Loading...
HomeMy WebLinkAbout6161 EL CAMINO REAL; ; FPC2018-0290; Permit(àityof PERMIT REPORT Carlsbad Print Date: 02/17/2022 Permit No: FPC2018-0290 Job Address: 6161 EL CAMINO REAL, CARI.SBAD, CA 92009-1602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2131002400 Track #: Applied: 08/30/2018 Valuation: $80,369.28 Lot #: Issued: 09/13/2018 Occupancy Group: Project #: Finaled Close Out: 02/18/2021 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Inspector: Plan Check #: Final Inspection: Project Title: Description: VIASAT -BLDG 2 -SPRINKLER TI (27 HEADS) Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC ADRIAN GONZALEZ 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $536.00 Total Fees: $536.00 Total Payments To Date: $536.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A 11~it AlkN FIRE PROTECTION F fc, zo 18 -- 019D Fire Protection Contractor - License #989280 FIRE SUPPRESSION MATERIAL SUBMITTAL: PRODUCT DATA AND MANUFACTURER'S INSTRUCTIONS 18503 ViaSat Bldg. 2 - Day 2 6161 El Camino Real Carlsbad, CA 92009 APPLICATION FEATURES Sizes: U 21/2' U 3" U 8" U 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections Flanged ANSI B16.1 Class 125 OPTIONS (Suffixes can be combined) U - with OS & Y gate valves (standard) U G - with groove end OS&Y gate valves U L - less shut-off valves U LM - less water meter U - with remote reading meter U - with gpm meter (standard) U - with cu ft/min meter EXISTING S Designed for installation on potable water fire protection lines to protect against both backsiphonage and backpressure of polluted water into the potable water sup- ply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE ASSE® Listed 1048 (Horizontal and Vertical Flow-Up) AMA Compliant C51 0 (Horizontal & Vertical Flow-Up) UL® Classified (Horizontal) C-UL® Classified (Horizontal) CSA® Certified (Horizontal and Vertical Flow-Up) FM® Approved (Horizontal and Vertical Flow-Up) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Horizontal and Vertical Flow-Up, except 10" vertical) MATERIALS Main valve body Cast Iron ASTM A126 Class B Access covers Cast Iron ASTM A126 Class B Coatings FDAApproved Epoxy finish Internals Stainless Steel, 300 Series Cast Bronze ASTM B 584 Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers DelrinTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U Gate valve tamper switch (OSY-40) B _A- DIMENSIONS & WEIGHTS (do not include pkg.) DIMENSIONS (approximate) WEIGHT MODEL B E E WITHOUT WITH OS&Y SIZE A WITHOUT C D OS&Y GATE OS&Y F GATE GATE GATE VALVES GATE VALVES VALVES VALVES OPEN VALVES in. I mm in. I mm in. mm in. I mm in. I mm in. I mm in. I mm in. I mm I lbs. I kg lbs. I kg 65 371/81 943 22 559 4 102 10 I 254 163/81 416 137/8 352 4 102 101 I 45.9 211 I 95.8 F10 2 1/21 80 381/8 968 22 559 4 1102 10 I 254 187/81 479 155/8 397 4 102 101 I 231 1104.9 200 711/8 1807 48 1219 71/21 191 16 I 406 373/4 959 291/4 743 7 1/21 191 847 I 384.5 1323 I 600.6 250 841/8 2137 58 1473 9 1229 18 457 53/l 1162 353/8 899 9 1229 14101640.1 222811011.5 e 1 of 2 15 IL 10 FLOW CHARACTERISTICS MODEL 950DA 21/2" & 3" (STANDARD & METRIC) FLOW RATES (Ifs) 12.6 25.2 37.9 200 400 600 FLOW RATES (GPM) MODEL 950DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Its) 63.1 126.2 189.3 50.5 104 :1) 69 35 800 252.4 104 (I) 69 35 LU 4000 cc a. 0 1000 2000 3000 FLOW RATES (GPM) *Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. Unless oth- erwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacitythru Schedule40Pipe(GPM) Pipesize 5ft/sec 7.5ft/sec 10ft/sec 15ft/sec 21/2 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 PROTECTIVE ENCLOSURE 12 MIN. 30 MAX. SUPPORT DIRECTION OF FLOW MAIN INLET OUTDOOR INSTALLATION VERTICAL INSTALLATION SPECIFICATIONS The Double Check Detector Backflow Preventer shall be ASSE® Listed 1048, and supplied with full port OS&Y gate valves. The main body and access covers shall be epoxy coated cast iron (ASTM A126 Class B), the seat ring and check valve shall be cast bronze (ASTM B 584), the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Preventer shall be a WILKINS Model 950DA. Page 2 of 2 WILKINS OPERATION OF ZURN INDUSTRIES, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1 L2 Phone:905/405-8272 Fax:905/405-1292 Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) • Website: http://www.zurn.com FireLock® V34, K8.0 J -C tauIid Models V3401, V3402, V3405, V3406 40.15 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response V3405/V3406 V3405/V3406 V3401/V3402 Recessed Pendent Pendent Upright Approvals/Listings: C®US LISTEO 0786 P(E See Victaulic Publication 10.01 for more details. Product Description: These Model V34 standard spray sprinklers are designed to provide a large discharge capacity in a hemispherical pattern for use in commercial applications. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent may be utilized with a Model V34 recessed escutcheon which provides up to A719 mm of adjustments. Technical Specifications: Models: V3401, V3402, V3405, V3406 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1 I32/14 mm K Factor: 8.0 Imp./11.5 S.I.1 Nominal Thread Size: 3/4 NPT/20 mm Max. Working Pressure: 175 psi/1200 kPa Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart I For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. Note: upright models V3401 and V3402 not VNIIPO approved Job/Owner Engineer Exaggerated for clarity System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Sprinklers I FireLock® I K8.0, V34 I Publication 40.15 40.15 2547 Rev. I updated 6/2014 0 2014 victaulic company. All rights reserved. 1 ictaulic victaulic.com I Sprinklers I FireLock® I K8.0, V34 I Publication 40.15 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: LI Standard: 5.0 mm LI Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: LI Open End: V34 LI Recessed: V34 Sprinkler Finishes: LI Plain Brass LI Chrome plated LI White painted3 LI Flat black painted3 LI Custom painted3 LI Proprietary Nickel Teflon2 coating3 LI VC-2504 155, 200, 286SR Only: LI Wax3 For cabinets and other accessories refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. 2 Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance 40.15 2547 Rev. I updated 6/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 2 \4tau 11cr victaulic.com I Sprinklers I FireLock® I K8.0, V34 I Publication 40.15 Approvals/Listings: Model 71 APPROVALS/LISTINGS V3401 V3405 V3405 V3402 V3406 V3406 V3406 Orifice Size (inches) 17/32" 17/32" 7/33" 17/32" 17/32" 17/32" 17/32' Orifice Size (mm) 14 14 14 14 14 14 14 Nominal K Factor Imperial 8.0 8.0 8.0 8.0 8.0 8.0 8.0 Nominal K Factor S.1.5 11.5 11.5 11.5 11.5 11.5 11.5 11.5 Response Standard Standard Standard Quick Quick Quick Quick Deflector Type upright Pendent Recessed Upright Pendent Recessed Recessed Pendent Pendent Pendent Adjustment up to 3/4" up to /2" up to 3/4" Approved Temperature Ratings F°/C° 135°F/57°C 35°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/1 41 °C 286'F/1 41'C 286°F/141°C 286°F/141°C 286°F/141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 1 55°F/68°C 155°F/68°C FM 175°F/79°C 175°F/79°C 155°F/68°C 175°F/79°C 135°F/57°C 175°F/79°C 175°F/79°C None 200°F/93°C 200°F193°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 2 86°FI141°C 286°F1141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68 °C 135°F/57°C 135°F/57°C NYC/MEA # 62-99-E 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F193°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F1141°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C 135°F/57°C 135°F/57°C CSFM #7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F193°C 200°F193°C 200°F/93°C 200°F/93°C 200°F193°C 286°FI141°C 286°F/141°C 286'F/1 41'C 286°F/141°C 286°F/141 °C 360°F/182°C 360°F/182°C 135°F/57°C 135°F157°C 155°F/68°C 135°F/57°C 155°F/68°C 135°F/57°C VNIIPO7 None 175°F/79°C 155°F/68°C None 175°F/79°C 175°F/79°C None 200°F/93°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/1 41°C 200°F/93°C 286°F/141°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C VdS 175°F/79°C None None 175°F/79°C None None None 200°F/93°C 200°F/93°C 286'F/141'C 286°F/141°C 360'F/1 82'C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE 175°F/79°C None None 175°F/79°C None None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/1 41°C 360°F/182°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB 175°F/79°C None None 175°F/79°C None None None 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 360°F/182°C Fork Factor when pressure is measured in Bar, multiply S.I. units by 10.0 6 The density at = 12m2, H = 2.5 rn, shall be a minimum of: 0,014 dm3 /m.s at = 0,1 MPa; 0.02 dm3 / m.s at P = 0,3 MPa Note: Listings and Approvals as of printing. All are approved open. 40.15 2547 Rev. I Updated 6/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 3 J(tauIic• 37 mm/ 17Aa" 6 45 mm/ 13/4 64 mm/ 2½ victaulic.com I Sprinklers I FireLock® I K8.0, V34 I Publication 40.15 Dimensions: Standard Pendent— Standard upright - V3405, V3406 V3401, V3402 2W/SO mm Max. Hole 2/S1 mm Mm. Hole 18mm k >7,'I 47 mm 1W! Typical Ceiling Tile MJTP~~M 29m 1W! - Finished Surface 34mm MAXIMUM RECESS 2 1AeV75 mm —1 MAXIMUM EXTENSION ½ Adjustment Recessed - V3405, V3406 (drawing not to scale) 2 WISO mm Max. Hole 2"/51 mm Mix Hole 1W! 24 rnm 16 mm 35 mm Typical Ceiling Tile 1 WI 1W! Finished Surface 29 mm 47 mm ~? I MAXIMUM RECESS - 2"A6775mm - MAXIMUM EXTENSION 3/4"Adjustment Recessed - V3405, V3406 (drawing not to scale) 40.15 2547 Rev. I updated 6/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 4 \/tauI.c victaulic.com I Sprinklers I FireLock I K8.0, V34 I Publication 40.15 Distribution Patterns: Models V3405, V3406 K8.0 Standard Pendent and Recessed Pendent Distribution Patterns - Trajectory 1 2 4' 6' 8' 10' 12' 14' 16' 0.6m 1.2m 1.8m 2.4m 3Gm 3.7m 4.3m 49m Models V3401, V3402 K8.0 Standard Upright Distribution Patterns - Trajectory ivaaiuiuuuu uuu•umsuuuuii mom iaiuuiiuu mom i•iuiiaauuu II.uIII.uII.I iism•uMOON iiaumu• 0 UUIUUUIULU ••UIk 0.6m 1.2m 1.8m 24m 30m 3.7m 4.3m 49m 2' 4' 6' 8' 10' 12' 14' 16' NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for Specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.15 2547 Rev. I Updated 6/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 5 'Atauiic 3Mm 8' 2.4m 6' l.8m 4, 1.2m 2' Oem 3Gm 10' 2.4m 8' iBm 6 11. 4. 0.6m 2' 7ps1 48 kPa 15 psi 103 kPa 30 psi 207 kPa 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K8.0, V34 I Publication 40.15 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -65°F (-54°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb Color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 Ff57 C 100 Ff38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F/79 C 150 Ff65 C Yellow Intermediate F 200 Ff93 C 150 F/65 C Green High J 286 F/1 41 C 225 F 8/107 C Blue Extra High 7 K 360 Ff182 C 300 Ff149 C Mauve - M Open - No Bulb Standard response only. All are approved open, except for areas designated No.' 8 150°F/65°C if wax coated. V34 Recessed V34 Open End V3401,V402 Upright V3405, V3406 Pendent V3405, V3406 Recessed Pendent 1 - WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. X__ Installation Reference should always be made to the 1-40 Victaulic FireLack Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specitications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic company. 40.15 2547 Rev. I Updated 6/2014 102014 Victaulic Company. All rights reserved. victaulic.com 6 \JtauIjC FireLock® V27, K5.6 Models V2703, V2707, V2704, V2708 Standard Spray Upright, Pendent and Recessed Pendent Standard and Quick Response TT V2703/V2704 V2707/V2708 V2707/V2708 Upright Pendent Recessed Pendent Approvals/Listings: 0786 See Victaulic Publication 10.01 for more details. Product Description: These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pattern for standard commercial applications. They are available with either standard or quick response bulbs. It is cast with a hex-shaped wrench boss to allow easy tightening from many angles, reducing assembly effort. This sprinkler is available in various temperature ratings (see chart on page 3) and finishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which provides Up to I411I19 mm of adjustments. Coverage For coverage area and sprinkler placement, refer to NFPA 13 or applicable standard. JtaUIic 40.10 Technical Specifications: Models: V2703, V2704, V2707, V2708 Style: Pendent, Upright or Recessed Pendent Nominal Orifice Size: 1/2 /13 mm K Factor: 5.6 Imp./8.1 SI.1 Nominal Thread Size: ½ NPT/15 mm Max. Working Pressure: 175 psi/1200 kPa (FM) 250 psi/1725 kPa (UL) Factory Hydrostatic Test: 100% @ 500 psi/3450 kPa Mm. Operating Pressure: 7 psi/48 kPa 0.35 bar/5 psi (VdS for upright only) Temperature Rating: See chart For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. Exaggerated for clarity Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. ictaulic 1 victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Material Specifications: Upright Deflector: Bronze per UNS C11000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solution Bulb Nominal Diameter: fl Standard: 5.0 mm El Quick Response: 3.0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon2 tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 Accessories Installation Wrench: El Open End: V27 El Recessed: V27-2 Sprinkler Finishes: El Plain Brass El Chrome plated III White painted3 Black painted3 Custom painted3 LII Proprietary Nickel Teflon2 coating3 LII VC-2504 155, 200, 286 SR Only: El Wax3 For cabinets and other accessories refer to separate sheet. 2 Teflon is a registered trademark of Dupont co. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. 