSTR 1.0 1/4-20 x 1"TEKS 3 1510 (209a.) .036'-20 ga 3/16" 25 125 I 1—/2.8034925 DSTR 5I6 5/1618x1 1/4 TEKS3 2220(20ga) .036.-20 ga 3/16 25 125 1/2.8035925 DST 5 16 5116-18 x 11/4 TEKS3 1500 (3/16) .125"-1/8" 3/16 25 125 #l4SWRed L L. 1/2 8036925 TEK5O 1224x11/2 TEKS5 3125 (16) .188"-3116" 1 25 125 Nut Driver Part #8114910 'Includes retaining nut SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins MA ft Y M free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 4I7AYSI jJJ•JILI(L"II Made with Tekse self-drilling fasteners - no pre-drilling required. ii O Installs into steel range from 20 gauge - 1/2" thicknesses. ç \ A standard screwgun with a depth sensitive nosepiece should be used to p r e r e d install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. "Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. idcha video demoostration oil Made in the U.S.A. WWW.itWbuiIdeLcomJ Approvals Rod Size Part Model Number Screw Descriptions Ultimate UL Test FM Test Min Max Pullout (lbs) Load (lbs) Load (lbs) Thickness Thickness Box Qty Case City I - 1/4" 8047957 SWD 100 1/4-14 xl' TEKS 3 1477 (16 ga.) .060-16 ga 3/116" 25 125 1/4" 8049957 SWDR100 1/4-20 x 1"TEKS 3 1900 (?Q ga) - - .036"-20ga 3/16" 25 125 3/8" 8050957 SWD 10 1/4-14x1' TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 8080925 SWD 10-SS 1/4-14x1'TEKS3 - 1477(16ga.) - .060"-16 ga 3/16 25 125 3/8 8051957 SWD 15 1/414x1 1/2 TEKS3 1477 (1 ga) .060"-16 ga 3/16 25 125 3/8 8052957 SWD 20 1/414 x 2 TEKS 3 1477 (16 ga) .060"-16 ga 3/16 25 125 3/8" 8053957 SWD 516 5/16-18 a 1-1/4" TEKS 3 2480 (20 ga.) .036-20 ga 3/16" 25 125 3/8" 8055957 SWDR1 • 1/4-20x1'TEKS3 1900 20 ga.) 1500 1475 .036"-20 ga 3/16' 25 125 #14SWRed 318" 8054957 SWDR1-1t2 12-24x1-1/2' TEKS 5 2375 (3/16") 1500 1475 .188"-3116' 1/2" 25 125 Nut Driver .e 3/8 8056957 SWDR 516 - 5/16-18 x 11/4 TEKS 2oga 2480 () 1500 1475 036 -20 ga 3/16 25 Part #8114910 - 3/8" 8057957 SWTI5 12-24x1-1/2'TEKS5 2375(3/16") .188"-3/16" 1/2" 25 125 "Includes retaining nut Application Product Features Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. "Installs into angled z-purlin; allows threaded rod to hang plumb. "Allows 17° deflection from vertical. "Made in the U.S.A. olMkh avdw nseoton7\ www.Itwbulldex.comJ Approvals Rod Part Model Screw Ultimate UL Test FM Test Min Max Box Case Size Number Descriptions Pullout (lbs) Load (lbs) Load (lbs) Thick Thick City Cty r1 NutDri1 e 44 3/8" 8137957 SI-l-DSTR V TEKS 3 l/4 3220(3/16') 1500 1475 .035' 3/16" 25 125 Part #8113910[ 2368(112" steel Vertical) 4)" 3/8" 8268957 SH-TEK 50 12-24 x 1-3/4" 1306(45° off Vertical) 1500 (Vertical) 4' 3/16' 1/2" 25 125 TEKS 5 2281 (3/16" HSS) 650(45° off Vertical) 2-1I2" 1585(3/16" HSS 45° off Vertical) 2368(112' steel Vertical) 1)2" 8270957 SI-l-TEK5O 12-24x1-3/4" 1306(45° off Vertical) 3/16" 1/2" 25 125 TEKS 5 2281 (3/16" HSS) #14SH Orange 1585(3/16" HSS 45° off Vertical) Nut Driver - Part# 8273910 Does not comply with ROHS requirements /Includes retaining nut S A 11411/1 Y X- P R E S S® Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: light gauge steel deck or purlin (22 ga. - 118'). Installs in seconds with Sammy X-Press ta Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. cfrtch a video damonst,ation at www.11wbuildex.com 1/4" 8181922 XP 200 Sammy 1146 (22 ga)185 (Luminaire) .125" 25 125 Metal Deck 250 (L.rninaire) 850(2W Pipe) .027" o (2" Pipe) 029" . S 3/8" 8150922 XP 20 Sammy1146 X-Press 20 (22 ga) 185 (Luminaire) 250 (Luminaire) .027' .056, 1475 (4 Pipe) .104" 125' 25 125 Metal Deck 283 (Conduit & Cable) .029' 1500 (4 Pipe) .060" c 318' 8153922 XP 35 Sammy 1783 (16 ga) 185 (Luminaire) .029 25 125 Pudin X-Press35 250 (Luminaire) 416 .0 1475 ') :• .125' (Conduit & Cable) .059" r Metal Deck 3/8" 8150922 XP 20 Sammy1146(22ga) 850(2i4Pipe) Pre-Pour Structural Concrete@ 3000 psi 25 125 Metal L 20 Post-Pour Range II LWC~ 35 PCF (lbs/It) (Post-Pour) Pre-Pour Structural Concrete /8 3000 psi Post-Pour Range 11 LWCS 35 PCF (Ibs! ft) The SidewinderX-Press expands to provide 'Less jobsite material needed. horizontal attachment in: -16 ga - 3/16" steel- pudin, tubular steel. • No retaining nut required. Installs in seconds with Sammy X-PressIt" Tool, "Provides design flexibility. ti1!I: • saving time & installation costs. Made in the U.S.A. Use in applications where access to the back of fEEI the installed fastener is prohibited; ie. metal roof (StN(P) deck, tubular steel, or vapor barrier fabric. - Watch a vidoc den onsiratun.i\ www.lMbuildex.com) .. 