40.10 2544 Rev. J updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 2 !JtauIic victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Approvals/Listings: Model APPROVALS/LISTINGS V2703 V2707 V2707 V2704 V2708 V2708 Orifice Size (inches) 1/7" 1/2" 1/2" 1/2" 1/2" 1/2" Orifice Size (mm) 13 13 13 13 13 13 Nominal K Factor Imperial 5.6 5.6 5.6 5.6 5.6 5.6 Nominal K Factor S.1.5 8.1 8.1 8.1 8.1 8.1 8.1 Response Standard Standard Standard Quick Quick Quick Deflector Type Upright Pendent Recessed Upright Pendent Recessed Pendent Pendent Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 135"F/57°C 155°F/68°C 155°F/68°C 155"F/68°C 155°F/68°C 155°F/68°C 135"F/57°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79"C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93C 175°F/79°C 286°F/141°C 286°F/141°C 286°F/141°C 286°F/141°C 286"F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57"C 135"F/57°C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C FM 175"F/79°C 175°F/79"C 155°F/68°C 175"F/79"C 175°F/79°C 155"F/68°C 200°F/93°C 200°F/93°C 175°F/79"C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141"C 286"F/141C 200°F/93°C 286"F/141°C 286F/141°C 200"F/93°C 360°F/182°C 360°F/182°C 135°F/57°C 135°F/57°C 135°F/57C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155F/68"C 155"F/68°C 155°F/68°C 135"F/57°C NYC/MEA 62-99-E 175°F/79°C 175°F/791C 175°F/79°C 175"F/79°C 175°F/79"C 155"F/68°C 200"F/93°C 200°F/93"C 200"F/93C 200°F/93°C 200°F/93°C 175°F/79°C 286°F/141°C 286"F/141°C 286°F/141°C 286"F/141"C 286°F/141°C 200°F/93"C 360°F/182°C 360°F/182°C 135°F/57"C 135°F/57"C 135"F/57"C 135°F/57°C 135°F/57°C 155F/68°C 155°F/681C 155°F/68"C 155°F/68°C 155°F/68°C 135"F/57°C CSFM 7690-0531:112 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 155°F/68°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93C 200"F/93C 175°F/79°C 286°F/141 "C 286°F/141"C 286°F/141°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C 135°F/57"C 155°F/68°C 135°F/57"C LPCB 175°F/79°C None None 155"F/68"C None None 200"F/93°C 175°F/79°C 286°F/141"C 200°F/93°C 360°F/182°C 135°F/57°C 135°F/57"C 135"F/57"C 135°F/57"C 155°F/68°C 155°F/68°C 135°F/57°C 155°F/68°C 155°F/68°C 135°F/57°C VNIIPO 175°F/79"C 175"F/79"C 155"F/68°C 175°F/79°C 175"F/79"C 155°F/68°C 200°F/93°C 200°F/93°C 175°F/791C 200°F/93°C 200°F/93°C 175"F/79°C 286"F/141"C 286°F/141°C 200"F/93°C 286°F/141°C 286°F/141°C 200°F/93°C 360°F/182°C 360°F/182°C ZSTZ ZSTX K-ZSTZ K-ZSTZ CCC 155°F/68"C 155"F/68°C None 155°F/68°C 155°F/68°C None 200°F/93°C 200°F/93"C 200"F/93"C 200"F/93"C 135"F/57"C 155"F/68°C 155°F/68°C VdS 175"F/79°C None None 175°F/79°C None None 200°F/93°C 200°F/93°C 286'F/141'C 286°F/141°C 360"F/182"C 135°F/57°C 135"F/57"C 155"F/68°C 155"F/68"C CE 175°F/79°C None None 175°F/79"C None None 20 0" F/93"C 200"F/93"C 286"F/141"C 286'F/141'C 360"F/182°C For K Factor when pressure is measured in Bar, multiply S.I. units by 10.0 FM Approved with I2" adjustment escutcheon only - quick response Note: Listings and Approvals as of printing. All are approved open. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. ictaulie victaulic.com 3 victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Dimensions: 6C 6C Standard Pendent - Standard Upright - V2707, V2708 V2703, V2704 2W/60 mm Max. Hole 2/51 mm Mm Hole 30 I 346/ 17mm TypicalCeilingTile i A ih1 ? t t 1iI 1'iló/ 3Oxm 43 mm ___________ MAXIMUM RECESS 2346/ 75 Finished Surface mm MAXIMUM EXTENSION ½' Adjustment Recessed - V2707, V2708 (drawing not to scale) 234/60 mm Max. Hole 2'/51 mm mm "A/I Mix Hole 24 ___ 37mm —i Typical Ceiling Tile 18mm __ 24mm Finished SurfaceY __________ MAXIMUM RECESS 2xAx / 75 mm MAXIMUM EXTENSION 34' Adjustment Recessed - V2707, V2708 (drawing not to scale) 40.10 2544 Rev. J Updated 07/2014 0 2014 Victaulic company. All rights reserved. victaulic.com 4 \)4'tauIiC ttt- 11111111 1 3am 8' 2.4m 6' 1.8m 7 psi 48 kPa 15 psi 103 kPa 30 psi - 207 kPa victaulic.com I Sprinklers I FireLock I K5.6, V27 I Publication 40.10 Distribution Patterns: Models V2707, V2708 K5.6 Standard Pendent and Recessed Pendent In, - Distribution Patterns - Trajectory 4' 6 6 10' 12' 14' 0.6m 1.2m 1.8,, 2.4m 3.om 3.7,,, 4.3m Models V2703, V2704 K5.6 Standard Upright Distribution Patterns - Trajectory iuimiiuiu su•iiiiiiuuu uumuuuuiuuu auauuuiuuu iiuuiu•iuuu iuuimuma mom IUIIlIIUkIIUI i•uii•iimiiii NEMENNNN uuuuuuuuuuui 2' 4' 6' 8' 10' 12' 14' 16' 0.6m 1.2m 18,,, 2Am 3.om 3.7m 4.3m 49m NOTES: Data shown is approximate and can vary due to differences in installation. These graphs illustrate approximate trajectories, floor-wetting, and wall-wetting patterns for these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance in avoiding obstructions to sprinklers and should not be used as minimum sprinkler spacing rules for installation. Refer to the appropriate NFPA National Fire Code or the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. All patterns are symmetrical to the centerline of the waterway. 40.10 2544 Rev. J Updated 07/2014 © 2014 Victaulic company. All rights reserved. victaulic.com 5 ,JtauIic 10, 8' 2Am 6' 1.8m 4, 1.2m 2' 0. 6m 7 psi 48 kPa 15 psi 103 kPa 30 psi 207 kPa victaulic.com I Sprinklers I FireLock® I K5.6, V27 I Publication 40.10 Ratings: Available Wrenches: All glass bulbs are rated for temperatures from -67°F (-55°C) to those shown in the table below. Sprinkler Temperature Classification Victaulic Part Identification Temperature - F! C Glass Bulb color Nominal Temperature Rating Maximum Ambient Temperature Allowed Ordinary A 135 F/57 C 100 F/38 C Orange Ordinary C 155 F/68 C 100 F/38 C Red Intermediate E 175 F179 C 150 F/65 C Yellow Intermediate F 200 F/93 C 150 F/65 C Green High J 286 F/141 C 225 F8/107 C Blue Extra High K 360 F/182 C 300 F/149 C Purple - M Open - No Bulb Standard response only. 8 150/65 if wax coated. V27-2 Recessed V27 Open End V2707, V2708 Pendent / / V2707, V2708 Recessed Pendent V2703,V2704 Upright / WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprin- klers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. O Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pam- phlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: WE 001-610-559-3300. Installation Reference should always be made to the 1-40 Victaulic FireLock Automatic Sprinklers Installation and Maintenance Sheet for the product you are installing. This installation sheet is included with each shipment of Victaulic products for complete installation and assembly data, and is available in PDF format on our website at victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic is a registered trademark of Victaulic Company. 40.10 2544 Rev. J Updated 07/2014 Itt 2014 Victaulic Company. All rights reserved. victaulic.com 6 J IN C Bull Moose Tube's Schedule 10 and Schedule 40 are FM Approved and UL Listed (for U.S. and Canada), even though these products do not require separate approvals and listings. Bull Moose Tubes made the decision to have them approved and listed. Our Schedule 10 and Schedule 40 have a pressure rating of 300 PSI and have been through the same rigorous testing as our other fine pipe products. Schedule 10 can be supplied roll grooved or plain end. Bull Moose Tube's* Schedule 10 and Schedule 40 pipes are hot dipped galvanized to meet ASTM Al 23 standards. All products are stencilled to meet FM & UL specifications. c®us LISTED APPROVE ON NFPX --- 4 SCHEDULE 10 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.097 15.27 1.41 lbs/ft 1.820 91 1-1/4 1.660 1.442 9.91 1.81 lbs/ft 2.518 61 1-1k 1.900 1.682 7.76 2.09 lbs/ft 3.053 61 2 2.375 2.157 627 264 lbs/ft 4.223 37 2-1./2 2.875 2.635 492 353 lbs/ft 5.893 30 3 3.500 3.260 3.54 4.34 lbs/ft 7.957 19 4 4.500 4.260 2.50 5.62 lbs/ft 11.796 19 SCHEDULE 40 PIPE SPECIFICATIONS NOMINAL PIPE O.D. I.D. WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR** WEIGHT/FT WEIGHT SIZE 1 1.315 1.049 1.00 1.68 lbs/ft 2.055 70 11/4 1.660 1.380 1.00 227 lbs/ft 2.918 51 1-1/2 1.900 1.610 1.00 272 lbs/ft 3.602 44 2 2.375 2.067 1.00 3.66 lbs/ft 5.114 30 21/2* 2.875 2.468 1.00 5.80 lbs/ft 7.875 30 3* 3.500 3.068 100 758 lbs/ft 10.783 19 4* 4.500 4.026 1.00 10:80 lbs/ft 16.316 19 'Only available in Casa Grande, Al "Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.buIlmoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grande, AZ Dallas, TX Masury, OH 63017 Dull Moose Tube's Eddythread 40 ADVANTAGES OF BULL MOOSE TUBE EDDVTHREAD 40® L) isa lightweight replacement for • Has a Corrosion Resistance Ratio of 1.0. Schedule 40 that has a Corrosion • Has a pressure rating of 300 psi. Resistance Ratio of 1. • Is lighter weight than Schedule 40. Is approved by Factory Mutual and listed by Underwriters Laboratories. Is produced in accordance to ASTM Al 35 and A795 Type E, Grade A. Can be used with standard Schedule 40 threaded fittings, couplings, and valves. Is produced from steel with excellent properties of strength and threadability. Can be used in wet, preaction, and deluge type sprinkler systems. Can be hot dipped galvanized to meet FM's requirement for dry systems. Offers lower freight costs. Supplied with EDDY GUARD 110 MIC preventative coating. c®us LISTED EDDYTHREAD 40 SPECIFICATIONS NOMINAL PIPE O.D. I.D. WEIGHT WATER FILLED BUNDLE SIZE (IN) (IN) (IN) CRR° LB./FT WEIGHT SIZE 1 1.295 1.083 1.00 1.461 1.860 70 1-1/4 1.650 1.418 1.00 2.070 2.754 51 1-1/2 1.900 1.654 1.00 2.547 3.468 44 2 2.375 2.123 1.00 3.308 4.842 30 'Corrosion Resistance Ratio per latest UL Directory listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. APPROVHJ ONFSA NFPX For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com U 1819 Clarkson Road Chesterfield, MO Geralct. MO Kent. WA Casa Grande, AZ Dallas, TX Masur OH 63017 Bull Moose Tube's® EddyliteO is a lightwall threadable pipe manufactured in NPS 1" through 2". EddyliteO is a truly unique product within the fire protection industry. This product has been engineered to provide lower cost fire protection systems without compromising service life, adequate wall thickness, or standard outside diameter. Eddylite® is manufactured to meet the requirements of ASTM A135 and A795 specifications. This pipe product has been fully approved by Factory Mutual, and listed by Underwriters Laboratories (for U.S. and Canada) for use in fire protection systems with a working pressure of 300 psi or less. c®us LISTED APPROVHI I;] 4 OWSA NFPA' 6 ADVANTAGES OF BULL MOOSE TUBE EDOYLITE Standard outside diameter, unlike some other lightwall threadable pipe products. Lighter in weight than Schedule 40. Superior burst strength and corrosion resistance ratio compared to other lightwall threadable pipe products. Exceptionally strong, meets or exceeds ASTM Al 35 minimum yield requirements. Can be used with standard couplings, fittings, and valves. Freight savings. Lower sprinkler system costs without compromising service life. Better hydraulics than Schedule 40. Wall thickness and weight close to Schedule 30; compare to other lightwall threadable water filled products with wall thickness less than Schedule 101 CORROSION RESISTANCE RATIO (CRR) NOMINAL STANDARD INSIDE UL UL WEIGHT WATER BUNDLE PIPE SIZE (IN) O.D. (IN) DIAMETER (IN) THREADED UNTHREADED PER FT. FILLED SIZE 1 1.315 1.137 0.13 7.47 1.260 1.700 91 11/4 1.660 1.482 008 479 1617 2.364 61 1-1/2 1.900 1.712 0.12 4.53 - 1.967 2.965 61 2 2.375 2.177 016 431 2617 4230 37 "Corrosion Resistance Ratio per latest UI. Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sates@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa GrandR AZ DallanjX Masurt OH 63017 c®us LISTED ADVANTAGES OF BULL MOOSE TUBE® EDDY FLOW® Certified to ASTM Al 35 and A795 Type E, Grade A. FM approved for roll grooving and welding for use in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight - saves shipping costs and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Can be supplied roll grooved or plain end. Can be hot dipped galvanized to meet FM's & UL requirement for dry systems. Supplied with EDDY GUARD Il® MIC preventative coating. NPS O.D. SIZE (IN) (IN) EDDY FLOW! (ID) EDDY FLOW! CRR* WEIGHT PER F1 WATER FILLED WT. BUNDLE SIZE 1-1/4 1.660 1.530 1.98 1.222 2.019 61 11/2 1.900 1.728 344 1.844 2.860 61 2 2.375 2.203 2.78 2.330 3.982 37 2-1/2 2.875 2.705 1.66 2.809 5.299 30 3 3.500 3.334 1.00 3.361 7.144 19 4 4.500 4.310 1.00 4.968 11.290 19 .Corrosion Resistance Ratio per latest UL Directory Listing PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. Q ® For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO KerttWA Cats Grande, AZ Dallas, TX Masury, ON - 63017 7 Bull Moose Tube's® Eddy Flow® is a specially engineered replacement for Schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL Listed (for U.S. and Canada) for roll grooving and welding. As an added benefit, it is more economical to use than Schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's® larger ID provides an opportunity for downsizing and further cost savings. APPRWM I;] A ONFM NFPX Dull Moose Tube's® Ultra Eddy® is ADVANTAGES OF BULL MOOSE TUBE® ULTRA EDDY® I) a versatile product that can be Certified to ASTM Al 35 and A795 Type E, Grade A. roll grooved, welded, and used with FM approved for roll grooving and welding for use in wet systems. Pressfit* Products. UL listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. Lightweight -saves shipping costs, offers easier handling. Multidimensional: Can be used with all Schedule 5 approved roll grooved, welding and Pressfit* Products for pressures up to 175 psi. Designed to generic Schedule 5 tolerances for easy interchangeability with all approved or listed fittings. Can be supplied roll grooved or plain end. 'With a larger ID than other products on the market today, Ultra Eddy® offers substantial improvements in hydraulics. This improvement allows for downsizing within the system which offers the opportunity for additional cost savings. Can be hot dipped galvanized to meet FM'S requirement for dry systems. NPS O.D. ULTRA ULTRA EDDY0 WEIGHT WATER BUNDLE (IN) (IN) EDDY0 (ID) CRR** PER FT. FILLED WT. SIZE 1 1.315 1.201 2.17 .868 1.359 91 1-1/4 1.660 1.546 1.40 1.107 1.920 61 1-1/2 1.900 1.786 1.11 1.274 2.360 61 2 2.375 ' 2.261 1.00 1.604 3.344 37 Pressfit is a Registered Trademark of Victaulic Company of America Corrosion Resistance Ratio per latest UL Directory listing c®us LISTED APPROVHI [] OMM NFPX i-'--- 8 PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@buIlmoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent WA Casa Grand AZ Dallas, TX Masurl OH 63017 NPS(IN) 1 1-114 1-112 2 2-1/2 3 4 c®us LISTED 0,D. (in) 1.315 1.660 1.900 2.375 r .0(8) 1.201 1.546 1.786 2.261 ULTRAEDDYO Empty Weight (ib/ft) 0.868 1.107 1.274 1.604 WaterFilied Weight lblft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 OD in) 1.660 1.900 2.375 2.875 3.500 4.500 lO(in) 1.530 1728 2.203 2.705 3.334 4.310 Empty Weight (Ibft) 1.222 1.844 2.330 2.809 3.361' 4.968 EDDY FLOWS Water-Filled Weight Ob/ft) 2.019 2.860 3.982 5.299 7.144 11.290 I CAR 198 344 278 166 100 100 fl OD (in) 1.31S 1.660 1.900 2.375 2.875 3.500 4.500 ID. (in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 SCHEDULE Emptyweighttft) 1.410 1,810 2.090 2.640 3.530 4.340 5.620 10 - Water Ailed Weightiblft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 - * C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 &D. in) 1.315 1.660 1.900 2.375 -1.D-. 