3/8" 8293957 SWXP35 1798(l6gal 80 (Luminaire( 059" .125" 25 125 Pudin _46 (Conduit& Cable) !&1AYiSi .027" .125° 25 125 Metal Deck The SwiveIX-Press allows you to hang plumb in extreme roof pitches: 89° in z-puliin - 45° in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press Ita Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Watch a video demnst,atjcn at (40 www.itwbulldex.com 750(2" Pipe) Swivel 170 Vertical (Luminaire) 3/8" 8294922 SXP2O X-Press 80@45°(Luminaire) .029" 635 (2" Pipe) .029" .125" 25 125 Metal Deck 283 Vertical (Conduit & Cable) 233 @ 45° (Conduit & Cable) 1250 (3-1/2" Pipe) Swivel 250 Vertical (Luminaire) 4 <> 3/8" 8295922 SXP35 X-Press35 1558 Olf'/ert) 500 Vertical (Conduit .80 @ 90* (Lurninaire) 059" 635 (2" Pipe) .029" .125" 25 125 Purlin 333 @89° (Conduit & Cable) l/Z 8272957 SXP2O Swivel 1061 (22 ga Vert) X-Press 2.0 829 (45° Off yen) Swivel 1675 (16 Vent) 1/2" 8271957 SXP 3.5 X-Press 3.5 1558(89° Off Vert) .060" .125" 25 125 Purlin [•\: . - T1 t "The Sammy X-Press expands to provide direct vertical attachment in: -metal deck (22-l6gauge) z-pudin (18-16 gauge) Made in the USA Watchawideodemunatratlanat www.ilwbulldex.com 8194910 UXPIT" Universal X-Press It Tool 8152910 XPDB 25/64" Drill Bit 'Tool Inctudes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit. Vertical 8150922 8153922 8181922 8294922 8295922 8293957 185 250 185 250 185 250 170 80 250 80 80 .035" .027' .035' .027' .035' .027" .027' .060" .060' .060" XP 35 3/8" XP 200 1/4' SXP 20 3/8" SXP 35 3/8" SWXP 35 3/8" Vertical Vertical Vertical 45" Vertical 90" Horizontal .'APPROVALS 8007957 GST 10 3/6' Vertical CPVC 1.1/2' 300 1-1/2' 8020957 SWG 10 :3/6' Horizontal CPVC 1-1/2' 300 1-1/2' 8008957 GST2O 3/F.' Vertical 2-1/2' 850 1-1/2" 4' 1475 1-1/2' 8068925 GST2O-SS :3/1" Vertical 2-1/2' 850 1-1/2" 8010957 GST3O 3/6' Vertical 4" 1500 1-1/2' 4" 1475 1-1/2" 8009925 GST25-380 3/1" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 3/8' Horizontal 3-1/2' - 4"" 1500 1-1/2" 8021957 SWG 20 3/1" Horizontal 2-1/2'.3... 1050 1-1/2' 8073925 SWG 20-SS 3/F Horizontal 2-1/2' 850 1-1/2' 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2' 850 1-1/2' 8269957 SH-GST/CSI2O 3/8' 45" Angle offVertical 4' 1500 1-1/2' 8139957 SH-GST2O 3/8' 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" kaimm molagm- U, W. 8038957 DSTR 1 3/6' Vertical 4 1500 .035" 4' 1475 .105" 8037957 DSTR 1-1/2 3/6" Vertical 1500 .035" 4' 1475 .105" 8039957 DSTR 516 3/1" Vertical 4" 1500 .037' 4' 1475 .105' 8045957 DST 516 3/6" Vertical 4" 1500 .188' 4" 1475 .188' 8046957 TEK5O 3/6' Vertical 4' 1500 .250" 4" 1475 .188" 8055957 SWDR 1 3/6' Horizontal 4" 1500 .037' 4' 1475 .060" 8056957 SWDR 516 3/6" Horizontal 4' 1500 .037' 4" 1475 .060" 8054957 SWDR 1-1/2 3/8' Horizontal 4" 1500 .037" 4" 1475 .060' 8137957 SH-DSTR1 30 17° Angle off Vertical 4' 1500 .035" 4" 1475 105" 8268957 SH-TEKSO 3/ti" Vertical 2-1/2' 850 70" Angle off Vertical 4' 1500 8150922 XP 20 3/ti" Vertical 2-1/2' 850 .027' 4' 1475 105' 8153922 XP 35 3/6' Vertical 4' 1500 .060" 8294922 SXP 20 3/6" Vertical or up to 45" 2' 750 .027" 2" 635 .029' 8295922 SXP 35 3/8' Vertical orspto89° 3-1/2" 1250 .060" 2' 635 .029" 8293957 SWXP35 3/6" Horizontal 3-1/2' 1250 .060' SAMMYS FOR CONCRETE PIPE HA'IGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC2O 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2' 850 Pre-Pour Structural ©3000psi 8150922 XP 20 3/8" Vertical 2-1/2" 850 Post-Pour Ranae II LWC 5 35 PCF (lbs/ft°l 8150922 XP 20 3/8" Vertical 283 .027' Max 4 trade size EMT, RMC, and IMC 85 trade size rigid PVC conduit 8153922 XP 35 3/8' Vertical 500 .060" Max 4 trade size EMT 86 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max I trade size EMT, RMC, and IMC 85 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT 86 trade sze RMC, IMC, and rigid PVC conduit 8293957 SWXP 35 3/8" Horizontal 500 .060' Max 4 trade size EMT 86 trade sze RMC, IMC, and rigid PVC conduit 8149957 CZ2000 1/4" or 3]8" Onto Vertical Rod UL Listed 4S16 -Cable Hanger, Cat No. C-Z2000 Plenum Rated, Complies wl NEC Standards IISheet Steel IGauges Gauge No. 22 ga. 20 ga. 18 ga. 16 ga. 14 ga. 12 ga. 1/8" 3/16' 1/4" Nominal Decimal Equivalent .030' .036" .048" .060" .075" .105" .125" .188" .250' "SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-112" UL compliance with NEC Standards. ' SWG 25-380 Mwdmum pipe size lo wood timber or joist allowed by UL s "SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-112' UL and FM tests were performed in compliance with NFPA 13 Standards SWG 20 MaxImum rise size in wood tmbwr or test allowed be UL is 3' Fastening requirement: $ times weight of water-filled schedule 40 pipe plus 250 pounds. SPECIAL NOTES Engineering Note In 1996, the anchors listed by ULwere tested in plate steel that measured .188" and .118". Subsequent testing was done for z-purlin applications in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys® Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installaon, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at w.itwbuildex.com Sammys for Seismic Please visit w.itwbuildex.com for our current Seismic product offemng. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendaflons for composite joist UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1/8' GST 25-380 .280' 7/32" SWG 20 .182" 1/8' SWG 25-380 .280' 7/32' To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPA/NEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at w.itwbuildex.com PWtM&GER DISC WIlD AS COT MO CMOS ALSO LCIIDASMASCS FORUJSE -SI Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made In the U.S.A. Products Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/AoDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor LAODBS APPROM IndeDendent code evaluation IBC®/ IRC®2015 IBC®/ IRC® 2012 IBC®/ IRC®2009 IBC® / I RC@ 2006 ri Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 Jc. 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbt in. 1/4 Nominal embedment h 0 in. 1-5/8 2-1/2 Effective embedment het in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T. nst (Nm) ft-lb 18 (24) Wrench size in. 7/16 1 TnMis the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete' 2,3,4,5 Nominal Nominal Tension - pN Shear - On anchor embed. f = 2,500 psi f = 3,000 psi f = 4,000 psi f = 6,000 psi f'c = 2,500 psi f' = 3,000 psi f = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) / 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2,3,4.5 Nominal Nominal Tension - pN Shear - On anchor embed. IC = 2,500 psi "C = 3,000 psi f'C = 4,000 psi IC = 6,000 psi IC = 2,500 psi IC = 3,000 psi "C = 4,000 psi f = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by 1a as follows: for sand-lightweight, A = 0.68; for all-lightweight, X. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a Kseis = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aNCe = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWIK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear4 Seismic shear5 diameter thread diameter qv in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1/4 UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASO value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension 4N = pAfuta as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with 4V <0.64A 4 f as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with <q 0.60 A 4 f as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363.4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. iTihiediL'EThrad1UWngiO]i Frc~(As _osl~sq Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. Nu © 2013 Fire Protection Products, Inc. FPPI, ThreadRP are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke IFM~K, SYSTEM COMPA11BLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSIIEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5g1.Pail 55-gi drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300. KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 I toward edge from edge factor in shear4 uncracked concrete JAN 1RN .fRV 'RV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) 1 (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 1 0.61 0.33 1.00 0.65 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.88 n/a -- 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a zb E 4 (102) 1.00 0.85 1 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 g 5 (127) 0.93 0.80 0.70 0.89 0.98 5-1/2 (140) 0.83 0.72 0.93 -g 6 (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 10 (254) 0.89 Q. CO 11 (279) 0.93 12 (305) 0.97 14 (356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete1'2 Edge distance