64 1.137 1.482 1.712 2.177 EDDYLITEO mptyWeightO&ft) 1.260 1.617 1.967 2.617 NateiA0ed Weight fib/ft 1.700 2.364 2.965 4.230 jr C.R.R. 0.13 0.08 - 0.12 0.16 00 in) 1.295 1.650 1.900 2.375 LD.fin) 1.083 1.418 1.645 2.123 EDDYTHREAD 40 EmptyWeight(ibIft) 1.461 2.070 2.547 3.308 Water-Filled Weight fblft) 1.860 2.754 3.468 4.842 C.R.R. 1.00 1.00 1.00 1.00 O.D. 1.315 1.660 1.900 2.375 2.875 3.500 4.500 [ Din) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 SCHEDULE Empty Weight Qhif' 1.680 2.270 2.720 3.660 5.800 7.580 10.800 40 Water-Filled Weight(1b!ij 2.055 2.918 3.602 5.114 7.875 10.783 16.316 (PR 100 100 100 100 100 100 100 For Additional Information Contact (800) 325-4467 www.bulImoosetube.com Or From Canada Call: (800) 882-4666 sales@bulImoosetube.com 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent. WA Case GrandA2 Dallas, TX Masury OH 63017 APPROVHJ i:; t4!cf4 NFPX . c®us LISTED APPROVED oNfA NFPA' -=- 10 NPS PIPE WEIGHT PIECES WEIGHT WEIGHT WEIGHT TYPE PER FOOT PER BUNDLE PER BUNDLE PER BUNDLE PER BUNDLE ULTRA EDDY" 0.868 91 1,659 1,896 1,975 r SCHEDULE 10 1.410 91 2,695 3,079 3,208 1 r -.EDDY-LITE' 1.2 60 91 2,408 2,752 2,867 [EDDYTHREAD40] , 1.41 70 2,148 2,454 2,557 SCHEDULE 40 1 1.680 70 2,470 2,822 2,940 UITRAEDDY' 1.107 61 1,418 1,621 1,688 EDDYFLOW 1.222 61 1,565 1,789 1,864 SCHEDULE10 1.810 61 2,319 2,650 2,760 11/4 r EDDYLITE 1.617 61 2,071 2,367 2,466 EDDYTHREAD40 2.070 51 2,217 2,534 2,639 'SCHEDULE 40 ULTRAEDDY -, 2.270 1.274 51 61 2431 1,632 2,778 1,865 2,894 1,943 EDDY FLOW' 1.844 61 2,362 2,700 2,812 SCHEDULE 1O 2 090 61 2677 3060 3187 1-1/2 EDDYLITEO 1.967 61 2,520 2,880 3,000 EDDYTHREAD40' 2.547 44 2,353 2,690 2,802 rSCFIEDULE40 ULTRA EDDY 2.720 1.604 44 37 2,513 1,246 2,872 1,424 2,992 1,484 EDDY FLOW' 2.330 37 1,810 2,069 2,155 SCHEDULE1O 2640 37 2,051 2,344 2442 2 EDDYLITE' 2.617 37 2,033 2,324 2,421 EDDYTHREAO 40 3308 30 2,084 2,382 2,481 SCHEDULE 40 EDDY FLOW 1 3.660 2.809 30 2,306 1,770 2,635 2,022 2.745 2,107 [ 2-1/2 SCHEDULE 10 3.530 30 2,224 2,542 2,648 SCHEDU1E40 EDDY FLOW' 5.800 3.361 3,654 1,341 4.176 1,533 4.350 1,596 E 1 3 SCHEDULE 10 4.340 19 1,732 1,979 2,062 . SCHEDULE 40* 7.580 3.024 3,456 3.601 EDDY FLOW' 4.968 1,982 2,265 2,360 4 rSCHEDULE1O 5.620 19 2,242 2,563 2,670 SCHEDULE4O SCHEDULE 10 AZ. 10.800 9.289 16.940 10 7 4,309 1,951 2,490 4,925 2,229 2,846 5,130 2,322 2,965 [ 8 j * Only Available in Casa Grand Bull Moose Tube EDDY FLOW Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) *** According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30f1. 35 ft. 40 ft. 0.25 0.50 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 11/4 136 109 89 76 64 40 40 37 32 29 26 24 23 21 20 19 18 1 1/2 232 185 152 130 109 40 40 40 35 31 29 27 25 23 22 21 20 2 372 297 244 209 175 1 40 40 40 38 34 31 28 27 25 24 23 22 21/2 549 440 360 309 258 40 40 40 40 36 32 30 28 26 25 24 23 3 809 648 531 455 381 40 40 40 40 37 34 31 29 28 26 25 24 4 1 1544 1 1235 1 1012 1 867 726 40 1 40 1 40 1 40 40 37 34 32 30 1 29 1 28 26 Bull Moose Tube EDDYTHREAD 40 Steel Pipe Joined by Threading, Bonding or Compression/Grooved Couplings MaxZone of Influence Load (Fpw) lbs. Max. Transverse and 4-way Brace Spacing (ft.) According to HLF for the 2006 & 2009 IBC (ASCE 7-05 ) & Cp for NFPA-13 shown in BOLD TYPE Pipe Transverse Brace Spacing Size 20 ft. 25 ft. 30 ft. 35 ft, 40 ft. 0.25 0.50 1 0.75 1.00 1.25 1.50 1.75 2.00 2.25 2.50 2.75 3.00 1 119 95 78 67 56 40 40 36 31 28 25 24 22 21 20 19 18 11/4 218 175 143 123 103 40 40 40 35 31 28 26 25 23 22 21 20 11/2 312 250 205 175 147 40 40 40 37 33 30 28 26 25 23 22 21 2 518 414 339 291 243 40 40 40 40 36 33 30 29 27 26 24 23 euLL MOOSE TUBE COMPANY 1819 Clarkson Road Chesterfield, MO 63017 PHONE: (800) 325-4467 FAX: (636) 537-2645 www.bullmoosetube.com sales@bullmoosetube.com c®us LISTED APPROVED 14-1 ONFSA NFPX --- () A For Additional Information Contact (800) 325-4467 www.bullmoosetube.com Or From Canada Call: (800) 882-4666 sales@butlmoosetube.com U 1819 Clarkson Road Chesterfield, MO Gerald, MO Kent, WA Casa GrandR AZ Dallas, TX Masury, OH 63017 11 MechanicaIT® STYLES 920 AND 920N Victaulic Mechanical-I® Outlet provides a direct branch connection at any location a hole can be cut in pipe. The hole is cut oversize to receive a holefinder" locating collar which secures the outlet in position permanently. A pressure responsive gasket seals on the pipe O.D. Cross-type connections can be achieved by utilizing two upper housings of the same style and size, with the same or differing branch size connections. NOTE: Style 920 and Style 920N housings cannot be mated to each other to achieve a cross connection. Style 920 and Style 920N Mechanical-T outlets are available with grooved or female threaded outlet. Specify choice on order. Units are supplied painted with plated bolts. Galvanized hous- ings are available, supplied with plated bolts. All sizes of Style 920 and 920N are rated at 500 psi/3450 kPa working pressure on Schedule 10 and 40 carbon steel pipe. They may also be used on high density polyethylene or poly- butylene (HDPE) pipe. Pressure ratings on HDPE are dependent on the pipe rating. Contact Victaulic for ratings on other pipe. Style 920 and 920N are not recommended for use on PVC plastic pipe. Standard piping practices dictate that the Mechanical-T Styles 920 and 920N must be installed so that the main and branch connections are a true 900 angle when permanently attached to the pipeline surface. Additionally, the Vic-Tap Il® hole cutting tool, which allows for hole cutting capabilities on pressurized systems, utilizes the Style 920 Mechanical-T in conjunction with the Series 726 Vic-Ball Valve to create the Style 931 Vic-Tap II Mechanical-I unit. See page 8 for further information. 4 1 STYLE 920 CROSS PATENTED STYLES 920 AND 920N MATERIAL SPECIFICATIONS Housing/Coating: Ductile iron conforming to ASTM A-536, grade 65-45-12, with orange enamel coating. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Optional: Hot dipped galvanized Gasket: (Specify choice*) Grade "E" EPDM EPDM (Green color code). Temperature range —30°F to +230°F/-34°C to +110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/-i-82°C. NOT RECOMMENDED FOR PETROLEUM SERVICES. Grade T" nitrile Nitrile (Orange color code). Temperature range —20°F to +180°F/-29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not recommended for hot water services over +150°F/+66°C or for hot dry air over +140°F/+60°C. *Services listed are General Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com ictaulice vIclAuLic IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 vicTAuLic COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_i DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1h'/50 x 15 mm through 8 x 4/200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N Max.Workl Approx. SJflh1;.lfl. Weight Each 2716 .Pressure@ . aG • " - - 920N 500 1.50 200 2.53 , 1.61 5.35 275 3.1 50 15 3450 38.1 j, 51 64 - 41 136 70 1.5 - ~ (a) 920N 500 1,50 1.97 2.53 1.61 5.35 2.75 3.1 20 3450 38.1 50 64 - 41 136 70 1.5 - 1(a) 0 920N 500 1.50 1.85 2.53 1.61 5.35 2.75 t 3.0 25 3450 t 38.1 47 64 - 41 136 70 1.4 - 11/4 (a) to 500 1.75 2.05 2.75 3.00 1.61 5.35 3.00 3.5 3.2 32 920N 3450 --,-t 44.5 1 52 -+- 170 76 .- 41 -+- 136 76 -±- 1.7 1.5 1½ (a) to 920N 500 1.75 2.03 2.75 3.12 1.61 I 5.35 3.25 3.6 3.2 40 500 920N 1.50 2.21 2.74 1.82 5.64 2.75 1.7 3.0 1.5 . 21/2 ½ (a) §n 65 15 3450 38.1 56 .. 70 - 46 --...........-- 143 70 1 1.4 - 4/4 (a) ° 920N 500 1.50 2.18 2.74 1.82 5.64 2.75 3.0 20 3450 381 5570 - 46 143 70 1.4 -. 1(a) §0 920N 500 1.50 2.06 1 2.74 1.82 5.64 2.75 2.9 25 -. 3450 38.1 52 jJ.2 46 3 0 1.4 1.75 11/4 t (a) a 500 920N 2.30 3.00 3.25 1.82 6.29 3.00 1 3.5 3.2 32 3450 44.5 58 76 83 - 46 160 +- 76 -+- I 1.7 1.5 1½ 1(a) 0 920N 500 2.00 2.28 1 3.00 3.25 1.82 I 6.26 3.25 1 3.6 3.3 40 3450 920N 300 50.8 1.50 58 2.22 76 t 2.75 83 46 ,J_12, 83 1.7 1.6 761 x 1/2 (a) 2.25 j 6.46 15 2065 38.1 1 56 70 - 57 164 81 1.8 - 3/4 (a) 920N 300 1.50 2.19 1 2.75 2.25 6.46 3.18 T .9 20 2065 38.1 56 70 - 57 164 81 1.8 - 1 (a) 920N 300 1,50 2.07 2,75 2.25 6,46 3.18 3.8 25 2065 38.1 53 20_ .__57 164 L 1.7 1¼ (a) 0 32 920N 500 1,75 44.5 2.30 58 3.00 76 1.92 3.5 1.6 3.2 1.5 3.31 84 49_Jj, I 6.29 3.00 _76 _j 1112 (a) 0 920N 500 2.00 1' 2,28 3.00 3.31 1.92 6,29 3.25 3.5 3.3 40 3450 920N 500 j 50.8 1.50 58 2.52 76 3.05 84 49 2.28 160 6.15 83 2.75 1.6 1 3.4 1.5 3 x 1/2 (a) a 80 15 3450 38.1 64 78 ' 58 156 70 j, 1.6 - 'A (a) a 920N 500 1.50 2.49 3.05 2.28 6.15 2.75 3.4 20 , 3450 j 381 63 78 - 58 156 70 1:6 - . 1(a) 920N 500 ) 1.50 2.38 3.06 2.28 6.15 2.75 33 25 13450 381 6178 58 156 70 J 1.6i 1.75 44.5 2.55 1 65 3.25 83 1¼ (a) to 32(b) 920N 500 3450 3.56 90 2.28 58 6.15 156 3.00 76 3.8 1,8 3.7 1.8 1½ (a) '° 920N 500 1 2.00 2.78 3.50 3.56 2.28 6.15 3.25 T 4.1 3.8 40(b) - 3450 50 , 2.50 3.50 2 (a) n 920N 500 2.75 3.56 2.28 6.75 3.88 4.9 4.6 50 3450 920N 500 63.5 2.50 70 ,j, 3.00 89 90 3.75 58 2,44 172 6.72 99 3.88 2.3 2.1 3.8 3½ 2 90 50 3450 63.5 76 - 95 62 171 99 1,8 TABLE CONTINUED ON PG. 3 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). 1 Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services o LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com '49ctaUliC vicTAuLic IS REGISTERED TRADEMARK oFvIcTAuLIc COMPANY. 02017 VICTAUUC COMPANY. ALL RIGHTS RESERVED, 11.022 REVN DIMENSIONS 11 -8 14" 'bS I-61111FA GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x 1050 x 15mm through 8 x 47200 x 100 mm CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N Si-'e Styl Noe essure@ Dimensions Kam I sm TABLE CONTINUED FROM PAGE 2 4 1h (a) n 920N I 500 1.50 3.03 3.56 2.69 7.01 2.75 I 3.7 100 15 j 3450 381 77 90 - 68 1 178 70 - 1.8 500 3/4 (a) ' 920 N 1.50 3.00 3.56 2.69 7.01 2.75 3.7 20 3450 38.1 I 76 90 - 68 178 70 - 1.8 1(a) a 2.88 3.56 2.69 7.01 .- 2.75 3.6 500 1.50 25 ) 3450 t ...-- 38.1 - 73 - 90 - - + 68 178 ._.. 70 - 1.8 1¼ (a) 'r 920N ) 500 1.75 3.08 3.78 4.00 2.69 7.01 3.00 4.0 . 3.6 32(b) ,3450 44,5- I2.i12 500 2.00 1 1h (a) •j•a 920N 3.28 4.00 4.00 2.69 7.01 3.25 4.2 3.9 40(b) -. 3450 50.8 ., L 12 . JL L),ZL _3 ..1.2.0.. 11. 500 2(a) to 920N 2.50 1 3.25 4.00 4.00 2.69 7.01 3.88 1 5.0 4.6 50 3450 63.5 ) 83 102 102 68 178 99 2.3 2.1 21h (a) t 920 500 2.75 2.88 4.00 4.00 2.69 1 7.34 4.63 5.8 5.0 65 3450 ) 69.9 73 102 102 68 186 118 2.6 2.3 + -'--- f - -i - - mm 500 2.75 - 76.1 * 2.88 4.00 2.69 7.34 4.63 6.4 3450 69.9 73 102 68 186 118 - 2.9 500 3(a) t 920 3.50 3.31 4.50 4.12 2.69 7.73 5.12 8.4 6.4 80 3450 j 84 j [ 10568 196 130 18 . 2.9 500 , 1.75 ) 3.08 3.78 11/4 (a)o 108.0 x N 2.63 7.64 3.05 5.0 32 3450 I 44.5 78 96 - I 67 i 194 78 - 2.3 11/2 (a)a 500 -I---- 2.00 f 3.28 -+-.. 4.00 - -+- 2.63 7.64 - 3.25 - + 5.0 40 3450 50.8 I 83 102 - 67 194 83 - 2.3 2(a) ) 2.50 3.25 4.00 * 2.63 7.64 4.00 + 4.0 500 50 3450 J, 63.5 83 102 - 67 194 102 - 1.9 76.1 mm - 500 2.75 -1---- 2.88 ..-.-.- 4.00 .--.,-.--_-- 2.63 7.64 ,- 4.29 8.0 ' 7.8 -'-'-'---'- 4.00 3450 69.9 73 102 102 67 194 109 3.6 3.5 3 (a) 920 500 1 3.50 3.31 4.50 4.50 2.63 7.63 4.88 6.8 6.5 80 - 920 3450 500 88.9 2.00 84 4,03 114 4.75 -'r 114 4.75 67 194 124 31 j 10 7.4 7.6 5 1½ (a) t 3.16 9.70 3.69 125X40 2 (a) t 500 2.50 4.00 4.75 4.75 3.16 9.70 4.38 8.2 8.0 50 920 3450 63.5 102 121 121 80 246 111 3.7 3.6 920 500 3450 2.75 69.9 3.63 92 4.75 121 j, 21h (a) t 65 4.75 121 3.16 9.70 80 1 246 4.63 118 8.3 7.9 3.8 3.6 3.75 3.16 9.70 4.63 8.0 920 3450 500 2.75 4.75 76.1mm', 69.9 95 121 i. - . . - 3(a) t 920 500 3.50 3.81 5.00 4.63 I 3.16 1 9.70 5.31 8.4 . 8.8 80 920N 3450 500 88.9 , 2.50 97 3.75 127 4.50 118 80 1 246 3,17 '' 8.00 135 3.88 3.8 ,j 4.0 8.0 2 133.0 X 50 3450 1 63.5 95 114 81 1 203 99 - 3.6 8.0 920 500 3.50 3.81 5.00 3.00 9.46 5.31 80 3450 88.9 97 127 - 76 240 135 - 3.6 TABLE CONTINUED ON PG. 4 IMPORTANT NOTES: 4* Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). Style 920 and Style 920N housings cannot be f Available with grooved or female threaded outlet. Specify choice on order. mated to one another * Center of run to end of fitting. to achieve cross connections. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF ViCTAULIC COMPANY. © 2017 VICTAuLIc COMPANY. ALL RIGHTS RESERVED. \Atauliie REV_N 11.02_3 CARBON STEEL PIPE HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi/3450kPa on steel pipe; also available for use with HDP[ pipe Sizes from 2 x 1/2 /50 x 15mm through 8 x 47200 x 100 mm IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to one another to achieve cross connections. Weight Each iflT jT i TABLE CONTINUED FROM PAGE 3 1397 1½ 1' 920N 500 2.00 I 3,78 4.50 3.30 8.23 3.25 7.0 40 3450 50.8 96 114 - 84 209 83 3.2 - 2t 920N 500 , 2.50 3.75 4.50 3.30 I 8.23 3.88 9.0 50 920N 500 I 63.5 1.75 95 4.43 114 5.13 .3450 22. 5.13 84 209 3.79 9.15 3.25 J. 5.1 4.8 6 1 ¼ (a) < 150 32(b) 3450 J 44.5 112 130 130 96 83 2.3 2.2 11/2 (a) to 920N 500 2.00 4.40 5.13 5.13 3.79 9.15 3.25 5.4 51 40(b) 3450 50.8 112 130 130 96 232 83 2.4 2.3 2(a) to 92014 500 2.50 4.38 5.13 3.79 9.15 3.88 6.0 5.6 5.13 50 3450 1 63.5 111 130 130 96 _232 99 2.7 2.5 2½ 920 2.75 4.01 5.13 5.12 3.69 I 10.51 4.63 8.3 7.6 500 65 3450 ,[ 69.9 110 130 130 94 267 118 3.8 3.4 761 mm a 920 500 2.75 4.15 - 5.21 3.69 10.51 4.63 - 8.4 3450 69.9 105 132 94 267 118 3.8 4.31 3(a) t 920 500 3.50 5.50 5.13 3.69 10.51 5.31 9.9 8.4 80 3450 88.9 110 140 130 94 267 135 , 4.5 3.8 4 (a) to 920 500 I 4.50 3.81 5.75 5.38 3.69 10.51 6.25 10.1 10.1 100 -. 920N 345O41143 500 97 4.41 146 137 94267 3.63 9.40 I 3.25 159146 4-6 7.8 1 ½ (a) 59.0 < 2.00 5.13 40 °_ . . 239 I .. .! -. 2 (a) 920N 500 2.50 4.38 5.13 3.63 9.40 3.88 8.0 50 3450 63.5 111 130 - 92 4 239 99 3.6 - 4.38 5.50 76.1 MM 920 500 2.75 5.13 3.63 9.40 4.63 9.5 9.5 3450 69.9 111 140 130 92 239 118 4.3 4.3 920 500 3.50 4.31 5.13 -_4_- 3.63 9.40 - 5.31 -_ 8.1 * 14.0 5.50 80 3450 88.9 110 140 130 92 1 239 1 135 3.7 6.4 108.O mm mm 2 0 500 4.50 4.45 5.38 3.63 1 9.40 6,12 10.0 , 3450 1114.3 113 - 137 92 L 239 155 - 4.5 500 920 4.50 3.81 5.75 3.63 9.40 6.25 18.0 100 3450 114.3 96.80 146 - 92 239 159 8.2 - TABLE CONTINUED ON PG. 5 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. $ Center of run to end of fitting. 8 Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings. (a) British Standard female pipe threaded outlet is available as listed. Specify "BSPT clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2' BSPT clearly on order. § Vds approved for fire protection services LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. www.victaulic.com ctaUlic VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_4 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N DIMENSIONS 6ff -1-1tif GROOVED OUTLET FEMALE THREADED OUTLET Provides a direct branch connection at any location where a hole can be cut in the pipe A pressure responsive gasket provides the seal Request Publication 11.03 for Mechanical-T cross assemblies Pressure rated up to 500 psi 13450 kPa on steel pipe; also available for use with HDPE pipe Sizes from 2 x W/50 x 15mm through 8 x 47200 x 100 mm Dimensions TABLE CONTINUED FROM PAGE 4 1651 1 920N 500 1.50 3.88 4.56 I 3.79 9.34 2.75 8.0 - 25 3450 381 99 116 96 * 237 70 3.6 I,/,a 32 920½ 500 j 3450 1.75 44.5 4.43 113 5.13 130 1 - 3.79 9.34 96 237 3.25 8.4 83 3.8 - ±* t*, - 500 - 2.00 11/2 lal to 920N 4.41 I 5.13 1 5.13 3.79 9.34 3.25 8.4 5.4 40 3450 50.8 112 130 130 96 237 83 3.8 2.4 500 2 (a) t 920½ 2.50 4.38 5.13 1 5.13 3.79 9.34 3.88 8.5 6.0 50 3450 63.5 Ill L130 i 130 96 237 99 3.9 2.7 76.1 mm 920 500 3450 2.75 I 69.9 4.01 110 513 130 j 5.21 132 3.63 10.51 92 267 4.63 8.6 7.6 118 3.9 3.4 - -±- --+-. -- -f.- -- 3(a) t o 920 500 j 3.50 4.31 5.50 j 5.13 3.63 10.51 5.31 10.2 8.4 80 3450 88.9 110 140 I 130 92 267 135 4.6 3.8 500 4 (a) to 920 4.50 3.81 5.75 5.38 3.63 10.51 6.25 10.5 8.4 100 92 500 2.75 5.44 6.19 6.25 4.81 12.42 .. J1 4.50 11.6 11.6 8 2(a) t 200X50 21/2 (a) t 3450 500 69.9 2.75 138 5.07 157 6.19 IL9 6.19 2~ 4.81 12.42 4.50 11.6 ' 11.6 920 65 40 69 9157j 157 122 1 316 JJ± 76.1 mm 9 0 2 500 2.75 5.25 6.25 4.81 j 12.42 4.56 11.6 - 3450 - 69.9 - 133 - - -- 159 122 316 - - 116 5.3 500 3.50 3(a) l 920 5.31 6.50 6.50 4.81 12.42 t 5.31 12.6 11.6 80 40 .........................65 i J_ 4 (a) I-a 920 500 4.50 4.81 6.75 6.38 4.81 12.42 6.25 15.3 12.5 100 3450 114,3 122 171 162 122 316 159 6.9 I 5.7 Center of run to engaged pipe end, female threaded outlet only (dimensions approximate). t Available with grooved or female threaded outlet. Specify choice on order. * Center of run to end of fitting. # Female threaded outlets are available to NPT and BSPT specifications. @ See page 7 for Fire Protection approvals and pressure ratings.' (a) British Standard female pipe threaded outlet is available as listed. Specify BSPT" clearly on order. (b)For 76.1 mm threaded outlet, specify 21/2" BSPT clearly on order. § Vds approved for fire protection services a LPCB approved for fire protection services 0 Approved for use in China by Tianjin Approvals Company. IMPORTANT NOTES: Style 920 and Style 920N housings cannot be mated to each other to achieve cross connections. www.victaulic.com A-Ctnuliiie vIcTAuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 2017 vICTAuuc COMPANY. ALL RIGHTS RESERVED. REVN 11.02_5 CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-T® Bolted Branch Outlets STYLES 920 AND 920N FLOW DATA Flow test data has shown that the total head loss between point (1) and (2) for the Style 920, 920N and 929 Mechanical-TO fittings can best be expressed in terms of the pressure difference across the inlet and branch. The pressure difference can be obtained from the relationship below. Cv and Ky Values Values for flow of water at +60°F/+16°C are shown in the table below. Exaggerated for clarity Formulas for Cv ,K Values: = Where: Q = Flow (GPM) AP = Pressure Drop (psi) Q = C x JAP CV = Flow Coefficient AP = Q2 Where: 0 = Flow (m3/hr) AP = Pressure Drop (Bar) 0 = K, x K = Flow Coefficient OUTLET SIZE Equivalent Outlet Size 40 Carbon Length of Schedule Steel Pipe Lifll•i4. 11 ½ 0.840 15 21.3 - 2 - 9.4 Y4 1.050 16 20 I .26L . ..-._.-..-.--1.- 1 1.315 21 25 337 .. 8 -1.8 1 ¼ 1.660 50 48 32 42.7 5 6 42.9 41.1 1 ½ 1.900 11 11 53 53 40 98.3 45.4 45.4 2 2.375 r 112 104 50 §Q3L 9 10½ 96 89.1 2½ 2.875 119 150 65 73.0 20 1216 4. 102 128.5 3.000 76.1 mm 16 - 161 761 . 3 3.500 249 237 80 88.9 14 15½ 213.4 203.1 4 4.500 421 401 100 114.3 20 22 360.8 343.6 Hazen-Williams coefficient of friction is 120. Pipe with a wall thickness of 0.1651ni4.2mm. r FireLock Innovative Groove System (lGS) outlet www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. \Actaulie 11.026 REV_N CARBON STEEL PIPE - HOLE CUT PRODUCTS 11.02 Mechanical-I® Bolted Branch Outlets STYLES 920 AND 920N FIRE PROTECTION APPROVALS AND PRESSURE RATINGS The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Run Size Outlet Size j ________ Pipe -Ilk Approval Agency Rated Working Pressures — psi/kPa 21/2 -6 2.875 - 6.625 All 10,40 400 400 400 F 290 I 232 362 65-150 73.0-168.3 2755 2755 2755 1999 1599 1 2496 21/2 - 4 2.875 - 4.500 All DF 300 300 300 290 232 362 65-100 73.0-114.3 - 2.875 - 4.500 All - SF 2065 300 2065_i 300 2065 - 1 300 1999 . 290 232 1 .2_. _L2_ I 362 21/2-4 65-100 73.0-114.3 6.625 3,4 10 2065 300 2065 300 1 2065 250 1999 290 1599 232 2496 362 6 150 !4 L.. 6.625 34 3040 2065 300 300 2065 1724 I 300 1999 290 1599 232 2496 362 6 150 - 168.3 - _'_ -- 8.625 21/2 10,40 2065 I 400 - 2065 1999 1599 145 2496 - - 8 200 21 8.625 4 10 j 2755 300 - I 250 - 1000 145 - 8 200 219.1 8.625 34 3040 2065 300 - - 1724 300 - j 1000 145 - 8 200 219.1 2065 2065 - 1000 - NOTES: 10 refers to Listed/Approved Schedule 10 steel sprinkler pipe. 40 refers to Listed/Approved Schedule 40 steel sprinkler pipe. DF refers to Listed/Approved Dyna-Flow steel sprinkler pipe manufactured by American Tube Company. SF refers to Listed/Approved Super-Flo steel sprinkler pipe manufactured by Allied Tube and Conduit Corporation. VIC-TAP II HOLE CUTTING TOOL FOR The Vic-Tap II hole cutting tool is designed for use with the Style 931 Vic-Tap II Mechanical-T unit, 4- 87100 - 200MM CARBON STEEL PIPE which is a combination of the Style 920 Mechanical-T and Series 726 Vic-Ball Valve. The Vic-Tap II is capable of tapping into carbon steel pipe systems under pressures up to 500psi/345OkPa. The Style 931 Vic-Tap II Mechanical-T unit is a full port ball valve which can be mounted on 47100mm, 5/125mm, 6/150mm and 8/200 mm diameter pipe. The Style 931 comes with a 21h'I65mm grooved outlet. The drill motor is an electric motor with ground fault circuit interrupter (GFCF) in accordance with safety codes. For more information, refer to publication 24.01. www.victaulic.com \$taUIic vIcTAuuC IS A REGISTERED TRADEMARK OF vICTAuLIC COMPANY. 0 2017 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. REV_N 11.02_7 MechanicaIT® STYLES 920 AND 920N INSTALLATION Reference should always be made to the -100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 11.02 1480 REV N UPDATED 1212017 ictsulie viciuuc IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2017 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 11.02_L FireLock® STYLE 922 Para JOB/OWNER System No. Location CONTRACTOR ENGINEER Submitted By Spec Sect Date Approved The Style 922 Outlet-T provides a convenient method of incorporating ½, 3/4, and 1/15, 20 and 25mm outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products. Available for 114 through 76.1 mm132 to 76.1 mm piping systems, Style 922 outlets are ULIULC Listed, LPCB and FM Approved for branch connections and VdS Approved for direct sprinkler connection only on wet and dry systems. The locating collar engages into the hole prepared in the pipe. When tightened, the assembly compresses the gasket onto the OD of the pipe. The Style 922 Outlet-T is UL/FM rated up to 300 psi/2068 kPa and VdS rated up to 16 bar at the ambient temperatures typical for fire protection systems. Style 922 is suitable for use on standard, lightwall, Schedule 5 and other specialty pipes.* Contact Victaulic for other optional coatings. *Consult Section 10.01 for specific listings/approvals MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Gasket: Grade "E" EPDM - Type A (Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc. and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services up to the rated working pressure using the Grade "E" Type A Gasket System. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. Housing Coating: Orange enamel (North America, Latin America, Asia Pacific) Red enamel (Europe) Date www.victaulic.com vICTAuLIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. Q 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G ,%tauIicr 10.52_i FireLock® Outlet-T STYLE 922 DIMENSIONS 'p •u ..' • IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 1052 WF 14 1h 13Ao 130 1.83 1.10 3.87 2.56 1.0 32 15 30.2 33.0 46,5 27.9 98.3 65.0 0.45 '/4 13A6 1.28 1.83 1.10 3.87 2.56 1.1 20 30.2 32.5 1 46.5 27.9 98.3 65.0 0.50 + 1 13A6 1,52 2.18 1.10 3.87 2.56 1 1.2 25 30.2 13A6 38.6 1.42 55.4 1.95 27.9 --- 1.22 98.3 V 4,08 65.0 2.56 1 I 0.54 - 1.2 1½ ½ 40 15 30.2 36.1• 49,5 31.0 103.6 65.04 0.54 F 3/4 1/io 1.40 1.95 1.22 4.08 2.56 1.2 20 30.2 - 35.6 49.5 31.0 103.6 65.0 0.54 41, 1 13A6 1.64 2.30 1.22 4.08 2.56 1.3 25 30.2 13!6 41.7 1.66 58.4 2.19 , 31.0 1.46 103.6 4.60 65.0 2.56 , 0.59 1.3 2 x 1/2 50 15 30.2 42.2 1, 55.6 37.1 j 116.8 65.0 0.59 , T 3/4 1/6 1.64 2.19 1.46 4.60 2.56 1.4 20 30.2 41.7 , 55.6 37.1 116.8 65.0 1 0.64 1 1/6 1.88 2.54 1.46 4.60 2.56 1.5 25 30.2 1,16 47.8 1.91 t64.5 2.44 371L 1.71 116.8 5.40 65.0 2.56 0.68 1.6 2½ x ½ 65 15 30.2 , 48.5 62.0 43.4 137,2 65.0 , 013 1/4 13/16 1.89 2.44 1.71 5.40 2.56 1 1.6 20 30.2 48.0 62.0 43.4 137.2 65.0 0.73 1 1 3A6 2.13 1 2.79 1.71 5.40 2.56 1.6 25 30.2 1 3A6 54.1 1.91 1 70.9 2.44 43.4 1.71 137.2 5.50 65.0 2.56 0.73 1.6 ½ 76.1 mm X s 19.2 48.5 .4 620 4+4 1376+0 4 013 3/~ 1 V16 1.89 2.44 2.56 1.6 20 30.2 4+0 I 62.0 414 j 1 2.79 1.71F5.50 1 1 3/16 2.13 1.71 2.56 1.7 25 30.2 54.1 70.9 43.4 65.0 0.80 t Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Use of male threaded products with special features, such as probes, dry pen- dent sprinklers, etc., should be verified as suitable for use with this Victaulic product. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. C 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 1O.52_2 1htauiic REV_G IPS CARBON STEEL PIPE - HOLE CUT PRODUCTS 10.52 FireLock® Outlet-T STYLE 922 PERFORMANCE Run Sizex liihes/n,m - Outlet Size - Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)*, FT F6Pt/iitter 8.5 8.5 2.6 8.5 2.6 8.5 2.6 85 1 Hazen-Williams coefficient of friction is 120 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2009 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_G 4tauiicr 1O.52_3 FireLock® STYLE 922 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.52 3355 REV G UPDATED 12/2009 ictaulic viciuic IS REGISTERED TRADEMARK OF vicTAuLic COMPANY. 192009 vIcTAULIc COMPANY. ALL RIGHTS RESERVED. 10.52 :- $ T 4. -.!Iu a Li Ductile Iron Threaded Fittings SMITHSCOOPER® INTERNATIONAL Ductile iron Threaded Fittings - Specifications branded ductile iron th'eaded fittings we UL Listed and FM Approved at 50C psi Rated to 300 WSP Iii. Ducthe iron castings conform to ASTM A53€ C Us LISTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 < > Fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & physical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 Temperature Degrees F Working Pressure, Nonshock psiG 300 Class Threaded Fittings -20 to 100 500 150 - 500 200 480 250 460 300 440 350 -- 420 400 400 450 380 500 360 550 340 600 320 650 300 Fig. 35E 3_900 Elbow c®US <~> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35E 3004 1.13 100 200 0.2 3/4 - 35E 3006 - 1.31 70 140 0.3 1 35E 3010 1.50 40 80 0.5 1-1/4 35E3012 1.75 25 50 0.8 1-1/2 35E3014 35E3020 1.94 18 36 1.1 2 2.25 10 20 1.8 2-1/2 35E3024 2.70 4 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in - B in Packing Weight lb Inner Master 3/4x1/2 35RE3006004 1.20 1.22 80 160 0.3 1x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1x 3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4 x 1/2 35RE3012004 1.34 1.53 35 - 70 0.5 1-1/4x 3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x 3/4 35RE3014006 152 1.75 25 50 0.7 1-1/2x1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2x1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2x1/2 35RE3020004 1.60 1.97 18 36 1.0 2x 3/4 35RE3020006 1.60 1.97 18 36 1.0 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 1.90 2.10 12 24 1.3 2x1-112 35RE3020014 2.02 2.16 10 20 1.5 x1-1/2 35RE302414 - 2.16 2.51 6 12 2.2 2-1/2x 2 35RE3024020 2.39 2.60 1 6 12 2.5 1! Fig. 35F3 - 45° Elbow Size in Part Number A in Packing Weight lb Inner Master 1/2 35F 3004 0.88 150 300 0.2 3/4 35F3006 35F 3010 0.98 80 160 0.3 - 1 1.13 40 80 0.5 1-114 • 35F 3012 1.29 25 50 07 1-1/2 35F 3014 35F 3020 1.44 1 20 40 1.0 2 1.69 10 -20 1.6 2-1/2 35F3024 1.95 1 4 8 2.7 Fig. 35T 3- Tee Size in Part Number a u er A in Packing Weight lb Inner Master 1/2 35T 3004 1.13 80 160 0.3 3/4 3513006 1.31 30 60 0.5 1 3513010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1.1 1-1/2 35T3014 1.94 10 20 1.5 2 35T 3020 2.25 6 12 2.4 2-1/2 35T 3024 2.70 4 8 4.3 111 SMITH-COOPER INTERNATIONALS • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • wwwsmithcooper.com Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4 x 1/2 35R13006004 1.20 1.20 1.22 60 120 0.4 1 x 1/2 35R13010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 -- 1 x3/4 1 x3/4x3/4 35R13010006 1.38 1.38 1.45 25 50 70 0.6 35RT3010006006 1.38 1.31 1.45 35 0.6 1 x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4 x1/2 35R13012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35R13012004012 1.75 1.53 1.75 25 50 0.9 i-1/4x3/4 35RT3012006 1.45 1.45 1.62 15 30 0.9 1 1/4 x3/4x1 1/4 35R13012006012 175 162 175 20 40 10 i-1/4x1 35RT3012010 1.58 1.58 1.67 15 25 30 50 1.0 0.7 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 1-1/4 x1x3/4 35R13012010006 1.45 1.38 1.63 20 20 40 0.8 1-1/4x lxi 35R13012010010 1.58 1.50 1.69 40 0.9 1-1/4x1x1-1/4 35RT3012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35RT3014004014 1.94 1.66 1.94 12 24 1.2 i-1/2x3/4 35R13014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-i/2 35RT3014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 35RT3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35R13014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x3/4 35RT3014010006 1.50 1.44 