in shear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .L toward edge from edge factor in shear4 cracked concrete fAN 1RN 11V fRV fl, IHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2.1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2 (51) 0.78 0.67 1.00 0.77 0.62 0.58 0.62 0.33 1.00 0.66 n/a n/a 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4 (102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 1 0.66 0.97 1.00 0.81 CU 4-1/2 (114) 0.89 0.77 0.68 1.00 0.85 5 (127) 0.93 0.80 0.70 0.89 )2 5-1/2 (140) 0.98 0.83 0.72 0.93 6 (152) 1.00 0.86 0.74 0.98 7 (178) 0.92 0.78 1 1.00 8 (203) 0.98 0.82 9 (229) 1.00 0.86 10(254) 0.90 11(279) 0.94 12(305) 0.98 - 14(356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACI 318-14 Chapter 17. 3 Spacing factor reduction in shear, fAN' assumes an influence of a nearby edge. If no edge exists, then I NV = 4 Concrete thickness reduction factor in shear, INN' assumes an influence of a nearby edge. If no edge exists, then I NV = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 321 I 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWlK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation in upper flute Nominal Nominal internal Nominal Tension - 4N Shear - 4V Tension - pN Shear - 4V anchor thread embed. f'= 3,000 psif',= 4,000 psif',= 3,000 psif',= 4,000 psif',= 3,000 psif'= 4,000 psif'= 3,000 psif',= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWlK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck"2'3'4'5'678 Installation in lower flute Installation in upper flute Nominal Nominal Nomina Tension - N, Shear - V,, Tension -(pN Shear - On internal anchor thread embed. f'= 3,000 psif',= 4,000 psi f,= 3,000 psi f'= 4,000 psi f',,= 3,000 P5 f'= 4,000 psi f',= 3,000 psi '= 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1 /4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth .;. = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, Inc. (US) 1-800.879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800.363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies - Mm. 3/4 . " ) Min. 3,000 psi sand-lightweight or normal-weight concrete Upper X flute Minimum (typical) 20 gauge steel deck Min. 4-1/2" —Anchor Flute edge Lower (typical) flute Mm. 1-1/4' Mm. 12" (typical) (ridge) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACl 355.2 for mechanical anchors and ACl 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous AOl 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I H carbon steel screw anchor1'2 Nominal Internal anchor thread Tensile3 Shear4 Shear,' diameter diameter Nsw V V req in. (UNC) lb (kN) lb (kN) lb (kN) 3,370 750 335 1/4 1/4-20 (15.0) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N r = A N 4 f R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with v,, < A., 4 0.6 R as noted in GSA A23.3-14 Annex D. 5 Seismic shear values determined by seismic shear tests with <A 0 q 0.6 f.. R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espaSol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 iii Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.314 Anchor O.D. da in. 1/4 (mm) (6.4) Effective embedment2 1.92 h in. 1.18 (mm) (30) (49) Minimum nominal embedment2 2-1/2 h in. 1-5/8 nom (mm) (41) (64) Minimum concrete thickness 4-1/8 in. 3-1/4 min (mm) (83) (105) Critical edge distance cac in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance 5min,cac in. 1.5 (mm) (38) Minimum edge distance c in. 1.50 (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 I (mm) (51) (73) Minimum specified ultimate strength f.. psi 125,000 (N/mm') (862) Effective tensile stress area A in 0.045 se,N (mm2) (29.0) Steel embed. material resistance factor for reinforcement - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 Factored steel resistance in tension IN mr lb 3,370 D.6.1.2 (kN) (15.0) Factored steel resistance in shear V lb 750 D.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V req (kN) (1.5) Factored steel resistance in shear Vsar lb 725 D.