1.75 16 32 0.9 1-1/2x1x1 35R13014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35RT3014012 1.82 1,82 1.88 12 24 32 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16 0.9 1-1/2x1-1/4x3/4 35R13014012006 1.52 1.45 1.75 16 16 32 32 1.0 1.1 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-112 35R13014012014 1.94 1.88 1.94 14 28 20 1.4 1.5 2 x 1/2 35RT3020004 1.49 1.49 1.88 10 - 10 8 2x3/4 - 35R13020006 1.60 1.60 1.97 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-i/4 35RT3020012 190 1.90 2.10 8 16 1.9 2x1-1/4x2 2x1-1/2 35R13020012020 2.25 2.10 2.25 8 16 2.0 2.1 35RT3020014 2.02 2.02 2.16 8 16 20 2x1-1/2x1/2 35R13020014004 1.49 1.41 1.88 10 1.3 2x1-1/2x3/4 35RT3020014006 1.60 1.52 1.97 10 - 16 201.4 1.5 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 2x i-1/2x1-i/4 35R13020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 35RT3020014014 2.02 1.94 2.16 8 16 1.8 U C T L E C@ us <e> APPROVED Fig. 35RT3 - Reducing Tee LISTED Fig. 358T3 - Bull Head Tee Size in Part Number A in B in C in Packing I Weight I lb Inner I Master 3/4x1 35B13006010 1.45 1.45 1.37 30 20 - 60 0.6 1 x 1-1/4 35BT3010012 1.67 1.67 1.58 40 0.9 1 x 1-1/2 35B13010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-1/2 1-1/4x1-1/2 35BT3012010014 1.88 1.80 1.82 15 30 1,2 35B13012014 1.88 1,88 1.82 15 30 1.3 1-1/4x2 35B13012020 2.10 2.10 1.90 10 20 16 1-1/2x1-1/4x2 35813014012020 2.16 2.10 2.02 10 8 20 16 1.8 1.8 1-1/2x2 35BT3014020 2.16 2.16 2.02 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 112 Fig. 3503 - Straight Coupling with Ribs c®uS <e> APPROVED LISTED Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 203 400 0.1 3/4 35CP3006 1.63 100 200 - 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 - 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1 1.2 2-1/2 35CP3024 3.00 18 2.2 Size in Part Number A in Packing Weight lb Inner Master lx 1/2 35RC3010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 0.4 1-1/4 x 3/4 35R03012006 2.06 40 80 0.6 2x 1 (not hex)l 35RC3020010 2.81 1 20 40 1 1.0 Size in Part Number A in Packing Weight lb Inner Master 1/2 35SP3034 0.94 600 1200 0.07 3/4 35SP3006 1.12 350 700 0.1 1 35SP3010 1.25 203 403 0.1 1-1/4 35SP3012 1.37 1 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.53 45 90 0.6 Fig. 35RC3 - Hex Reducing Coupling Fig. 35HB3 - Hex Bushing Size in Pad Number A in Packing Weight lb Inner Master 1 x 1/2 35H83010004 1.06 180 360 0.2 1x3/4 35H83010306 1.06 180 360 0.1 1-1/4x1 35HB3012010 1.19 90 180 0.2 1-1/2x1 35H83014010 1.25 75 150 0.4 1-1/2x1-1/4 35HB3014312 1.25 75 1 150 0.3 2 x 1 35HB3020010 138 40 1 80 06 2x1-1/4 35HB3020012 1.38 43 80 0.6 2 x 1-1/2 35HB3020014 1.38 40 80 0.6 Fig. 355P3 - Square Head Plug Fig. 35U 3- Union with Brass Seat Size in Part Number A in Packing Weight lb Inner Master L. 35U 3010 2.19 20 43 1.0 35U 3012 2.50 15 30 - 1.2 - 1-1/2 35U 3014 2.62 10 20 1.7 2 35U 3020 3.12 6 12 2.4 113 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com A A Size in Part Number A in Packing Weight lb Inner Master 35X 3010 1.50 1.75 20 12 40 0.9 1-1/4 35X3012 24 1.4 1-1/2 35X3014 1.94 8 - 16 1.8 2 35X 3020 2.25 1 6 - 12 2.8 Iiui1 Size in Part Number A in Packing Weight lb Inner Master 1/2 35C 3004 0.87 300 600 0.1 3/4 -3503006 0.97 200 - 400 0.1 1 3503010 1.16 110 220 0.2 _________ 1-1/4 3503012 1.28 - 70 140 1-1/2 35C3014 1.33 50 100 - 0.5 -2 35C 3020 1.45 25 50 0.8 2-1/2 35C 3024 1.70 18 36 1.6 Fig. 35BC3 - Beam Clamp c®US <e> APPROVED A A Fig. 35X 3- Cross LISTED Fig. 35RX3 - Reducing Cross I Size ' I in I Part Number I I A I . I in I B i in I Packing I Weight I lb I Inner I Master I 1-1/4x1 I 35RX3012010 I 1.67 I 1.58 I_15 I 30 I 1.2 I 1-1/2x 1 35RX3014010 I 1.80 1.65 I 12 24 16 11.4 2.0 2 x 1 35RX3020010 2.02 I 1.73 8 Fig. 35C 3- Cap Size in Part Number A in Packing Weight lb Inner I Master 3/8 35B03003 0.75 100 200 0.3 1/2 35B03004 0.75 80 160 0.5 SMITH-COOPER INTERNATIONAL • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 114 INSTALLATION STEPS -%@TUM INTO WOOD & STEEL: I , FALLATION STEPS - G3929 M INTO WOOD & STEEL Insert the appropriate nut driver into a 3/8"or 1/2"portable drill Insert the SAMMYSID into the #14 (black) nut driver (p/n 8113910). Drill should be in a vertical position. Push the face of the nut driver tight to the member. Begin installation when the nut driver spins freely on the SAMMYS, slop drill and remove. The SAMMYS is now ready to receive 1/4", 3/8", 1/2' or metric all thread rod, bolt stock. (The 1/2" requires the #14SWred nut driver) Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximumpullout in purlin steel. Insert the appropriate nut driver into a 3/8"or 1/2" portable drill. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill unit in a horizontal position and at a right angle to the structural member, begin installation. When the nut driver spins freely on the SAMMYS, stop the drill and remove. The unit is now ready to receive 1/4', 3/8', Mb, M8 or metric all thread rod or bolt stock. Note: When installing SWDR, follow the above instructions, then add retainer nut and torque 1020 foot lbs. for maximum pullout in purlin steel. INSTALLATION STEPS -!4iiNL INTO CONCRETE: Using an SDS 250 carbide tip bit or a HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2' with a hammer/rotary hammer drill set on impact mode. After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #14 (black) nut driver (p/n 8113910) into the opposite end (see Vertical Installation note above). Insert the CST screw into the nut driver. Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins freely on the CST screw, installation is complete. Stop and remove drill. The concrete screw is ready to receive 1/4", 3/8'. 1/2', or metric all thread rod or bolt stock. (#I4SW red nut driver used with 1/2' screw) Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the screw. INSTALLATION STEPS - WiiI9IJ1i1L INTO CONCRETE:] I. Using an SDS 250 carbide tip bit ore HEX RECEIVER with a #250 carbide tip bit, pre-drill the concrete member to a depth of 2" with a hammerl rotary hammer drill salon impact mode After pre-drilling has been completed, install the SLEEVE TOOL over the bit (the bit should remain in the drill), and insert the #I4SW(red) nut driver (p/n 8114910) into the opposite end. Insert the SWC screw into the nut driver Place tip of screw into the pre-drilled hole, turn impact/drill unit to drill mode and begin insertion. When the nut driver spins free on the SWC screw, installation is complete. Stop and remove drill. The SWC screw is ready to receive 1/4", 318"or metric all thread rod or bolt stock. Note: Use a 1200 maximum RPM drill for installation. Note: Do not install concrete screws while the drill unit is in impact mode - doing so will destroy the pullout factor of the fastener 0"08mi - - tI1M 111111111IMPIR SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driverfor installations. SAMMYS FOR STEEL Made with Teks® Self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 1/2 thicknesses. Saves time from traditional methods. "Reduces installation costs. "Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. p Made in the U.S.A. f-71 Walcha vkjeodemonsfrauon 01 www.itwbulldex.com 1/4' 8024957 DSTR100 1/4-20x1'TEKS3 1510 (20ga.) .036'-20ga 3/16' 25 125 In 1/4 8025957 DST 100 114-14 x I TEKS3 446 (20ga) .03r-2O ga 3/116 25 U6- 1/4" 8026957 DST 150 1/4-14x1-112" TEKS 3 970 (16ga.) .036"-20ga 3/16' 25 125 1/48027957 DST 200 - 1/414x2TEKS3 446 (20ga) - - - 036 20ga 3/16 25 125 114" 8030957 TEK500 I2-24x1-112" TEKS 5 3125 (3/16") .188"-3/16" 1/2' 25 125 3/8 —80507760R1 1/4201 TEKS3 1510 (20ga) 1500 1475 .03F-20 ga 3/16 25 125 ' 318" 8037957 DSTR 1-1/2 • 12-24 x 1-112' TEKS 5 1510 (3/16) 1500 1475 .060'-16 ga. 1/2" 25 125 #14 Black I '' 3/8" 8039957 DSTRS16" 5/16-I8x1-1/4TEKS3 2200(20ga.) 1500 1475 .036"-20ga 3/16" 25 125 11 Nut Driver Pa#8113910 Part 3/8' 8040957 DST 10 I/4-14x1' TEKS 3 446 (20 ga.) .036"-20ga 3/16' 25 125 - 3/8' 8077925 DST 10-SS 1/4-14x1'TEKS3 446 (20 - - - .036"-20ga 3/16' 25 125 3/8" 8041957 DST 15 1/4-I4x1-1/2"TEKS3 446 (20 .036"-20ga 3/16" 25 125 3/8" 8078925 DST 15-SS 1/4-14x1-1/2'TEKS3 446 (20 .036'-20ga 3/16' 25 125 3/8" 8042957 DST 20 1/4-14x2'TEKS3 446 (20ga.) .036"-20ga 3/16" 25 125 970 (16ga.) [ 3/8" 8043957 0S125 1/4-14x2-1/2"TEKS3 446 (20 .036'-209a 3/16" 25 125 3/8" 8044957 DST 30 1/4-14x3" TEKS 3 446 (20 .036"-20ga 3/16" 25 125 3/8 - 8045957 DST 516 5/16-18x-1-11 /4TEKS3 1500(3/16) 1500 - 1475 1251/8 - 3/16 25 125 3/8" 8046957 TEKSO 12-24x1-1/2" TEKS 5 3125 (3/16") 1500 1475 .250"-1/4' 1/2' 25 125 [ 1/2" 8031925 DST 1/4-14x2"TEKS3 446 (20 .188"-3/16' 1/4" 25 125 1/2' 8033925 DSTRI.O' 1/4-20x1'TEKS3 1510 (20ga.) .036'-20ga 3/16' 25 125 I [ . 1/2 8034925 DSTR5I6 5/I618x1114 TEKS 3 2220 (20ga) - - 036 20ga 3/16 25 125] I 1/2" 8035925 DST 5.16 5/16-18 x 1-1/4' TEKS 3 1500 (3/16") .125'-1/8" 3/16" 25 125 #14SWRed L L - 1/2' 8036925 TEK5.0 12-24x1-1/2 "TEKS 5 - 3125 (3/16') - 188"-3/16" - 1/2" 25 125 Nut Driver Part #8114910 indudes retaining nut oILS SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and sate installation each time. When the lace of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins is ____ free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. Made with Teks® self-drilling fasteners - no pre-drilling required. Installs into steel range from 20 gauge - 112" thicknesses. 0 Ing • A standard screwgun with a depth sensitive nosepiece should be used to install Teks. For optimal fastener performance, the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. Saves time from traditional methods. Reduces installation costs. Quick to install using the Sammys Nut Driver with an 18V cordless drill/driver. Made in the U.S.A. www.Itwbulldex.comJ 114" 8047957 SWD 100 1/4-14 x 1"TEKS 3 1477 (16 ga.) .060-16 ga 3/16" 25 125 1/4 8049957 SWDR 100 11420x1 TEKS3 1900 (20 ga.).036"-20ga 3/16 25 125 3/8" —SW D-- 10 8050957 1/4-14 Xl" TEKS 3 1477 (16 ga.) .060"-16 ga 3/16" 25 125 r 3)8 8080925 SWD10-SS 1/414x1 TEKS3 1477 (1604) - 060 l6ga 3/16 25 '125- 318" 8051957 SWD15 1/4-14 x 1 1/2 TEKS3 1477 (16 ga.) .060"-16 ga 3/16 25 125 - 3/8 8052957 SWD2O l/414x2TEKS3 1477'(16 ga.) .060"-16 ga 3/16 25 12,57 3/8" 8053957 SAID 516 5/16-18 x 171/4" TEKS 3 2480 (20 ga.) .036"-20 ga 3/16" 25 125 qL 3/8 8055957 SWDRI 1/420x1 TEKS3 1900 Q0 ga.) 1500 _j475 .036"-20 ga _3/16 25 125 #14 SW Red 3/8" 8054957 SWDR 1-1/2 * 12-24 x 1-1/2" TEKS 5 2375 (3/16") 1500 1475 .188"-3/16" 1/2" 25 125 Nut Driver [ 3/8 8056957SWDR /16 /4TEKS3 2480 (20 ga) 1500 1475 03620 ga 3/16 25 i25 1 Part #8114910 3/8" 8057957 SWT15 12-24x1-112"TEKS5 2375(3/16") .188"-3/16" 1/2" 25 125 "Includes retaining nut '1 #14 Black Nut Driver - Part # 8113910 #14 SH Orange Nut Driver Part #8273910 €" 3/8" 8137957 SHDSTRI" 1/420Xi TEKS 3 3/8" 8268957 SH-TEK 50 12-24 x 1-3/4" TEKS 5 1/2" 8270957 SH-TEK5.0 12-24 a 1-3/4" TEKS 5 "Does not comply with R011S requirements Includes retaining aid 1306(45" off Vertical) 1500 (Vertical) 4" 2281 (3/16" HSS) 850(45" off Vertical) 2-1/2" 1585(3/16" HSS 45" off Vertical) 2368(1/2" steel Vertical) 1306(45" off Vertical) 2281 (3)16" HSS) 1585 (3/16" HSS 45" off Vertical) "Eliminates distortion of threaded rod in sloped roof applications. Accommodates 3-1/2 x 12 pitch. "Installs into angled z-purtin; allows threaded rod to hang plumb. "Allows 17° deflection from vertical. "Made in the U.S.A. rid a video demonsvation vi wwwdtwbuildex.com 3220(3)16") 1500 1475 .035" 3)16" 25 125 2368(1/2" steel Vertical) 3/16" 1/2" 25 125 3/16" 1/2 25 125 S A 1141111 V X-PRESS@ Installs into Metal Deck, Purlin, or Tubular Steel The Sammy X-Press expands to provide direct vertical attachment in: light gauge steel deck or purlin (22 ga. - 1/8"). Installs in seconds with Sammy X-Press lt8 Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor barrier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. Mich a wcw damonstraOon at www.itwbulldex.com 114" 8181922 XP 200 Sammy1146(22ga) 185 (Luminaire) .027' .125" 25 125 Metal Deck X-Press 200 250 (Luminaire) .056" F 850 (2W Pipe) 940 (2' Pipe)Samm 029" .027' I 'Sa 3/8" 8150922 XP 20 X-Press 20 1146 (22 ga) 185 (Luminaire) 250 (Luminaire) 1475 (4027'" Pipe) .104" .125" 25 125 Metal Deck 283 (Conduit & Cable) .029' 1500 (4' Pipe) .060" .. S 3/8" 8153922 XP 35 Sammy 1783 (16 gal 125" 25 125 Pudin X-Press 250 (nhinaj) 056: 1475 (4• Pipe) 416 (Conduit & Cable) .059" Pre tructuralrete©0O0psi 3/& 8150922 XP 20 Sammy1146 (22 ) 850 (24 Pipe) 25 125 X-Press 20L - Post-Pour Range II LWCtg 35 PCF (lbs/b) Metal Dad (Post-Pour) Pre-Pour Structural Concrete @3000 pal Post-Pour Range It LWCS 35 PCF libel ft) fJLJrJ4 Less jobsite material needed. The SidewinderX-Press expands to provide horizontal attachment in: - 16 go -3/16" steel - purlin, tubular steel. • No retaining nut required. Installs in seconds with Sammy X-Press It"Tool, "Provides design flexibility. • saving time & installation costs. "Made in the U.S.A. Use in applications where access to the back of the installed fastener is prohibited; ie. metal roof Watch a 4doo dffunstrattc\ deck, tubular steel, or vapor barrier fabric. fmm wwwJiwbui!dexcomJ 4. 30 8293957 SWXP35 SidevAnder 1798 (16 ga) 80(Luminaire) 059" 125" 25 125 Put/in L _______ - i/17AYiSi The SwiveIX-Press allows you to hang plumb in extreme roof pitches: - 89° in z-purlin - 450 in metal deck for 12/12 pitch Installs in seconds with Sammy X-Press 11n Tool, saving time & installation costs. Use in applications where access to the back of the installed fastener is prohibited. ie. metal roof deck, tubular steel, or vapor banier fabric. Less jobsite material needed. No retaining nut required. Provides design flexibility. Made in the U.S.A. @ Watch a video demonstration at w.'w.ItwbuiIdex.com 170 Vertical (Luminaire) 4 3/8' 8294922 SXP 20 SvAvel 1061 (22 X-Press 20 rt) 80 @450 (Luminaire) .029' 635 (2' Pipe) .029' .125' 25 125 Metal Deck Off Vert) 283 Vertical (Conduit & Cable) - 233@45° (Conduit &Cable) 1258 (3-1/2' Pipe) Svrivel 1675 (16 ga Vert) 250 Vertical (Luminaire) 3/8' 8295922 SXP 35 X-Press 1558 Off Vert) 0Vcal (Conduit& Cable) 635 (2' Pipe) .029' .125' 25 125 Pudin 333 @890 (Conduit & Cable) SvA SXP vel 1061 (22 Vert) 25 125 Metal Deck Swivel 1675 (16 ga Vert) 1/2 8271957 SXP 3.5 X-Press3.5 1558(89° Off Vert) .060' .125' 25 125 Pudin :I*I I T' Installation T ool J7llT1i.,s Product Features The Sammy X.Press expands to provide direct vertical attachment in: \ metal deck (2216 z-purlin (18-16 gauge) .7L. t Number Model 'ltUr.ii oty 8194910 UXPIT° Universal X-Press It Tool 8152910 XPDB 25/64 Drill Bit 1 'Tool Includes: Sleeve, Bit Receiver, Hex wrench, and 28/64' 0611 Bit. rAPPROVALS - 8007957 GST 10 3/8" Vertical CPVC 1-112" 300 1-112" 8020957 SWG 10 3/8" Horizontal CPVC 1-1/2" 300 1-1/2' 8008957 3ST20 3/8" Vertical 2-1/2" 850 1-1/2" 4" 1475 1-1/2" 8068925 3ST 20-SS 3/8" Vertical 2-1/2' 850 1-1/2" 8010957 GST 30 3/8" Vertical 4" 1500 1-1)2" 4" 1475 1-1/2' 8009925 3ST25-380 .3/8" Vertical 4" 1500 1-1/2" 8022925 SWG 25-380 .3/8" Horizontal 3-1/2" - 4"" 1500 1-1/2" 8021957 SWG 20 .3/8" Horizontal 2-1/2" - 3'"" 1050 1-1/2" 8073925 SWG 20-SS 3/8" Horizontal 2-1/2" 850 1-1/2" 8269957 SI-l-GST/CST 20 3/8" 45" Angle off Vertical 2-1/2" 850 1-1/2" 8269957 SH-GST/CST 20 3/8" 45" Angle off Vertical 4" 1500 1-1/2" 8139957 SH-GST2O 3/8" 17" Angle off Vertical 1050 1-1/2" 4" 1475 1-1/2" I 8038957 DSTR 1 3/8" Vertical 4' 1500 .035' 4" 1475 .105" 8037957 DSTR 1-112 3/8" Vertical 1500 .035" 4" 1475 .105" 8039957 DSTR 516 3/8" Vertical 4" 1500 .037" 4" 1475 .105" 8045957 DST 516 3/8" Vertical 4" 1500 .188" 4" 1475 .188" 8046957 TEK5O 3/8" Vertical 4" 1500 .250" 4' 1475 .188" 8055957 SWDR 1 3/8' Horizontal 4" 1500 .037" 4" 1475 .060" 8056957 SWDR 516 318" Horizontal 4" 1500 .037" 4" 1475 .060" 8054957 SWDR 1-1/2 3/8" Horizontal 4" 1500 .037" 4" 1475 .060" 8137957 SH-DSTR1 3/8" 17" Angle off Vertical 4" 1500 .035" 4" 1475 .105" 8268°57 SH-TEK5O 3/8" Vertical 2-1/2" 850 70" Angle off Vertical 4" 1500 8150822 XP 20 3/8" Vertical 2-1/2" 850 .027" , 1475 .105" 8153922 XP 35 3/8" Vertical 4" 1500 .060" 4. 1475 125" 8294922 SXP 20 3/8" Vertical orupto45" 2" 750 .027" 2" 635 .029" 8295922 SXP 35 318" Vertical orupto89" 3-1/2" 1250 .060" 2" 635 .029" 8293957 SWXP35 3/8" Horizontal 3-1/2" 1250 .060' I SAMMI'S FOR CONCRETE -PIPE HANGER 8059957 CST 20 3/8" Vertical 4" 1475 3000 8061957 SWC2O 3/8" Horizontal 4" 1475 3000 8150922 XP 20 3/8" Vertical 2-1/2" 850 Pre-Pour Structural @ 3000psi 8150922 XP 20 3)8" Vertical 2-1/2" 850 Post-Pour Range II LWC 35 PCF (lbs/ftt) 8150922 XP 20 3/8" Vertical 185 .027" 250 .035" 185 .027" 8153922 XP 35 3/8" Vertical 250 035' 185 .027" 818922 XP 200 1/4" Vertical 250 .035" Vertical 170 .027" 8294922 SXP 20 3/8" 45° 80 .027" Vertical 250 .060" 8295922 SXP 35 3/8" 900 80 .060" 8293957 SWXP 35 3/8" Horizontal 80 .060" 8150922 XP 20 3/8" Vertical 283 .027" Max trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 815,922 XP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 8294922 SXP 20 3/8" Vertical 283 .027" Max 4 trade size EMT, RMC, and IMC & 5 trade size rigid PVC conduit 8295922 SXP 35 3/8" Vertical 500 .060" Max 4 trade size EMT & 6 trade sze RMC, IMC, and rigid PVC conduit 829/857 SWXP 35 3/8" Horizontal 500 .060 Max 4 trade size EMI & 6 trade sze RMC, IMC, and rigid PVC conduit 8149357 CZ2000 1/4 or 3/8 Onto Vertical Rod UL Listed 4S16 -Cable Hanger, Cat No. C12000 Plenum Rated, Complies W/ NEC Standards Gauge No. 22ga. 20ga. 18ga. 16ga. 14ga. 12ga. 1/8" 3/16" 1/4" Nominal Decimal Equivalent .030" .036" .048" .060" .075" .105" .125" .188" .250" SWG 25-380 Maximum pipe size in composite wood joist allowed by UL is 3-1/2' UL compliance with NEC Standards. *SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is UL and FM tests were performed in compliance with NEPA 13 Standards. "SW'3 20 Maximum pipe size in composite wood joist allowed by ML is 2-1/2' Fastening requirement: 5 times weight of water-filed schedule 40 pipe plus 250 pounds. '.SWG 20 Maxirrum sixe size in wood timber or isist allowed by UL is 3" SPECIAL NOTES Engineering Note In 1996, the anchors listed by UL were tested in plate steel that measured .188' and .118". Subsequent testing was done for z-pwlin applicaions in May 1997 using (.037") or 20 gauge steel. Most recently in 2008, testing with the new Sammy X-Press® was completed using (.030") or 22 gauge steel metal deck. Sammys€ Nut Drivers Special nut drivers were designed to be used with Sammys. When the appropriate nut drivers are used for installaben, the driver spins freely on the screw after installation is complete and eliminates the expected wrist snap, reduces over-torque, and prevents screw failure. Steel Screws Due to variations in hardness of certain metals, it should be noted that our self-drilling screws for steel will experience different drill speeds. 500-1500 RPM drill speed should be used. Metric Products Metric versions of the Sammy anchors are available at www.itwbuildex.com Sammys for Seismic Please visit www.itwbuildex.com for our current Seismic product offerring. Vibratory EnvironmentsV For attaching or anchoring in high vibratory environments, special care should be taken not just for building attachments but also for the hangers or assemblies being supported. Consult local code authorities for accepted anchoring devices. Composite Joist/Truss Truss manufacturers vary installation recommendations for composite joist. UL testing was completed to validate that Sammys and Sidewinders SWG 20 and SWG 25-380 can be installed into the top cord of a truss. Sammy GST 20 can be installed into the center of the lower cord of a composite joist Penetration of the upright center web is permitted by some joist manufacturers. Consult truss manufacturer for recommended installation point. Pre-drilling may be required by joist manufacturers. If so, pre-drill pilot hole 1/8" smaller than root diameter of fastener. Consult the table below: Model Root Diameter Hole Size GST 20 .182" 1 1/8" GST 25-380 .280" 7/32' SWG 20 .182" 1/8" SWG 25-380 .280" 7/32" To increase efficiency of the installation process, sleeve tools, bit receivers, and wood bits are available for pre-drilling. NFPAINEC Standards All UL and FM testing complies with NFPA 13 and NEC standards. Check with your local (AHJ) Authority Having Jurisdiction to confirm application and usage. UL Listings I FM Approvals UL and FM reports are available at www.itwbuildex.com u no PWEIWIGER .LsOcflmoAScu,nCAnEkum *.L1OL1DASM1OILWSAfl 21 Technical Drawings Technical drawings are available and can be downloaded at www.itwbuildex.com in the following formats: .dwg, .dxf, and .igs. Made In the U.S.A. Products MM Contact Information Technical Assistance: (800) BUILDEX Option #6 (x 3259) Customer Service: (800) BUILDEX Option #1 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 3.3.7.1 Product description Suitable for reduced edge distances and spacing. 3.3.7.2 Material specifications KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8 pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product features Suitable for cracked and uncracked normal-weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size. KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8 pm. 3.3.7.3 Technical data 3.3.7.3.1 ACI 318-14 Chapter 17 design The technical data contained in this section are Hilti Simplified Design Tables. The load values were developed using the design parameters and variables of ESR-3027 and the equations of ACI 318-14 Chapter 17. For a detailed explanation of the Hilti Simplified Design Tables, refer to section 3.1.8. Data tables from ESR- 3027 are not contained in this section, but can be found at www.icc-es.org or at www.us.hilti.com. 3.3.7.1 Product description 3.3.7.2 Material specifications 3.3.7.3 Technical data 3.3.7.4 Installation instructions 3.3.7.5 Design guidelines 3.3.7.6 Ordering information Listinas/ADDrovals ICC-ES (International Code Council) ESR-3027 City of Los Angeles Research Report No. 25897 FM (Factory Mutual) Pipe Hanger Components for Automatic Sprinkler Systems for 3/8 internal threaded diameter anchor LADBS -<FM> Independent code evaluation lBC®/ IRC®2015 IBC/ lRC®2012 lBC®/ IRC®2009 IBC®/ IRC® 2006 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Huh (Canada) corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 319 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 1 - Hilti KWIK HUS-EZ I specifications1'2 Setting information Symbol Units Nominal anchor diameter 1/4 Nominal bit diameter dbt in. 1/4 Nominal embedment ~om in. 1-5/8 2-1/2 Effective embedment h f in. 1.18 1.92 Minimum hole depth h0 in. 2 2-7/8 Installation torque T. nst (Nm) ft-lb 18 (24) Wrench size in. 7/16 1 T, is the maximum installation torque that may be applied with a torque wrench. 2 See table 2 and figure 5 of section 3.3.6 for spacing, edge distance, and concrete thickness pa- rameters Figure 1 - KWIK HUS-EZ I anchor installation details wrench size da () - J•. : lanch - - hef h0,-,, 1 a - - - -, Table 2 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in uncracked concrete1'2'3'4'5 Nominal Nominal Tension - cpN,, Shear - qV anchor embed. f' 2,500 psi I,, = 3,000 psi f = 4,000 psi f',=6,000 psi f',, = 2,500 psi f' = 3,000 psi 1',, 4,000 psi f 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 585 620 675 765 1,075 1,180 1,360 1,670 1 / (41) (2.6) (2.8) (3.0) (3.4) (4.8) (5.2) (6.0) (7.4) 2-1/2 1,525 1,670 1,930 2,365 2,235 2,450 2,825 3,460 (64) (6.8) (7.4) (8.6) (10.5) (9.9) (10.9) (12.6) (15.4) Table 3 - Hilti KWIK HUS-EZ I design strength with concrete / pullout failure in cracked concrete' 2'3'4'5 Nominal Nominal Tension - cN Shear - On anchor embed. 1' = 2,500 psi f' = 3,000 psi f', = 4,000 psi f' = 6,000 psi f = 2,500 psi f', = 3,000 psi f' = 4,000 psi 1,, = 6,000 psi diameter depth (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) (17.2 MPa) (20.7 MPa) (27.6 MPa) (41.4 MPa) in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 300 315 345 390 765 835 965 1,180 1 (41) (1.3) (1.4) (1.5) (1.7) (3.4) (3.7) (4.3) (5.2) / 2-1/2 760 830 960 1,175 1,585 1,735 2,000 2,450 (64) (3.4) (3.7) (4.3) (5.2) (7.1) (7.7) (8.9) (10.9) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 and 6 as necessary. Compare to the steel values in table 4. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by X as follows: for sand-lightweight, A0 = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic tension loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - a5 = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - aN = 0.75 No reduction needed for seismic shear. See Section 3.1.8.7 for additional information on seismic applications. Table 4 - Steel design strength for Hilti KWlK HUS-EZ I anchors1'2 Nominal anchor Nominal internal Tensile3 Shear4 Seismic shear' diameter thread diameter qV V. in. in. lb (kN) lb (kN) lb (kN) 1/4-20 3,680 815 365 1 / UNC (16.4) (3.6) (1.6) 3/8-16 3,680 790 670 UNC (16.4) (3.5) (3.0) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I anchors are to be considered brittle steel elements. 3 Tension = OA. Nfu, as noted in ACI 318-14 Chapter 17. 4 Shear determined by static tests with (DV_ <O.64A,00 f,, as noted mACI 318-14 Chapter 17. 5 Seismic shear values determined by seismic shear tests with !~ 4 0.60 A se.V futa as noted in ACI 318-14 Chapter 17. See Section 3.1.8.7 for additional information on seismic applications. 320 Hilti, Inc. (us) 1-800.879-8000 1 www.us.hilti.com I en español 1-800-879.5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 5 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in uncracked concrete12 Edge distance in shear 11to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .L toward edge from edge factor in shear4 uncracked concrete IAN fRN 'AV 'RV fRy IHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 hnom (mm) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2 (38) 0.71 0.63 0.78 0.65 0.59 0.56 0.40 0.21 0.78 0.42 n/a n/a 2 (51) 0.78 0.67 leo 0.77 0.62 0.58 0.61 0.33 1.00 0.65 n/a n/a j 2-1/2 (64) 0.85 0.72 0.90 0.65 0.60 0.86 0.46 0.90 n/a n/a 3 (76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4 (83) 0.96 0.78 0.70 0.63 _______ 0.68 0.88 n/a - -- 3-1/2 (89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a E 4 (102) 1.00 0.85 0.74 0.66 0.92 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 CO 4-1/2 (114) 0.89 0.77 0.68 1.00 0.84 5 (127) 0.93 0.80 0.70 1 0.89 5-1/2 (140) 0.98 0.83 0.72 0.93 - (152) 1.00 0.86 0.74 0.97 7 (178) 0.92 0.78 1.00 8(203) 0.98 0.82 9 (229) 1.00 0.86 CO 10(254) 0.89 11(279) 0.93 12(305) 0.97 14(356) 1.00 Table 6 - Load adjustment factors for 1/4-in, diameter Hilti KWIK HUS-EZ I in cracked concrete' 2 Edgedistanceinshear II to and away Spacing factor Edge distance Spacing factor Conc. thickness 1/4-in. KH-EZ in tension factor in tension in shear3 .L toward edge from edge factor in shear4 cracked concrete JAN 1RN 1AV fRy 11V IHV Embedment in. 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 1-5/8 2-1/2 h nom (mm) (41) (64) 1 (41) (64) (41) (64) (41) (64) (41) (64) (41) (64) 1-1/2(38) 0.71 0.63 0.88 0.65 0.59 0.56 0.40 0.21 0.80 0.43 n/a n/a 2(51) 0.78 0.67 1.00 0.77 0.62 0.58 1 0.62 0.33 1.00 0.66 n/a n/a 2.1/2(64) 0.85 0.72 0.90 0.65 0.60 0.87 0.46 0.90 n/a n/a 3(76) 0.92 0.76 1.00 0.68 0.62 1.00 0.60 1.00 n/a n/a 3-1/4(83) 0.96 0.78 0.70 0.63 0.68 0.89 n/a 3-1/2(89) 0.99 0.80 0.71 0.64 0.76 0.92 n/a 4(102) 1.00 0.85 0.74 0.66 0.93 0.98 n/a 4-1/8 (105) 0.86 0.75 0.66 0.97 1.00 0.81 CO 4-1/2(114) 0.89 0.77 0.68 1.00 0.85 5(127) 0.93 0.80 0.70 0.89 0) )t ci) 5-1/2(140) 0.98 0.83 0.72 0.93 6(152) 1.00 0.86 0.74 0.98 7(178) 0.92 0.78 1.00 8(203) 0.98 0.82 9(229) 1.00 0.86 10(254) 0.90 11(279) _____ 0.94 12 (305) 0.98 14(356) 1.00 1 Linear interpolation not permitted. 2 When combining multiple load adjustment factors (e.g. for a 4 anchor pattern in a corner with thin concrete member) the design can become very conservative. To optimize the design, use Hilti PROFIS Anchor Design software or perform anchor calculation using design equations from ACl 318-14 Chapter 17. 3 Spacing factor reduction in shear, fAA' assumes an influence of a nearby edge. If no edge exists, then 'AV 4 Concrete thickness reduction factor in shear, f Hv assumes an influence of a nearby edge. If no edge exists, then fv = 1.0. If a reduction factor value is in a shaded cell, this indicates that this specific edge distance may not be permitted with a certain spacing (or vice versa). Check with table 5 and figure 2 of section 3.3.6 to calculate permissable edge distance, spacing and concrete thickness combinations. 