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 Factored steel resistance in shear, seismic V reg (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete k - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete k - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 tPc.N - 1.0 D.6.2.6 Anchor category - - 1 D.5.3 (C) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 D.5.3 (c) Condition B5 Factored pullout resistance in 20 MPa uncracked concrete" Npruncr lb 665 1,645 D.6.3.2 (kN) (3.0) (73) Factored pullout resistance in 20 MPa cracked concrete Nprcr lb 340 815 D.6.3.2 (kN) (1.5) (3.6) Factored seismic pullout resistance in 20 MPa cracked concrete' Nprm lb 275 815 D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex D section 0.2. For all design cases, ip 5 = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k0) or uncracked concrete (k) must be used. For use with the load combinations of GSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with GSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qJ, = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESIR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure iii in uncracked concrete 1,2,3,4,5 Nominal Tension - N Shear - V ___________ I = 20 MPa f' = 25 MPa I = 30 MPa = 40 MPa I = 20 MPa f, = 25 MPa f,, = 30 MPa I = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure N in cracked concrete1'2'3'4'5 Nominal Tension - Nr Shear - V ___________ f' = 20 MPa f, = 25 MPa I = 30 MPa I = 40 MPa I = 20 MPa I', = 25 MPa I = 30 MPa f'c = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900p5i) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by X. as follows: for sand-lightweight, A. = 0.68; for all-lightweight, 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 I,Anchoring Systems 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6.7 H Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear - V Tension - N Shear - V anchor thread embed. f' = 20 MPa f' = 30 MPa f' = 20 MPa f' = 30 MPa f = 20 MPa f' = 30 MPa f'c = 20 MPa f'c = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585. 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) __________ __________ (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 H Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear -Vr Tension - Nr Shear -V, anchor thread embed. f' = 20 MPa f', = 30 MPa = 20 MPa f' = 30 MPa I , = 20 MPa f' = 30 MPa f' = 20 MPa = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by 0N,se = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1-5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWIK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 UNC 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc.(US) 1-800-879-8000 1 www.us.hiiti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiiti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Mm. effective embedment h in. Allowable load3 Ultimate load Tension lb Shear lb45 Tension lb Shear lb45 1/4-20 UNC 1-3/8 1 455 1 485 1,810 1 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS—EZ I (KH-EZ I) in hollow core concrete 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/8 11/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/211/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/813/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 13A6 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13A6 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 1'/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Component of State of California OSHPD Approved c L US Seismic Restraints System LISTED OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 .1 CUSTOMER SERVICE • 800.786.5266 www.tolco.com 1ftI6fY Fig. 25 - Surge Restrainer c®us USTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 Lwwwtölcoiorn] C5~1 COOPER B-Line Size Range - Secures 3/8" thru 7/8" rod in 1 "increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 - Rod Stiffener Component of State of California OSHPD Approved c@ us USTED Seismic Restraints System Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 1½ 11630 10370 510 OFFICE/MANUFACTURING FACILITY• 1315 SAMPSON AVE. - CORONA, CA 02879- PH: 951.737.5599 FAX: 951.137.0330 CUSTOMER SERVICE • 800.186.5266 www.tolco.com Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. ' For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in '.. hanger before before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) 0/4 (20mm) thru 8 (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1i 92A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of Fig. 200C Fig. 200F Fig. 200_2112 to 200-8 Fig. 200 Fig. 200S Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) OVOLCCY Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B3170NFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut C® US LISTED V V 200-I2 /211 (15) /8"-16 31/' (79.4) 2I8" (66.7) 11 (5.0) 200-I4 3/4" (20) /8"-16 31/8 ' (79.4) 21 /2 ' (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3/8' (85.7) 2I8" (66.7) 12 (5.5) 200-1/4 11/4' (32) /8"-16 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200-1I2 11/2" (40) /8'-16 3 /8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 (50) /8"-16 41/2" (114.3) (76.3) 15 (6.9) 200-21I2 21/2" (65) I8"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5 /8" (149.1) 4" (101.6) 29 (13.3) 200_31/2 31/2" (90) /8"-16 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8° (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"..13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2'L13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" (200) 1/2"_13 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified COOPER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - - - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) I to 200-2 g. in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved /4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°c) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. Fig. 200_1/2. 200-/4 Fig. 200_21/2 to 200-8 L -jx JJ]3 200M8-1/2 1/2" (15) M8 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4° (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2" (63.5) ii (5.0) 200M8-1 1" (25) M8 3/8" (85.7) 2/8" (66.7) 12 (5.5) 200M1-1 1" (25) MiO 3%" (85.7) 2/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4" (32) M10 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 1/2" (40) M8 3 /8" (98.4) 27/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) MiD 3/8" (98.4) 27/8" (73.0) 14 (6.4) 200M8-2 2° (50) M8 41/2" (114.3) 3° (76.3) 15 (6.9) 200M10-2 2" (50) MiD 41/2" (114.3) 3° (76.3) 15 (6.9) 200M-21/2 21/2" (65) MiD 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 311 (75) MiD 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) MiD 7/8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4° (100) M10 7 /8" (187.3) 5° (127.0) 35 (16.0) 200M-5 (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8° (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line I SL Old",:NY 4 Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /'-16 or 1/2°_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada" (cUL). Conforms to Federal Specification WW-H-171E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. TOLCO cj us LISTED 11 - - - - - - - - - - - 1 1 1 1 1 f ffl1 .. JJ (i 200H-2-3/8 2° (50) /8'-16 4/16' (115.9) 3I32" (81.7) 48 (21.8) 200H-2-1/2 2° (50) 1/2"_13 423/32" (119.8) 3/8' (85.7) 45 (20.4) 200H-21/2-3/8 21/2' (65) /8"-16 5/16" (134.9) 323/32 (94.4) 59 (26.7) 200H-21/2-1/2 21/2' (65) 1/2"..13 515/32' (138.9) 3/8' (98.3) 56 (25.4) 200H-3-3/8 3' (75) /8'-16 53/4' (146.0) 327/32° (97.6) 63 (28.6) 200H-3-1/2 3" (75) 1/2".13 5/8" (148.1) 331/32 (100.8) 60 (27.2) 200H-4-3/8 4" (100) I8"-16 6/8" (174.6) 4/16' (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2"13 71/32 (178.6) 419/32' (1116.7) r 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8° pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified COOPER B-Line FiGasketubriGant Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 1 500E LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. 1J LONL F P P I t: Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ System Compatible Program* Certified to NSF/ANS/Std 61 -G WE Vt.1I4'I *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Nu © 2012 Fire Protection Products, Inc. FPPI®, LubeFif are registered trademarks of Fire Protection Products, Inc.Lg FGG/BM/CZ, Blaze-Master", FlowGuard Golds and Corzane are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. 0 LL I pe Fi Th re ad Sealing Pa ste F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. FL3(i SYSTEM COI.4PATIW.E *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL+1 760 599-1168 +1800344-1822 FAX + 1 800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipefit® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BlC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com WU © 2012 Fire Protection Products, Inc. FPPI®, LubeFtO are registered trademarks of Fire Protection Products, Inc. FBC", BlazeMaster®, FlowGuard GoId and Corzan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A.