1-lilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hiltLca I Anchor Fastening Technical Guide 2016 321 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 7 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 2,3,4,5,6,7 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - pN Shear - Tension - N, Shear - 4V anchor thread embed. f= 3,000 psi f'= 4,000 psi f'= 3,000 psi f'= 4,000 Ps f= 3,000 psif = 4,000 psi f= 3,000 psi f',= 4,000 Ps diameter diameter depth (20,7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 545 595 610 610 670 730 610 610 1/4-20 (41) (2.4) (2.6) (2.7) (2.7) (3.0) (3.2) (2.7) (2.7) UNC 2-1/2 1,220 1,410 610 610 1,275 1,470 610 610 (64) (5.4) (6.3) (2.7) (2.7) (5.7) (6.5) (2.7) (2.7) 1 / ______ 1-5/8 545 595 915 915 670 730 915 915 3/8-16 (41) (2.4) (2.6) (4.1) (4.1) (3.0) (3.2) (4.1) (4.1) UNC 2-1/2 1,220 1,410 915 915 1,275 1,470 915 915 (64) (5.4) (6.3) (4.1) (4.1) (5.7) (6.5) (4.1) (4.1) Table 8 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - qN Shear - 4V,, Tension - 4N,, Shear - On anchor thread embed. f',= 3,000 psi f'= 4,000 psi f= 3,000 psi f'= 4,000 psi f'= 3,000 psi f= 4,000 psi f',= 3,000 Psi 4,000 psi diameter diameter depth (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) (20.7 MPa) (27.6 MPa) in. in. in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1-5/8 280 305 610 610 330 360 610 610 1/4-20 (41) (1.2) (1.4) (2.7) (2.7) (1.5) (1.6) (2.7) (2.7) UNC 2-1/2 605 700 610 610 635 735 610 610 ______ (64) (2.7) (3.1) (2.7) (2.7) (2.8) (3.3) (2.7) (2.7) 1/4 1-5/8 280 325 915 915 330 380 915 915 3/8-16 (41) (1.2) (1.4) (4.1) (4.1) (1.5) (1.7) (4.1) (4.1) UNC 2-1/2 605 700 915 915 635 735 915 915 (64) (2.7) (3.1) (4.1) (4.1) (2.8) (3.3) (4.1) (4.1) 1 See Section 3.1.9.4 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x h0 ,,, (nominal embedment). 4 Tabular values are lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular Values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by = 0.75. 8 For seismic shear, an additional factor must be applied to the cracked concrete tabular values for seismic conditions: 1/4-in diameter by 1-5/8-in nominal embedment depth - 0.44 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.85 See Section 3.1.8.6 for additional information on seismic applications. 322 Hilti, inc. (US) 1-800-879-8000 1 www.us.hiiti.com i en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hitti.ca i Anchor Fastening Technical Guide 2016 Mm. 4-1/2 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Figure 2— Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in soffit of concrete over steel deck floor and roof assemblies Mm. 3/4' Mm. 3,000 psi sand-lightweight Upper or normal-weight concrete flute .L1 (typical) -Anchor Flute edge (typical) Mm. 1-1/4 - Mm. 12" (typical) ) - )) -- .i ..i- -. Minimum 20 gauge steel deck \_ Lower flute - (ridge) 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. PO 1 3.3.7.3.2 Canadian Limit State design Limit State Design of anchors is described in the provisions of CSA A23.3-14 Annex D for post-installed anchors tested and assessed in accordance with ACI 355.2 for mechanical anchors and ACI 355.4 for adhesive anchors. This section contains the Limit State Design tables with unfactored characteristic loads that are based on the published loads in ICC Evaluation Services ESR-3027. These tables are followed by factored resistance tables. The factored resitance tables have characteristic design loads that are prefactored by the applicable reduction factors for a single anchor with no anchor-to-anchor spacing or edge distance adjustments for the convenience of the user of this document. All the figures in the previous ACI 318-14 Chapter 17 design section are applicable to Limit State Design and the tables will reference these figures. For a detailed explanation of the tables developed in accordance with CSA A23.3-14 Annex D, refer to Section 3.1.8. Technical assistance is available by contacting Hilti Canada at (800) 363-4458 or at www.hilti.ca Table 9 - Steel resistance for Hilti KWIK HUS-EZ I carbon steel screw anchor12 Nominal Internal anchor thread Tensile' Shear4 Shear' diameter diameter Nsar V in. (UNC) lb(kN) lb(kN) lb(kN) 3,370 750 335 1/4 1/4-20 (150) (3.3) (1.5) 3,370 725 620 1/4 3/8-16 (15.0) (3.2) (2.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Hilti KWIK HUS-EZ I carbon steel screw anchors are to be considered brittle steel elements. 3 Tensile N = A5 (% f1 R as noted in CSA A23.3-14 Annex D. 4 Shear determined by static shear tests with V r < A 5 4 0.6 f R as noted in OSA A23.3.14 Annex D. 5 Seismic shear values determined by seismic shear tests with <A05 p 0.6 f R as noted in CSA A23.3-14 Annex D. See section 3.1.8.7 for additional information on seismic applications. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 323 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 10 - Hilti KWIK HUS-EZ I design information in accordance with CSA A23.3-14 Annex D1 N Design parameter Symbol Units Nominal anchor diameter Ref 1/4 A23.3-14 Anchor O.D. da in. 1/4 (mm) (6.4) Effective embedment' h6f in. 1.18 1.92 (mm) (30) (49) Minimum nominal embedment2 2-1/2 h in. 1-5/8 nonn (mm) (41) (64) Minimum concrete thickness h in. 3-1/4 4-1/8 min (mm) (83) (105) Critical edge distance C,in. 2.00 2.78 (mm) (51) (71) Minimum spacing at critical edge distance 5,cin,cac in. 1.5 (mm) (38) Minimum edge distance c in. 1.50 min (mm) (38) Minimum anchor spacing at minimum edge distance for s> in. 3.0 (mm) (76) Mininimum hole depth in concrete h0 in. 2 2-7/8 I (mm) (51) (73) Minimum specified ultimate strength f.. psi 125,000 (N/mm2) (862) in 0.045 Effective tensile stress area AseN (mm2) (29.0) Steel embed. material resistance factor for reinforcement t - 0.85 8.4.3 Resistance modification factor for tension, steel failure modes3 R - 0.70 D.5.3 Resistance modification factor for shear, steel failure modes3 R - 0.65 D.5.3 lb 3,370 Factored steel resistance in tension D.6.1.2 (kN) (15.0) lb 750 Factored steel resistance in shear V 0.7.1.2 1/4-20 UNC internal thread (kN) (3.3) lb 335 Factored steel resistance in shear, seismic V eq (kN) (1.5) lb Factored steel resistance in shear 725 0.7.1.2 3/8-16 UNC internal thread (kN) (3.2) lb 620 -I Factored steel resistance in shear, seismic V req (kN) (kN) (2.8) Coeff. for factored conc. breakout resistance, uncracked concrete kcu,cr - 10 D.6.2.2 Coeff. for factored conc. breakout resistance, cracked concrete - 7 D.6.2.2 Modification factor for anchor resistance, tension, uncracked conc.4 qJ - 1.0 D.6.2.6 Anchor category - - 1 D.5.3 (c) Concrete material resistance factor - 0.65 8.4.2 Resistance modification factor for tension and shear, concrete failure modes, R - 0.75 1.00 0.5.3 (c) Condition B5 lb 665 1,645 Factored pullout resistance in 20 MPa uncracked concrete' Npruncr D.6.3.2 (kN) (3.0) (7.3) Factored pullout resistance in 20 MPa cracked concrete Nprcr lb 340 815 0.6.3.2 (kN) (1.5) (3.6) lb 275 815 Factored seismic pullout resistance in 20 MPa cracked concrete Npreq D.6.3.2 (kN) (1.2) (3.6) Design information in this table is taken from ICC-ES ESR-3027, dated December, 2015, tables 2, 3, and 4, and converted for use with CSA A23.3-14 Annex D. See figure 1 of this section. The KWIK HUS-EZ I is considered a brittle steel element as defined by CSA A23.3-14 Annex 0 section D.2. For all design cases, LPC.N = 1.0. The appropriate coefficient for breakout resistance for cracked concrete (k,) or uncracked concrete must be used. For use with the load combinations of CSA A23.3-14 chapter 8. Condition B applies where supplementary reinforcement in conformance with CSA A23.3-14 section D.5.3 is not provided, or where pullout or pryout strength governs. For cases where the presence of supplementary reinforcement can be verified, the resistance modification factors associated with Condition A may be used. For all design cases, qi 1. = 1.0. NA (not applicable) denotes that this value does not control for design. See section 4.1.4 of ESR-3027 for additional information. 324 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hitti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 11 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in uncracked concrete' 2,3,4,5 Nominal ___________ Tension - N Shear - V I = 20 MPa I = 25 MPa / = 30 MPa f' = 40 MPa / = 20 MPa / = 25 MPa / = 30 MPa f = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) 1.18 1-5/8 665 710 750 820 805 900 985 1,135 (30) (41) (3.0) (3.2) (3.3) (3.6) (3.6) (4.0) (4.4) (5.1) 1 / 1.92 2-1/2 1,645 1,840 2,015 2,325 2,225 2,490 2,725 3,145 (49) (64) (7.3) (8.2) (9.0) (10.3) (9.9) (11.1) (12.1) (14.0) Table 12 - Hilti KWIK HUS-EZ I carbon steel screw anchor factored resistance with concrete/pullout failure H in cracked concrete' 2,3,4,5 Nominal ___________ Tension - N Shear - V f' = 20 MPa f = 25 MPa f = 30 MPa f' = 40 MPa / = 20 MPa f = 25 MPa f = 30 MPa f8 = 40 MPa anchor Effective Nominal diameter embed. embed. (2,900psi) (3,625 psi) (4,350 psi) (5,800 psi) (2,900 psi) (3,625 psi) (4,350 psi) (5,800 psi) in. in. (mm) in. (mm) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) lb (kN) - lb (kN) lb (kN) 1.18 1-5/8 340 360 385 415 565 630 690 795 (30) (41) (1.5) (1.6) (1.7) (1.9) (2.5) (2.8) (3.1) (3.5) 1 / 1.92 2-1/2 815 915 1,000 1,155 1,560 1,740 1,910 2,205 (49) (64) (3.6) (4.1) (4.4) (5.1) (6.9) (7.7) (8.5) (9.8) 1 See section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Apply spacing, edge distance, and concrete thickness factors in tables 5 to 6 as necessary. Compare to the steel values in table 9. The lesser of the values is to be used for the design. 4 Tabular values are for normal weight concrete only. For lightweight concrete multiply design strength by A8 as follows: for sand-lightweight, A. = 0.68; for all-lightweight, A. = 0.60 5 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by the following reduction factors: 1/4-in diameter by 1-5/8-in nominal embedment depth - = 0.60 1/4-in diameter by 2-1/2-in nominal embedment depth - = 0.75 See section 3.1.8.7 for additional information on seismic applications. Huh, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1.800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 325 3.3.7 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 13 - Hilti KWIK HUS-EZ I in the soffit of uncracked lightweight concrete over metal deck' 1,3,1,1,6.7 N Installation in lower flute Installation inupper flute Nominal Nominal internal Nominal Tension - Nr Shear -Vr Tension - N Shear -Vr anchor thread embed. f', = 20 MPa = 30 MPa f'c = 20 MPa f' = 30 MPa = 20 MPa = 30 MPa f, = 20 MPa f', = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 585 660 720 810 1/4-20 (41) (2.6) (2.9) 475 475 (3.2) (3.6) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) 1-5/8 585 660 720 810 3/8-16 (41) (2.6) (2.9) 565 565 (3.2) (3.6) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 1,200 1,470 1,255 1,535 (64) (5.3) (6.5) (5.6) (6.8) Table 14 - Hilti KWIK HUS-EZ I in the soffit of cracked lightweight concrete over metal deck' 2,3,4,5,6,7,8 N Installation in lower flute Installation inupper flute Nominal Nominal itern Nominal Tension - N, Shear - Vr Tension - Nr Shear -V, anchor thread embed. f = 20 MPa f' = 30 MPa f' = 20 MPa f' = 30 MPa f', = 20 MPa f, = 30 MPa f, = 20 MPa f' = 30 MPa diameter diameter depth (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) (2,900 psi) (4,350 psi) in. in. in. (mm) kN kN kN kN kN kN kN kN 1-5/8 300 340 365 415 1/4-20 (41) (1.3) (1.5) 475 475 (1.6) (1.8) 560 560 1/4 UNC (2.1) (2.1) (2.5) (2.5) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1-5/8 300 340 365 415 3/8-16 (41) (1.3) (1.5) 565 565 (1.6) (1.8) 845 845 1/4 UNC (2.5) (2.5) (3.8) (3.8) 2-1/2 595 730 625 765 (64) (2.6) (3.2) (2.8) (3.4) 1 See Section 3.1.8.6 to convert design strength value to ASD value. 2 Linear interpolation between embedment depths and concrete compressive strengths is not permitted. 3 Tabular value is for one anchor per flute. Minimum spacing along the length of the flute is 3 x (nominal embedment). 4 Tabular value is for lightweight concrete and no additional reduction factor is needed. 5 No additional reduction factors for spacing or edge distance need to be applied. 6 Comparison of the tabular values to the steel strength is not necessary. Tabular values control. 7 Tabular values are for static loads only. Seismic design is not permitted for uncracked concrete. For seismic loads, multiply cracked concrete tabular values in tension by %.,s = 0.75. 8 For the following anchor sizes, an additional factor for seismic shear must be applied to the cracked concrete tabular values for seismic conditions: For the 1/4x1 -5/8 anchor - = 0.45 For the 1/4x2-1/2 anchor - = 0.85 See Section 3.1.8.7 for additional information on seismic applications. 3.3.7.3.3 Allowable stress design for FM sprinkler systems Table 15 - Hilti KWlK HUS-EZ I (KH-EZ) tested load values for FM approval for automatic sprinkler systems' FM maximum Nominal embedment FM tension test load pipe diameter Hanger rod size in. lb in. 3/8-16 LING 1-5/8 1,475 2-1/2 4 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. 326 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.7 Table 16 - Hilti KWIK HUS-EZ I (KH-EZ I) allowable stress design values for installations into hollow core concrete panels1'2 Hanger rod size Min. effective embedment h in. Allowable load3 Ultimate load Tension lb Shear lb45 Tension lb Shear lb 1,5 1/4-20 UNC 1-3/8 455 485 1,810 1,930 3/8-16 UNC 755 3,025 1 The admissible anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm admissible anchor location. 2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. 3 Allowable loads calculated with a factor of safety of 4 4 The bottom of the shear plane adjacent to the top of the coupler. 5 Shear values controlled by the steel strength of the screws used to fasten the shear fixture to the KH EZ-1 Screw Anchor. The minimum tensile strength of the screw was 125 ksi. Shear design values should consider the screw or threaded rod steel strength. Figure 3 - Installation of Hilti KWIK HUS-EZ I (KH-EZ I) in hollow core concrete 3.3.7.4 Installation instructions Installation Instructions For Use (IFU) are included with each product package. They can also be viewed or downloaded online at www.us.hilti.com (US) and www.hilti.ca (Canada). Because of the possibility of changes, always verify that downloaded IFU are current when used. Proper installation is critical to achieve full performance. Training is available on request. Contact Hilti Technical Services for applications and conditions not addressed in the IFU. 3.3.7.5 Ordering information' Internal thread Internal thread Hole Minimum Description diameter length diameter embedment Qty/ box KH-EZ 1/4x1-5/811/4 1/4 3/8 1/4 1-5/8 100 KH-EZ 1/4x2-1/2 11/4 1/4 3/8 1/4 2-1/2 100 KH-EZ 1/4x1-5/8 13/8 3/8 7/16 1/4 1-5/8 100 KH-EZ 1/4x2-1/213/8 3/8 7/16 1/4 2-1/2 100 1 All dimensions in inches. Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2016 327 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1Ae 3/4 1 7/16 1 610 28 1/2 11/2 3/4 1 9/16 11/4 1130 55 5/8 1½ 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* Wt./100 3/8 1/ie 11/4 1 7/16 1 610 28 1/2 11/2 11/4 1 9/16 11/4 1130 55 5/8 1½ 11/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Component of State of California OSHPD Approved c L US Seismic Restraints System LISTED Size Range - (Fig. 65 and Fig. 66) 3/8', 1/2" and 5/8" rod Material - Carbon Steel with hardened cup point set screw and jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4" (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of the beam. (Beveled lip allows hanging from top flange where clearance is limited.) May be installed with the set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2" thru 4" pipe, 1/2" rod will support 1/2" thru 8" pipe. Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available in Electro-Galvanized and HDG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 II CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 25 - Surge Restrainer c®uS LISTED Size Range - One size fits 3/4" thru 2" pipe Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to restrict the upward movement of piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and efficiently installed by snapping into a locking position on the band hanger. This product is intended to satisfy the requirements as indicated in the National Fire Protection Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be used to restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed only when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (cUL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330 COOPER B-Line Component of State of California OSHPD Approved C@ us USTED Seismic Restraints System Dimensions • Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Size Range - Secures 3/8" thru 7/8" rod in 1" increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Fig. 98 - Rod Stiffener Size Range - Secures 3/8" thru 7/8" hanger rod Material - Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines Finish - Electro Galvanized Note - Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 - All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8' thru 7/8" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 D OFFICE/MANUFACTURING FACILITY - 1375 SAMPSON AVE. . CORONA, CA 92879 PH: 951.737.5599- FAX: 951.737.0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 200-2I2 to 200-8 Fig. 200 Fig. 200S Fig. 200 - "Trimline" Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) TOLCO Fig. 200F - "Trimline" Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) Fig. 200C - "Trimline" Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig. B317ONFC) Fig. 200S - "Trimline" Adjustable Band Hanger with Non-Captured Nut c@ us LISTED Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design - - - keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. For hanger with non-captured nut order Fig. 200S. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) - in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (FM) (3/4" (20mm) thru 8" (200mm)). Fig. 200-1 to 200-2 Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts - in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of - Fig. 200C Fig. 200F 200.1/2 1/2° (15) /8"-16 31/8" (79.4) 2I8" (66.7) 11 (5.0) 200-I4 3/4" (20) /8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) /8"-16 3J8" (85.7) 2/8" (66.7) 12 (5.5) 200-11I4 1/4" (32) I8"-16 33/4" (94.0) 2/8' (73.0) 13 (5.9) 200.11/2 11/2" (40) /8"-16 3I8" (98.4) 2/8" (73.0) 14 (6.4) 200-2 (50) /8"-16 41/2" (114.3) (76.3) 15 (6.9) 200.21/2 21/2" (65) /8"-16 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200-3 3" (75) /8"-16 5/8" (149.1) 4" (101.6) 29 (13.3) 200-3/2 31/2" (90) /8"-16 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) /8"-16 7/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"_13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-6 6" (150) 1/2"_13 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200-8 8" 1(200) /2"13 131/8" (333.4) 8I4" (222.2) 136 (62.3) All dimensions In charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 200M - "Trimline" Adjustable Band Hanger for Metric Rod ®VOLCO C®US Size Range: Fig. 200 - 1/2" (15mm) thru 8" (200mm) pipe LISTED Material: Steel, Pre-Galvanized to G90 specifications Function: For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. Features: - - (1/2" (15mm) thru 2" (50mm)) Flared edges ease installation for all pipe 44 types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. '.. (21/2" (65mm) thru 8" (200mm)) Spring tension on nut holds it securely in ," hanger before installation. Adjusting nut is easily removed. Approvals: Underwriters Laboratories listed (1/2" (15mm) thru 8" (200mm)) B c' in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Fig. 200-1 to 200-2 A Factory Mutual Engineering Approved 0/4" (20mm) thru 8" (200mm)). Conforms to Federal Specifications WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Fig. 200-/2. 200-/4 Maximum Temperature: 650°F (343°C) Fig. 200.21/2 to 200-8 Finish: Pre-Galvanized. Stainless Steel materials will be supplied with (2) hex nuts in place of a knurl nut. Order By: Figure number and pipe size Designed to meet or exceed requirements of FM DS 2-0. 200M8-1/2 1/2" (15) MB 31/8' (79.4) 2I8" (66.7) 11 (5.0) 200M10-1/2 1/2" (15) M10 31/8" (79.4) 2/8" (66.7) 11 (5.0) 200M8-3/4 3/4" (20) M8 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200M10-3/4 3/4" (20) M10 31/8" (79.4) 21/2' (63.5) 11 (5.0) 200M8-1 1° (25) M8 3/8" (85.7) 2I8" (66.7) 12 (5.5) 200Mb-1 1" (25) M10 3I8" (85.7) 25/8" (66.7) 12 (5.5) 200M8-11/4 11/4" (32) M8 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M10-11/4 11/4 (32) M10 33/4" (94.0) 2/8" (73.0) 13 (5.9) 200M8-11/2 11/2" (40) M8 3/8" (98.4) 27/8" (73.0) 14 (6.4) 200M10-11/2 11/2" (40) M10 3I8" (98.4) 2/8" (73.0) 14 (6.4) 200M8-2 (50) M8 41/2" (114.3) (76.3) 15 (6.9) 200M10-2 211 (50) M10 41/2" (114.3) 3" (76.3) 15 (6.9) 200M-21/2 21/2 ' (65) M10 5/8" (142.9) 41/8" (104.7) 27 (12.3) 200M-3 3° (75) M10 5/8" (149.1) 4" (101.6) 29 (13.3) 200M-31/2 31/2" (90) M10 7 /8" (187.3) 51/4" (133.3) 34 (15.6) 200M-4 4" (100) M10 7 /8" (187.3) 5" (127.0) 35 (16.0) 200M-5 (125) M12 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200M-6 (150) M12 101/8" (257.2) 6/4" (171.4) 73 (33.4) 200M-8 8" (200) M12 131/8" (333.4) 8/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. ;. -'.. :• COOPER B-Line Fig. 200H - Heavy Duty Band Hanger (For Trapeze) Size Range: 2" (50mm) thru 4" (1 00mm) trapeze pipe size. Material: Steel - Pre-Galvanized to G40 Spec Function: Designed primarily to support substantially heavier loads than is normally intended for the nominal hanger size. Used extensively to support trapeze installations and the increased loads from both above and below the trapeze assembly. Features: Furnished with /8"-16 or 1/2°_13 adjusting threaded ring nut. Approvals: Underwriters Laboratories listed in the USA (UL) and Canada** (cUL). Conforms to Federal Specification WW-H-171 E & A-A-1 192A, Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69 & SP-58, Type 10. Maximum Temperature: 650°F (343°C) Finish: Pre-Galvanized Order By: Figure number, pipe size and rod size. Important Design Note. Because of the increased loads applied to the trapeze assembly, both the upper trapeze supports as well as the lower hanging unit must be able to hold the maximum loads intended. TT 200H-2-3/8 211 (50) I8"-16 4/16" (115.9) 3/32" (81.7) 48 (21.8) 200H-2-1/2 2° (50) 1/2°_13 423/32' (119.8) 3/8' (85.7) 45 (20.4) 200H-21/2-3/8 21/2" (65) /8"-16 5/16' (134.9) 323/32" (94.4) 59 (26.7) 200H-21/2-1/2 21/2" (65) 1/2"_13 515/32 (138.9) 3/8" (98,3) 56 (25.4) 200H-3-3/8 311 (75) /8'-16 53/4 (146.0) 327/32 (97.6) 63 (28.6) 200H-3-1/2 3" (75) /2"13 5/8" (148.1) 331/32' (100.8) 60 (27.2) 200H-4-3/8 4" (100) /8"-16 6/8' (174.6) 4/16' (112.7) 76 (34.5) 200H-4-1/2 4" (100) 1/2"_13 71/32 (178.6) 1 419/32' (1116.7) 1 73 (33.1) * Select trapeze pipe size based on section modulus required for span of trapeze per information provided in NFPA 13. ** All sizes are UL Listed to support up to 8" pipe at max spacing per NFPA 13. For 6" (150mm) and 8" (200mm) trapeze pipe, consult factory. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified I COOPER B-Line Description LubeFit® is a vegetable fiber based lubricant for all gasketed fittings, including grooved couplings for fire sprinkler systems. It is non staining* and does not support bacterial growth. LubeFit® can be easily applied in temperatures from -10°F to 150°F. LubeFit® is non-toxic and water soluble. Under normal conditions, LubeFit® is not harmful to the skin. Design Criteria/Data Water dispersible Applies equally well to wet or dry surfaces Suitable for all types of pipe lines, including potable water Excellent working range -100 to 1500 Will not support bacteria Will not deteriorate natural or Synthetic rubber, plastic gaskets or caston iron pipe FGG/BM/CZ' System Compatible Program* Certified to NSF/ANS/Std 61 -G 3 0 00K. SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. Application LubeFit® should be applied in an even and thin amount over the parts to be lubricated. Avoid applying excessive amounts. The best applicaion is achieved when applying by hand. Clean all dirt, burrs and foreign matter from the joint surfaces. Make certain the gasket is properly located. Apply an even coating of lubricant to all fitting surfaces and gasket. Assemble the joint according to the pipe fitting manufacturer's directions. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, fl ush with water for 5 minutes. If discomfort persists get medical attention. *Will stain untreated porous surfaces such as concrete if not cleaned from the surface immediately. Specifications Appearance: Dense, paste like consistency and is light brown or tan in color. Contains: Potassium Oleate, Propylene Glycol and Mica. Contains NO PETROLEUM. Packaging: 21b (1-quart approx.) 55-gi drum (400 lbs. approx.) See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com CAUTION: Eye irritant. Avoid contact with eyes. Wash thoroughly after use. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1 800 344-3775 WW © 2012 Fire Protection Products, Inc. FPPI®, LubeFit® are registered trademarks of Fire Protection Products, Inc. EGG/BM/CZ", Blaze-Master", FlowGuard Gold® and Coizan® are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. !FiTh!S!IiigPa!e F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. piperl The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or WOW defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50 f to 500 f. F 0 0 SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster, and Corzan® pipe and fittings. ii 3198 LIONSHEAD AVE CARLSBAD, CA 92010 - FAX® 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipef it® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com wu LA MADE IN U.S.A. © 2012 Fire Protection Products, Inc. FPPI, LubeFitA are registered trademarks of Fire Protection Products, Inc. FBC", BIazeMaster', FlowGuard Gold and Co,zan0 are registered trademarks of Noveon IP Holdings Corp. WWVWbtkiItbUJVI Spears® Compatible indicates that ThreadFit® CLEAR has been tested by Spears® Manufacturing to be compatible with Flameguard® pipe and fittings. SOL cautit,i 'irgiOl Description ThreadFit® CLEAR Thread Cutting Oil for Sprinkler Pipe is an excellent heavy duty, light colored cutting oil for all types of ferrous metal. It's special combination of anti-wear and anti-weld additives provides all the necessary lubricity and cooling modern pipe threading operations require. This balanced combination of additives will help improve die life and thread quality over other cutting oils and is Chlorine free. ThreadFit Clear's low smoke/ low odor formulation makes it ideal for use in high speed threading applications. L101 F P P I -U © 2013 Fire Protection Products, Inc. FPPI5, ThreadFit® are registered trademarks of Fire Protection Products, Inc. MADE IN U.S.A. Tj"O'r TT. Features Heavy Duty Cutting Oil Excellent Tool Life Chlorine Free All types of ferrous metal or pipe Improved Surface Finish Low Odor Low Smoke ENV;, SYSTEM COMPATIBLE *FBC System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSFIEAD AVE CARLSBAD, CA 92010 TEL +1 760 599-1168 + 1 800 344-1822 FAX + 1 800 344-3775 Installation ThreadFit® can be used in automatic and hand held applicators. Fill oil reservoir according to equipment manufacturers specifications. Mixing of different types of threading oils is not recommended. DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Change oil regularly for optimum performance. Contains petroleum oil. Avoid breathing mists or vapors. Avoid eye contact and prolonged or repeated contact with skin. Wear safety glasses or goggles. Use good personal hygeine. Dispose of used oil in accordance with all local, State and Federal ordinances and regulations. Consult Material Safety Data Sheets for additional safety and handling information. DO NOT MIX WITH OTHER THREAD CUTTING OILS OR CONTAMINANTS. Specifications Appearance: Clear amber liquid. Packaging: 1 gl. (6/case) 5 gl. Pail 55-gl drum 275-gl tote CAUTION: Skin contact: wash thoroughly with soap and water. Eye contact: flush eyes with water for at least 15 minutes and seek medical attention. Ingestion: consult a physician immediately. Inhalation: move affected person(s) to fresh air and seek medical attention. See MSDS for first aid instructions. Spill or Leak: Soak up with an oil absorbent compound. Follow all state, local, Federal regulations for disposal. Don't pollute. Conserve our resources-Please recycle this container. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com This product is registered with CHEMTREC, a 24-hour emergency hot/me. They may be reached at 1 800 424-9300.